ANNEXURE. Annexure 1: Production Details. Annexure 2: Site Location Map. Annexure 3: Site Layout Map & Area breakup for Terminal

Size: px
Start display at page:

Download "ANNEXURE. Annexure 1: Production Details. Annexure 2: Site Location Map. Annexure 3: Site Layout Map & Area breakup for Terminal"

Transcription

1 ANNEXURE Annexure 1: Production Details Annexure 2: Site Location Map Annexure 3: Site Layout Map & Area breakup for Terminal Annexure 4: Operation Philosophy Annexure 5: Copy of Consent to Operate Annexure 6: Storage tank Details Annexure 7: Water consumption & Waste water generation details Annexure 8: Fuel consumption details Annexure 9: Hazardous waste generation details Annexure 10: Stack details Annexure 11: Land Possession documents

2 Annexure 1: Production Details Table 0-1: Details of Existing & Additional Chemicals Storage Material HSD MS SKO Storage Capacity (KL) Existing Additional Total Nos. of Storage Tanks Storage Capacity (KL) Nos. of Storage Tanks Storage Capacity (KL) Nos. of Storage Tanks LDO ATF EMPTY OCTANE ETHANOL Total storage quantity (KL)

3 Annexure 2: Site Location Map

4 Sr. No. Point Latitude Longitude 1 A 28 32'15.97"N 77 3'37.31"E 2 B 28 32'18.01"N 77 3'35.83"E 3 C 28 32'26.19"N 77 3'18.41"E 4 D 28 32'37.89"N 77 3'27.97"E 5 E 28 32'31.67"N 77 3'43.50"E 6 F 28 32'29.18"N 77 3'43.31"E 7 G 28 32'26.39"N 77 3'40.98"E 8 H 28 32'28.37"N 77 3'36.88"E 9 I 28 32'21.18"N 77 3'31.65"E 10 J 28 32'18.92"N 77 3'35.51"E 11 K 28 32'16.96"N 77 3'38.70"E

5 Annexure 3: Site Layout Map

6 The Total site area is 71 Acres. The area details of the existing facility and the additional facilities are given below in the Table. Table 0-2: Area breakup for terminal S. no. Description Area, m 2 (Tentative) % of Total Area 1 Storage tank farm area (existing) Storage tank farm area (additional) Utility area (FE/PH, PH) Administrative Building Building Blocks Parking Roads Green belt area Fire water storage area Loading Unloading area Misc ( TLF, Open space, scrap yard, lube oil, TT Parking, Officers coloney etc ) Total

7 Annexure 4: Operation Philosophy Delhi Terminal, Bijwasan is a Petroleum Product Storage Terminal of Indian Oil Corporation Limited, located in New Delhi, the Capital City of Republic of India. The terminal operates in 3 shifts and its activity involves receipt, storage and distribution of finished petroleum product (Motor Gasolene, Gas Oil and Aviation Fuel). The product is received from Mathura & Panipat Refineries through cross country pipelines. There is a provision to receive LDO & Aviation Fuel through Tank Wagons as well. For storage of various products, Delhi Terminal has 23 Storage Tanks. Delivery of product to various customers is undertaken through pipelines as well as Tank Lorries. The Terminal also handles Ethanol, which is mixed in a proportion of 10% by volume with Motor Gasoline for dispatches. At Bijwasan terminal product inlet is through Mathura Jalandhar pipeline which has commenced on 27 th April 1982 & is around 763 kms in length. This pipeline runs around 147 kms from Mathura to Delhi with a capacity of about 3.70 MMTPA. Storage capacity of terminal is KLs with 23 tanks storing different products. On an average 400 T/T were loaded per day with the help of TLF Gantry with 30 loading bays & 23 pumps for different products at the terminal The Terminal is operated in accordance with the provisions of licenses and consents granted by regulatory departments viz. Departments of Petroleum & Explosives Safety Organization, Directorate of Factories, Manufacture, Storage & Import of Hazardous Chemical Rules & Pollution Control Board etc. as per the applicable regulatory statutory acts and rules of Govt. of India Activities at Terminal Tank Lorry Loading - MS, HSD, SKO, ATF, LDO Tank Lorry Unloading : MS, 93 Octane, SKO, Ethanol Ethanol blending, at TLF Loading of additive to the additive tank and blending at TLF Pipeline Receipt through Cross Country Pipeline MS, HSD, SKO & ATF Receipt through Tank Wagon (Intermittent) ATF, LDO Inter tank transfer Tank Water Draining Operation Sampling of Product from Tank after every receipt Emptying out of Tank at fixed interval for Maintenance/ Cleaning for Quality Control adherence Opening of Strainers for Cleaning of Strainer s Filters at fixed interval. Maintenance and Repair of various Equipments Viz. Pumps, Motors, Fire Engines, Air Compressors etc. Process Flow Diagram of the operation at Terminal is enumerated as under:

8 Figure 3.1: Process Flow Diagram Ethanol blending process Nominate the ETHANOL Tank (TK-21 or TK-22) for MS- Ethanol blending at TLF. Nominate the ETHANOL Pump (E1 OR E2) for pumping ETHANOL to TLF through the nominated ETHANOL Tank (TK-21 or TK-22). Carry out gauging of the tanks and upload the gauges in SAP. Check line up of the nominated tanks & pumps or pump sequence for TLF Operation, by opening valves which are numbered for Operating sequence as below.

9 Figure 3.2: Ethanol blending process

10 Annexure 5: Copy of Consent to Operate

11

12

13

14 Annexure 6: Storage tank details S. No. Tank No. Material Physical State Hazard Involve Storage Capacity (KL) Type of Tank (CR/FR/UG /AG/SB) Height (m) Dia (m) Operating Condition Press Kg/Cm 2 Temp ºC 1 TK1 HSD Liquid Flammable CR M Atmospheric Ambient 2 TK2 HSD Liquid Flammable CR M Atmospheric Ambient 3 TK3 HSD Liquid Flammable CR M Atmospheric Ambient 4 TK4 MS Liquid Flammable FR M Atmospheric Ambient 5 TK5 MS Liquid Flammable FR M Atmospheric Ambient 6 TK6 SKO Liquid Flammable CR M 22 Atmospheric Ambient 7 TK7 LDO Liquid Flammable CR M 22 Atmospheric Ambient 8 TK8 HSD Liquid Flammable CR M 26 Atmospheric Ambient 9 TK9 ATF Liquid Flammable CR M 38 Atmospheric Ambient 10 TK10 ATF Liquid Flammable CR M 38 Atmospheric Ambient 11 TK11 MS Liquid Flammable FR M 24 Atmospheric Ambient 12 TK12 MS Liquid Flammable FR M 24 Atmospheric Ambient 13 TK13 ATF Liquid Flammable CR M 28 Atmospheric Ambient 14 TK14 ATF Liquid Flammable CR M 26 Atmospheric Ambient 15 TK15 ATF Liquid Flammable CR M 30 Atmospheric Ambient 16 TK16 SKO Liquid Flammable CR M 28 Atmospheric Ambient 17 TK17 SKO Liquid Flammable CR M 28 Atmospheric Ambient 18 TK18 EMPTY Liquid Flammable SB M(L) 3.75 Atmospheric Ambient 19 TK19 EMPTY Liquid Flammable SB M(L) 3.75 Atmospheric Ambient 20 TK20 93-OCTANE Liquid Flammable SB M(L) 3.75 Atmospheric Ambient 21 TK21 ETHANOL Liquid Flammable CR M 10 Atmospheric Ambient 22 TK22 ETHANOL Liquid Flammable CR 12.00M 10 Atmospheric Ambient 23 TK24 ATF Liquid Flammable CR M 20 Atmospheric Ambient

15 Annexure 7: Water consumption & Waste water generation details Water will be sourced through Tankers. As the terminal is providing only storage and handling services, there is no additional water requirement for processing or operation, water is required only for gardening and domestic purpose. Terminal s existing water requirement is 50 KLD. After addition of two new tanks, domestic water consumption will not increase. So after proposed expansion water consumption will remain same as 50 KLD. Table 0-3: Water Consumption Details S. No. Description Water Consumption in KLD Existing Additional Total 1 Processing Gardening Domestic Total There will not be any generation of industrial effluent. Domestic wastewater will be disposed off in soak pit through septic tank. Break up of wastewater generation along with disposal mode is given in following table Table 0-4: Wastewater Generation and disposal S. No. Description Wastewater Generation in KLD Existing Additional Total Disposal Mode 1 Industrial Operation Gardening Domestic Total To send to Septic Tank

16 Annexure 8: Fuel consumption details Table 0-5: Fuel Consumption details Sr. No. Stack Attached to Capacity Stack Nos. Type of Fuel used Fuel consumption Existing 1 DG set 2 x 750 KVA + 1 x 500 KVA 5 HSD 140 Ltr/hr. at full load 2 Fire water Engine pumps 8 x 616 m 3 8 HSD 35 Ltr/hr. at full load Additional No flue gas stack will be added after additional tankage

17 Annexure 9: Hazardous waste generation details Table 0-6: Hazardous waste Generation and disposal S. No. Hazardous Waste Hazardous Waste Category Quantity in MTPA Existing Proposed Total 1 Used Oil liters liters 2 Tank cleaning Sludge Management Disposed to authorized agency Internal Bio- remedial

18 Annexure 10: Stack details Table 0-7: Stack details Sr. No. 1 2 Stack Attached to Capacity Stack Nos. DG set As a backup during emergency Fire water Engine pumps Existing Stack Height, m Stack Top Dia, m 2 X 750 KVA inch 1 X 500 KVA inch 8 X 616 m inch Proposed No flue gas stack will be added after proposed expansion

19 Annexure 11: Land possession documents

20

21

22

23

24

25

26

27

28

29

30

31