RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE

Size: px
Start display at page:

Download "RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE"

Transcription

1 RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE Digital Technology for optimized measures Combination ph/redox/temp sensor Digital Sensor : Modbus RS 485 / SDI-12 Calibration data inside ph/orp Cartridge Range ph : 0 to 14 units Redox : to mv ; T C : -10 C to +50 C Introduction The PHEH sensor has been designed to perform under hard conditions from pure mountains water withconductivity as low as 20 μs/cm, lakes and rivers ( μs/cm), seawater with conductivities of 50 ms/cm and to wastewater with conductivity higher than 200 ms/cm. This sensor features a long life reference. The Plastogel PONSEL technology increase the lifetime of the probe the need to refill. This sensor has been designed also for handheld and in situ applications which have been the most difficult situations for a ph/orp sensor in term of sensor resistance, quick time response, minimal flow dependence and low power consumption. Digital Technology : The smart ph/redox/temp sensor stores calibration and history data within the sensor. This allows you a plug and play system without re-calibration. Thanks to the Universal Modbus RS485 protocol, the PONSEL ph/redox/t sensor can be connected to all devices commonly used (Datalogger, Controller, Automat, Remote System.) West Yorkshire HX4 8LR

2 RANGE DIGISENS PHEHT : PH, REDOX & TEMPERATURE ph Measure principle Range Resolution Accuracy Redox Measure principle Range Resolution Accuracy Temperature Technology Range Combined electrode (ph/ref) : special glass, Ag/AgCI ref. Gelled electrolyte (KCI) 0-14 ph 0,01 ph +/- 0,1 ph Combined electrode (Redox/reference) : Platinum tip, Ag/AgCI AgAgCl. Gelled reference (KCI) to mv 0,1 mv ± 2 mv CTN 0,00 C à + 50,00 C Resolution 0,01 C Accuracy ± 0,5 C Response time < 5 s Storage temperature 0 C to + 60 C Protection IP 68 Interface Power supply Power consumption Sensor Dimensions Weight Material Pressure Cable Protection Modbus RS-485 / SDI-12 (option) 5 to 12 volts Standby : 25μA, Average RS485 (1 measure/seconde) : 3,9 ma, Average SDI12 (1 measure/seconde) : 6,8 ma, Current pulse : 500 ma Diameter : 27 / 21 mm ; Lenght : 207 mm 350 g (sensor + 3 m cable) PVC, special ph glass, platinum 5 bars Coaxial armoured, Polyurethane, bare wire or Fisher connector IP68 West Yorkshire HX4 8LR

3 DIGITAL SENSOR C4E : CONDUCTIVITY/SALINITY Digital Technology for optimized measures 4 electrodes (2 graphic, 2 platinum) Range 0 to 200 ms/cm Digital sensor / Modbus RS-485 Robust and Watertight Applications Urban wastewater treatment Industrial effluent treatment Surface water monitoring Sea water Drinking water Mounting at 4 electrodes: The electrode works with a technology in 4 electrodes: an alternating current of constant-voltage is established between a primary s pair of electrodes in graphite. The secondary s electrodes in platinum allow of regulate the voltage imposed to primary s electrodes to reflect of the fouling. The voltage measured between the primary s electrodes is in function of the resistance of place and so, of the conductivity. Digital Technology : The smart Digital C4E sensor stores calibration and history data within the sensor. This allows you a plug and play system without re-calibration. Thanks to the Universal Modbus RS485 protocol, the Digital C4E can be connected to all devices commonly used (Datalogger, Controller, Automat, Remote System).

4 DIGITAL SENSOR C4E : CONDUCTIVITY/SALINITY Measures Measure principle Measure ranges conductivity Resolution Accuracy Measure range salinity Measure range TDS -KCl Response time Conductivity sensor with 4 electrodes (2 graphic, 2 platinum) 0-200,0 μs/cm, μs/cm, 0,00 20,00 ms/cm, 0,0 200,0 ms/cm 0,01 to 1 according the range +/- 1 % of the full range 5-60 g/kg ppm < 5 s Working temperature 0 C to 50 C Temperature compensation CTN Stocking temperature - 10 C to + 60 C Signal interface Maximum refreshing time Sensor power-supply Electric consumption Sensor Dimensions Weight Material Maximum pressure Connection Protection Modbus RS-485 ( option SDI-12) Max < 1 s 5 to 12 volts Standby : 25 μa, Average RS485 (1 measure/seconde) : 6,3 ma, Average SDI12 (1 measure/seconde) : 9,2 ma, Current pulse : 500 ma Dimensions Diameter : 27 mm ; Lenght : 177 mm 350g (sensor + 3 m cable) PVC, stainless steel 5 bars 9 armoured connectors, polyurethane jacket, bare-wires or waterproof Fisher connector IP

5 RANGE DIGISENS NEPHELOMETRIC TURBIDITY Optical technology for optimized measures IR optical sensor with optical fibre Range : 0 to 4000 NTU or mg/l Robust and waterproof (IP68) Ultra low-power consumption Digital output Modbus RS-485 Applications ISO 7027 compliance (Nephelometry) Urban wastewater treatment (inlet/ outlet controls) Sanitation network Industrial effluent treatment Surface water monitoring Drinking water Optical technology : The measure principle is based on IR nephelometry / 880 nm (ISO 7027). The sensor can be calibrated with a formazine standard solution. The NTU sensor integrates a low-cost optical technology, with a very few maintenance and no consumables. Digital communication : The PONSEL sensor can be connected to any types of transmitters, display units, controllers or data loggers with Modbus RS-485 or SDI-12 inputs. The optical sensor saves its calibration data for better measures management. Integrated transmitter : All data concerning calibration, history, users and measures are directly treated within the NTU sensor and transmitted via RS-485 or SDI-12. Physical characteristics : Compact, robust and light, the PVC sensor allows a handheld or fixed unit application.

6 RANGE DIGISENS NEPHELOMETRIC TURBIDITY Measures Measure principle Diffusion IR at 90 Measure ranges Resolution Accuracy 0 to 4000 NTU in 5 ranges: 0 50 NTU, NTU, NTU, NTU 0 to 4500 mg/l. Calibration :Range mg/l according to NF EN 872 Range >500 mg/l according to NF T AUTOMATIC 0,01 to 1 NTU - mg/l < 5% of the reading Working temperature 0 C to + 50 C Temperature compensation via CTN Stocking temperature -10 C to + 60 C Signal interface Maximum refreshing time Sensor power-supply Electric consumption Sensor Dimensions Weight Material Maximum pressure Connection Degree of protection Modbus RS-485 (standard) and SDI-12 (option) < 1 second 5 to 12 volts Standby : 40 μa, Average RS485 (1 measure/seconde) : 820 μa, Average SDI12 (1 measure/seconde) : 4,2 ma Diameter : 27 mm; length : 170 mm 300 g (sensor + cable 3 meters) PVC, Quartz, PMMA, Nickel-plated brass 5 bars 9 armoured connectors, polyurethane jacket, bare-wires or waterproof Fisher connector IB68

7 DIGISENS RANGE OPTOD : OPTICAL DISSOLVED OXYGEN Optical technology for optimized measures Optical Technology without calibration Digital Technology (Modbus RS-485) No drift, Reduced maintenance Robust, for field applications Applications Urban wastewater treatment Industrial effluent treatment Surface water monitoring Drinking water Optical technology : The OPTOD (Optical Dissolved Oxygen technology) is based on luminescent optical technology. The OPTOD sensor is approved by the ASTM International Method D Without calibration requirements and thanks to an ultra low power technology, the OPTOD sensor meets the demands of field works and short or long term campaigns. Without oxygen consumption, this technology allows you an accurate measure in all situation and especially in very low oxygen concentrations Digital Technology : The smart OPTOD sensor stores calibration and history data within the sensor. This allows you a plug and play system without re-calibration. Thanks to the Universal Modbus RS485 protocol, the PONSEL OPTOD can be connected to all devices commonly used (Datalogger, Controller, Automat, Remote System).

8 DIGISENS RANGE OPTOD : OPTICAL DISSOLVED OXYGEN Measures Measure principle Optical measure by luminescence Measure ranges 0,00 to 20,00 mg/l, 0,00 to 20,00 ppm, 0-200% Resolution 0,01 Accuracy +/- 0,1mg/L, +/- 0,1 ppm, +/- 1 % Response time Water move Temperature compensation 90% of the value in less than 60 seconds No necessary move Via CTN Stocking temperature - 10 C to + 60 C Signal interface Maximum refreshing time Sensor power-supply Consumption Sensor Dimensions Weight Material Maximum pressure Connection Degree of protection Modbus RS-485 (standard) and SDI-12 (option) < 1 second 5 to 12 volts Standby 25 μa, Average RS485 (1 measure/ seconde) : 4,4 maaverage SDI12 (1 measure/ seconde) : 7,3 ma Current pulse : 100 ma Diameter : 25 mm ; length : 146 mm Weight 450g (sensor + cable 3 meters) Stainless steel 316L 5 bars 9 armoured connectors, polyurethane jacket, barewires or waterproof Fisher connector IB68