1 3.0 Statement Columbia Skylights Statement for New Construction (NC) Version 3.0 Credit Documentation The Leadership in Energy and Environmental Design () Green Building Rating System promotes the adoption of sustainable green building and development practices through the creation and implementation of universally understood and accepted tools and performance criteria. is a third-party certification program and an internationally accepted benchmark for the design, construction and operation of high performance green buildings. It provides building owners and operators the tools they need to have an immediate and measurable impact on their buildings performance. promotes a whole-building approach to sustainability by recognizing performance in six key areas of human and environmental health:. Sustainable site development 2. Water efficiency 3. Energy efficiency 4. Materials selection 5. Indoor environmental quality 6. Innovation and design Columbia Skylights may qualify your project for points in the following categories: Columbia Skylights - Potential Contribution to projects Category LEED Potential Credit Description Credit points SUSTAINABLE SITE DEVELOPMENT SSC 8.0 Light pollution reduction SSC 7.2 Heat Island Effect Roof ENERGY EFFICIENCY EAC.0 Optimze Energy Performance -9 MATERIALS SELECTION MRC 4. Must contain at least 20% recycled content -2 MRC 5.0 Materials manufactured 500-mile radius of the site -2 EQC 2.0 Increased Ventilation EQC 4.2 Low emitting materials - paints and coatings INDOOR ENVIRONMENTAL QUALITY EQC 6. Controllability of Systems Lighting EQC 6.2 Controllability of Systems Thermal Comfort EQC 8. Daylight -3 EQC 8.2 Views INNOVATION AND DESIGN IDC.0 Innovation in design -5 Table w w w.columbiask ylights.com
2 3.0 Statement How Columbia Skylights may qualify Sustainable site development Credit Credit Description Credit SS 7.2 Use roofing materials with a high Solar Reflective Index. Required SRI HEAT ISLAND EFFECT of >.78 or Vegetative coverage of > 50% or a combination of SRI and Vegetation. To calculate the SRI click here Columbia Skylights potential contribution Columbia Skylights use state of the art LoE³ technology to deliver 6 Energy Star approved glass glazing options that help to mitigate the heat island effect through high solar reflectance and high thermal emittance. See page 5 for test results on Columbia s glazing options. When used in combination with vegetated roofing Columbia Skylights and Sun tubes can assist in providing additional energy savings. points Credit SS 8.0 LIGHT POLLUTION REDUCTION Reduce the light that trespasses from a building at night. Columbia Skylight Blinds are available in three fabric options: Privacy, Light Filtering and Blackout. Privacy, Light Filtering and Blackout blinds block 20%, 35% and 99% of light respectively. Every blind comes with aluminium side rails that prevents light leakage around the edges of the fabric. All Columbia Skylight Blinds can be configured to block light leakage from a building at night. See Table 3, page 6. Energy efficiency Credit EA.0 OPTIMIZE ENERGY PERFORMANCE The most important credit as reflected in the number of points available. Achieve increasing levels of energy performance above the prerequisite standard to reduce environmental impacts associated with excessive energy use. For more information on how to gain this credit click here Columbia Skylights are a source of natural light - reducing the need for artificial light/ energy consumption. Venting Skylights are a source of natural air and ventilation. They can be used to reduce HVAC loads. Columbia s 6 glass glazing options are Energy Star approved. Each glazing option offers varying degrees of energy efficiency. See page 5 for test results. Sun Tubes used in applications where traditional windows or skylights cannot be installed lessen the need for artificial lighting solutions. Columbia s residential sun tubes are Energy Star approved in all 50 US States and in all 4 Canadian Climate zones. See Page 5 for test results. -9 Columbia Skylight Blinds can help to block up to 79% of heat gain. See Table 3 page 6. w w w.columbiask ylights.com 2
3 3.0 Statement How Columbia Skylights may qualify Materials Selection Credit Credit Description Credit MR 5.0 Materials must be manufactured within 500 miles of the project LOCALLY MANUFACTURED MATERIALS Indoor Environmental Quality Credit EQ 2.0 Increase ventilation rates to all occupied spaces by at least 30% above INCREASED VENTILATION the minimum rates in ASHRAE Provide for the effective delivery of mixing of fresh air to support safety, comfort and well-being of building occupants. Credit EQ 4. Reduce the quantity of indoor air LOW EMITTING MATERIALS: contaminants that are odorous, irritating and/or harmful to the comfort ADHESIVES AND SEALANTS and well-being of installers and occupants. Credit EQ 4.2 Reduce the quantity of indoor air LOW EMITTING MATERIALS: contaminants that are odorous, irritating and/or harmful to the comfort PAINTS AND COATINGS and well-being of installers and occupants. Credit EQ 6. Provide a high percentage of lighting CONTROLLABILITY OF SYTEMS control for the buildings occupants - LIGHTING to improve productivity and comfort. Columbia Skylights potential contribution Columbia Skylights are manufactured at 4575 Tillicum Street, Burnaby, BC, Canada. All projects within a 500 mile radius may qualify for credits. For a map of our location click here Columbia s Venting Skylights are a source of natural ventilation. Available in Manual and Electric venting kits, they providing fresh air circulation without increasing HVAC load. Venting Electric Skylight control allows for simultaneous control of multiple skylights using a wall switch or a remote. Columbia s Deluxe and Elite electric kits include rain sensors that close the skylight at the first sign of moisture. The adhesives and sealants used in Columbia s LoE³ -366 sealed glass units are emissions free and non hazardous resulting in no VOC emissions into the environment. points -2 Columbia Skylights arrive on site pre assembled, painted and coated where applicable. The finished units do not contribute to air pollution and do not release dust or fibres. Columbia Skylight Blinds provide light control for building occupants. 3 Blind options provide varying levels of light filtration. Blackout blinds block 99% of light. See Table 3 page 6. Columbia s 0 3 and 2 sun tube models can be installed with a remote dimmer kit, giving the building occupant control over the intensity of light entering a space. w w w.columbiask ylights.com 3
4 3.0 Statement How Columbia Skylights may qualify Indoor Environmental Quality Credit Credit Description Columbia Skylights potential contribution points Credit EQ 6.2 CONTROLLABILITY OF SYSTEMS THERMAL COMFORT Provide comfort controls for at least 50% of the buildings occupants. Columbia Skylights are available in fixed and venting models. Venting skylights are available in manual and electric models. Manual venting models are operated by hand or with a telescopic pole. There are 3 venting electric options: Standard, Deluxe and Elite. VE Standard kit: Capable of controlling up to 4 skylights using a single gang electrical wall switch. VE Deluxe: Capable of controlling up to 4 skylights via a remote control. The kit also includes a rain sensor that closes the skylight at the first sign of moisture. VE Elite kit: Allows control of an infinite amount of skylights via an LED Remote. The remote features a thermostat that can be programmed to open and close the skylight based on room temperature. A rain sensor is also included. Columbia Skylight Blinds offer varying levels of protection against Heat Gain based on the model selected, See table 3, page 5. Blinds can be operated by hand or by telescopic pole. Credit EQ 8. DAYLIGHT Provide building occupants with a connection between indoor and outdoor space. Achieve a minimum glazing factor of 2% in a minimum of 75% of regularly occupied areas. Columbia Skylights translucent glass and acrylic glazing offer varying degrees of soft, diffused and glare free natural light. See glazing options on page 5 for technical specifications. Columbia s residential and commercial sun tubes offer natural daylighting solutions in spaces where traditional windows or skylights cannot be installed. Columbia residential sun tubes are Energy Star certified in all 50 states and in all 4 Canadian climatic zones. See Page 5 for test results. -3 Credit EQ 8.2 VIEWS Provide access to views of the outdoors to increase occupant productivity and comfort. Columbia Skylights may qualify for points when installed in rooms with low ceilings or attics. 4
5 3.0 Statement LoE³ Clear or Neat O,2 O Venting Self Flashing Skylight Fixed Self Flashing Skylight Venting Curb Mount Skylight VCM-IF Fixed Curb Mount Skylight - Inside Fastening A VCM-OF Fixed Curb Mount Skylight - Outside Fastening B Venting Wood Deck Mount Skylight C Fixed Wood Deck Mount Skylight O,2,3,2,2 LoE³ i O LoE³ Triple Glazed Clear,2,3,2,3,2,3,2,3,2, O,2 LoE³ Bronze/Grey,2, O, LoE³ Triple Glazed Laminated O,2,2,3,2,2,2,3,2 B (Solar Heat Gain Coefficient): The fraction of incident solar radiation admitted through a window, Expressed as a number between 0 and, the lower a skylight s solar heat gain coefficient, the less solar heat it transmits. C (Visible Transmittance): The amount of visible light transmit ted. A high is desirable to maximize daylight.,2,3 Bronze A U-Factor: Indicates the rate of heat loss. The lower the U-Factor the greater a skylights resistance to heat flow. Energy Star Climate Zones Canada Energy Star Climate Zones US Columbia Sun Tube: Models,2, Columbia Skylights and Sun Tubes listed below have been rated at a 20 slope. Testing is carried out by the NFRC and is based on a specific set of environmental conditions. U-Factors are listed imperially. w w w.columbiask ylights.com 5
6 3.0 Statement Technical Specifications Design Color % Light Blocked % Heat Gain Blocked % UV Rays Blocked Privacy Pleated Smooth White 20% 40% 90% Light Filtering Cellular Frost 35% 55% 90% Blackout Cellular Egg Shell 99% 79% 90% Columbia Skylight Blinds Table 3 Skylight Testing AAMA American Architectural Manufacturers Association: AAMA 0 - Specification for windows, doors and skylights. ASTM E Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. ASTM E Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference ASTM E 33 - Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. ASTM E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference. CSA Canadian Standards Organization: CSA A440 Specification for windows, doors and skylights. NAFS North American Fenestration Standard: Specification for windows, doors and skylights. WDMA Window and Door Manufacturers Association: WDMA.S 2 - Specification for windows, doors and skylights. Columbia Skylights and Sun Tubes FIXED CURB MOUNT VENTING CURB MOUNT FIXED SELF FLASHING FIXED WOOD DECK MOUNT VENTING WOOD DECK MOUNT ROOF ACCESS HATCH VENTING SELF FLASHING RIGID SUN TUBE DISCLAIMER: The Columbia Skylights statement is a guide developed independent of the U.S. Green Building Council Certification program and the Canada Green Building Council. It does not guarantee the allocation of points for projects. Specific design and variables are the responsibility of the project design team. Columbia Manufacturing Co. Ltd Tillicum Street, Burnaby, British Columbia, Canada, V5J 3J9 Tel: Fax: Web: 6
LEED Nc 3.0 Statement
LEED Nc 3.0 Statement Version LEED Nc 3.0 Statement The U.S. Green Building Council s Leadership in Energy and Environmental Design (LEED ) New Construction 3.0 program certification is required by many
More informationPRELCO INC. INSULATING GLASS THERMALITE
LEED TECHNICAL DATA SHEET FICHE TECHNIQUE LEED PRELCO INC. About us PRELCO is a North American leader in manufacturing of high performance glazing. The product is principally used for commercial and institutional
More informationVELUX America Inc. SPECIFICATION FOR MODEL QPF SELF-FLASHED FIXED SKYLIGHT SECTION UNIT SKYLIGHTS
SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX QPF selfflashed fixed skylight. B. Unit skylight mounted directly to roof decking.
More informationPRELCO INC. PRINTED PREL-DESIGN GLASS
LEED TECHNICAL DATA SHEET FICHE TECHNIQUE LEED PRELCO INC. About us PRELCO is a North American leader in manufacturing of high performance glazing. The product is principally used for commercial and institutional
More informationSoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS
VELUX SECTION 08 62 00 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Dynamic dome unit skylight with formed curb counterflashing for mounting on site-built or prefabricated roof curbs, for flat, low-slope and
More informationEED ERTIFICATION. Kawneer Sustainable Solutions. Architectural aluminum systems Entrances + Framing Curtain walls Windows
EED ERTIFICATION Kawneer Sustainable Solutions Architectural aluminum systems Entrances + Framing Curtain walls Windows Heifer International World Headquarters Little Rock, Arkansas, USA ARCHITECT Polk
More informationTECHNICAL BULLETIN. MR 7.0 Certified Wood Encourage environmentally responsible forest management.
WDMA Window and Door Manufacturers Association 1400 E. Touhy Ave., Suite 470 Des Plaines, IL 60018-3337 Phone 847-299-5200 Fax 847-299-1286 E-mail admin@wdma.com www.wdma.com TECHNICAL BULLETIN Date Issued:
More informationENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010
ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Below is the product criteria for ENERGY STAR qualified residential windows, doors, and skylights sold in Canada
More informationSprung Instant Structures - LEED Credit Analysis CREDIT SUMMARY
CREDIT SUMMARY Introduction to LEED and Sustainable Buildings LEED (Leadership in Energy and Environmental Design) is the most widely used and recognized green building rating system. LEED is a point-based
More informationSECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS PART 1 GENERAL 1.1 SECTION INCLUDES A. Projected windows. B. Fixed windows. 1.2 RELATED SECTIONS A. Section 07900: Joint Sealers. B. Section 08400: Entrances and Storefronts.
More informationChapter 8: Indoor Environmental Quality
Chapter 8: Indoor Environmental Quality 1 Learning Objectives Minimum indoor air quality performance Environmental tobacco smoke control Enhanced indoor air quality strategies Low-emitting materials Construction
More informationASTM E1918: standard test method for measuring solar reflectance of horizontal and lowsloped surfaces in the field
IAS Accreditation Number Company Name Address TL-264 2524 E Jensen Ave. Fresno, CA 93706 Leaton Kirk, Director - Regional Operations Contact Name Telephone (559) 233-8705 Effective Date of Scope December
More informationArchitectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations
IAS Accreditation Number Company Name Address Contact Name Telephone (651) 636-3835 Effective Date of Scope August 12, 2016 Accreditation Standard ISO/IEC 17025:2005 Conformity Specifications TL-285 849
More informationENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 4.0 February 1, 2015
ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada This technical specification determines how residential windows, doors, and skylights sold in Canada qualify
More informationDecatur Fire Station No. 2
Decatur Fire Station No. 2 Decatur Fire Station No. 2 is on track to receive LEED Silver Certification from the U.S. Green Building Council. LEED certification provides independent, third-party verification
More informationResearch Analysis: Building Envelope and LEED Credits Introduction
: Building Envelope and LEED Credits Introduction Green buildings are no longer a new idea and are quickly becoming the trend in the slowly changing industry of building construction. Even though the essence
More informationENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL
ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL This technical specification determines how residential windows, doors,
More informationENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL
ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL This technical specification determines how residential windows, doors,
More informationENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL (Without Skylights)
ENERGY STAR Technical Specification for Residential Windows, Doors, and Skylights Sold in Canada Version 5.0 January 1, 2020 FINAL (Without Skylights) This technical specification determines how residential
More informationBe free to create: Polycrete, a durable choice
Be free to create: Polycrete, a durable choice Insulated Concrete Form (ICF) systems for concrete building solution have evolved over the last two decades. Our mission To conceive and promote methods and
More informationGenentech Building 20 Office LEED-CI Gold XL CONSTRUCTION
Genentech Building 20 Office LEED-CI Gold Above and Beyond A LEED Gold 50,00 s.f. tenant improvement, the space was originally designed with a goal to achieve LEED silver certification. Innovative approaches
More informationOpportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance
Opportunities for BaySystems Spray Foam & Specialty Coatings to Contribute to USGBC s LEED Performance LEED OPPORTUNITIES BaySystems products offer numerous opportunities to contribute to the performance
More informationELG4126 Sustainable Development for Electrical Engineers
ELG4126 Sustainable Development for Electrical Engineers Case Study of A Case Study on Renewable Energy and Smart Grid of Three Phases Phase Three Sustainable Development for Electrical Engineers Conduct
More informationLEED And Your Indoor Environment
LEED And Your Indoor Environment An overview of LEED v3 and Indoor Air Quality David McCauley, CIE Council Certified Indoor Environmentalist ACAC CIE #1008005 USGBC's Mission To transform the way buildings
More informationLEED-CI ANALYSIS 1 LANDMARK SQUARE STAMFORD, CT
LEED-CI ANALYSIS June 2015 1 LANDMARK SQUARE STAMFORD, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability
More informationFenestration Energy Performance:
number 9 Builder Insight Fenestration Energy Performance: A Roadmap for Understanding Requirements for Residential Buildings in British Columbia Overview Energy performance requirements for windows, doors
More informationL E E D S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N )
Project Zip Code: 92101 Project Anticipated Rating: LEED-NC Gold L E E D 2 0 0 9 S C O R E C A R D ( B U I L D I N G D E S I G N & C O N S T R U C T I O N ) 62 22 26 Project Totals A-Achieved X-Documented
More informationWindows & Deal Trays Maximum security for high-threat locations
Windows & Deal Trays Maximum security for high-threat locations Ross high security aluminum and steel windows and deal trays are certified to withstand 5 or 15 minutes of simulated mob attack and rifle-level
More informationSustainable Sites (SS): where the building is located matters. SSc1 Site Selection
The 425 Cherry Street, SE, Grand Rapids, MI location of Planned Parenthood is seeking LEED certification. The USGBC created the LEED rating systems to support the choice to build green and to provide third
More informationLEED Application Guide for Multiple Buildings and On Campus Building Projects
LEED Application Guide for Multiple Buildings and On Campus Building Projects For Use with 2009 LEED Rating Systems for Design and Construction and Operations and Maintenance Released October 31, 2011
More information08620 UNIT SKYLIGHTS Tufflite double polycarbonate glazed Frb
PART 1 GENERAL 1.1 SECTION INCLUDES A. Prefabricated Fixed Skylights. 1.2 RELATED SECTIONS A. Section 07500 - Membrane Roofing. 1.3 REFERENCES A. Aluminum Association (AA): 1. Specifications for Aluminum
More informationNBC 2015 SUBSECTION OTHER FENESTRATION ASSEMBLIES THE INTENT BEHIND THE NEW CODE PROVISIONS
NBC 2015 SUBSECTION 5.9.3 OTHER FENESTRATION ASSEMBLIES THE INTENT BEHIND THE NEW CODE PROVISIONS D.G. Kayll 1, G.R. Torok 2, and R. Jutras 3 ABSTRACT In Canada, the design, construction and installation
More informationThe skylight has a specific top and bottom and can not be rotated.
Date: 03/24/2017 Created by: Sky-GPM / WQ VSS Starting Production Code: BC 01A VS / VSE / VSS Product Data Sheet VS / VSE Starting Production Code: AX 08A The VS / VSE / VSS deck mount, top hinged, venting,
More informationAllowance Table for: General:
Allowance Table for: Adopting Credits from LEED Canada for New Construction and Major Renovations (NC) 2009 and LEED Canada for Core and Shell Development (CS) 2009 for LEED Canada-NC v1.0 (with or without
More informationLEED-CI ANALYSIS 4 LANDMARK SQUARE STAMFORD, CT
LEED-CI ANALYSIS June 2015 4 LANDMARK SQUARE STAMFORD, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationDecorative Division. GANA Decorative Glass LEED White Paper Page 1 of 23
Decorative Division White Paper on the Relevance of Decorative Glass Products to the U. S. Green Building Council Leadership in Energy and Environmental Design Green Building Rating System LEED NC Version
More informationLEED v4 Building Design and Construction Quiz #8 EQ
LEED v4 Building Design and Construction Quiz #8 EQ 1. Which of these is considered an unoccupied space? [Choose three] A. School classroom B. Mechanical room C. Meeting room D. Locker room E. Restroom
More informationDaylight and Views - daylight
LEED 2009 EQc8.1, LEEDv4 Daylight Requirements LEED 2009 (BD+C & ID+C) Through 1 of the 4 options, achieve daylighting in at least the following spaces: Regularly Occupied Spaces Points 75% 1 90% 2 Option
More informationCENTRA WINDOWS. Manufacturer for Centra Construction Group of Companies
CENTRA WINDOWS Manufacturer for Centra Construction Group of Companies Windows and Doors What to look for By Anton Van Dyk What does the Building Code Cover: Thermal Performance December, 2014 Air, Water
More informationLEED-CI ANALYSIS 6 LANDMARK SQUARE STAMFORD, CT
LEED-CI ANALYSIS June 2015 6 LANDMARK SQUARE STAMFORD, CT To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability
More informationNote year for Reference as Specified in the LEED V Manual.
PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Sustainable design Project goals. 2. Sustainable design product requirements. B. Related Sections: 1. Section 01810 - Commissioning: General commissioning
More informationVELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS
SECTION 08620 UNIT SKYLIGHTS PART 1 GENERAL 1.01 SECTION INCLUDES A. Performance and product component information for VELUX FS fixed deck mount skylight. B. VELUX Skylight Adhesive Underlayment provided
More informationSECTION ALL ULTREX DOUBLE HUNG WINDOW
SECTION 08 54 13 ALL ULTREX DOUBLE HUNG WINDOW PART 1 GENERAL 1.1 SECTION INCLUDES A. All Ultrex double hung window complete with hardware, glazing, weather strip, insect screen and half screen, grillesbetween-the
More informationSageGlass. SageGlass Product Guide. Dynamic glass for a changing world
SageGlass Dynamic glass for a changing world SageGlass Product Guide Ultra-efficient SageGlass provides unmatched performance and proven reliability in commercial, institutional and residential buildings
More informationBC Energy Efficiency Act - Regulatory Proposal for Window and Door Products
BC Energy Efficiency Act - Regulatory Proposal for Window and Door Products A number of regulations for window and door products are currently included in the Energy Efficiency Standards Regulation that
More informationAmerican Architectural Manufacturers Association VOLUME 1 - WINDOWS AND DOORS
VOLUME 1 - WINDOWS AND DOORS Window and Door Selection Guide PART 1 WINDOW SELECTION GUIDE WSG-11 PART 2 - PERFORMANCE SPECIFICATIONS Voluntary Specifications for Aluminum, Vinyl (PVC) and Wood Windows
More informationMILETTE DOORS FRENCH BIFOLD DOORS
LEED FICHE TECHNICAL TECHNIQUE DATA LEED SHEET ENTREPRISE MILETTE DOORS The Client First! Since the creation of our company in 1967, we never stopped innovating, growing and adapting ourselves to the needs
More informationHPBS [ HIGH PERFORMANCE BUILDING STANDARD]
HPBS [ HIGH PERFORMANCE BUILDING STANDARD] STATE OF MONTANA HIGH PERFORMANCE BUILDING STANDARDS MINIMUM REQUIREMENTS FOR ALL PROJECTS UNDER 17-7-201, MCA PART 2 1.1 DESIGN AND DOCUMENTATION A. Incorporate
More informationLEED LEED. Leadership in Energy and Environmental Design. A voluntary, consensus-based. high-performance, sustainable buildings and neighborhoods
LEED An Introduction to LEED V3 2009 LEED Leadership in Energy and Environmental Design A voluntary, consensus-based national standard for developing high-performance, sustainable buildings and neighborhoods
More informationLaGyp TM Gypsum Boards
LaGyp TM Gypsum Boards Red is now Green only with LaGyp TM LaGyp TM Gypsum Boards LaGyp TM Gypsum Boards are now certified by Green Building Council with 14 rating points. This makes LaGyp TM the Greenest
More informationMorning Glory Meadows 8345 North Morning Glory Road Paradise Valley, Arizona
Morning Glory Meadows 8345 North Morning Glory Road Paradise Valley, Arizona DEVELOPER/ BUILDER/ DESIGNER MRA Custom Homes, LLC Michael Abatemarco, Principal Dominick Abatemarco, Principal Chris Watts,
More informationProfessional Educational Series BSP716 USGBC # Commercial Building Science Thermal Control in Building Envelopes
Professional Educational Series BSP716 USGBC # 90006736 Commercial Building Science Thermal Control in Building Envelopes CertainTeed Building Solutions 1.5 CertainTeed is a Registered Provider with the
More informationSECTION VINYL (PVC) WINDOWS
SECTION 085313 VINYL (PVC) WINDOWS SERIES 3000/3900 NEW CONSTRUCTION DOUBLE HUNG PART 1 GENERAL 1.01 SECTION INCLUDES A. All windows of the types and sizes called for in this specification shall be furnished
More informationThe following describes those LEED categories where AAG glass-products may support the high standards defined by LEED. 2 AAG&LEED
AAG&LEED AAG, since it s founding in 2002, has been committed to environmental stewardship and demonstrated this commitment in both its responsible manufacturing processes and its energyefficient selection
More informationTHERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS
SUSTAINABLE DESIGN FORM 010.901 REV 1211 THERMA-FUSER VARIABLE AIR VOLUME DIFFUSER SYSTEMS SUSTAINABLE DESIGN GUIDE StopWaste.Org LEED-NC Platinum Energy Foundation LEED-CI Platinum Adobe East Tower LEED-EB
More informationOVERHEAD GLAZING ALUMINUM SLOPED CURTAIN WALL
ENVIRONMENTAL PRODUCT DECLARATION OVERHEAD GLAZING ALUMINUM SLOPED CURTAIN WALL Kawneer Company, Inc., part of Arconic's global Building and Construction Systems (BCS) business, has provided the commercial
More informationLEED-CI ANALYSIS 115 STEVENS AVENUE VALHALLA, NY
LEED-CI ANALYSIS June 2015 115 STEVENS AVENUE VALHALLA, NY To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability
More informationLEED-CI ANALYSIS 140 GRAND STREET WHITE PLAINS, NY
LEED-CI ANALYSIS June 2015 140 GRAND STREET WHITE PLAINS, NY To learn more please visit the sustainability section of our website: www.slgreen.com or contact Jay Black, SL Green s director of sustainability
More informationA. Product data. Unless otherwise indicated, submit the following for each type of product provided under work of this Section:
This is a guidance document with sample specification language intended to be inserted into project specifications on this subject as appropriate to the agency's environmental goals. Certain provisions,
More informationConstruction. LEED SYSTEM US Green Building Council (USGBC) Sika Egypt. Technical Department Eng/ Maram Aboelwafa
LEED SYSTEM US Green Building Council (USGBC) Technical Department Eng/ Maram Aboelwafa 2 3 Sika at Glance? Located in Baar, Switzerland, is a globally active company supplying the specialty chemicals
More informationUltimate Performance Glass
Ultimate Performance Glass CG ENGINEERING THE FUTURE OF COATED GLASS U L T I M A T E P E R F O R M A N C E G L A S S Introducing the new standard. Introducing Loå 3-366 (pronounced low E cubed-366), the
More informationContractor's Letter of Assurance
Contractor's Letter of Assurance Instructions WELL Certification is determined by onsite Performance Verification and documentation, including Letters of Assurance from the appropriate professionals overseeing
More informationContractor's Letter of Assurance
Contractor's Letter of Assurance Instructions WELL Certification and WELL Core and Shell Compliance are determined by onsite Performance Verification and Documentation, including Letters of Assurance from
More informationAERCO & LEED Sean Dabroski, LEED A.P.
AERCO & LEED Sean Dabroski, LEED A.P. The environmental impact of commercial building design, construction and operation is significant. The negative impact of buildings has become a social and economic
More informationHUNG & SLIDING WINDOWS ALUMINUM WINDOWS
ENVIRONMENTAL PRODUCT DECLARATION HUNG & SLIDING WINDOWS ALUMINUM WINDOWS Kawneer Company, Inc., part of Arconic's global Building and Construction Systems (BCS) business, has provided the commercial construction
More informationMILETTE DOORS FRENCH DOORS
CONTRIBUTION LEED FICHE TECHNICAL TECHNIQUE DATA LEED SHEET ENTREPRISE MILETTE DOORS The Client First! Since the creation of our company in 1967, we never stopped innovating, growing and adapting ourselves
More informationProdukt Declaration - LEED 2009 New Construction And Major Renovations NC & CS
Product Rating The timber product does not contain added urea-formaldehyde resins and contribute to achieve one LEED credit within IEQ Credit 4.4. The product contains 35% recycled materials and contribute
More informationVELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SKYLIGHT SECTION UNIT SKYLIGHTS
VELUX America Inc. SPECIFICATION FOR MODEL VCE/VCM/VCS VENTING CURB MOUNT SECTION 08620 - UNIT S PART 1 GENERAL 1.1 SECTION INCLUDES A. Performance and product component information for VELUX [VCM Manual
More informationNew Construction Procurement Guidelines for the Pacific Northwest
Northwest Portable Classroom Project New Construction Procurement Guidelines for the Pacific Northwest March 31, 2003 WSUCEEP03_063 Washington State University Extension Energy Program 925 Plum Street
More informationIntroduction to LEED v4 Lyle Scott May 22, 2014
Introduction to LEED v4 Lyle Scott May 22, 2014 Agenda Introduction to LEED v4 Taking a Global Approach New and More Stringent Major & Resources Introduction to LEED v4 Global Approach LEED Online Alternative
More informationSECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved
SECTION 08 87 13 WINDOW FILM Display hidden notes to specifier. (Don't know how? Click Here) Copyright 2008-2010 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Safety and Security
More informationConstruction Indoor Air Quality (IAQ) Management Plan
Denver School of Science & Technology Middle School 2000 Valentia Street Denver, CO 80238 Telephone: 303-643-5775 Main Fax: 303-673-5776 Construction Indoor Air Quality (IAQ) Management Plan Denver School
More informationNRC CONSTRUCTION TECHNOLOGY UPDATE
NRC CONSTRUCTION TECHNOLOGY UPDATE No. 82, June 2014 Performance of Tubular Daylighting Devices By A. Laouadi and H.H. Saber Tubular daylighting devices (TDDs) can economically admit natural light into
More informationCSI SECTION TUBULAR DAYLIGHTING DEVICE 21 FINISHED CEILING
CSI SECTION 08 62 23 TUBULAR DAYLIGHTING DEVICE 21 FINISHED CEILING PART 1 GENERAL NOTES TO SPECIFIER: Delete paragraph B if no accessories are required. 1.1 SECTION INCLUDES A. Tubular daylighting devices
More informationLEED 2009 Core and Shell, Commercial Project Summary and Checklist New Construction
Date of Application Path Project Project Address Owner Architect Contractor Third Party Provider LEED 2009 Core and Shell, Commercial Project Summary and Checklist New Construction Summary Permit. Provider.
More informationAcid-etched Glass for Exterior Applications A Unique Way to Move Light!
cid-etched Glass for Exterior pplications Unique Way to Move Light! University of Pennsylvania Philadelphia, P 6 mm custom pattern on position Because acid-etching is not a coating, its resistance properties
More informationEnergy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort
Please add relevant logo here Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort Presented by: Peter J. Arsenault, FAIA, NCARB, LEED-AP Disclaimer: This presentation was developed by
More informationMÉTALEC COMPANY STEEL DOOR WITH HONEYCOMB CORE
CONTRIBUTION COMPANY FICHE TECHNIQUE LEED Steel Doors and Frames has a strong expertise in commercial, industrial and institutional projects for more than 30 years. With its wide range of products, has
More informationEnvironmental Principles
Environmental Principles The Ownership group and lead consultants commitment to sustainability has been a driving force for its design. The project will achieve, per council policy for rezoning, an equivalency
More informationSECTION STRUCTURAL INSULATED PANELS
SECTION 06120 STRUCTURAL INSULATED PANELS Copyright 2011-2012 Korwall Industries, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural Insulated Roof Panels. B. Structural Insulated
More informationPROJECTED & CASEMENT WINDOWS ALUMINUM WINDOWS
ENVIRONMENTAL PRODUCT DECLARATION PROJECTED & CASEMENT WINDOWS ALUMINUM WINDOWS Kawneer Company, Inc., part of Arconic's global Building and Construction Systems (BCS) business, has provided the commercial
More informationULMA S COMPROMISE & CONTRIBUTION TO LEED CERTIFICATION
ULMA S COMPROMISE & CONTRIBUTION TO LEED CERTIFICATION UNDERSTANDING LEED Leadership in Energy and Environmental Design- LEED is an internationally recognized green building certification system, providing
More informationThe Application of LEED Green Building Rating System in Indonesia
The Application of LEED Green Building Rating System in Indonesia Baharuddin Hasanuddin University, Faculty of Engineering, Department of Architecture, Makassar-Indonesia baharsyah@yahoo.com Abstract:
More informationGreen Buildings, and LEED Certification. By Mohammad Tassi, BME, MEM, LEED AP, CxA, USGBC Faculty Sustainability & LEED Consultant
Green Buildings, and LEED Certification OUTLINE INTRODUCTION By Mohammad Tassi, BME, MEM, LEED AP, CxA, USGBC Faculty Sustainability & LEED Consultant President of Lebanese ASHRAE Chapter Senior Project
More informationCONTENTS. 71 Section 01352, #7 (Life Cycle Cost and Life Cycle Assessment) 2/1/12 Modified entire section 72 Section 01352, #8 (Sustainability
01352 Sustainable Design Requirements This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
More informationSustainable Design A DIVISION OF SHIVE-HATTERY
Sustainable Design A DIVISION OF SHIVE-HATTERY our transition to sustainability must be a deliberate choice to leave the linear surge of an extractive economy and enter a circulating, renewable one. Janine
More informationSeries B450 Guide Specification
Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com STOREFRONT SERIES B450 Shear Block Air Infiltration:
More informationSECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.
SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication
More informationPROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED
Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-05-10-03 Ontario-mNBC CODE REFERENCE: Division B / 5.10.3. DESCRIPTION OF THE
More informationLEED v4 ATAS Reference Guide
LEED v4 ATAS Reference Guide The ATAS product line can help your project qualify for points in numerous categories, including Sustainable Sites (SS), Energy and Atmosphere (EA), Indoor Environmental Quality
More informationSERIES 2100 CW-PG60-FW FIXED WINDOW
PART 1 - GENERAL 1.1 SCOPE OF WORK SERIES 2100 CW-PG60-FW FIXED WINDOW SECTION 08 51 13 ALUMINUM WINDOWS A. Furnish and install aluminum windows as shown in bid drawings and as per specifications stipulated
More informationWESTECK WINDOWS and DOORS
WESTECK WINDOWS and DOORS SECTION 08565 WOOD WINDOWS CASEMENT AWNING FIXED GENERAL Supply Wood windows as per approved Shop Drawings. PART 1 1.1 SECTION INCLUDES A. Casement Window Units. B. Awning Window
More informationLEED Saving energy with Copaco sunscreens. COPACO LEED
LEED Saving energy with sunscreens. COPACO LEED What is LEED? LEED Certification stands for Leadership in Energy and Environmental Design. It is the accepted benchmark for the design, construction, and
More informationColorado Mountain College: Sustainable Design Standards
Colorado Mountain College: Sustainable Design Standards Objective: Design and build to the highest energy and water standards in order to meet the College s Carbon Neutrality Objective in the most cost-effective
More informationAbove: Northwest corner Below: Southwest corner
Above: Northwest corner Below: Southwest corner Above: Northeast corner (Former Ice House) Below: Southeast corner (Parking garage) Above: Office main entry along Third Street Below: South courtyard showing
More informationCarboline Fireproofing Products
Carboline Fireproofing Products Credit Contributions for Leadership in Energy and Environmental Design (LEED v2009) Carboline Company 800-848-4645 1/6/2014 Background Carboline fireproofing products can
More informationSECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)
SECTION 08560 VINYL WINDOWS AND DOORS PART 1- GENERAL 1.1 SECTION INCLUDES: 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes) 2.3 Slider Windows Generations Series
More informationWhy test a system that has already been tested? Typical Manufacturers information for window to wall interface and basis for reported test results.
1 Pre-Construction Phase, & the Laboratory or Field Mock-Up Building Enclosure Commissioning: Train the Trainer Iowa State University, Ames Iowa May 10 12, 2016 Presented by Fiona Aldous Why test a system
More informationSUSTAINABILITY & LEED. Mayra Portalatin, LEED AP O + M
SUSTAINABILITY & LEED Mayra Portalatin, LEED AP O + M What s the Problem? What s the Problem? Buildings* account for 72% of total US electricity consumption and 39% of greenhouse gas emissions. U.S. Department