1 Measured Performance of Variable Speed Drives on Injection Molding Machinery Scott L. Englander, New England Power Service Company Carl H. Remley, Energy Management Consulting & Equipment Inc. To characterize the performance and savings potential of variable speed drives (VSDs) retrofit on hydraulic pumps of plastic injection molding machines, twelve installations at seven sites were monitored. The objectives of the evaluation were to estimate energy and coincident demand savings for each installation based on short-term measurements performed at the sites, and to develop a model of savings as a function of pertinent operational parameters for the purpose of estimating savings for installations not measured. It was found that the savings associated with VSD retrofits on injection molding machines varies widely, and increases with the percentage of time the machine spends in the idle step of the molding sequence. The relationship between percent savings and percent idle time developed in this study can be used in conjunction with pre- or post-retrofit power and timing measurements to reliably predict savings. Pre-retrofit power, in cases where measurements are not available, can be reliably estimated as a function of machine capacity in tons, motor size, and percent idle time using the model developed in this study. Introduction Variable speed drives (VSDs) are becoming an increasingly common retrofit on hydraulic pumps in plastic injection molding machines (IMM). In 1992 and 1993, VSDs were retrofit on 6,340 motor horsepower in injection molding applications as part of the commercial and industrial conservation programs of the New England Electric System (NEES) companies. The utility recently began to offer incentives specifically intended for VSD retrofits on IMMs. Because plastics manufacturers are common in New England, and account for 14% of the Companies industrial sector revenues, this measure is thought to have large market potential in the service territories of NEES s retail affiliates. Little is known, however, about how energy and demand savings due to retrofits of VSDs on injection molding machines are influenced by operating parameters and machine characteristics. To set appropriate financial incentive levels and eligibility criteria, accurately predict savings, and demonstrate savings to regulators and other interested parties, the utility needed to quantify the energy and demand savings due to the installation of VSDs on IMMs, based on measured results. The utility commissioned a study whose objectives were to estimate energy and coincident peak demand savings for several installations based on short-term measurements performed at the sites, and to develop a model of savings as a function of pertinent operational parameters for the purpose of predicting and estimating savings for installations not measured. In this project, a total of eight installations at four manufacturing sites in Massachusetts were studied. The sites were chosen from among those customers who had applied for incentives in Machine characteristics are listed in the complete report (EMCEI, 1993). 1 In addition to this effort, four other installations (at three sites) were monitored: three through the utility s Performance Engineering program-in which third-party contractors receive incentives to measure savings and one as part of an earlier utility pilot study. Table 1 lists the participant sites, the products they manufacture, and the machines monitored. Three of the sites are job shops they have no products of their own but manufacture for other companies. For the 12 IMMs tested at seven sites, operating hours at the sites ranged from one eight-hour shift to three, the sizes of the machines ranged from 90 tons to 700 tons, the motors controlled ranged from 20 to 60 horsepower, and the machines were made by four different manufacturers. The diversity of sites, machines, sizes, horsepower, and operating hours chosen was intended to provide a range of conditions broad enough to allow the influence of key determinants
2 Englander, Remley 2.88 of consumption and savings to be seen. Only one of the machines monitored (MBA8) had more than one motor (a 20 HP and a 50 HP). Retrofit Description For each batch of parts produced, an injection molding machine goes through a cycle which generally lasts seconds 2 and consists of six steps: mold close, injection high, injection low, screw rotate, idle or cooling, and mold open. The duration of each step of the cycle is set when a given mold is installed; plant personnel generally try to minimize the cycle time to maximize production while still achieving quality of the part produced. Under constant speed control, hydraulic control valves throttle and shunt fluid to cylinders in different parts of the machine. Although pressure and flow requirements vary drastically between different steps of the cycle, the input power to the motor under constant speed operation does not, as the pump must overcome the frictional resistance of throttled valves or bypass fluid pathways. A VSD dynamically modulates motor speed and therefore hydraulic pressure and flow-to that required to perform the task of each part of the cycle; the duration of each step remains the same as for constant speed control. Motor speed, as well as acceleration rate (or ramp time) can be finely tuned for each phase of the cycle to optimize efficiency. In addition to improving efficiency, a VSD also improves the power factor for injection molding machinery because motors designed for peak machine capacity often run at lower loads. A VSD assembly is supplied in two parts: The drive is mounted in one cabinet normally near the main IMM control panel. A second cabinet contains a small control center, where setup and control is done. Lights on the control panel tell the setup person what part of the cycle the IMM is in at any time. A digital display on the panel shows the percent of full speed at any time. All of the VSDs installed on IMMs to date under NEPSCo s programs were sold and installed by a single vendor, who also provided training. Installation of the VSD requires a licensed electrician, because motor power input must be interrupted and rerouted through the drive. Installation takes approximately four to five hours by factory-trained service people. Once the drive is installed, it must be tested; the parameters must be optimized for the IMM and the particular mold that will be run. If the savings are to be optimized, the optimization must take place each time a new mold is installed. Each of the employees who changes molds must be trained to set up and optimize the VSDs, or else savings may deteriorate. It is uncertain how widely optimization of new molds is practiced, although recent improvements in the design of the controls interface have likely facilitated this, as is discussed further below. Once a mold has been optimized, the parameters can be documented and reprogrammed the next time the mold is installed in that machine. The newer control interfaces installed with VSDs on three of the machines included in this analysis (NM4, NM5, CM10) included memory modules which store the timing and speed parameters, so that when a given mold is reinstalled, the controls can be easily and properly configured. The new interfaces also monitor power in kw and HP and log energy use, enabling operators to gauge efficiency. 3 Measurement Approach On nine of the machines tested, energy consumption and power were measured for an hour or more before and after installation; for the three machines measured under
3 Measured Performance of Variable Speed Drives the Performance Engineering program (NM4, NM5, and CM10), measurements were taken over 1.5 to 48 hours. In addition, one machine was tested with two different molds. Because cycle time varied from 22 to 54 seconds for the machines tested, at least 66 cycles were included in the measurement period. cycle can be shorter than the two second polling frequency and might therefore be excluded from short-term averages. The measurements done on the three machines monitored through the Performance Engineering program were done with a datalogger capable of accurately measuring power for distorted wave forms. For most of the measurements, a sophisticated portable power monitor was used, with the capability to measure and record to diskette RMS voltage, RMS current, true power, apparent power, reactive power, true power factor, displacement power factor, total harmonic distortion, and frequency over time. To sample voltage and current simultaneously, three voltage and three current signals are routed through a multiplexer to a 14-bit analog-to-digital converter. Each cycle is sampled at high frequency (7,680 Hz, 128 times each cycle for eight 60 Hz cycles). Digital data are passed to a 80C186 CPU and 80C187 coprocessor where the samples are processed every two seconds. From the seven groups of 1024 sampled data points, the monitor computes RMS volts, RMS amps, imbalance, power factor, and true power in watts and VA every two seconds for a three phase circuit. For eight of the machines monitored, cycle and idle time were measured using a stopwatch, and are accurate to the nearest second. For the other four, times were read off the control display. In addition to measured data, information such as operating schedules and polymer used were collected through interviews with plant personnel; motor HP and rated clamping force in tons were taken from nameplates. Results Average power for each case was calculated by dividing total consumption for the monitoring period by the duration of the period. Billing demand savings were simply the difference between pre- and post-retrofit average power; summer and winter coincident peak demand and savings were determined by multiplying average power by the fraction of time machines operated during the utility peak demand periods, 11 a.m. - 3 p.m. summer weekdays, and 5 p.m. - 7 p.m. winter weekdays. Energy consumption and savings were calculated by multiplying average power Because high frequency harmonic distortion caused by VSDs requires high frequency sampling, the monitor chosen appears to be a good choice for this type of monitoring, with one caveat: data must be accumulated over a period that far exceeds the length of a single by annual operating hours. Pre- and post-retrofit test injection molding cycle, because individual steps in the results and savings summaries are presented in Tables 2 through 4.
4 Englander, Remley 2.90
5 Measured Performance of Variable Speed Drives Absolute and relative savings varied widely across machines and molds. Absolute demand savings varied from 2.2 kw to 13.8 kw, energy savings varied from 13.2 MWh/y to 78.7 MWh/y, and relative savings varied from 4% to 61%, averaging 37%. Interestingly, power and savings normalized by motor size varied widely as well. It was thought that this variation in absolute, relative, and normalized savings could be explained by variation in other system parameters. In particular, because the greatest reduction in motor speed occurs in idle mode, it was expected that percent idle time (idle time/cycle time) would be a strong determinant of percent savings. It was also hypothesized that percent savings would depend to a lesser degree on capacity and size characteristics of the machines. Exploratory visual data analysis and stepwise regression were used to discern relationships between pre-retrofit power and savings and variables such as machine capacity, motor size, and idle time. It can be seen in Figure 1 that although percent savings are strongly related to percent idle time, there is considerable scatter and the relationship is not quite linear. It makes sense, especially for large idle times, that savings would level off in the limit, a machine idling 100% of the time would not save close to 100%. Reasoning that modeling savings as a diminishing function of idle time (e.g. logarithmic) made sense, we found through visual analysis and regression that the square root of percent idle where S f = fractional reduction in power H = motor size, HP T = rated clamping force, tons I = fractional idle time The t-ratios for all variables in the regression were significant; predicted vs. measured savings are shown in Figure 2. 4 Figure 2. Percent savings predicted by the regression model compared to measurements. Absolute reduction in power (in kw) can be reliably predicted by multiplying measured pre-retrofit power PC by the estimated percent (fractional) savings: or, if measurements of post-retrofit power P v are available instead, as follows: (2) (3) Figure 1. Percent decrease in average input power for VSDs retrofit on injection molding machines, as a function of percent idle time. time was a good determinant, and was also more symmetrically distributed than percent idle time. Remaining residuals prompted further exploration, resulting in the final model of percent savings as a function of the square root of percent idle time, motor HP, rated clamping force, and the ratio of clamping force to motor size: Annual energy savings can then be estimated by multiplying by annual operating hours. The limitation of this model alone is that absolute savings can only be predicted if average pre- or post-retrofit power is known. When attempts to relate decrease in average power (both absolute and normalized by motor HP) to other variables proved unsuccessful, a model for pre-retrofit power was sought. Figure 3 shows that pre-retrofit power is strongly but not completely determined by machine capacity. In the same manner used to derive the model for savings, pre-retrofit power (in kw) was found to be well-determined by three variables: The estimated pre-retrofit power can then be used in Equation 2 to predict absolute savings. Predicted vs.
6 Englander, Remley 2.92 measured power is shown in Figure 4. The resulting model generally makes sense physically; power under constant speed operation would be expected to increase with machine capacity, decrease with the portion of the molding cycle spent idling, and increase with motor oversizing, which may be indicated by the ratio of motor to machine capacity. Figure 3. Pre-retrofit power, for VSDS retrofit on injection molding machines, as a function of rated clamping force. (4) customers ranged between 0.8 and 2.2 years with utility incentives, and 2.0 to 5.4 without. The value of kva savings was a significant part of the total, due to improvement in power factor. Under constant speed operation, power factor ranged from during the more heavily loaded steps of the molding sequence, and dipped as low as 0.4 during the idle step. VSDs consistently lifted the power factor above 0.9 in all steps of the sequence. It is likely that power factors are low under constant speed operation because the motors are typically sized to handle the short-duration but high peak loads experienced during the injection step of the cycle. Observation of VSD set-up and operation by plant personnel revealed that in at least one facility training appeared to be insufficient, resulting in improper operation of equipment (e.g., adjustments made to hydraulic valves under VSD operation, speed settings increased arbitrarily in attempts to fix problems). Personnel at this site did not appear to have been trained to optimize VSD efficiency for each mold. Systems and procedures to facilitate rapid and accurate set-up and optimization were not in place. The vendor of the VSDs reported that additional training for personnel on all shifts at this facility resolved the problems. The vendor also reported that recent improvements in the user interface have virtually eliminated such problems, due to the greater ease-of-use, and operator feedback in the form of a digital display showing power and energy use (EICS, 1994). Conclusions Figure 4. Pre-retrofit power predicted by the regression model compared to measurements. Table 5 shows the results of a simple economic analysis intended to demonstrate the cost-effectiveness of the installations from the customer s perspective. The effective kva rate is used as the basis for billing demand savings because all customers are billed on this basis (facility power factor is less than 0.9). Simple payback to The energy and coincident demand savings associated with VSD retrofits on injection molding machines vary widely. Savings increases with the percentage of the molding cycle spent idling and depends to a lesser extent on motor size and rated clamping force. This is reasonable because under constant speed operation, it is in the idle phase of the cycle that the hydraulic valves must throttle the flow of the oil the most. The model for percent savings developed in this study can be used in conjunction with pre- or post-retrofit power and timing measurements to reliably predict savings. Pre-retrofit power, in cases where measurements are not available, can be reliably estimated as a function of machine capacity in tons, motor size, and percent idle time using the model developed in this study. Although other variables such as machine make, age, and polymer used may also influence consumption and savings, not enough data were obtained in this study to draw any conclusions. The models developed here must be used with the caveats that the sample on which they are based is small relative to the number of parameters used, the distributions of values for some of the parameters (notably T/H) are less
7 Measured Performance of Variable Speed Drives than symmetrical, and the few data points at the edges of the range of machine capacity limit the models applicability in these regions. Although most installations would be expected to operate in the range of most of our measurements, further measurement is required to extend the range of the savings and power models. Because only one machine in the sample used more than one motor, the quantitative results presented here should also not be applied indiscriminately to machines with multiple motors. Because most IMMs are likely to be operated with idle times less than 60% of cycle times, and the majority of machines in use are no larger than 500 tons and have a single motor, the models developed in this study are expected to be widely applicable. Further research is needed to develop a theoretical underpinning for the models. A substantial portion of savings could explained by percent idle time alone. Although horsepower, capacity, and the ratio of the two turned out to be good additional predictors, it is not exactly clear why. The model for constant speed power is more intuitive, but could also benefit from further study. Detailed cycle-level measurements could go a long way toward answering such questions. The VSDs were observed to consistently increase power factor. Because industrial customers often pay a penalty for low power factor, the benefits of increasing power factor can be significant. It should be noted, however, that the VSDs increased power factor because of the dynamic and spiky loading pattern of the application and the commensurate oversizing of the motors; VSDs have been observed to decrease power factor in other applications where the motor under constant speed operation experiences loads close to capacity for much of the time. The anecdotal observations of set-up and operating procedure emphasize the importance of commissioning and operator interface design to achieving and maintaining savings. Plant personnel accustomed to adjusting hydraulic valves as a means of tuning machine operation may continue to do so (at the expense of savings) unless they are comfortable with adjusting VSD settings, and find it easier to do so. Unless plant personnel buy in to the new systems, savings may be lost once new molds are used. Acceptance by operators may be facilitated by training them how to optimize performance for each mold (and requirements by management to do so), and a user-friendly control interface which includes feedback on efficiency. Once optimum operating parameters are established, simple systems such as a card attached to the mold listing VSD settings can help ensure persistence of savings. New technologies such as memory modules which can store VSD settings for each mold can facilitate rapid and proper set-up and thereby enhance persistence of savings. Finally, future repeat measurements of the IMMs used in this study would be useful in the assessment of persistence.
8 Englander r Remley 2.94 Acknowledgments Margaret Campbell of New England Power Service Company commissioned the pilot study resulting in the measurements of MBA8 presented here; the measurements were performed by Matt Russell of Power Conversion Systems. John Abraham of EES did the Performance Engineering measurements and savings estimates on three machines. All the VSDs were installed by Efficient Industrial Control Systems of Avon, Connecticut. Endnotes 1. The additional data, results, and models presented here extend the simpler analysis documented in the complete report of the study (EMCEI, 1993). 3. Efficient Industrial Control Systems, Inc., Personal communication, Roger Fritz. 4. It should be noted that the distribution of values of T/H was asymmetric, unlike those of the other variables, opening to question the validity of including the variable. Reference Energy Management Consulting and Equipment, Inc., Measured Performance of Variable Speed Drives on Injection Molding Hydraulic Pumps, Final Report, Report to New England Power Service Company, revised September The authors have come across machines operating with cycle times as long as 150 seconds, although this is uncommon.
Project Measurement and Verification Procedures
Project and Verification Procedures 1) Introduction The objective of measurement and verification (M&V) activities at the Project level is to confirm that the Measures that are supported by the Retrofit
More informationFinal Report for National Grid USA Service Company. Evaluation of 2003 Custom Process Installations Part I. August 24, 2005.
Final Report for National Grid USA Service Company Evaluation of 2003 Custom Process Installations Part I August 24, 2005 Submitted by Select Energy Services, Inc. is the energy services subsidiary of
More informationXylem VSD Payback Tool
Xylem VSD Payback Tool Significant opportunities exist to reduce pumping system energy consumption through smart hydraulic system design, retrofitting to variable speed performance and operating practices.
More informationModeling and Simulation of Air Compressor Energy Use
Modeling and Simulation of Air Compressor Energy Use Chris Schmidt, Energy & Resource Solutions, Inc. Kelly Kissock, Department of Mechanical Engineering, University of Dayton ABSTRACT This paper describes
More informationPermanent Load Shifting Program
1. Program Description Permanent Load Shifting (PLS) can help reduce system peak load by storing energy produced during off-peak period and shifting electricity use from on-peak to off-peak periods on
More informationNew Approaches in Automating and Optimizing Demand Response to Solve Peak Load Management Problems
New Approaches in Automating and Optimizing Demand Response to Solve Peak Load Management Problems WHITE PAPER Abstract Grid power demand peaks and increasing supply/ demand inbalances create management
More informationExperts speak on UPS output Watt, VA, and Power Factor ratings.
Experts speak on UPS output Watt, VA, and Power Factor ratings. White Paper #13 Executive Summary Experts speak on the subject of UPS output ratings, and how the use of UPS with an output power factor
More informationESTIMATING ENERGY SAVINGS IN COMPRESSED AIR SYSTEMS
ESTIMATING ENERGY SAVINGS IN COMPRESSED AIR SYSTEMS Chris Schmidt Project Engineer Energy and Resource Solutions Haverhill, Massachusetts Kelly Kissock, Ph.D., P.E. Associate Professor / Director Industrial
More informationEconPlast. Spritzgiessautomaten
Spritzgiessautomaten The proper response to rising electricity prices is energy efficiency Annegret-Cl. Agricola / Department Head of the German Energy Agency It requires considerable amounts of energy
More informationSection 2: Estimating Energy Savings
Section 2: Estimating Energy Savings 2.1 Estimating Methods... 2-2 2.2 Estimation Software... 2-2 2.2.1 Comprehensive Lighting... 2-3 2.2.2 Lighting Controls... 2-3 2.2.3 High-Efficiency Packaged A/C or
More informationM&V Fundamentals & the International Performance Measurement and Verification Protocol
M&V Fundamentals & the International Performance Measurement and Verification Protocol What is M&V? Measurement & Verification (M&V) is the process of using measurements to reliably determine actual saving
More informationUtilities Used in Production 129
www.revenue.state.mn.us Utilities Used in Production 129 Sales Tax Fact Sheet 129 Fact Sheet What s New in 2017 We added information on different methods to calculate exempt utility percentages. Utility
More informationGE Digital Executive Brief. Enhance your ability to produce the right goods in time to satisfy customer demand
Enhance your ability to produce the right goods in time to satisfy customer demand Traditionally, successful production has relied heavily on skilled personnel. Experienced employees installed equipment
More informationCost Savings and Efficiency through Power Quality Monitoring. National Instruments
Cost Savings and Efficiency through Power Quality Monitoring National Instruments Measure It. Fix It. Once you start monitoring something you know you can fix things -Dave Brandt Electrical Engineer NUCOR
More informationGRUNDFOS CRE range. Customised pump solutions Optimised for temperature control
GRUNDFOS CRE range Customised pump solutions Optimised for temperature control Get upgraded. Twice. A double upgrade for temperature control applications Your first upgrade: The new CRE with three-phase
More informationAR No. # Efficient Irrigation
AR No. # Efficient Irrigation Recommendation Optimize the facilities irrigation pumping system by ensuring pumps are operating at their Best Efficiency Point (BEP). We estimate the system pumping efficiency
More informationEco-Flow - C VARIABLE FREQUENCY DRIVE PRODUCT BROCHURE. for Commercial Swimming Pools & Water Feature Pumps. H flow 2. Pool & Spa Products Division
H flow 2 Pool & Spa Products Division Eco-Flow - C VARIABLE FREQUENCY DRIVE for Commercial Swimming Pools & Water Feature Pumps PRODUCT BROCHURE Tel: 888 635 0296 www.h2flow.net We don t make Pool Pumps,
More information1. Explain how design simplification can be applied to the manufacturing process.
Chapter 3 Operation Analysis Questions 1. Explain how design simplification can be applied to the manufacturing process. Simplicity in product design invariably results in better production. A complex
More informationLarge Scale Governor System Retrofits U.S. Army Corps of Engineers, North Pacific Region
Large Scale Governor System Retrofits U.S. Army Corps of Engineers, North Pacific Region Deepak Aswani 1, American Governor Company, Warminster, PA Gary Rosenberger 2, American Governor Company, Warminster,
More informationOVERALL EFFICIENCY CONSIDERATION OF PNEUMATIC SYSTEMS INCLUDING COMPRESSOR, DRYER, PIPE AND ACTUATOR
OVERALL EFFICIENCY CONSIDERATION OF PNEUMATIC SYSTEMS INCLUDING COMPRESSOR, DRYER, PIPE AND ACTUATOR Toshiharu KAGAWA*, Maolin CAI*, Hirotaka KAMEYA** *P recision and Intelligence Laboratory, Tokyo Institute
More informationPersistence Tracking in a Retro-commissioning Program
Persistence Tracking in a Retro-commissioning Program Mike Eardley Architectural Energy Corporation Synopsis The persistence of energy savings and electrical demand reductions created by retrocommissioning
More informationHydraulic power units energy-efficient, silent, reliable
Hydraulic power units energy-eicient, silent, reliable 2 System partner System partner for tailored power units Energy-eicient, silent, and reliable: You specify the boundary conditions for your task,
More informationARE YOUR VARIABLE SPEED PUMPING APPLICATIONS DELIVERING THE PREDICTED SAVINGS? IMPROVING CONTROL TO MAXIMIZE RESULTS
ARE YOUR VARIABLE SPEED PUMPING APPLICATIONS DELIVERING THE PREDICTED SAVINGS? IMPROVING CONTROL TO MAXIMIZE RESULTS University of Dayton, Dayton, Ohio Vijay Gopalakrishnan, Lead Engineer Alexandra Brogan,
More informationCustom Application 2018 Retrofit Program
The Retrofit Program is designed for Commercial and Industrial (C&I) customers to help replace aging and inefficient equipment and systems with more energy efficient technologies. Tailored to a customer's
More informationPumping System Vibration
Pumping System Vibration Understanding the Fundamentals Eric J. Olson Mechanical Solutions, Inc. (MSI) ejo@mechsol.com Agenda 1. Vibration testing and analysis fundamentals 2. Structural and acoustic resonance
More informationApplication of Variable Frequency Drives for Energy Savings
Application of Variable Frequency Drives for Energy Savings Scott McGlamery,.E. Department of Electrical Engineering, Hixson, Cincinnati, OH Abstract- While almost any facility could potentially benefit
More informationEXPERIMENTAL INVESTIGATION OF THE PERFORMANCE OF A RΕVERSE OSMOSIS DESALINATION UNIT OPERATING UNDER FULL AND PART LOAD CONDITIONS
EXPERIMENTAL INVESTIGATION OF THE PERFORMANCE OF A RΕVERSE OSMOSIS DESALINATION UNIT OPERATING UNDER FULL AND PART LOAD CONDITIONS E. Dimitriou*, E. Sh. Mohamed, G. Kyriakarakos, G. Papadakis Department
More informationEnergy Savers: Air-Source Heat Pumps
1 of 5 4/25/2009 8:55 AM U.S. Department of Energy - Energy Efficiency and Renewable Energy Energy Savers Air-Source Heat Pumps An air-source heat pump can provide efficient heating and cooling for your
More informationw. Craig Racine, Alternative Energy Systems Consulting, Inc.
QUANTIFICATION OF ELECTRICITY SAVINGS FOR INDUSTRIAL APPLICATIONS THROUGH ON-SITE VERIFICATION AND METERING Mark S. Martinez, Southern California Edison Company w. Craig Racine, Alternative Energy Systems
More informationSGM Engineering, Inc.
SGM Engineering, Inc. 1. What is a typical Central Energy Plant consists of? BAS controls, chillers, pumps, cooling towers, electrical distribution, piping, chemicals, heating systems, and generators.
More informationDevelopment of Advanced Structural Foam Injection Molding. Kye Kim. A thesis submitted in partial fulfillment of the requirements for the degree of
Development of Advanced Structural Foam Injection Molding Kye Kim A thesis submitted in partial fulfillment of the requirements for the degree of BACHELOR OF APPLIED SCIENCE Supervisor: Park, C.B. Department
More informationIndustrial Customer Case Studies in an Era of Smart Manufacturing
Industrial Customer Case Studies in an Era of Smart Manufacturing ABSTRACT Sandy Glatt, U.S. Department of Energy Amelie Goldberg, Institute for Industrial Productivity Robert P. Taylor, Institute for
More informationDecoupling vs. Lost Revenues. Regulatory Considerations
Decoupling vs. Lost Revenues Regulatory Considerations David Moskovitz Cheryl Harrington Tom Austin May 1992 Regulatory Assistance Project 177 Water Street Gardiner, Maine 04345 207-582-1135 DECOUPLING
More informationNEW JERSEY BOARD OF PUBLIC UTILITIES N.J.A.C. 14:4-9 Net Metering and Interconnection Standards for Class I Renewable Energy Systems
NEW JERSEY BOARD OF PUBLIC UTILITIES N.J.A.C. 14:4-9 Net Metering and Interconnection Standards for Class I Renewable Energy Systems SUBCHAPTER 9 NET METERING AND INTERCONNECTION STANDARDS FOR CLASS I
More informationThe Latest Generation of VFDs
The Latest Generation of VFDs Written by: Thomas R. Neuberger, Eaton Corporation Reduce maintenance, improve efficiency and solve key pump application challenges with variable frequency drive technology.
More informationEnergy Efficiency Impact Study
Energy Efficiency Impact Study for the Preferred Resources Pilot February, 2016 For further information, contact PreferredResources@sce.com 2 1. Executive Summary Southern California Edison (SCE) is interested
More informationGround source heat pump system (vp) Design Envelope application guide
Ground source heat pump system (vp) Design Envelope File No: 9.564 Date: november 14, 2014 Supersedes: 9.564 Date: september 19, 2014 design envelope s performance improvements are among the top priorities
More informationSIZING OPTIMIZATION OF A CENTRAL CHILLED WATER SYSTEM
SIZING OPTIMIZATION OF A CENTRAL CHILLED WATER SYSTEM by Jon B. Belcher, PE INTRODUCTION Your organization has decided to build a central chilled water plant to supply comfort cooling to several existing
More informationFAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.
FAST POWER FACTOR REGULATOR Computer-14df - xx - 144a INSTRUCTION MANUAL ( M 981 611 / 00A ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14f --------- Page 2 POWER FACTOR REGULATOR COMPUTER-
More informationThe Idaho Power Company
Preventing Electrical Pollution Working with Customers to Control Electrical Pollution Idaho Power s Approach By Jon D Roholt For the IEEE PES T&D Conference & Exposition Chicago IL, April 23, 2008 The
More informationOptimao. In control since Improving the production process through better web tension control
Optimao In control since 1995 Improving the production process through better web tension control The significance of web tension control Web tension effect achieved when opposing longitudinal forces are
More informationCIP Energy Profiles. Rich Morgan Product Application Engineer Rockwell Automation. Rick Blair System Architect Schneider Electric
CIP Energy Profiles Rich Morgan Product Application Engineer Rockwell Automation Rick Blair System Architect Schneider Electric Presented at the ODVA 2014 Industry Conference & 16 th Annual Meeting March
More informationGround-Coupled Heat Pump And Energy Storage
Ground-Coupled Heat Pump And Energy Storage By Ed Lohrenz, Member ASHRAE; and Sergio Almeida, P.Eng., Member ASHRAE Ground-coupled heat pump (GCHP) systems consume less purchased energy than an HVAC system
More informationFluke Oscilloscope Calibration Solutions. Helping you measure up to the highest standards
Fluke Oscilloscope Calibration Solutions Helping you measure up to the highest standards Fluke offers more ways to meet your oscilloscope calibration needs If your organization is like most, you are competing
More informationInnotech is a registered Trademark of Mass Electronics Pty Ltd Copyright 2013 Mass Electronics Pty Ltd
CHILLED WATER PRIMARY SECONDARY & THERMAL ENERGY STORAGE DIGITAL CONTROL SYSTEM FUNDAMENTALS Presented by : Ben Macdonald QLD Sales Manager Innotech Control Systems Australia www.innotech.com.au Innotech
More informationFixed Demand (Block Demand) The utility company sends a signal to synchronize the start of the Maximum Demand period.
Maximum demand control systems M 6 M.6.02 GB Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kw h) Reactive energy consumption
More informationTaking the LED Pick and Place Challenge
Taking the LED Pick and Place Challenge Joshua J. Markle Cree, Inc. Joshua_markle@cree.com Abstract For the past few years there has been a shift in the Lighting Industry that has carried over to the surface
More informationEnergy Savings Made Simple
Energy Savings Made Simple SWARM LOGIC FOR DEMAND MANAGEMENT EXCESSIVE COINCIDENCE LEADS TO HIGHER THAN NECESSARY PEAK DEMAND The issue at hand is a lack of system-wide coordination of HVAC loads, which
More informationLow Energy Consumption, High-Speed Productivity LCG 3015 AJ. Fiber Laser Cutting System
Low Energy Consumption, High-Speed Productivity LCG 3015 AJ Fiber Laser Cutting System Development Concept The LCG 3015 AJ is the latest addition to Amada's line of fiber laser cutting systems. The 2kW
More informationMeasuring Energy Savings at Verallia
0 1 0 2 / 1 2 SUSTAINABLE MANUFACTURING FEATURES BY ROD SMITH, COMPRESSED AIR BEST PRACTICES MAGAZINE Compressed Air Best Practices interviewed Gregory Rhames, Asset Reliability Manager/Energy Manager
More informationIntelligent Well Management System
Intelligent Well Management System By combining our vast years of experience in the Oil/Gas market with the versatility of the Schneider Electric Altivar 930 variable frequency drive (VFD), the Well iknow
More informationBioreactors Prof G. K. Suraishkumar Department of Biotechnology Indian Institute of Technology, Madras. Lecture - 02 Sterilization
Bioreactors Prof G. K. Suraishkumar Department of Biotechnology Indian Institute of Technology, Madras Lecture - 02 Sterilization Welcome, to this second lecture on Bioreactors. This is a mooc on Bioreactors.
More informationRESEARCH NOTE IMPROVING ANALYTICS DEPLOYMENTS WITH IBM PARTNERS
Document L127 RESEARCH NOTE IMPROVING ANALYTICS DEPLOYMENTS WITH IBM PARTNERS THE BOTTOM LINE In analyzing deployments of IBM Business Analytics Software, Nucleus has found that midsize organizations adopting
More informationSENDING THE RIGHT SIGNALS WITH QM. Presented by Polk State College
SENDING THE RIGHT SIGNALS WITH QM Presented by Polk State College POLK STATE COLLEGE Located in Central Florida Serving approximately 16,000 students annually via F2F, Hybrid and Online Two Main Campuses
More informationAnalysis of the air conditioning systems in a blown films manufacturing plant in the southeastern United States
Analysis of the air conditioning systems in a blown films manufacturing plant in the southeastern United States Dr. George Ford 1, Dr. William McDaniel 2 and Mr. Paul Yanik 3 ABSTRACT This paper is a study
More informationGlobal Partners in Plastics
THE K-TEC SERIES400 to 4,500 kn Global Partners in Plastics K-TEC High Performance Injection Molding Machines Exceptional precision and repeatability, fast cycle times, high injection rates and pressure,
More informationRESTORE 1030TM Testing Protocol
RESTORE 1030TM Testing Protocol Test protocols will vary depending on the type of equipment being evaluated. The length of time required to do the testing, however, remains consistent no matter what the
More informationSystec Servo highly versatile
Systec Servo highly versatile Trust in technology Performance, productivity and environmental protection are the cornerstones of Sumitomo (SHI) Demag s product solutions. As our customer, you benefit from
More informationLesson 7: Watt s in a Name(plate)?
Lesson 7: Watt s in a Name(plate)? Overview In this lesson, students determine how much electricity a particular device uses by reading electric nameplates and using Kill A Watt meters that monitor electrical
More informationMaking Large UPS Systems More Efficient
Making Large UPS Systems More Efficient By Victor Avelar White Paper #108 Executive Summary As energy resources become more scarce and more expensive, electrical efficiency is becoming a more important
More informationThermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability
Thermoforming packaging machine R 145 with MULTIVAC Clean Design Maximum process reliability and cleanroom suitability MULTIVAC R 145 Clean Design Thermoforming packaging machine R 145 with MULTIVAC Clean
More informationThe intuitive control of the future MC6 Multitouch
The intuitive control of the future Engineering Passion 2 Facts and figures Facts and figures regarding the control Most important features at a glance "Tactile" control of the axes with SlideX technology
More informationDEVELOPMENT AND USE OF SIMULATION TRAINERS FOR PIPELINE CONTROLLERS. D.M. Scott Enbridge Pipe Line Company Edmonton, Alberta, Canada
IPC2000-254 DEVELOPMENT AND USE OF SIMULATION TRAINERS FOR PIPELINE CONTROLLERS D.M. Scott Enbridge Pipe Line Company Edmonton, Alberta, Canada ABSTRACT Enbridge is in the forefront of development and
More informationTechnological Training Programs
Technological Training Programs On behalf of Noaman Engineering, I would like to introduce you to our training courses. All of our courses cover Theoretical, Practical, and software implementation and
More informationOn the way to Industrie 4.0 Driving the Digital Enterprise Siemens AG 2015 siemens.de/sps15
Press Webcast SPS IPC Drives 2015 October 8, 2015 Heinz Eisenbeiss On the way to Industrie 4.0 Driving the Digital Enterprise siemens.de/sps15 Press Webcast SPS IPC Drives 2015 October 8, 2015 Heinz Eisenbeiss
More informationAerospace Manufacturing. Productivity and performance, from machining to final assembly
Aerospace Manufacturing Productivity and performance, from machining to final assembly 2 Aerospace Manufacturing Capabilities Meeting the needs of the aerospace market with solutions and products that
More informationConsiderations for Planning and Scheduling. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN
Considerations for Planning and Scheduling Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Introduction Planning and scheduling tasks tend to be based upon fixed times in both the internal and
More informationCRM Buyers Guide. CompareBusinessProducts. CRM Buyers Guide
CompareBusinessProducts CRM Buyers Guide If you have any questions, please call 877-852-5226 where one of our analysts will be happy to help you understand your options and find a good solution. CRM Buyers
More informationEnergy Management Services. Air Demand Analysis. kaeser.com
Energy Management Services Air Demand Analysis kaeser.com Compressed Air Assessments Improving system performance In the course of helping thousands of customers save millions of dollars through compressed
More informationChapter 07 Design of Work Systems
Chapter 07 Design of Work Systems True / False Questions 1. Ergonomics is the use of computers and robots in the workplace. TLO: 2 2. Specialization is one of the sources of disagreement between the efficiency
More informationUnderground Conveyor Systems Product Overview
Underground Conveyor Systems Product Overview Underground Conveyor Systems Joy conveyor equipment is utilised in some of the most productive material handling applications worldwide. Our equipment is designed
More informationCX series injection molding machines
SUSTAINED HIGH PERFORMANCE CX series injection molding machines IN PARTNERSHIP WITH INDUSTRY KraussMaffei is a premium partner for the plastics and rubber processing industries worldwide Automotive White
More informationThe new PumpDrive: flexible speed control for top efficiency
Our technology. Your success. Pumps n Valves n Service The new PumpDrive: flexible speed control for top efficiency 02 Introduction Optimum operating speeds Maximum savings Demand-driven operation allows
More informationThe Concept of Motor System Maintenance and Management. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Reliability Services
The Concept of Motor System Maintenance and Management Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN Reliability Services Introduction A variety of concepts related to the term motor management
More informationFundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX
Fundamental Overview of an NGL Meter Station Design Tony Lockard Enterprise Products 1100 Louisiana Street, Houston, TX 77002-5227 Overview In this paper I will attempt to give a fundamental overview of
More informationUnited Illuminating Company and Connecticut Light & Power. Final Report, 2005 Coincidence Factor Study
United Illuminating Company and Connecticut Light & Power, 2005 Coincidence Factor Study Prepared for: The Connecticut Energy Conservation Management Board and United Illuminating 157 Church Street New
More informationModal Analysis as a Tool to Resolve Pump Vibration Issues
Modal Analysis as a Tool to Resolve Pump Vibration Issues John Koch HDR, Bellevue, WA jkoch@hdrinc.com ABSTRACT Vibration spectrum analysis and modal analysis are tools designers and plant staff can use
More informationPredictive Analytics for Pumps, Valves and Seals Experience In Motion
Intelligent Performance Solutions Predictive Analytics for Pumps, Valves and Seals Experience In Motion Driving step change in reliability The Flowserve IPS suite of products, software and services helps
More informationSCIENTIFIC MANAGEMENT TECHNIQUES, INC.
SCIENTIFIC MANAGEMENT TECHNIQUES, INC. Unique Testing and Training Solutions for Industry Solving the Skills Crisis by Helping Manufacturers Identify, Train, and Keep the Best People Forty Six Years of
More informationReport to the Texas Senate Committee on Business & Commerce
Report to the Texas Senate Committee on Business & Commerce Beth Garza Director, ERCOT IMM bgarza@potomaceconomics.com 512-225-7077 Potomac Economics Independent Market Monitor for ERCOT May 1, 2018 Introduction
More informationVirtual Planner. 2020spaces.com/2020VirtualPlanner
Virtual Planner 2020 Virtual Planner is an easy-to-use, 3D space planning application that turns the daunting task of remodeling an interior space into an easy, even exciting one. A powerful sales and
More informationUFL Micro Biogas CHPs
UFL Micro Biogas CHPs The UFL Micro Biogas CHPs are based on the highly durable Petter industrial diesel engine. Low cost replacement parts are available worldwide. This range of micro biogas CHPs has
More informationStudy on Valve Management of DEH for Steam Turbine *
Energy and Power Engineering, 03, 5, 39-33 doi:0.436/epe.03.54b063 Published Online July 03 (http://www.scirp.org/journal/epe) Study on Valve Management of DEH for Steam Turbine * Changjie Yin, Jizhen
More informationSaving Energy on Electric, Lighting and Water Systems
Sponsored by Nexus Greenhouse Systems Saving Energy on Electric, Lighting and Water Systems Terms & Conditions of Use Proper installation and maintenance of all electronic systems can lead to significant
More informationSmall Oil-Less Centrifugal Compressors: Bringing Energy Efficiency and Reduced Costs to Chiller Plants
Small Oil-Less Centrifugal Compressors: Bringing Energy Efficiency and Reduced Costs to Chiller Plants Ben Erpelding and Annika Moman, San Diego Regional Energy Office ABSTRACT According the U.S. Department
More informationCommercial & Industrial Large Water Meters
Commercial & Industrial Large Water Meters 1 Water Distribution System 2 Large Meter Family 3 Large Meter Family 4 Specifications Clean Water Applications Maximum Operating Temperature: 80 deg F Maximum
More informationEstablishing Best Practice Compressed Air Flows
Establishing Best Practice Compressed Air Flows Sponsored by Featured Speaker: Hank van Ormer, Air Power USA For your free subscription, please visit http://www.airbestpractices.com/magazine/subscription.
More informationHigh Speed Data Collection with FactoryTalk Historian ME
High Speed Data Collection with FactoryTalk Historian ME Presented by Enbridge Pipeline Rockwell Automation 2 What is a PI Server? How big?? What if it is small enough to fit in your hand? 3 Agenda Introduction
More informationIn cooperation with. Collection, analysis, and documentation of process data DataXplorer. Engineering Passion
In cooperation with Collection, analysis, and documentation of process data Engineering Passion Collection, analysis, and documentation of process data Insight into all processes All signals of the injection
More informationVerification of Chiller Performance Promotion and Energy Saving
Engineering, 2013, 5, 141-145 http://dx.doi.org/10.4236/eng.2013.51a020 Published Online January 2013 (http://www.scirp.org/journal/eng) Verification of Chiller Performance Promotion and Energy Saving
More informationElmwood Golf Course Solar PV Initial Feasibility Study
Elmwood Golf Course Solar PV Prepared by: SAC Consulting Contact: Email: Fiona Salter fiona.salter@sac.co.uk Phone: 0131 603 7513 Date: 27 th August 2015 1 Contents 1 Contents... 1 2 Introduction... 1
More informationBy: Adrian Chu, Department of Industrial & Systems Engineering, University of Washington, Seattle, Washington November 12, 2009.
OPT Report By: Adrian Chu, Department of Industrial & Systems Engineering, University of Washington, Seattle, Washington 98195. November 12, 2009. The Goal Every manufacturing company has one goal to make
More informationOptimal network topology and reliability indices to be used in the design of power distribution networks in oil and gas plants *
Optimal network topology and reliability indices to be used in the design of power distribution networks in oil and gas plants * R Naidoo and EJ Manning University of Pretoria, Pretoria, South Africa ABSTRACT:
More informationDISCUSSION ON UNDERPINNING (28/3/12)
DISCUSSION ON UNDERPINNING (28/3/12) The following are opinions of the writer related to various forms of underpinning and foundation stabilization. It should be noted that every situation requires an
More informationFarm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station
Farm Energy IQ Farms Today Securing Our Energy Future Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station Farm Energy IQ Farm Energy Efficiency Principles Tom Manning,
More informationElectric Rate Schedule GS-TOU General Service Commercial, Time-of-Use
Page 1 of 5 Applicability This Schedule is offered as an option to commercial customers having demands from 500 kilowatts up to 1,000 kilowatts in any month during the previous twelve (12) months. Character
More informationChapter 9 THE EFFECT OF THERMAL TRANSFORMATIONS ON THE MELT MASS-FLOW RATE AND THE MELT VOLUME-FLOW RATE OF ABS Introduction
Piotr Mazur 1 2-95 - Chapter 9 THE EFFECT OF THERMAL TRANSFORMATIONS ON THE MELT MASS-FLOW RATE AND THE MELT VOLUME-FLOW RATE OF ABS Abstract: The melt mass-flow rate and the melt volume-flow rate determine
More informationEES Energy Efficient Systems Rotary Screw Air Compressors kw Horsepower
S-energy EES Energy Efficient Systems Rotary Screw Air Compressors 30-75 kw 40-100 Horsepower Superior energy savings Payback in less than 2 years 90% of wasted heat is recoverable Excellent source of
More informationUsing Software and Submeters to Manage Energy
Dan Ellis Product Manager Power Management Products Eaton s Cutler-Hammer business Introduction To be economically competitive in today s global marketplace, it is necessary to reduce the cost of production
More information