IWAKI MAGNETIC DRIVE GEAR PUMPS MDG

Size: px
Start display at page:

Download "IWAKI MAGNETIC DRIVE GEAR PUMPS MDG"

Transcription

1 IWAKI MAGNETIC DRIVE GEAR PUMPS

2 Compact gear pumps that completely eliminate Iwaki Series pumps are small seal-less magnetic drive gear pumps engineered to provide the utmost in quiet and leak-free operation. Owing to their remarkable efficiency and compact design, pumps are in wide use in hundreds of varied applications including some of the most sophisticated medical and laboratory equipment. M -MTB Seal-less Construction Ideal for OEM Applications Leak free and seal-less, the Series pumps are ideal for incorporation into equipment. The magnet drive mechanism eliminates the troublesome shaft seal replacement. Outstanding Corrosion Resistance The liquid end parts are manufactured from, PTFE, PPS and PEEK. This combination of materials offers extremely high levels of corrosion resistance thus making the pumps capable of transferring many different aggressive chemical solutions.

3 IWAKI MAGNETIC DRIVE GEAR PUMPS leakage problems R RDCV type M R -RRVB (shown with IEC motor) -RBB -MSB -R High Pressure Gear Rotary System pumps are characterized by high pressure and low flow rate. Despite its small size, it can attain high pressure to. and vacuum of.. Excellent Thermal Resistance Precision machining coupled with Iwaki's innovative technology is used in the gear and body manufacturing process. Because only the most heat-resistant materials are used, pumping problems due to thermal expansion are eliminated. Standard Series pumps are rated for 9 C operation.

4 R RRVB / RBVB Construction and materials No. 9 Name of Part Pump head Gear Shaft Bearing Plate Gear case Gasket seal O ring Magnet capsule Rear casing Retaining spring Adjusting screw Valve Materials GFRPPS PPS (CF+PTFE) PPS, GFRPPS equivalent to (CF+PTFE) PPS 9 Pump identification - R R V B R Temp. range R : - C B : - 9 C Relief valve /NPT with relief valve no symboll : without relief valve : AC - V : ACV Specifications size Standard motors fitted are to IWAKI specifications. All models are also available with IEC frame motors. capacity L/min discharge pressure vacuum (abs.) Pump performance will change depending on kind of liquid. Further information will be provided on request. When handling pure water and solvent, please contact us. When viscosity of handling liquid exceeds limitation of pump, please contact us. For applications requiring higher operating temperatures, please contact us. V motor is also available. Liquid temp. range C Viscosity limit mpa s -RRVB /NPT./... - AC - V, W. -RBVB /NPT./ AC - V, W. /Hz Mass kg Performance curves (Clear water at C) -RRVB -RBVB... Hz Hz. Hz Hz... L/min. L/min....

5 IWAKI MAGNETIC DRIVE GEAR PUMPS R DCV type RBB / RRVAH / RRVBH / RRVCH / RBAH / RBBH / RBCH Construction and materials No. 9 Name of Part Pump head Gear Shaft Bearing Plate Gear case Gasket seal O ring Magnet capsule Rear casing Retaining spring Adjusting screw Valve Materials GFRPPS PPS (CF+PTFE) PPS, GFRPPS equivalent to (CF+PTFE) PPS 9 Pump identification - R R V B H Temp. range R R : - C Relief valve /NPT Note B : - 9 C with relief valve no symboll : without relief valve Note: Other connections (Rc/, G/) are also available on special request but for "-H" models only. Specifications size capacity L/min discharge pressure vacuum (abs.) Liquid temp. range C : DCV, W H : DCV, W Viscosity limit mpa s Mass kg -RBB DCV, W Rc/, -RRV H *.. - /NPT, G/. DCV, W -RB H*. - 9 shows connection size. Please refer above table. Pump performance will change depending on kind of liquid. Further information will be provided on request. When handling pure water and solvent, please contact us. When viscosity of handling liquid exceeds limitation of pump, please contact us. s marked with are manufactured to order only. *. Performance curves (Clear water at C) -RBB -RRV H -RB H L/min.... L/min. L/min.....

6 M M MSB / MTB / MSB / MTBH Construction and materials No. 9 Name of Part Pump body Gear Shaft Plate Gear case Gasket O ring Magnet capsule Rear casing Materials CFRPEEK CFRPEEK/PPS PTFE, PPS Pump identification 9 - M S B M, M Flow rate Pressure S, T M B : /NPT MS B : /NPT : AC - V H : AC - V : ACV Specifications Standard motors fitted are to IWAKI specifications. All models are also available with IEC frame motors. /Hz Liquid Viscosity Mass size capacity discharge pressure vacuum temp. range limit L/min (abs.) C mpa s kg -MSB /NPT./... - AC - V, /W. -MTB /NPT./ AC - V, /W.9 -MSB /NPT./... - AC - V, /W.9 -MTBH /NPT./ AC - V, /W. Pump performance will change depending on kind of liquid. Further information will be provided on request. When handling pure water and solvent, please contact us. When viscosity of handling liquid exceeds limitation of pump, please contact us. V motor is also available. Performance curves (Clear water at C) -MSB -MTB, MTBH.. -MSB.. Hz Hz. Hz Hz. Hz Hz.... L/min. L/min. L/min......

7 IWAKI MAGNETIC DRIVE GEAR PUMPS R RT / RP / RK / RC Construction and materials No. Name of Part Materials Pump body Gear Shaft Bearing Gear case O ring Magnet capsule PTFE/PEEK GFRPTFE, (CF+PTFE) PPS, Rear casing 9 Bearing holder Pump identification 9 - R T R Material of gear /Temp. range T : PTFE gear, GFRPTFE bearing/ - C P : PEEK gear, (CF+PTFE) PPS bearing/ - C K : PTFE gear, GFRPTFE bearing/ -9 C C : PEEK gear, (CF+PTFE) PPS bearing/ -9 C : AC - V : ACV Specifications -RT -RP -RK -RC size Rc/ Rc/ Standard motors fitted are to IWAKI specifications. All models are also available with IEC frame motors. capacity L/min discharge pressure vacuum (abs.) /.. - AC - V,/W../ AC - V,/W. Pump performance will change depending on kind of liquid. Further information will be provided on request. When handling pure water and solvent, please contact us. When viscosity of handling liquid exceeds limitation of pump, please contact us. V motor is also available. Liquid temp. range C Viscosity limit mpa s /Hz Mass kg Performance curves (Clear water at C) -RT -RP.. -RK, RC.. Hz Hz. Hz Hz. Hz Hz..... L/min.. L/min.. L/min

8 IWAKI MAGNETIC DRIVE GEAR PUMPS Dimensions in mm W H L a b c d e f g c L f g b a d W e H -R RBB 9. -R VH * 9. -MSB -M B -M B H ø9 -R 9 Note: s marked with are manufactured to order only. * Dimensions of models fitted with IEC motors differ from above. Applications in Various Fields Dialyser Plasma etching units Freon recovery and regeneration systems Demineralizer Medical appliances Dialyser Laser-applied surgical knife and other laser-applied medical treatment units X-ray film processors Semiconductor or liquid crystal manufacturing equipment Laser-applied machining units Plasma etching units Pure-water or solvent use washing machines Soldering machines IC testing units Printing equipment Blanket auto washers Automatic markers Food processing equipment Noodle producing machines Water coolers Freshness preservation units for food Waste liquid recovery and processing equipment Freon recovery and regeneration systems Photographic chemical waste processing units Organic solvent recovery units Others Pure-water producing machines Oil circulation and filtering units Liquid adding machines for pasturage Hydroponic systems Spraying machines for agricultural chemicals Dye laser units Fuel cells Machines applied in physics and chemistry Laboratories or experimental facilities - Kanda-Sudacho -chome Chiyoda-ku Tokyo - Japan TEL : () 9 FAX : 9 IWAKI has global net work. Please find your distributor location at European office Germany Holland Italy Spain Belgium Denmark Finland France Norway Sweden U.K. : IWAKI Europe GmbH : IWAKI Europe GmbH : IWAKI Europe GmbH (Netherlands Branch) : IWAKI Europe GmbH (Italy Branch) : IWAKI Europe GmbH (Spain Branch) : IWAKI Belgium N.V. : IWAKI Nordic A/S : IWAKI Suomi Oy : IWAKI France S.A. : IWAKI Norge AS : IWAKI Sverige AB : IWAKI Pumps (UK) Ltd. TEL: (9) 9 TEL: (9) 9 TEL: () TEL: (9) TEL: ()9 9 TEL: () TEL: () TEL: ()9 TEL: () 9 TEL: () 9 TEL: () 9 TEL: () FAX: 9 FAX: 9 FAX: (9) 9 FAX: FAX: 9 99 FAX: FAX: FAX: 9 FAX: 9 9 FAX: 9 FAX: 9 FAX: ( )Country codes Caution for safety use: Before use of pump, read instruction manual carefully to use the product correctly. Legal attention related to export. U.S.A. Argentina Singapore Indonesia Malaysia Australia Hong Kong China Korea Taiwan Thailand Vietnam : IWAKI America Inc. : IWAKI America Inc. (Argentina Branch) : IWAKI Singapore Pte Ltd. : IWAKI Singapore (Indonesia Office) : IWAKIm Sdn. Bhd. : IWAKI Pumps Australia Pty Ltd. : IWAKI Pumps Co., Ltd. : GFTZ IWAKI Engineering & Trading Co., Ltd. : IWAKI Pumps (Shanghai) Co., Ltd. : IWAKI Korea Co.,Ltd. : IWAKI Pumps Taiwan Co., Ltd. : IWAKI (Thailand) Co.,Ltd. : IWAKI Pumps Vietnam Co., Ltd. TEL: () 9 TEL: () TEL: () TEL: () 9 TEL: () TEL: () 999 TEL: () TEL: () TEL: () TEL: () TEL: () 9 TEL: () TEL: () 9 Actual pumps may differ from the photos. Specifications and dimensions are subject to change without prior notice. For further details please contact us. Our products and/or parts of products fall in the category of goods contained in control list of international regime for export control. Please be reminded that export license could be required when products are exported due to export control regulations of countries. FAX: 9 FAX: FAX: 9 FAX: FAX: 999 FAX: FAX: 9 FAX: 99 FAX: FAX: FAX: FAX: 999 The posting and copying from this catalogue without permission is not accepted firmly. CAT-E -..IWAKI