1 Abu Dhabi Trade Effluent Standards & Regulations Summary August 2010 Disclaimer: The standards & regulations provided here are attributable to the named source and are assumed to be accurate at the time of posting. This information was assembled by us as a service to our customers, but has not been independently verified or confirmed. 1
2 Trade Effluent Definition Trade effluent is defined as wastewater discharged to a sewerage system which is produced in the course of any industrial, commercial, agricultural, medical, scientific or trade activity, but does not include domestic wastewater. 2
3 Trade Effluent Discharge Characterization Chart Is Discharge from a Trade Effluent Activity? Does the Discharge Does discharge comprise any substances at pose a low risk to concentrations greater the Wastewater than typical domestic wastewater or Collection Systems? flows greater than typical domestic developments? Low risk Trade Effluent Domestic Discharge Commercial Discharge Full Trade Effluent No consent required Consent required 3
4 Trade Effluent Control Regulations 2010 Framework Low risk Trade Effluent 4
5 Impact Assessment Process (Sewerage System) Prohibited Wastes? Prohibited waste not allowed Risk of Explosion? Volatile Substances? Hazardous to Health? Standards to protect health Obstructing Substances? Standards to protect sewer system Standards to control odor potential 5
6 Impact Assessment Process (Treatment System) Any biological toxicity issues? TE Standards to minimize treatment toxicity Is TE biologically degradable? TE Standards to match capacity of Treatment Systems Standards to protect health Accumulation in sludge stream? Any anaerobic toxicity issues? TE Standards to minimize treatment toxicity 6
7 Impact Assessment Process (Disposal System) Recycled Water & Bio-solids toxic to the environment? Recycled Water & Bio-solids degradable in environment? TE Standards to meet environmental obligations Is TE biologically degradable? Refer to EAD 7
8 Substances to Be Limited Prior to Discharge to Sewer Substance Unit Maximum Allowable Characteristic Chemical Oxygen Demand mg/l 1000 Total Suspended Solids mg/l 500 Total Dissolved Solids mg/l 3000 Temperature C 45 ph unit >6 and <9 Grease & oil (hydrocarbon) mg/l 60 Grease & oil (non-hydrocarbon) mg/l 100 Max physical size of non fecal matter mm 15 Chloride (as Cl - ion) mg/l 1000 Cyanide mg/l 2 8
9 Substances to Be Limited Prior to Discharge to Sewer (Cont d.) Substance Unit Maximum Allowable Characteristic Fluoride (as F - ion) mg/l 15 Sulfate (as SO 4 ) mg/l 1000 Sulfide (as S) mg/l 2 Total Kjeldahal Nitrogen mg/l 15 Total Phosphorous mg/l 1000 Detergents mg/l 1 Phenolic Compounds (as Phenol) mg/l 150 Polycyclic Aromatic Hydrocarbons mg/l 50 Organophosphrus Pesticides mg/l 30 Organophochlorine Pesticides mg/l 0.5 9
10 Substances to Be Limited Prior to Discharge to Sewer (Cont d.) Substance Unit Maximum Allowable Characteristic Aluminum mg/l 100 Arsenic mg/l 5 Barium mg/l 10 Beryllium mg/l 5 Boron mg/l 5 Cadmium mg/l 1 Chromium mg/l 5 Cobalt mg/l 5 Copper mg/l 5 Iron mg/l 50 10
11 Substances to Be Limited Prior to Discharge to Sewer (Cont d.) Substance Unit Maximum Allowable Characteristic Lead mg/l 5 Lithium mg/l 2.5 Manganese mg/l 10 Mercury mg/l 0.5 Molybdenum mg/l 10 Nickel mg/l 10 Selenium mg/l 10 Silver mg/l 5 Tin mg/l 10 Vanadium mg/l 1 Zinc mg/l 10 11
12 12
Acceptance standards and charging rates for
Industrial customers Acceptance standards and charging rates for 2017-18 Sydney Water accepts trade wastewater to the wastewater system, if it meets certain acceptance standards. What are acceptance standards?
More informationLABORATORY TURNAROUND TIMES AND CHARGES
LABORATORY TURNAROUND TIMES AND CHARGES The enclosed prices reflect a 5 business day turnaround time. There will be a $25.00 minimum charge per report. Same Day Rush 24 Hour Rush 48 Hour Rush 72 Hour Rush
More informationCATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS. The temperature shall not exceed 28 degrees Celsius.
Updated 21 Dec. 2005 CATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS 1 PHYSICAL CHARACTERISTICS (a) Temperature The temperature shall not exceed 28 degrees Celsius. (b) Solids The suspended solids concentration
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationENVIRONMENTAL LABORATORY LICENSE. ACZ Laboratories, Inc. AZ0102
ARIZONA DEPARTMENT OF HEALTH SERVICES ENVIRONMENTAL LABORATORY LICENSE Issued to: Laboratory Director: Owner/Representative: Brett Dalke Matt Sowards ACZ AZ0102 is in compliance with Environmental Laboratory
More informationNewmont Mining Corporation Water Management Standard
Page No: Page 1 of 5 1 PURPOSE AND OBJECTIVES This Global Standard sets the minimum Newmont requirements to proactively plan and manage water from exploration to post-closure in accordance with Newmont
More informationSILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/
6360 Gateway Drive, 90630 95073 Page 1 of 8 CI-516 Cistanche 361439388 ICP MS Full Mineral Screen EPA 3050/6020 USP730 BRN Aluminum 2.2 ppm (w/w) Antimony Arsenic 0.06 ppm (w/w) Barium 0.09 ppm (w/w) Beryllium
More informationFORM 26R CHEMICAL ANALYSIS OF RESIDUAL WASTE ANNUAL REPORT BY THE GENERATOR INSTRUCTIONS GENERAL INFORMATION
COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF WASTE MANAGEMENT FORM 26R CHEMICAL ANALYSIS OF RESIDUAL WASTE ANNUAL REPORT BY THE GENERATOR INSTRUCTIONS GENERAL INFORMATION
More informationSTATE ENVIRONMENTAL LABORATORY SERVICES DIVISION
STATE ENVIRONMENTAL LABORATORY SERVICES DIVISION FY18 ANALYTICAL FEE SCHEDULE Adjusted to correspond with Consumer Price Index (CPI) of 1.013 APPENDIX A. SAMPLES SUBMITTED BY GOVERNMENT ENTITIES Gas Chromatography/Mass
More informationWaste Discharge Permit Application. for. Commercial, Industrial and Institutional Discharges
Waste Discharge Permit Application for Commercial, Industrial and Institutional Discharges This is an application for a Waste Discharge Permit under the City of Prince George Sanitary Sewer Bylaw # 7897
More informationMicro Methods Laboratory Quality Assurance Manual
15.2 List of Approved Methods Petroleum Analysis Methodology Reference Table Method ASTM 977 ASTM C25 ASTM C39 ASTM D129 ASTM D1298 ASTM D156 ASTM D1744 ASTM D189 ASTM D2159 ASTM D2270 ASTM D2276 ASTM
More informationDrinking Water Analyses
Environmental & Analytical Services 350 Hills Street, Suite 107, Richland, WA 99354 (509) 377-8058 FAX (509) 377-8464 ANALYSES AND PRICE LIST, JANUARY 2016 TO DECEMBER 2016 Drinking Water Analyses BACTERIOLOGICAL
More informationKKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationWater and Waste Water Management in Yangon, Myanmar
Union of Myanmar Ministry of Agriculture and Irrigation Irrigation Department Water and Waste Water Management in Yangon, Myanmar Mu Mu Than Staff Officer, Irrigation Department Myanmar March,2010 Socio-economical
More informationICP/ICP-MS Standards. High Purity Standards for ICP/ICP-MS
ICP/ICP-MS Fisher Brand AA/ICP MS Fisherbrand ICP/ICP-MS Catalog No. Catalog No. Concentrationion Size ml Concentration Size ml 36 102 7820 Aluminum 36 102 7821 Antimony 36 102 7823 Arsenic 36 102 7824
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MICROBAC LABORATORIES, INC., KTL DIVISION 3323 Gilmore Industrial Blvd. Louisville, KY 40213 Megan Rothgerber Phone: 502 962 6400 CHEMICAL Valid To: December
More informationKirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent
Kirill Ukhanov, GE Water & Process Technologies, Russia, describes how advanced membrane technology is helping a Russian refinery to meet stringent wastewater requirements. In Russia, there are strict
More informationTolerance and Classification
Tolerance and Classification As per ISI-IS: 2296-1982, the tolerance limits of parameters are specified as per classified use of water (Table 1,2,3,4,5 below) depending on various uses of water. The following
More informationSUMMARY OF FEDERAL PRETREATMENT STANDARDS CENTRALIZED WASTE TREATMENT CATEGORY. Within U.S.: 165
SUMMARY OF FEDERAL PRETREATMENT STANDARDS CENTRALIZED WASTE TREATMENT CATEGORY Applicable CFR: 40 CFR Part 437 Estimated Number of Companies Affected: Within U.S.: 165 Proposal in Federal Register: January
More informationWaste Discharge By-law
Waste Discharge By-law WM-16 Consolidated March 29, 2010 This by-law is printed under and by authority of the Council of the City of London, Ontario, Canada Disclaimer: The following consolidation is an
More informationRemoving Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 Removing Heavy Metals From Wastewater Introduction This manual provides
More informationFinal Report DMR-QA 36. NPDES Permit: IL DMR-QA Study. Open Date: 03/18/16. Close Date: 07/01/16. Report Issued Date: 07/29/16
Keith Richard Decatur Sanitary District Decatur, IL 62522-1842 USA DMR-QA 36 Final Report NPDES Permit: IL0028321 DMR-QA Study Open Date: 03/18/16 Close Date: 07/01/16 Report Issued Date: 07/29/16 Study
More informationAppendix C1: Batch Kinetics Tests
Appendix C1: Batch Kinetics Tests This appendix contains the entire data set for the batch kinetics tests for the potential biofilter components. These tests were performed to provide estimates of optimal
More information4.0 SAN GABRIEL RIVER WATERSHED MANAGEMENT AREA
4.0 SAN GABRIEL RIVER WATERSHED MANAGEMENT AREA 4.1 Watershed Description 4.1.1 Watershed Land Use, Percent Impervious, and Population Land use in the San Gabriel River Watershed Management Area is approximately
More informationRational IPP Permitting
Rational IPP Permitting Protect POTW/Environment and Promote Local Economy FISHBECK, THOMPSON, CARR, & HUBER INC. Jerald O. Thaler, PE MWEA IPP Seminar October 6, 2016 Rational IPP Permitting? Accurate/Up-to-Date
More informationWASTE ACCEPTANCE CRITERIA
KIRBY CANYON RECYCLING & DISPOSAL FACILITY WASTE ACCEPTANCE CRITERIA Kirby Canyon Recycling & Disposal Facility Highway 101 at Coyote Creek Golf Drive Exit 910 Coyote Creek Golf Drive Morgan Hill, CA 95037
More informationMagino Project Environmental Impact Statement. Technical Support Document Environmental Monitoring Plan
Magino Project Environmental Impact Statement Technical Support Document 20-13 Rev. No. Revision Date Approved 0 Document issued for EIS Table of Contents SECTION 1.0 Purpose of the Plan... 1 1.1 Scope
More informationCANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT
CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT WATER QUALITY ASSESSMENT OF Salmon River AT SALMON ARM (1985 24) Prepared by: L. G. Swain, P. Eng. B.C. Ministry of Environment Prepared for:
More informationWHERE DO THE PRETREATMENT PERMIT LIMITS COME FROM??? Amy Varinoski City of Mebane
WHERE DO THE PRETREATMENT PERMIT LIMITS COME FROM??? Amy Varinoski City of Mebane AND MOST IMPORTANTLY. ARE YOU MEETING YOUR CURRENT PRETREATMENT PERMIT LIMITS? IF NOT, CAN YOUR COMPANY PARTICIPATE IN
More informationCANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT
CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT WATER QUALITY ASSESSMENT OF Thompson River AT SPENCES BRIDGE (1984 24) Prepared by: L. G. Swain, P. Eng. B.C. Ministry of Environment Prepared
More information~ '2::5 - SUZANNE BLANCAFLOR, MS, MPH CHIEF, ENVIRONMENTAL HEAL TH SECTION D,!>~) STATE OF CONNECTICUT. Eurofins Lancaster Labs Environmental, LLC
D,!>~) ~ ( Ollnf(t vll>
More informationDR 1900 PORTABLE SPECTROPHOTOMETER
DR 1900 PORTABLE SPECTROPHOTOMETER Applications Drinking Water Wastewater Field Use Industrial Water Power Carry more water methods with you wherever you need them most. The DR 1900 combines the ruggedness
More informationGENERAL PERMIT WMGR098 BENEFICIAL USE OF WASTE FOUNDRY SAND AND SAND SYSTEM DUSTS
A. Description: The approval herein granted is limited to the beneficial use of waste foundry system sand and sand system dusts (hereinafter referred to as waste foundry sand) generated by ferrous metal
More informationTable 1. VOCs Detections (all data in µg/l)
AMBIENT WATER QUALITY IN THE UPPER GLACIAL AQUIFER NEAR THE TOWN OF BROOKHAVEN LANDFILL, SUFFOLK COUNTY, NEW YORK David J. Tonjes Waste Reduction and Management Institute Marine Sciences Research Center
More informationJordan Water Company/ Miyahuna Production and Quality Directorate Quality Control and Assurance Department Service Price List
Service List 1 Color Color Materials/Products Tested: Water (Surface, Ground, Effluent & Distributed Water) PHYSICAL TESTS SM 1 B - Visual Comparison Method - Standard Method for Examination of Water and
More informationNotification of Department of Industrial Works
tification of Department of Industrial Works Subject: Type or category of factory required to prepare a report of type and quantity of pollutants discharged from a factory B.E. 2553 (2010) It is deemed
More informationLABORATORY ACTIONS, DECISIONS & SAFETY WITHIN THE EUROPEAN UNION
LABORATORY ACTIONS, DECISIONS & SAFETY WITHIN THE EUROPEAN UNION Kardzhali,, 7-9 7 9 December 2012 Research Center Environment and Health-Regional Health inspectorate George Papageorgiou Chemical Analyst
More informationLOCAL LIMITS METHODOLOGY,, ISSUES,, AND ALTERNATIVES
Presented to: Southern California Alliance of POTWs LOCAL LIMITS METHODOLOGY,, ISSUES,, AND ALTERNATIVES Barbara Sharatz September 25, 2012 Overview of Presentation Background Pollutants of Concern (POCS)
More informationCLEAN WATER Clean Water PT Scheme Schedule Clean Water PT Scheme Schedule. Schedule subject to change see ERA s website at
For International purchase only: Synthetic drinking water matrices with low concentrations of analytes for testing water supply, drinking water, or ground water. Standards are designed to meet the requirements
More informationReasonable Potential Analysis & Impacts to Pretreatment Programs. Raj Kapur Clean Water Services
Reasonable Potential Analysis & Impacts to Pretreatment Programs Raj Kapur Clean Water Services Agenda Water Quality Standards (WQS) & Recent Changes Reasonable Potential Analysis Pollutants of Concern
More informationUrban Area Polycyclic Aromatic Hydrocarbons Study Tiered Approach to Corrective Action Objectives
Urban Area Polycyclic Aromatic Hydrocarbons Study Tiered Approach to Corrective Action Objectives Two background studies were recently completed investigating certain polycyclic aromatic hydrocarbon (PAHs)
More information06. Electroplating Industry
PRTR Estimation Manual 06. Electroplating Industry January 2001 Revised: March 2002 Federation of Electro Plating Industry Association, Japan Contents 1. Class I Designated Chemical Substances (Referred
More informationAP Chemistry Reaction Set
Class: Date: AP Chemistry Reaction Set 2008-2009 Other 1. Sulfur trioxide gas is bubbled into a solution of sodium hydroxide. (2005) 2. Hydrogen iodide gas is bubbled into a solution of lithium carbonate.
More informationCANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT
CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT WATER QUALITY ASSESSMENT OF KETTLE RIVER AT MIDWAY (1972 2) Prepared by: BWP Consulting Kamloops, B.C. January, 23 Environment Canada Environnement
More informationThe Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption
The Determination of Toxic Metals in Waters and Wastes by Furnace Atomic Absorption Application Note Atomic Absorption Authors Douglas E. Shrader Lucinda M. Voth Lawrence A. Covick Introduction With the
More informationJordan Water Company/ Miyahuna. Quality, Laboratories and Water Safety Department. Service Price List
Materials/Products Tested: Water (Surface, Ground, Effluent & Distributed Water) 1 Turbidity (Lab) 3 Turbidity (Field Test) 4 Odor 5 Total Alkalinity 6 Phenolphthalein Alkalinity 7 Total Hardness 8 9 Electrical
More informationSVCW Use: City: State: Zip Code: Phone:
SILICON VALLEY CLEAN WATER1400 Radio Road, Redwood City, CA 94065 (650) 591-7121 Application For Wastewater Discharge Permit Part A Sewer User Identification This application must be printed or typewritten.
More informationCorrosion Studies on GeoBrom HG520
Corrosion Studies on GeoBrom HG520 Partial Immersion Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive
More informationInorganic Chemicals (IOCs)
Burlington WA Corporate Office 1620 S Walnut St - 98233 800.755.9295 $ 360.757.1400 Bellingham WA Microbiology 805 Orchard Dr Ste 4-98225 360.671.0688 Portland OR Microbiology/Chemistry 9150 SW Pioneer
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationINCHEM Tokyo Current Status and Implementation Approach for Industrial Zones Wastewater Management In Yangon Region
INCHEM Tokyo 2017 Current Status and Implementation Approach for Industrial Zones Wastewater Management In Yangon Region Than Than Thwe Director, Ministry of Construction Joint Secretary-1, Thilawa SEZ
More informationTOWN OF HASTINGS, FLORIDA TOWN CODE. Chapter 18. Previous Page. Water and Sewer. Article II. Sewers -- Prohibited Discharges.
TOWN OF HASTINGS, FLORIDA TOWN CODE Chapter 18 Previous Page Water and Sewer Article II Sewers -- Prohibited Discharges. Sec. 18-20. General Prohibition No Person shall discharge or cause to be discharged
More informationNomenclature. A systematic method of writing chemical formulas and naming compounds
Nomenclature A systematic method of writing chemical formulas and naming compounds Chemical symbols Symbols are used to represent elements Either one capital letter, or a capital letter with a lower case
More informationAP Chemistry Reaction Set
Class: Date: AP Chemistry Reaction Set 2009-2010 Other 1. Pure solid phosphorus (white form) is burned in air. (2002) 2. Sulfur dioxide gas is bubbled into distilled water. (2001) 3. A drop of potassium
More informationEnergy Northwest Environmental Services Lab
Energy Northwest Environmental Services Lab Drri innkki inngg Waatteerr Annaal lyysseess BACTERIOLOGICAL ANALYSES 350 Hills Street, Suite 107, Richland, WA 99354 (509) 377-8058 FAX (509) 377-8464 ANALYSES
More informationSUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000
SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 100 Fe 200 *** Fe 250 *** Fe 300 Fe 400 Fe 500 Fe 000 Fe low alloy steel cast iron Cr hard / Ni resist stainless steel tool
More informationWASTEWATER DISCHARGE PERMIT APPLICATION SHORT FORM
WASTEWATER DISCHARGE PERMIT APPLICATION SHORT FORM * * * * * * * * * * * RETURN TO: NARRAGANSETT BAY COMMISSION PRETREATMENT SECTION 2 ERNEST STREET PROVIDENCE, RHODE ISLAND 02905 (401) 461-8848 (401)
More informationSTATE OF CONNECTICUT
-------------------------------------- STATE OF CONNECTICUT DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ENVIRONMENTAL LABORATORY CERTIFICATION PROGRAM CERTIFIED ANAL YTES REPORT FOR ALL MATRICES
More informationKits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT
Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ENVIRONMENTAL CONSERVATION LABORATORIES JACKSONVILLE 4810 Executive Park Court, Suite 111 Jacksonville, FL 32216 Lori S. Mangrum Phone: 904 296 3007 Email address:
More informationCombined Sewer Overflows July 2012-December 2013
CSO Facilities Summary Report 213 Combined Sewer Overflows July 212-December 213 Overview MWRA monitored four CSO facilities in the North System during the period covered in this report (July 212 December
More informationA.M. MONDAY, 18 January minutes
Candidate Name Centre Number Candidate Number 0 GCSE 240/01 ADDITIONAL SCIENCE FOUNDATION TIER CHEMISTRY 2 A.M. MONDAY, 18 January 2010 45 minutes ADDITIONAL MATERIALS In addition to this paper you may
More informationTreated Municipal Wastewater Irrigation Guidelines EPB 235
Treated Municipal Wastewater Irrigation Guidelines EPB 235 JAN 2014 1. Introduction 1.1 General The purpose of this guideline is to assist the owners of wastewater treatment works and consultants considering
More informationExact Scientific Services, Inc. Ferndale, WA
Ferndale, WA has complied with provisions set forth in Chapter 173-50 WAC and is hereby recognized by the Department of Ecology as an ACCREDITED LABORATORY for the analytical parameters listed on the accompanying
More informationCERTIFICATE OF ANALYSIS REVISED REPORT
Your C.O.C. #: A122303 Attention: STEPHEN LEGAREE EDMONTON 9331 9331-48 Street EDMONTON, AB CANADA T6B 2R4 Report #: R1787645 Version: 2R CERTIFICATE OF ANALYSIS REVISED REPORT MAXXAM JOB #: B4B4991 Received:
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK B229 Contact: Ms Jill French Analytical Services Tel: +44 (0)19467 87408 Sellafield Fax: +44 (0)19467 75154 Cumbria E-Mail: jill.x.french@sellafieldsites.com
More informationDECREE OF THE STATE MINISTER FOR POPULATION AND ENVIRONMENT NUMBER: KEP-03/MENKLH/II/1991 RE: EFFLUENT QUALITY STANDARDS FOR EXISTING OPERATIONS
DECREE OF THE STATE MINISTER FOR POPULATION AND ENVIRONMENT NUMBER: KEP-03/MENKLH/II/1991 RE: EFFLUENT QUALITY STANDARDS FOR EXISTING OPERATIONS THE STATE MINISTER FOR POPULATION AND ENVIRONMENT: Considering:
More informationClyde Mine Discharge/Tenmile Creek Water Quality Final Report
Clyde Mine Discharge/Tenmile Creek Water Quality Final Report November 01, 2016 Background In follow-up to the Pennsylvania Department of Environmental Protection s (DEP) December 15, 2015, Tenmile Creek
More informationJEDDAH INDUSTRIAL CITY
JEDDAH INDUSTRIAL CITY WASTEWATER TREATMENT PLANT A Presentation by : Engr. Mowafaq Al-Sugeir Managing Director ICDOC SAWEA 2007 WORKSHOP, AL-KHOBER 4 December 2007 Built & Being Operated by : on Build-Operate-Transfer
More informationADDENDUM #004. Laboratory Analysis on Water Treatment Plants, Wastewater Treatment Plants, and Groundwater Wells
ADDENDUM #004 Solicitation Number: Solicitation Title: Opening Date/Time: FDC ITB-15-142 Laboratory Analysis on Water Treatment Plants, Wastewater Treatment Plants, and Groundwater Wells December 8, 2016
More informationEXPORT SOIL-MATERIAL QUALITY REQUIREMENTS
EXPORT SOIL-MATERIAL QUALITY REQUIREMENTS GENERAL Industrial operations have been conducted on Port of Long Beach property since the 1930s. Though it is unlikely that hazardous substances will be encountered
More informationMidwest Analytical Services, Inc. "Where industry comes for answers." PRICE LIST 2009
PRICE LIST 2009 Midwest Analytical Services, Inc. (MAS) takes pride in its commitment to provide reliable and valid analytical data to customers. Our staff at MAS is active in a comprehensive QA/QC program
More informationBLACK STURGEON LAKES WATER QUALITY MONITORING
BLACK STURGEON LAKES WATER QUALITY MONITORING 2017 REPORT Prepared by: Ryan Haines, B.Sc. Biologist and Project Management Kenora Resource Consultants Inc. Site 155, Compartment 14, RR #1 Kenora, ON P9N
More informationWater Quality Permitting Program Monitoring Matrix 1,2,3
State of Oregon Department of Environmental Quality Water Quality Permitting Program Monitoring Matrix 1,2,3 ITEM OR PARAMETER Total Flow (influent and/or effluent) 4 Flow Meter Calibration 5 (influent
More informationGeneral Information on Nitrogen
General Information on Nitrogen What is nitrogen? Nitrogen was discovered in 1772 by Daniel Rutherford in Scotland Nitrogen gas makes up nearly 80% of the air we breathe Nitrogen gas is not toxic Nitrogen
More informationNo user shall introduce or cause to be introduced into the POTW the following pollutants, substances, or wastewater:
SECTION 30.03 - PRETREATMENT OF WASTEWATER 1. Prohibited Discharge Standards General Prohibitions (i) (ii) No user shall introduce or cause to be introduced into the POTW any pollutant or wastewater, which
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: i54 Business Park Valiant Way Wolverhampton
More informationDouglas G. Brookins. Eh-pH Diagrams. for. Geochemistry. With 98 Figures and 61 Tables. Springer -Verlag Berlin Heidelberg New York London Paris Tokyo
Douglas G. Brookins Eh-pH Diagrams for Geochemistry With 98 Figures and 61 Tables Springer -Verlag Berlin Heidelberg New York London Paris Tokyo Dr. Douglas G. Brookins Department of Geology University
More informationLecture 2, Part 1, Conceptual Site Models for Exposure Assessment
Lecture 2, Part 1, Conceptual Site Models for Exposure Assessment Conrad (Dan) Volz, DrPH, MPH Assistant Professor, Environmental and Occupational Health, University of Pittsburgh, Graduate School of Public
More informationMinisterial Decision No: 159/2005 Promulgating the bylaws to discharge liquid waste in the marine environment
Sultanate of Oman Ministry of Regional Municipalities, Environment & Water Resources Minister s Office Muscat Ministerial Decision No: 159/2005 Promulgating the bylaws to discharge liquid waste in the
More informationContaminated Extraction Pit treated to allow dewatering for continuation of mining works
Contaminated Extraction Pit treated to allow dewatering for continuation of mining works Name Customer name withheld Site Location South East Queensland Site Problem ph, Acidity and Dissolved Metals Water
More informationCompounds & Reactions Week 1. Writing Formulas & Balancing Equations. Write the chemical formula for each molecular (covalent) compound.
Compounds & Reactions Week 1 Name Writing Formulas & Balancing Equations Write the chemical formula for each ionic compound. 1. Lithium fluoride 2. Copper (II) chloride 3. Manganese (II) oxide 4. Potassium
More informationSAMPLE CHAPTERS UNESCO EOLSS WATER SUPPLY FOR AGRICULTURE
WATER SUPPLY FOR AGRICULTURE S. Ya. Bezdnina All-Russian Scientific Research Institute of Hydraulic Engineering and Land Reclamation, Russian Academy of Agricultural Sciences, Moscow, Russia Keywords:
More informationA.M. MONDAY, 18 January minutes
Candidate Name Centre Number Candidate Number 0 GCSE 240/02 ADDITIONAL SCIENCE IGER TIER CEMISTRY 2 A.M. MONDAY, 18 January 2010 45 minutes ADDITIONAL MATERIALS In addition to this paper you may require
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9
Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %
More informationDevelopment of Soil-to-Terrestrial Invertebrate Uptake Factors to Improve Estimation of Ecological Risk on DFO Lightstation Sites in Atlantic Canada
Development of Soil-to-Terrestrial Invertebrate Uptake Factors to Improve Estimation of Ecological Risk on DFO Lightstation Sites in Atlantic Canada May 2012 BACKGROUND ERA for Lightstation Sites in Atlantic
More informationCouncil Directive 91/689/EEC of 12 December 1991 on hazardous waste
Council Directive 91/689/EEC of 12 December 1991 on hazardous waste Official Journal L 377, 31/12/1991 P. 0020-0027 Finnish special edition: Chapter 15 Volume 10 P. 0199 Swedish special edition: Chapter
More informationTXTB L bas-cen
Seite 1 von 8 31991L0689 Council Directive 91/689/EEC of 12 December 1991 on hazardous waste Official Journal L 377, 31/12/1991 P. 0020-0027 Finnish special edition: Chapter 15 Volume 10 P. 0199 Swedish
More informationCorrosion Studies on GeoBrom HG520
Corrosion Studies on GeoBrom HG520 Vapor Space Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive
More informationCorrosion Studies on GeoBrom HG520
Corrosion Studies on GeoBrom HG520 Total Immersion Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive
More informationWASTEWATER PRACTICES: MERCURY DISCHARGE Introduction
WASTEWATER PRACTICES: MERCURY DISCHARGE Introduction Mercury may be found in many products in use at Harvard University including lab chemicals, wastewater treatment chemicals and cleaning supplies and
More informationDrinking Water Quality and Compliance SaskWater Wakaw-Humboldt Potable Water Supply System and Treatment Plant 2016 Notification to Consumers
Drinking Water Quality and Compliance SaskWater Wakaw-Humboldt Potable Water Supply System and Treatment Plant 2016 Notification to Consumers The Water Security Agency (WSA) requires that, at least once
More informationSewer Charge & Surcharge Provision Development, Implementation & Benefits
Sewer Charge & Surcharge Provision Development, Implementation & Benefits 2013 Industrial Wastewater Conference Bethlehem, PA (October 4, 2013) Human Waste Treatment History (1) Historically dilution in
More informationDRAFT OHIO EPA INDUSTRIAL STORMWATER GENERAL PERMIT. I. Comparison with Existing General Permit (OHR000004)
DRAFT OHIO EPA INDUSTRIAL STORMWATER GENERAL PERMIT I. Comparison with Existing General Permit (OHR000004) A. See attached comparison chart courtesy of Curt Spence, Spence Environmental Consulting, Inc.
More informationEvaluation of Pollutants in Wastewater Generated by Mobile Car Washing Operations
Evaluation of Pollutants in Wastewater Generated by Mobile Car Washing Operations City of Durham Public Works, Stormwater t Services Maverick Raber, Matt Smith, John Cox, Michelle Woolfolk Public Works
More informationSPE SPE PP. Woodford Completion Operations
SPE SPE-121104-PP Breakthrough Mobile Water Treatment Converts 75% of Fracturing Flowback Fluid to Fresh Water and Lowers CO 2 Emissions Aaron D. Horn / Newfield Exploration Mid-Continent Copyright 2009,
More informationStatic Detonation Chamber Status Update
Static Detonation Chamber Status Update 26 May 2017 Presented to: The 20 th Annual International Chemical Weapons Demilitarisation Conference Presented by: Tim Garrett Anniston Site Project Manager APPROVED
More informationWASTEWATER DISCHARGE PERMIT APPLICATION RESTAURANT & FOOD PREPARATION ESTABLISHMENTS
WASTEWATER DISCHARGE PERMIT APPLICATION RESTAURANT & FOOD PREPARATION ESTABLISHMENTS * * * * * * * * * * * RETURN TO: NARRAGANSETT BAY COMMISSION PRETREATMENT SECTION 2 ERNEST STREET PROVIDENCE, RHODE
More informationBiosolids Monthly Report
July-September 217 Biosolids Monthly Report Submitted By: Biosolids Management Program Team Wastewater Treatment Facility 14 Brander St. Richmond, VA 23224 Figure 1: the deputy director Ms. Rosemary Green
More information