1 Roma to Brisbane Pipeline Dalby Compressor Station Upgrade Environmental Management Plan Appendix 8 Noise Assessment PR Rev 0; June 2011

2 PR Rev 0; June 2011 Roma to Brisbane Pipeline Dalby Compressor Station Upgrade Environmental Management Plan

3 Sonus Pty Ltd 17 Ruthven Avenue ADELAIDE SA 5000 Phone: (08) Facsimile: (08) ABN: APA DALBY COMPRESSOR STATION Proposed Extension Prepared For RPS 743 Ann Street, Fortitude Valley, Brisbane, QLD 4006.

4 PAGE 2 GLOSSARY Background noise level Background creep CONCAWE db(a) Equivalent noise level L A10 L A90 L Aeq L Aeq, 1 hour L Aeq, adj, 1 hour L pa,lf RBL Sensitive receptor Sound power level WHO Worst Case Noise level in the absence of intermittent noise sources The gradual increase in background noise levels in an area as a result of successive developments generating constant noise levels at a particular location. The oil companies international study group for conservation of clean air and water Europe The propagation of noise from petrochemical complexes to neighbouring communities A weighted noise level measured in decibels. A weighting is a frequency adjustment representing the response of the human ear Energy averaged noise level A weighted noise level exceeded 10% of the time, representing the typical upper noise level A weighted noise level exceeded 90% of the time, representing the background noise level A weighted equivalent noise level measured in decibels A weighted equivalent noise level measured in decibels over a period of 1 hour A weighted equivalent noise level measured in decibels over a period of 1 hour and adjusted for tonality Indoor low frequency A weighted noise level Rating Background Level A location in the vicinity of the proposed development, where noise may affect the amenity of the land use. For the proposed development, sensitive receptors are generally dwellings. A measure of the sound energy emitted from a source of noise. World Health Organisation Conditions resulting in the highest noise level at or inside dwellings. Worst case meteorological conditions can be characterised as no cloud at night with wind from the project site to dwellings. Worst case building construction refers to a façade constructed from light weight materials providing the lowest noise reduction across it.

5 PAGE 3 TABLE OF CONTENTS GLOSSARY... 2 TABLE OF CONTENTS INTRODUCTION DESCRIPTION OF EXISTING ENVIRONMENT METEOROLOGICAL CONDITIONS AND ATMOSPHERIC EFFECTS CRITERIA ENVIRONMENTAL PROTECTION (NOISE) POLICY PLANNING FOR NOISE CONTROL GUIDELINE WORLD HEALTH ORGANISATION GUIDELINES LOW FREQUENCY NOISE DRAFT GUIDELINE SUMMARY OF CRITERIA ASSESSMENT NOISE SOURCES ADDITIONAL ACOUSTIC ATTENUATION PREDICTED NOISE CONCLUSION REFERENCES APPENDIX A: SENSITIVE RECEPTORS IN THE VICINITY OF THE FACILITY APPENDIX B: NOISE CONTOUR... 24

6 PAGE 4 1 INTRODUCTION The APA Dalby Compressor Station is located near the township of Dalby. The APA Group is proposing to extend the capacity of the facility involving the installation of two new compression units. Sonus has been engaged to make an assessment of the environmental noise from the proposed extension to the Dalby Compressor Station. The assessment has consisted of: a survey of the existing acoustic environment and equipment on site; measurements of the noise from the existing compressor; a prediction of the noise from the new compressors on site at the closest sensitive receptors; a comparison of the predicted levels with the relevant environmental noise criteria, and; recommendations for acoustic treatment measures. The new gas compression units will comprise a compressor and the associated drive equipment. The gas compression units have the potential to operate continuously.

7 PAGE 5 2 DESCRIPTION OF EXISTING ENVIRONMENT The Dalby Compressor Station is located near the township of Dalby. At sensitive receptors, the acoustic environment is characterised by local and distant road traffic and natural noise sources such as wind in trees and birds. This results in a low noise environment, typical of a rural setting, except where a receptor is located in close proximity to the compressor station or roads. Appendix A provides the coordinates and approximate distances of the sensitive receptors considered in this assessment. The topography between the site and the sensitive receptors is relatively flat and it is expected that the topography will have negligible influence on the noise predicted at the closest sensitive receptors. Background noise levels (L A90 ) were measured at a location which was selected to be indicative of nearby residences. The location was not influenced by any existing fixed noise sources and was an equivalent distance to roads as most residences. The measurements were made between the 18 th and the 27 th of October, 2010, in accordance with the Queensland Department of Environment and Resource Management s (DERM) Noise Measurement Manual (the DERM Noise Measurement Manual). Using the measurement data obtained, the Rating Background Levels (RBL) were calculated in accordance with the Planning for Noise Control Guideline released by DERM. The calculated RBLs are summarised in Table 2.1. Table 2.1: Calculated Rated Background Levels. RBL db(a) Day Evening Night

8 PAGE 6 The RBL is determined from the lower tenth percentile of the L A90 noise level in the environment and effectively represents the lulls. That is, the RBL is representative of the quietest periods at the monitoring location. The calculated RBLs are considered to be representative of all sensitive receptors which are located in an environment dominated by distant traffic noise and natural noise sources such as wind in trees and birds. Under certain conditions, an existing compressor unit located at the station can contribute to the noise level at the sensitive receptors. Noise from the existing compressor was measured in the vicinity of the site on the 22 nd of October, These measurements were used to estimate noise from the existing compressor at the sensitive receptors As the RBL represents the lowest 10% of the L A90 noise level, existing noise sources will not contribute to the RBL unless noise levels are significant during upwind conditions. To determine the influence of the existing compressor on the RBL at each sensitive receptor, predictions have been conducted under mild upwind conditions. Based on the predictions, noise from the existing compressor only significantly influences the RBL at residence R1.

9 PAGE 7 3 METEOROLOGICAL CONDITIONS AND ATMOSPHERIC EFFECTS The CONCAWE noise propagation model is used around the world and is widely accepted as an appropriate model for predicting noise over significant distances. The CONCAWE system divides the range of possible meteorological conditions into six separate weather categories, from Category 1 to Category 6. Weather Category 1 provides best-case (i.e. lowest noise level) weather conditions for the propagation of noise, whilst weather Category 6 provides worst-case (i.e. highest noise level) conditions, when considering wind speed, wind direction, time of day, and level of cloud cover. Weather Category 4 provides neutral weather conditions for noise propagation. For the purposes of comparison, Categories 1, 2 and 3 weather conditions are generally characterised by wind blowing from the receptor to the noise source during the daytime with little or no cloud cover. Category 4 conditions can be characterised by no wind and an overcast day, whilst no wind and a clear night sky represent Category 5 conditions. Category 6 conditions can be characterised by a clear night sky and wind blowing from the noise source to the receptor. In the particular circumstances of this development, it is noted that the noise levels experienced at sensitive receptors in the vicinity of the facility will be significantly affected by the weather category. For example, higher noise levels would be expected at sensitive receptors with wind blowing from the site to the sensitive receptor (i.e. Category 5 or 6 conditions) than with wind blowing from the sensitive receptor to the site (i.e. Category 1, 2, or 3 conditions). Twelve months of historical meteorological data for Dalby were processed to determine the likelihood of each meteorological category. The times during which the wind speed is greater than 5m/s have been listed separately and excluded from each category, as it is anticipated that ambient noise levels (from wind in trees) would mask the noise from the site at these times.

10 PAGE 8 Tables 3.1 to 3.4 summarise the percentage of time in each meteorological category for the closest sensitive receptor located to the north of the site (most critical receptor), and for sensitive locations to the northeast, east and south of the site. Table 3.1: Distribution of meteorological categories for sensitive receptor located to the north of the site. Meteorological Category Total Percentage of Time in Each Category Wind Speed > 5m/s 16% 5% Category 1 1% 0% Category 2 10% 7% Category 3 17% 16% Category 4 24% 29% Category 5 23% 28% Category 6 9% 15% Percentage of Time in Each Category during Night-time Only Table 3.2: Distribution of meteorological categories for sensitive receptor located to the northeast of the site. Meteorological Category Total Percentage of Time in Each Category Wind Speed > 5m/s 16% 5% Category 1 2% 0% Category 2 12% 8% Category 3 26% 29% Category 4 24% 35% Category 5 12% 12% Category 6 8% 11% Percentage of Time in Each Category during Night-time Only Table 3.3: Distribution of meteorological categories for sensitive receptor located to the east of the site. Meteorological Category Total Percentage of Time in Each Category Wind Speed > 5m/s 16% 5% Category 1 2% 0% Category 2 13% 6% Category 3 22% 28% Category 4 25% 35% Category 5 15% 15% Category 6 8% 11% Percentage of Time in Each Category during Night-time Only

11 PAGE 9 Table 3.4: Distribution of meteorological categories for sensitive receptor located to the south of the site. Meteorological Category Total Percentage of Time in Each Category Wind Speed > 5m/s 16% 5% Category 1 1% 0% Category 2 5% 1% Category 3 18% 18% Category 4 23% 27% Category 5 22% 24% Category 6 15% 25% Percentage of Time in Each Category during Night-time Only For compliance testing, the DERM Noise Measurement Manual requires that the noise measurement be conducted during fine weather conditions with calm to light winds. Measurement during conditions conducive to sound propagation should only be conducted if the conditions are a true representation of the normal situation in the area. When conducting a noise prediction, it is therefore considered appropriate that the prediction is also made for fine weather conditions, unless conditions conducive to sound propagation are representative of the normal conditions in the area. To objectively determine whether the meteorological conditions conducive to sound propagation are a representation of the normal conditions of an area, reference is made to the Planning for Noise Control Guideline. The Planning for Noise Control Guideline states that the meteorological conditions conducive to sound propagation, such as temperature inversions (Categories 5 and 6) and downwind conditions will be a significant feature of the area if they occur for 30% of the time. Therefore based on Table 3.1, Categories 5 and 6 weather conditions are considered to be a feature of the area at the most critical receptor. Consequently, it is proposed that the assessment of noise at all sensitive receptors in the vicinity of the facility be made under worst-case (CONCAWE Category 6) meteorological conditions.

12 PAGE 10 4 CRITERIA The Environmental Protection (Noise) Policy 2008 has been used as the primary method of objectively assessing the noise from the proposal. However, reference is also made to the World Health Organisation (WHO) Guidelines, the DERM Planning for Noise Control Guideline and the DERM Assessment of Low Frequency Noise Draft Guideline. 4.1 Environmental Protection (Noise) Policy 2008 The Environmental Protection (Noise) Policy 2008 (the Policy) provides the management intent to control background noise creep as well as achieve acoustic quality objectives for sensitive receptors. A traditional approach to environmental noise has been to measure existing background noise levels 1 prior to a development and to set environmental noise criteria at a certain level above the existing background noise level. Where this methodology is used, background noise levels are measured over a period of time to incorporate a range of meteorological conditions. The background noise level used is at the lower end of the range of measured levels. One of the concerns about this methodology is that each development may increase the background noise level allowing more relaxed criteria for future developments. This theoretical phenomenon of the degradation of the acoustic environment with successive developments is known as background creep. For this development to contribute to background creep, successive developments would need to rely on background noise levels, which have been elevated by previous projects, to set less stringent criteria. 1 For the purposes of this report the background noise level is represented by the RBL.

13 PAGE 11 To control background creep, the Policy includes: To the extent that it is reasonable to do so, noise from an activity must not be (a) For noise that is continuous noise measured by L A90,T - more than nil db(a) greater than the existing acoustic environment measured by L A90,T ; or (b) For noise that varies over time measured by L Aeq,adj,T - more than 5 db(a) greater than the existing acoustic environment measured by L A90T. As the noise from the proposal is expected to be continuous, it is part (a) that applies. Based on the measured background noise levels, the criteria associated with controlling background creep are shown in Table 4.1. Table 4.1: Criteria to control background creep. L A90,T db(a) Day Evening Night Since the development of the WHO Guidelines, it has become more common for regulatory authorities to base environmental noise criteria on avoiding health and wellbeing impacts rather than comparison with background noise levels. The Policy includes acoustic quality objectives based on the WHO Guidelines. These are described in Table 4.2. Sensitive Receptor Table 4.2: The Environmental Protection (Noise) Policy acoustic quality objectives. dwelling (for outdoors) dwelling (for indoors 4 ) Note: Time of Day daytime¹ and evening² daytime and evening Acoustic Quality Objectives (db(a))* L Aeq,adj,1hr L A10,adj,1hr L A1,adj,1hr Environmental Value health and wellbeing health and wellbeing night-time³ health and wellbeing in relation to the ability to sleep * Measured at the sensitive receptor. ¹ Daytime is defined by the Policy as the period after 7am on a day to 6pm on the day. ² Evening is defined by the Policy as the period after 6pm on a day to 10pm on the day. ³ Night-time is defined by the Policy as the period after 10pm on a day to 7am on the next day. 4 In accordance with the WHO Guidelines, indoor noise levels can be converted to outdoor levels by the addition of 15 db(a) assuming windows being partially open for ventilation.

14 PAGE 12 The noise from the existing compressor is predicted to be 41 db(a) at residence R1 under worst case conditions. As the noise from the existing compressor dominates the noise level at residence R1, it is not relevant to assess noise from the proposed compressors against the RBLs at a location not influenced by the existing compressor. In accordance with the intent of the Policy, the total noise from the site (including the existing and proposed compressors) should achieve a level of 41 db(a) in order to prevent background noise creep. 4.2 Planning for Noise Control Guideline At locations not influenced by industrial noise sources, the DERM Guideline specifies a criterion based on the RBL, plus an adjustment of 3 db(a) for the conversion to an equivalent (L Aeq ) noise level. Therefore, based on the measured RBLs, the most stringent (night time) criterion is 29 db(l Aeq ) for residences R2-R9. At locations where industrial noise sources are present, the DERM Guideline protects against background noise creep by setting a criterion that results in no increase in the local noise level. In situations where there is no opportunity to reduce existing noise levels, noise from the proposed compressors should be limited to 10 db(a) below any existing noise source. However, it is expected that acoustic treatment incorporated in the expansion will also reduce the noise from the existing compressor at residence R1. Under these circumstances it is proposed that the total noise (existing and proposed compressors) from the compressor station is to achieve the existing level of 41 db(a), thereby achieving the intent of the DERM Guideline.

15 PAGE World Health Organisation Guidelines The WHO has developed guidelines 2 for community noise in specific environments. With respect to annoyance, the guidelines state: To protect the majority of people from being seriously annoyed during the daytime, the sound pressure level on balconies, terraces and outdoor living areas should not exceed 55 db L Aeq for a steady continuous noise. To protect the majority of people from being moderately annoyed during the daytime, the outdoor sound pressure level should not exceed 50 db(a) L Aeq. To avoid sleep disturbance, the WHO suggests that the equivalent noise level (L Aeq ) should be limited to 30 db(a) inside a bedroom at night. Based on the windows being partially open, the WHO suggests that to achieve the internal level described above, the equivalent noise level outside a bedroom window should be limited to 45 db(a). Sonus has conducted tests of the noise reduction achieved across the facade of a number of dwellings. These tests include a range of facade constructions from light weight transportable homes to masonry homes. The results of the testing indicate that with windows partially open for ventilation, the noise transfer is typically around 15 db(a). The tests confirms that the WHO noise reduction of 15 db(a) across a facade is appropriate. 4.4 Low Frequency Noise Draft Guideline The noise from the proposed new equipment is not dominated by low frequency noise (refer Table 5.1) but the propagation of sound over large distances attenuates the high and mid frequencies, leaving a greater low frequency component and therefore as a conservative approach, assessment against the suggestions of the Low Frequency Noise Draft Guidelines has been included. 2 Berglund, Lindvall and Schwela, 1999, Guidelines for Community Noise

16 PAGE 14 The draft guideline separates the assessment of low frequency noise based on the frequency content of the noise and whether the noise is tonal or broad band. Based on measurements of similar equipment at other sites, the noise experienced at sensitive receptors will not include a significant component of infrasound (less than 20Hz) and will not be tonal. For non-tonal, low frequency noise in the range of 20Hz to 200Hz, the draft guideline suggests that the noise is considered to be acceptable if the contribution of low frequency noise within a sensitive receptor (L pa,lf ) does not exceed 20 db(a) during the evening or night and 25 db(a) during the day. The low frequency noise transfer from outside to inside sensitive receptors varies significantly based on the construction of the dwelling. Sonus has recently conducted tests of the noise reduction achieved across the facade of a number of dwellings. The results from these tests indicate that the low frequency noise reduction, with windows partially open, ranges from 10 db(a) for a light weight transportable home to 20 db(a) for a well constructed masonry home. This assessment has been based on a noise reduction of 10 db(a), which represents a worst-case (conservative) assessment. 4.5 Summary of Criteria The Policy, the DERM Guidelines and the recommendations of the WHO Guidelines have been considered in determining appropriate criteria for the proposed extension. It is common practice for noise from industrial sources to be predicted as an equivalent level (L Aeq ), therefore the criteria provided in Table 4.1 require adjusting from the provided L A90 levels. A regularly accepted adjustment is an addition of 3 db(a) for the conversion of an L A90 to an L Aeq noise level, an example of which is contained within the Planning for Noise Control Guideline.

17 PAGE 15 With consideration to the existing ambient noise environment and the existing compressor located on site, it is proposed that that the following criteria are established to ensure compliance at each noise sensitive location: Residence R1: Noise from both the existing and proposed compressors to achieve an outdoor level of 41 db(a); and, Residences R2-R9: Noise from the proposed compressors to achieve a level of 29 db(a). Where the above criteria are achieved, the intent of the Environmental Protection (Noise) Policy 2008, the World Health Organisation (WHO) Guidelines and the DERM Planning for Noise Control Guideline will also be achieved.

18 PAGE 16 5 ASSESSMENT 5.1 Noise Sources It is proposed that two Solar Centaur 50 compression units are to be installed at the Dalby Compressor Station. Table 5.1 below contains sound power levels for each item of equipment provided by the manufacturer of the compressors. Table 5.1: Main noise sources and sound power levels Noise Source Unsilenced Combustion Air Inlet Unsilenced Combustion Exhaust Unenclosed Package Maximum Sound Power Level (db(a) re 1 pw) by Octave Band Frequency (Hz) Total (db(a)) Additional Acoustic Attenuation Noise from the operation of the new gas compression units at the sensitive receptors in the vicinity of the site has been predicted using the CONCAWE noise propagation model in the SoundPlan noise modelling software. The CONCAWE propagation model takes into account topography, ground absorption and meteorological conditions, and has been used and accepted around the world as an appropriate sound propagation model. In the noise model, flat ground was considered as the attenuation due to undulating ground surface is considered negligible at the closest sensitive receptor. Based on the predicted noise from the proposed compressors it is required that additional acoustic attenuation be applied to the standard measures included in Table 5.1. The additional acoustic treatment is required to ensure compliance with the relevant criteria and is summarised below:

19 PAGE 17 Replace the standard inlet silencer with a silencer that provides an equivalent acoustic performance to that provided in Table 5.2; Replace the standard exhaust silencer with a silencer that provides an equivalent acoustic performance to that provided in Table 5.2. A suitable example is a Colpro 750 series silencer; Enclose the package with the standard enclosure specified by the manufacturer, such that the sound power levels provided in Table 5.2 are not exceeded; Build an acoustic barrier from compressed fibre cement with a minimum thickness of 18mm, located no greater than 6m from the enclosed package. The barrier should block line of sight between the enclosed package and the closest residence and be at least 35m in length and a height of at least 1.5m above the height of the of the enclosed package and air inlet. The barrier should be sealed airtight from the ground to the full height of the barrier; and, Acoustic insulation should be installed on the acoustic barrier described above. The insulation should be 50mm thick with a minimum density of 32 kg/m 3. This insulation may be protected with a perforated material (such as sheet steel or fibre cement sheeting) with an open area of at least 15%, a diagram of the proposed construction is provided below. Weatherproof capping 50mm thick acoustic insulation with a minimum density of 32 kg/m 3 Compressor Station Side Perforated material (e.g. sheet steel, fibre cement sheet) with an open area > 15% spaced from the insulation to provide weatherproofing Acoustic Barrier

20 PAGE 18 Table 5.2: Additional Acoustic Treatment. Frequency (Hz) Total Inlet Silencer (Insertion Loss) (db) Exhaust Silencer (Insertion Loss) (db) Enclosed Package (SWL (db(a)) Alternatively, the criteria could be achieved without the use of a barrier adjacent to the new compressors by installing all three of the following additional measures: An acoustic enclosure around the proposed compressors that performs significantly better than the manufacturer s standard enclosure; An air inlet attenuator that performs significantly better than the manufacturer s standard attenuator; Additional attenuation to the existing compressor, which may take the form of a small barrier to block line of sight to the cooling fan. 5.3 Predicted Noise The noise levels outside of dwellings R2-R9 have been predicted under worst case meteorological conditions, from the operation of the new compressor units and the acoustic treatment incorporating the noise barrier. The noise level at each sensitive receptor is summarised in Table 5.3 and a noise contour is provided in Appendix B, based on the sound power levels of the equipment listed in Table 5.1 and the additional acoustic attenuation provided above.

21 PAGE 19 Table 5.3: Predicted Noise Level Outside the Dwellings. Sensitive Receptor Predicted Noise Level (db(a)) R2 28 R3 26 R4 23 R5 21 R6 18 R7 15 R8 16 R9 18 In addition, the low frequency noise level inside dwellings R2-R9 is below 20 db(a). Therefore, it is predicted that the compressor station will comply with the low frequency noise draft guideline at each of these dwellings. The noise level at residence R1 has been predicted under worst case conditions, due to the simultaneous operation of the existing and proposed compressors. The total predicted noise level from the compressor station is 40 db(a), less than the existing noise level at residence R1. It is predicted that the low frequency noise level inside residence R1 from the operation of the compressor station following installation is no greater than the level prior to the extension.

22 PAGE 20 6 CONCLUSION An assessment has been made of the noise from the proposed compressors at the APA Dalby Compressor Station. The assessment considered noise from both the existing and proposed compressors at the facility. Based upon the Environmental Protection (Noise) Policy, appropriate conditions for noise levels at sensitive receptors have been determined, taking into consideration the existing acoustic environment. The proposed noise conditions for the operation of the facility are: Residence R1: Noise from both the existing and proposed compressors to achieve an outdoor level of 41 db(a); and, Residences R2-R9: Noise from the proposed compressors to achieve a level of 29 db(a). The noise at the sensitive receptors in the vicinity of the site from the operation of the compressor station has been predicted. The predictions indicate that the proposed noise conditions for the operation of the facility will be achieved at all sensitive receptors, with a feasible level of acoustic treatment applied. The acoustic treatment outlined in this report comprises: Attenuators fitted to the air inlet and exhaust of the proposed compressors; Enclosing the proposed compressors with a standard package specified by the manufacturer; and The construction of an acoustic barrier adjacent to the proposed compressors.

23 PAGE 21 Alternatively, the criteria could be achieved without the use of a barrier adjacent to the new compressors by installing all three of the following additional measures: An acoustic enclosure around the proposed compressors that performs significantly better than the manufacturer s standard enclosure; An air inlet attenuator that performs significantly better than the manufacturer s standard attenuator; and, Additional attenuation to the existing compressor, which may take the form of a reduced barrier to block line of sight to the cooling fan. With the above acoustic treatment in place, the APA Dalby Compressor Station will satisfy the intent of: The Environmental Protection (Noise) Policy 2008; The World Health Organisation (WHO) Guidelines; The DERM Planning for Noise Control Guideline; and, The DERM Assessment of Low Frequency Noise Draft Guideline.

24 PAGE 22 REFERENCES Berglund,B., Lindvall, T., and Schwela, D.H Guidelines for Community Noise. World Health Organisation, Geneva. DERM Guideline Planning for noise control. Department of Environment and Resource Management, Queensland Government, Brisbane, Queensland. DERM Draft Guideline - Assessment of Low Frequency Noise. Department of Environment and Resource Management, Queensland Government, Brisbane, Queensland. Manning, C.J The propagation of noise from petrochemical complexes to neighbouring communities. CONCAWE - The oil companies international study group for conservation of clean air and water Europe. Queensland Government Environmental Protection (Noise) Policy Reprint No.1. Queensland Government, Brisbane, Queensland. Queensland Government Noise Measurement Manual. Third Edition. March. Environment Protection Authority, Queensland Government, Brisbane, Queensland.

25 PAGE 23 APPENDIX A: SENSITIVE RECEPTORS IN THE VICINITY OF THE FACILITY Table A1: Coordinates and Approximates Distances of the Sensitive Receptors from the Site. Sensitive Receptor Easting (WGS 84) Northing Approximate Distance from the Site (m) R R R R R R R R R

26 PAGE 24 APPENDIX B: NOISE CONTOUR R9 R8 R7 R6 R1 R3 R4 R5 R2

Surat Gas Project. Noise and Vibration Impact Assessment

Surat Gas Project. Noise and Vibration Impact Assessment Sonus Pty Ltd 17 Ruthven Avenue ADELAIDE SA 5000 Phone: (08) 8231 2100 Facsimile: (08) 8231 2122 www.sonus.com.au ABN: 67 882 843 130 Surat Gas Project Noise and Vibration Impact Assessment Prepared For

More information

Project: FONTERRA STIRLING. Prepared for: Fonterra Limited PO Box 459 Hamilton Attention: Brigid Buckley. Report No.

Project: FONTERRA STIRLING. Prepared for: Fonterra Limited PO Box 459 Hamilton Attention: Brigid Buckley. Report No. FONTERRA STIRLING PROPOSED NOISE CONTROL BOUNDARY Rp 001 2016009C 20 September 2016 Level 369 Cambridge Terrace PO Box 4071 Christchurch 8140 New Zealand T: +64 3365 8455 F: +64 33658477 www.marshallday.com

More information

Santos LNG Facility Noise Assessment

Santos LNG Facility Noise Assessment F4 Noise REPORT 20-2014-R7 Revision 1 Santos LNG Facility Noise Assessment PREPARED FOR URS Australia Pty Ltd Level 16, 240 Queen Street Brisbane QLD 4000 9 NOVEMBER 2009 HEGGIES PTY LTD ABN 29 001 584

More information

11. NOISE AND VIBRATION

11. NOISE AND VIBRATION 11. NOISE AND VIBRATION This chapter describes the supplementary noise and vibration impact assessment undertaken to address changes made to the project description after the EIS (Coffey Environments,

More information

WIND FARMS TECHNICAL PAPER. Environmental Noise. Prepared for. CLEAN ENERGY COUNCIL Suite 201, 18 Kavanagh Street SOUTHBANK 3006

WIND FARMS TECHNICAL PAPER. Environmental Noise. Prepared for. CLEAN ENERGY COUNCIL Suite 201, 18 Kavanagh Street SOUTHBANK 3006 Sonus Pty Ltd 17 Ruthven Avenue ADELAIDE SA 5000 Phone: (08) 8231 2100 Facsimile: (08) 8231 2122 www.sonus.com.au ABN: 67 882 843 130 WIND FARMS TECHNICAL PAPER Prepared for CLEAN ENERGY COUNCIL Suite

More information

The Clem7 Motorway Tunnel: Mechanical and Electrical Plant Acoustic Design and Performance

The Clem7 Motorway Tunnel: Mechanical and Electrical Plant Acoustic Design and Performance Paper Number 67, Proceedings of ACOUSTICS 2011 2-4 November 2011, Gold Coast, Australia The Clem7 Motorway Tunnel: Mechanical and Electrical Plant Acoustic Design and Performance Claire Richardson and

More information

Analysis of wind turbine low frequency noise prediction accuracy

Analysis of wind turbine low frequency noise prediction accuracy Analysis of wind turbine low frequency noise prediction accuracy Tom EVANS 1 ; Jonathan COOPER 1 ; Vahid ALAMSHAH 1 1 Resonate Acoustics, Australia ABSTRACT Some regulatory authorities in Australia have

More information

ASSESSMENT OF INWARD TRAFFIC NOISE IMPACT AT RESIDENTIAL DEVELOPMENT, WONDERFUL BARN, LEIXLIP, CO. KILDARE

ASSESSMENT OF INWARD TRAFFIC NOISE IMPACT AT RESIDENTIAL DEVELOPMENT, WONDERFUL BARN, LEIXLIP, CO. KILDARE ASSESSMENT OF INWARD TRAFFIC NOISE IMPACT AT RESIDENTIAL DEVELOPMENT, WONDERFUL BARN, LEIXLIP, CO. KILDARE Technical Report Prepared For Ardstone Capital Ltd. 48 Fitzwilliam Square Dublin Technical Report

More information

WAIKATO POWER PLANT SH31, KAWHIA ROAD OTOROHANGA ASSESSMENT OF NOISE EFFECTS

WAIKATO POWER PLANT SH31, KAWHIA ROAD OTOROHANGA ASSESSMENT OF NOISE EFFECTS 1/355 Manukau Road Epsom, Auckland 1023 PO Box 26283 Epsom, Auckland 1344 T: 09 638 8414 E: hegley@acoustics.co.nz WAIKATO POWER PLANT SH31, KAWHIA ROAD OTOROHANGA ASSESSMENT OF NOISE EFFECTS Report No

More information

A review of the use of different noise prediction models for windfarms and the effects of meteorology

A review of the use of different noise prediction models for windfarms and the effects of meteorology A review of the use of different noise prediction models for windfarms and the effects of meteorology G. Parry ACCON UK Limited, Unit B, Fronds Park, Frouds Lane, Aldermaston, RG7 4LH Reading, UK graham.parry@accon-uk.com

More information

PROFESSIONAL OPINION ON THE NOISE IMPACT OF THE PROPOSED NEW LANDFILL SITE AT TUTUKA. April Report No 09/11/2 Rev 1. F le R Malherbe Pr Eng

PROFESSIONAL OPINION ON THE NOISE IMPACT OF THE PROPOSED NEW LANDFILL SITE AT TUTUKA. April Report No 09/11/2 Rev 1. F le R Malherbe Pr Eng PROFESSIONAL OPINION ON THE NOISE IMPACT OF THE PROPOSED NEW LANDFILL SITE AT TUTUKA April 2010 Report No 09/11/2 Rev 1 F le R Malherbe Pr Eng AC Tel: +27 12 803 0548 Fax: +27 12 803 8736 Cell: +27 82

More information

MT EMERALD WIND FARM Noise impact assessment Rp 001 R ML. 16 April 2014

MT EMERALD WIND FARM Noise impact assessment Rp 001 R ML. 16 April 2014 MT EMERALD WIND FARM Noise impact assessment Rp 001 R02 2012376ML 16 April 2014 6 Gipps Street Collingwood 3066 Victoria Australia T: +613 9416 1855 F: +613 9416 1231 A.C.N. 006 675403 www.marshallday.com

More information

Status: Rev: Comments Date: Author: Reviewer:

Status: Rev: Comments Date: Author: Reviewer: MB ASSESSMENT OF NOISE EFFECTS Rp 002 R02 2016907 3 May 2018 84 Symonds Street PO Box 5811 Wellesley Street Auckland 1141 New Zealand T: +64 9 379 7822 F: +64 9 309 3540 www.marshallday.com Project: MB

More information

PROPOSED PLAN CHANGE: ALEXANDER ROAD UPPER HUTT. Noise Assessment. Rp W. 27 July 2012

PROPOSED PLAN CHANGE: ALEXANDER ROAD UPPER HUTT. Noise Assessment. Rp W. 27 July 2012 PROPOSED PLAN CHANGE: ALEXANDER ROAD UPPER HUTT Noise Assessment Rp001 2012185W 27 July 2012 Level 2 5 Willeston Street PO Box 25442 Panama Street Wellington 6146 New Zealand T: +64 4 499 3016 F: +64 4

More information

Oldman 2 Wind Farm Limited

Oldman 2 Wind Farm Limited Decision 22706-D01-2017 Spring 2017 Comprehensive Sound Survey at Receptors R and S August 25, 2017 Alberta Utilities Commission Decision 22706-D01-2017 Proceeding 22706 Application 22706-A001 August 25,

More information

NOISE IMPACT ASSESSMENT FOR SITE PLAN APPROVAL 47 HAVELOCK STREET OTTAWA, ON. REVISED with ADDENDUM for ROOFTOP OUTDOOR LIVING AREA

NOISE IMPACT ASSESSMENT FOR SITE PLAN APPROVAL 47 HAVELOCK STREET OTTAWA, ON. REVISED with ADDENDUM for ROOFTOP OUTDOOR LIVING AREA NOISE IMPACT ASSESSMENT FOR SITE PLAN APPROVAL 47 HAVELOCK STREET OTTAWA, ON. REVISED with ADDENDUM for ROOFTOP OUTDOOR LIVING AREA REPORT PREPARED FOR SURFACE DEVELOPMENTS 61 FOREST HILL AVE. OTTAWA,

More information

MECHANICAL PLANT FOR COMMERCIAL BUILDINGS

MECHANICAL PLANT FOR COMMERCIAL BUILDINGS MECHANICAL PLANT FOR COMMERCIAL BUILDINGS Excessive noise from the operation of mechanical plant can disturb residents, disrupt sleep, interfere with normal daily activities and significantly impact on

More information

NOISE MODELING STUDY REPORT NO A ROARING BROOK WIND FARM PROJECT AND ENVIRONMENTAL IMPACT ASSESSMENT

NOISE MODELING STUDY REPORT NO A ROARING BROOK WIND FARM PROJECT AND ENVIRONMENTAL IMPACT ASSESSMENT 3862 Clifton Manor Place Suite B Haymarket, Virginia 20169 USA Phone: 703-753-1602 Fax: 703-753-1522 Website: www.hesslernoise.com REPORT NO. 1802-091507-A REV: A DATE OF ISSUE: OCTOBER 12, 2007 NOISE

More information

Monthly Noise Monitoring Assessment

Monthly Noise Monitoring Assessment Monthly Noise Monitoring Assessment Tomingley Gold Mine, December 2018 Prepared for: Tomingley Gold Operations Pty Limited December 2018 MAC160270RP28 Document Information Monthly Noise Monitoring Assessment

More information

Rumster Wind Energy Project

Rumster Wind Energy Project Rumster Wind Energy Project Report OSE3525 Appendix D Noise and Shadow Flicker Assessment Orkney Sustainable Energy Limited 6 North End Road Stromness Orkney KW16 3AG Telephone 01856850054 Facsimile 01856851199

More information

Environmental Noise Compliance Assessment Bass Point Quarry

Environmental Noise Compliance Assessment Bass Point Quarry P: 4421 4583 M: 0414 315 775 50 Junction Street, Nowra, NSW 2541 matthew@harwoodacsoutics.com.au www.harwoodacoustics.com.au ABN: 71634 997 937 Environmental Noise Compliance Assessment Bass Point Quarry

More information

CRANBOURNE LANDFILL. Environmental Noise Assessment. Rp ML. 10 May 2013

CRANBOURNE LANDFILL. Environmental Noise Assessment. Rp ML. 10 May 2013 CRANBOURNE LANDFILL Environmental Noise Assessment Rp 001 2012351ML 10 May 2013 4/46 Balfour St Chippendale NSW 2008 T: +612 9282 9422 Fax: +612 9281 3611 www.marshallday.com Project: CRANBOURNE LANDFILL

More information

Wind Farms Environmental Noise Guidelines

Wind Farms Environmental Noise Guidelines Wind Farms Environmental Noise Guidelines For further information please contact: Information Officer Environment Protection Authority GPO Box 2607 Adelaide SA 5001 Telephone: (08) 8204 2004 Facsimile:

More information

Assessment - Draft. Assessment - Draft. Ripley Valley Amex SUCE Development Stages ROL Phase

Assessment - Draft. Assessment - Draft. Ripley Valley Amex SUCE Development Stages ROL Phase Road Traffic Traffic Noise Noise Impact Impact Assessment - Draft Assessment - Draft Ripley Valley Amex SUCE Development Stages 33-37 ROL Phase Ripley Valley Amex SUCE Development Stages 33-37 ROL Phase

More information

Appendices. Acoustic Environment Assessment MAROOCHY SHIRE COUNCIL PLANNING SCHEME POLICY NO. 7. Contents ACOUSTIC ENVIRONMENT ASSESSMENT

Appendices. Acoustic Environment Assessment MAROOCHY SHIRE COUNCIL PLANNING SCHEME POLICY NO. 7. Contents ACOUSTIC ENVIRONMENT ASSESSMENT MAROOCHY SHIRE COUNCIL PLANNING SCHEME POLICY NO. 7 Acoustic Environment Assessment Contents 1 Introduction...188 1.1 Purpose...188 1.2 Scope...188 1.3 Definitions...188 1.4 Expertise Required to Prepare

More information

Assessment. Assessment. Ripley Valley Amex SUCE Development Stages ROL Phase. Ripley Valley Amex SUCE Development Stages ROL Phase

Assessment. Assessment. Ripley Valley Amex SUCE Development Stages ROL Phase. Ripley Valley Amex SUCE Development Stages ROL Phase Road Traffic Traffic Noise Noise Impact Impact Assessment Assessment Ripley Valley Amex SUCE Development Stages 15-19 ROL Phase Ripley Valley Amex SUCE Development Stages 15-19 ROL Phase A038_790400_02

More information

6.0. Noise and Vibration.

6.0. Noise and Vibration. 6.0 Noise and Vibration 6.0 Noise and Vibration 6.1 Introduction 6.2 Assessment Methodology 6.3 Noise Sensitive Receptors 6.4 Expected Maximum Noise Emissions 6.1 Introduction This section aims to assess

More information

Freight Rail Noise Policy and Practice

Freight Rail Noise Policy and Practice Freight and Logistics Council of Western Australia BULLETIN # 07 Introduction Bulletin No. 7 from the Freight and Logistics Council of Western Australia discusses recent research by the Council into freight

More information

APPENDIX 6.3-A Noise Modelling Year 2

APPENDIX 6.3-A Noise Modelling Year 2 ENVIRONMENTAL ASSESSMENT APPENDICES APPENDIX 6.3-A Noise Modelling Year 2 VE51988 Appendices 1.0 THE NOISE MAPPING MODEL The predicted changes to environmental sound levels from the proposed Project during

More information

Salem, Massachusetts

Salem, Massachusetts Salem, Massachusetts June 30, 2011 Prepared for: Meridian Associates Prepared by: Howard Quin Consulting LLC and Cavanaugh-Tocci Associates Contents 1 Introduction... 3 2 Noise Standards and Criteria...

More information

ENVIRONMENTAL NOISE CONTROL FOR SEMICONDUCTOR MANUFACTURING FACILITIES

ENVIRONMENTAL NOISE CONTROL FOR SEMICONDUCTOR MANUFACTURING FACILITIES Presented at Inter-Noise 99 The 1999 Congress and Exposition on Noise Control Engineering December 8, 1999, Fort Lauderdale, Florida ENVIRONMENTAL NOISE CONTROL FOR SEMICONDUCTOR MANUFACTURING FACILITIES

More information

Synergy Wind Pty Ltd PO Box 327 Balaclava VIC 3183

Synergy Wind Pty Ltd PO Box 327 Balaclava VIC 3183 ALBERTON WIND FARM NOISE ASSESSMENT Rp 001 R02 2015590ML 6 September 2017 6 Gipps Street Collingwood 3066 Victoria Australia T: +613 9416 1855 A.C.N. 006 675 403 www.marshallday.com Project: ALBERTON WIND

More information

8. Appendix F Acoustic Assessment

8. Appendix F Acoustic Assessment 8. Appendix F Acoustic Assessment HFT Ltd 06-Jun-2017 Assessment of Noise Effects Mixed Industrial Development at 28 Inlet Road, Takanini Mixed Industrial Development at 28 Inlet Road, Takanini Client:

More information

Noise Impact Assessment

Noise Impact Assessment Noise Impact Assessment December 2016 Prepared by SRL Technical Services Ltd Telephone +44(0)1787 247595 Website www.srltsl.com London, Birmingham, Manchester, Sudbury Quality Assurance Project Title Document

More information

APPENDIX 12 NOISE IMPACT ASSESSMENT USING HEALTH CANADA GUIDELINES

APPENDIX 12 NOISE IMPACT ASSESSMENT USING HEALTH CANADA GUIDELINES APPENDIX 12 NOISE IMPACT ASSESSMENT USING HEALTH CANADA GUIDELINES Suncor Energy Inc. - i - Noise Health Canada TABLE OF CONTENTS SECTION PAGE 1 INTRODUCTION... 1 2 ASSESSMENT APPROACH... 2 2.1 HEALTH

More information

Qualitative Noise Impact Evaluation for the Continuous Disposal of Ash at the Camden Power Station

Qualitative Noise Impact Evaluation for the Continuous Disposal of Ash at the Camden Power Station Project done on Behalf of Zitholele Consulting Qualitative Noise Impact Evaluation for the Continuous Disposal of Ash at the Camden Power Station Report No.: 12ZIT11 Revision 0 Date: 19 March 2013 Prepared

More information

MURRA WARRA WIND FARM PRELIMINARY ENVIRONMENTAL NOISE ASSESSMENT

MURRA WARRA WIND FARM PRELIMINARY ENVIRONMENTAL NOISE ASSESSMENT Sonus Pty Ltd 17 Ruthven Avenue ADELAIDE SA 5000 Phone: +61 8 8231 2100 www.sonus.com.au ABN: 67 882 843 130 Contact: Jason Turner Mobile: 0410 920 122 jturner@sonus.com.au MURRA WARRA WIND FARM PRELIMINARY

More information

No significant construction or operational vibration impacts are expected.

No significant construction or operational vibration impacts are expected. 8 NOISE AND VIBRATION 8.1 SUMMARY OF RESIDUAL IMPACTS impacts for the construction and operation of the proposed CCGT power plant development are expected as these will be mitigated through design and

More information

Noise Feasibility Study EMGO (North Oakville I) Ltd., Town of Oakville, Ontario

Noise Feasibility Study EMGO (North Oakville I) Ltd., Town of Oakville, Ontario Noise Feasibility Study EMGO (North Oakville I) Ltd., Town of Oakville, Ontario For Emgo (North Oakville I) Ltd. 2173 Turnberry Road Burlington, ON L7M 4P8 Prepared by Victor Garcia, BASc Reviewed by Sheeba

More information

LOTS 2 & 3 ANKETELL ROAD, ANKETELL SUBDIVISION ACOUSTIC ASSESSMENT FOR TERRANOVIS

LOTS 2 & 3 ANKETELL ROAD, ANKETELL SUBDIVISION ACOUSTIC ASSESSMENT FOR TERRANOVIS Rochdale Holdings Pty Ltd A.B.N. 85 009 049 067 trading as: HERRING STORER ACOUSTICS Suite 34, 11 Preston Street, Como, W.A. 6152 P.O. Box 219, Como, W.A. 6952 Telephone: (08) 9367 6200 Facsimile: (08)

More information

Environmental Noise Assessment 1020, 1024, 1028, 1032 & 1042 Sixth Line Oakville, ON

Environmental Noise Assessment 1020, 1024, 1028, 1032 & 1042 Sixth Line Oakville, ON Environmental Noise Assessment 1020, 1024, 1028, 1032 & 1042 Sixth Line Oakville, ON Novus Reference No. 16-0173 Version No. 1.0 (Final) September 30, 2016 NOVUS PROJECT TEAM: Specialist: Marcus Li, P.Eng.

More information

Appendix 4 Noise Report

Appendix 4 Noise Report Appendix 4 Noise Report aci Acoustical Consultants Inc. 5031 210 Street Edmonton, Alberta, Canada T6M 0A8 Phone: (780) 414-6373, Fax: (780) 414-6376 www.aciacoustical.com Environmental Noise Impact Assessment

More information

Lot 12 Honeywood Ave, Wandi Traffic Noise Assessment Report

Lot 12 Honeywood Ave, Wandi Traffic Noise Assessment Report Lot 12 Honeywood Ave, Wandi Traffic Noise Assessment Report Wandi Developments Pty Ltd c/- Terranovis 11 February 2014 Revision No. 1 Prepared by Andreas Lejholm Project Number: 25264-PER-N Ground Floor,

More information

Variations of sound from wind turbines during different weather conditions

Variations of sound from wind turbines during different weather conditions Variations of sound from wind turbines during different weather conditions Conny Larsson 1 Olof Öhlund 2 Department of Earth Sciences, Uppsala University, Villavägen 16, SE-752 36 Uppsala, Sweden Long-term

More information

Comparison of compliance results obtained from the various wind farm standards used in Australia

Comparison of compliance results obtained from the various wind farm standards used in Australia Paper Number 50, Proceedings of ACOUSTICS 2011 Comparison of compliance results obtained from the various wind farm standards used in Australia Jonathan Cooper (1), Tom Evans (1) and Luis Najera (2) (1)

More information

Wind Turbine Noise Assessment in Ontario

Wind Turbine Noise Assessment in Ontario Wind Turbine Noise Assessment in Ontario Jim Salmon York University ESS 5210 2013-11-26 (Tuesday) Toronto, Ontario, Canada Noise Assessment Sound Hz: measurement of frequency (tone) db: measurement of

More information

SELWYN PRIMARY SCHOOL, LONDON ENVIRONMENTAL NOISE SURVEY

SELWYN PRIMARY SCHOOL, LONDON ENVIRONMENTAL NOISE SURVEY 202 Uxbridge Road London W12 7JP Tel: +44(0)203 475 2280 Fax: +44(0)203 475 2281 info@clementacoustics.co.uk www.clementacoustics.co.uk SELWYN PRIMARY SCHOOL, LONDON ENVIRONMENTAL NOISE SURVEY Report 8991-ENS-03

More information

TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES APPENDIX B NOISE TABLE OF CONTENTS SECTION PAGE 1.1 INTRODUCTION...1 1.2 METHODS...1 1.2.1 Study Area Boundaries...1 1.2.2 Baseline Case...6 1.2.3 Facility Noise Modelling...7 1.2.4 Noise at 1.5 km From

More information

Assessment - Draft. Assessment - Draft. Ripley Valley Amex SUCE Development Stages 42A ROL Phase

Assessment - Draft. Assessment - Draft. Ripley Valley Amex SUCE Development Stages 42A ROL Phase Road Traffic Traffic Noise Noise Impact Impact Assessment - Draft Assessment - Draft Ripley Valley Amex SUCE Development Stages 42A ROL Phase Ripley Valley Amex SUCE Development Stages 42A ROL Phase A038_790147

More information

Noise Impact Assessment Dalveen Wind Farm Dalveen, QLD

Noise Impact Assessment Dalveen Wind Farm Dalveen, QLD Dalveen Wind Farm Dalveen, QLD Document No. SP0372-0, Revision 1 Prepared for: Muirlawn Pty Ltd PO Box 5816 West End QLD 4101 20 May 2013 DOCUMENT CONTROL PAGE SAVERY & ASSOCIATES PTY LTD Suite 4, The

More information

Planning. Local. 46 Planning

Planning. Local. 46 Planning Planning Planning is an important part of the task of urban noise management and can be viewed at two different levels: Global where the noise environment of a large area is continuously managed to prevent

More information

Roadway Traffic Noise Assessment Chapel Street. Ottawa, Ontario

Roadway Traffic Noise Assessment Chapel Street. Ottawa, Ontario Roadway Traffic Noise Assessment 151-153 Chapel Street Ottawa, Ontario REPORT: GWE14-064 Noise Prepared For: Brad Caco Sun Life Financial Center, East Tower 3250 Bloor Street West, Suite 1000 Toronto,

More information

EPA GUIDANCE NO. 8 ENVIRONMENTAL NOISE

EPA GUIDANCE NO. 8 ENVIRONMENTAL NOISE EPA GUIDANCE NO. 8 ENVIRONMENTAL NOISE Draft for public and stakeholder review Seminar Presented by Environmental Noise Management and SVT Engineering Consultants 25 June 2007 Overview Development of Guidance

More information

Noise Impact Assessment

Noise Impact Assessment APPENDIX C Noise Impact Assessment CBCL Limited Appendices NOISE IMPACT ASSESSMENT PUGWASH WIND FARM, NOVA SCOTIA Client Pugwash Wind Farm Inc. Contact Charles Demond Document No Issue B Status Classification

More information

ASSESSMENT OF HVAC NOISE IMPACTS FROM HALF MOON BAY CATHOLIC ELEMENTARY SCHOOL

ASSESSMENT OF HVAC NOISE IMPACTS FROM HALF MOON BAY CATHOLIC ELEMENTARY SCHOOL Ottawa, Ontario, Canada ASSESSMENT OF HVAC NOISE IMPACTS FROM HALF MOON BAY CATHOLIC ELEMENTARY SCHOOL Prepared for Prepared by Hugh Williamson Associates Inc. Postal Address: PO Box 74056, RPO Beechwood,

More information

100 Avenue Road, Swiss Cottage, London

100 Avenue Road, Swiss Cottage, London 100 Avenue Road, Swiss Cottage, London 296993-01(00) NOVEMBER 2017 RSK GENERAL NOTES Project No.: 296993-01(00) Title: 100 Avenue Road, Swiss Cottage, London - Client: Date: 30 th November 2017 Office:

More information

BS4142:2014 Assessment for Planning Application

BS4142:2014 Assessment for Planning Application Southbrook Farm, Sudbrook Peaking Power Generation Plant BS4142:2014 Assessment for Planning Application 20 th March 2018 inacoustic cymru Talbot Green Business Centre, 2 Talbot Green Business Park, Talbot

More information

R e p o r t th S e p t e m ber 2016

R e p o r t th S e p t e m ber 2016 N o ise Mon it o r ing R e p o r t L e g a c y W a y T u n n e l M o n i t o r i n g P o s t C o m m is s i o n ing T es t 2 V e n ti la t ion S t a c ks S e p tem b e r 2 0 1 6 R e p o r t 3557-2 2 9

More information

ACOUSTIC MODELING REPORT FOR THE DEVELOPMENT OF WIND ENERGY FACILITIES AT NAVSTA NEWPORT, RHODE ISLAND. March 2011

ACOUSTIC MODELING REPORT FOR THE DEVELOPMENT OF WIND ENERGY FACILITIES AT NAVSTA NEWPORT, RHODE ISLAND. March 2011 ACOUSTIC MODELING REPORT FOR THE DEVELOPMENT OF WIND ENERGY FACILITIES AT NAVSTA NEWPORT, RHODE ISLAND March 2011 ACOUSTIC MODELING REPORT FOR THE DEVELOPMENT OF WIND ENERGY FACILITIES AT NAVSTA NEWPORT,

More information

Burnt Hill Wind Development

Burnt Hill Wind Development Report OSE3581 Appendix D Noise and Shadow Flicker Assessment Environmental Health Studies: Noise and Shadow Flicker Assessment 1 Summary results 1.1 Wind turbines can create two types of environmental

More information

JONGENS KEET ASSOCIATES ACOUSTICAL ENGINEERING CONSULTANTS. Telephone: Facsimile:

JONGENS KEET ASSOCIATES ACOUSTICAL ENGINEERING CONSULTANTS. Telephone: Facsimile: JKA JONGENS KEET ASSOCIATES ACOUSTICAL ENGINEERING CONSULTANTS Telephone: 021 7945643 Facsimile: 021 7945643 email: jongens@yebo.co.za A.W.D. Jongens 8 Wingerd Avenue 7806 CONSTANTIA Tel/Fax: 021 794 5643

More information

Wind Turbine Noise, Infrasound and Noise Perception

Wind Turbine Noise, Infrasound and Noise Perception Wind Turbine Noise, Infrasound and Noise Perception Anthony L. Rogers, Ph.D. Renewable Energy Research Laboratory at Amherst January 18, 2006 www.ceere.org/rerl Overview Terminology Wind Turbine Noise

More information

PROPOSED CO-OPERATIVE SUPERMARKET, KNIGHTON

PROPOSED CO-OPERATIVE SUPERMARKET, KNIGHTON REPORT N O 70020648-001 PROPOSED CO-OPERATIVE SUPERMARKET, KNIGHTON NOISE IMPACT ASSESSMENT MAY 2016 PROPOSED CO-OPERATIVE SUPERMARKET, KNIGHTON NOISE IMPACT ASSESSMENT The Mid-Counties Co-Operative Final

More information

Acoustic Consulting Australia PtyLtd. I Consultants on Noise and Vibration P0 Box 332

Acoustic Consulting Australia PtyLtd. I Consultants on Noise and Vibration P0 Box 332 Pg 'P. Acoustic Consulting Australia PtyLtd. I Consultants on Noise and Vibration P0 Box 332 Heidelberg i#i..wr. David, u.,0 Victoria 3054 Phone 0412 375 234 Email: acausteblgpond.corn ABN 49 095 932 092

More information

REP Fotenn Bank Phase 1 Feasibility Noise Study with Building Component AmendmentPage 1 of 21

REP Fotenn Bank Phase 1 Feasibility Noise Study with Building Component AmendmentPage 1 of 21 REP Fotenn 890-900 Bank Phase 1 Feasibility Noise Study with Building Component AmendmentPage 1 of 21 2018-02-28 Emilie Coyle, M.Pl Planner Fotenn Planning + Design 223 McLeod St, Ottawa, ON K2P 0Z8 Office:

More information

Barrabool Hills Shopping Centre. Environmental Noise. Addressee: Lascorp Development Group (Aust) Pty Ltd

Barrabool Hills Shopping Centre. Environmental Noise. Addressee: Lascorp Development Group (Aust) Pty Ltd Project: Barrabool Hills Shopping Centre Subject: Environmental Noise Addressee: Lascorp Development Group (Aust) Pty Ltd Issued To: Rob Harris Date: 4 September 2012 Reference: 13021-1 Prepared by: David

More information

Stationary Noise Feasibility Assessment. 315 Chapel Street Ottawa, Ontario

Stationary Noise Feasibility Assessment. 315 Chapel Street Ottawa, Ontario Stationary Noise Feasibility Assessment 315 Chapel Street Ottawa, Ontario REPORT: GWE17 002 Stationary Noise Prepared For: Leanne Moussa Allsaints 10 Blackburn Avenue K1N 6P8 Ottawa, Ontario Prepared By:

More information

Proposed Revisions to. Wind Energy Development Guidelines Targeted Review in relation to Noise, Proximity and Shadow Flicker December 11 th 2013

Proposed Revisions to. Wind Energy Development Guidelines Targeted Review in relation to Noise, Proximity and Shadow Flicker December 11 th 2013 Proposed Revisions to Wind Energy Development Guidelines 2006 Targeted Review in relation to Noise, Proximity and Shadow Flicker December 11 th 2013 1 Contents Page Introduction 3 Revision to Noise sections

More information

Wind Law - - To replace 17, Noise Standards and Setbacks for Wind Energy Conversion

Wind Law - - To replace 17, Noise Standards and Setbacks for Wind Energy Conversion Wind Law - - To replace 17, Noise Standards and Setbacks for Wind Energy Conversion Systems in its entirety. 19 November 2010 NEW TITLE: 17, Noise Standards and Enforcement for Wind Energy Conversion Systems

More information

Additional information relevant to Section 7 is presented in Appendix D in Volume 2 of 3 of the EIS.

Additional information relevant to Section 7 is presented in Appendix D in Volume 2 of 3 of the EIS. 7. NOISE & VIBRATION Additional information relevant to Section 7 is presented in Appendix D in Volume 2 of 3 of the EIS. 7.1 RECEIVING ENVIRONMENT 7.1.1 Monitoring Continuous noise monitoring was undertaken

More information

Noise Assessment Report

Noise Assessment Report Noise Assessment Report 176 Greenfield Avenue Prepared for: TC United Group Prepared by: Stantec Consulting Ltd. February 8, 2016 NOISE ASSESSMENT REPORT Introduction February 8, 2016 Table of Contents

More information

Decibell Consulting pty Ltd

Decibell Consulting pty Ltd db Decibell Consulting pty Ltd Aspire 16-66 Wesley Rd, Griffin REVISED ENVIRONMENTAL NOISE IMPACT REPORT Prepared for Fairmont Group 23 rd January 2019 Decibell Report No. 1901251 Decibell Consulting Pty

More information

Noise Feasibility Study Proposed Hospice 2050 University Avenue East, Waterloo, Ontario

Noise Feasibility Study Proposed Hospice 2050 University Avenue East, Waterloo, Ontario Noise Feasibility Study Proposed Hospice 2050 University Avenue East, Waterloo, Ontario Prepared for: Hospice of Waterloo Region 298 Lawrence Avenue Kitchener, ON N2M 1Y4 Prepared by Sheeba Paul, MEng,

More information

EDINBURGH TRAM LINES ONE AND TWO

EDINBURGH TRAM LINES ONE AND TWO EDINBURGH TRAM LINES ONE AND TWO NOISE AND VIBRATION POLICY MARCH 2006 1 INTRODUCTION This policy statement sets out the approach the promoter proposes to adopt to mitigate noise from the operation of

More information

442 CHELTENHAM ROAD KEYSBOROUGH. Noise Control Considerations. Prepared for Bridport Property Group Level 1, 170 Bridport Street, Albert Park VIC 3206

442 CHELTENHAM ROAD KEYSBOROUGH. Noise Control Considerations. Prepared for Bridport Property Group Level 1, 170 Bridport Street, Albert Park VIC 3206 442 CHELTENHAM ROAD KEYSBOROUGH Noise Control Considerations Prepared for Bridport Property Group Level 1, 170 Bridport Street, Albert Park VIC 3206 Ref. 11649-1ng.docx 22 December 2014 TABLE OF CONTENTS

More information

Status: Rev: Comments Date: Author: Reviewer:

Status: Rev: Comments Date: Author: Reviewer: FREE RANGE BROILER FARM, ARAPOHUE ASSESSMENT OF ENVIRONMENTAL EFFECTS Rp 001 R02 20170847 18 September 2017 84 Symonds Street PO Box 5811 Wellesley Street Auckland 1141 New Zealand T: +64 9 379 7822 F:

More information

Environmental Noise Assessment

Environmental Noise Assessment July to September 2014 Rev 0 (Final) Report Details - July to September 2014 Filename: Job #: J0140003 Folder #: F13130 Revision: 0 (Final) Date: Prepared For Clark Potter, Senior Environmental Advisor

More information

Environmental Noise Impact Assessment. Crag Digital Energy Centre

Environmental Noise Impact Assessment. Crag Digital Energy Centre 4 Turlough Gardens, Fairview, Dublin 3 Phone : +353 (0)1 8376693 www.acoustic-designs.com Environmental Noise Impact Assessment Crag Digital Energy Centre Author : Dr. Peter Hill Date : September 2017

More information

9 October Town of Medway 155 Village Street Medway, MA Chair, Medway Board of Selectmen

9 October Town of Medway 155 Village Street Medway, MA Chair, Medway Board of Selectmen Town of Medway 155 Village Street Medway, MA 02053 Attention: Subject: John Foresto Chair, Medway Board of Selectmen Acoustical Consulting Services Application Review for Two 100 MWe Combustion Turbine

More information

CARRYING OUT NOISE ASSESSMENTS FOR PROPOSED SUPERMARKET DEVELOPMENTS

CARRYING OUT NOISE ASSESSMENTS FOR PROPOSED SUPERMARKET DEVELOPMENTS Acoustics 2008 Geelong, Victoria, Australia 24 to 26 November 2008 Acoustics and Sustainability: How should acoustics adapt to meet future demands? CARRYING OUT NOISE ASSESSMENTS FOR PROPOSED SUPERMARKET

More information

STATEMENT OF EVIDENCE OF CURT ROBINSON ON BEHALF THE AUCKLAND UTILITY OPERATORS GROUP

STATEMENT OF EVIDENCE OF CURT ROBINSON ON BEHALF THE AUCKLAND UTILITY OPERATORS GROUP BEFORE THE AUCKLAND UNITARY PLAN INDEPENDENT HEARINGS PANEL IN THE MATTER of the Resource Management Act 1991 and the Local Government (Auckland Transitional Provisions) Act 2010 AND IN THE MATTER of the

More information

Stationary Noise Feasibility Assessment. 315 Chapel Street Ottawa, Ontario

Stationary Noise Feasibility Assessment. 315 Chapel Street Ottawa, Ontario Stationary Noise Feasibility Assessment 315 Chapel Street Ottawa, Ontario REPORT: GWE17-002 - Stationary Noise Prepared For: Leanne Moussa Allsaints 10 Blackburn Avenue K1N 6P8 Ottawa, Ontario Prepared

More information

NOISE IMPACT ASSESSMENT FOR SITE PLAN APPROVAL 12 HAMILTON AVENUE NORTH OTTAWA, ON.

NOISE IMPACT ASSESSMENT FOR SITE PLAN APPROVAL 12 HAMILTON AVENUE NORTH OTTAWA, ON. NOISE IMPACT ASSESSMENT FOR SITE PLAN APPROVAL 12 HAMILTON AVENUE NORTH OTTAWA, ON. REPORT PREPARED FOR SURFACE DEVELOPMENTS 61 FOREST HILL AVE. OTTAWA, ON, K2C 1P7 September 15, 2016 16419 1 NOISE IMPACT

More information

ACOUSTIC STUDY OF THE SUNY CANTON WIND TURBINE CANTON, NEW YORK. June 2013

ACOUSTIC STUDY OF THE SUNY CANTON WIND TURBINE CANTON, NEW YORK. June 2013 ACOUSTIC STUDY OF THE SUNY CANTON WIND TURBINE CANTON, NEW YORK June 2013 ACOUSTIC STUDY OF THE SUNY CANTON WIND TURBINE CANTON, NEW YORK Prepared for: Sustainable Energy Developments, Inc. 317 Route 104

More information

Noise Impact Assessment

Noise Impact Assessment Noise Impact Assessment Green Oil Company Ltd. Botswana LSD 13-7-48-9 W5M Prepared For Mr. John Q. Public, P.Eng. Green Oil Company Ltd. Prepared By Mr. James Farquharson, CET Mr. Don South, RET Ms. Turi

More information

Skeabrae Wind Energy Project

Skeabrae Wind Energy Project Skeabrae Document OSE/3526 March 2013 Skeabrae Wind Energy Project Noise and Shadow Impact Revision 3: V29 225kW wind turbine Richard Gauld IEng MInstMC BSc(Hons) Dip. DesInn Dip. GeoSci 1 Skeabrae Wind

More information

Acoustical Analysis of the Horse Creek Wind Project

Acoustical Analysis of the Horse Creek Wind Project MEMORANDUM Acoustical Analysis of the Horse Creek Wind Project TO: FROM: Horse Creek Project Team Mark Bastasch/CH2M HILL DATE: January 27, 2011 Summary This memorandum presents the predicted sound levels

More information

9. NOISE AND VIBRATION

9. NOISE AND VIBRATION 9. NOISE AND VIBRATION 9.1 Introduction 9.1.1 This Chapter details the existing baseline noise and vibration levels together with assessments of the suitability of the site for residential and commercial

More information

Synergy Wind Pty Ltd PO Box 327 Balaclava VIC 3183

Synergy Wind Pty Ltd PO Box 327 Balaclava VIC 3183 ALBERTON WIND FARM NOISE ASSESSMENT Rp 002 R02 2015590ML 19 April 2018 6 Gipps Street Collingwood 3066 Victoria Australia T: +613 9416 1855 A.C.N. 006 675 403 www.marshallday.com Project: ALBERTON WIND

More information

MEASUREMENT AND LEVEL OF INFRASOUND FROM WIND FARMS AND OTHER SOURCES

MEASUREMENT AND LEVEL OF INFRASOUND FROM WIND FARMS AND OTHER SOURCES MEASUREMENT AND LEVEL OF INFRASOUND FROM WIND FARMS AND OTHER SOURCES Chris Turnbull 1, Jason Turner 1 and Daniel Walsh 2 1 Sonus Pty Ltd, 17 Ruthven Avenue, Adelaide, South Australia 5000 2 Pacific Hydro

More information

3.5.1 Outdoor Living Areas (OLAs) Indoor Sound Levels... 8

3.5.1 Outdoor Living Areas (OLAs) Indoor Sound Levels... 8 RWDI was retained by Manor Park Management to conduct a traffic noise feasibility study as part of the Site Plan Approval (SPA) for the proposed development, to be located at the northwest corner of Vanier

More information

Environmental Noise Monitoring. Hanson Quarry Wagga Wagga, NSW. October 2012

Environmental Noise Monitoring. Hanson Quarry Wagga Wagga, NSW. October 2012 Environmental Noise Monitoring Hanson Quarry Wagga Wagga, NSW October 2012 Contents 1. INTRODUCTION... 3 2. UNATTENDED NOISE MONITORING... 3 3. EXISTING BACKGROUND NOISE LEVELS... 5 4. EXISTING AMBIENT

More information

NOISE IMPACT ASSESSMENT PROTOCOL. Number Three Wind Farm Lewis County, New York. Case 16-F-0328

NOISE IMPACT ASSESSMENT PROTOCOL. Number Three Wind Farm Lewis County, New York. Case 16-F-0328 NOISE IMPACT ASSESSMENT PROTOCOL Number Three Wind Farm Lewis County, New York Case 16-F-0328 October 2016 CONTENTS 1 Background... 3 2 Noise-Sensitive Receptors... 4 3 Ambient Noise Assessment... 5 3.1

More information

APPENDIX G NOISE ASSESSMENT

APPENDIX G NOISE ASSESSMENT Environmental Impact Statement Beryl Solar Farm APPENDIX G NOISE G.1 NOISE REPORT G.2 DRAFT CONSTRUCTION NOISE MANAGEMENT PLAN Beryl Solar Farm 16 347 Final V1 G i Acoustics Vibration Structural Dynamics

More information

Proceedings of Meetings on Acoustics

Proceedings of Meetings on Acoustics Proceedings of Meetings on Acoustics Volume 19, 2013 http://acousticalsociety.org/ ICA 2013 Montreal Montreal, Canada 2-7 June 2013 Noise Session 3aNSa: Wind Turbine Noise I 3aNSa2. Development of a real

More information

Mann Avenue Development 87 Mann Avenue Noise Control Study

Mann Avenue Development 87 Mann Avenue Noise Control Study Mann Avenue Development 87 Mann Avenue Noise Control Study Prepared By: NOVATECH ENGINEERING CONSULTANTS LTD. Suite 200, 240 Michael Cowpland Drive Ottawa, Ontario K2M 1P6 August 13, 2013 Novatech File:

More information

APPENDIX 8. Noise Impact Assessment

APPENDIX 8. Noise Impact Assessment APPENDIX 8 Noise Impact Assessment Orica Australia Pty Limited Noise Impact Assessment for Proposed Ammonium Nitrate Emulsion Production Facility and Continued Operation of Orica Mining Services Technology

More information

Kamperman & James Nine-page summary edition Page 1 of 9

Kamperman & James Nine-page summary edition Page 1 of 9 Kamperman & James Nine-page summary 11-2-08 edition Page 1 of 9 Why Noise Criteria Are Necessary for Proper Siting of Wind Turbines Date: November 02, 2008 By: George W. Kamperman, INCE Bd. Cert. Emeritus

More information

Noise Analysis for Latitude II City of Escondido, California

Noise Analysis for Latitude II City of Escondido, California Noise Analysis for Latitude II City of Escondido, California Project #560401-0100b June 23, 2015 Prepared For: NCA Developments 14 Corporate Plaza, Suite 100 Laguna Hills, CA 92660 Prepared By: Matt B.

More information

8 Noise and Vibration

8 Noise and Vibration 8 Noise and Vibration 8.1 Introduction This chapter of the EIS assesses the potential noise and vibration impact of the Proposed Project on the baseline environment. The potential noise impact due to the

More information