Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS
|
|
- Gregory Chapman
- 6 years ago
- Views:
Transcription
1 Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS Authors: Conor Smith, Doug Fryer United Science Corp Furuby Rd. Center City, MN USA Abstract This application note describes the use of a quick, easy, cheap, effective, rugged, and safe (QuEChERS) AOAC sample preparation technique used in the extraction and cleanup of 16 pesticide residues in broccoli. The pesticides are all amenable to GC/MS analysis. The method involves the extraction of the pesticides from homogenized broccoli with a buffered aqueous/acetonitrile solvent system with partitioning using added salt. This is followed by cleanup using dispersive solid phase extraction (dspe) with CarbonX for QuEChERS (to remove pigments and sterols), PSA (to remove sugars, fatty acids, and organic acids), and MgSO 4 (to remove leftover water). The pesticides are then analyzed by GC/MS operating in selective ion monitoring (SIM) mode. The method was validated in terms of recovery and reproducibility. All pesticides were evaluated at 50 ng/g. The application produced excellent recoveries for all pesticides, including planar pesticides, without the need for the addition of toxic solvents such as toluene.
2 Reagents and Chemicals All reagents and solvents were high-performance liquid chromatography (HPLC) grade. Methanol (MeOH) was from sigma Aldrich, Acetonitrile (ACN) was from J&W, and glacial acetic acid (HAc) was from Ampresco. All pesticide standards were purchased from Sigma-Aldrich. Solutions and Standards A 1% acetic acid in ACN solution was prepared by adding 10 ml of HAc to 1 L of ACN. Standard stock solution (2 mg/ml) was made in MeOH and stored at -20 C. This solution was diluted to a spiking solution (5 µg/ml in MeOH) for use in the method. Sample Preparation The sample preparation procedure includes sample comminution, extraction and partitioning, and dispersive SPE clean-up. Two 15 g (±0.1 g) amounts of homogenized broccoli sample are placed into two 50 ml centrifuge tubes. For the spiked sample, 150 µl of spiking solution is added, and then the tube is vortexed for 30 seconds. Next, 15 ml of 1% Acetic Acid in ACN is added to each tube. Finally, an extract packet containing 6g of MgSO 4 and 1.5 g NaAcetate is added. (United Science P/N ) is added. Sample tubes are capped tightly, and hand-shaken vigorously for 1 min. Tubes are centrifuged at 4000 rpm for 5 min. Next, the ACN extracts are decanted into separate containers. The volume of ACN extracts (about 10 ml per extract) will be enough for multiple sample tests when using 2 ml dispersive SPE tubes (United Science P/N ). The 2 ml tubes contain 50 mg of PSA, 50 mg of CarbonX for QuEChERS, and 150 mg of anhydrous MgSO 4. We suggest vortexing the tubes for a few seconds before adding the sample, to prevent possible agglomerates. For both the spiked and unspiked extract, 1 ml is added to the 2 ml dspe tubes. At least three tubes are used for the unspiked extract so that there is sufficient cleaned up matrix for the matrix standard. The tubes are tightly capped and vortexed for 1 min. The 2 ml tubes are centrifuged with a micro-centrifuge at 13,000 rpm for 2 min. The spiked samples are then transferred directly into autosampler vials for GC/MS injection. For the matrix standard, 990 µl of cleaned up extract is added to a vial, followed by 10 µl of spiking solution. This mixture is then added into an autosampler vial for GC/MS injection. Recovery and Reproducibility The recovery and reproducibility are evaluated by spiking pesticide standards in comminuted broccoli sample at 50 ng/g. These samples were quantitated against a matrix standard. The ACN extract is spiked with microliter amounts of the pesticide mixture in MeOH. The standard is prepared by first removing the pigment through dspe with the CarbonX for QuEChERS, PSA, and MgSO 4 tube, followed by spiking of the resulting matrix blank. The analysis was performed in replicates of three (n = 3) at each level.
3 Instrument Condition An Agilent 5890 GC/MS was used for this study. GC conditions Inlet: Splitless Inlet liner: Agilent Ultra Inert splitless single taper wool p/n Carrier gas: Helium Inlet pressure: 19.6 psi (constant pressure mode) during run Inlet temperature: 250 ºC Injection volume: 1.0 µl Purge flow to split vent: 30 ml/min at 0.75 min Oven temperature program: 70 ºC (1 min), 50 ºC/min to 150 ºC (0 min), 6 ºC/min to 200 ºC (0 min), 16 ºC/min to 280 ºC (6 min) Column: Agilent J&W HP-5MS Ultra Inert 15 m 0.25 mm, 0.25 µm (p/n 19091S-431UI) MSD MS conditions Tune file: Atune.u Mode: SIM (refer to Table 1 for settings in detail) Source, quad, transfer line temperature: 230 ºC, 150 ºC and 280 ºC respectively Solvent delay: 2.30 min Multiplier voltage: Autotune voltage Table 1 SIM acquisition parameters used for the analysis of 18 pesticides by GC/MS Analyte SIM Collection window (min) RT (min) 1 Dichlorvos σ-Phenylphenol 170.1, Diazinon 137.1, Chlorpyrifos-methyl 285.9, Dichlorobenzophenone 250.0, Chlorpyrifos 196.8, Heptachlor epoxide 352.8, Folpet 259.9, γ-Chlordane 372.8, α-Chlordane 372.8, Dieldrin 262.9, DDE 245.9, Ethion Endosulfan sulfate Permethrin , Coumaphos 362.0,
4 ,6 15, * 11 8 Figure 1. GC/MS Chromatogram of 50 ng/g fortified broccoli sample extract processed with CarbonX dspe method. Peak identification: 1. Dichlorvos 2. Phenylphenol 3. Diazinon 4. Chloropyrifos-methyl 5. Dichlorobenzophenone 6. Chloropyrifos 7. Heptepoxide 8. Folpet 9. γ- Chlordane 10. α-chlordane 11. Dieldrin 12. DDE 13. Ethion 14. Endosulfan Sulfate 15. Permethrin 16. Coumaphos, * Internal Standard Atrazine.
5 Compound %Recovery %RSD Dichlorvos Phenylphenol Atrazine Diazinon Chlorpyrifos-methyl DCBP Chlorpyrifos Heptechlor Epoxide Folpet γ chlordane α chlordane Dieldrin DDE Ethion Endosulfan Sulfate Permethrin Coumaphos Recovery (%) Dichlorvos Phenylphenol Atrazine Broccoli Matrix with CarbonX for QuEChERS dspe Cleanup Figure 2. Pesticide recovery data for CarbonX at 50 ng/g. Note good recovery of planar pesticides Dichlorobenzophenone, Folpet, and Coumaphos without the need for additional solvents. Diazinon Chlorpyrifos-methyl DCBP Chlorpyrifos Heptechlor Epoxide Folpet γ chlordane α chlordane Dieldrin DDE Ethion Endosulfan Sulfate Permethrin Coumaphos
Methods for Increased Sample Throughput with Dirty Samples
Methods for Increased Sample Throughput with Dirty Samples Alan D Broske, Limian Zhao, and William H. Wilson Agilent Technologies, Inc. 1 Introduction GC inlet liner impacts sample transfer to the GC column
More informationApplication Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08)
Application Note: Multi-Residue Pesticides in Fruit and Vegetables (9/16/08) Product: DPX-Q (5 ml) INTRODUCTION The analysis of pesticides in fruit and vegetables is very important in the field of food
More informationSample Matrix Influence on GC/MS/MS Multiresidue Pesticide Analysis
Application Note Food Testing & Agriculture Sample Matrix Influence on GC/MS/MS Multiresidue Pesticide Analysis Author Jessica Westland Agilent Technologies, Inc. Abstract The complexity of pesticide analysis
More informationAccurately Identify and Quantify One Hundred Pesticides in a Single GC Run
Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run Application Note Author Jessica Westland Agilent Technologies, Inc. Abstract A selected target compound list of 195 various pesticides
More informationMultiresidue Pesticide Analysis with the Agilent Intuvo 9000 GC and Agilent 7000 Series Mass Spectrometer
Multiresidue Pesticide Analysis with the Agilent Intuvo GC and Agilent 7 Series Mass Spectrometer Application Note Author Rebecca Veeneman, PhD and Joan Stevens, PhD Agilent Technologies, Inc. Abstract
More informationA Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water
A Rapid Method for Trace Analysis of Organophosphorus Pesticides in Drinking Water Application Note Environmental Authors Min Cai and Yun Zou Agilent Technologies Co. Ltd, 412 Ying Lun Road Waigaoqiao
More informationANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER
ENVIRONMENTAL ANALYSIS ANALYSIS OF PESTICIDE RESIDUES IN DRINKING WATER AS PER BUREAU OF INDIAN STANDARDS USING THE AGILENT 7000 GC/MS/MS WITH PESTICIDES ANALYZER Solutions for Your Analytical Business
More informationOrganohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP1 and DB-CLP2
Organohalide Pesticides in Water by GC/µECD with Agilent J&W DB-CLP and DB-CLP Application Note Environmental Authors Doris Smith and Ken Lynam Agilent Technologies, Inc. Abstract Organohalide pesticides
More informationDetermination of Pesticide Residue in Vegetables Using the AutoMate-Q40. Application Note. Abstract. Introduction
Application Note Abstract Determination of Pesticide Residue in Vegetables Using the AutoMate-Q40 Page 1 QuEChERS is a Quick-Easy-Cheap-Effective-Rugged-Safe extraction method that has been developed for
More informationDetermination of Pesticide Residue in Apple Juice Using the AutoMate-Q40
Application Note Abstract QuEChERS is a Quick-Easy-Cheap-Effective-Rugged-Safe extraction method that has been developed for the determination of pesticide residues in agricultural commodities. While the
More informationApplication Note. Abstract. Authors. Environmental
Maintaining Compound Retention Times with the Backflush Enabled Pressure Controlled Tee Configuration for Agilent 7890A GCs with Agilent 5975 Series MSD and Agilent 7000 Series Triple Quadrupole MS Systems
More informationOlga Shimelis, Katherine Stenerson, Michael Ye, Carmen T. Santasania, and Ed Mauney. Supelco, Div. of Sigma-Aldrich, Bellefonte, PA USA
Method for Analysis of rganophosphorous Pesticides in Produce using Acetonitrile Extraction, Dual-Layer Carbon-Aminopropylsilica Cleanup and GC-NPD Detection lga Shimelis, Katherine Stenerson, Michael
More informationValidation Data for the Analysis of Chlorotalonil in Leek Using Mini-Luke Method Followed by GC-QqQ-MS/MS
Validation Data for the Analysis of Chlorotalonil in Leek Using Mini-Luke Method Followed by GC-QqQ-MS/MS CONTENTS 1. Aim and Scope 2 2. Short Description 2 3. Apparatus and Consumables 2 4. Chemicals
More informationPesticide Analysis in Drinking Water with Disk Extraction and Large Volume Injection
Pesticide Analysis in Drinking Water with Disk Extraction and Large Volume Injection A Residue Application for GC/MS/MS Triple Quadrupole Analysis Application Note Food Testing and Agriculture Authors
More informationMulti-Residue Pesticide Analysis in Ginseng Powder: Optimized Cleanup After QuEChERS Extraction for UPLC-MS/MS And GC-MS/MS Analysis
Multi-Residue Pesticide Analysis in Ginseng Powder: Optimized Cleanup After QuEChERS Extraction for UPLC-MS/MS And GC-MS/MS Analysis Michael S. Young, Kim Van Tran, and Jeremy C. Shia Waters Corporation,
More informationDetermination of chemical contaminants in marine fish by GCMS/MS using QuEChERS as an extraction method
PO-CON1550E Determination of chemical contaminants in marine fish by GCMS/MS using QuEChERS as an extraction method ASMS 2015 TP 338 Ankush Bhone, Durvesh Sawant, Dheeraj Handique, Prashant Hase, Sanket
More informationQ40. This automated platform will streamline the two part QuEChERS method from the liquid extraction through the cleanup.
Application Note Abstract With the rise in popularity of QuEChERS, due to its reliable multiresidue methods it has driven the need for automation of the QuEChERS extraction to increase productivity and
More informationTyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1
Application Note Method Validation of the AutoMate-Q40 for Pesticide Residues in Grapes Tyler Trent, Applications Sales Specialist; Teledyne Tekmar Page 1 Abstract The QuEChERS (Quick-Easy-Cheap-Effective-Rugged-Safe)
More informationEvaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis
Evaluating Inert Flow Path Components and Entire Flow Path for GC/MS/MS Pesticide Analysis Application Note Food Testing & Agriculture Author Limian Zhao Agilent Technologies, Inc. Abstract Flow path inertness
More informationImproving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing
Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing Application Note Environmental Author Chris Sandy Agilent Technologies, Inc. UK and Ireland Sales Headquarters
More informationAnalysis of Pesticide Residues in Lettuce Using a Modified QuEChERS Extraction Technique and Single Quadrupole GC/MS
Technical Note: 10222 Analysis of Pesticide Residues in Lettuce Using a Modified QuEChERS Extraction Technique and Single Quadrupole GC/MS Jessie Butler, David Steiniger, Eric Phillips, Thermo Fisher Scientific,
More informationAgilent Consumables Improve Performance with Shimadzu GC/MS
Agilent Consumables Improve Performance with Shimadzu GC/MS Application Note Environmental & Food Safety Author Ken Lynam Agilent Technologies, Inc. Abstract Leak-free performance over 150 heat cycles
More informationEVALUATION OF D DIFFERENT EXTRACTION METHODS OF PESTICIDE RESIDUES IN SPICES BY
EVALUATION OF DIFFERENT EXTRACTION METHODS OF PESTICIDE RESIDU UES IN SPICES BY LC-ToF-MS and GC-ToF-MS 1 Content 1. Aim and scope... 3 2. Short description... 3 3. 4. 5. 6. Consumables... 3 Chemicals...
More informationApplication Note. Abstract. Authors. Food Safety
Determination of Chloramphenicol, Florfenicol, and Thiamphenicol in Honey Using Agilent SampliQ PT Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note
More informationExtraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach
Extraction and Analysis of Neonicotinoid Pesticides using QuEChERS Approach Katherine K. Stenerson 1, Olga Shimelis 1, and Christine Dumas 2 1 Supelco, Div. of Sigma-Aldrich Bellefonte, PA 16823 USA 2
More informationAnalysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool
Analysis of Semivolatiles by GC/FID using the Ultra Inert Inlet Liners with Wool Application Note Environmental Authors Limian Zhao and Bill Wilson Agilent Technologies, Inc. 2850 Centerville Road Wilmington,
More informationOptimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System
Application Note Petrochemicals Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D50 on the Agilent 0 GC System Authors Jie Pan, Lukas Wieder,
More informationApplication Note. Abstract. Introduction. Experimental Instrument Conditions. Evaluation of Prohibited Dyes in Food : By An Automated Extraction
Application Note Abstract Evaluation of Prohibited Dyes in Food : By An Automated Extraction By: Tyler Trent P a g e 1 The Sudan dyes Sudan I, Sudan II, Sudan III and Sudan IV all belong to the compound
More informationValidated Multi-Residue Method for Extraction and Analysis of Trace-Level Pesticides in Surface Water Application
Validated Multi-Residue Method for Extraction and Analysis of Trace-Level Pesticides in Surface Water Application Environmental Authors Stephen Siegel and Mark Lee California Department of Food and Agriculture
More informationLarge Volume Injection of Organochlorine Pesticide Extracts Using a Programmable Temperature Vaporizer in the Solvent Split Mode
Application Note No. 028 Large Volume Injection of Organochlorine Pesticide Extracts Using a Programmable Temperature Vaporizer in the Solvent Split Mode Mark Krigbaum Abstract Programmed Temperature Vaporizers
More informationAppNote 1/2009 KEYWORDS ABSTRACT. Disposable Pipette Extraction (DPX), QuEChERS, Automation, Pesticides
AppNote 1/2009 Automated Multi-Residue Pesticide Analysis in Fruits and Vegetables by Disposable Pipette Extraction (DPX) and Gas Chromatography/Mass Spectrometry Hongxia Guan, William E. Brewer, Stephen
More informationDetermination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks
Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Jim Fenster, Julie McGettrick, Horizon Technology, Inc., Salem, NH Introduction Monocrotophos, Diazinon,
More informationPuzzled About LCMS? Sample. Sensitivity in Mass Spec Analysis. Prep. Adapting LC-UV. Optimizing and Maintaining Your Mass Spec LCMS
Puzzled About LCMS? Sensitivity in Mass Spec Analysis Sample Prep Adapting LC-UV Optimizing and Maintaining Your Mass Spec To LCMS Paul Altiero Alex Ucci Applications Phone Support Chemistry and Supplies
More informationRobustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety
Technical Overview Robustness of the Agilent Ultivo Triple Quadrupole LC/MS for Routine Analysis in Food Safety Authors Mark Sartain, Theresa Sosienski, and Dan Hui Dorothy Yang Agilent Technologies, Inc.
More informationExtraction and Dispersive Kits User Guide
Extraction and Dispersive Kits User Guide QuEChERS Kits Selection Chart... p. 3 AOAC 2007.01 Method Protocol... p. 4 EN I5662 Method Protocol... p. 5 Original Non-Buffered Protocol... p. 6 Ordering Information...
More informationA New Horizon of Performance Agilent G1888 Network Headspace Sampler
A New Horizon of Performance Agilent G1888 Network Headspace Sampler Full system integration Extended sample capacity Built-in ease-of-use Uncompromised reliability The Steps To Confidence From sample
More informationValidation Report 19
EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Validation Report 19 Determination of pesticide residues in oat, rye and wheat by GC-MS/MS and LC-MS/MS (QuEChERS
More informationMARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES
www.sge.com TECHNICAL ARTICLE MARKET FOCUSED - environmental ORGANOCHLORINE PESTICIDES With the widespread use of pesticides, especially over the last 40 years, pesticide analysis is one of the most universal
More informationExtraction of a Full Suite of Semivolatile Compounds from Drinking Water using Automated Solid Phase Extraction
Extraction of a Full Suite of Semivolatile Compounds from Drinking Water using Automated Solid Phase Extraction Melissa Lever, Horizon Technology, Inc., Salem, NH, USA Key Words US EPA 525.2, SPE, solid
More informationContract Laboratory Program (CLP) Pesticide Analysis with 0.18 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas. Application.
Contract Laboratory Program (CLP) Pesticide Analysis with 0.8 mm ID High-Efficiency GC Columns Utilizing Helium Carrier Gas Application Environmental Authors Ken Lynam and William Long Agilent Technologies,
More informationAnalytical Method of Limit Test for Hexachlorobenzene. in Picloram TC and Method Validation Data*
Analytical Method of Limit Test for Hexachlorobenzene in Picloram TC and Method Validation Data* Test Method (ABCTM-2010-01-07) 1. Apparatus Electronic Balance GC/MS System with NCI Ultrasonic Water Bath
More informationCHROMATOGRAPHY/MASS SPECTROMETRY
DETERMINATION OF 1,4-DIOXANE IN DRINKING WATER BY SOLID PHASE EXTRACTION (SPE) AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY (GC/MS) WITH SELECTED ION MONITORING (SIM)* EPA Method 522 Part Number: EU52112M6
More informationDrinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD. Application. Author. Abstract. Instrument Operating Parameters.
Drinking Water Semivolatiles Analysis using the 6890N/5975B inert GC/MSD Application Author Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808 USA Abstract The analysis
More informationOptimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools
Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools Application Note Abstract The Commonwealth of Massachusetts Department of Environmental Protection
More information- DisQuE Dispersive Sample Preparation
QuEChERS Procedure for Multi-Residue Pesticide Analysis - DisQuE Dispersive Sample Preparation INT RODUCTION The term pesticides is commonly used to describe a very broad class of crop-protecting chemicals,
More informationStandard Operation Procedure (SOP) for the Extraction and Instrument Analysis of Siloxanes from Cartridges
Standard Operation Procedure (SOP) for the Extraction and Instrument Analysis of Siloxanes from Cartridges Created March 17, 2016 Updated April 14, 2016 Dr. Rachel Marek (Asst. Research Scientist) 4105
More informationDetermination of Multiclass Pesticides in Dry Herbs Using GC-ECD
AENSI Journals Journal of Applied Science and Agriculture ISSN 1816-9112 Journal home page: www.aensiweb.com/jasa/index.html Determination of Multiclass Pesticides in Dry Herbs Using GC-ECD Sherif B. Abdel
More informationENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note
ENVIRONMENTAL ANALYSIS A TURN-KEY GUARANTEED ANALYSER FOR THE ROUTINE MEASUREMENT OF GLYPHOSATE AND AMPA IN DRINKING WATER (EUROPEAN DRINKING WATER DIRECTIVE 98/83/EC) AND OTHER ENVIRONMENTAL WATER SAMPLES
More informationA Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis. Application. Authors. Abstract.
A Direct Column-Performance Comparison for Rapid Contract Laboratory Program (CLP) Pesticide Analysis Application Environmental Authors Ken Lynam and John W. Henderson, Jr. Agilent Technologies, Inc. 2850
More informationVALIDATION OF A SCREENING METHOD FOR ANALYSIS OF 49 PESTICIDES IN FOODS OF PLANT ORIGIN
VALIDATION OF A SCREENING METHOD FOR ANALYSIS OF 49 PESTICIDES IN FOODS OF PLANT ORIGIN Ivan Lj. Milovanović 1*, Aleksandra Č. Mišan 1, Bojana M. Beljkaš 1 UDC 543.632 : 632.95 1 Institute for Food Technology,
More informationDirect Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing. Application. Author.
Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Deans Switch With Backflushing Application Environmental and Pharmaceutical Author Philip L. Wylie Agilent Technologies, Inc.
More informationMS Certified Vials. Pre-cleaned and certified vials for mass spectrometry
Pre-cleaned and certified vials for mass spectrometry The FIRST and ONLY pre-cleaned, low particle, low background chromatography vial When your instrumentation, sample handling and methodology is pushing
More informationAnalysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application
Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application Food Authors Frank David Research Institute for Chromatography Pres. Kennedypark
More informationMultipesticides Residue Determination in Fresh Okra Using QuEchERS Sample Preparation and Gas Chromatography Tandem Mass Spectrometry
Multipesticides Residue Determination in Fresh Okra Using QuEchERS Sample Preparation and Gas Chromatography Tandem Mass Spectrometry Application Note Food safety Authors Koushik Banerjee and Narayan Kamble
More informationAppNote 4/2006. Elimination of Non-Volatile Sample Matrix Components After GC Injection using a Thermal Desorber and Microvial Inserts KEYWORDS
AppNote 4/2006 Elimination of Non-Volatile Sample Matrix Components After GC Injection using a Thermal Desorber and Microvial Inserts Edward A. Pfannkoch, Jacqueline A. Whitecavage, Jack R. Stuff Gerstel,
More informationMethod of determination of phthalates by gas chromatography / mass spectrometry in wines
Method OIV-MA-AS323-10 Type IV methods 1. SCOPE This method applies to the detection and assay of phthalates in wines. 2. PRINCIPLE The sample is extracted using isohexane. The extract is concentrated
More informationAnalysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry
Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry Yang Shi, Catherine Lafontaine, and François A. Espourteille Thermo Fisher
More informationDetermination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018
Determination of Table 3 Compounds by LC/MS/MS Chemours Fluoroproducts Analytical Method Revision date: 4/26/2018 Instrument Setup (Note: Trapping column installed on Line A. Delay column installed between
More informationLC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices
Application Note Environmental LC/MS/MS Determination of PFOS and PFOA in Water and Soil Matrices Using an Agilent 19 Infinity II LC with Ultivo Tandem Mass Spectrometry Authors Wenlong Yang, Jing Guo,
More informationUnited States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science
CLG-MGCV2.01 Page 1 of 15 Contents A. INTRODUCTION... 2 B. EQUIPMENT... 2 C. REAGENTS AND SOLUTIONS... 3 D. STANDARDS... 4 E. SAMPLE PREPARATION... 5 F. ANALYTICAL PROCEDURE... 5 G. CONFIRMATION... 8 H.
More informationThe Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications
TECHNICAL BRIEF Gas Chromatography/ Mass Spectrometry The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications C 14 scans Introduction As gas chromatography
More informationDetermination of organochlorine pesticide residues in eggs by gel-permeation chromatography (GPC) cleanup and GC-ECD
Determination of organochlorine pesticide residues in eggs by gel-permeation chromatography (GPC) cleanup and GC-ECD 1. Experimental Section LabTech, Inc. 1.1 Instruments and reagents AutoClean automatic
More informationInterlaboratory Validation Study for the Analysis of Nitrosamines in Drinking Water using GC-MS/MS
Interlaboratory Validation Study for the Analysis of Nitrosamines in Drinking Water using GC-MS/MS Diana Wong, PhD National Environmental Monitoring Conference Washington, D.C. August 7, 2017 1 Outline
More informationBruce Morris*, Richard Schriner*, Rick Youngblood and Kim Gamble
Use of a Robotic Solid Phase Extraction Clean-up of QuEChERS Extracts to Give Improved Matrix Removal for Pesticide Residue Analyses by GC-MS/MS and LC-MS/MS. Bruce Morris*, Richard Schriner*, Rick Youngblood
More informationNitrosamines Analysis in Drinking Water Using GC/MS/MS Meeting Equivalence to EPA Method 521
Application Note Environmental Nitrosamines Analysis in Drinking Water Using GC/MS/MS Meeting Equivalence to EPA Method 521 Using Agilent 71 and 7 triple quadrupole GC/MS systems Authors Andy Eaton, Charles
More informationEPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace
EPA Method 524 for Determination of VOCs in Drinking Water Using Agilent 5975T LTM GC/MSD with Static Headspace Application Note Environmental Authors Xiaohua Li Agilent Technologies (Shanghai) Co., Ltd.
More informationAnalytical Method for aldrin, endrin and dieldrin (Targeted to Agricultural, Animal and Fishery Products)
Analytical Method for aldrin, endrin and dieldrin (Targeted to Agricultural, Animal and Fishery Products) The target compound to be determined is aldrin, endrin and dieldrin. 1. Instrument A gas chromatograph
More informationApplication Note. Abstract. Authors. Introduction. Environmental
EPA Method 538: Determination of Selected Organic Contaminants in Drinking Water by Direct Aqueous Injection with the Agilent 646 Triple Quadrupole LC/MS System Application Note Environmental Authors Imma
More informationConfirmation of THC in Oral Fluids Using High-Resolution 2-D GC/MS Application Note
Confirmation of THC in Oral Fluids Using High-Resolution 2-D GC/MS Application Note Forensic Toxicology Authors Dean F. Fritch, Ph.D., DABFT, DABCC-TC Orasure Technologies, Inc. 150 Webster Street Bethlehem,
More informationTechnical Article. Innovative Chromatography Solutions. The Rtx -CLPesticides Column Set Lets You Make the Choice
Technical Article Helium, Hydrogen, or Nitrogen The Choice is Yours: Unique Rtx -CLPesticides Column Set Provides Optimal Results for Organochlorine Pesticides GC-Micro-ECD Analysis Using Any Carrier Gas
More informationDETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS
DETERMINATION OF ORGANIC PRIORITY POLLUTANTS AND EMERGING COMPOUNDS IN WASTEWATER BY MICRO SOLID PHASE EXTRACTION COUPLED TO GCMS Prieto A 1, Schrader S 1, Moeder M 1, Lahoutifard N 2 1 Helmholtz-Center
More informationCurrent and future trends in Pesticide Residue analysis. Jim Garvey
Current and future trends in Pesticide Residue analysis Jim Garvey A brief history of Pesticide residue analysis Contents 1. Where we have come from 2. Where we are now 3. Where we are going Where we have
More informationOlefin Analyzer Solutions for Polymer Grade Ethylene and Propylene
Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene Angela Smith Henry Kelly Beard George Gonzalez 1 Impurity Monitoring in Olefin Production Analysis of contaminants in ethylene and propylene
More informationIntroducing a Rugged Core Method for GC/MS/MS Pesticide Residue Analysis
Introducing a Rugged Core Method for GC/MS/MS Pesticide Residue Analysis Offering New Reference Guide for Pesticide GC/MS/MS Analysis Katerina Mastovska Excellcon International LLC Developed by: Katerina
More informationDetermination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*
Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D* UCT Products: ECUNIPAH (ENVIRO-CLEAN Universal PAH/DRO 2000 mg/83 ml cartridge) Method Summary Method 8015D may be used
More informationAnalysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph
Analysis of USP Residual Solvents using the Agilent 797A Headspace Sampler with the Agilent 79B Gas Chromatograph Application Note Pharmaceuticals Authors Bart Tienpont, Frank David, and Pat Sandra
More informationMinimize Method Development Time for Pesticide Screening Using LC/MS Application Kit
Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit Dr. Jerry Zweigenbaum Senior Applications Scientist Food Safety Page 1 Agilent 1260 LC SampliQ Extraction and Dispersive
More informationAnalysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector
Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector Application Note Clinical Research Author Patrick Cronan Agilent Technologies,
More informationGC-MS (Multi-Residue) Screening for Pesticides; Emerging Organic Pollutants (EOP's) and Persistent Organic Pollutants (POP's).
GC-MS (Multi-Residue) Screening for Pesticides; Emerging Organic Pollutants (EOP's) and Persistent Organic Pollutants (POP's). The GC-MS Target Based Screening methods allow for virtually all GC-amenable
More informationAutomation for Improving the Workflows for LC-MS/MS. Francois Espourteille, Ph.D. Manager, Applications
Automation for Improving the Workflows for LC-MS/MS Francois Espourteille, Ph.D. Manager, Applications Discussion Overview Challenges of sample preparation in LC-MS analysis TurboFlow Technology Multiplexing
More informationApplication Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany
Quantification of trace-level herbicides in drinking water by online enrichment with the Agilent Infinity Series Online-SPE Solution and Triple Quadrupole MS Detection Application Note Environmental Author
More informationSimple Run Table Entry Cuts Sample onto Column 2. Method Developers Calculator to Tools correctly set flows and restrictor size
Introduction 2-D GC/MS and the Deans Switch: Theory and Applications Simplified 2-D GC can be used to accomplish the separation of specific analytes from very complex matrices. In complex sample matrices,
More informationGas Chromatography Assignment Chem 543/443
Gas Chromatography Assignment Chem 543/443 1. Introduction Capillary gas chromatography (GC) is one of the most popular analytical techniques used in today s research. Its popularity is mainly due to efficient
More informationTwo Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175
Two Headspace Solutions for the Analysis of Dissolved Gases in Water by Method RSKSOP-175 Application Note Abstract Dissolved gas analysis has been performed using a simplified headspace method following
More informationSpeedExtractor E-916 Extraction of Spices using the SpeedExtractor E-916 for the determination of Pesticides
064/2011 SpeedExtractor E-916 Extraction of Spices using the SpeedExtractor E-916 for the determination of Pesticides 064/2011 SpeedExtractor E-916 SHORT NOTE Extraction of Spices using the SpeedExtractor
More informationNew 7693 Autosampler and Multimode Inlet for Drinking Water Analysis
New 7693 Autosampler and Multimode Inlet for Drinking Water Analysis Easier Methods Development and Improved GC and GC/MS Sensitivity Mike Szelewski Agilent Technologies Wilmington,DE April 22, 2009 If
More informationEPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube
EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube Application Note Environmental Authors Don Noot, Ralph Hindle Vogon Laboratory Services Cochrane, AB
More informationTarget and Non-target Pesticide Residue Analysis Using GC/QQQ and GC/Q-TOF with a Discussion on Ways to Use Sandwich Injections
Target and Non-target Pesticide Residue Analysis Using GC/QQQ and GC/Q-TOF with a Discussion on Ways to Use Sandwich Injections Philip L. Wylie Agilent Technologies Wilmington, DE 1 Topics Target vs. Non-target
More informationEPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS
EPA Method 540: Selected Organic Contaminants Using Agilent Plexa Cartridges and the Agilent 6460 Triple Quadrupole LC/MS Application Note Environmental Authors Don Noot and Ralph Hindle Vogon Laboratory
More informationResolve Your Search for More Ions: The 5977B, 7000D, and 7010B GC/MS Instruments. Stephan Baumann ASTS Talk November, 2016
Resolve Your Search for More Ions: The 5977B, 7000D, and 7010B GC/MS Instruments Stephan Baumann ASTS Talk November, 2016 1 The Most Powerful EI GC/MS Source Ever Made. More intense electron beam NEW!
More informationAutomated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water. Pranathi R Perati Thermo Fisher Scientific, Sunnyvale, CA, USA
Automated Solid-Phase Extraction of Organochlorine Pesticides from Drinking Water Pranathi R Perati Thermo Fisher Scientific, Sunnyvale, CA, USA Overview A new method was developed to automate the capture
More informationOrganophosphorus Pesticides Residues in Cooked Capsicum annuum
A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 44, 2015 Guest Editors:RiccardoGuidetti,LuigiBodria, Stanley Best Copyright 2015, AIDIC ServiziS.r.l., ISBN 978-88-95608-35-8;ISSN 2283-9216 The
More informationThe Fast Track to Success. Pesticides Workflow Solutions for Intuvo GC/TQ
The Fast Track to Success Pesticides Workflow Solutions for Intuvo GC/TQ Pesticide and Environment Pollutants Screening from Start to Finish Time is money, and starting up a new laboratory, analysis,
More informationLow-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator
Application Note 25370206 Low-level Detection of,, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator Keywords Eclipse Fuel Oxygenates Methanol Model 4552 Purge and Trap Sample Concentrator
More informationOPTIMIZATION OF THE SWEEP CO-DISTILLATION CLEAN-UP METHOD FOR THE DETERMINATION OF ORGANOCHLORINE PESTICIDE RESIDUES IN PALM OIL
JOURNAL Journal of OF Oil OIL Palm PALM Research RESEARCH Vol. 16 (2) 16 No. 2, December 2004, p. 30-36 OPTIMIZATION OF THE SWEEP CO-DISTILLATION CLEAN-UP METHOD FOR THE DETERMINATION OF ORGANOCHLORINE
More informationQuality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC
Quality-by-Design-Based Method Development Using an Agilent 129 Infinity II LC An Efficient Method Development Workflow Combined with ISET-mediated Method Transfer Under Waters Empower 3 CDS Control Application
More informationPesticide Analysis in a Complex Matrix using a 2D GC/MS System
Welcome to our E-Seminar: Pesticide Analysis in a Complex Matrix using a 2D GC/MS System Slide 1 Multidimensional (2-D) GC Very old (>25 yrs) but powerful separation technique Based on cutting peak(s)
More informationAnalysis of Drinking Waters for a Suite of Pesticides using GC with dual ECD (US EPA Method 508.1) after SPE Concentration
Analysis of Drinking Waters for a Suite of Pesticides using GC with dual ECD (US EPA Method 508.1) after SPE Concentration Eric Scott and Keith Ewing, Kentucky Department for Environmental Protection,
More informationAmy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1
Application Note US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e 1 Abstract US EPA Method 8260 in conjunction
More informationValidation Report 16
EURL for Cereals and Feeding stuff National Food Institute Technical University of Denmark Validation Report 16 Determination of pesticide residues in wheat, barley and rice by GC-MS/MS and LC-MS/MS (QuEChERS
More information