1 Sensor Compatibility wasp mote

2 Index Document version: v4.0-02/2013 Libelium Comunicaciones Distribuidas S.L. INDEX 1. Sensor compatibility Gases sensor board Events sensor board Smart Cities sensor board Agriculture sensor board / Agriculture PRO sensor board Smart Metering sensor board / Smart Metering PRO sensor board v4.0

3 1. Sensor compatibility 1. Sensor compatibility This document relates which sensors of the Waspmote platform are connected on each socket of the sensors boards, as long as the special circumstances of each of them. In next sections all the boards are described separately, enumerating the sensors of the board. Example of Sensor Compatibility Scheme: Name / number of the socket Sensors of the board 2A 1. CH 4 2. Air pollutants I 3. Air pollutants II 4. Solvent vapors 5. Liquified petroleum gases Gases sensor board -3- v4.0

4 2. Gases sensor board Humidity 1. Humidity 4 1. CO 2. NH 3 3. CH 4 4. Air contaminants I 5. Air contaminants II 6. Solvent vapors 7. Liquified petroleum gases 3B 1. NO 2 3A Temperature 1. CO 2. NH 3 3. CH 4 4. Air pollutants I 5. Air pollutants II 6. Solvent vapors 7. Liquified petroleum gases Atmospheric presure 1. Atmospheric presure 1B 1. O 2 1A 1. CO 2 2A 2B 1. O 3 2. VOC s sensor 1. CH 4 2. Air pollutants I 3. Air pollutants II 4. Solvent vapors 5. Liquified petroleum gases -4- v4.0

5 3. Events sensor board 8 1. Horizontal liquid level (combustibles) 2. Horizontal liquid level (water) 3. Vertical liquid level (water) 4. Hall efect 5. Water pressence 3 1. Pressure / weight 2. Bend 3. Horizontal liquid level (combustibles) 4. Horizontal liquid level (water) 5. Vertical liquid level (water) 6. Luminosity 7. Hall efect 8. Water pressence 9. Stretch Presence (PIR) 1. Pressure / weight 2. Bend 3. Horizontal liquid level (combustibles) 4. Horizontal liquid level (water) 5. Vertical liquid level (water) 6. Luminosity 7. Hall efect 8. Water pressence 9. Stretch 6 2. Humidity (3,3 V) 5 2. Humidity (3,3 V) 4 1. Vibration (lamina) 2. Vibration (thread) 2 1. Pressure / weight 2. Bend 3. Horizontal liquid level (combustibles) 4. Horizontal liquid level (water) 5. Vertical liquid level (water) 6. Luminosity 7. Hall efect 8. Water pressence 9. Stretch Restrictions and special considerations for this board are described below: Sockets 1, 2 and 3 are very similar and its sensors are almost interchangeable. -5- v4.0

6 4. Smart Cities sensor board LDR sensor 1. Crack detection gauge 2. Crack propagation gauge 3. Luminosity Humidity 1. Humidity Linear displacement 1. Linear displacement Temperature 2. Ultrasound (indoor) 3. Ultrasound (outdoor IP67) Dust sensor 1. Dust - PM-10 Microphone (dbspla) * 1. Microphone (dbspla) *Microphone sensor is calibrated ondemand Restrictions and special considerations for this board are described below: No restrictions. -6- v4.0

7 5. Agriculture sensor board / Agriculture PRO sensor board Humidity Temperature Soil moisture Solar radiation* 1. Humidity 1. Soil moisture 1. Solar radiation 2. Ultraviolet radiation Luminosity 1. Luminosity Atmospheric pressure 1. Atmospheric pressure Soil temperature * 1. Soil temperature Humidity + Temperature 1. Humidity + Temperature Dendrometer * 1. Trunk diameter 2. Stem diameter 3. Fruit diameter Leaf wetness 1. Leaf wetness Weather station 1. Anemometer 2. Wind Vane Pluviometer 1. Pluviometer Restrictions and special considerations for this board are described below: * These sensors are only available on the Agriculture PRO sensor board Each sensor has its own socket. Only one dendrometer at the same time. Wind vane and anemometer go in the same socket -7- v4.0

8 6. Smart Metering sensor board / Smart Metering PRO sensor board Temperature Ultrasonic 3.3V 1. Ultrasound (indoor) 2. Ultrasound (outdoor IP67) Ultrasonic 5V Luminosity 1. Luminosity 1. Ultrasound (indoor) 2. Ultrasound (outdoor IP67) Humidity 1. Humidity Current 1. Current 0-100A Water flow 5V 1. Water flow 0,15-2,5 l/min 2. Water flow 0,5-25 l/min 3. Water flow 1-60 l/min Load cell * 1. Load 0-3Kg 2. Load 0-50Kg 3. Load 0-600Kg Water flow 3.3V 1. Water flow 0,15-2,5 l/min 2. Water flow 0,5-25 l/min 3. Water flow 1-60 l/min * Load cell s electronics are only mounted on demand in the Smart Metering PRO board Restrictions and special considerations for this board are described below: Only one load cell is allowed in each board. -8- v4.0