SSENTIALS RESTEK. Must-Have Solutions for Your Lab Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility

Size: px
Start display at page:

Download "SSENTIALS RESTEK. Must-Have Solutions for Your Lab Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility"

Transcription

1 RESTEK SSENTIALS Must-Have Solutions for Your Lab Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility ALSO IN THIS ISSUE: Raptor Columns: Biphenyl & ARC-18 Sky Inlet Liners: 100% Guaranteed MegaMix CRMs for Soil and Water Innovative Chromatography Solutions

2 People rely on you for fast, accurate data. Rely on Rxi columns to deliver it. Your instrument needs to run, it needs to run now, and it needs to give you the right results the first time. Ground-breaking Rxi 3-in-1 technology unifies outstanding inertness, low bleed, and high reproducibility into a single high-performance column line that gives you the foundational low-level accuracy you need. Outstanding Inertness Our 3-in-1 technology produces such inert columns we name them Restek extreme Inertness (Rxi ). Extreme inertness improves signal-to-noise ratios and heightens sensitivity to lower detection limits while generating consistent peak shapes and retention times. Rxi inertness gives you predictable retention times, good peak shapes, and easy, accurate integration. 5 ng, 2.2 min A: Pyridine on non-rxi column 5 ng, 2.39 min B: Pyridine on Rxi column 2.5 ng, 2.8 min 1 ng, 2.32 min 1 ng, 2.40 min 0.5 ng, 2.41 min Time (min) Time (min)

3 Low Bleed Rxi columns are more stable, so even at higher temperatures, they generate less bleed and reduce background to further improve signal-to-noise ratios, enhance sensitivity, and lower detection limits. Improve sensitivity and accuracy at trace levels with low-bleed Rxi columns Reference Peak 1 ng tridecane 350 C Column A pa 330 C Column B Column C Column D Column E Column F Rxi -5ms Time (min) GC_EV00822 Comparison of 30 m x 0.25 mm ID, 0.25 µm 5%-diphenyl columns at 330 C through 350 C; hydrogen carrier gas; flame ionization detection. High Reproducibility Unmatched manufacturing precision and stringent quality control mean that every Rxi column performs the same way as the column it replaces, every time. We exceed industry standards for efficiency, retention, bleed, and inertness. Choose Rxi columns to ensure column-to-column and lot-to-lot reproducibility. Column Batch #1 Column Batch #2 Column Batch #3 Peaks 1. 1,6-Hexanediol 2. 4-Chlorophenol 3. Methyl nonanoate 4. 1-Decylamine 5. Tridecane 6. 1-Undecanol 7. Acenaphthylene 8. Pentadecane GC_EV00819 Column: Rxi -5ms, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13423); Sample: 500 µg/ml Isothermal Column Test Mix in toluene; Inj.: 1.0 µl, split injection (split ratio 1:100), 4mm single gooseneck inlet liner with wool (cat.# 22405); Inj. temp.: 250 C; Carrier gas: hydrogen, constant flow; Linear velocity: C; Oven temp.: 135 C; Det.: 330 C

4 Optimized Efficiency and Selectivity Rxi columns also feature the efficiency to generate sharp, narrow peaks, so target analytes are still separated at high temperatures. When coupled with the right selectivity, this efficiency lets you perform analyses much faster without losing resolution. Higher efficiency (i.e., more plates per meter) means better separations on an Rxi column. Non-Restek N=3,900 plates/meter Restek Rxi Technology N=4,270 plates/meter N=4,270 plates/meter The Rxi column line spans the polarity range, so you can easily select the perfect selectivity to help you run faster and produce unbeatable results. Rxi columns are available in a wide range of polarities. Rxi -1ms Rxi -1HT Rxi -5ms Rxi -5Sil MS Rxi -5HT Rxi -XLB Rxi -624Sil MS Rxi -35Sil MS Rxi -PAH Rxi -17 Rxi -17Sil MS NON-POLAR P O L A R I T Y POLAR + Put Rxi Columns to Work in Your Lab Today With so much riding on what you do, you owe it to yourself to put the best GC column into your instrument. Visit to learn more about Rxi columns and order yours today! Learn more at

5 Dynamic Duo Restek s Leak Detector and ProFLOW 6000 Flowmeter An Unbeatable Combination Purchase them together and SAVE! Protect your instrument and improve data quality with this powerful pair from Restek. Checking for leaks and verifying flows before you start helps you avoid costly problems later. Description qty. cat.# Dynamic Duo Combo Pack (Restek Leak Detector and ProFLOW 6000 Flowmeter) kit Related Products and Accessories Leak Detector With Hard-Sided Carrying Case and Universal Charger Set (U.S., UK, European, Australian) ea Small Probe Adaptor for Leak Detector ea Restek ProFLOW 6000 Electronic Flowmeter With Hard-Sided Carrying Case ea Soft-Sided Storage Case for Leak Detector or ProFLOW 6000 Flowmeter ea learn more at

6 True Blue Performance Satisfaction Guaranteed * Exceptionally inert Sky inlet liners with state-of-the-art deactivation improve trace-level analysis and now come with a 100% satisfaction guarantee! Increase accuracy and precision by preventing loss of sensitive analytes even when using wool. Achieve lower detection limits for a wide range of active compounds. Ensure liner-to-liner reproducibility through consistent manufacturing and extensive testing. 100% customer satisfaction if a liner doesn't perform to expectations, we will replace it or credit your account.* In stock now order today at Sky inlet liners are available in 1-, 5-, and 25-packs for most common GCs: Agilent Bruker/Varian PerkinElmer Shimadzu Thermo Scientific Patent pending * 100% SATISFACTION GUARANTEE: If your Sky inlet liner does not perform to your expectations for any reason, simply contact Restek Technical Service or your local Restek representative and provide a sample chromatogram showing the problem. If our GC experts are not able to quickly and completely resolve the issue to your satisfaction, you will be given an account credit or replacement product (same cat.#) along with instructions for returning any unopened product. (Do not return product prior to receiving authorization.) For additional details about Restek's return policy, visit learn more and view the full Sky line at

7 SPP speed. USLC Resolution. A New Species of Column Restek is excited to announce the evolution of superficially porous particles with the introduction of Raptor LC columns and guards. Superficially porous particles (commonly referred to as SPP or core-shell particles) changed the world of LC by dramatically boosting column efficiency and reducing analysis times, but they were only the beginning. With Raptor LC columns, Restek chemists have combined the speed of SPP with the resolution of highly selective USLC technology. This new species of chromatographic column allows you to more easily achieve peak separation and faster analysis times without expensive UHPLC instrumentation. Higher efficiency for drastically faster analysis times. Better selectivity for substantially improved resolution. Increased sample throughput with existing HPLC instrumentation. Coming soon: 5 µm particles and a full suite of phases! Put Raptor LC columns and guards to the test on your most challenging workflows! Learn more and order today at Dissecting the Raptor LC Column Larger 2 μm Frit Prevents clogging better than commonly used 0.5 μm frits; boosts column lifetime and helps maintain optimal pressures. Rugged Label Clearly identifies both flow direction and column; resists solvents and tearing to last as long as your column does. Proprietary Column- Packing Technique Provides greater pressure stability (8,700+ psi / 600+ bar); achieves higher linear velocities without sacrificing efficiency or lifetime. Raptor SPP Particles Robust 2.7 μm Particles Let you run high-speed analyses without UHPLC. Narrow Silica Distribution Ensures high efficiency and consistent flows. Updated Bonding and QC Guarantee retention time stability, run to run and column to column.

8 Time-Tested Restek Biphenyl Phase: The established choice for bioanalytical testing since 2005 Separates compounds that other phenyl and C18 chemistries can t. Allows the use of simple, MS-friendly mobile phases. CH 3 Si CH 3 O Restek s most popular LC phase (also available on fully porous silica). Length 2.1 mm 3.0 mm 4.6 mm 30 mm 9309A A3E 9309A35 50 mm 9309A A5E 9309A mm 9309A A1E 9309A mm 9309A A6E 9309A65 Acid-Resistant Restek ARC-18 Phase: Ahead of the curve for large, multiclass lists by mass spec Well-balanced retention profile. Endures low-ph mobile phases without sacrificing retention or peak quality. Si O Length 2.1 mm 3.0 mm 4.6 mm 30 mm 9314A A3E 9314A35 50 mm 9314A A5E 9314A mm 9314A A1E 9314A mm 9314A A6E 9314A65 Raptor EXP Guard Columns Protect your investment and extend the life of our already-rugged LC columns with patent-pending guard column hardware developed by Optimize Technologies. A Restek LC guard cartridge in an EXP direct connect holder is the ultimate in column protection. Experience Selectivity Accelerated

9 Streamline Your Prep and Calibration for Faster Water and Soil Analysis MegaMix Certified Reference Materials Maximized number of target analytes in a single ampul. Formulated and packaged for maximum stability. Manufactured and tested in our ISO-accredited labs to satisfy requirements for CRMs. Two independently produced lots in inventory for most mixes MegaMix Standard (54 components) 200 µg/ml each in P&T methanol, 1 ml/ampul cat.#30432 (ea.) 2,000 µg/ml each in P&T methanol, 1 ml/ampul cat.#30431 (ea.) Volatiles MegaMix Standard With Gases (60 components) 200 µg/ml each in P&T methanol, 1 ml/ampul cat.# (ea.) Drinking Water VOA MegaMix Standard, Rev. 4.1 (73 components) 2,000 µg/ml each in P&T methanol, 1 ml/ampul cat.# (ea.) VOA MegaMix Standard (69 components) 2,000 µg/ml each in P&T methanol, 1 ml/ampul cat.# (ea.) Volatiles MegaMix Standard, EPA Method 624 (26 components) 2,000 µg/ml each in P&T methanol, 1 ml/ampul cat.# (ea.) Semivolatiles MegaMix Standard, EPA Method 625 (54 components) 1,000 µg/ml each in methylene chloride, 1 ml/ampul cat.# (ea.) 8260B MegaMix Calibration Mix (76 components) 2,000 µg/ml each in P&T methanol, 1 ml/ampul cat.# (ea.) 8270 MegaMix Standard (76 components) 1,000 µg/ml each in methylene chloride, 1 ml/ampul* cat.# (ea.) To view full compound lists and order yours, visit Meet 2nd Source Gas Standard Requirements With 1 Order Restek features a wide selection of air monitoring gas calibration standards. Each mix is independently manufactured by both Spectra/Linde and Scott/Air Liquide (Pi-marked for EU regulations), so you can purchase from 2 separate sources with the convenience of placing 1 order! Choose the following cylinders: TO-14A TO-15 Natural Gases Massachusetts APH Sulfurs Ozone Precursor/PAMS Refinery Gases Japan Calibration Order your custom gas standards from Restek, too! Go to for a quote. For more details, ordering information, and full component lists, go to

10 Solid Phase Extraction Cartridges Proven Quality Superior Cleanliness Method-Specific Performance Available with the following sorbents: Silica: Multipurpose EPH Silica: Petroleum Florisil Adsorbent: Pesticides CarboPrep Adsorbent: Dirty Samples FREE samples available! Contact us or your local Restek representative. Learn more at Need help choosing the right GC column? Visit for a custom recommendation! Lit. Cat.# GNES1979-UNV 2014 Restek Corporation. All rights reserved. Printed in the U.S.A.