Food Service Technology Center
|
|
- Paula Harper
- 6 years ago
- Views:
Transcription
1 Food Service Technology Center Lainox NAGB072 Gas Combination Oven Test Report FSTC Report # R0 Application of ASTM Standard Test Method F February 2018 Prepared by: Rodney Davis Frontier Energy Contributors: Edward Ruan Wes Andrews Frontier Energy Prepared for: Pacific Gas and Electric Company Customer Energy Efficiency Programs PO Box San Francisco, California Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. 2018
2 Food Service Technology Center Background The information in this report is based on data generated at the Pacific Gas and Electric Company (PG&E) Food Service Technology Center (FSTC). Dedicated to the advancement of the foodservice industry, The FSTC has focused on the development of standard test methods for commercial foodservice equipment since The primary component of the FSTC is a 10,000 square-foot laboratory equipped with energy monitoring and data acquisition hardware, 60 linear feet of canopy exhaust hoods integrated with utility distribution systems, equipment setup and storage areas, and a state-of-the-art demonstration and training facility. The FSTC Energy Efficiency for Foodservice Program is funded by California utility customers and administered by PG&E under the auspices of the California Public Utilities Commission (CPUC). California customers are not obligated to purchase any additional services offered by the contractor. Policy on the Use of Food Service Technology Center Test Results and Other Related Information Frontier Energy and the FSTC do not endorse particular products or services from any specific manufacturer or service provider. The FSTC is strongly committed to testing foodservice equipment using the best available scientific techniques and instrumentation. The FSTC is neutral as to fuel and energy source. It does not, in any way, encourage or promote the use of any fuel or energy source nor does it endorse any of the equipment tested at the FSTC. FSTC test results are made available to the general public through technical research reports and publications and are protected under U.S. and international copyright laws. Disclaimer Copyright 2018 Pacific Gas and Electric Company Food Service Technology Center. All rights reserved. Reproduction or distribution of the whole or any part of the contents of this document without written permission of FSTC is prohibited. Results relate only to the item(s) tested. Neither, Frontier Energy, PG&E nor any of their employees, or the FSTC, make any warranty, expressed or implied, or assume any legal liability of responsibility for the accuracy, completeness, or usefulness of any data, information, method, product or process disclosed in this document, or represents that its use will not infringe any privately-owned rights, including but not limited to, patents, trademarks, or copyrights. Reference to specific products or manufacturers is not an endorsement of that product or manufacturer by Frontier Energy, the FSTC, or PG&E. In no event will Frontier Energy or PG&E be liable for any special, incidental, consequential, indirect, or similar damages, including but not limited to lost profits, lost market share, lost savings, lost data, increased cost of production, or any other damages arising out of the use of the data or the interpretation of the data presented in this report. Retention of this consulting firm by PG&E to develop this report does not constitute endorsement by PG&E for any work performed other than that specified in the scope of this project. Legal Notice This report was prepared as a result of work sponsored by the California Public Utilities Commission (CPUC). It does not necessarily represent the views of the CPUC, its employees, or the State of California. The CPUC, the State of California, its employees, contractors, and subcontractors make no warranty, express or implied, and assume no legal liability for the information in this report; nor does any party represent that the use of this information will not infringe upon privately owned rights. This report has not been approved or disapproved by the CPUC nor has the CPUC passed upon the accuracy or adequacy of the information in this report. Revision History Revision num. Date Description Author(s) 0 Feb 2018 Initial Release R. Davis Page 2 of 15
3 Contents Equipment Description. 4 Test Location 4 Ventilation. 4 Test Instrumentation Inventory.. 5 FSTC Test Report: Results.. 6 Additions, Deviations, and Exclusions 8 ENERGY STAR Qualification.. 10 Manufacturer Specifications Sheet Report Certification.. 15 Page Page 3 of 15
4 Equipment Description Test Work Order Number (TWO) Manufacturer Lanoix (Piper) Model NAGB072 Serial Number LA Generic Equipment Type Gas Combination Oven Rated Input 102,500 Btu/h Construction Stainless steel exterior and interior, double tempered glass doors, 316 stainless steel steam generator, cooking probe Controls Touch screen, programmable cooking, 5 fan speeds, temperature control of product using probe, USB connection to download HACCP data External Dimensions (W x D x H) 46.1" x 35.2" x 32.3" Custom Settings (if any) Initial testing performed in August Additional testing followed in January 2018 with updated oven control software. Internal Dimensions (W x D x H) 27.0" x 30.0" x 24.0" Pan Capacity 14 Full-size Steam Table Pans (12" x 20" x 2.5") or (12" x 20" x 2.5") Test Location All testing was performed under controlled conditions in the FSTC laboratory facilities at Alcosta Blvd., Suite 101, San Ramon, CA Ventilation FSTC researchers installed the equipment on a tiled floor under a four-foot-deep canopy hood, which operated at a nominal exhaust rate of 300 cfm per linear foot. The hood was mounted six feet, six inches above the floor, with at least six inches of clearance between the vertical plane of the equipment and the hood s edge. Page 4 of 15
5 Test Instrumentation Inventory Description (ID) Manufacturer Model Measurement Range Resolution Calibration Date Next Calibration DAQ Temp (ALA112) National Instruments FP-TC F 0.1 F 08/08/ /31/2018 DAQ Pulse (ALA112) National Instruments CTR ,000 pulses/s 1 pulse 08/08/ /31/2018 DAQ Temp (ALE515) National Instruments FP-TC F 0.1 F 08/09/ /31/2018 DAQ Pulse (ALE515) National Instruments CTR ,000 pulses/s 1 pulse 08/09/ /31/2018 Hot Well (ALZ909) Fluke 9100S F 0.1 C or F 03/21/ /28/2018 Cold Well (ALZ910) Fluke 9102S F 0.1 C or F 08/30/ /31/2018 Water Meter (ALD416) Seametrics SEB gpm gal 08/31/ /31/2018 Electric Meter (ALE511) Continental Controls WNB-3Y-208-P 0 20A 0.02 Wh 08/24/ /24/2018 Digital Scale (ALC304) Acculab SVI-20B 0 44lb lb 06/05/ /31/2018 Gas Meter (ALC306) Sensus R CFH 0.05 ft³ 08/15/ /31/2017** Gas Meter (ALC306) Sensus R CFH 0.05 ft³ 08/31/ /31/2018 Gas Press. (ALC307) Dwyer LPG3-D8142N 0 15 inwc 0.2 inwc 08/15/ /31/2017** Gas Press. (ALC307) Dwyer LPG3-D8142N 0 15 inwc 0.2 inwc 08/31/ /31/2018 Water Meter (ALE512) Seametrics SEB gpm gal 03/07/ /31/2017** Water Meter (ALE512) Seametrics SEB gpm gal 04/04/ /30/2018 Gas Meter (CKVLF617) Sensus R CFH 0.05 ft³ 08/16/ /31/2017** Gas Meter (CKVLF617) Sensus R CFH 0.05 ft³ 08/18/ /31/2018 Electric Meter (ALB209) Continental Controls WNB-3Y-208-P 0 20A 0.02 Wh 08/16/ /31/2017** Electric Meter (ALB209) Continental Controls WNB-3Y-208-P 0 20A 0.02 Wh 09/11/ /31/2018 Water Meter (ALC313) Seametrics SEB gpm gal 11/28/ /30/2017** Water Meter (ALC313) Seametrics SEB gpm gal 08/31/ /31/2018 **Instrumentation used in the August 2017 testing period of the NAGB072 with previous control software. Thermocouple Inventory Set Number Validation Date 143 (24-gauge, teflon) 01/16/ (30-gauge, fiberglass) 01/30/2018 Holding Equipment Inventory Description (ID) Manufacturer Model None Page 5 of 15
6 CMBO CRT FSTC Test Report: Results Purpose of Testing This testing determined the energy input rate, preheat time and energy, idle energy rate, heavy-load cooking efficiency and production capacity in convection and steam modes by applying the ASTM Standard Test Method F Cavity Volume Internal Oven-Cavity Volume (CuFt) Lainox NAGB072 Gas Combination Oven Energy Input Rate Rated Energy Input Rate (Btu/h) 102,500 Measured Energy Input Rate (Btu/h) 93,530 Difference (%) 8.8 Rated Electric Energy Rate (kw) 1.20 Preheat and Idle Steam Convection Preheat Ambient Temperature ( F) Final Preheat Temperature ( F) Duration (min) Gas Energy Consumption (Btu) 5,191 6,538 Electric Energy Consumption (kwh) Preheat Rate ( F/min) Water Consumption (gal) Idle Ambient Temperature ( F) Idle Energy Rate (Btu/h) 7,224 5,932 Electric Energy Rate (kw) Average Cavity Temperature ( F) Water Consumption Rate (gal/h) Nameplate Information: Heavy-Load Cooking Energy Efficiency Steam Convection Ambient Temperature ( F) Food Product Red Potatoes Russet Potatoes Cavity Temperature ( F) Cook Time (min) Water Consumption Rate (gal/h) Gas Cooking Energy Rate (Btu/h) 48,387 44,915 Electric Energy Rate (kw) Energy to Food (Btu/lb) Lainox Energy to Equipment (Btu/lb) Via Schiaparelli 15 Cooking-Energy Efficiency (%) 46.0 ± ± 4.3 Z.I. S. Giacomo di Veglia Production Capacity (lb/h) ± ± *Based on a minimum of three test replicates Page 6 of 15
7 CMBO CRT FSTC Test Report: Results Preheat and Idle - Combi Mode Preheat Ambient Temperature ( F) 75.0 Final Preheat Temperature ( F) 341 Duration (min) 8.63 Gas Energy Consumption (Btu) 8,310 Electric Energy Consumption (kwh) 0.05 Preheat Rate ( F/min) 30.9 Water Consumption (gal) <0.1 Idle Ambient Temperature ( F) 76.0 Idle Energy Rate (Btu/h) 12,884 Electric Energy Rate (kw) 0.31 Average Cavity Temperature ( F) 350 Water Consumption Rate (gal/h) 0.5 Steam Heavy-Load Red Potato (Perforated Deep Full-size Pans) Test Data Measured Values Test #1 Test #2 Test #3 Test Date 8/23/17 2/1/18 2/14/18 Ambient Temperature ( F) Number of Pans Total Potato Count Initial Weight of Potatoes (lb) Final Weight of Potatoes (lb) Initial Temperature of Potatoes ( F) Final Temperature of Potatoes ( F) Weight of Steam Table Pans (lb) Test Time (min) Test Voltage (V) Electric Energy Consumption (kwh) Gas Energy Consumption (Btu) 26,490 25,385 25,988 Gas Heating Value (Btu/scf) 1,048 1,033 1,035 Water Consumption (gal) Calculated Values Specific Heat of Potatoes (Btu/lb F) Sensible Energy (Btu) 12,147 11,554 11,721 Total Energy to Food (Btu) 12,147 11,554 11,721 Energy to Food (Btu/lb) Energy to Pans (Btu) Total Equipment Energy Consumption (Btu) 27,512 26,015 26,744 Energy to Equipment (Btu/lb) Results Cooking Energy Efficiency (%) Gas Cooking Energy Rate (Btu/h) 50,329 47,596 47,237 Electric Energy Rate (kw) Production Capacity (lb/h) Cook Time (min) Water Consumption Rate (gal/h) Page 7 of 15
8 CMBO CRT Convection Heavy-Load Cooking Russet Potato (Perforated Shallow Full-size pans) Test Data Measured Values Test #1 Test #2 Test #3 Test #4 Test Date 1/19/18 1/23/18 1/23/18 8/3/17 Ambient Temperature ( F) Number of Pans Total Potato Count Initial Weight of Potatoes (lb) Final Weight of Potatoes (lb) Initial Temperature of Potatoes ( F) Final Temperature of Potatoes ( F) Weight of Steam Table Pans (lb) Test Time (min) Test Voltage (V) Electric Energy Consumption (kwh) Gas Energy Consumption (Btu) 34,597 29,246 29,842 39,644 Gas Heating Value (Btu/scf) 1,035 1,028 1,028 1,032 Water Consumption (gal) Calculated Values Test #4 Specific Heat of Potatoes (Btu/lb F) Sensible Energy (Btu) 10,873 10,959 11,029 11,281 Latent Vaporization Energy (Btu) 8,099 6,125 6,300 9,773 Total Energy to Food (Btu) 18,973 17,083 17,329 21,053 Energy to Food (Btu/lb) Energy to Pans (Btu) Total Equipment Energy Consumption (Btu) 35,302 29,959 30,541 40,710 Energy to Equipment (Btu/lb) Results Test #4 Cooking Energy Efficiency (%) Gas Cooking Energy Rate (Btu/h) 45,293 40,247 42,610 51,508 Electric Energy Rate (kw) Production Capacity (lb/h) Cook Time (min) Water Consumption Rate (gal/h) Cooking Energy Efficiency Uncertainty Results Steam Convection Average (%) Standard Deviation Absolute Uncertainty (%) % Uncertainty Production Capacity Uncertainty Results Steam Convection Average (lb/h) Standard Deviation Absolute Uncertainty (lb/h) % Uncertainty Page 8 of 15
9 CMBO CRT Additions, Deviations, and Exclusions Additions: None Deviations: None Exclusions: The combination mode ice load cooking uniformity test, as specified in section 10.8 of ASTM F , was not performed. Page 9 of 15
10 ENERGY STAR Qualification FSTC testing of the Lanoix NAGB072 Gas Combination Oven resulted in an idle rate of 7,224 Btu/h in steam mode and 5,932 Btu/h in convection mode and an energy efficiency of 46.0% in steam mode and 56.1% in convection mode. The results comply with the ENERGY STAR Program Requirement for Commercial Ovens, Version 2.2 Page 10 of 15
11 Manufacturer Specifications Sheet Page 11 of 15
12 Manufacturer Specifications Sheet (Continued) Page 12 of 15
13 Manufacturer Specifications Sheet (Continued) Page 13 of 15
14 Manufacturer Specifications Sheet (Continued) Page 14 of 15
15 Page 15 of 15
Food Service Technology Center
Food Service Technology Center Nu-Vu X5 Electric Proofer/Convection Oven Test Report Application of ASTM Standard Test Method F1496-13 February 2015 Prepared by: Kong Sham Fisher-Nickel, Inc. Prepared
More informationFood Service Technology Center
Food Service Technology Center Henny Penny EEE143FFSX Electric Fryer Uninsulated Full and Split Vat Comparison Test Report Application of ASTM Standard Test Method F1361-07 (Reapproved 2013) July 2016
More informationSouthern California Gas Company Customer Programs Department
Appliance Test Report SCGAT110808A Imperial ICVG-1 prototype Full-Size Gas Convection Oven Performance Test Revision 0 Southern California Gas Company Customer Programs Department Issued Date: August 2011
More informationRapid Cook Oven Test Method Revision
Rapid Cook Oven Test Method Revision FSTC Report # 5011.09.01 February 2009 Prepared by: Greg Sorensen David Zabrowski Fisher-Nickel, Inc. Prepared for: Pacific Gas & Electric Company Customer Energy Efficiency
More informationBaker s Pride, Model 455GDCOGN1 Gas Full-Size Convection Oven Performance Test
Baker s Pride, Model 455GDCOGN1 Gas Full-Size Convection Oven Performance Test Application of ASTM Standard Test Method F 1496-99 SCGAT060530A Energy Resource Center Downey, CA July 2006 Prepared by: The
More informationLainox MG102T Gas Full-Size Combination Oven Performance Test
Lainox MG102T Gas Full-Size Combination Oven Performance Test Application of ASTM Standard Test Method F 1639-05 SCGAT070129A Energy Resource Center Downey, CA February 2006 Prepared by: The Gas Company
More informationRetherm Oven Performance Testing
Retherm Oven Performance Testing FSTC Report # 5011.03.26 August 2003 Prepared by: Todd Bell David Zabrowski Fisher-Nickel, Inc. Contributor: David Cowen Scott Miner Fisher-Nickel, Inc. 2003 by Fisher-Nickel,
More informationUltrafryer, Model PAR 3-14 Gas Fryer Performance Test
Ultrafryer, Model PAR 3-14 Gas Fryer Performance Test Application of ASTM Standard Test Method F 1361-95 FSTC Report 5011.99.78 Food Service Technology Center Manager: Don Fisher Final Report, September
More informationVulcan 14-inch Fryer Performance Testing
Vulcan 14-inch Fryer Performance Testing Application of ASTM Standard Test Method F 1361-99 FSTC Report 5011.00.87 Food Service Technology Center Final Report, December 2000 Prepared by: David Cowen David
More informationAGA Food Service Equipment, Model Infinity G2842 Gas Fryer Performance Tests
AGA Food Service Equipment, Model Infinity G2842 Gas Fryer Performance Tests Application of ASTM Standard Test Method F 1361-99 FSTC Report 5011.04.12 August, 2004 Prepared by: Todd Bell David Zabrowski
More informationFood Service Equipment Application - July 1, 2016 through June 30, 2017
Food Service Equipment Application - July 1, 2016 through June 30, 2017 Customer Information Company Name (as listed on utility bill) Doing usiness as (if applicable) Installation Start Date: Installation
More informationVulcan High Capacity Fryer Performance Testing
Vulcan High Capacity Fryer Performance Testing FSTC Report 5011.00.88 Food Service Technology Center Final Report, December 2000 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc. Contributors:
More informationCommercial Cooking Appliance Technology Assessment
Commercial Cooking Appliance Technology Assessment FSTC Report # 5011.02.26 2002 Prepared by: Don Fisher, Principle Investigator Contributors: Todd Bell Judy Nickel Charles Bohlig Greg Sorensen David Cowen
More informationPhilips Lumileds. 1. Applicable LUXEON Series part numbers 1. Philips Lumileds IESNA LM-80 Test Report Overview. Design Resource DR05
Philips Lumileds IESNA LM-80 Test Report Overview Design Resource DR05 Philips Lumileds IESNA LM-80 Test Report Overview This IESNA LM-80 Test Report complies with EPA ENERGY STAR document Program Guidance
More informationKeating Model 14 Incredible Frying Machine In-Kitchen Appliance Performance Report
Keating Model 14 Incredible Frying Machine In-Kitchen Appliance Performance Report FSTC Report 5011.98.56 Food Service Technology Center Manager: Don Fisher Final Report, December 1998 Prepared by: Bob
More informationCFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH
CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000
More informationMichigan Energy Code Training and Implementation Program
Michigan Energy Code Training and Implementation Program 1.0 Hour Advanced Program Course Number 16202 Residential Energy Plan Review School of Planning, Design & Construction Michigan State University
More informationresearch report Cold-Formed Steel Walls with Fiberboard Sheathing Shear Wall Testing RESEARCH REPORT RP REVISION 2006
research report Cold-Formed Steel Walls with Fiberboard Sheathing Shear Wall Testing RESEARCH REPORT RP05-3 2005 REVISION 2006 American Iron and Steel Institute Cold-Formed Steel Walls with Fiberboard
More informationTechnical Information
General Applications Process Applications Determining Heat Energy Lost The objective of any heating application is to raise or maintain the temperature of a solid, liquid or gas to or at a level suitable
More informationModel FDL 115 Safety drying chambers for limited quantities of solvent
Model FDL 115 Safety drying chambers for limited quantities of solvent The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and
More informationChilled Beams Selection BY DAN INT-HOUT, FELLOW ASHRAE; AND LILLI WILBAR
This article was published in ASHRAE Journal, November 2014. Copyright 2014 ASHRAE. Reprinted here by permission from ASHRAE at www.krueger-hvac.com This article may not be copied nor distributed in either
More informationPitco SSH75 Large Vat Gas Fryer Performance Tests
Pitco SSH75 Large Vat Gas Fryer Performance Tests Application of ASTM Standard Test Method F 2144-05 FSTC Report 5011.06.18 October 2006 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc. Contributors:
More informationENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET
ENCORE 2G MEDIUM LABORATORY STERILIZER SPECIFICATION/DATA SHEET The Encore 2G Series Laboratory/Scientific Sterilizer was specifically designed to meet the diversified and budgetary needs of our laboratory
More informationModel FD 115 Drying and heating chambers Avantgarde.Line with forced convection
Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection A BINDER FD series Avantgarde.Line heating oven is always used when fast drying and sterilization is required. Thanks to
More informationPitco SSH55 Gas Fryer Performance Tests
Pitco SSH55 Gas Fryer Performance Tests Application of ASTM Standard Test Method F 1361-05 FSTC Report 5011.06.17 October 2006 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc. Contributors:
More informationASTM C 1363 Thermal Performance Test Report
ASTM C 1363 Thermal Performance Test Report Test Number: 2010-50 Sponsor: Butler Research Center Liner System R-25 + R-11 Membrane liner system, R-25 fiberglass insulation between the purlins, R-11 fiberglass
More informationModel BF 720 Incubators Avantgarde.Line with forced convection
Model BF 720 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly
More informationThin-profile, flexible, high-thermal-resistance blanket
Technical Data Sheet Thin-profile, flexible, high-thermal-resistance blanket Features & Benefits Reduces thermal bridging Significantly increases thermal resistance in space-limited situations Enables
More informationOffice Lighting: Title 24 & Technology Update
Office Lighting: Title 24 & Technology Update Supporting compliance with California s Title 24 Standards Nicole Graeber Senior Development Engineer Technical Communications Director negraeber@ucdavis.edu
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2810 Reissued 02/2018 This report is subject to renewal 07/2018. DIVISION: 07 00
More informationMHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 9,000 BTUH. Rev. 1.3
MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 9,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 9,000 BTUH Multiaqua Model
More informationField Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE
Field Accuracy of Temperature Measurements in TAB Work Andrew P. Nolfo, PE The purpose of this article is to discuss the measuring and reporting of temperatures at heat transfer equipment during the Testing
More informationEnergy Recovery Ventilation Equipment
ANSI/AHRI Standard 1060 (I-P) 2014 Standard for Performance Rating of Airto-Air Exchangers for Energy Recovery Ventilation Equipment Approved by ANSI on May 15, 2015 IMPORTANT SAFETY DISCLAIMER AHRI does
More informationSINGLE PACKAGED VERTICAL AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM
SINGLE PACKAGED VERTICAL AIR-CONDITIONERS AND HEAT PUMPS CERTIFICATION PROGRAM AHRI SPVA AND SPVH OM JANUARY 2018 2111 Wilson Blvd, Suite 500 Arlington, Virginia 22201 (703) 524-8800 Sponsored and administered
More informationHEAT PUMP POOL HEATERS CERTIFICATION PROGRAM
HEAT PUMP POOL HEATERS CERTIFICATION PROGRAM AHRI HPPH OM JANUARY 2017 2111 Wilson Blvd, Suite 500 Arlington, Virginia 22201 (703) 524-8800 Sponsored and administered by: PREFACE The following manual outlines
More informationThe Secret Behind Wide Temperature Technology
Abel Lee, Assistant Manager, Hardware R&D Hunter Lin, Project Supervisor, Thermal Department Bruce Chen, Project Supervisor, Marketing Communications support@moxa.com Industrial applications are often
More informationModel BF 260 Incubators Avantgarde.Line with forced convection
Model BF 260 Incubators Avantgarde.Line with forced convection The BINDER incubator of the BF Avantgarde.Line series with forced convection is suitable for all gentle incubation applications, particularly
More informationPERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation
PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation INTRODUCTION As the use of spray polyurethane foam (SPF) insulation is increasing in both
More information2005 Standard for Performance Rating Of Refrigerant Liquid Receivers. ANSI/AHRI Standard (Formerly ARI Standard )
2005 Standard for Performance Rating Of Refrigerant Liquid Receivers ANSI/AHRI Standard 495-2005 (Formerly ARI Standard 495-2005) IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does
More informationStandard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1
Designation: D 1754 97 Standard Test Method for Effects of Heat and Air on Asphaltic Materials (Thin-Film Oven Test) 1 This standard is issued under the fixed designation D 1754; the number immediately
More informationHeating and Cooling Efficiency Program
Terms & Conditions for Incentive Application Customer Information and Agreement Incentive Availability Incentive qualifications and amounts are subject to change or termination at any time. Incentives
More informationPRG366GH 36-INCH GAS PRO HARMONY RANGE PROFESSIONAL SERIES, STANDARD-DEPTH, PORCELAIN COOKTOP SURFACE
Also Available: PRL366GH - LP FEATURES & BENEFITS - Exclusive, patented Star Burner most even heating, unsurpassed flame coverage - QuickClean Base designed for easy surface cleaning - Precision simmering
More informationASTM C THERMAL PERFORMANCE TEST REPORT. Rendered to: WIRE-BOND. SERIES/MODEL: Masonry Tie Thermal Evaluations (2x6 Steel Stud Wall)
ASTM C 1363-11 THERMAL PERFORMANCE TEST REPORT Rendered to: WIRE-BOND SERIES/MODEL: Masonry Tie Thermal Evaluations (2x6 Steel Stud Wall) TYPE: Masonry Wall Assembly Summary of Results Test Unit R-Value
More informationSub Wet-Bulb Evaporative Chiller
Emerging Technologies Sub Wet-Bulb Evaporative Chiller Prepared by: Emerging Products Customer Service Southern California Edison June 2015 Acknowledgments Southern California Edison s Emerging Products
More informationEnergy Performance Systems, Inc.
Energy Performance Systems, Inc. Owner & Developer of the Whole Tree Energy Technology 13 November 2012 Project Title: Improving the Efficiency of Planting, Tending and Harvesting Farm-Grown Trees for
More informationTEST REPORT. Bushfire resistance test of an external wall system to BAL A40 in accordance with AS EWFA Report No:
TEST REPORT Bushfire resistance test of an external wall system to BAL A40 in accordance with AS1530.8.1-2007 EWFA Report No: 38031900.1 Report Sponsor: Ullrich Aluminium PO BOX 246 Carole Park QLD 4300
More informationTC54. for architects & designers. Dimensions Clearances Venting
for architects & designers TC54 Series D Dimensions Clearances enting IMPORTANT This booklet is intended as a basic specification guide for architects, designers and builders. Please refer to the Instruction
More informationFree 17'x6' Chicken Run Plan. Designed for up to 11 chickens
Free 17'x6' Chicken Run Plan Designed for up to 11 chickens Disclaimer The information provided here will show you how to build a chicken coop. However, we at howtoplans.org do not claim that the recommended
More informationApproval Standard. for. Flammable and Combustible Liquid Storage Buildings
Approval Standard for Flammable and Combustible Liquid Storage Buildings Class Number 6049 August 1991 (Effective Date: August 1, 1992) 2002 FM Global Technologies LLC. All rights reserved. Foreword FM
More informationFRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Architectural Decking panels and Fabrications REVISED 11.
FRP Specifications Section 06 73 13 Fiberglass Reinforced Polymer (FRP) Architectural Decking panels and Fabrications REVISED 11.2016 BRISTOL FACILITY 400 Commonwealth Ave., P. O. Box 580, Bristol, VA
More informationRack Power Distribution Unit AP7562, AP7563, AP7564 General Information
Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information Description This booklet provides information on installing and operating the Rack Power Distribution Units (PDUs) AP7562, AP7563,
More informationReading Your Electric Meter
AK Reading Your Electric Meter Target grades: 3-5 AK GLEs: Science Math [3/4/5] SA1.1 [3] E&C-4 [3/4/5] SA1.2 [4/5] E&C-3 [3/4] SA2.1 [3/4/5] S&P-2 Reading [3/4/5] 1.6.1 [3] 1.6.2 Set up time: 15 minutes
More informationSTP-PT-026 GUARANTEED HIGHER STRENGTH PROPERTIES
STP-PT-026 GUARANTEED HIGHER STRENGTH PROPERTIES Date of Issuance: January 29, 2009 This report was prepared as an account of work sponsored by ASME Pressure Technologies Codes and Standards and the ASME
More informationNORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS
PART 1 GENERAL 1.01 SUMMARY Section 15140 PIPE HANGERS, This Section includes the furnishing and subsequent installation of: A. Pipe and equipment hangers, supports, and associated anchors B. Equipment
More informationPitco SGM24-US Gas Fryer Performance Tests
Pitco SGM24-US Gas Fryer Performance Tests Application of ASTM Standard Test Method F 2144-05 FSTC Report 5011.07.18 October 2007 Prepared by: David Cowen David Zabrowski Fisher-Nickel, Inc. Contributors:
More informationA. GENERAL INFORMATION
STATE OF CALIFORNIA Prescriptive Residential Additions 300 Ft 2 or Less, or Additions That Do Not Require HERS Field Verification CEC-CF1R-ADD-05-E (Revised 06/14) CALIFORNIA ENERGY COMMISSION CERTIFICATE
More informationPACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS CERTIFICATION PROGRAM
PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS CERTIFICATION PROGRAM AHRI PTAC AND PTHP OM JANUARY 2018 2111 Wilson Blvd, Suite 500 Arlington, Virginia 22201 (703) 524-8800 Sponsored
More informationModel 5000 Cargo Lift Installation and Operations Manual
Model 5000 Cargo Lift Installation and Operations Manual Congratulations on the purchase of your new SpaceLift Products 5000 cargo lift system. Expect to receive many years of reliable service moving household
More informationTEST REPORT. EVALUATION CENTER Intertek Testing Services NA Inc Murphy Drive Middleton, WI 53562
TEST REPORT REPORT NUMBER: 102741836MID-001bR2 REPORT DATE: October 24, 2016 REVISED REPORT DATE: August 7, 2017 REVISED REPORT DATE: August 11, 2017 REVISED REPORT DATE: September 6, 2017 EVALUATION CENTER
More informationCOOLING TECHNOLOGY INSTITUTE
PAPER NO: TP08-16 CATEGORY: DRY COOLING COOLING TECHNOLOGY INSTITUTE THE COST OF NOISE ROBERT GIAMMARUTI HUDSON PRODUCTS CORPORATION JESS SEAWELL COMPOSITE COOLING SOLUTIONS, LLC The studies and conclusions
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3340 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL
More informationWhite Paper. Nortec Stainless Steel Air Gap Insulation. Written by: William Truong November 9, Updated by: Jake D Aloisio June 22, 2015
White Paper Written by: William Truong November 9, 2010 Updated by: Jake D Aloisio June 22, 2015 Nortec Stainless Steel Air Gap Insulation Introduction Every system should be designed to operate at optimum
More information7730 ParaGuard Electronic Drawer Safe
7730 ParaGuard Electronic Drawer Safe Thank you for choosing the 7730 Paraguard Electronic Drawer Safe by the Paragon Lock and Safe Co. It is perfect for the home, office, or work place. This safe can
More informationCOMMERCIAL FINNED TUBE RADIATION CERTIFICATION PROGRAM
COMMERCIAL FINNED TUBE RADIATION CERTIFICATION PROGRAM AHRI CFTR OM JANUARY 2018 2111 Wilson Blvd, Suite 500 Arlington, Virginia 22201 (703) 524-8800 Sponsored and administered by: PREFACE The following
More informationFRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.
FRP Specifications Section 06 70 00 Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.2016 BRISTOL FACILITY 400 Commonwealth Ave., P. O. Box 580, Bristol, VA 24203-0580
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3462 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00
More informationNEC Acostix. Sound Attenuation Calculations and Design Software. General Information
NEC Acostix Sound Attenuation Calculations and Design Software General Information NEC Acostix TM is an Excel-Based programmable sheets to help engineers and manufacturers design acoustic enclosures, rectangular
More informationNew Construction Lighting Application. Application Process. Details & Instructions
New Construction Lighting Application Details & Instructions PSO provides technical assistance and rebates to assist businesses in making energy saving upgrades. Review details and requirements* at PowerForwardWithPSO.com.
More informationFIBERGLASS BATTS ACHIEVING GRADE I INSULATION WITH. Prepared by
ACHIEVING GRADE I INSULATION WITH FIBERGLASS BATTS Prepared by ENERGY STAR is a registered trademark of the Environmental Protection Agency Advanced Energy Corporation, under contract with Owens Corning
More informationWM2013 Conference, February 24-28, 2013, Phoenix, Arizona, USA
Development and Application of an Oversize Reusable DOT 7A Type A Overpack Container at the Y-12 National Security Complex - 13150 Tim Tharp*, David Martin**, and Paul Franco*** *B&W Technical Services
More informationSINGLE SWING DOOR PAIRED SWING DOOR
Rev. 091416 SINGLE SWING DOOR PAIRED SWING DOOR Drawing No.: Revision: Date: If you need to contact Customer Service Please complete the following information and retain for future reference: Serial Number:
More informationNuScale Small Modular Reactors:
PNWER Energy Working Group July 25, 2017 NuScale Small Modular Reactors: Advanced, Scalable, Flexible, Economic Charles Marcinkiewicz Director, Marketing NuScale Power, LLC NuScale Nonproprietary Copyright
More informationTruTech Technical Training
TruTech Technical Training Understanding Equipment Operation The rest of the story. Part IV Going where no technician has gone before There are no theories in HVAC/R! Air conditioning is made of scientific
More informationTitle: Sources of Temperature Variance in Dispenser Cathodes
This technical paper was written and developed when the author(s) was an employee of Semicon Associates, a Ceradyne, Inc. company. Ceradyne, Inc. was acquired by 3M Company on November 28, 2012. Title:
More informationEVALUATION AND DESIGN OF DOWNHOLE HEAT EXCHANGERS FOR DIRECT APPLICATION
EVALUATION AND DESIGN OF DOWNHOLE HEAT EXCHANGERS FOR DIRECT APPLICATION Gene Culver Oregon Institute of Technology Klamath Falls, Oregon Gordon M. Reistad Oregon State University Corvallis, Oregon ABSTRACT
More informationCalifornia Commercial Market Share Tracking Study
Report California Commercial Market Share Tracking Study Prepared for California Public Utilities Commission Itron, Inc. 11236 El Camino Real San Diego, California 92130 (858) 724-2620 November 13, 2014
More informationTEST REPORT ON. TESTED FOR: Central States Manufacturing, Inc. 302 Jane Place Lowell, AR Telephone: (800) Fax: (800)
TEST REPORT ON CENTRAL STATES MANUFACTURING, INC. S PANEL-LOC PLUS PANELS (26 GA., 80 KSI, 36" WIDE) FASTENED TO WOOD SUPPORTS AT 2' 0" PANEL SPANS IN ACCORDANCE WITH ASTM E455-11 AND AISI S907-08 TESTED
More informationFAX: Title of Presentation: Criticality Measurements for SNM Accountability
Title of Presentation: Criticality Measurements for SNM Accountability Authors: Joetta Bohman, E. Ray Martin, Ken Butterfield, Richard Paternoster Institution: Los Alamos National Laboratory FAX: 505-665-3657
More informationNYSERDA CHP Assessment Report A S S E S S I N G T H E C H P P L A N T A T T O R E N C O N D O M I N I U M S
NYSERDA CHP Assessment Report A S S E S S I N G T H E C H P P L A N T A T T O R E N C O N D O M I N I U M S October 9, 2013 Toren Condominiums Toren Condominiums DISCLAIMER OF WARRANTY Information contained
More informationClarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12
Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12 February 2012 Legal Notice - Disclaimer and exclusion of liability This document is provided
More informationResidential Plan Review for New One and Two Family Dwellings
The following is a list of items that are normally included in a set of construction drawings for one and two family dwellings. The items in bold depict those items that will be reviewed for during the
More informationNYSERDA CHP Assessment Report A S S E S S I N G T H E C H P P L A N T A T C O - O P C I T Y - R I V E R B A Y
NYSERDA CHP Assessment Report A S S E S S I N G T H E C H P P L A N T A T C O - O P C I T Y - R I V E R B A Y October 9, 2013 Co-op City - Riverbay Coop City - Riverbay DISCLAIMER OF WARRANTY Information
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 4073 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00
More informationModel 5200 Cargo Lift Installation and Operation Manual
Model 5200 Cargo Lift Installation and Operation Manual Congratulations on the purchase of your new SpaceLift Products 5200 cargo lift system. Expect to receive many years of reliable service moving household
More informationSample Report BAKER ENGINEERING AND RISK CONSULTANTS, INC.
BAKER ENGINEERING AND RISK CONSULTANTS, INC. 3330 Oakwell Court, Suite 100 San Antonio, TX 78218-3024 Tel. (210) 824-5960 Fax: (210) 824-5964 www.bakerrisk.com Mr. Aaron Westover Vice President Rigid Global
More informationTHIRD PARTY STUDY INTO TYPES OF DEGRADATION ACROSS LEADING MANUFACTURERS
NE-18-1 THIRD PARTY STUDY INTO TYPES OF DEGRADATION ACROSS LEADING MANUFACTURERS Results of an independent third party study into the effects of LID and PID on the performance of solar panels from leading
More informationCHECK-TEMP CALIBRATORS
TEL-TRU MANUFACTURING COMPANY CHECK-TEMP CALIBRATORS Simplify How You Verify! Use with thermometer probes of all sizes! Quick - Easy - Accurate www.teltru.com Verify Thermometer Accuracy at Your Critical
More informationWhere Does It All Go?
Where Does It All Go? Using Simple Loggers to Dis-aggregate Whole Building Energy Data Ryan Stroupe, Pacific Energy Center April 2, 26 San Francisco, California Topics Covered Here Value of baselining
More informationTechna-Duc. Advantages. Features and Benefits. LEED Eligible Product
Techna-Duc Advantages Techna-Duc is shop fabricated and installed with minimal field alterations. Panels are constructed with polyisocyanurate insulation products that do not promote the growth of mold
More informationWind Turbine Generator System Acoustic Noise Test Report. Bergey Excel Wind Turbine
June 2003 NREL/EL-500-33833 Wind Turbine Generator System Acoustic Noise Test Report for the Bergey Excel Wind Turbine By National Wind Technology Center National Renewable Energy Laboratory 1617 Cole
More informationOverview of Alstom s Chemical Looping Programs
Overview of Alstom s Chemical Looping Programs Frank Kluger, I. Abdulally, H. Andrus, A. Levasseur, C.Beal, J.Marion 5 Th Meeting of the IEAGHG International Oxyfuel Combustion Research Network Wuhan,
More informationA Systematic Approach to Improving Heater Absorbed Duty
A Systematic Approach to Improving Heater Absorbed Duty Texas Industrial Energy Management Forum S. Chatterjee March 1, 2012 lyondellbasell.co m lyondellbasell.co m Company Profile LyondellBasell is One
More informationProduct Booklet Keen K-1000CS FCAW Wire Coil and TIG Filler Wire Storage Oven Floor Positioned
Product Booklet Keen K-1000CS FCAW Wire Coil and TIG Filler Wire Storage Oven Floor Positioned Purpose: To prevent moisture contamination in spooled welding wire and TIG filler rods Capacity: 8 / 10 lb
More informationLarge University Central Chiller Plant Design Considerations
Carrier Engineering Newsletter Volume 5, Issue 3 Large University Central Chiller Plant Design Considerations Large campus chilled water plants have unique constraints and need careful evaluation for successful
More informationPotential Energy Savings from Optimized Schedule & Economizer Cycles in the Moody Library Building at UTMB
ESL-TR-93/10-08 Potential Energy Savings from Optimized Schedule & Economizer Cycles in the Moody Library Building at UTMB Submitted to the by the Monitoring and Analysis Group (Task E) Dr. Mingsheng Liu
More informationSECTION ALUMINUM STORM WINDOWS
PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable
More informationDIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations
DIVISION 11 - EQUIPMENT 11400 FOOD SERVICE EQUIPMENT A. Design Considerations 1. The A/E shall use the services of a food service equipment specialist in preparation of kitchen areas and other food preparation
More informationPage of ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine
ENGINEERING DATA - HOT WATER CAPACITIES, CALCULATIONS AND CORRECTION FACTORS Use the following two tables to determine The performances reflected in these tables are based on 1. Heating Capacity (MBH)
More informationEXETER TOWNSHIP HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS
HOOD AND DUCT SYSTEMS FOR COMMERCIAL KITCHENS POLICY STATEMENT This policy applies to NEW Hood and Duct systems. The Authority Having Jurisdiction will not waive major criteria in the applicable standards
More information