1 Air Solutions International P/L Solutions to Indoor Air Problems Vapor Absorption Chillers 1

2 Hot Water Driven Chillers Single Effect Water temp ºC COP kW 2

3 Hot Water Fired Single Effect Water ºC COP kw Hot Water Fired Double Effect Water Temp ºC COP kW 3

4 Steam Fired Single Effect Steam Pressure kpa COP ,000 kw 26 Models Steam Fired Double Effect Steam Pressures kPa980kPa ,000 kw Chilled water to 3.5ºC Cooling water to 10ºC 4

5 Multi Fuel Double Effect Light Oil, Natural gas, Diesel Oil Kerosene Oil (SKO) LPG, Bio Gas kw COP % 100% Step Control Tri-Generation Direct Exhaust Exhaust & Jacket Water Auxiliary Firing ,000 10,000 kw % 100% Modulating Designed to Suit Generator 5

6 Tri-Generation STACK EXHAUST DAMPER JACKET WATER COOLING HEATING POWER Tri-Generation 6

7 Tri-Generation Three Way Exhaust Damper 7

8 Compactness at the cost of Reliability Low LiBr temp. Higher Absorbity More capacity from M/C DISTANCE ONLY 5º FROM CRYSTALLISATION LINE (OTHERS) CRYSTALLISATION POINT 36ºc 41ºc 50ºc CRYSTALLISATION LINE CONCENTRATION LINES OTHER S RATED ABSORBER INLET CONDITION (From operation manual) THERMAX RATED ABSORBER INLET CONDITION 64% CONCENTRATION LINE DISTANCE MORE THAN 10º FROM CRYSTALLISATION LINE (THERMAX) Tube Crystallisation JACKET TUBE FOR TUBE CRYSTALLISATION Thermax has designed unique crystallisation prevention logic which is as explained below - LiBr solution crystallises at a particular temperature and concentration. The variation of concentration of LiBr with respect to temperature of the solution is plotted in the form of a graph. The graph also shows the crystallisation line of LiBr at various temperatures and concentrations. Crystallisation of LiBr solution in vapour absorption machines can be prevented by preventing the LiBr from operating at any point close to the crystallisation line. Thus, in Thermax s crystallisation free machines, it is ensured that LiBr operates always at a safe distance from the crystallisation line. The concentration of the strong solution of LiBr is measured continuously and accurately. Incorporating the most advanced & unique logic the concentration is always kept at a safe distance above the crystallisation point. 8

9 Inherent Features SERIES FLOW DESIGN Thermax uses more reliable advanced series flow design for heat exchangers. Thermax has designed the High Temperature Generator very efficiently to lower the LiBr volume. This ensures lower energy consumption at start up. LiBr temperature is around 155 C and LiBr concentration is only 61%. This reduces the corrosion effect of LiBr & enhances life of the chiller. PART LOAD PERFORMANCE Thermax chillers are designed at ARI 560 / JIS standards as applicable & run satisfactorily at even 10% load. ABSORBENT & REFRIGERANT PUMPS Normally the pump manufacturers recommend NPSH for pumps as 0.5 m. They have Isolation valves helps to carry out maintenance without disturbing vacuum inside the chiller. REMOTE MONITORING Thermax chillers are compatible with MODBUS protocol to transfer all the data available on the control panel display. The system can be made compatible with LONWORKS, PROFIBUS, SCADA or local BMS networks. Inherent Features ELIMINATORS IN EVAPORATOR - Thermax uses unique design of eliminators / baffles which has low pressure drop on account of better spacing between tube bank & eliminator. This ensures a smooth path for the vapour (without any water Carry over) from evaporator to absorber. AUTO-PURGE SYSTEM Thermax chillers are designed with robust system to collect all the non-condensable gases generated in the process. Offer OPTIONAL Automatic Purge to Drain System. CONDENSER WATER INLET TEMPERATURE Thermax chillers can run at much lower condensing water inlet temperatures (as low as 15 C). This is possible on account of its innovative crystallization control logic. NOZZLE SPRAYING IN ABSORBER Thermax chillers have gravity feed design spray where the PLC logic completely controls crystallization to ensure proper penetration at all times. 9

10 Thermax in Australia Monash University [8 units] Gas & High Temp Hot Water. South Australia [3 units] Transport SA: Hot water. Regency TAFE: Hot Water Tri-generation Underdale High school: Gas Fired Hawksberry City Council: Gas fired CSIRO: Hot Water Fired CH2 Building Melbourne: Hot Water Fired Essendon Hospital: Steam Fired Queen Victoria Building: Gas fired [4 units] Blackmores: Tri-generation Exhaust & Jacket Water.[2 Units] Miller Street Nth Sydney: Tri-generation Exhaust & Jacket Water. [2] 100 Market St Sydney: Tri-generation Exhaust & Jacket Water. [3] Darling Island: Gas Fired 111 Eagle Street Brisbane: Tri-generation Queensland University of Technology: Tri-generation University of NSW: Hot water fired Ferrero Chocolates: Hot Water Fired 179 Queens Street Melbourne: Hot Water Fired using Micro Turbines CIT Canberra: Hot Water Fired using Micro Turbines King George Building Tri-generation Solar Cooling Thermax Parabolic Dish Collector 10

11 Evacuated Tube Collectors Parabolic Trough Collectors 11

12 Solar Cooling COOLING TOWER ABSORPTION CHILLER CHILLED WATER HOLDING TANK What Type of Machine to Select? Thermax Offers single double effect machines. Depending on hot water temperature machine will work as single or double or single-double effect. Single effect machines give a COP of 0.73 (75C+) Double effect Machines give COP of 1.44 (170C+) Triple effect Machine on trial in Deli using Solar COP (When released on the market in 6-8 months will be the most efficient Vapor Absorption Machine in the world) 12

13 Solar Cooling Project Solar Cooling Project 13

14 Tesco Lotus Bangkok Under Cover Car Park 14

15 Absorption Chiller Cooling Tower & Tank 15