Energy Audit Report Carnoustie Golf Links (CGLMC)

Size: px
Start display at page:

Download "Energy Audit Report Carnoustie Golf Links (CGLMC)"

Transcription

1 Energy Audit Report Carnoustie Golf Links (CGLMC) Compiled by Orchard Ltd Page 1 of 15

2 audit contents Section 1: Customer and Adviser Details 3 Section 2: Executive Summary 4 Section 3: Current Energy Consumption 6 Section 4: Introduction 7 Section 5: Background to Recommendations 10 Section 6: Savings Opportunities 11 Understand the heating systems Assessment of recommendations from the report of 2012 Investigate reports of lack of hot water in the showers Automatic lighting controls in Pro Centre Illustration of alternative heating systems for Greenkeeping Complex Compiled by Orchard Ltd Page 2 of 15

3 1 Customer and Energy Adviser Contact name Sandy Reid Contact job title Links Superintendent Phone Mobile Dates of visits 2 nd June 2015 Lead Assessor Colin Porteous Phone e_solutions@orchardenergy.co.uk Compiled by Orchard Ltd Page 3 of 15

4 2 Executive Summary Carnoustie Golf Links have a number of properties on and around the two golf courses at Carnoustie. Concerned with the continually rising cost of energy, the links management group, CGLMC commissioned an energy audit in 2012, which highlighted a number of issues, but did not make any quantitative conclusions. At that time, many of the findings related to energy management and operation of the various systems on the sites. There are four separate sites: The Golf Centre The Greenkeepers Complex, (also called South America) The Starter s Box The Office building In the period since then, Orchard Energy were commissioned to look again at energy use, to pick up on certain issues from the original audit and to include other opportunities, like renewable energy. The author then visited the site and gained a clearer understanding of these issues, which enabled a more focussed agenda of items to be covered: Understand how the various heating systems interact with one another at the Golf Centre. Propose energy saving measures in the Golf Centre and the Greenkeepers Complex. Much of these will be behavioural. Investigate why there have been reports of lack of hot water at some busy times. Install automatic lighting controls in the reception area under the atrium and in the locker rooms. Propose an illustration of alternative biomass and gas conversions for the Greenkeepers Complex. The recommendations arising from this report are detailed below and include behavioural/operational changes, a summary of costs associated with the recommendations of the previous report, a statement on the hot water shortfall investigations, energy saving measures at the Greenkeepers Complex and illustrations of this location. Most of the savings will come from improvements which can be implemented without great expense or disruption to the golf club s activities. The request to make recommendations on alternative heating systems at the Greenkeepers complex will require a capex commitment although this may be supported by government incentives. The potential annual savings amount to 29,000 per year if the proposal for biomass heating at the Greenkeepers complex is adopted. It is important to note that the alternative heating project costs are based on illustrative figures only, as there is no record of separate oil costs for heating there. Before proceeding with this, it is important to record the fuel actually being used in the boiler and the workshop convector. This will require the delivery drivers to segregate quantities going into the heating tank from what goes into the machinery filling tanks. A summary of these savings is shown on page 5. Compiled by Orchard Ltd Page 4 of 15

5 Photograph of the atrium from inside Savings Summary Table No. Recommendation Cost Saving ( ) Cost to implement ( ) 1 Understanding the Pro Centre 3,750 1, heating systems 2 Assessment of recommendations 10,980 5, from previous report 3 Investigation of lack of hot water 4 Install automatic lighting controls 5 Alternative heating systems at 4,500 35, Greenkeepers complex - gas 5 Alternative heating systems at Greenkeepers complex biomass 14, , Total (assuming biomass conversion) 29, , Pay-back period (yrs) Compiled by Orchard Ltd Page 5 of 15

6 3 Current Energy Consumption Utility Electricity at Pro Centre Cost Energy Consumption CO2 Emissions ( /year) (kwh/yr) (Tonnes) 19, , Electricity at 15, , Greenkeepers Gas at Pro Centre Unknown Unknown unknown Oil at Greenkeepers Complex Totals for electricity only Unknown Unknown Unknown 34, , Unit costs used in calculating energy savings: Electricity 12.61p/kWh, Gas unknown Compiled by Orchard Ltd Page 6 of 15

7 4 Introduction Carnoustie Golf Links is a long-established club located on the east coast of Scotland. Golf has been played at this location for at least two hundred years and buildings associated with the game have been present for most of that time. This report considers two current buildings, the Pro Centre and the greenkeepers complex. The Pro Centre was built only four years ago and the main greenkeepers building is reported to be seven years old. The Links Superintendent took time to show the author around the buildings and it was clear that the two buildings have very different issues relating to energy. The Pro Centre This is mostly a single storey building with a central atrium containing a small number of rooms around it on the upper storey. The atrium has good natural light through upper level windows. There is both an underfloor heating system and a mechanical ventilation system. There is a building management system to control these systems. There is no on-site knowledge of how these systems are meant to work. Maintenance is carried out by external contractors and many of the original settings have been lost. The Links Superintendent has adopted the role of coordinator to try and improve the situation. Attempts to engage any of the original design team have been thwarted to date, as most of the companies involved have since gone out of business. Fortunately, during the course of the investigations, a retired member of the design consultants was found and there is a strong recommendation in this report to engage him to supervise recommissioning of the systems and train users in how they should be operated. Energy Use The building has a complex heating and ventilating arrangement. A heat pump is used to supply a ground-floor underfloor heating system. Two gas-fired condensing LT hot water boilers provide heat to six air-handling units and backup heat to the heat pump buffer tank. In addition, hot water is generated by a once-through Andrews water heater. Complaints were reported that the showers run out of hot water during busy periods on match days or during wet weather. A logging exercise was carried out over a month in the summer to record water temperature, however, at no point did the temperature fall below 59oC, so it is not obvious what the problem is. During this period, in addition to clients use of the shower, there routine Legionella tests carried out where all the showers are run at maximum flow and temperature for an extended period and again the flow temperature did not show any departure from normal. Staff have been asked to alert the Links Superintendent immediately if there is a recurrence, so that flow and temperature conditions can be measured. Compiled by Orchard Ltd Page 7 of 15

8 Photographs of the air source heat pump and underfloor heating controls Lighting Lighting is by a mixture of T5 fluorescent lamps and LEDs. Artificial lighting around the atrium is provided by 40 T5s and all were on during the visit, despite strong natural light from the atrium windows. There is an opportunity to install daylight/movement sensors here and in the locker rooms which can see extended periods of low occupancy, with lights left on. It is recommended that this programme is continued as most lights in the building have high load factors due to the long daily hours they are in service. The Greenkeepers Complex This building has two storeys built around a large workshop where the course machinery is stored and maintained. The building is of conventional construction and has a pitched roof. There are offices and meeting rooms on the upper floor. Windows are all double-glazed. There is an oil-fired boiler, which supplies a wet system around the offices and other rooms. It is a relatively new boiler and it appears to work well. The main issue is the cost of fuel oil and CGLMC are keen to explore alternatives. Around the main building there are two other buildings and a café which serves the golfers. These other buildings are all electrically heated and if an economic solution can be found for heating the main building it could be extended to form a small district heating system to include these other buildings. Both gas and biomass are feasible alternatives. Compiled by Orchard Ltd Page 8 of 15

9 Photograph of the oil-fired boiler Lighting is generally by T5 fluorescent lighting in the offices and T8s in the workshop and one of the smaller sheds. It is heated by a large standalone, oilfired warm air convector. This too could be replaced by a fan convector supplied from a district heating system in the event that a decision is taken to install such a system. There is a good-sized roof for solar pv panels, however, it is mostly south-facing, so would be suitable, but there is a strong likelihood that government incentives will be withdrawn on 1st January 2016, so this is not currently a recommendation. If government incentives remain favourable, then this recommendation could be revisited. Compiled by Orchard Ltd Page 9 of 15

10 5 Background to Recommendations To produce this survey, firstly a walk-round was organised with Sandy Reid, who is the Links Superintendent, and has taken on the responsible for the energy systems and the building upkeep. This gave the author a chance to see the energy systems and how they were being used. In addition to a number of minor items, we found a total of four short-term opportunities and a number of minor ones. Having discussed the recommendations, we looked at what would be involved in making them happen and the potential pitfalls. Firstly the opportunities were listed as on page 4 above: Understand how the various heating systems interact with one another at the Golf Centre Propose energy saving measures in the Golf Centre and the Greenkeepers Complex. Much of these will be behavioural. Investigate why there have been reports of lack of hot water at some busy times. Propose an illustration of alternative biomass and gas conversions for the Greenkeepers Complex Secondly, costs had to be estimated for each opportunity, then a check for compatibility with available funding alternatives. These are: Renewable Heat Incentive (RHI). This is available to organisations which install qualifying renewable heating plant. It takes the form of a quarterly payment over a period of twenty years. The payments are based on metered heat. Typically, a biomass heating project will payback in six to eight years, the savings coming from both the RHI and the reduction in fuel cost. Regional Loan Schemes. These loan funds are available to SMEs that are able to offer benefits to their local economy through employment opportunities, wealth and growth. Go to for more information. Low Carbon Skills Fund. This fund is designed specifically for staff training to exploit the low-carbon economy. It provides 50% of training costs in areas like renewable and low-carbon energy, energy efficiency, clean technologies, waste reduction and carbon reduction. This support may be particularly applicable to Second Opportunities, as it would help to fund energy awareness training for staff. Go to for more information Enhanced Capital Allowance. This scheme allows businesses to claim 100% first year capital allowance on investments in certain energy and water saving equipment against taxable profits of the period of investment. Compiled by Orchard Ltd Page 10 of 15

11 6 Savings Opportunities Understanding the heating systems The heating and ventilation (HVAC) systems are integrated through a Building Energy Management system (BEMS) in the boilerhouse. It is understood that in the period since initial commissioning, the settings have either drifted or have been reset. Without a clear picture of how this control operates, it will not give the required internal environment in the building. In addition, there is the risk that some of the energy components may actually be using more energy as a result of conflicts between settings. It is strongly recommended that the entire HVAC plant is recommissioned to return it to its handover configuration. When this is complete, at least two permanent, on-site members of Pro Centre staff are trained in its use. It is important that this capability is retained in-house. A retired member of the original design team has been identified as still living locally and it is recommended that he is engaged to carry out the above. Costs, Benefits and Finance The benefit is a reduced energy bill. On-site staff should be responsible for making the day-to-day changes to the BEMS to suit the varying conditions of season, occupancy and events which a facility like this will experience. It is likely that this result in energy savings of at least 15%, which would result in a saving of around 3,750 per year. Risks and Solution Alternatives There are no obvious risks. Conclusions It is essential that the systems are returned to their handover condition. This may highlight other issues, but until it is done, there is no way of identifying these. Compiled by Orchard Ltd Page 11 of 15

12 Photograph of the gas boilers Assessment of recommendations from the report of 2012 Many of the recommendations from the previous energy audit report of 2012 are still valid. These were:- 1) Energy policy 2) Management practice 3) Staff awareness 4) Data management 5) Pro Centre issues 6) Greenkeeping complex issues Items 1-4 are closely related and similar issues will be solved simultaneously. An energy policy will see the creation of an Energy Manager function. This is not a full-time task, but will see responsibility for energy issues within CGLMC managed by one single contact person. It is also closely related to Item 1 above. The benefit is a reduced energy bill. Experience in similar situations shows that such an appointment can result in savings of between 10 and 15%. In this case, some of those savings will already appear by having an understanding of HVAC systems, so the incremental increase in savings is likely to be less than 10% of the energy used by CGLMC across all sites (except the course machinery). This would result in savings of around 3,500 per year. Item 5 Pro Centre issues. Spikes in electrical consumption were investigated and found to be caused by the three 30kW irrigation pumps at South America. This is not related to the Pro Centre. Base electrical load of 5kW was stated by the previous report. A logging exercise should be carried out to see what is running, as it is likely to be unnecessary during out of hours. If half of that power can be switched off, then there is a potential saving of 20,000kWh can be made. This would be worth 2,570 per year. Compiled by Orchard Ltd Page 12 of 15

13 Heat pump/boiler operation. This is part of item 1 above, Understanding the heating systems and is not additional to that saving. Item 6 Greenkeeping complex issues. Base electrical load here appears to be even higher at 7kW. Identifying and switching off even half of that will save around 30,000kWh per year, a saving 3,860. It is recommended that a logging exercise is undertaken on each of the sub-circuits in the complex to identify where this energy is going. The heating in the greenkeeping shed is already only on at relevant times and adjusted accordingly throughout the year in conjunction with outside temperatures and with adjustment to working hours which vary from very early starts and finishes in the summer to later through the winter. Deliveries of oil to the complex have been sub-divided over the last two years to show what is for heating and what is for machinery. However the deliveries were made when the tank levels were down and not on a monthly or annual basis, so they are not an exact record. As an illustration, if 10% of the overall annual oil bill is saved, then that would amount to around 670. It is recommended that deliveries of oil for heating and for machinery are recorded separately, so that heating energy can be identified. Fitting timers on drinks machines will save around 200 per year. Investigate reports of lack of hot water in the showers We were told of reports that there were occasions when the hot water ran out. To investigate this, a set of button loggers were fitted for a month to the flow and return legs of the hot water circulation pipework. Through this period, routine Legionella procedures were also carried out repeatedly by flowing through all showers simultaneously. The result was inconclusive, as the temperature remained steady at around o C. The recommendation now is to contact the Links Superintendent immediate this issue recurs and identify the factors in play at the time. Automatic lighting controls in Pro Centre There are two areas in the Pro Centre where PIRs could beneficially be installed to switch off lighting either when available lighting is sufficient or where there are periods of low occupancy. These are the reception area under the atrium (good available light) and the locker rooms (routine periods of low occupancy). Assuming these lights are normally on 12 hours per day for most of the year, then the saving by fitting PIRs in these areas would be around 1,600kWh per year, or 200. The cost of installation (assuming no recabling is required) would be about the same, giving a one-year payback. Illustration of alternative heating systems for the Greenkeeping Complex There is an existing oil-fired boiler of 92kW capacity and a workshop fan convector of 117kW capacity, which is also oil-fired. Due to the cost of oil, CGLMC expressed interest in alternative systems. Both gas and biomass are Compiled by Orchard Ltd Page 13 of 15

14 considered here. It is recommended that the replacement is large enough to heat both the offices and the workshop, a load of over 200kW. Alternative 1 gas conversion Unfortunately, as mentioned above, the oil consumption is unknown for the two heating units, so a figure had to be estimated. This meant that we were unable to obtain an installation cost for a gas supply to the Complex, as contractors will not quote without knowing the previous year s consumption. A figure of 25,000 is therefore proposed. In addition, there will be on-site pipe and a meter kiosk, a further 3,000. A figure of 2,500 is estimated for a replacement boiler burner and to replace the workshop heater with a gas-fired standalone heater, including pipework and installation would probably come to around 5,000. This gives a project total of around 35,500. For an illustrative annual load of 200,000kWh, the annual fuel saving by going to gas is likely to be around ( )/100 x 200,000 = 4,500, a payback of 7.9 years. Alternative 2 biomass conversion Illustration based on oil consumption of 200,000kWh, oil at 5.5p/kWh (65p/ltr) and biomass at 3.1p/kWh for woodchip. Existing Costs = 200,000kWh x 5.5p/kWh = 11,000 Proposed Load (biomass) = (200,000 x 0.7/ 0.9) = 155,000kWh (due to increased combustion efficiency. Proposed Cost (biomass) = 155,000kWh x 3.1 p/kwh = 4,805 Fuel Cost Saving = 11,000-4,805 = 6,195 *RHI (Tier1) = 155,000 x 5.18p/kWh = 8,029 Total Annual Saving = Annual Fuel Cost Saving + Annual RHI Total Annual Saving: 6, ,029 = 14,220 Capex for boiler and auxiliaries only, estimated at 125,000. Payback: cap ex /annual saving = 125,000/14,220 = 8.8 years *The government will support this with Renewable Heat Incentive (RHI), paid at 5.18p/kWh for the first 1,314 kwh for twenty years. Important note. Both of the above should be treated as illustrations only and any future decisions should be based on contractor s quotations, which will require an accurate measurement of fuel actually consumed by the buildings at the complex for a year. Compiled by Orchard Ltd Page 14 of 15

15 Compiled by Orchard Ltd Page 15 of 15

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 6 PIPERSQUOY TERRACE, KIRKWALL, KW15 1EL Dwelling type: Mid-terrace bungalow Date of assessment: 21 November 2017 Date

More information

Energy Performance Certificate (EPC)

Energy Performance Certificate (EPC) Energy Performance Certificate (EPC) SMITHY COTTAGE, SCOTTISH BORDERS, KELSO, TD5 8LZ Dwelling type: Detached house Date of assessment: 08 May 2014 Date of certificate: 22 May 2014 Total floor area: 103

More information

Renewables Update Argyll, Nov John Farquhar Senior Renewables Consultant

Renewables Update Argyll, Nov John Farquhar Senior Renewables Consultant Renewables Update Argyll, Nov 2017 John Farquhar Senior Renewables Consultant Renewables today Over the last year there have been reductions in the renewables financial incentives for both electricity

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 29 HORDALAND, KIRKWALL, KW15 1UN Dwelling type: End-terrace bungalow Date of assessment: 10 January 2018 Date of certificate:

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 14 HIGH STREET, KIRKWALL, KW15 1AZ Dwelling type: Mid-terrace house Date of assessment: 05 June 2017 Date of certificate:

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 12 STATION SQUARE, ST MARYS, ORKNEY, KW17 2SE Dwelling type: Semi-detached bungalow Date of assessment: 08 August 2017

More information

Elmwood Golf Course Solar PV Initial Feasibility Study

Elmwood Golf Course Solar PV Initial Feasibility Study Elmwood Golf Course Solar PV Prepared by: SAC Consulting Contact: Email: Fiona Salter fiona.salter@sac.co.uk Phone: 0131 603 7513 Date: 27 th August 2015 1 Contents 1 Contents... 1 2 Introduction... 1

More information

Energy Performance Certificate (EPC)

Energy Performance Certificate (EPC) Energy Performance Certificate (EPC) You can use this document to: FLAT 16, 11 RUSSELL GARDENS, EDINBURGH, EH12 5PG Dwelling type: Top-floor flat Date of assessment: 08 August 2014 Date of certificate:

More information

Project Highlights. Case Study Biomass Boiler Installation at Lochaber Leisure Centre, Fort William. Introduction

Project Highlights. Case Study Biomass Boiler Installation at Lochaber Leisure Centre, Fort William. Introduction Case Study Biomass Boiler Installation at Lochaber Leisure Centre, Fort William Project Highlights A 400kW wood pellet biomass boiler and 9,000 litre thermal store installed at Lochaber Leisure Centre,

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 5 ST SUNNIVA STREET, LERWICK, SHETLAND, ZE1 0HL Dwelling type: End-terrace house Date of assessment: 26 July 2017 Date

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 4 MARKET GREEN, DOUNBY, ORKNEY, KW17 2HU Dwelling type: Semi-detached house Date of assessment: 05 April 2018 Date

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 10 INNIS PLACE, KINLOCHBERVIE, LAIRG, IV27 4RW Dwelling type: Semi-detached house Date of assessment: 24 March 2016

More information

Energy Performance Certificate (EPC)

Energy Performance Certificate (EPC) Energy Performance Certificate (EPC) You can use this document to: 13H CATTERMILLS, CROFTAMIE, GLASGOW, G63 0BB Dwelling type: Top-floor flat Date of assessment: 28 November 2014 Date of certificate: 01

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland KLONDYKE, ST OLA, KIRKWALL, KW15 1SX Dwelling type: Detached house Date of assessment: 19 January 2018 Date of certificate:

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 31 ARTILLERY PARK, HADDINGTON, EH41 3PZ Dwelling type: Semi-detached bungalow Date of assessment: 18 September 2017

More information

Top Energy Savers: game

Top Energy Savers: game Top Energy Savers: game Playing with the cards The idea of the Top Energy Savers game is to show how the various Green Deal energy saving and generating measures perform in different types of households.

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 2, 7 NEW ORCHARDFIELD, EDINBURGH, EH6 5ES Dwelling type: Ground-floor flat Date of assessment: 10 November 2017

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 83 CARRICK KNOWE AVENUE, EDINBURGH, EH12 7DE Dwelling type: Top-floor flat Date of assessment: 06 December 2017 Date

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 1F1, 41 MARCHMONT CRESCENT, EDINBURGH, EH9 1HF Dwelling type: Mid-floor flat Date of assessment: 26 June 2015 Date

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 47 ELMWOOD AVENUE, INVERNESS, IV2 6HE Dwelling type: Detached house Date of assessment: 29 January 2018 Date of certificate:

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 0/1, 7 DUDLEY DRIVE, GLASGOW, G12 9SE Dwelling type: Ground-floor flat Date of assessment: 07 November 2016 Date

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 0/1, 27 COVENTRY DRIVE, GLASGOW, G31 3JG Dwelling type: Ground-floor flat Date of assessment: 10 September 2015

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland NARRA, 2 WHITECREST PARK, TANKERNESS, ORKNEY, KW17 2QR Dwelling type: Semi-detached bungalow Date of assessment: 16

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland BROCKWOODLEES, CANONBIE, DG14 0XD Dwelling type: Detached house Date of assessment: 20 August 2015 Date of certificate:

More information

Solar hot water systems in new housing

Solar hot water systems in new housing GENERAL INFORMATION REPORT 88 Solar hot water systems in new housing a monitoring report GENERAL INFORMATION REPORT 88 BEST PRACTICE PROGRAMME INTRODUCTION This Report describes the monitoring of eight

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 1, 5 O'CONNELL STREET, HAWICK, TD9 9HT Dwelling type: Ground-floor flat Date of assessment: 10 October 2014 Date

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland VIERA VIEW, HAMMAR ROAD, RENDALL, ORKNEY, KW17 2HF Dwelling type: Detached bungalow Date of assessment: 26 September

More information

Industrial Energy Saving Solutions. Barry Paschali

Industrial Energy Saving Solutions. Barry Paschali Industrial Energy Saving Solutions Learn how your business can save money through efficient use of compressed air, efficient use of motors & drives, heat recovery, more efficient lighting, voltage optimisation

More information

SOUTH LANARKSHIRE COLLEGE LOW CARBON TEACHING BUILDING TECHNICAL CASE STUDY

SOUTH LANARKSHIRE COLLEGE LOW CARBON TEACHING BUILDING TECHNICAL CASE STUDY SOUTH LANARKSHIRE COLLEGE LOW CARBON TEACHING BUILDING TECHNICAL CASE STUDY PROJECT INTRODUCTION For this project our brief from South Lanarkshire College was a very simple one to design a new eight classroom

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 2 COURTHILL FARM COTTAGES, KELSO, TD5 7RU Dwelling type: Semi-detached house Date of assessment: 02 March 2017 Date

More information

Energy Performance Certificate (EPC)

Energy Performance Certificate (EPC) Energy Performance Certificate (EPC) GF HATSTON APARTMENT, HATSTON PARK, ST OLA, KIRKWALL, KW15 1TZ Dwelling type: Ground-floor flat Date of assessment: 23 January 2015 Date of certificate: 30 January

More information

Mount Gambier Aquatic Centre Biomass Boiler

Mount Gambier Aquatic Centre Biomass Boiler Case Study Mount Gambier Aquatic Centre Biomass Boiler April 2014 Background The Mount Gambier Aquatic Centre was constructed by the Mount Gambier City Council in the 1980s as an outdoor pool facility

More information

Renewable Energy the opportunities?

Renewable Energy the opportunities? Renewable Energy the opportunities? The main incentive for new and young entrants is a profitable business which provides good opportunities for business growth. Whilst there has been interest in, and

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Brook House Dwelling type: Detached house Claverley Date of assessment: 01 August 011 WOLVERHAMPTON Date of certificate: 01 August 011 WV5 7AU Reference number: 8107-9998-689-3606-0893

More information

The Renewable Heat Incentive

The Renewable Heat Incentive The Renewable Heat Incentive Heating RHI Expected Outcome Non-Domestic Ground Source Heat Pumps Air Source and Ground Source Heat Pumps Increased tariffs for Air and Ground Source RHI First Announcement

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland FLAT 1/1 8 HARTFIELD GARDENS, CROSSLET ROAD, DUMBARTON, G82 2DE Dwelling type: Mid-floor flat Date of assessment: 15

More information

Sustainable Business Breakfast

Sustainable Business Breakfast Sustainable Business Breakfast Wiston House, 9 th February 2017 Event supported by the European Regional Development Fund What s coming up? 08:20 Welcome Rowan Wallis, Sustainable Business Network 08:25

More information

Complying with the Minimum Energy Efficiency Standards (MEES)

Complying with the Minimum Energy Efficiency Standards (MEES) Complying with the Minimum Energy Efficiency Standards (MEES) Advantages of using DSM software to calculate the EPC Rating Introduction The Minimum Energy Efficiency Standards (MEES) for commercially rented

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland St Sunniva Skete, Fetlar, Shetland, ZE2 9DJ Dwelling type: Detached bungalow Date of assessment: 23 May 2017 Date of

More information

E F G. Recommendations for the cost-effective improvement of energy performance

E F G. Recommendations for the cost-effective improvement of energy performance Energy Performance Certificate Non-Domestic buildings and buildings other than dwellings UNITS 3-4 CREST BUSINESS CENTRE, 2 GLEN TYE ROAD, STIRLING FK7 7LH Date of assessment: 15 January 2016 Date of certificate:

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland Grytingr, Upper Baila, Lerwick, Shetland, ZE1 0SF Dwelling type: Detached house Date of assessment: 09 August 2016

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate Decleigh Mill Lane BRIGG DN20 8NA Dwelling type: Detached house Date of assessment: 22 August 2011 Date of certificate: 22 August 2011 Reference number: 2228-0096-6268-8899-4900

More information

Energy Performance Certificate (EPC)

Energy Performance Certificate (EPC) Energy Performance Certificate (EPC) You can use this document to: 1F1, 17 BRYSON ROAD, EDINBURGH, EH11 1ED Dwelling type: Mid-floor flat Date of assessment: 21 October 2013 Date of certificate: 24 October

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 129, North Road St. Andrews BRISTOL BS6 5AH Dwelling type: Mid-terrace house Date of assessment: 7 January 2009 Date of certificate: 7 January 2009 Reference number: 8281-6129-5770-1683-9006

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 218, Lode Lane SOLIHULL B91 2HS Dwelling type: Semi-detached house Date of assessment: 9 October 2008 Date of certificate: 12 October 2008 Reference number: 8078-6120-5059-2221-7002

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate Penrhiwpinne Dwelling type: Detached house Capel Dewi Date of assessment: 25 March 2010 LLANDYSUL Date of certificate: 26 March 2010 SA44 4PG Reference number: 0971-2845-6572-9120-0165

More information

Top actions you can take to save money and make your home more efficient

Top actions you can take to save money and make your home more efficient You can use this document to: Energy Performance Certificate (EPC) Dwellings Scotland 38A WADE'S CIRCLE, INVERNESS, IV2 5JG Dwelling type: Ground-floor flat Date of assessment: 01 February 2018 Date of

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 1096 Manchester Road ROCHDALE Lancashire OL11 2XJ Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: End-terrace house 02 October

More information

3.0 University Energy Management Questionnaire

3.0 University Energy Management Questionnaire 3.0 University Energy Management Questionnaire 3.1 INTRODUCTION To supplement the individual case studies, a postal survey was undertaken of energy management in UK universities. The survey was based very

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 168, Hanging Lane BIRMINGHAM B31 5DN Dwelling type: Semi-detached house Date of assessment: 1 February 009 Date of certificate: February 009 Reference number: 898-4010-65-5981-04

More information

Total floor area: 41 m 2 Main type of heating and fuel: Room heaters, electric

Total floor area: 41 m 2 Main type of heating and fuel: Room heaters, electric Energy Performance Certificate Address of dwelling and other details 1/2 67 CHURCH STREET DUNDEE DD3 7HP This dwelling's performance ratings Dwelling type: Mid-floor flat Name of approved organisation:

More information

Energy Performance Certificate

Energy Performance Certificate 6, Grafton Road, Brigstock, KETTERING, NN14 3EY Dwelling type: Semi-detached house Reference number: 2638-4081-7286-4856-7984 Date of assessment: 27 June 2016 Type of assessment: RdSAP, existing dwelling

More information

Gasification Power / Heat & Power Pure Heat. Pure power generation only up to 40% efficient.

Gasification Power / Heat & Power Pure Heat. Pure power generation only up to 40% efficient. 1.1. Uses of Biomass for Energy Gasification Power / Heat & Power Pure Heat Gasification is a process that converts organic materials into combustible gases, which can be cleaned and burnt or expanded

More information

Energy Performance Certificate

Energy Performance Certificate 31, Strathmore Crescent, Wombourne, WOLVERHAMPTON, WV5 9AY Dwelling type: Semi-detached bungalow Reference number: 8004-8838-3529-0296-9643 Date of assessment: 17 June 2014 Type of assessment: RdSAP, existing

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate The Grain House, Dwelling type: Detached house Linley Green, Date of assessment: 07 May 2008 Whitbourne, Date of certificate: 07 May 2008 WORCESTER, WR6 5RQ Reference number:

More information

Hybrid heating. system. Heat pump. combi boiler. Smart logic

Hybrid heating. system. Heat pump. combi boiler. Smart logic Hybrid heating system Gas combi boiler Heat pump Smart logic Daikin Altherma Hybrid heating system A hybrid gas boiler solution for efficient heating & hot water Daikin Altherma Hybrid system is the ideal

More information

How heat pumps can help your project to pass Planning and Building Regulations Learning Outcomes Understand current planning and building regulations Understand the software used to meet these regulations

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Estimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Estimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home Energy Performance Certificate Flat 3a 49 Norwood Road Stretford MANCHESTER M3 8PN England & Wales EU Directive 00/91/EC Dwelling type: Top-floor flat Date of assessment: 1 July 011 Date of certificate:

More information

Guidance Note for CLA members

Guidance Note for CLA members Guidance Note for CLA members Feed in Tariff (FIT) for Solar Photovoltaic (PV) Installations Date: 10 February 2015 CLA Guidance Note Reference: GN11-15 Introduction The Feed in Tariff (FiT) scheme was

More information

Introduction to wood fuel and the RHI. Heartwoods West Midlands Wood Fuel Project

Introduction to wood fuel and the RHI. Heartwoods West Midlands Wood Fuel Project Introduction to wood fuel and the RHI Heartwoods West Midlands Wood Fuel Project Overview Why woodfuel? How woodfuel is currently used Renewable Heat Incentive Why Woodfuel? Carbon lean, 95% CO2 saving

More information

Asset Energy Calculator Guidance

Asset Energy Calculator Guidance Asset Energy Calculator Guidance Introduction This section has been produced to give BREEAM In-Use assessors further guidance on the workings of the asset energy calculator so it is clear how any improvements

More information

Program Guide. NB Power Commercial Buildings Retrofit Program. Version 5.5 August 2016

Program Guide. NB Power Commercial Buildings Retrofit Program.  Version 5.5 August 2016 NB Power Commercial Buildings Retrofit Program Version 5.5 August 2016 www.nbpower.com TABLE OF CONTENTS 1.0 PROGRAM INTRODUCTION... 1 2.0 ELIGIBILITY AND REQUIREMENTS... 1 2.1 ELIGIBLE BUILDING TYPES...

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 16, Pendre Crescent Dwelling type: Semi-detached house Llanharan Date of assessment: 23 March 2012 PONTYCLUN Date of certificate: 23 March 2012 CF72 9PP Reference number:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 147, Warren Hill Road, BIRMINGHAM, B44 8ES Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Semidetached house

More information

Energy Savings at Military Installations: A Case Study

Energy Savings at Military Installations: A Case Study Energy Savings at Military Installations: A Case Study *Stavropoulos, G.G 1 1, 2, 3 and Skodras, G. 1 Lab of Chemical Process Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece 2 Laboratory

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Drop Anchor Cottage, Churchtown Mullion Helston Cornwall TR12 7HQ Dwelling type: Mid-terrace house Date of assessment: 31 August 2010 Date of certificate: 02 September 2010

More information

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company. Report To: Mr. John Smith Smith Printing Company ENERGY AUDIT 123 Main Street Mississauga, Ontario January 1, 2009 120 Carlton Street, Suite 212 Toronto, Ontario M5A 4K2 Tel 416-964-3246 Toll Free 1-866-964-3246

More information

BUILDING ENERGY EFFICIENCY CERTIFICATE

BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING DETAILS Building name 390 St Kilda Road Certificate no. Owner's name Building address The Trust Company (Australia) Limited 390 St Kilda Road, Melbourne,

More information

BUILDING ENERGY EFFICIENCY CERTIFICATE

BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING ENERGY EFFICIENCY CERTIFICATE BUILDING DETAILS Building name BEEC Example Building Certificate no. Owner's name Example Company Name Issue date 6/10/2011 Building address 123 ANYWHERE STREET BRISBANE

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 48, Sandbeds Road Dwelling type: Mid-terrace house HALIFAX Date of assessment: 4 May 010 HX 0QL Date of certificate: 4 May 010 Reference number: 8950-65-760-9664-996 Type

More information

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 57, Watling Gardens Dwelling type: Mid-floor flat DUNSTABLE Date of assessment: 04 July 2011 LU6 3FD Date of certificate: 05 July 2011 Reference number: 0348-2008-6213-8589-1970

More information

Energy Efficiency Rating

Energy Efficiency Rating Energy Performance Certificate Northern Ireland 33, Kitcheners Avenue LARNE BT40 2AB Date of assessment: 28 March 2017 Date of certificate: 28 March 2017 Reference number: 2289-8055-0207-6793-9944 Type

More information

Related party disclosure: Technical Information Benchmark. 82 m² 249 kwh/m² per year 53 kg/m² per year

Related party disclosure: Technical Information Benchmark. 82 m² 249 kwh/m² per year 53 kg/m² per year Energy Performance Certificate Northern Ireland 13 Oaktree Drive ANTRIM BT41 1DA Date of assessment: Date of certificate: Reference number: Accreditation scheme: Assessor's name: Assessor's accreditation

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 18, Coleridge Road Maltby ROTHERHAM S66 7LT Dwelling type: Mid-terrace house Date of assessment: 20 January 2012 Date of certificate: 01 February 2012 Reference number: 0598-2026-6252-9452-2960

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 51, Kingfisher Close Dwelling type: Mid-terrace house FARNBOROUGH Date of assessment: 8 January 011 GU14 9QX Date of certificate: 31 January 011 Reference number: 879-639-8760-388-596

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 8, Stanhome Drive West Bridgford NOTTINGHAM NG2 7FF Dwelling type: Detached house Date of assessment: 2 July 2009 Date of certificate: 3 July 2009 Reference number: 0565-2842-6835-0301-1751

More information

YHA Hadrian s Wall at The Sill England & Wales

YHA Hadrian s Wall at The Sill England & Wales England & Wales SUMMARY Project description: The Sill (UK s first dedicated landscape discovery centre) will attract more than 100,000 visitors each year to the all-weather, year-round facility that will

More information

Energy demand analysis for small and medium scale heat users in Rotorua aiming at converting existing heating systems to bioenergy.

Energy demand analysis for small and medium scale heat users in Rotorua aiming at converting existing heating systems to bioenergy. Energy demand analysis for small and medium scale heat users in Rotorua aiming at converting existing heating systems to bioenergy. Dr Nielsen, Per, Mr. G. Estcourt, Mr M. Shepherd Forest Research, Sala

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20)

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Energy Performance Certificate 12, Andrew Close HALIFAX HX3 9RT Dwelling type: Mid-terrace house Date of assessment: 29 November 2011 Date of certificate: 29 November 2011 Reference number: 8190-0719-7329-6126-5993

More information

HGCA Borders Monitor Farm Alistair Hodge Whitsome East Newton. Using Biomass to Dry Grain & Renewable Heat Incentive

HGCA Borders Monitor Farm Alistair Hodge Whitsome East Newton. Using Biomass to Dry Grain & Renewable Heat Incentive HGCA Borders Monitor Farm Alistair Hodge Whitsome East Newton Report on 6th Meeting held on 17 th January 2012 Using Biomass to Dry Grain & Renewable Heat Incentive FUTURE EVENTS The next Monitor Farm

More information

Application of Advanced Energy Technologies

Application of Advanced Energy Technologies GLOBALCON 2002 Philadelphia, Pennsylvania March 27, 2002 Application of Advanced Energy Technologies Michael K. West, Ph.D., P.E. Building Systems Scientist Advantek Consulting, Inc. www.advantekinc.com

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Daneve, Cold Blow, NARBERTH, SA67 8RN Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Detached bungalow 05742839627592007765

More information

Renewable Heat Incentive: proposals for a domestic scheme. Community Housing Cymru Group response

Renewable Heat Incentive: proposals for a domestic scheme. Community Housing Cymru Group response Renewable Heat Incentive: proposals for a domestic scheme Community Housing Cymru Group response 1. About Us The Community Housing Cymru Group (CHC Group) is the representative body for housing associations

More information

Renewable Energy - A technology overview and the new Feed in Tariffs. Jos Mister Energy Saving Trust

Renewable Energy - A technology overview and the new Feed in Tariffs. Jos Mister Energy Saving Trust Renewable Energy - A technology overview and the new Feed in Tariffs Jos Mister Energy Saving Trust Overview Renewable Technology Overview Generating electricity Generating heat Feed in Tariffs Clean Energy

More information

Renewable Heat Incentive (RHI) Opportunities for Social Landlords in the RHI

Renewable Heat Incentive (RHI) Opportunities for Social Landlords in the RHI (RHI) Opportunities for Social Landlords in the RHI [Name] [Date] Three good reasons to choose renewable heat 1. Now every building will be able to get an incentive if it goes renewable the RHI is a reality

More information

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Estimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home

(92 plus) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Estimated energy use, carbon dioxide (CO ) emissions and fuel costs of this home Energy Performance Certificate Horn Tavern Colway Lane LYME REGIS DT7 3AR England & Wales EU Directive 00/91/EC Dwelling type: Detached house Date of assessment: 01 July 011 Date of certificate: 03 July

More information

Building Better Buildings BPE Case Study Dungannon Passivhaus

Building Better Buildings BPE Case Study Dungannon Passivhaus Building Better Buildings BPE Case Study Dungannon Passivhaus Choice Housing Ireland Ltd Lisnahull Terrace, Dungannon Building Performance Evaluation The Performance Gap Lessons for industry Choice Housing

More information

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA C. Şerban 1, E. Eftimie 1 and L. Coste 1 1 Department of Renewable Energy Systems and Recycling Transilvania University of Braşov B-dul

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Northern Ireland 19, Letterloan Road, Macosquin, COLERAINE, BT51 4PP Date of assessment: Date of certificate: Reference number: Accreditation scheme: Assessor s name: Assessor

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 3, Raynham Avenue, LONDON, N18 2BN Dwelling type: Midterrace house Date of assessment: Date of certificate: Reference number: 08632873661105910635 Total floor area: 92 m²

More information

Solar for Homeowners. Discover solar technologies for your home

Solar for Homeowners. Discover solar technologies for your home Solar for Homeowners Discover solar technologies for your home What We Do Information Resource & Expert Implementation Partner Energy Programs Technical Assistance Training & Education Areas of Expertise

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Northern Ireland 35, Hightown Road NEWTOWNABBEY BT36 7TZ Energy Efficiency Rating Date of assessment: 05 December 009 Date of certificate: 05 December 009 Type of assessment:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 3, Jasper Close, CARDIFF, CF5 2RX Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Topfloor flat 03 December

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Orchard Way Dwelling type: Detached house Great Moor Road Date of assessment: 13 October 011 Pattingham Date of certificate: 13 October 011 WOLVERHAMPTON Reference number:

More information

New Jersey Board of Public Utilities Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings

New Jersey Board of Public Utilities Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings New Jersey Board of Public Utilities Clean Energy Program Opportunities for Commercial, Industrial and Institutional Buildings Gary E Finger Ombudsman June 2013 NJ Clean Energy Program Background Introduced

More information

DTE Energy Commercial & Industrial Energy Optimization Program. Trade Ally Meeting. Guardian Plumbing & Heating January 20, 2011

DTE Energy Commercial & Industrial Energy Optimization Program. Trade Ally Meeting. Guardian Plumbing & Heating January 20, 2011 DTE Energy Commercial & Industrial Energy Optimization Program Trade Ally Meeting Guardian Plumbing & Heating January 20, 2011 Agenda Introduction DTE Energy Your Energy Savings Program Overview 2011 Program

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Little Barn Marley Heights HASLEMERE GU27 3LU Dwelling type: Detached house Date of assessment: 9 March 2009 Date of certificate: 10 March 2009 Reference number: 8591-6927-5100-0861-1006

More information

Energy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC

Energy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC Energy Efficiency Solutions for Multifamily Housing Clark Energy Group LLC 1 Agenda About Clark Energy Group Energy Service Company (ESCO) Overview ESCO Services Utility Rate Forecasts Making the Decision

More information

Biomass boilers and room heaters

Biomass boilers and room heaters Technology information leaflet ECA757 Biomass boilers and room heaters A guide to equipment eligible for Enhanced Capital Allowances Contents Introduction 01 Background 01 Setting the scene 01 Benefits

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 29 Netherstone Grove SUTTON COLDFIELD West Midlands B74 4DT Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Detached house 01

More information