ACO Building Drainage

Size: px
Start display at page:

Download "ACO Building Drainage"

Transcription

1 ACO Building Drainage Backflow systems Backflow systems 33 Stop that backflow ACO backflow stops and lifting plant

2 Contents Background What causes backflow?... 3 Liability aspects... 3 The backflow level... 4 Installation principles and type classification... 5 Selection criteria for backflow safety valves... 6 Product line Cellar drain with backflow stop... 8 Type 2 backflow stop with shaft system Type 2 backflow stop for unenclosed pipes Type 3F black water automatic backflow stop with shaft system Type 3F black water automatic backflow stop for unenclosed pipes Type 0/1 backflow stops and cleaning pipes Optional components and accessories for backflow stops Mini lifting plant for wastewater free of faeces (underground) Mini lifting plant for wastewater free of faeces (above-floor) Lifting plant for wastewater containing faeces (mono) Lifting plant for wastewater containing faeces (duo) Pump station for wastewater containing faeces (mono) Pump station for wastewater containing faeces (duo)...30

3 Background What causes backflow? Wastewater can backflow into buildings whenever wastewater can no longer drain off optimally into the public sewers. The dimensioning of drainage installations today takes into consideration economic aspects and selfcleaning effects based on average rainfall events. However, heavy rainfall which exceeds the reference rainfall level can also occur. This means that the drainage installations can be overloaded at any time. In addition to periods of heavy rainfall, wastewater can also be prevented from draining off as quickly as required by unwanted reductions in pipe cross sections caused by deposits or blockages in sewer pipes, not to mention cracked pipes, pump failures in public sewers, and floods all can lead to sewage backflowing into a building. Levels are rising The flood on the River Oder in 1997, the Whitsun flood, the Flood of the millennium in 2002 on the Elbe and its tributaries, the major flooding in the Alps in 2005, and the extraordinary amount of snow in East Bavaria in February 2006 all point in one direction: extreme floods and heavy rain and snow falls are increasing across the whole of Europe. And they will become even more frequent in future. Flooding is basically a combination of two factors: water input and surface area. The first has increased: more heavy rainfall. The second has decreased: less unpaved and unbuilt-up areas. Paradoxically, the construction of flood prevention dikes on rivers has already increased the frequency of flooding. Scientists at the Max Planck Institute for Meteorology have observed a long term trend since the middle of the 70s of an increase in flood events affecting numerous rivers in west and south Germany and neighbouring countries. Even if these rivers do no break their banks, there is always a risk that sudden heavy rainfall can affect already overloaded sewers which are often only designed to handle average rainfall events. If the capacity of the sewer shafts is exceeded, wastewater follows the natural law of communicating pipes: it flows back into buildings. To prevent backflow, drainage installations below the backflow level have to be properly protected. 3 Local authorities are not liable for extraordinary floods or rainfall Home owners can no longer rely on the public sewers during extreme rainfall events. If water flows out of sewers during floods of the century, and causes damage to private homes, local authorities cannot be held liable according to the decision handed down by the German Federal Court of Justice (BGH) in Karlsruhe. Local authorities can claim force majeure under such circumstances. Although local authorities are responsible for the safe operation of the sewer system and are responsible for any damage caused during normal conditions, this no longer applies to completely unusual and rare disastrous rainfall, according to the BGH. Their justification is that liability for risks associated with pipe networks are limited by the economic strength of the local authorities. Extra costs for wider pipes have to stay within reasonable proportion to the additional protection provided by such measures. No fixed limit has been defined. It is clear however that local authorities no longer have to dimension their systems to cope with rain which occurs more rarely than every 100 years. This decision handed down in May 2004 strengthens the hand of local authorities who stipulate that landowners bear sole responsibility for protecting their property against backflow.

4 Background Backflow level Backflow level 4 The backflow level is the highest level (water level) to which wastewater can rise in a drainage installation. The backflow level is defined by the local authority (local bylaws). In the absence of any specific definition, the backflow level is usually taken as the level of the road above the sewer connections. All drainage installations below this level are at risk of backflow and should therefore be protected by implementing the appropriate measures.

5 Background Installation principles for backflow safety valves Incorrect Correct Drainage installations which lie above the backflow level (figure left) must not be connected to a backflow safety valve (lifting plant or backflow stop). This is because it would prevent wastewater draining off properly from installations above the backflow level during a backflow situation. According to the principle of communicating pipes, the wastewater would first flow up out of the deepest lying drains below the backflow level and flood the cellar. This is why all drainage installations installed above the backflow level must be connected to the sewer downstream of the backflow stops (figure right). During a backflow event, the down pipe will not fill higher than the level of the street, and the backflow stop prevents the wastewater backing up into deeper lying drainage installations instead it forces it to rise up through the manhole cover of the sewers. Type classification of backflow stops pursuant to EN Type Installation Automatic seal Emergency seal Area of application 0 Horizontal pipe 1 0 rain water installations 1 Horizontal pipe 1 1* rain water installations 2 Horizontal pipe 2 1* rain water installations/ wastewater free of faeces 3 Horizontal pipe 1 (pneumatic 1 wastewater free of faeces, wasteor electric) water containing faeces (designated F ) 4 Fitted in floor drains 1 1* wastewater free of faeces 5 Fitted in floor drains 2 1* wastewater free of faeces 5 * Emergency seal can be combined with an automatic seal. The use of different types is regulated by national law. The following table defines the specific authorisations applying to Germany, Austria and Switzerland. Country Differences Germany Austria Switzerland Types 2, 3 and 5 are authorised for wastewater free of faeces. Only Type 3 with designation F can be used for wastewater containing faeces. Types 0 to 5 are authorised for use with wastewater free of faeces. Only Type 3 can be used for wastewater con taining faeces. Backflow stops can only be used subject to prior case-by-case authorisation.

6 Which backflow safety valve is best for which application? Wastewater type Wastewater outflow Down gradient into the sewers No gradient to the sewers Wastewater free of faeces ACO JUNIOR Cellar drain with Type 5 backflow stop ACO SINKAMAT-K Underground (top) or above ground (below) lifting plant for wastewater free of faeces 6 ACO TRIPLEX-K Backflow stop for continuous pipe Type 2 Wastewater containing faeces ACO QUATRIX-K Backflow stop for continuous pipes Type 3F ACO MULI-STAR mono or duo Lifting plant for wastewater containing faeces

7 The benefits of ACO TRIPLEX-K backflow safety valves and QUATRIX-K using the shaft system Extensions for deeper installation If a backflow stop has to be installed at a much deeper level for structural reasons, it is easy to convert the ACO backflow safety valve shaft systems with the optional extensions. It is also easy to manually put together several extensions if required. Sealing flange for pressurised water If the floor plate needs to be protected against pressurised water, it is possible to equip the shaft system with an optional sealing flange. This flange provides reliable protection to keep the soil moisture out of the cellar. The height of the flange is infinitely adjustable for easy adaptation to the level of the floor plate. Adjustment to the tile pattern and floor level The top section for load class K3 is infinitely height adjustable and tiltable. This allows the cover to be perfectly adjusted to the floor height and the tile pattern. A specially adapted locking system also prevents small children from removing the cover. 7 Multi-option cover to suit customer s requirements Use either side of the cover as required. The uniform side is a plastic cover. If tiles are laid in the installation room, turn the cover round and use the side which is recessed to accommodate the matching tiles.

8 The ACO JUNIOR cellar drain with backflow stop Awarded the innovation prize at BAU 2007 in Munich The ACO JUNIOR cellar drain with backflow stop is a Type 5 backflow stop in accordance with EN Because of its compact dimensions, this cellar drain is ideal for refurbishing cellars where the drainage systems are being upgraded by installing a backflow stop in one of the old drains. The ACO JUNIOR cellar drain with backflow stop has two flaps including an emergency seal. It is installed in the floor plate. Wastewater enters the drain via the grating. It is also possible to connect drainage installations to the drain, such as showers, washing machines or sinks lying beneath the backflow level, by adding a DN 50 inlet to the drain on site. During normal operating conditions, the flaps hang loose. The force of flowing wastewater pushes open the flap in the flow direction to drain the wastewater in the direction of the sewer. If there is back- flow, the wastewater backing up from the sewer flows against the normal flow direction and comes into contact with the outer backflow flap. This prevents wastewater from the sewers from flowing back into the building. The second flap is an extra safety feature to ensure that the backflow stop functions even when the first flap fails to close properly because of the presence of dirt, etc. The emergency seal integrated into the second flap provides additional security and can be operated manually. Note that when the emergency seal is locked in position, it also prevents wastewater generated in the building from flowing into the sewer! It is therefore very important that this emergency seal is reopened again immediately after returning to the building, e.g. after a holiday. 8 Product benefits Compact dimensions ideal for refurbishment No tools required to assemble and dismantle the sludge bucket and backflow device Rotatable top section for optimal adjustment to the tile pattern Extensions available for flexible adjustment to deeper installation positions Installation example ACO JUNIOR cellar drain with backflow stop DN 100 Type 5 pursuant to EN ACO JUNIOR Kellerablauf mit Rückstauverschluss, DN 100 Typ 5 nach DIN EN 13564

9 Article description ACO JUNIOR cellar drain with backflow stop, DN 100 Type 5 pursuant to EN 13564, Made of plastic with removable sludge bucket and odour trap, 60 mm water trap. Shut off unit with two backflow flaps and a manually lockable emergency seal, top section made of plastic with frame dimensions 197 x 197 m and grey grating class K3. Outlet socket DN 100 with 1.5º socket slope for connection to plastic pipes pursuant to DIN and DIN Drain performance: 1.6 l/s Weight: approx. 1.2 kg Article Article No. DN ACO JUNIOR Inlet socket Extension,, Height 130 mm ACO maintenance kit x ,

10 New! ACO TRIPLEX-K-2 double backflow stop with shaft system The ACO TRIPLEX-K-2 backflow stop is a Type 2 backflow safety valve pursuant to EN This product has been specially designed for installation in floor plates. The backflow stop can be equipped with a sealing flange against pressurised water. The ACO TRIPLEX-K-2 is specified for use with wastewater free of faeces. It must only be connected to drainage installations generating wastewater free of faeces, e.g. floor drains, showers or washing machines located below the backflow level. During normal operating conditions, the flaps hang loose. The force of flowing wastewater pushes open the flap in the flow direction to drain the wastewater in the direction of the sewer. If there is backflow, the wastewater backing up from the sewer flows against the normal flow direction and comes into contact with the outer backflow flap. This prevents wastewater from the sewers from flowing back into the building. The second flap is an extra safety feature to ensure that the backflow stop functions even when the first flap fails to close properly because of the presence of dirt, etc. The ACO TRIPLEX-K-2 also has an emergency seal. This is integrated within the rear flap. This is an additional safety feature and is actuated manually. The emergency seal can be easily actuated without a great deal of force and is safely in position when a loud click is heard. Note that when the emergency seal is lokked in position, it also prevents wastewater generated in the building from flowing into the sewer! It is therefore very important that this emergency seal is reopened again immediately after returning to the building, e.g. after a holiday. 10 Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Height adjustable top section for perfect adaptation to floor level Optional step-wise height adjustable sealing flange for flexible adaptation to the sealing level Easily convertible to an automatic backflow stop for wastewater containing faeces Installation example ACO TRIPLEX-K-2 double backflow stop, DN 100 Type 2 pursuant to EN for installation within floor plates. Figure shows TRIPLEX-K-2 with optional sealing flange to protect the device against pressurised water.

11 Article description ACO TRIPLEX-K-2 double backflow stop, DIN. Type 2 pursuant to EN for installation in floor plates. With telescopic, adjustable top section and cover plate K3. Retrofittable with adjustable flange to seal against pressurised water. For wastewater free of faeces (grey water), for installation in pipe systems, gradient 12 mm, with two automatically closing backflow flaps, with integrated emergency seal. Safe manual locking with audible click signal when locked, with cleaning and maintenance opening and inspection pipe. Convertible to automatic Type 3F backflow stop for use with wastewater containing faeces pursuant to DIN EN Weight 6.5kg Article No. DN Ø (mm) L (mm) H (mm) H1 (mm) For optional components and accessories see page 18/19. Ø x DN H H1 L

12 New! ACO TRIPLEX-K-2 double backflow stop The ACO TRIPLEX-K-2 double backflow stop corresponds to Type 2 EN This product is specially designed for installation in an unenclosed wastewater pipe. This backflow stop is naturally also suitable for subsequent installation in existing shafts thanks to its compact dimensions. This backflow stop is specified for use with wastewater free of faeces. It must only be connected to drainage installations generating wastewater free of faeces, e.g. floor drains, showers or washing machines located below the backflow level. During normal operating conditions, the flaps hang loose. The force of flowing wastewater pushes open the flap in the flow direction to drain the wastewater in the direction of the sewer. If there is backflow, the wastewater backing up from the sewer flows against the normal flow direction and comes into contact with the outer backflow flap. This prevents wastewater from the sewers from flowing back into the building. The second flap is an extra safety feature to ensure that the backflow stop functions even when the first flap fails to close properly because of the presence of dirt, etc. The ACO TRIPLEX-K-2 also has an emergency seal. This is integrated within the rear flap. This is an additional safety feature and is actuated manually. The emergency seal can be easily actuated without a great deal of force and is safely in position when a loud click is heard. Note that when the emergency seal is lokked in position, it also prevents wastewater generated in the building from flowing into the sewer! It is therefore very important that this emergency seal is reopened again immediately after returning to the building, e.g. after a holiday. Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Easily convertible to an automatic backflow stop for wastewater containing faeces 12 Installation example ACO TRIPLEX-K-2 double backflow stop, DN 100 Type 2 pursuant to EN for installation in unenclosed pipes.

13 Article description ACO TRIPLEX-K-2 double backflow stop, DN. Type 2 pursuant to EN for installation in unenclosed drainpipes. For wastewater free of faeces (grey water), for installation in pipe systems, gradient 12 mm, with two automatically closing backflow flaps, with integrated emergency seal. Safe manual locking with audible click signal when locked, with cleaning and maintenance opening and inspection pipe. Convertible to automatic Type 3F backflow stop for use with wastewater containing faeces pursuant to EN Weight 3.5kg Article No. DN Ø (mm) L (mm) H (mm) For optional components and accessories see page 18/ x 250 H DN L

14 New! ACO QUATRIX-K black water automatic backflow stop with shaft system 14 The ACO QUATRIX-K black water automatic backflow stop corresponds to Type 3F pursuant to EN This product is specially designed for installation in floor plates. The backflow stop can be retrofitted with a sealing flange to protect the device from pressurised water. The ACO black water automatic backflow stop is designed for use with wastewater containing faeces. Type 3F backflow stops must be used whenever toilets are installed below the backflow level. Two flaps are open during normal operations. When water from the sewers backflows into the pipes, the operating stop is automatically closed by a pneumatic/electric control device. As soon as the wastewater rises up above the permissible height in the pipe, an under pressure sensor sends a signal back to the control unit. The control unit automatically operates the electric motor to close the operating stop. When water no longer backflows into the system, a sensor informs the control unit and the flap is automatically reopened. The drainage installations connected to the backflow stop must not be used during a backflow situation! The presence of backflow is signalled by an optical and acoustic alarm. An integrated battery maintains continuous operations for up to 24 hours during a power cut. The ACO QUATRIX-K also contains a manually operated emergency seal. The seal can be used manually. The flap can be turned into two positions. Picture 1: Operating seal and emergency seal are open. Wastewater can be drained. Picture 2: Operating seal closes automatically during backflow. An optical and visual alarm is signaled. Picture 3: If needed, the emergency seal can be closed manually. Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Height adjustable top section for perfect adaptation to floor level Optional step-wise height adjustable sealing flange for flexible adaptation to the sealing level Pneumatic sensor for problem-free operation Installation example ACO QUATRIX-K black water automatic backflow stop, DN 100 Type 3F pursuant to EN for installation in floor plates. Figure shows the ACO black water automatic backflow stop with the optional sealing flange to protect against pressurised water.

15 Article description ACO QUATRIX-K black water automatic backflow stop, DN... Type 3F pursuant to EN for installation in floor plates. With telescopic, height adjustable top section and cover plate K3. Retrofittable with adjustable flange to seal against pressurised water. For water containing faeces (black water) and wastewater without faeces (grey water), flood safety classification IP 68. For installation in pipes, gradient 12 mm, with double backflow safety valve, with automatic operating seal, with manually actuated emergency seal, with cleaning and maintenance opening, with inspection pipe. Electric control box IP 56, with optical and acoustic backflow warning, emergency power supply with safety battery including all connection cables. Weight 10.0 kg Article No. DN Ø (mm) L (mm) H (mm) H1 (mm) Optional components and accessories see page 18/19. Ø x DN H H1 L

16 New! ACO QUATRIX-K black water automatic backflow stop The ACO QUATRIX-K black water automatic backflow stop corresponds to Type 3F pursuant to EN This product is designed for use with wastewater containing faeces. Type 3F backflow stops must be used whenever toilets are installed below the backflow level. Two flaps are open during normal operations. When water from the sewers backflows into the pipes, the operating stop is automatically closed by a pneumatic/electric control device. As soon as the wastewater rises up above the permissible height in the pipe, an under pressure sensor sends a signal back to the control unit. The control unit automatically operates the electric motor to close the operating stop. When water no longer backflows into the system, a sensor informs the control unit and the flap is automatically reopened. The drainage installations connected to the backflow stop must not be used during a backflow situation! The presence of backflow is signalled by an optical and acoustic alarm. An integrated battery maintains continuous operations for up to 24 hours during a power cut. The ACO QUATRIX-K also contains a manually operated emergency seal. The seal can be used manually. The flap can be turned into two positions. Position 1: Emergency seal closed no wastewater can be drained Position 2: Emergency seal opened wastewater can be drained. Operating seal closes automatically during backflow. 16 Product benefits Minimal intrinsic gradient 12 mm, and so optimal for refurbishment Height adjustable top section for perfect adaptation to floor level Optional step-wise height adjustable sealing flange for flexible adaptation to the sealing level Pneumatic sensor for problem-free operation Installation example ACO QUATRIX-K black water automatic backflow stop, DN 100 Type 3F pursuant to EN for installation in unenclosed drainpipes.

17 Article description ACO QUATRIX-K black water automatic backflow stop, DN... Type 3F pursuant to EN for installation in unenclosed drainpipes. For water containing faeces (black water) and wastewater without faeces (grey water), flood safety classification IP 68. For installation in pipes, gradient 12 mm, with double backflow safety valve, with automatic operating seal, with manually actuated emergency seal, with cleaning and maintenance opening, with inspection pipe. Electric control box IP 56, with optical and acoustic backflow warning, emergency power supply with safety battery including all connection cables. Weight 10.0 kg Article No. DN Ø (mm) L (mm) H (mm) Optional components and accessories see page 18/ x DN H L

18 Product DN order no. ACO single backflow stop TRIPLEX-K-0, DN Type 0 pursuant to DIN EN for installation in an unenclosed rainwater pipe. Installation in pipes, with an automatically closing backflow flap, cleaning and maintenance opening. Weight 3.5kg ACO single backflow stop TRIPLEX-K-0, DN Type 0, pursuant to DIN EN for installation in floor plates, for rainwater. With telescopically adjustable top section, and cover plate K3. Retrofittable with adjustable flange to seal against pressurised water. For installation in pipes, with automatically closing backflow flap, cleaning and maintenance opening. Weight 6.5kg ACO single backflow stop TRIPLEX-K-1, DN..., Type 1, pursuant to DIN EN 13564, for installation in unenclosed pipes for rainwater. For installation in pipes, with an automatically closing backflow flap, with integrated emergency seal, secure manual closing with audible locking signal, cleaning and maintenance opening. Weight 3.5kg 18 ACO single backflow stop TRIPLEX-K-1, DN Type 1, pursuant to DIN EN for installation in floor plates for rainwater. With telescopically adjustable top section, and cover plate K3. Retrofittable with adjustable flange for sealing against pressurised water. For installation in pipes, with automatically closing backflow flap, with integrated emergency seal, safe manual locking thanks to audible locking signal, with cleaning and maintenance opening. Weight 6.5kg ACO cleaning pipe TRIPLEX-K, DN for installation in unenclosed pipes Retrofittable with backflow stop Type 0, 1, 2 or 3F. Weight 6,5 kg ACO cleaning pipe TRIPLEX-K, DN for installation in floor plates Retrofittable with backflow stop Type 0, 1, 2 or 3F. Weight 6,5 kg

19 Optional components and accessories Product order no. Product order no. Conversion kit for QUATRIX-K black water automatic backflow stop Type 3F. For converting cleaning pipes or backflow stops for wastewater free of faeces. DN 100/DN 150 ACO locking cover l including rubber seal for ACO TRIPLEX-K-0 single backflow stop Type 0 ACO TRIPLEX-K cleaning pipe DN 100/DN 150 ACO conversion kit for TRIPLEX-Kdouble backflow stop Type 2. For conversion of cleaning pipes and backflow stops Types 0 or 1. DN 100/DN 150 ACO extension with lip seal for ACO backflow stops and ACO cleaning pipes for installation in floor pipes DN 100/DN 150 Installation height 100 mm ACO operating sealing flap with push-in component for ACO QUATRIX-K black water automatic backflow safety valve Type 3F. DN 100/DN 150 ACO sealing flange for ACO backflow stops and ACO cleaning pipes for installation in floor plates DN 100/DN 150 ACO emergency sealing flap with push-in component for ACO QUATRIX-K black water automatic backflow stop Type 3F. DN 100/DN 150 ACO top section For ACO backflow stops and ACO cleaning pipes for installation in floor plates. DN 100/DN 150 ACO control box Protection Type IP56 for ACO QUATRIX-K black-water automatic backflow stop Type 3F. DN 100/DN 150 ACO reversing cover, surface-water tight, For ACO backflow stops and ACO cleaning pipes for installation in floor plates. DN 100/DN ACO drive with 5 metres of cable for ACO QUATRIX-K black water automatic backflow safety valve Type 3F. DN 100/DN 150 ACO test pipe for ACO TRIPLEX-K-2 and ACO QUATRIX-K ACO backflow sealing flap with push-in component for ACO TRIPLEX-K-2 double backflow stop Type 2, ACO TRIPLEX-K-1 single backflow stop Type 1, ACO TRIPLEX-K-0 single backflow stop Type 0. DN 100/DN 150 ACO locking cover including rubber seal for ACO TRIPLEX-K-2 double backflow stop Type 2, ACO TRIPLEX-K-1 single backflow stop Type 1. DN 100/DN 150

20 New! ACO SINKAMAT-K mini lifting plant, underground The ACO SINKAMAT-K underground mini lifting plant is an innovative solution for draining parts of buildings located beneath the backflow level. It is suitable for installation in floor plates. The lifting plant can also be installed in water-impermeable concrete by using the optional ACO sealing flange. This product is used for draining wastewater free of faeces. Drainage installations lying below the public sewers can only be drained into the public sewers by using an automatic wastewater lifting plant. The ACO SINKAMAT-K underground mini lifting plant also provides optimal protection against backflow because the pressure pipe has to be led above the backflow level. The mini lifting plant consists of a collecting tank with three DN 100 inlet sockets, a height adjustable top section, and a pump with a float switch and integrated backflow flap. The collecting tank is made of high quality polyethylene with high chemical resistance, and high impact and collision resistance. A range of top sections are available. The wastewater from showers, washing machines etc. being drained from cellars flows into the inlet of the collecting tank. The float switch switches the pump on and off as required. The powerful pump has a quick connection for easy installation and dismantling without the use of tools. It has a capacity of up to 8 m 3 per hour and can suck out water to a depth of 10 mm. Maximum pump height 6.5m. Installation example 20 ACO SINKAMAT-K underground mini lifting plant for wastewater free of faeces, for installation in floor plates.

21 Article description ACO SINKAMAT-K mini lifting plant for rooms lying below the backflow level, for wastewater free of faeces. High quality polyethylene tank for buried installation with DN 100 inlet sockets. With height adjustable top section, external dimensions 198 x 198 mm, height adjustable mm. Grey water submersible pump, with 220 volt AC motor, 50 HZ, 0.37 kw, 2850 rpm. 5m connection cable, winding protection and float switch for low switch-on height, with integrated backflow flap and pressure pipe connection AG R 1 1/2". The pump has a quick connection for installation and dismantling without tools. Suitable for grain sizes up to 10 mm, maximum operating temperature 40 C. Hmax: 6.5m Qmax: 8 m 3 /h Article No ø 430 ø 110 ø 110 ø ø 520

22 New! ACO SINKAMAT-K above-floor mini lifting plant The ACO SINKAMAT-K above-floor mini lifting plant is an innovative solution for draining rooms lying below the backflow level. It is particularly suitable for drainage installations in cellars such as showers, washing machines or sinks for which no fitted drainage was originally planned. This product is used for draining wastewater free of faeces. Drainage installations lying below the public sewers can only be drained into the public sewers by using an automatic wastewater lifting plant. The ACO SINKAMAT-K above-floor mini lifting plant also provides optimal protection against backflow because the pressure pipe has to be led above the backflow level. The mini lifting plant consists of a collecting tank onto which several inlets can be connected in situ, and a pump with a float switch and integrated backflow flap. The collecting tank is made of high quality polyethylene with high chemical resistance, and high impact and collision resistance. Thanks to its new modern shape, with the compact dimensions (l x w x h) 416 mm x 329 mm x 330 mm, the abovefloor lifting unit can be easily installed beneath the usual sinks. The repositioned inspection opening enables the cover of the lifting plant to be easily removed forwards. This means that it is no longer necessary to dismantle the odour trap beneath the sink. The wastewater from showers, washing machines etc. being drained from cellars flows into the inlet of the collecting tank. The float switch switches the pump on and off as required. The powerful pump has a quick connection for easy installation and dismantling without the use of tools. It has a capacity of up to 8 m 3 per hour and can suck out water to a depth of 10 mm. Maximum pump height 6.5m. Installation example 22 ACO SINKAMAT-K above-floor mini lifting plant for wastewater free of faeces for free standing installation in frost-free rooms.

23 Article description ACO SINKAMAT-K mini lifting plant For draining rooms below the backflow level, for wastewater free of faeces. High quality polyethylene tank for above-floor installation, modern shape with compact dimensions. Rearranged front-facing inspection opening, with tank venting and active charcoal filter. Several inlets of various sizes up to DN 50 can be connected to the tank in situ. Grey water submersible pump, with 220 volt AC motor, 50 HZ, 0.37 kw, 2850 rpm. 5m connection cable, winding protection and float switch for low switch-on height, with integrated backflow flap and pressure pipe connection AG R 1 1/2". The pump has a quick connection for installation and dismantling without tools. Suitable for grain sizes up to 10 mm, maximum operating temperature 40 C. Hmax: 6.5 m Qmax: 8 m 3 /h Article No

24 ACO MULI-STAR mono lifting plant The ACO MULI-STAR lifting plant is a black water lifting unit. It is used to drain wastewater from deep lying drainage installations such as toilets, visitor WCs, showers or complete bathrooms. The lifting plant consists of a collecting tank with several factory fitted DN 100 inflows at various heights and positions. The unit also has an assembled pump controlled by a control box and a pneumatic control cable. The compact dimensions of the ACO MULI-STAR are suitable for free standing installation or installation in situ in a shaft. The free flow impeller in the pump guarantees blockage-free operation of the lifting plant. Almost maintenance-free pneumatic water level control for safe switching on and off. The control box has a display showing the current status of the appliance. The lifting plant can also be equipped with an optional manual membrane pump. This means that wastewater can be safely pumped over the backflow level into the sewers even during maintenance work or power cuts. Installation example 24 ACO MULI-STAR lifting plant for black water is shown here as a free standing installation in a frost free room.

25 Article description Wastewater and black water lifting plant consisting of: Polyethylene collecting tank, with drain plug and connection for manual membrane pump R1 1/2 ", fastening kit for bolting down to prevent floating. Total tank volume: 55 litres, working volume of tank variable depending on inlet height, for 180 mm inlet height: 21 litres, for 250 mm inlet height: 28 litres, for 400 mm inlet height: 43 litres. With three horizontal DN 100 inlet sockets and a DN 100 venting socket for connection to plastic pipes. Special DN 80 backflow valve with drainage tap R 1/2", with integrated DN 100 special fastening for elastic connection to pressure pipe, for connection to pipes with external pipe diameters from 108 to mm, with connecting flange for DN 80 stop valve, PN 10. Pump unit 400 V, 50 Hz, protection Type IP 68, with shaft seal and circular rotating mechanical seal, including unblockable free-flow impeller. Pneumatic water level switch with pilot tube and 4 metres of pneumatic control pipe. Control box and alarm unit IP 54 with 1.5m cable and CEE plug, with potential-free group alarm. Weight approx. 65kg Article No Ø 108 bis 114,3 Special fastening DN 100 Free-flow centrifugal pump Special backflow valve DN 80 ca Ø Pilot tube Inlet sockets nominal width DN Polyethylene wastewater collecting tank Ø Drain plug Elevation X back of collecting tank Hose socket Ø 48 for connection to manual membrane pump R 1 1/2" 55

26 ACO MULI-STAR duo twin lifting plant The ACO MULI-STAR duo lifting plant is a black water lifting unit. The lifting plant is designed for draining toilet facilities, washrooms and shower rooms, as well as bathrooms in multifamily houses, office buildings or commercial applications (e.g. downstream of grease separators). The lifting plant consists of a collecting tank with several factory fitted DN 100 and DN 150 inflows at various heights and positions. The unit also has two assembled pumps alternately controlled by a control box with a pneumatic control cable. The compact dimensions of the ACO MULI-STAR are suitable for free standing installation or installation in situ in a shaft. The free flow impellers in the pumps guarantee blockage-free operation of the lifting plant. Almost maintenance-free pneumatic water level control for safe switching on and off. The control box has a display showing the current status of the appliance. The lifting plant can also be equipped with an optional manual membrane pump. This means that wastewater can be safely pumped over the backflow level into the sewers even during maintenance work or power cuts. Installation example 26 ACO MULI-STAR twin lifting plant for black water is shown here as a free standing installation in a frost free room.

27 Article description Wastewater and black water lifting plant consisting of: Polyethylene collecting tank, with drain plug and connection for manual membrane pump R1 1/2 ", fastening kit for bolting down to prevent floating. Total tank volume: 77 litres, working volume of tank variable depending on inlet height, for 180 mm inlet height: 38 litres, for 250 mm inlet height: 46 litres, for 400 mm inlet height: 61 litres. With two horizontal DN 100 inlet sockets, a stepped DN 100/150 inlet socket, and a DN 100 venting socket for connection to plastic pipes. Two special DN 80 backflow valves with drainage taps R 1/2", with Y-branch pipe, with integrated DN 100 special fastening for elastic connection to pressure pipe, for connection to pipes with external pipe diameters from 108 to mm, with connecting flange for DN 80 stop valve, PN 10. Two pump units 400 V, 50 Hz, protection Type IP 68, with shaft seal and circular rotating mechanical seal, including unblockable free-flow impeller. Pneumatic water level switch with pilot tube and 4 metres of pneumatic control pipe. Control box and alarm unit IP 54 for alternate pump operations, with 1.5m cable and CEE plug, with potential-free group alarm. Weight approx. 150kg Article No Ø 108 bis 112 Special fastening DN 100 Free-flow centrifugal 27 Y-branch pipe DN 100/100/100 Special backflow valve DN 70 Ø 110 Pilot tube ca Polyethylene wastewater collecting tank passavant Ø Drain plug Inlet socket variable nominal width DN 100/150 Inlet sockets nominal width DN 100 Elevation X back of collecting tank Hose socket Ø 48 for connection to manual membrane pump R 1 1/2"

28 New! ACO MULI-MAX-F mono pump shaft The ACO MULI-MAX-F pump shaft made of PE-HD has particularly compact dimensions. The telescopic height-adjustable top section enables installation to a total depth of 3 metres. The pump shaft is structurally designed to be fitted with a class B 125 manhole cover without any in situ concrete work, e.g. without having to reinforce the area around the cover. Thanks to its innovative design, the new ACO pump shaft cannot be pushed upwards by groundwater even if the water table rises to the top of the manhole cover. The collection tank is shaped to prevent the collection of sediment. The inside is designed to accommodate a whole range of different pump types depending on the specifications and applications. The pressure pipe and the tension chain are made of high quality stainless steel. The pneumatic water level switch guarantees high levels of operational safety. Two types of control box are available (with and without display), which guarantee optimal function and monitoring. The ACO MULI-MAX-F multipurpose pump shaft is suitable for single and multifamily homes, for commercial properties, in industry, and for syphonic drainage. Installation example 28 ACO MULI-MAX-F pump shaft is made of polyethylene with a pre-assembled black water submersible pump

29 Article description ACO MULI-MAX-F mono pump shaft made of PE-HD with class A 15 or B 125 manhole cover, total installed depth up to 3m with telescopic height-adjustable top section. Cannot be pushed upwards by groundwater even if the water table rises to the top of the manhole cover, no additional in situ concrete measures required, structural certification up to 3m total installation depth. General Building Supervisory Authority Authorisation: applied for Consisting of: Shaft section made of polyethylene, with sediment-free shaft floor, Nominal diameter 1043 mm, With automatic above-water coupling, grey cast iron powder-coated cross beam holding an ACO submersible motor pump, with pressure pipe connection DN 50 or R 2" made of stainless steel, and one ball valve G 2" with spindle extension, vertically sealing ball backflow valve G 2", pressure pipe outlet PE with DA 63 mm (bolt clamps supplied), length from top shaft to centre pressure pipe 1050 mm, layout nine o clock. 1 x DN 150 inlet, length from top shaft to centre inlet 775 mm, layout three o clock (supplied with seals), 2 x DN 100 connection sockets for blank cable duct (venting) layout six o clock and twelve o clock, length base shaft to centre connection socket 1439 mm, with coupling sokket R 1/2 " for rinsing connection (optional accessory) with open impoundment bell and control for ON-OFF alarm function and 10 m pneumatic control cable with ACO black water submersible motor pump: Type: SITA 260 N-ex, protection type IP 68, 400 V, 50 Hz, with stainless steel pipe and guide element for above-water coupling with stainless steel chain and 10 m cable, Note: different pump types for a whole range of applications available upon request Article Article No. Shaft Class A (total installation depth 1900 mm) Shaft Class B (total installation depth 1950 mm) Top section: short (total installation depth to 2350 mm) Top section: long (total installation depth to 3000 mm) Pump SITA 260 N-ex Control box without display Section A-A DN 100 connection for blank cable duct or vent pipe Operating key with chain Option: rinsing connection R 1 1/2" (C coupling) Infinitely height adjustable top section Manhole cover class A DIN EN 124 DN 100 connection for blank cable duct or vent pipe Pressure sensor Pressure pipe: Bolted clamp connection for external pipe Ø 63 DN 100 connection for blank cable duct or vent pipe Base pressure sensor Inlet

30 New! ACO MULI-MAX-F duo pump shaft The ACO MULI-MAX-F pump shaft made of PE-HD has particularly compact dimensions. The telescopic height-adjustable top section enables installation to a total depth of 3 metres. The pump shaft is structurally designed to be fitted with a class B 125 manhole cover without any in situ concrete work, e.g. without having to reinforce the area around the cover. Thanks to its innovative design, the new ACO pump shaft cannot be pushed upwards by groundwater even if the water table rises to the top of the manhole cover. The collection tank is shaped to prevent the collection of sediment. The inside is designed to accommodate a whole range of different pump types depending on the specifications and applications. The pressure pipe and the tension chain are made of high quality stainless steel. The pneumatic water level switch guarantees high levels of operational safety. Two types of control box are available (with and without display), which guarantee optimal function and monitoring. The ACO MULI-MAX-F multipurpose pump shaft is suitable for single and multifamily homes, for commercial properties, in industry, and for syphonic drainage. Installation example 30 ACO MULI-MAX-F pump shaft is made of polyethylene with two pre-assembled black water submersible pumps

31 Article description ACO MULI-MAX-F duo pump shaft made of PE-HD with class A 15 or B 125 manhole cover, total installed depth up to 3m with telescopic height-adjustable top section. Cannot be pushed upwards by groundwater even if the water table rises to the top of the manhole cover, no additional in situ concrete measures required, structural certification up to 3m total installation depth. General Building Supervisory Authority Authorisation: applied for Consisting of: Shaft section made of polyethylene, with sediment-free shaft floor, Nominal diameter 1043 mm, With automatic above-water coupling, grey cast iron powder-coated cross beam holding two ACO submersible motor pumps, with pressure pipe connection DN 50 or R 2" made of stainless steel, and one ball valve G 2" with spindle extension, vertically sealing ball backflow valve G 2", pressure pipe outlet PE with DA 63 mm (bolt clamps supplied), length from top shaft to centre pressure pipe 1050 mm, layout nine o clock. 1 x DN 150 inlet, length from top shaft to centre inlet 775 mm, layout three o clock (supplied with seals), 2 x DN 100 connection sockets for blank cable duct (venting) layout six o clock and twelve o clock, length base shaft to centre connection socket 1439 mm, with coupling sokket R1/2" for rinsing connection (optional accessory) with open impoundment bell and control for ON-OFF alarm function and 10 m pneumatic control cable with two ACO black water submersible motor pumps: Type: SITA 260 N-ex, protection type IP 68, 400 V, 50 Hz, with stainless steel pipe and guide element for above-water coupling with stainless steel chain and 10 m cable. Note: different pump types for a whole range of applications available upon request Article Article No. Shaft Class A Shaft Class B Top section: short (total installation depth 1905 to 2350 mm) Top section: long (total installation depth 1905 to 3000 mm) Pump SITA 260 N-ex x 2 Control box without display Section A-A DN 100 connection for blank cable duct or vent pipe Operating key with chain Option: rinsing connection R 1 1/2" (C coupling) Infinitely height adjustable top section Manhole cover class A DIN EN 124 DN 100 connection for blank cable duct or vent pipe Pressure sensor Pressure pipe: Bolted clamp connection for external pipe Ø 63 DN 100 connection for blank cable duct or vent pipe Base pressure sensor Inlet

32 ACO Building Drainage product range Drainage Flat roof, balcony and terrace drains Floor drains and channels Bathroom systems Pipe systems Backflow stops Manhole covers Separating Grease separators Starch separators Process engineering Pumps Wastewater lifting plant Submersible pumps Prefabricated pumping stations ACO Passavant GmbH Drainage stainless steel / plastic Pipe systems Separating technology Pumps / Lifting plant Im Gewerbepark 11c Stadtlengsfeld Tel Fax Drainage cast iron Postfach Aarbergen Tel Fax The ACO Group. A strong family you can build on.