QA Test Report VITA-350. (Product Reliability Test) Charles Chang Manager of QA Department. Knight Hu Test Engineer. Jeff Yang Approval

Size: px
Start display at page:

Download "QA Test Report VITA-350. (Product Reliability Test) Charles Chang Manager of QA Department. Knight Hu Test Engineer. Jeff Yang Approval"

Transcription

1 ISO-9001 Certified ISO Certified ISO Certified ADVANTECH CO., LTD. QA Test Report VITA-350 (Product Reliability Test) Report No : 07S092A1 Report Date : January 10, 2008 Issue Stamp Charles Chang Manager of QA Department Jeff Yang Approval Knight Hu Test Engineer

2 VITA-350 Table of Contents Report No.07S092A1 1. History list Test item list 3 3. Product specification entry 4 4. Product configuration photo High temperature operation test 9 6. Low temperature operation test Power ON/OFF test Cold Start Test Humidity test High temperature/humidity storage test Low temperature storage test Thermal profile test Random vibration test Sine vibration test Package vibration test Package drop test Shock test. 53 1

3 VITA-350 History List Report No.07S092A1 Ver. Description Remark A0 The VITA-350 test report A1 Update test standard description of random vibration Page 30 test with typing error. 2

4 VITA-350 Test Item List Report No.07S092A1 Num. Test item Result Remark 1 High temperature operation test Passed 2 Low temperature operation test Passed 3 Power ON/OFF test Passed 4 Cold Start Test Passed 5 Humidity test Passed 6 High temperature/humidity storage test Passed 7 Low temperature storage test Passed 8 Thermal profile test Passed 9 Random vibration test Passed 10 Sine vibration test Passed 11 Package vibration test Passed 12 Package drop test Passed 13 Shock test Passed 3

5 VITA-350 Product Spec Entry Report No.07S092A1 Num Item Specification 1 I/O port External I/O 1 x Serial Port: RS-232 interface 1 x Reset Button 1 x Phoenix Type of Power Input Connector 1 x Phoenix Type of Digital I/O Connector Programmable Digital I/O 2 GPRS Module Siemens Power Modes Sleep mode at DRX = 2 DRX = 5 DRX = 9 IDLE mode at DRX = 2 GSM 850 1)4) EGSM 900 1)4) GSM 1800/1900 2)4) Data mode GPRS, (4RX, 1TX) GSM 850 1)4) EGSM 900 1)4) GSM 1800/1900 2)4) 3 GPS Specifications 16 Channel ANTARIS 4 Positioning Engine Supports Various Serial Protocols (NEMA, UBX, & RTCM) Supports Active Antenna Short Antenna and Open Circuit Power Brown-out Protection: No External Reset Hardware Needed Accuracy: Position 2.5m CEP 5.0m SEP Position DGPS/SBAS2 2.0m CEP 3.0m SEP 4 GSM/GPRS Specifications of Siemens MC55 Module 5 Weight 100g 6 Power supply 9~35 V DC Tri-band MC55 EGSM900 /GSM1800/1900 GPRS Multi-slot Class 10 GPRS Mobile Station Class B Download: Max Kbps Uplink: Max Kbps Coding scheme CS1-4 Internet Service TCP, UDP, HTTP, FTP, SMTP, POP3 4

6 VITA-350 Product Configuration Photo Report No.07S092A1 Photo I: VITA-350 right-front side view 5

7 VITA-350 Product Configuration Photo Report No.07S092A1 Photo II: VITA-350 left-rear side view 6

8 VITA-350 Product Configuration Photo Report No.07S092A1 Photo III: VITA-350 structure photo I 7

9 VITA-350 Product Configuration Photo Report No.07S092A1 Photo IV: VITA-350 structure photo II 8

10 VITA-350 High Temp. Operation Test Report No.07S092A1 Test Date : September 7, 2007 ~ September 8, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC Testing procedures Test Bb : Dry Heat Test Test Condition : 1. Test Temperature : Test Times : 24Hrs 3. Test Software : Receive GPRS and GPS signal from satellite and basic station 4. Test Environment Curve : Temp time Hrs 0:0 2:00 26:00 28:00 9

11 VITA-350 High Temp. Operation Test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets high temperature operation test. 10

12 VITA-350 Low Temp. Operation Test Report No.07S092A1 Test Date : September 11, 2007 ~ September 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : Test Times : 24Hrs 3. Test Software : Receive GPRS and GPS signal from satellite and basic station 4. Test Environment Curve : Temp Time Hrs 0:0 1:30 25:30 27:00 11

13 VITA-350 Low Temp. Operation Test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1.All system functions must be checked with appropriate testing programs and should pass the inspection. 2.The system should not have degradation in its performance. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets low temperature operation test. 12

14 VITA-350 Humidity Test Report No. 07S092A1 Test Date : September 7, 2007 ~ September 9, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Ca : Damp Heat steady state Test Test Condition : 1. Test Temperature : Test Humidity : 95% 3. Test Times : 48Hrs 4. Test Software : Receive GPRS and GPS signal from satellite and basic station 5. Test Environment Curve : Humidity % Temp 95% % Time Hrs 0:00 1:00 49:00 50:00 13

15 VITA-350 Humidity Test Report No. 07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button and cover slot should work properly without any interference. 2. All screws should be tightened up appropriately. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets humidity test. 14

16 VITA-350 Power ON/OFF Test ReportNo.07S092A1 Test Date : September 8, 2007 ~ September 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Ab : Cold Test IEC Testing procedures Test Bb : Dry Heat Test Test Condition : Condition I : 1. Test Temperature : Test Times : 72 Hrs Step: A. System power on, record the count number then system power off. B. After 2 minutes, system power on again. C. Recycle step A& B for 1000 times. 3. Number of test : 1000 times 4. Test Software : VITA-350 power on connect to terminal PC, ensure function is worked. 5. Test Environment Curve: Temp 25 Power ON Times iiiiiiiiiiii -20 Power OFF Time Hrs 0:00 72:00 15

17 VITA-350 Power ON/OFF Test ReportNo.07S092A1 Condition II : 1. Test Temperature : Test Times : 72Hrs Step: A. System power on, record the count number then system power off. B. After 2 minutes, system power on again. C. Recycle step A& B for 1000 times. 3. Number of test : 1000 times 4. Test Software : VITA-350 power on connect to terminal PC, ensure function is worked. 5. Test Environment Curve: Temp 70 Power ON Times iiiiiiiiiiii 25 Power OFF Time Hrs 0:00 72:00 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp Model : THS-D4S-100 Date of Calibration : 01/24/

18 VITA-350 Power ON/OFF Test ReportNo.07S092A1 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Test Data : Test temperature Test times Test Result times 1000 times pass times 1000 times pass Performance Criteria : Electronic function check: 1. It could not failure any time during 1000 times testing. 2. All system functions must be checked with appropriate testing programs and should pass the inspection. 3. The system should not have degradation in its performance. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 17

19 VITA-350 Power ON/OFF Test ReportNo.07S092A1 Test Result : There is no failure time during 1000 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets power on/off test. 18

20 VITA-350 Cold Start Test ReportNo.07S092A1 Test Date : September 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : Test Times : 8Hrs Step: A. System power off 4 hours. B. System power on, then 2 minutes later, system power off. C. After 10 minutes, system power on again. D. Two minutes later, system power off again. E. Recycle step C& D for 20 times. 3. Number of test : 20 times 4. Test Software : VITA-350 power on connect to terminal PC, ensure function is worked. 5. Test Environment Curve : Temp 25 Power ON Times iiii -20 Power OFF Time Hrs 0:0 1:00 5:0 10min 9:00 10:00 12:00 19

21 VITA-350 Cold Start Test ReportNo.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. 3. It could not failure any time during 20 times testing. Test Result : There is no failure time during 20 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets cold start test. 20

22 VITA-350 High temp./humi. Storage test Report No.07S092A1 Test Date : September 14, 2007 ~ September 15,2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Ca : Damp heat steady state test Test Condition : 1. Test Temperature : Test Humidity : 95% 3. Test Times : 24Hrs 4. Test Environment Curve : Humidity % Temp 95% % Time Hrs 0:00 1:00 25:00 26:00 21

23 VITA-350 High temp./humi. Storage test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K.SON. CO. LTD. Model : THS-DL4+/-150 Date of Calibration : 5/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be smooth, and no deformed parts found. 22

24 VITA-350 High temp./humi. Storage test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets high temperature and humidity storage test. 23

25 VITA-350 Low Temp. Storage Test Report No.07S092A1 Test Date : September 13, 2007 ~ September 14, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : Test Times : 24Hrs 3. Test Environment Curve : Temp Time Hrs 0:0 1:30 25:30 27:00 24

26 VITA-350 Low Temp. Storage Test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K.SON. CO. LTD. Model : THS-DL4+/-150 Date of Calibration : 5/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be smooth, and no deformed parts found. 25

27 VITA-350 Low Temp. Storage Test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets low temperature storage test. 26

28 VITA-350 Thermal Profile Test Report No. 07S092A1 Test Date : October 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Bb : Dry Heat Test Test Condition : 1. Test Temperature : Test Times : Each temperature 4 Hrs 3. Test EUT under box with no air flow ambient 4. Test Software : Receive GPRS and GPS signal from satellite and basic station Test Equipment : DATA LOGGER YOKOGAWA CO. LTD. Model : up-1800 S/N : 47XS0063 Date of Calibration : 9/12/

29 VITA-350 Thermal Profile Test Report No. 07S092A1 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately. Test Data : NUM Parts List Measurement Calculation SEPC Ublox LEA-4S Infineon PMB7850C M36WDT W9825G6CH M LUPXA255A Ambient

30 VITA-350 Thermal Profile Test Report No. 07S092A1 Test Result : Conclusion : 1. The system specification of thermal profile is 65 degree C. 2. There is no damage in electronic functions or degradation has not been found. 3. Performance is maintained with no incurable physical damage or degradation. Passed The VITA-350 meets thermal profile test. Photo: VITA-350 test photo 29

31 VITA-350 Random vibration operation test Report No.07S092A1 Test Date : October 17, 2007 Test Site : Integrated Service Technology Inc. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference MIL-STD-810F 514.5C-3 Testing procedures Test Condition : 1. Test Acceleration: X axis 1.62Grms, Y axis 2.05grms, Z axis 2.2Grms 2. Test Frequency : 5-500Hz 3. Test Axis : X, Y, Z axis 4. Test Time : 1hr per axis 5. Test Software : Receive GPRS and GPS signal from satellite and basic station 6. Test Vibration Curve : 30

32 VITA-350 Random vibration operation test Report No.07S092A1 31

33 VITA-350 Random vibration operation test Report No.07S092A1 Test Equipment : Vibration Simulator System SHINKEN G-0230N Shake system. S / N: SG-4345 Date of Calibration: 03/29/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button,covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be smooth, and no deformed parts found. 32

34 VITA-350 Random vibration operation test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets random vibration operation test. PHOTO I: VITA-350 Random vibration test Z axis 33

35 VITA-350 Random vibration operation test Report No.07S092A1 PHOTO II: VITA-350 Random vibration test Y axis 34

36 VITA-350 Random vibration operation test Report No.07S092A1 PHOTO III: VITA-350 Random vibration test X axis 35

37 VITA-350 Sine vibration non-operation test Report No.07S092A1 Test Date : September 27, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC Testing procedures Test Fc: Vibration sinusoidal Test Test Condition : 1. Test Acceleration: 2G 2. Test Frequency :5-500Hz 3. Test Axis : X,Y,Z axis 4. Test Time : 1Hr per axis 5. Test Vibration Curve : Acceleration 2G Displacement 4.4mm 5Hz 15Hz 500Hz 36

38 VITA-350 Sine vibration non-operation test Report No.07S092A1 Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model: 9363EM-600F2K-40N120 S / N: MC Date of Calibration: 09/12/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button,covers,slot can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be smooth,and no deformed parts found. 37

39 VITA-350 Sine vibration non-operation test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets sine vibration non-operation test. PHOTO I: VITA-350 Sine vibration test Z axis 38

40 VITA-350 Sine vibration non-operation test Report No.07S092A1 PHOTO II: VITA-350 Sine vibration test X axis 39

41 VITA-350 Sine vibration non-operation test Report No.07S092A1 PHOTO III: VITA-350 Sine vibration test Y axis 40

42 VITA-350 Package Vibration Test Report No.07S092A1 Test Date : September 27, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC Testing procedures Test Fh : Vibration broadband random test Test Condition : 1. Test PSD : 0.026G²/Hz (2.16Grms) 2. Test Frequency : 5-500Hz 3. Test Axis : X,Y and Z axis 4. Test Time : 30 minutes per axis 5. Test Curve : PSD 0.026g²/Hz Acceleration 2.16Grms -6db/oct 5Hz 100Hz 500Hz 41

43 VITA-350 Package Vibration Test Report No.07S092A1 Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model: 9363EM-600F2K-40N120 S / N: MC Date of Calibration: 09/12/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be smoothes, and no deformed parts found. 42

44 VITA-350 Package Vibration Test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 System meets package vibration test. PHOTO I: VITA-350 package vibration test Z axis 43

45 VITA-350 Package Vibration Test Report No.07S092A1 PHOTO II: VITA-350 package vibration test X axis 44

46 VITA-350 Package Vibration Test Report No.07S092A1 PHOTO III: VITA-350 package vibration test Y axis 45

47 VITA-350 Package drop Test Report No.07S092A1 Test Date : September 19, 2007 Test Site : Advantech QA Environment Lab Performed By: Knight Hu Purpose : The DVT test Test Standard : Reference Federal Standard 101 Method 5007 Testing procedure B Test Ea : Drop Test Test Condition : 1. Test Phase : One corner Three edges Six faces 2. Test High : 100cm 3. Package Weight : 600 g 4. Package Dimension : 25.5cm 18.0cm 6.0cm 5. Test Drawing : Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner 46

48 VITA-350 Package drop Test Report No.07S092A1 Test Equipment : Drop Tester Machine TOSHIDA SEIKI Co. LTD. Model : DT-100B Sample Configuration & Quantity Under Test : Using one VITA-350 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate programs and should pass the inspection. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the board enclosure must be smooth, and no deformed parts should be found. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. 47

49 VITA-350 Package drop Test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets package drop test. 48

50 VITA-350 Package drop Test Report No.07S092A1 PHOTO I: VITA-350 structure photo 49

51 VITA-350 Package drop Test Report No.07S092A1 PHOTO II: VITA-350 corner test photo 50

52 VITA-350 Package drop Test Report No.07S092A1 PHOTO III: VITA-350 edge test photo 51

53 VITA-350 Package drop Test Report No.07S092A1 PHOTO IV: VITA-350 face test photo 52

54 VITA-350 Shock Test ReportNo.07S092A1 Test Date : October 17, 2007 Test Site : Integrated Service Technology Lab. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC testing procedures Test Ea : Shock test Test Condition : Shock Acceleration 50G 1. Test condition : Operation, Receive GPRS and GPS signal from satellite and basic station 2. Test pulse shape : half sine wave 3. Test acceleration 50G, pulse duration 11 ms 4. Test method : six faces (front, rear, left, right, top & bottom side) three times per side 5. Test Curve : Half Sine Wave 11ms Pulse Duration time 53

55 VITA-350 Shock Test ReportNo.07S092A1 Test Equipment : LAB AUTO-SHOCK II 2432 Shock tester Serial Number : Date of Calibration : 03/29/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. Mechanical function check: 1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth,and no deformed parts should be found. 54

56 VITA-350 Shock Test ReportNo.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets shock test. 55

57 VITA-350 Shock Test ReportNo.07S092A1 PHOTO I: VITA-350 shock test for bottom side 56

58 VITA-350 Shock Test ReportNo.07S092A1 PHOTO II: VITA-350 shock test for top side 57

59 VITA-350 Shock Test ReportNo.07S092A1 PHOTO III: VITA-350 shock test for right side 58

60 VITA-350 Shock Test ReportNo.07S092A1 PHOTO IV: VITA-350 shock test for left side 59

61 VITA-350 Shock Test ReportNo.07S092A1 PHOTO V: VITA-350 shock test for rear side 60

62 VITA-350 Shock Test ReportNo.07S092A1 PHOTO VI: VITA-350 shock test for front side 61

TESTING / INSPECTION

TESTING / INSPECTION Reliability & Communication Testing Instruments KING DESIGN INDUSTRIAL CO., LTD. VIBRATION TEST LABORATORY 4F,NO. 3, Lane 270, Pei Shen Road Sec. 3, http: //www.kdi.tw Shen Keng Dist., New Taipei City,

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 38 Contact: Mr Steve Abraham Suttons Business Park Tel: +44 (0)118 9662724 Suttons Park Avenue Fax: +44 (0)118 9669023 Reading E-Mail:

More information

TEST REPORT. B&W International GmbH Junkendiek Ibbenbühren

TEST REPORT. B&W International GmbH Junkendiek Ibbenbühren 1 Cover Sheet TEST REPORT Project-No.: 17-8981 Test Specimen: Shipping Unit - - Client: B&W International GmbH Junkendiek 5 49479 Ibbenbühren Responsible Persons: Waldemar Masur (B&W International GmbH)

More information

Vibration & Shock Test Report

Vibration & Shock Test Report Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402.472.5880 Fax: 402.472.5881 Vibration & Shock Test Report Company: Contact: Crystal Group 850 Kacena

More information

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT Report No. :DH1706090005A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name

More information

AUGUST 14, 2006 TEST REPORT # RANDOM VIBRATION TEST SERIES PROBE SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC.

AUGUST 14, 2006 TEST REPORT # RANDOM VIBRATION TEST SERIES PROBE SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC. AUGUST 14, 2006 TEST REPORT #206271 RANDOM VIBRATION TEST 101377-000 SERIES PROBE 204130-036 SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC. APPROVED BY: MAX PEEL SENIOR FELLOW CONTECH RESEARCH, INC.

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK (Environmental & Electrical Product Test Laboratory) 15 Enterprise Way Aviation Park West Bournemouth Airport Christchurch Dorset BH23 6HH

More information

GPS Vehicle Tracker Specification VP-203GW

GPS Vehicle Tracker Specification VP-203GW GPS Vehicle Tracker Specification VP-203GW Content brief -------------------------------------------------------------------------------------------------------------------------------- 2 Product appearance------------------------------------------------------------------------------------------------------------

More information

AUGUST 18, 2008 TEST REPORT #208315A QUALIFICAITON TESTING PART NUMBERS ERF S-D-RA ERM S-DV-L SAMTEC, INC.

AUGUST 18, 2008 TEST REPORT #208315A QUALIFICAITON TESTING PART NUMBERS ERF S-D-RA ERM S-DV-L SAMTEC, INC. AUGUST 18, 2008 TEST REPORT #208315A QUALIFICAITON TESTING PART NUMBERS ERF8-050-01-S-D-RA ERM8-050-05.0-S-DV-L SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC. Contech Research

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 HERMON LABORATORIES 66 Hatachana Street (Postal Mail to P.O. Box 23) Binyamina, 3055001, ISRAEL Mr. George Shleimovich Phone: 972 4 6288 001 Email: mail@hermonlabs.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 QUALITECH 30 Hasivim Street Petah-Tikva 4959338, ISRAEL Teodor Weisz Phone: 972 3 926 6218 Email: Tedy.Weisz@ecitele.com Eli Avital Phone: 972 3 926 6170 MECHANICAL

More information

SEAC DISCRETE TWINAX CABLE TYPE QUALIFICATION TEST REPORT SEAC/SEAF SEAC TU-TU-2/SEAF L-06-2-RA-LP-TR

SEAC DISCRETE TWINAX CABLE TYPE QUALIFICATION TEST REPORT SEAC/SEAF SEAC TU-TU-2/SEAF L-06-2-RA-LP-TR Project Number: Design Qualification Test Report Tracking Code: 346584_Report_Rev_1 Requested by: Liam Parkes Date: 1/29/2015 Tech: Aaron Mckim Test Start: 8/15/2014 Test Completed: 1/19/2015 (Actual part

More information

L.A.B. Equipment, Inc.

L.A.B. Equipment, Inc. L.A.B. Equipment, Inc. Fundamentals of Packaging Package Testing Standards Why Test.? Customers Demand it High Return Rate Competitors have an edge by Testing Evaluate Material Suppliers Distribution Modes

More information

LABORATORY TEST REPORT

LABORATORY TEST REPORT Report : 12144 BAE Systems (Operations) Limited The Faraday Test Centre Marconi Way Rochester Kent ME1 2XX Telephone: 01634 203541 Facsimile: 01634 203647 TOTAL NUMBER OF PAGES:- 6 LABORATORY TEST REPORT

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY PORTLAND 1 5245-A NE Elam Young Pkwy Hillsboro, OR 97124 Sandra Frank Phone: 561-529-1488 Email: sandra.frank@element.com MECHANICAL

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Product Assessment & Reliability Centre Ltd Unit 4 Alverdiscott Industrial Estate Bideford Devon EX39 4LQ Contact: Mr Richard Tabor Tel: +44 (0)1237 421255 E-Mail: info@parctest.co.uk Website: www.parctest.co.uk

More information

Titre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION

Titre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION Date: May 13 th, 2011 ISSUE: 3 C PAGE: 1 / 18 Titre / Title HIGH RELIABILITY RF COAXIAL LOADS AND ATTENUATORS GENERIC SPECIFICATION Rédigé par / Written by Responsabilité / Responsibility Date Signature

More information

MAY 27, 2008 TEST REPORT # QUALIFICAITON TESTING PART NUMBERS ERF8-050-L-D-EM2 ERM L-DV SAMTEC, INC.

MAY 27, 2008 TEST REPORT # QUALIFICAITON TESTING PART NUMBERS ERF8-050-L-D-EM2 ERM L-DV SAMTEC, INC. MAY 27, 2008 TEST REPORT #208157 QUALIFICAITON TESTING PART NUMBERS ERF8-050-L-D-EM2 ERM8-050-05.0-L-DV SAMTEC, INC. APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR OF TEST PROGRAM DEVELOPMENT CONTECH

More information

Because People Rely on Your Products, Everyday, You can Rely on Us

Because People Rely on Your Products, Everyday, You can Rely on Us Because People Rely on Your Products, Everyday, You can Rely on Us testing Services Environmental Testing Shock & Vibration Testing ACCREDITED 503.1 & 503.2 Ohio and Michigan Laboratories csz testing services

More information

PCIEC/PCIE PCIEC EC-EC-AP/PCIE F-D-RA

PCIEC/PCIE PCIEC EC-EC-AP/PCIE F-D-RA Project Number: Design Qualification Test Report Tracking Code: 346583 _Report_Rev_2 Requested by: Liam Parkes Date: 1/15/2015 Tech: Qty to test: 14 Test Start: 10/31/2014 Test Completed: 12/9/2014 (Actual

More information

Ceramic PTC Thermistor: PSB Series

Ceramic PTC Thermistor: PSB Series Features. RoHS compliant 2. Voltage ratings: 40V ac to 560V ac 3. Resistance range:0~00ω 4. Stable over a long life 5. Operating temperature range: -0 ~ +85 C (V=Vmax) -25 ~ +25 C (V=0) 6. Agency recognition:

More information

June 14, TEST REPORT # Rev ºC MECHANICAL SHOCK THERMAL SHOCK. CGAT (7 FIN 2.0 Dia/.892 HT)

June 14, TEST REPORT # Rev ºC MECHANICAL SHOCK THERMAL SHOCK. CGAT (7 FIN 2.0 Dia/.892 HT) June 14, 2004 TEST REPORT # 204158 Rev 1.1 VIBRATION @ 125ºC MECHANICAL SHOCK THERMAL SHOCK CGAT29-0008 (7 FIN 2.0 Dia/.892 HT) CGAT29-0019 (5 Fin 2.0 Dia/.678 HT) CALGREG APPROVED BY: George G. Olear

More information

Balmer Lawrie & Co. Ltd LOGISTICS INFRASTRUCTURE

Balmer Lawrie & Co. Ltd LOGISTICS INFRASTRUCTURE Balmer Lawrie & Co. Ltd LOGISTICS INFRASTRUCTURE EXPRESSION OF INTEREST IS INVITED FROM LEADING VENDORS FOR PROVIDING A TOTAL SOLUTION ON Turnkey Project basis for supply, installation, design & development

More information

Environmental Testing

Environmental Testing Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402-323-NCEE (6233) Fax: 402-323-6238 Environmental Testing Company: Crystal Group 850 Kacena Road Hiawatha,

More information

High Current Thermal Fuse

High Current Thermal Fuse High Current Thermal Fuse FEATURES Functioning temperature: F = (235 ± 15) C Holding temperature: H = 160 C Current: 55 A Material categorization: For definitions of compliance please see www.vishay.com/doc?99912

More information

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere! JC Series High Performance Controllers...at the lowest prices anywhere! Structure Units available in standard DIN sizes (1/16, 1/8, and 1/4 DIN) NEMA 4X protective construction Black enclosure Programmable

More information

Transport of IGCT. The transportation of IGCT is classified according to IEC set IE22. Power and productivity for a better world

Transport of IGCT. The transportation of IGCT is classified according to IEC set IE22. Power and productivity for a better world Application te 5SZK 9110-00 Transport of IGCT The transportation of IGCT is classified according to IEC 60721-3-2 set IE22. Time limitation for transportation For the transportation by lorries and trailers

More information

Environmental Testing

Environmental Testing Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402-323-NCEE (6233) Fax: 402-323-6238 Environmental Testing Company: Crystal Group 850 Kacena Road Hiawatha,

More information

Technical Manual. NCC-20x. Network Control Center. Article No.: A A. Software version: V1.17 Document version: V3.

Technical Manual. NCC-20x. Network Control Center. Article No.: A A. Software version: V1.17 Document version: V3. Technical Manual NCC-20x Page 1 / 15 Technical Manual NCC-20x Network Control Center Article No.: 876 500 802A 876 500 803A Software version: V1.17 Document version: V3.3 Depending on the NCC software

More information

Ceramic PTC Thermistor: PPL Series

Ceramic PTC Thermistor: PPL Series Features 1. RoHS compliant 2. Two resistance-matched s in a plastic housing 3. Wide resistance range in telecom area from 10 to 50Ω 4. Compliant with ITU-T standards 5. Operating temperature range: 0 ~

More information

Design Objective

Design Objective Design Objective 108-115096 Low profile 5A battery connector 2015.03.03 REV:A 1.0 Scope: 1.1 Content: This specification covers the requirements for product performance, test methods and quality assurance

More information

MAY 22, 2006 TEST REPORT # RANDOM VIBRATION TEST SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC.

MAY 22, 2006 TEST REPORT # RANDOM VIBRATION TEST SERIES PROBE TEST SOCKET INTERCONNECT DEVICES, INC. MAY 22, 2006 TEST REPORT #206320 RANDOM VIBRATION TEST 100045-042 SERIES PROBE TEST SOKET INTERONNET DEVIES, IN. APPROVED BY: MAX PEEL SENIOR FELLOW ONTEH RESEARH, IN. ontech Research REVISION HISTORY

More information

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G Specifications ➊ Front of Panel (Operators) Mechanical Ratings Description Plastic (8EP/ES) Metal (8EM/EB) Vibration (assembled to panel) 1 2 Hz, 1.52 mm max./1 G max. Shock and no damage at 1 G Degree

More information

Ceramic PTC Thermistor: PSB Series

Ceramic PTC Thermistor: PSB Series Features. RoHS compliant 2. Voltage ratings: 40V ac to 560V ac 3. Resistance range:0~00ω 4. Stable over a long life 5. Operating temperature range: -0 ~ +85 C (V=Vmax) -25 ~ +25 C (V=0) 6. Agency recognition:

More information

Anecto Ltd. Ballybrit Business Park, Galway. Testing Laboratory Registration number: 175T

Anecto Ltd. Ballybrit Business Park, Galway. Testing Laboratory Registration number: 175T Anecto Ltd. Ballybrit Business Park, Galway Testing Laboratory Registration number: 175T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that B83 Testing & Engineering, Inc. 3040 West

More information

DESIGN QUALIFICATION TEST REPORT ECUE/UEC5 ECUE C1-FF-01-1/UEC H-D-RA-1-A

DESIGN QUALIFICATION TEST REPORT ECUE/UEC5 ECUE C1-FF-01-1/UEC H-D-RA-1-A Project Number: Design Qualification Test Report Requested by: Liam Parkes Date: 8/25/2016 Tech: Aaron McKim Test Start: 12/10/2015 Test Completed: 12/25/2015 DESIGN QUALIFICATION TEST REPORT ECUE/UEC5

More information

: Advantech Co., Ltd. : PIII PC/104 CPU Module

: Advantech Co., Ltd. : PIII PC/104 CPU Module Applicant Equipment Model : Advantech Co., Ltd. : PIII PC/104 CPU Module : PCM-3370F Contain Exhibit A Exhibit B Exhibit C Exhibit D Exhibit E Exhibit F Label Test Report User Manual Block Diagram Circuit

More information

THE KENYA POWER AND LIGHTING CO. LTD

THE KENYA POWER AND LIGHTING CO. LTD THE KENYA POWER AND LIGHTING CO. LTD SPECIFICATION For AUTOMATIC METER READING (AMR) METER DATA COLLECTOR Compiled by NAME DESIGNATION SIGNATURE DATE Ephantus Nyagah Ag. Senior Engineer, MCL. 31 st October

More information

Central Texas Electronics Association Electronics Design & Manufacturing Symposium February 22, 2011 IMPROVING SYSTEM RELIABILITY WITH SYNJET COOLING

Central Texas Electronics Association Electronics Design & Manufacturing Symposium February 22, 2011 IMPROVING SYSTEM RELIABILITY WITH SYNJET COOLING Central Texas Electronics Association Electronics Design & Manufacturing Symposium February 22, 2011 IMPROVING SYSTEM RELIABILITY WITH SYNJET COOLING Markus Schwickert [1] SynJet (Synthetic Jet) Operating

More information

SEMI Draft Document 5204 NEW STANDARD: Test Method for Mechanical Vibration of c-si PV Cells in Shipping Environment

SEMI Draft Document 5204 NEW STANDARD: Test Method for Mechanical Vibration of c-si PV Cells in Shipping Environment SEMI Draft Document 5204 NEW STANDARD: Test Method for Mechanical Vibration of c-si PV Cells in Shipping Environment 1 Purpose 1.1 For c-si technology, one of the problems is to identify and eliminate

More information

EC Type-Approval Certificate

EC Type-Approval Certificate EC Type-Approval Certificate No. DK 0199.365 Revision 3 MBC / MPE / MPD / MPC / MCC / MWA / MTA NON-AUTOMATIC WEIGHING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body

More information

Environmental Testing

Environmental Testing Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402-323-NCEE (6233) Fax: 402-323-6238 Environmental Testing Company: Crystal Group 850 Kacena Road Hiawatha,

More information

IRIS Serial Configuration for Galaxy Upload/Download Connections:

IRIS Serial Configuration for Galaxy Upload/Download Connections: IRIS Serial Configuration for Galaxy Upload/Download Connections: This document outlines the configuration for both the IRIS dialler and the Galaxy Panel required to perform upload/download over IP connections.

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION 1 of 23 B 1.0 GENERAL Scope This specification covers the insulation piercing Quickie Backplane Connector System designed for Backplane-to-flat cable (round conductor) interconnection in low power applications.

More information

Wireless Device Over the Air Performance Report

Wireless Device Over the Air Performance Report Wireless Device Over the Air Performance Report APPLICANT : Panasales Clearance Centre Pty Ltd T/A Cellsafe EQUIPMENT : radi chip BRAND NAME : cellsafe MODEL NAME : lif3 radi chip TEST DATE(S) : Aug. 25,

More information

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP Service Manual Imperial Series Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP Contents of Service Manual 1. Safety Precautions ------------------------------------------------------------------

More information

Draft EN V2.1.1 ( )

Draft EN V2.1.1 ( ) European Standard (Telecommunications series) Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-8: Specification of environmental tests;

More information

DURATEQ 3100 Conforms to MIL-STD 810F

DURATEQ 3100 Conforms to MIL-STD 810F DURATEQ 3100 Conforms to MIL-STD 810F Objective: Company Softeq Development Corporation Name of Case Study DURATEQ 3100 Passes MIL-STD 810F Testing Industry Hardware and Custom Software Development Solution

More information

JN FPC P CONNECTOR MANUFACTURER SIGNATURE

JN FPC P CONNECTOR MANUFACTURER SIGNATURE DOC. NO.: - ISSUE DATE: 20 / / CUSTOMER: PART NAME: PART NO.: FPC P CONNECTOR 1 APP. DATE: MANUFACTURER SIGNATURE P-TWO INDUSTRIES INC. NO. 9, SHIN HWA RD, KWEI SHAN IND. PARK TAOYUAN, 330 TAIWAN, R.O.C.

More information

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C

Data Bus Connector and Terminator Requirements Document DB-1001-A. Revision C Data Bus Connector and Terminator Requirements Document DB-1001-A Revision C 2507 W. Geneva Dr. Tempe, Arizona 85282 Phone [602] 231-8616 FAX [602] 273-9135 www.phxlogistics.com TABLE OF CONTENTS 1. Introduction

More information

HIGH VOLTAGE RESISTOR HVR

HIGH VOLTAGE RESISTOR HVR HIGH VOLTAGE RESISTOR FEATURES Metal film technology High pulse loading capability Small size Meeting safety requirements of: UL1676 (37 and 68, range 510 KΩ ~ 11 MΩ) - pending IEC 60065 EN 60065 VDE 0860

More information

Automotive Electronic Material Challenges. Anitha Sinkfield, Delphi

Automotive Electronic Material Challenges. Anitha Sinkfield, Delphi Automotive Electronic Material Challenges Anitha Sinkfield, Delphi Automotive Electronic Material Challenges Project Update About inemi Project Participants Problem Statement Project Details Summary and

More information

MARCH 17, 2009 TEST REPORT # REVISION 1.1 QUALIFICATION TESTING PART NUMBERS SEAF S-06-2-RA-GP SEAM S-06-2-GP SAMTEC, INC.

MARCH 17, 2009 TEST REPORT # REVISION 1.1 QUALIFICATION TESTING PART NUMBERS SEAF S-06-2-RA-GP SEAM S-06-2-GP SAMTEC, INC. MARCH 17, 2009 TEST REPORT #209070 REVISION 1.1 QUALIFICATION TESTING PART NUMBERS SEAF-50-01-S-06-2-RA-GP SEAM-50-02.0-S-06-2-GP SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH,

More information

TOUCH PANEL SPECIFICATION

TOUCH PANEL SPECIFICATION MULTI-INNO TECHNOLOGY CO., LTD. http:// www.multi-inno.com TOUCH PANEL SPECIFICATION Model : MI0970CAP-C Customer : Approved Commont Revision 1.0 Engineering Date 2012-10-05 Our Reference REVISION RECORD

More information

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kva. User Manual.

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kva. User Manual. The power behind competitiveness Delta UPS - Modulon Family DPH Series, Three Phase 200-500 kva User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and

More information

List of Environmental Test related MIL-STD-810 etc.

List of Environmental Test related MIL-STD-810 etc. 미국방규격및관련환경시험항목입니다. TEST Altitude Temperature/ Altitude Method applied ASTM D4169 14; DEF STAN 00 35, Part 3, Issue 4:2006: Chapter 3 09 Test CL9 Rapid and Explosive Decompression; GR 63 CORE, Issue 1 Paragraph

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer 316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) Variety of Pressure Ports and Electrical Connections DESCRIPTION The

More information

Through Hole Lamp Product Data Sheet LTL3H3ERADS Spec No.: DS Effective Date: 06/18/2013 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTL3H3ERADS Spec No.: DS Effective Date: 06/18/2013 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTL3H3ERADS Spec No.: DS20-2013-0021 Effective Date: 06/18/2013 Revision: - LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

Military Attenuator Module

Military Attenuator Module Military Attenuator Module Actual size: 2.28 x 2.4 x 0.5in 57,9 x 61,0 x 12,7mm MI-RAM Ripple Attenuator Module Features & Benefits Reduces output PARD to 10mVp-p Full attenuation up to 20A load No adjustments

More information

MAY-16 REV B2

MAY-16 REV B2 Product Specification 108-20025 06-MAY-16 REV B2 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity (TE)

More information

Operating Instructions. Electronics module. VEGAPULS series 60. Document ID: 36801

Operating Instructions. Electronics module. VEGAPULS series 60. Document ID: 36801 Operating Instructions Electronics module VEGAPULS series 60 Document ID: 36801 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used... 3 2 For your safety 2.1

More information

OVERVIEW OF PROCEDURE 2A

OVERVIEW OF PROCEDURE 2A Packaged-Products 150 lb (68 kg) or Less 2A 2 008 ISTA 2 Series Partial Simulation Performance Test Procedure VERSION DATE Last TECHNICAL Change: JANUARY 2008 Last EDITORIAL Change: JANUARY 2008 For complete

More information

Features. Rechargeable battery available. Advanced Power management. Up to 3 years without charging. Entry level product line available -

Features. Rechargeable battery available. Advanced Power management. Up to 3 years without charging. Entry level product line available - Family Product Line Construction Equipment Container Tracking Trailer Tracking Stolen Vehicle Recovery Advanced tracking and location based applications Select applications Cargo, Logistics & Asset Tracking

More information

DATA SHEET Metal Element Current Sensing Chip Resistor CLS Series

DATA SHEET Metal Element Current Sensing Chip Resistor CLS Series DATA SHEET Metal Element Current Sensing Chip Resistor 0.5% TO 5%, TCR ±25 TO ±450 SIZE: 1206/2010/2512/2725/2728/4527/4527S RoHs Compliant 14 October, 2016 V.4 DS-ENG-007 23 Page: 2 of 1. SCOPE 1.1 This

More information

Product Specification

Product Specification Product Name : AEM Part Number : Customer : Customer Revision: 2 Date: 2011-09-08 AEM Components (Suzhou) Co., Ltd 458 Shenhu Road, Suzhou Industrial Park Jiangsu, P.R China, 215122 TEL: 86-512-6258-0028

More information

SUMMARY OF INDEPENDENT ENVIRONMENTAL TESTING

SUMMARY OF INDEPENDENT ENVIRONMENTAL TESTING SUMMARY OF INDEPENDENT ENVIRONMENTAL TESTING Project Numbers: Equipment Tested: A7495-08274-30, 07527-30 07CA60582 Dell Latitude XFR D630 Environmental Test Dates: August 2007 January 2008 Independent

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PARAGON SYSTEMS 18 Basaltic Road Concord, Ontario, CANADA L4K 1G6 Tony Araujo Phone: 905 738 0447 x 237 tonya@paragonsystems.ca MECHANICAL Valid To: April 30,

More information

HOS LOW OHM POWER RESISTORS. SERIES Size As per AEC-Q Open frame strip type. 2W to 5W. R001 to R05.

HOS LOW OHM POWER RESISTORS. SERIES Size As per AEC-Q Open frame strip type. 2W to 5W. R001 to R05. SERIES Open frame strip type. 2W to 5W. R1 to R5. As per AEC-Q2 PHYSICAL CONFIGURATION L W H T D Recommended PCB layout for high precision applications : Kelvin (4 terminal pad design) is suggested as

More information

x15x3.5 MM SPEAKER. Features:

x15x3.5 MM SPEAKER. Features: 11x15x3.5 MM SPEAKER The 11 x 15 x 3.5 mm rectangular speaker is a high end miniature speaker specifically designed for portable devices, music phones and smartphones where high quality sound is required.

More information

Thermal Clamps Amphenol Series SIHD GT

Thermal Clamps Amphenol Series SIHD GT Thermal Clamps Amphenol Series SIHD GT MAIN CHARACTERISTICS MAXIMUM RELIABILITY QUICK LOCKING AND UNLOCKING : Unlike others on the market, Series SIHD- GT thermal clamps feature a quick, quarter-turn locking

More information

Draft EN V2.1.1 ( )

Draft EN V2.1.1 ( ) European Standard (Telecommunications series) Equipment Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests;

More information

Long-Range Reader/Writer

Long-Range Reader/Writer Features Read and Write to Dozens of Tags Simultaneously (Multiple-Tag-In-Field) Industrial Strength Reader/Writer (IP66) Large Read/Write Area International Recognized Frequency of 13.56 MHz RS422 Bus

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Manor Royal Crawley West Sussex RH10 9H Contact: Laura McLoughlin Tel: +44 (0) 1293 581824 E-Mail: laura.mcloughlin@uk.thalesgroup.com Testing

More information

Metal Additive Manufacturing Applied to VITA 48.2 Conduction-Cooled Single Board Computers

Metal Additive Manufacturing Applied to VITA 48.2 Conduction-Cooled Single Board Computers Metal Additive Manufacturing Applied to VITA 48.2 Conduction-Cooled Single Board Computers William VILLERS, Director of Engineering at TEN TECH LLC Abstract: Additive Manufacturing, and more specifically

More information

GSM/GPRS/GPS MINI TRACKER USER MANUAL

GSM/GPRS/GPS MINI TRACKER USER MANUAL GSM/GPRS/GPS MINI TRACKER USER MANUAL Preface Thank you for purchasing the Mini Gp s Tracker. This manual shows how to operate the device smoothly and correctly. Make sure to read this manual carefully

More information

GSM/GPRS/GPS MINI TRACKER USER MANUAL

GSM/GPRS/GPS MINI TRACKER USER MANUAL GSM/GPRS/GPS MINI TRACKER USER MANUAL Preface Thank you for purchasing the Mini Gp s Tracker. This manual shows how to operate the device smoothly and correctly. Make sure to read this manual carefully

More information

Environmental Testing

Environmental Testing Nebraska Center for Excellence in Electronics 4740 Discovery Drive Lincoln, NE 68521-5376 Phone: 402-323-NCEE (6233) Fax: 402-323-6238 Environmental Testing Company: Crystal Group 850 Kacena Road Hiawatha,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY DENVER 1530 Vista View Drive Longmont, CO 80504 Sandra Frank Phone 561 529 1488 MECHANICAL Valid To: July 31, 2018 Certificate

More information

PD662 LOOP-POWERED METER

PD662 LOOP-POWERED METER PD662 LOOP-POWERED METER 4-20 ma Input Loop-Powered -1999 to 2999 Display Easy Four-Button Programming NEMA 4X Enclosure Programmable Noise Filter Loop-Powered Backlight Option 1.7 Volt Drop without Backlight

More information

Mark R. Chrusciel. Director of Sales. For a copy of the slides

Mark R. Chrusciel. Director of Sales. For a copy of the slides Mark R. Chrusciel Director of Sales For a copy of the slides email: chrusciel@cszinc.com Who is CSZ? CSZ is a third generation family owned company which opened for business in 1940. The CSZ organization

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer 316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) Variety of Pressure Ports and Electrical Connections DESCRIPTION The

More information

Application of Metal Additive Manufacturing to Rugged Defense Electronics Systems

Application of Metal Additive Manufacturing to Rugged Defense Electronics Systems 1 Application of Metal Additive Manufacturing to Rugged Defense Electronics Systems William VILLERS, TEN TECH LLC imaps New England 45 th Symposium & Expo May 1 st 2018 1 Today s Discussion Introductions

More information

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER 4-20 ma input 1 V drop (4 V with Backlight) 3½ Digits LCD, 1" High Loop-Powered Backlight Option HART Protocol Transparent Plastic NEMA 4X, IP65 Enclosure

More information

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation

USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation USER MANUAL MODEL 1019 and 1019S DB-9 Async. Short Range Modem With Transformer Isolation C E R T I F I E D An ISO-9001 Certified Company Part# 07M1019-C Doc# 051021UC Revised 06/03/99 SALES OFFICE (301)

More information

EQJW 126: Heating controller with digital user interface, equitherm

EQJW 126: Heating controller with digital user interface, equitherm EQJW 126: Heating controller with digital user interface, equitherm How energy efficiency is improved Integrated automatic cut-off for the heating to save energy and convenient timer for programming the

More information

Through Hole Lamp Product Data Sheet LTL4DLGSAJ Spec No.: DS Effective Date: 07/09/2013 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTL4DLGSAJ Spec No.: DS Effective Date: 07/09/2013 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTL4DLGSAJ Spec No.: DS20-2013-0115 Effective Date: 07/09/2013 Revision: A LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

CHP Max5000 CONVERGED HEADEND PLATFORM

CHP Max5000 CONVERGED HEADEND PLATFORM CHP Max CHP Max5000 CONVERGED HEADEND PLATFORM Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged highdensity platform Investment protection through

More information

User Manual. Version 1.0 THERMISTOR CHARACTERISTICS TRAINER. Model No : (ITB - 06ACE)

User Manual. Version 1.0 THERMISTOR CHARACTERISTICS TRAINER. Model No : (ITB - 06ACE) THERMISTOR CHARACTERISTICS TRAINER Model No : (ITB - 06ACE) User Manual Version 1.0 Technical Clarification /Suggestion : / Technical Support Division, Vi Microsystems Pvt. Ltd., Plot No :75, Electronics

More information

Through Hole Lamp Product Data Sheet LTL4VMEPADS1 Spec No.: DS Effective Date: 10/05/2012 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTL4VMEPADS1 Spec No.: DS Effective Date: 10/05/2012 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTL4VMEPADS1 Spec No.: DS20-2012-0144 Effective Date: 10/05/2012 Revision: A LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer 316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) DESCRIPTION The D5100 series from Measurement Specialties sets the price

More information

Through Hole Lamp Product Data Sheet LTW-1CHDS4 Spec No.: DS Effective Date: 04/22/2014 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTW-1CHDS4 Spec No.: DS Effective Date: 04/22/2014 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet Spec No.: DS20-2014-0075 Effective Date: 04/22/2014 Revision: - LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung

More information

Testing Procedures Testing Procedures Parameter Test Tested according to Condition to be satisfied after testing AC/DC Bias Pulse Current Capability P

Testing Procedures Testing Procedures Parameter Test Tested according to Condition to be satisfied after testing AC/DC Bias Pulse Current Capability P Application Notes Testing Procedures SMD Soldering Recommendations 57 Testing Procedures Testing Procedures Parameter Test Tested according to Condition to be satisfied after testing AC/DC Bias Pulse Current

More information

Through-Hole Lamp Through Hole Lamp Rev Description Date Above data for PD and Customer tracking only

Through-Hole Lamp Through Hole Lamp Rev Description Date Above data for PD and Customer tracking only Through Hole Lamp Rev Description By Date P001 Preliminary SPEC Craig 06/12/2014 Above data for PD and Customer tracking only 1/9 Part No. : 1. Description 5mm round lamp is a popular design with a smooth

More information

EBI 10 High Precision Wireless Data Loggers

EBI 10 High Precision Wireless Data Loggers 8 Validation Data Loggers EBI 10 High Precision Wireless Data Loggers EBI 10 High Precision Wireless Data Loggers The Perfect Solution for Your Applications To fit each of your specific processes, ebro

More information

Through Hole Lamp Product Data Sheet LTL1NHTGT4TZP Spec No.: DS Effective Date: 08/11/2016 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTL1NHTGT4TZP Spec No.: DS Effective Date: 08/11/2016 LITE-ON DCC RELEASE Product Data Sheet Spec No.: DS20-2013-0151 Effective Date: 08/11/2016 Revision: B LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung Ho, New Taipei

More information

MMP - Metal Film MELF

MMP - Metal Film MELF Specifications Per IEC 60115-1, IEC 60115-2 EN140401-803 B L D Features SMD enabled structure Excellent solderability termination Products meet RoHS requirements and do not contain substances of very high

More information

Through Hole Lamp Product Data Sheet LTL1CHTBK5 Spec No.: DS Effective Date: 05/24/2012 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTL1CHTBK5 Spec No.: DS Effective Date: 05/24/2012 LITE-ON DCC RELEASE Through Hole Lamp Product Data Sheet LTL1CHTBK5 Spec No.: DS20-2002-455 Effective Date: 05/24/2012 Revision: F LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien

More information

Through Hole Lamp Product Data Sheet LTL-1NHGP6 Spec No.: DS Effective Date: 07/22/2016 LITE-ON DCC RELEASE

Through Hole Lamp Product Data Sheet LTL-1NHGP6 Spec No.: DS Effective Date: 07/22/2016 LITE-ON DCC RELEASE Product Data Sheet Spec No.: DS-20-99-0571 Effective Date: 07/22/2016 Revision: B LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung Ho, New Taipei

More information

IP/V24 WALLBOARD 2 x 16 digits TECHNICAL MANUAL AUTHOR DATE REFERENCE. V. Bafour 23/01/2008 D

IP/V24 WALLBOARD 2 x 16 digits TECHNICAL MANUAL AUTHOR DATE REFERENCE. V. Bafour 23/01/2008 D AUTHOR DATE REFERENCE V. Bafour Page 2/18 TABLE OF CONTENTS 1. INTRODUCTION... 3 2. SAFETY... 3 2.1 OPERATING REQUIREMENTS... 3 2.2 POWER SOURCE... 3 2.3 MAINTENANCE... 3 3. OVERVIEW... 4 3.1 REFERENCES...

More information