Lignite versus. bituminous GAC for biofiltration a case study

Size: px
Start display at page:

Download "Lignite versus. bituminous GAC for biofiltration a case study"

Transcription

1 The city of Wilmington, N.C., initiated a study to compare lignite granular activated carbon (GAC) to bituminous GAC for biofiltration at the city s surface water treatment plant. The plant uses conventional filtration with preozonation and intermediate ozonation to treat water from the Cape Fear River. For this study, the existing GAC media in two of the plant s full-scale dual-media filters was replaced one with lignite GAC and the other with bituminous GAC. The two new filters and one control filter containing the original GAC were operated BY ISSAM NAJM, MICHAEL KENNEDY, AND WILLIAM NAYLOR and monitored for 3 months. The first three months were used to exhaust the adsorptive capacity of the new GAC and biologically acclimate it. During the subsequent months, water quality samples were collected from various points throughout the treatment plant and from the effluent of each of the three filters. The samples were analyzed for various physical, chemical, and biological constituents. Quarterly GAC samples were also collected from each filter and analyzed for biomass content. The results indicated that the two types of GAC performed equally well in terms of removing turbidity, dissolved organic matter, color, assimilable organic carbon, and total aldehydes. The bacterial counts in the effluent of the two filters and on the GAC were also similar. Lignite versus bituminous GAC for biofiltration a case study T he Sweeney Water Treatment Plant (WTP) in Wilmington, N.C., treats Cape Fear River water using a series of water treatment processes that include ozonation and biofiltration. The biofiltration process serves two purposes: () it meets the filtration requirements for turbidity and filter run time, and (2) it removes organics via adsorption and biodegradation. The biofilters are dual-media filters with granular activated carbon (GAC) over silica sand. GAC was chosen over anthracite because it provides an additional barrier against chemicals that cause taste and odor in the water as well as greater surface area for bacterial attachment. The plant currently uses bituminous-based GAC, which has been in place since 997. The GAC has performed well for filtration and removal of the biodegradable organic matter (BOM). The city s water department was interested, however, in determining whether other types of GAC material would perform as well as or better than the bituminous GAC. If GAC made from other material performs as well in a biofiltration role, the city s options for GAC suppliers would increase substantially. To answer these questions, a side-by-side full-scale study was conducted to compare lignite GAC to bituminous GAC in a biofiltration mode. One benefit of lignite GAC over bituminous GAC is its lower density. This translates into a lower backwash water flow rate compared with bituminous GAC, which would in turn translate into savings in pumping energy and wasted water. This study was conducted between June 2 and. The objectives of the study were to 94 JANUARY 25 JOURNAL AWWA 97: PEER-REVIEWED NAJM ET AL

2 compare the performance of lignite GAC to that of bituminous GAC in terms of their ability to reduce the BOM concentration in the water, determine whether lignite GAC filters can be backwashed at a lower rate than bituminous GAC filters without compromising filter performance in terms of turbidity and BOM removal, and collect long-term operational data on the ability of both GAC types to meet the filtration requirements for turbidity removal and adequate filter run times. DESCRIPTION OF THE SWEENEY WTP Figure is a schematic of the Sweeney WTP. Water drawn from the Cape Fear River is first preozonated at a transferred dose ranging from 2 to 6 mg/l. The water then splits between two trains a south plant and a north plant. The south plant is a 5-mgd (57-ML/d) conventional coagulation, flocculation, and sedimentation train with intermediate ozonation and dual-media GAC/sand filtration. The north plant has a capacity of mgd (38 ML/d) and includes coagulation and high-rate clarification, followed by intermediate ozonation and dual-media GAC/sand filtration. The filtered waters from the two trains then combine into the plant s clearwell before entering the distribution system. After preozonation, caustics, lime, or both are added to each train to raise the alkalinity of the water before coagulation. Alum and cationic polymer are then added at the rapid mix of each train. Intermediate ozone is used to meet the primary disinfection requirements of.5-log Giardia and 2-log virus inactivation. The transferred intermediate ozone dose varies with water quality and can range from.5 mg/l to >6 mg/l. Caustics, lime, or both, along with chlorine, phosphate, and fluoride are then added to the combined filter effluents from the south and north plants. Additional chlorine is added to the clearwell effluent before the point of entry to the distribution system. DESCRIPTION OF TESTING PROGRAM The testing program described in this article was conducted at the south plant (Figure ), which contains 2 dual-media GAC/sand filters. The GAC in the filters, which was installed in 997, is bituminous-based. In June 2, the GAC was removed from two of the filters (filters and 2) and replaced with fresh GAC. The GAC in filter was replaced with bituminous-based GAC 2 and that in filter 2 was replaced with lignite-based GAC. 3 FIGURE General schematic of the Sweeney water treatment plant Polymer Alum Caustic or lime Preozone Caustic or Lime Alum Polymer South Plant 5 mgd (57 ML/d) Coagulation and high-rate clarification Filter, which contained the old(er) GAC media, was used as the control filter in the study. The characteristics of the media in all three test filters are listed in Table. The new bituminous GAC installed in filter was virtually identical to that in filter. The one noted difference in the lignite GAC installed in filter 2 was its smaller effective size, which was measured at.74 mm, compared with.9. mm for the bituminous GACs in filters and. After the new GAC was installed in filters and 2 in June 2, the filters were operated under normal conditions for three months in an effort to exhaust a large fraction of the adsorptive capacity of the new GAC and to biologically acclimate the new GAC filters. Beginning in and continuing through, a full-scale monitoring program was conducted on filters,, and 2. In the rest of this article, filter is referred to as the control filter, filter as the bituminous filter, and filter 2 as the lignite filter. Table 2 lists the types and locations of the various parameters monitored in this study along with their mon- Flocculation Sedimentation Intermediate filtration GAC/sand ozonation Intermediate ozonation North Plant mgd (38 ML/d) GAC/sand filtration Caustic or lime Chlorine Phosphate Fluoride Chlorine Clearwell TABLE Characteristics of the filtration media in test filters,, and 2 Filter, Filter, Filter 2, Media Control Bituminous Lignite Sand Depth mm (in.) 35 (2) 35 (2) 35 (2) Effective size mm Uniformity coefficient Granular activated carbon Base material Bituminous, old Bituminous, new Lignite, new Depth mm (in.) 686 (27) 686 (27) 686 (27) Effective size mm Uniformity coefficient < NAJM ET AL PEER-REVIEWED 97: JOURNAL AWWA JANUARY 25 95

3 TABLE 2 Types, locations, and frequencies of parameters monitored in this study Type Parameter Location Frequency General water quality TOC, DOC, color, ph, alkalinity, Raw water; preozone effluent, settled water, Monthly parameters temperature, turbidity, filtered UV 254 intermediate ozone effluent, filter influent, absorbance, and HPC bacteria control filter effluent, bituminous filter effluent, and lignite filter effluent Operational parameters Chemical doses through the plant, Control filter, bituminous filter, and lignite filter Monthly as well as filter loading rate; filter backwashing rates and durations; and filter run time Biological parameters Aldehydes and AOC, control filter effluent, bituminous Monthly filter effluent, and lignite filter effluent Biomass density on the surface Three lateral locations at a depth of 52 mm Quarterly of the GAC (6 in.) below the surface of the media AOC assimilable organic carbon, DOC dissolved organic carbon, HPC heterotrophic plate count, TOC total organic carbon, UV 254 ultraviolet absorbance measured at 254-nm wavelength itoring frequency. General chemical and physical parameters were measured each month at various locations across the treatment train. Similarly, operational parameters were monitored monthly. These included the chemical doses at the plant as well as detailed filter run and backwashing information from the three test filters. Finally, and most important, biofiltration performance parameters were collected, including monthly filter influent and effluent samples, which were analyzed for aldehydes, assimilable organic carbon (AOC), and bacterial heterotrophic plate counts (HPC), as well as quarterly GAC samples, which were analyzed for biomass density on the surface of the media. The biomass samples were collected from three locations across each filter and about 52 mm (6 in.) below the surface of the media. ANALYTICAL METHODS As shown in Table 2, several water quality parameters were measured. Total organic carbon (TOC) and dissolved organic carbon (DOC) were measured using a TOC analyzer. 4 DOC samples were filtered TABLE 3 using a.45-µm filter paper. 5 The filter papers were prewashed with 3 ml of deionized water. After an additional 3 ml of deionized water was filtered through the paper, it was collected and used as a DOC blank that was subtracted from the sample DOC result. All DOC samples were acidified after filtration. Color was measured using a spectrophotometer, 6 and water ph was measured using a ph meter. 7 The alkalinity was measured using method 232B (Standard Methods, 998). Ultraviolet light absorbance at 254-nm wavelength (UV 254 ) was measured using the spectrophotometer. HPC bacteria were enumerated using method 925B (Standard Methods, 998) with standard plate agar. Aldehydes, AOC, and biomass concentrations were measured by a private laboratory. 8 The aldehydes were measured using modified method 6252 (Standard Methods, 995) and included formaldehyde, acetaldehyde, glyoxal, and methylglyoxal. AOC concentrations were measured using method 927 (Standard Methods, 995). AOC values are reported as micrograms per litre as carbon (C) based on the total of the P7 strain and the NOX strain. The biomass density measurement was not a standard method but was developed by the laboratory for this project. The method, which was adapted from LeChevallier and McFeters (99), included the following steps:. Thirty grams of drained GAC was mixed with 27 ml of sterile deionized water. 2. The sample was placed in a sonicator 9 and mixed manually every 3 s. 3. Sample aliquots were removed at 6, 7, 8, 9, and min after sonication began. Quality of Cape Fear River water as received at the Sweeney Water Treatment Plant during the study period (October 2 ) Parameter Average Minimum Maximum Total organic carbon mg/l Dissolved organic carbon mg/l Filtered UV 254 absorbance cm Specific ultraviolet absorbance L/(mg-m) Color Pt Co Alkalinity mg/l as CaCO ph Turbidity ntu Temperature o C 2 28 UV 254 ultraviolet absorbance measured at 254-nm wavelength 96 JANUARY 25 JOURNAL AWWA 97: PEER-REVIEWED NAJM ET AL

4 4. The aliquots were spread-plated onto R2A agar plates in duplicate by diluting the aliquots with sterile buffered water to obtain about 3 to 3 colonies per plate (Standard Method SM925C, 995). 5. The plates were incubated at 22 o C for at least four days and then counted. 6. Duplicate results were averaged, and the sampling time with the highest average count was used for reporting. TESTING RESULTS AND DISCUSSION Table 3 lists the values of key water quality parameters measured in raw Cape Fear River water as received at the plant. The water contains relatively high concentrations of TOC and color, with low alkalinity and ph. Depending on the local runoff conditions, the turbidity in Cape Fear River water ranged from a low of 3.5 ntu to a high of 73 ntu on the days when samples were collected. The water is generally warm, with an average temperature of 2 o C (68 o F). The lowest temperature recorded during the study was o C (52 o F), and the highest temperature was 28 o C (82 o F). Figure 2 shows a monthly timeline of the concentrations of DOC in the raw water, filter influent water, and the effluent waters from the three filters. Because of the high alum dose used at the plant (3 to 75 mg/l) and the low ph of coagulation (about 5.8), DOC removal with chemical clarification during the months of monitoring ranged from 46 to 68%, with an average of 55%. The average DOC concentration in the effluent of the control filter was 2. mg/l, and the average DOC concentration in the effluent of each of the bituminous and lignite filters was.9 mg/l. Using a paired t-test, the investigators determined that the difference between the DOC concentrations in the effluent of the two test filters was not statistically significant at the 95% confidence level (p =.67). Figure 3 shows a plot of the calculated DOC removal achieved across the three filters over time. The DOC removal ranged from about.2 mg/l in to about.2 mg/l in. This was likely caused by the significant decrease in the empty-bed contact time (EBCT) through the filters between (5 6 min) and (about min). This is discussed later in the article. A paired t-test was conducted between the DOC removal measured across the control filter and that measured across each of the test filters, as well as between the DOC removals across the two test filters. The p values were.28 between the control filter and the lignite filter,.32 between the control filter and the bituminous filter, and.67 between the lignite filter and the bituminous filter. These values suggest that there was no statistical difference in the DOC removal among all three filters at the 95% confidence level. This analysis also suggests that the reduction in the DOC concentration resulted mostly from biological activity and not adsorption because the control filter had certainly lost its adsorptive capacity by the time the test was conducted. FIGURE 2 Dissolved organic carbon concentration profile across the treatment plant DOC Concentration mg/l Raw water Control filter effluent FIGURE 3 Dissolved organic carbon removal measured across the three filters DOC Removed mg/l Figure 4 shows a timeline profile of the turbidity measured in the raw water, filter influent, and the effluent waters from all three test filters. Although conventional clarification maintained the filter influent turbidity just below. ntu, the effluent turbidity from all three test filters was around. Control filter effluent NAJM ET AL PEER-REVIEWED 97: JOURNAL AWWA JANUARY 25 97

5 FIGURE 4 Turbidity profile across the treatment plant FIGURE 5 Color profile across the treatment plant Turbidity ntu. Color Value Pt Co units. Raw water Control filter. Raw water Control filter. FIGURE 6 Filtration rate and resulting empty bed contact time values FIGURE 7 Run times for the three test filters Filtration Rate gpm/sq ft (mm/s) 4. (2.7) 3.5 (2.4) 3. (2.) 2.5 (.7) 2. (.3).5 (.). (.68).5 (.34). Filtration rate control filter Filtration rate bituminous filter Filtration rate lignite filter EBCT control filter EBCT bituminous filter EBCT lignite filter EBCT min Run Time h Control filter Bituminous filter Lignite filter EBCT empty bed contact time ntu throughout the monitoring program. Examining the profiles in Figure 4 shows that the three filters performed equally well in turbidity removal throughout the testing period. A paired t-test showed that the difference in the turbidity values between the lignite and bituminous filters was not significant at the 95% confidence level (p =.327). Figure 5 shows a plot of the color value measured in the raw water, the filter influent, and the effluent of the three filters (the color value in the filter influent water was not measured during the initial three months of the study). The upstream processes of ozonation and coagulation/sedimentation reduced the color from about 5 to 98 JANUARY 25 JOURNAL AWWA 97: PEER-REVIEWED NAJM ET AL

6 about 5.5 platinum cobalt (Pt Co) units. The color was further reduced from 5.5 to about 2. Pt Co through the filters. Similar to the other water quality parameters, there was no significant difference in the effluent color value at the 95% confidence level between the bituminous filter and the lignite filter (p =.645), between the lignite filter and the control filter (p =.447), and between the bituminous filter and the control filter (p =.). Figure 6 shows plots of the filtration rate and EBCT in the three test filters during the monitoring program. The EBCT values reported are for the entire media depth (GAC and sand). During the first half of the study, the filtration rate was quite low (about.34 mm/s [.5 gpm/sq ft]), which resulted in significantly high EBCT values (5 to 6 min). This was caused by two factors. First, the demand in the distribution system was low during the fall and winter seasons. Second, a high-rate filtration study was being conducted at the north plant at the same time this study was being conducted at the south plant. The high-rate study required the plant staff to maintain a high flow through the north plant, which resulted in a period of low flow through the south plant. During the second half of the study, however, the filtration rate was gradually increased until it was at its maximum design value of.7 mm/s (2.5 gpm/sq ft) in June and. This resulted in an EBCT value of about min in each filter. It is noted in Figure 6 that the three test filters were operated under the same filtration conditions. Figure 7 shows a plot of the filter run times for all three test filters during the study. For most of the runs, all filters were terminated based on the maximum run time criteria (about h) and not because of turbidity breakthrough or head-loss limitations. Operational issues resulted in differences in filter run times in November and. The study demonstrated, however, that the three filters could be operated to the same run times with no operational limitations. AOC removal across the filters is shown in Figure 8. The filter-influent AOC concentration ranged from a low of 526 µg/l as C in to a high of,9 µg/l as C in. The AOC concentrations in the effluent of the three test filters were virtually identical, averaging about 2 µg/l as C. Throughout the full monitoring period, all three filters achieved approximately the same AOC removal (about 75%). A paired t-test showed that the difference in the AOC values between the lignite and bituminous filter effluents was not significant at the 95% confidence level (p =.474). The total aldehydes in the filter influent water ranged from a low of 56 µg/l to a high of 52 µg/l (Figure 9). The concentrations of total aldehydes measured in the effluent of the three test filters were similar and ranged from a low of 2 µg/l to a high of 36 µg/l. On the basis of the results from individual months, all three filters equally removed an average of 75% of the total aldehydes present in the water. A statistical analysis was conducted using a paired FIGURE 8 Assimilable organic carbon removal across the three test filters AOC Concentration µg/l as C,4,2, Control filter effluent t-test, and it determined that the difference in aldehyde removal between the lignite and bituminous filters was insignificant at the 95% confidence level (p =.692). Figure shows a plot of the log of the biomass density measured on the surface of the GAC samples collected from the three test filters in, January 22,, and. The values plotted AOC assimilable organic carbon, C carbon FIGURE 9 Removal of total aldehydes across the three test filters Aldehydes Concentration µg/l Control filter effluent NAJM ET AL PEER-REVIEWED 97: JOURNAL AWWA JANUARY 25 99

7 FIGURE Biomass density on the surface of the granular activated carbon in the three test filters FIGURE Geometric mean heterotrophic plate count values across the treatment process train, Log Biomass cfu/g Control filter Bituminous filter Lignite filter November January 2 22 April 22 July 22 Geometric Mean HPC cfu/ml,, Raw Water Preozone Effluent Settled Water Intermediate Ozone Effluent Filter Influent Control Filter Effluent Bituminous Filter Effluent Lignite Filter Effluent HPC heterotrophic plate count represent the geometric means of the three samples collected from each filter, and the error bars shown represent the logs of the maximum and minimum values among each set of triplicate samples. The results show that seven months after the installation of the new GAC (i.e., by ), the biomass densities on the new GACs were still lower than that on the old(er) GAC (by about..5 logs). Nevertheless, the biomass densities on the new GACs were still quite high (± 6 cfu/g), which resulted in the high removals of AOC and aldehydes shown in Figures 8 and 9. After one year of exposure to the influent water, the biomass densities on the new GAC media were virtually identical to that on the old(er) GAC. Figure shows a plot of the TABLE 4 geometric mean HPC bacterial levels measured across the treatment train during the monitoring period. The monitoring results show that Surface wash the lack of a disinfectant residual in the flocculation and sedimentation Low-rate wash basins, along with the expected increase in AOC concentration after preozonation, resulted in a significant increase in HPC bacterial High-rate wash counts across those processes. The intermediate ozonation process Low-rate wash decreased those counts by about two orders of magnitude. The filter influent samples contained significantly lower HPC levels than the intermediate ozone effluent samples. This is likely attributed to the carryover of some ozone residual after the intermediate ozone contactor. Nevertheless, as a result of the biological activity in the three test filters, the HPC counts in the filtered waters from the bituminous and lignite filters contained about 25 cfu/ml; those collected from the control filter contained about 65 cfu/ml. FILTER BACKWASHING The Sweeney WTP staff uses a standard procedure, summarized in Table 4, for backwashing the plant fil- Filter backwashing procedures used in this study Parameter Control Filter Bituminous Filter Lignite Filter Duration min Rate gpm/sq ft (mm/s) 9.7 (6.6) 9.7 (6.6) 5.8 (3.9) Duration min Rate gpm/sq ft (mm/s) 3.9 (9.4) 3.9 (9.4).6 (7.2) Duration min Rate gpm/sq ft (mm/s) 9.7 (6.6) 9.7 (6.6) 5.8 (3.9) Duration min JANUARY 25 JOURNAL AWWA 97: PEER-REVIEWED NAJM ET AL

8 ters. Durations of the various components of the backwashing cycle were maintained the same for all three filters. However, because lignite GAC is slightly less dense than bituminous GAC (dry bulk density of 37 kg/m 3 [23 lb/cu ft] for lignite GAC versus 45 kg/m 3 [28 lb/cu ft] for bituminous GAC), and because the lignite GAC size used was smaller than the bituminous GAC, the backwash water velocity required to adequately agitate lignite GAC is lower than that required for bituminous GAC. In this study, the lignite filter was backwashed at a lower backwash rate than the control filter and the bituminous filter (both of which contained bituminous GAC). The low high low backwash rates for the lignite filter were mm/s ( gpm/sq ft), compared with mm/s ( gpm/sq ft) for the control filter and the bituminous filter. As discussed earlier in this article, the lower backwash velocity used for the lignite filter did not compromise its operation and effectiveness for either turbidity or BOM removal. No attempt was made in this study to determine whether the control filter and the bituminous filter could have also been backwashed at the lower rate without compromising their performances. At the lower backwash rate, each lignite filter backwash cycle used 33 m 3 (8,7 gal) of water less than that used by either the control filter or the bituminous filter. In addition, the city would incur lower pumping energy costs because of the lower backwash flow rates. SUMMARY AND CONCLUSIONS This full-scale operations and monitoring study compared the performance of lignite GAC to that of bituminous GAC for biofiltration at the Sweeney WTP in Wilmington, N.C. Over a -month period, water quality and operational parameters were monitored across the plant. AOC and aldehydes removals across the filters were monitored, and biomass concentration on the surface of the GAC was measured four times during the study. The results showed that lignite GAC and bituminous GAC performed equally well for turbidity removal and biofiltration. One possible advantage of lignite GAC is its lower density, which requires a lower backwash rate for effective backwashing. This translates into less backwash water usage and lower energy consumption. The lower density also results in fewer pounds of GAC required to fill the required filter volume, which translates into lower costs. For example, when the plant staff decides to replace the GAC in the 2 filters, it will require 275 m 3 (9,72 cu ft) of GAC. This translates into 2 tons of lignite GAC (at 37 kg/m 3 [23 lb/cu ft]), but 36 tons of bituminous GAC (at 45 kg/m 3 [28 lb/cu ft]), a difference of approximately 8%. ACKNOWLEDGMENT This study was funded by NORIT Americas and the city of Wilmington, N.C. The authors thank the members of the Sweeney WTP s operations and laboratory staff for their hard work in collecting and analyzing the operational and water quality samples during the study. ABOUT THE AUTHORS Issam Najm (to whom correspondence should be addressed) is president and founder of Water Quality & Treatment Solutions, 8 Eddleston Dr., Northridge, CA 9326; (88) ; issam.najm@wqts.com. Najm is a member of AWWA, the International Water Association, and the American Chemical Society. He holds a BS degree in civil engineering from the American University of Beirut, Lebanon, and MS and PhD degrees in environmental engineering from the University of Illinois at Urbana- Champaign. In 99, AWWA presented Najm with its Best Doctoral Dissertation Award, and in 999, the University of Illinois Alumni Association awarded Najm its Young Civil Engineer Achievement Award. With 4 years of experience in evaluating and optimizing water treatment technologies, Najm is a registered professional engineer in California and also serves as an instructor of environmental engineering at the University of California, Los Angeles. Michael Kennedy is the plant supervisor of the Sweeney WTP, and William Naylor is a senior applications engineer with NORIT Americas. FOOTNOTES Superpulsator, Infilco Degremont, Richmond, Va. 2 NORIT GAC 83, NORIT Americas, Marshall, Texas 3 HYDRODARCO 3, NORIT Americas, Marshall, Texas 4 Dohrmann DC-8, Dohrmann, Santa Clara, Calif. 5 Pall Corp., Ann Arbor, Mich. 6 DR/4U, Hach Co., Loveland, Colo. 7 ATI Orion, Boston, Mass. 8MWH Laboratories, Monrovia, Calif. 9 Model 82, Branson, Danbury, Conn. REFERENCES If you have a comment about this article, please contact us at journal@awwa.org. LeChevallier, M., & McFeters, G., 99. Drinking Water Microbiology. Progress and Recent Developments. (G. McFeters, editor). Springer-Verlag, New York. Standard Methods for the Examination of Water and Wastewater, 995 (9th ed.). APHA, AWWA, and WEF, Washington. Standard Methods for the Examination of Water and Wastewater, 998 (2th ed.). APHA, AWWA, and WEF, Washington. NAJM ET AL PEER-REVIEWED 97: JOURNAL AWWA JANUARY 25

Dipti Shah, Town of Gilbert Tuesday, January 25, 2011

Dipti Shah, Town of Gilbert Tuesday, January 25, 2011 Dipti Shah, Town of Gilbert Tuesday, January 25, 2011 Background Treatment Plant Water Treatment Process Filter types Experiments Results Review Historical BAF /Non- BAF data Conclusion Recommendation

More information

Expanding Capacity and Treatment. Treatment Plant

Expanding Capacity and Treatment. Treatment Plant Dublin Road Water Plant Treatment Capacity Increase Project Expanding Capacity and Treatment at an 80 MGD Surface Water Treatment Plant Enoch Nicholson, P.E. S. Dean Ramsey, P.E. CH2M HILL Mark Eppich,

More information

SYSTEMATIC APPROACH TO WATER TREATMENT PLANT PROCESS OPTIMIZATION

SYSTEMATIC APPROACH TO WATER TREATMENT PLANT PROCESS OPTIMIZATION SYSTEMATIC APPROACH TO WATER TREATMENT PLANT PROCESS OPTIMIZATION Alex Yavich, Ph.D., P.E. Optimization Solutions Environmental, LLC WATERCON 2012 Optimization Solutions Environmental, LLC Water Treatment

More information

Comparing the Leopold Clari-DAF System to Upflow Contact Clarification

Comparing the Leopold Clari-DAF System to Upflow Contact Clarification JUST ADD WATER Comparing the Leopold Clari-DAF System to Upflow Contact Clarification James E. Farmerie Product Manager The F. B. Leopold Co., Inc. 227 South Division Street Zelienople, Pennsylvania 16063

More information

Amherst, MA, Drinking Water System

Amherst, MA, Drinking Water System Amherst, MA, Drinking Water System Atkins Water Treatment Plant Planned by: Ad Hoc Citizen s Advisory Committee, Amherst DPW and Consultant (Tighe & Bond, Inc) Water Source: Atkins Reservoir Design Flow:

More information

The City of West Palm Beach (City)

The City of West Palm Beach (City) FWRJ Pioneering Ultraviolet Treatment of Potable Water From High-Organic Surface Water in Florida Gabe Maul, GJ Schers, Poonam Kalkat, and Scott Kelly The City of West Palm Beach (City) plans to upgrade

More information

CEE 371 Water and Wastewater Systems

CEE 371 Water and Wastewater Systems Updated: 22 November 2009 CEE 371 Water and Wastewater Systems Print version Lecture #26 Atkins WTP: Plant Tour Reading: Handout (Dumais et al., 1994) David Reckhow CEE 371 L#26 1 Bus to Atkins WTP Pick

More information

WRF Webcast Biofilter Conversion Guidance Manual

WRF Webcast Biofilter Conversion Guidance Manual No part of this presentation may be copied, reproduced, or otherwise utilized without permission. WRF Webcast Biofilter Conversion Guidance Manual March 28, 2017 Biofiltration: Defining Benefits and Developing

More information

Another Tool in Our Toolbox

Another Tool in Our Toolbox BIOLOGICAL FILTRATION Another Tool in Our Toolbox Presented by: Grant L. Meyer, PE Surface Water Treatment Workshop May 2, 2018 BIOLOGICAL FILTRATION What is Biological Filtration? Why Consider Biological

More information

THIS POLICY DOES NOT HAVE THE FORCE OF LAW

THIS POLICY DOES NOT HAVE THE FORCE OF LAW THIS POLICY DOES NOT HAVE THE FORCE OF LAW Guidelines for evaluating granular activated carbon (GAC) for disinfection by-product (DBP) precursor removal Division: DDAGW Number: ENG-09-001 Category: Engineering-

More information

SIMPLE FILTER CAPPING APPROACHES FOR ENAHANCED BIOLOGICAL FILTRATION PERFORMANCE. Andrew WT Wong, EIT, University of Waterloo*

SIMPLE FILTER CAPPING APPROACHES FOR ENAHANCED BIOLOGICAL FILTRATION PERFORMANCE. Andrew WT Wong, EIT, University of Waterloo* SIMPLE FILTER CAPPING APPROACHES FOR ENAHANCED BIOLOGICAL FILTRATION PERFORMANCE Andrew WT Wong, EIT, University of Waterloo* Monica B Emelko, Ph.D., University of Waterloo Timothy Walton, A.Sc.T., Region

More information

Rapid Sand Filtration: Laboratory Analysis and Profiling

Rapid Sand Filtration: Laboratory Analysis and Profiling Rapid Sand Filtration: Laboratory Analysis and Profiling Rachel Easter & Rachael Osborne Water Bacteriologist-Chemist Division of Water Supply & Treatment City of Dayton Background Water Bacteriologist-Chemist

More information

Comparing Carbons for Disinfection Byproduct Control. Maggie H. Pierce, EI Sara N. Gibson, PE Mark M. Bishop, PE David S.

Comparing Carbons for Disinfection Byproduct Control. Maggie H. Pierce, EI Sara N. Gibson, PE Mark M. Bishop, PE David S. Comparing Carbons for Disinfection Byproduct Control Maggie H. Pierce, EI Sara N. Gibson, PE Mark M. Bishop, PE David S. Briley, PE Water JAM 2010 Overview Introduction Considerations for Granular Activated

More information

Submerged Membranes to Replace Media Filters to Increase Capacity 4X for a Small Community. Richard Stratton, PE HDR Engineering, Inc.

Submerged Membranes to Replace Media Filters to Increase Capacity 4X for a Small Community. Richard Stratton, PE HDR Engineering, Inc. Submerged Membranes to Replace Media Filters to Increase Capacity 4X for a Small Community Richard Stratton, PE HDR Engineering, Inc. Main Points of this Presentation Membranes can provide 4 times the

More information

DW Module 23: Organic Removal Answer Key

DW Module 23: Organic Removal Answer Key DW Module 23: Organic Removal Answer Key EXERCISE UNIT 1: Use the Word Box above to complete questions. Words used twice are indicated with a (2). Word Box Air Stripping (2) Adsorption (2) Boiling Carbon

More information

Civil Engineering Department

Civil Engineering Department Tanush Wadhawan 1, John McEvoy 2, and Eakalak Khan 1 1 Civil Engineering Department 2 Veterinary and Microbiological Sciences Department North Dakota State University Fargo, North Dakota USA Outlines Introduction

More information

PNW AWWA Conference 2009 Todd Reynolds, PE, BCEE

PNW AWWA Conference 2009 Todd Reynolds, PE, BCEE Startup and 1 st Year of Operation at the Ventura Avenue UF WTP PNW AWWA Conference 2009 Todd Reynolds, PE, BCEE Acknowledgements Aileen Kondo, Kennedy/Jenks Consultants Jim Passanisi and Mike Oakley,

More information

Renovation of the Filters at the Soldier Canyon Filter Plant in Fort Collins, Colorado

Renovation of the Filters at the Soldier Canyon Filter Plant in Fort Collins, Colorado JUST ADD WATER Renovation of the Filters at the Soldier Canyon Filter Plant in Fort Collins, Colorado Thomas M. Getting, P.E., DEE, Filtration Product Manager John Geibel, P.E., Chief Engineer Michael

More information

Improvement of Drinking Water Plant Treatment

Improvement of Drinking Water Plant Treatment Improvement of Drinking Water Plant Treatment A. ZOUBOULIS 1, *, G. TRASKAS 1 AND P. SAMARAS 2 1 Department of Chemistry, Division of Chemical Technology Aristotle University, Thessaloniki GR-541 24, Greece

More information

Innovative Improvements to a 53-Year Old Water Plant for HABs, Crypto, and Whatever Else the Maumee River Brings

Innovative Improvements to a 53-Year Old Water Plant for HABs, Crypto, and Whatever Else the Maumee River Brings Innovative Improvements to a 53-Year Old Water Plant for HABs, Crypto, and Whatever Else the Maumee River Brings Robert T. Shoaf, P.E., BCEE AECOM (Columbus, Ohio) Scott Hoover, Plant Superintendent Napoleon,

More information

Performance of GAC Filter-Adsorbers for Herbicide and DBP Control at Higginsville,, MO

Performance of GAC Filter-Adsorbers for Herbicide and DBP Control at Higginsville,, MO Performance of GAC Filter-Adsorbers for Herbicide and DBP Control at Higginsville,, MO Robert L. Segar Jr., Ph.D., P.E. Department of Civil and Environmental Engineering University of Missouri-Columbia

More information

Rinconada Water Treatment Plant Reliability Improvement Project (RIP) Filter Pilot Study

Rinconada Water Treatment Plant Reliability Improvement Project (RIP) Filter Pilot Study Rinconada Water Treatment Plant Reliability Improvement Project (RIP) Filter Pilot Study AWWA 2014 Fall Conference Lei Hong, Ph.D., P.E. Lale Guven, Environmental Engineer October 23, 2014 Presentation

More information

WRF Webcast Minimizing Waste Backwash Water from a Biological Denitrification Treatment System (project #4470)

WRF Webcast Minimizing Waste Backwash Water from a Biological Denitrification Treatment System (project #4470) No part of this presentation may be copied, reproduced, or otherwise utilized without permission. WRF Webcast Minimizing Waste Backwash Water from a Biological Denitrification Treatment System (project

More information

SECTION 6.0 DESIGN CRITERIA, LAYOUTS, & HYDRAULICS

SECTION 6.0 DESIGN CRITERIA, LAYOUTS, & HYDRAULICS SECTION 6.0 DESIGN CRITERIA, LAYOUTS, & HYDRAULICS This project focused on evaluating conventional ozone and Peroxone for meeting the Zone 7 T&O destruction goals. Conventional ozone refers to a standard

More information

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria

WEFTEC.06. Lake Okeechobee, Actiflo, peroxone, surface water, Cyanobacteria FRESH IDEAS FOR FRESH WATER: OKEECHOBEE UTILITY AUTHORITY S SURFACE WATER TREATMENT PLANT USES INNOVATIVE TECHNOLOGY TO ACHIEVE HIGH QUALITY DRINKING WATER FROM LAKE OKEECHOBEE By: Curtis Robinson, E.I.

More information

MAXIMIZING FILTRATION CAPACITY FOR PRODUCTION OF TERTIARY RECYCLED WATER

MAXIMIZING FILTRATION CAPACITY FOR PRODUCTION OF TERTIARY RECYCLED WATER MAXIMIZING FILTRATION CAPACITY FOR PRODUCTION OF TERTIARY RECYCLED WATER Bahman Sheikh, Gordon Williams, Kara Nelson, Bob Holden, Tom Kouretas, James Crook, Robert Cooper Abstract This paper summarizes

More information

Removing Algal Toxins from the Toledo Tap

Removing Algal Toxins from the Toledo Tap Removing Algal Toxins from the Toledo Tap Warren Henry City of Toledo Nick Burns Black & Veatch Agenda Lake Erie, 2011 Background on algal toxins Concerns Treatment Effectiveness Toledo Experience Summary

More information

Disinfection By-Products Reduction and SCADA Evaluation and WTP Sludge Removal System and Dewatering Facility

Disinfection By-Products Reduction and SCADA Evaluation and WTP Sludge Removal System and Dewatering Facility SOUTH GRANVILLE WATER & SEWER AUTHORITY Disinfection By-Products Reduction and SCADA Evaluation and WTP Sludge Removal System and Dewatering Facility Presentation to the SGWASA Board October 10, 2017 TTHM

More information

THIS POLICY DOES NOT HAVE THE FORCE OF LAW

THIS POLICY DOES NOT HAVE THE FORCE OF LAW THIS POLICY DOES NOT HAVE THE FORCE OF LAW GUIDELINES FOR TREATMENT PROCESS Division: DDAGW RATINGS AT PRECIPITATIVE (e.g.,lime) Number: ENG-02-001 SOFTENING GROUND WATER Category: Final TREATMENT PLANTS

More information

Siva Sarathy and Mihaela Stefan

Siva Sarathy and Mihaela Stefan Siva Sarathy and Mihaela Stefan Trojan Technologies, London, ON, Canada ssarathy@trojanuv.com Combination of UV and H 2 O 2 providing enhanced oxidative degradation of pollutants in water via highly reactive

More information

Cary/Apex Water Treatment Facility- Ozone Biofiltration Pilot Study

Cary/Apex Water Treatment Facility- Ozone Biofiltration Pilot Study Cary/Apex Water Treatment Facility- Ozone Biofiltration Pilot Study March 26, 2018 Judith Labrada Bill Dowbiggin, PE Agenda Project Background Project Drivers Why CAWTF considered a change? What is Ozone

More information

Process Treatment Selection and. Jeff Macomber, P.E. One Water Conference August 28, 2014

Process Treatment Selection and. Jeff Macomber, P.E. One Water Conference August 28, 2014 Process Treatment Selection and Design for the City of Piqua s New WTP Jeff Macomber, P.E. One Water Conference August 28, 2014 Agenda Project Background Water Treatment Goals Process Treatment Alternative

More information

FUNDAMENTALS OF GRANULAR MEDIA FILTRATION. Gordon Williams, PhD, PE East Bay Municipal Utility District

FUNDAMENTALS OF GRANULAR MEDIA FILTRATION. Gordon Williams, PhD, PE East Bay Municipal Utility District FUNDAMENTALS OF GRANULAR MEDIA FILTRATION Gordon Williams, PhD, PE East Bay Municipal Utility District 1 OVERVIEW Filtration basics Filtration theory Filter media selection and design Monitoring and Troubleshooting

More information

Validation Testing of a High Rate Disk Filter For Water Recycling Applications

Validation Testing of a High Rate Disk Filter For Water Recycling Applications Validation Testing of a High Rate Disk Filter For Water Recycling Applications PNCWA 2010 Keith Bourgeous, Nicola Fontaine, and Kathy Marks Testing Designed to Demonstrate Filtration Performance According

More information

WRF Webcast Optimizing Engineered Biofiltration (#4346)

WRF Webcast Optimizing Engineered Biofiltration (#4346) No part of this presentation may be copied, reproduced, or otherwise utilized without permission. WRF Webcast Optimizing Engineered Biofiltration (#4346) Click to refresh. No audio? Type in the box. 2012

More information

Linden Laboratory Civil, Environmental and Architectural Engineering University of Colorado, Boulder. November 9,

Linden Laboratory Civil, Environmental and Architectural Engineering University of Colorado, Boulder. November 9, Laboratory MS- 2 Coliphage Testing of the SteriPEN Adventurer Opti against the US EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers Linden Laboratory Civil, Environmental and

More information

Granular Activated Carbon System

Granular Activated Carbon System Granular Activated Carbon System Eliminating Use of Chloramines March 22, 2017 www.jacobs.com worldwide The Jacobs Team Mike McCarty, PE Project Manager Tobin Lichti, PE Water Treatment Engineer Russ Dahmer,

More information

CHLORAMINE REPLACEMENT ALTERNATIVE EVALUATION

CHLORAMINE REPLACEMENT ALTERNATIVE EVALUATION CHLORAMINE REPLACEMENT ALTERNATIVE EVALUATION DRAFT B&V PROJECT NO. 196301 B&V FILE NO. 42.2000 Black & Veatch Holding Company 2015. All rights reserved. PREPARED FOR Hannibal Board of Public Works 22

More information

Breaking a Paradigm: Benefits of Chlorine and other Oxidants on Biofiltration Pete D Adamo, PE, PhD Chance Lauderdale, PE, PhD

Breaking a Paradigm: Benefits of Chlorine and other Oxidants on Biofiltration Pete D Adamo, PE, PhD Chance Lauderdale, PE, PhD Breaking a Paradigm: Benefits of Chlorine and other Oxidants on Biofiltration Pete D Adamo, PE, PhD Chance Lauderdale, PE, PhD 2014 HDR, Inc., all rights reserved. Where we are heading 1. Background and

More information

EVALUATION OF THE IMPACT OF DISINFECTION PROCESSES ON THE FORMATION OF BIOFILMS IN POTABLE SURFACE WATER DISTRIBUTION SYSTEMS

EVALUATION OF THE IMPACT OF DISINFECTION PROCESSES ON THE FORMATION OF BIOFILMS IN POTABLE SURFACE WATER DISTRIBUTION SYSTEMS EVALUATION OF THE IMPACT OF DISINFECTION PROCESSES ON THE FORMATION OF BIOFILMS IN POTABLE SURFACE WATER DISTRIBUTION SYSTEMS INTRODUCTION Maggy N. B. Momba, T. E. Cloete, S. N. Venter and R. Kfir Potable

More information

Seasonal Source Water Quality and Treatment Challenges Town of Newburgh s Chadwick Lake Filtration Plant

Seasonal Source Water Quality and Treatment Challenges Town of Newburgh s Chadwick Lake Filtration Plant Seasonal Source Water Quality and Treatment Challenges Town of Newburgh s Chadwick Lake Filtration Plant Clayton Johnson GHD Kevin Castro GHD James Osborne Town of Newburgh Image placeholder Outline Introduction

More information

EW-90 MONTHLY OPERATIONAL REPORT DATA INSTRUCTION SHEET

EW-90 MONTHLY OPERATIONAL REPORT DATA INSTRUCTION SHEET EW-90 MONTHLY OPERATIONAL REPORT DATA INSTRUCTION SHEET 1.) The spreadsheet is protected and only provides certain areas accessible to the user. Restricted areas consist of "ppm", "flow rate," "average,"

More information

9. The specific gravity of water at 10 C (50 F) at sea level is a. 100 b. 10 c d

9. The specific gravity of water at 10 C (50 F) at sea level is a. 100 b. 10 c d GRADE 2 2 (3-POINTS EACH) 1. The distance between the water surface and the top of the filtering media in a conventional water treatment plant filter is called? a. effluent b. head loss c. submergence

More information

Cincinnati, Ohio 45268

Cincinnati, Ohio 45268 INTRODUCTION A MICROBIOLOGAL SURROGATE FOR EVALUATING TREATMENT EFFICIENCY Eugene W. Rice, Kim W. FOX, Richard J. Miltner, Darren A. Lytle and Clifford H. Johnson Drinking Water Research Division Risk

More information

Simultaneous removal of particles and dissolved organic matter in floating media filter for surface water treatment

Simultaneous removal of particles and dissolved organic matter in floating media filter for surface water treatment Desalination and Water Treatment 11 (2009) 109 114 www.deswater.com 1944-3994/1944-3986 2009 Desalination Publications. All rights reserved Simultaneous removal of particles and dissolved organic matter

More information

A Comprehensive Performance Evaluation (CPE) Approach to Addressing HABs

A Comprehensive Performance Evaluation (CPE) Approach to Addressing HABs A Comprehensive Performance Evaluation (CPE) Approach to Addressing HABs CPE Participants U.S. EPA: Alison Dugan, Tom Waters, Rich Lieberman, Craig Patterson, Val Bosscher Process Applications, Inc.: Larry

More information

DBP Treatment Strategies. Learning Objectives. DBP Control Options Optimize existing facilities

DBP Treatment Strategies. Learning Objectives. DBP Control Options Optimize existing facilities DBP Treatment Strategies Workshop developed by RCAP/AWWA and funded by the USEPA Learning Objectives Describe treatment strategies to address DBP formation Evaluate the various strategies to choose the

More information

Using Zeta Potential To Optimize Coagulation For Direct Filtration & Conventional Treatment: The Green River Filtration Facility Experience

Using Zeta Potential To Optimize Coagulation For Direct Filtration & Conventional Treatment: The Green River Filtration Facility Experience Using Zeta Potential To Optimize Coagulation For Direct Filtration & Conventional Treatment: The Green River Filtration Facility Experience May 6, 2016 Dan McCormick Gary Fox Peter Kreft AGENDA GRFF Background

More information

ACHIEVING STAGE 2 DBPR COMPLIANCE THROUGH SYSTEM OPTIMIZATION AND EFFICIENT USE OF POST-FILTRATION GAC: A 5 YEAR CASE STUDY

ACHIEVING STAGE 2 DBPR COMPLIANCE THROUGH SYSTEM OPTIMIZATION AND EFFICIENT USE OF POST-FILTRATION GAC: A 5 YEAR CASE STUDY ACHIEVING STAGE 2 DBPR COMPLIANCE THROUGH SYSTEM OPTIMIZATION AND EFFICIENT USE OF POST-FILTRATION GAC: A 5 YEAR CASE STUDY AMANDA WILLIAMS (CO-WRITER: PETER THOMPSON JR.) WATER QUALITY SUPERVISOR PALMDALE

More information

Effect of physical and chemical parameters on water treatment plant effluent quality (particle count and particle size)

Effect of physical and chemical parameters on water treatment plant effluent quality (particle count and particle size) Water Pollution IX 483 Effect of physical and chemical parameters on water treatment plant effluent quality (particle count and particle size) A. Torabian 1, A. Hesam Hasani 1 & A. R. Mehrabadi 2 1 Faculty

More information

Optimizing Filter Conditions for Improved Manganese Control During Conversion To Biofiltration [Project #4448]

Optimizing Filter Conditions for Improved Manganese Control During Conversion To Biofiltration [Project #4448] Optimizing Filter Conditions for Improved Manganese Control During Conversion To Biofiltration [Project #4448] ORDER NUMBER: 4448 DATE AVAILABLE: May 2016 PRINCIPAL INVESTIGATORS: Chance V. Lauderdale,

More information

Approaches to Filter Condition Assessment and Optimization

Approaches to Filter Condition Assessment and Optimization 2014 NC AWWA-WEA Conference Winston Salem, NC Approaches to Filter Condition Assessment and Optimization Vinod Korategere, P.E. Principal Engineer, Brown and Caldwell Barry Parsons Water Supply Division

More information

Side by Side Piloting of Process Alternatives Yields Direct Performance Comparison

Side by Side Piloting of Process Alternatives Yields Direct Performance Comparison OBG PRESENTS: OBG PRESENTS: Side by Side Piloting of Process Alternatives Yields Direct Performance Comparison LORI W. REID, P.E. New York State AWWA Spring Meeting, April 26, 2017 Outline Background Project

More information

CEE 371 Water and Wastewater Systems

CEE 371 Water and Wastewater Systems Updated: 21 November 2009 CEE 371 Water and Wastewater Systems Print version Lecture #18 Drinking Water Treatment: Granular Media Filtration Reading: Chapter 7, pp.217-225 David Reckhow CEE 371 L#18 1

More information

HSGAC: A Site Specific Granular Activated Carbon Model Design Tool

HSGAC: A Site Specific Granular Activated Carbon Model Design Tool HSGAC: A Site Specific Granular Activated Carbon Model Design Tool Mark Bishop, PE, Hazen and Sawyer Allison Reinert, EIT, Hazen and Sawyer Erik Rosenfeldt, PE, PhD, Hazen and Sawyer Ben Stanford, PhD,

More information

Enhanced Filtration. CEE 453: Laboratory Research in Environmental Engineering Spring 2001

Enhanced Filtration. CEE 453: Laboratory Research in Environmental Engineering Spring 2001 142 Introduction Slow sand filters have been used to remove particles from drinking water since the early 1800's. Although slow sand filtration is an old technology, the mechanisms responsible for particle

More information

There is no sludge treatment process at NWTP. Sludge generated from sedimentation and backwashing is drained directly to the Khan River.

There is no sludge treatment process at NWTP. Sludge generated from sedimentation and backwashing is drained directly to the Khan River. Namkhan Water Treatment Plant Luang Prabang City, Lao PDR 1. Background information Luang Prabang is a touristic city situated in northern part of Lao PDR and was declared a World Heritage City by UNESCO

More information

Coagulation Optimization: Improving the heart of the water treatment process

Coagulation Optimization: Improving the heart of the water treatment process Coagulation Optimization: Improving the heart of the water treatment process Gwyn Norman 1, Ian Douglas 1,2, Jeff Beaty 3, Josh Elliott 1,2 1 City of Ottawa Drinking Water Services 2 University of Toronto,

More information

City of Topeka Utilities Department

City of Topeka Utilities Department City of Topeka Utilities Department A Tour of Topeka s Water Treatment Facility The Topeka Water Treatment Facility uses various chemical and mechanical processes to transform raw water from the Kansas

More information

Meeting Manganese Removal Goals: A Pilot Study

Meeting Manganese Removal Goals: A Pilot Study Meeting Manganese Removal Goals: A Pilot Study Amy Gao, Russell Ford, David Best and Manthos Tsotsos PA AWWA Annual Conference Thursday, May 12, 2016 Background Oswestry WTW Owned and Operated by United

More information

Coagulation and Flocculation: Color Removal

Coagulation and Flocculation: Color Removal Coagulation and Flocculation: Color Removal Submitted to: Dr. Hashsham Research Complex Engineering Department of Civil and Environmental Engineering Michigan State University East Lansing, MI 48824 Authors

More information

Removal of Trihalomethanes by Dual Filtering Media (GAC-Sand) at El-Manshia Water Purification Plant

Removal of Trihalomethanes by Dual Filtering Media (GAC-Sand) at El-Manshia Water Purification Plant The Journal of the Egyptian Public Health Association (JEPHAss.) Vol.81 N o. 3& 4, 2006 Removal of Trihalomethanes by Dual Filtering Media (GAC-Sand) at El-Manshia Water Purification Plant Manal A. Mohamed,

More information

biologically active filtration

biologically active filtration biologically active filtration FOR TASTE AND ODOR CONTROL AT LAKE MANATEE WATER TREATMENT PLANT BY MIKE NIXON, EI, ENGINEER INTERN, MCKIM & CREED PHIL LOCKE, PE, SENIOR PROJECT MANAGER, MCKIM & CREED KATIE

More information

City of Enderby Water Treatment Plant

City of Enderby Water Treatment Plant City of Enderby Water Treatment Plant The City of Enderby is located in the beautiful NorthOkanagan with a population of 3200 residents. The central location between Vernon and Salmon Arm allows easy access

More information

ARNPRIOR WATER FILTRATION PLANT ANNUAL SUMMARY REPORT

ARNPRIOR WATER FILTRATION PLANT ANNUAL SUMMARY REPORT ARNPRIOR WATER FILTRATION PLANT ANNUAL SUMMARY REPORT 2015 Michael R. Trumble Waterworks Department Corporation of the Town of Arnprior 71 James Street Arnprior, Ontario K2E 7J5 Waterworks Number 2200009

More information

Introduction. Spokane River DO TMDL: Proposed Restrictions. Waste Load Allocation: Based on 50µg/l Total P - Seasonal (Mar Oct) for final TMDL

Introduction. Spokane River DO TMDL: Proposed Restrictions. Waste Load Allocation: Based on 50µg/l Total P - Seasonal (Mar Oct) for final TMDL City of Spokane Riverside Park Water Reclamation Facility (RPWRF) Pilot Studies for Reducing Effluent TP for Discharge to the Spokane River in preparation for the NEXT LEVEL OF TREATMENT Larry A. Esvelt

More information

Online THM Analyzer Integral to City of Benicia s Stage 2 DBPR Compliance Strategy

Online THM Analyzer Integral to City of Benicia s Stage 2 DBPR Compliance Strategy Online THM Analyzer Integral to City of Benicia s Stage 2 DBPR Compliance Strategy Author: Scott Rovanpera, Superintendent, City of Benicia Water Treatment Plant, srovanpera@ci.benicia.ca.us or Tel: +1

More information

Ready, Set, and Go: Deer Valley WTP East Basins Performance Testing, Start-Up, and Commissioning Toby Teegerstrom Brian Watson

Ready, Set, and Go: Deer Valley WTP East Basins Performance Testing, Start-Up, and Commissioning Toby Teegerstrom Brian Watson Ready, Set, and Go: Deer Valley WTP East Basins Performance Testing, Start-Up, and Commissioning Toby Teegerstrom Brian Watson January 25, 2011 Presentation Outline Background Process Overview Start-Up

More information

Result:COMPLETE Report Date: December 28 th, 2015

Result:COMPLETE Report Date: December 28 th, 2015 Send to: Clean Water Environmental, LLC 1939 Talamore Court Southeast, Grand Rapids, MI 49546 Dr. Dale Williams Result:COMPLETE Report Date: December 28 th, 2015 Customer Name: Clean Water Environmental,

More information

REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS

REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS REAL WORLD APPLICATIONS OF USING DYNAMIC SIMULATION SOFTWARE TO OPTIMIZE WATER TREATMENT PLANT PROCESS OPERATIONS (FRIT05) OCTOBER 30, 2015 Authors: Matt Ridens/CH2M, Jason Curl/CH2M Overview Drivers for

More information

A. Yavich, Ph.D., P.E. Optimization Solutions Environmental, LLC Grand Rapids, MI

A. Yavich, Ph.D., P.E. Optimization Solutions Environmental, LLC Grand Rapids, MI A. Yavich, Ph.D., P.E. Optimization Solutions Environmental, LLC Grand Rapids, MI The SMART Approach to Effective Treatment Operation Specific Management And Relationship Tools The Three Pillars Of Effective

More information

Disinfection and Disinfection Byproducts (DBP)

Disinfection and Disinfection Byproducts (DBP) Disinfection and Disinfection (DBP) 1 Regulatory Requirements for Disinfection By-Product Management & Disinfection By-Product Monitoring for Water Treatment Plants 2 DPB Rule Requirements Rule/Requirement

More information

Trident. Package Water Treatment System

Trident. Package Water Treatment System Trident Package Treatment System The Trident Package Treatment System When Microfloc products first introduced the Trident technology, it represented a significant advancement in water and wastewater treatment

More information

THE BOSSIER CITY WATER TREATMENT PLANT (Background and Current Process Layout )

THE BOSSIER CITY WATER TREATMENT PLANT (Background and Current Process Layout ) THE BOSSIER CITY WATER TREATMENT PLANT (Background and Current Process Layout - 2018) PLANT HISTORY The Bossier City Water Treatment Plant was built in 1958. The original plant had a treatment capacity

More information

Biological Consulting Services of North Florida, Inc.

Biological Consulting Services of North Florida, Inc. Biological Consulting Services of North Florida, Inc. January 5, 2016 Icon Lifesaver Ltd. Hall Chase, London Road Marks Tey, Colchester Co6 1EH, UK +44(0)1206 580999 Re: Biological filtration efficacy

More information

Biological Consulting Services of North Florida, Inc.

Biological Consulting Services of North Florida, Inc. Biological Consulting Services of North Florida, Inc. January 5, 2016 Icon Lifesaver Ltd. Hall Chase, London Road Marks Tey, Colchester Co6 1EH, UK +44(0)1206 580999 Re: Biological filtration efficacy

More information

Using Biological Treatment to Remove Metals: Norman's Pilot Test

Using Biological Treatment to Remove Metals: Norman's Pilot Test Using Biological Treatment to Remove Metals: Norman's Pilot Test Southwest AWWA Oklahoma City October 16, 2017 John Rehring, P.E. Carollo Engineers Chris Mattingly, P.E. City of Norman 2 Discussion Overview

More information

A Method to Determine Biodegradable Dissolved Organic Nitrogen in Water ND 58108, USA

A Method to Determine Biodegradable Dissolved Organic Nitrogen in Water ND 58108, USA A Method to Determine Biodegradable Dissolved Organic Nitrogen in Water Tanush Wadhawan a, Halis Simsek a, Murthy Kasi a, Kristofer Knutson b, John McEvoy c, Birgit Pruess c and Eakalak Khan a* a Department

More information

Hetch Hetchy Treatability at the Sunol Valley Water Treatment Plant

Hetch Hetchy Treatability at the Sunol Valley Water Treatment Plant Operated by the San Francisco Public Utilities Commission Hetch Hetchy Treatability at the Sunol Valley Water Treatment Plant Annual Technology Transfer Workshop November 13, 2013 Enio Sebastiani, P.E.,

More information

CITY OF HOUSTON, TEXAS: A CASE STUDY

CITY OF HOUSTON, TEXAS: A CASE STUDY CITY OF HOUSTON, TEXAS: A CASE STUDY Astro International Corporation sold Astro Model 1950s to the City of Houston prior to the sale of Astro by the current Star management. After Astro was sold to Zellweger

More information

Biological Consulting Services of North Florida, Inc.

Biological Consulting Services of North Florida, Inc. Biological Consulting Services of North Florida, Inc. June 29, 2015 Village Water Filters 1258 Rainbow Drive #2839 Silverthrone, CO 80498 RE: Biological filtration efficacy testing of the filters provided

More information

Purpose of this course. Optimization of Water Treatment Plant Operations

Purpose of this course. Optimization of Water Treatment Plant Operations Optimization of Water Treatment Plant Operations Purpose of this course Discuss cause and effect relationships between unit processes and operations Alex Yavich, Ph.D., P.E. Optimization Solutions Environmental,

More information

Taste and Odor Mitigation Strategies Laboratory-Based Analysis

Taste and Odor Mitigation Strategies Laboratory-Based Analysis Taste and Odor Mitigation Strategies Laboratory-Based Analysis 2013 PNWS-AWWA Conference Spokane, WA Kim Ervin, P.E., West Region Drinking Water Service Lead, CH2M HILL Outline Introduction - Sources of

More information

Health Based Targets Application of Log Reduction Values. Phillip Fasham Manager Water Quality Regulations and Verification

Health Based Targets Application of Log Reduction Values. Phillip Fasham Manager Water Quality Regulations and Verification Health Based Targets Application of Log Reduction Values Phillip Fasham Manager Water Quality Regulations and Verification Contents Log Credits & Treatment Barriers Typical Treatment Components and Critical

More information

LT1ESWTR Disinfection Profiling and Benchmarking

LT1ESWTR Disinfection Profiling and Benchmarking LT1ESWTR Disinfection Profiling and Benchmarking Technical Guidance Manual Log Inactivation 1.400 1.200 1.000 0.800 0.600 0.400 0.200 0.000 Log Inactivation 0 4 8 12 16 20 24 28 32 36 40 44 48 52 Week

More information

Water Treatment Plant Year-end Report for 2014

Water Treatment Plant Year-end Report for 2014 Water Treatment Plant Year-end Report for 2014 Water demand The total influent volume of water drawn from the Assiniboine River for treatment was approximately 6.03 % higher in 2014 than in 2013. 2013

More information

A Monitoring and Control Toolbox for Biological Filtration. Water Research Foundation Project 4231

A Monitoring and Control Toolbox for Biological Filtration. Water Research Foundation Project 4231 A Monitoring and Control Toolbox for Biological Filtration Water Research Foundation Project 4231 2013 Water Research Foundation. ALL RIGHTS RESERVED. 2013 Water Research Foundation. ALL RIGHTS RESERVED.

More information

Gerais, Belo Horizonte, Minas Gerais, Brazil. Topic: Utilities Asset Management Sub-topic: Water Treatment Technologies

Gerais, Belo Horizonte, Minas Gerais, Brazil. Topic: Utilities Asset Management Sub-topic: Water Treatment Technologies Assessing the coagulation effectiveness of high eutrophic water sources in batch scale Marcelo Libânio 1, Sílvia M. Gandolfi, Débora Moraes and Alaine Guerra Corresponding Author: Marcelo Libânio 1 1 Department

More information

Drinking Water Treatment Overview Filtration and Disinfection

Drinking Water Treatment Overview Filtration and Disinfection Drinking Water Treatment Overview Filtration and Disinfection April 16 th, 2009 Yousry Hamdy, M.Sc., P.Eng Nicolás s Peleato, EIT 1 Table of Contents Introduction Filtration Cartridge filters Chemical

More information

Isabelle Papineau, Ph.D., École Polytechnique de Montréal Yves Dionne (V de G) and Benoit Barbeau (EPM)

Isabelle Papineau, Ph.D., École Polytechnique de Montréal Yves Dionne (V de G) and Benoit Barbeau (EPM) Isabelle Papineau, Ph.D., École Polytechnique de Montréal Yves Dionne (V de G) and Benoit Barbeau (EPM) 16 th Canadian National Conference on Drinking Water October 28th 2014 1. Background City of Gatineau

More information

Separations Overview TDRL Seminar

Separations Overview TDRL Seminar Separations Overview TDRL Seminar Presented by: Infilco Degremont North American Footprint 5 companies 471 employees ANDERSON DUNDAS, ON 60 EMPLOYEES DEGREMONT LTD MONTREAL, QC 27 EMPLOYEES WPT SALT LAKE

More information

techcommentary Issues for Ozone for Drinking Water Treatment Introduction Ozone in Drinking Water Treatment

techcommentary Issues for Ozone for Drinking Water Treatment Introduction Ozone in Drinking Water Treatment techcommentary Issues for Ozone for Drinking Water Treatment Introduction This TechCommentary examines recent developments in ozone technology for drinking water treatment in order to answer the following

More information

Rawal Lake Water Treatment Plant Rawalpindi, Pakistan

Rawal Lake Water Treatment Plant Rawalpindi, Pakistan Rawal Lake Water Treatment Plant Rawalpindi, Pakistan 1. Background Information Rawal Lake Water Treatment Plant is managed by the Water & Sanitation Agency (WASA) under the Rawalpindi Development Authority

More information

Filter Inspection and Optimization Case Studies

Filter Inspection and Optimization Case Studies Filter Inspection and Optimization Case Studies Marvin Gnagy, P.E., President PMG Consulting, Inc. OTCO Class 3&4 Workshop August 5, 2015 Agenda Filtration inspection and maintenance basics Filter performance

More information

Quantitative Microbial Risk Estimates as a Function of Treatment Performance

Quantitative Microbial Risk Estimates as a Function of Treatment Performance Quantitative Microbial Risk Estimates as a Function of Treatment Performance Joshua Elliott, Ian P Douglas, Robert C Andrews Department of Civil Engineering, University of Toronto October 28, 2014 1 Quantitative

More information

Advancing the Design of a New 60 MGD Water Treatment Plant

Advancing the Design of a New 60 MGD Water Treatment Plant Advancing the Design of a New 60 MGD Water Treatment Plant Todd Perimon, PE Program Delivery & Real Estate Manager Willamette Water Supply Program Austin Peters, PE Water Treatment Plant Design Willamette

More information

MONTHLY OPERATION REPORT (MOR)--ALL WATER SYSTEMS

MONTHLY OPERATION REPORT (MOR)--ALL WATER SYSTEMS KENTUCKY DIVISION OF WATER DRINKING WATER BRANCH Revised //0 MONTHLY OPERATION REPORT (MOR)--ALL WATER SYSTEMS MONTH & YEAR OF: DEP Form 0--Revised 0/00 PLANT NAME: PWS NAME: PLANT CLASS: DIST. CLASS:

More information

Rectangular Basin = Volume, gal (Length, ft) x (Width, ft) x (Height, ft) x7.48 gal/cu.ft.

Rectangular Basin = Volume, gal (Length, ft) x (Width, ft) x (Height, ft) x7.48 gal/cu.ft. Units and Conversion Factors 1 cubic foot of water weighs 62.3832 lb 1 gallon of water weighs 8.34 lb 1 liter of water weighs 1,000 gm 1 mg/l = 1 part per million (ppm) 1% = 10,000 ppm ft 2 = square feet

More information

A SIMPLE METHOD OF REMOVING DISINFECTION BYPRODUCT PRECURSORS IN WATER

A SIMPLE METHOD OF REMOVING DISINFECTION BYPRODUCT PRECURSORS IN WATER A SIMPLE METHOD OF REMOVING DISINFECTION BYPRODUCT PRECURSORS IN WATER Tony Robles Town of Kirkland Lake WTP roblest@ntl.sympatico.ca Overall Responsible Operator 705-642-5626 Operator-In-Charge Abstract

More information

2014 Ontario Water Works Conference May 4-7 th, 2014 London, Ontario. Methods for evaluating pathogen log removal in a water treatment plant

2014 Ontario Water Works Conference May 4-7 th, 2014 London, Ontario. Methods for evaluating pathogen log removal in a water treatment plant 2014 Ontario Water Works Conference May 4-7 th, 2014 London, Ontario Methods for evaluating pathogen log removal in a water treatment plant Andy Campbell 1 Ian Douglas 1,2 Josh Elliott 1,2 Monica Emelko

More information