COMPANY PRODUCT PORTFOLIO

Size: px
Start display at page:

Download "COMPANY PRODUCT PORTFOLIO"

Transcription

1 COMPANY PRODUCT PORTFOLIO

2 We represent: & Gas Alarm Marketing Pvt. Ltd, Jaipur

3 1. MSR Electronic, Germany: Our Principals: For Toxic, Flammable Gases for Safe, Hazardous Application ( Zone 1, Zone 2, Group I, II A, IIB, IIC) a. Analog and Digital Gas Sensors b. Analog and Digital Transmitter c. Controllers 2. Jola, Germany: a. Level Detectors, b. Continuous Level Monitoring, c. Leakage and Spill Detectors d. Moisture Detectors 3. Fischer, Germany: a. Temperature, b. Pressure, c. Differential Pressure, d. Level, e. Portables

4 4. Kimo, France: a. Pressure, b. Flow Meter, c. Flow Velocity, d. Temperature, e. Humidity, f. Data logger, g. Solarimeters 5. Greisinger, Germany: a. Portables, b. Sound Level Sensor, c. Humidity, d. Temperature, e. Oxygen, f. ph, g. Climate, h. Material Moisture, i. Transmitter, j. Datalogger, k. Flow 6. Sperian (Bio-system), USA: a. Portable Gas detectors / monitors, b. Hearing Protection, c. Respiratory Protection, d. Eye Protection, e. Body protection suits 7. Alre, Germany: a. Temperature, b. Climate Control, c. Humidity, d. Air Flow, e. Pressure, f. Conductivity,

5 g. Dissolved Oxygen 8. Beck Sensor, Germany: a. Pressure Switch, b. Differential Pressure Switch, c. Transmitter 9. MSR Traffic, Germany: a. Magnetic Sensor, b. Traffic Controller, c. Parking Solutions. 10. Frakta (Joventa), Germany: a. Actuators, b. Damper Actuators, c. Smoke Damper Actuators, d. Fire Damper Actuators, e. Valve Actuators, Valves 11. Madas, Italy: a. Valve, b. Solenoid Valves, c. Motorized Valves for Gas, Oil, Naphtha, Gas d. Filters

6 MSR Electronic, Germany: Gas Sensor, Detector, Transmitter & Controller For Toxic, Flammable Gases For Safe, Hazardous Application (Zone 1, Zone 2, Group I, II A, IIB, IIC) Toxic gases, Flammable / Combustible gases Acetic Acid Ethylene / C2H4 JP8 Ozone Acetone Ethylene Oxide LPG Petrol Vapors Acetylene Fluorine / F2 Mercaptan / (Thiols)/(-SH) Phosphine Ammonia Formaldehyde / CH2O Methane Propane Benzene Hydrazine / N2H4 Methanol Propyl Alcohol Carbon Dioxide / CO2 Hydrogen / H2 n-butane Propylene / Propene Carbon Monoxide / Hydrogen Chloride n-heptane Silane CO Chlorine / Cl2 Hydrogen Cyanide n-hexane Styrene Chlorine Dioxide / Hydrogen Fluoride Nitrogen Dioxide / Sulfur Hexafluoride / ClO2 NO2 SF6 Cyclopentane Hydrogen Sulphide Nitrogen Oxide / Sulphur Dioxide / SO2 NO Dinitrogen Oxide / Iso Butane Nitrogen Tetrahydrothiophene N2O Trifluoride Ethane / C2H6 Iso Butyl Alcohol n-octane Toluene Ethyl Acetate Iso Pentane nonane Trimethyl Amine Ethyl Alcohol Iso Propanol Alcohol n-pentane Trimethyl Benzene Ethyl Mercaptan Iso Propyl Alcohol Oxygen Xylene Carbon Dichloride Methyl Ethyl Ketone / Oxide / Phosgene MEK / C4H8O Refrigerant / Freon R134a, R22, R401a, R401b, R402a, R402b, R407c, R408a, R409a, R410a, R411a, R416a, R507 Air Quality / Volatile Organic Compound / VOC + CO2

7 Application Areas: MSR Electronic, Germany: Garages and Loading Bays (CO, NO, NO 2, LPG(propane) Laboratories (Combustible Gases, CO 2, O 2 ) Cooling systems (Ammonia - NH 3, Freons, CO 2 ) Heating Systems (Methane - Natural Gas CH 4 ) Offices and Production Areas (CO 2 /VOC, O 2 ) Swimming Pools (Cl 2, O 3 ) Wine Cellars (CO 2, O 2 ) Battery Charging Areas (H 2 ) Vehicle Repair Shops (Combustible Gases, CO, NO, NO 2, LPG (propane), SO 2 ) Waste Water facilities (Combustible Gases, NH 3 Ammonia, H 2 S, SO 2 ) Pumping Station ((Combustible Gases, NH 3 Ammonia, H 2 S, SO 2, Cl 2, O 3 )) Water Treatment Plants (H 2 S, SO 2, Cl 2, O 3 ) Operating Theatres (N 2 O, CH 2 O Formaldehyde)

8 MSR Electronic, Germany: Application Areas (Contd ) High Voltage Substations (SF6 Gas) Jet Fans and Exhaust Fans in underground Garages (CO, LPG, NOx) Biogas Plants ((Combustible Gases, Hydrogen Sulphide (H 2 S))

9 Floating Switches and Immersion Probes for Normal and Potential Explosive atmospheres in categories zone 0, 1 and 2 Float Switches for Normal and for Potential Explosive atmospheres in categories zone 0, 1 and 2 Immersion Probes type TSR for Normal and Potential Explosive Atmospheres Immersion Probes type NTR

10 Continuous Level Measurement (Float Method) Capacitive Level Controllers Leakage Detector Lekstar (Conductive) for Normal and Potential Explosive Atmospheres in categories zone 0, 1 and 2 Leakage Detector Lekmaster (Conductive) for Normal and Potential Explosive Atmospheres in categories zone 0, 1 and 2

11 Leakage Detector - Lekwatcher (Capacitive or Conductive) for Seperated Extra Low Voltage (SELV) or Protected Extra Low Voltage (PELV). For connection to a PLC or DDC unit, a small controller, a fieldbus connector or a network connector Leakage Detector - Liqui-Switch (Capacitive) are primarily designed for the detection of leakage of nonconductive liquids but can also be used for the detection of conductive liquids. Leakage Detector - L-Pointer (Capacitive) Detection of Moisture - Cooling Ceiling Controller type FTS for survelliance of server rooms, clean rooms, and storage rooms in Data Centres and Telecom Centres

12 Measurement Product Media Remark Pressure Guage, Transmitter, Switch Air, Gas, Liquid, Corrosive Also in EX Version Differential Pressure Guage, Transmitter, Switch Air, Gas, Liquid, Corrosive Also in EX Version Temperature Thermocouple, Switch, Transmitter Air, Gas, Liquid, Corrosive Also in EX Version Control Valve Air, Gas, Liquid, Corrosive Also in EX Version Level Switch, Transmitter, Indicator Air, Gas, Liquid, Corrosive Also in EX Version Flow Monitor Switch, Transmitter Aggressive Media Also in EX Version Applications: Biogas Plants Biogas as a renewable energy source has become more and more relevant for electrical power and heat generation. Reasons are the positive influence for the environment and the opportunity for agricultural or public operators of biogas generation plants to sell the energy or to utilize it for self purposes. For various applications in biogas plants FISCHER offers a range of well fitting and accurate devices. A selection is listed below: Gas pressure in fermenter (ME50) Liquid level (continous) in fermenter (ME11 or ME12) Liquid level (switch) in fermenter (NS01) Pump pressure monitoring (MS12) Temperature measuring (TW30)

13 Clean room FISCHER measuring instruments for use in clean room and laboratory applications as well as ventilation systems have been successfully deployed for a good number of years to reliably ensure the best possible environments in the production of chemical, pharmaceutical, semiconductor and photovoltaic products as well as in industry in general. Pressure, differential pressure, flow rate temperature and moisture are examples of the quantities measured

14 Portable Instruments Anemometer Flow Meters Air Quality Hygrometers Parameter Measured Vane Velocity, Air velocity, Airflow, Temperature Simultaneous display of air flow and temperature. Measurement of air delivery or exhaust Measurement range : 85 to 4000 m3/h Air Quality (CO, CO2), Climatic conditions, Temperature, Hygrometry. Memory: up to 8000 measurements points. For Ambience: Humidity : 5 to 95 %HR Temperature : -20 to +80 C Dew point : -40 to +80 Ctd Memory: up to 8000 measurements points. Pin Moisture Meter for Materials: Softwood : from 10 to 93.7 % Hardwood : from 8 to 78.5 % Concrete and plaster : from 1 to 2.5% Bricks : from 0 to 22.9 % Luxmeters from 0,1 to lux (from 0,01 to fc).

15 Micromanometers for Gas network sealing Pressure, differential pressure, manual autocalibration, Hold function, min/max. values. Measuring Ranges: 0 to ±130 mbar., 0 to ±1000 Pa, 0 to ±1000 mmh2o, 0 to ±500 mbar, 0 to ±2000 mbar, 0 to ±1000 Pa and from 2 to 40 m/s Solarimeters Sound level meters Tachometers Temperature Probe Thermometers Measurement and spot check of solar power (W/m2). Sound-pressure level, Time averaged or equivalent continuous sound pressure level. Measuring range : db Resolution : 0.1 db Optical or contact tachometry to tr/min - 30 to tr/min PT100, PT1000, Wire Temperature Probe, RTD Sensor, Surface contact wire temperature probe, Penetration probe with cable, T handle temperature probe, and many more Infrared, Remote Probe, Contact

16 ToxiproRange: Single-Gas Detector Measures O 2, CO, H 2 S, SO 2, NH 3 (Ammonia), Cl 2 (Chlorine), ClO 2 (Chlorine Dioxide), NO 2, HCN (Hydrogen Cynide), PH 3 (Phosphine) Mighty Tox: 90 day Disposable Single Sensor Gas Detector CO (35 to 100 ppm) CO (25 to 100 ppm) H 2 S (10 to 20 ppm) Multipro Range: Multi-Gas Detector Combustible Gases LEL + O 2 Combustible Gases LEL + O 2 + CO Combustible Gases LEL + O 2 + H 2 S Combustible Gases LEL + O 2 + CO + H 2 S Cannonball3 Continuous Sample Draw Multi-Gas Sensors For more details please visit our website