1 Air Force MILCON Sustainability Requirements Scoresheet version LEED 2009 (Updated September 203) * required entry General Information XXXX23456 Project ID (e.g. ABCD2345) xxxxxxxxxxxxxxxxxx Real Property Unique ID (RPUID) Corrosion Control/Fuel Cell (CC/FC Hangar) Building Name New Building Construction Project Type Other Installation Other City * Other State * Other CONUS * Air Combat Command MAJCOM TBD PM Name $0.00 PA ($k) 77,933 Building Size (SF) 205 Program Year (FY####) Federal Requirements Complete Initial Design Charrette Project Phase 205 Design Started (FY####) 0/9/207 BOD (MM/DD/YY) In Progress Pursuing formal LEED Certification Date Project Registered (MM/DD/YY) Date Project Certified by GBCI (MM/DD/YY) LEED Points Awarded by GBCI (e.g. 42) LEED Energy and Water Points Awarded by GBCI LEED Certification Level Awarded by GBCI Fees ($) Registration Certification LEED 2009 LEED Rating System 4 LEED Points Status Certified LEED Certification Level Status 7 LEED Energy and Water Points Status 9% HPSB Compliant 30% Energy Efficiency Achieved (% below ANSI/ASHRAE/IESNA Standard ) 3/3/205 Date Scoresheet Completed or Revised * 203_V0 Scoresheet version Color Coding: See Instructions Tab for more detail Drop-Down Box No Entry Required Custom Entry Recommended (not required) Yes or N/A Maybe LEED Prerequisite No * required entry Federal Requirements for High Performance and Sustainable Buildings (HPSB) & UFC HPSB I: Employ Integrated Design Principles (UFC para 2-2) Total Points 2 Possible Points 2 Yes HPSB I. Integrated Design * Yes HPSB I.2 Commissioning * UFC para 2-3. Promote Sustainable Location and Site Development Total Points 0 Possible Points (HPSB only) Maybe UFC para 2-3. Site selection * Maybe UFC para Mitigation of Heat Island Effect * Yes UFC para Reduction of Light Pollution * Maybe HPSB III.3-4 Stormwater Management * 4/20/205

2 Air Force MILCON Sustainability Requirements Scoresheet version LEED 2009 (Updated September 203) * required entry HPSB II: Optimize Energy Performance (UFC para 2-4) Total Points 4 Possible Points 4 Yes HPSB II. Energy Efficiency Yes Reduce energy use 30% below ANSI/ASHRAE/IESNA Standard or if not - achieve maximum energy efficiency that is * lifecycle cost effective 30.0% Insert percentage below ANSI/ASHRAE/IESNA Standard in terms of energy use (e.g. 32) 0 Insert building energy intensity (kbtu/yr-sqft) calculated IAW 0 CFR 433 Yes HPSB II.2 On-site Renewable Energy - Solar Hot Water Heater System Yes Installed solar hot water heater system or found installation not lifecycle cost effective * 0.0 Insert generation capacity (MMBtu/yr) 0.0% Insert percentage of demand Yes HPSB II.3 On-site Renewable Energy Yes Installed renewable energy elements or projects were not lifecycle cost effective * 0 Renewable energy types (check below) * Solar PV Geothermal Hydro Waste to Energy 0.0 Insert generation capacity (kw) 0.0% Insert percentage of total building Yes HPSB II.4 Measurement and Verification Yes Water Metering: Select N/A if no service * Yes Electric Metering: Select N/A if no service * Yes Natural Gas Metering: Select N/A if no service * N/A Steam Metering: Select N/A if no service HPSB III: Protect and Conserve Water (UFC para 2-5) Total Points 3 Possible Points 3 Yes HPSB III. Indoor Water * Yes HPSB III.2 Outdoor Water * Yes HPSB III.4 Water used for heating and cooling Yes Water efficient measures were implemented with heating and cooling equipment when life cycle effective * HPSB IV: Enhance Indoor Environmental Quality (UFC para 2-6) Total Points 5 Possible Points 6 Yes HPSB IV. Thermal Comfort * Yes HPSB IV.2 Ventilation * Yes HPSB IV.3 Moisture Control * Maybe HPSB IV.4 Daylighting * Yes HPSB IV.5 Low Emitting Materials * Yes HPSB IV.6 Protect Indoor Air Quality during Construction * Yes HPSB IV.7 Environmental Tobacco Smoke * HPSB V: Reduce Environmental Impact of Materials (UFC para 2-6) Total Points 6 Possible Points 6 Yes HPSB V. Recycled Content * Yes HPSB V.2 Biologically-based Products * Yes HPSB V.3 Environmentally Preferable Products * Yes HPSB V.4 Waste and Materials Management - Recycling * Yes HPSB V.5 Waste and Materials Management - Divert 50% from Disposal 50.0% Insert percentage diverted from landfill * Data element is not applicable * Yes HPSB V.6 Ozone Depleting Substances * HPSB Totals Possible Points Federal Requirements - Yes or N/A 2 Federal Requirements - Maybe 0 Federal Requirements - No 9% Percentage of Federal Requirements Met Solar CP Solar Thermal Electric GSHP Wind Renewables were not 4/20/205 2

3 Air Force MILCON Sustainability Requirements Scoresheet version LEED 2009 (Updated September 203) LEED 2009 Checklist LEED Credits and/or Prerequisites that meet HPSB/UFC Requirements LEED Credits and/or Prerequisites that align closely with HPSB/UFC Requirements LEED Credits that meet USAF Energy & Water Criteria (may depend on technologies & strategies) * required entry Sustainable Sites Achievable Points 7 Sustainable Sites Possible Points 26 Yes Prereq Construction Activity Pollution Prevention (HPSB GP3) Required Maybe Credit Site Selection Maybe Credit 2 Development Density & Community Connectivity 5 Maybe Credit 3 Brownfield Redevelopment Maybe Credit 4. Alternative Transportation - Public Transportation Access 6 Yes Credit 4.2 Alternative Transportation - Bicycle Storage & Changing Rooms Yes Credit 4.3 Alternative Transportation - Low-Emitting & Fuel Efficient Vehicles 3 Yes Credit 4.4 Alternative Transportation - Parking Capacity 2 Maybe Credit 5. Site Development - Protect or Restore Habitat Maybe Credit 5.2 Site Development - Maximize Open Space Maybe Credit 6. Stormwater Design - Quantity Control (HPSB GP3) Maybe Credit 6.2 Stormwater Design - Quality Control (HPSB GP3) Maybe Credit 7. Heat Island Effect - Non-Roof (UFC) Maybe Credit 7.2 Heat Island Effect - Roof (UFC) Yes Credit 8 Light Pollution Reduction Select which LEED Interior Lighting Option was used Water Efficiency Achievable Points 7 Possible Points 0 Yes Prereq Water Use Reduction - 20% Reduction (HPSB GP3) Required 4 Credit Water Efficient Landscaping (HPSB GP3) 2 to 4 2 Reduce Potable Water Use by 50% (HPSB GP3) 2 4 No Potable Use or Irrigation (HPSB GP3) 2 No Credit 2 Innovative Wastewater Technologies 2 3 Credit 3 Water Use Reduction (HPSB GP3) 2 to % Reduction (HPSB GP3) % Reduction (HPSB GP3) 4 40% Reduction (HPSB GP3) Energy & Atmosphere Achievable Points Possible Points 35 Yes Prereq Fundamental Commissioning of the Building Energy Systems (HPSB GP) Required Yes Prereq 2 Minimum Energy Performance (HPSB GP2) Required Yes Prereq 3 Fundamental Refrigerant Management (HPSB GP5) Required 7 Credit Optimize Energy Performance (HPSB GP2) to 9 2% for New Buildings/8% for Existing Building Renovations 2 4% for New Buildings/0% for Existing Building Renovations 3 6% for New Buildings/2% for Existing Building Renovations 4 8% for New Buildings/4% for Existing Building Renovations 5 20% for New Buildings/6% for Existing Building Renovations 6 22% for New Buildings/8% for Existing Building Renovations 7 24% for New Buildings/20% for Existing Building Renovations 8 26% for New Buildings/22% for Existing Building Renovations 9 28% for New Buildings/24% for Existing Building Renovations 0 30% for New Buildings/26% for Existing Building Renovations 32% for New Buildings/28% for Existing Building Renovations 2 34% for New Buildings/30% for Existing Building Renovations 3 36% for New Buildings/32% for Existing Building Renovations 4 38% for New Buildings/34% for Existing Building Renovations 5 40% for New Buildings/36% for Existing Building Renovations 6 42% for New Buildings/38% for Existing Building Renovations 7 44% for New Buildings/40% for Existing Building Renovations 8 46% for New Buildings/42% for Existing Building Renovations 9 48%+ for New Buildings/44%+ for Existing Building Renovations 0 Credit 2 On-Site Renewable Energy (HPSB GP2) to 7 On-site % 2 On-site 3% 3 On-site 5% 4 On-site 7% 5 On-site 9% 6 On-site % 7 On-site 3% Yes Credit 3 Enhanced Commissioning (HPSB GP) 2 Yes Credit 4 Enhanced Refrigerant Management (HPSB GP5) 2 Maybe Credit 5 Measurement & Verification (HPSB GP2) 3 Maybe Credit 6 Green Power 2 4/20/205 3

4 Air Force MILCON Sustainability Requirements Scoresheet version LEED 2009 (Updated September 203) * required entry Materials & Resources Achievable Points 6 Possible Points 4 Yes Prereq Storage & Collection of Recyclables (HPSB GP5) Required 0 Credit. Building Reuse - Maintain Existing Walls Floors & Roof to 3 Maintain 55% of Existing Walls Floors & Roof 2 Maintain 75% of Existing Walls Floors & Roof 3 Maintain 95% of Existing Walls Floors & Roof Maybe Credit.2 Building Reuse - Maintain 50% of Interior Non-Structural Elements 0 Credit 2 Construction Waste Management (HPSB GP5) to 2 50% Recycled or Salvaged 2 75% Recycled or Salvaged 0 Credit 3 Materials Reuse to 2 5% of value of material reused content 2 0% of value of material reused content 2 Credit 4 Recycled Content (HPSB GP5) to 2 0% of value of material recycled content 2 20% of value of material reused content 2 Credit 5 Regional Materials to 2 0% Extracted, Processed & Manufactured 2 20% Extracted, Processed & Manufactured Yes Credit 6 Rapidly Renewable Materials (HPSB GP5) Yes Credit 7 Certified Wood (HPSB GP5) Indoor Environmental Quality Achievable Points 0 Possible Points 5 Yes Prereq Minimum IAQ Performance (HPSB GP4) Required Yes Prereq 2 Environmental Tobacco Smoke (ETS) Control (HPSB GP4) Required Yes Credit Outside Air Delivery Monitoring Maybe Credit 2 Increased Ventilation Yes Credit 3. Construction IAQ Management Plan, During Construction (HPSB GP4) Yes Credit 3.2 Construction IAQ Management Plan, Before Occupancy (HPSB GP4) Yes Credit 4. Low Emitting Materials, Adhesives & Sealants (HPSB GP4) Yes Credit 4.2 Low Emitting Materials, Paints & Coatings (HPSB GP4) Yes Credit 4.3 Low Emitting Materials, Flooring Systems (HPSB GP4) Yes Credit 4.4 Low Emitting Materials, Composite Wood & Agrifiber Products (HPSB GP4) Yes Credit 5 Indoor Chemical & Pollutant Source Control Yes Credit 6. Controllability of Systems, Lighting (HPSB GP4) Maybe Credit 6.2 Controllability of Systems, Thermal Comfort Yes Credit 7. Thermal Comfort, Design (HPSB GP4) Maybe Credit 7.2 Thermal Comfort, Verification Maybe Credit 8. Daylight & Views - Daylight 75% of Spaces (HPSB GP4) Maybe Credit 8.2 Daylight & Views - Views for 90% of Spaces Innovation & Design Process Achievable Points 0 Possible Points 6 Credit. Innovation in Design. Select if ID. was for energy and/or water Credit.2 Innovation in Design.2 Select if ID.2 was for energy and/or water Credit.3 Innovation in Design.3 Select if ID.3 was for energy and/or water Credit.4 Innovation in Design.4 Select if ID.4 was for energy and/or water Credit.5 Innovation in Design.5 Select if ID.5 was for energy and/or water Credit 2 LEED Accredited Professional Regional Priority Credits Achievable Points 0 Possible Points 4 Credit. Regional Priority. Select if RP. was for energy and/or water Credit.2 Regional Priority.2 Select if RP.2 was for energy and/or water Credit.3 Regional Priority.3 Select if RP.3 was for energy and/or water Credit.4 Regional Priority.4 Select if RP.4 was for energy and/or water LEED Project Totals (pre-certification estimates) Possible Points 0 4 Total LEED Yes Points 8 Total LEED Maybe Points Total LEED No Points 7 Total LEED Energy and Water Related Points Certified LEED Certification Status N/A LEED Horizontal Benchmark Level Horizontal N/A N/A LEED Utility Benchmark Level Utilities N/A N/A LEED Industrial Benchmark Level Industrial N/A LEED : Certified: points, Silver: points, Gold: points, Platinum: /20/205 4

5 High Performance Sustainable Building Requirements, UFC , and LEED 2009 References For more information on LEED Credits that meet or align closely with federal requirements as well as other credits a building can pursue towards the Silver certification level, review the LEED New Construction and Major Renovations 2009 Rating System Color Code LEED Credits and/or Prerequisites that align closely with Federal High Performance Sustainable Buildings (HPSB) Requirements These credits and/or prerequisites align closely with the associated HPSB Guiding Principle. They could be either more or less stringent or have different measurement metrics. In the case where one is more stringent than the other, achieving the more stringent one does not imply the less stringent is achieved. LEED Credits and/or Prerequisites that meet Federal High Performance Sustainable Buildings (HPSB) Requirements These credits and/or prerequisites have the same requirements as the associated HPSB Guiding Principle. This does not guarantee achieving the LEED Credit, as some documentation methods may vary. References EO 3423 High Performance Sustainable Building Guidance (Dec 08) LEED(R) for New Construction & Major Renovations Nov 2008 Integrated Design HPSB I. UFC para 2-2. HPSB I: Employ Integrated Design Principles Use a collaborative, integrated planning and design team, composed of user, government support staff, and appropriate professionals, to identify requirements and to establish performance goals for siting, energy, water, materials, indoor environmental quality, and other comprehensive design goals. Ensure incorporation of these goals throughout the design and lifecycle of the building, including deconstruction. Site attributes, including climate and local and regional context, impact the design of the building. Evaluate the site and building components to determine whether passive and natural design strategies and features are cost effectively incorporated before the active and mechanical systems are designed. Use the following sequential approach: Analyze potential sites and associated climate including local and regional context. Select a sustainable site. Design building to site analysis focusing on orientation, configuration and massing. Select and integrate into the design, high performance and sustainable building envelope strategies and components (e.g. roofs, walls, fenestrations). Select, design and integrate into the overall design, high performance and sustainable systems (e.g. HVAC, plumbing, water heating systems, lighting systems, control systems, elevators, and fire protection systems). Incorporate integrated design as described in ASHRAE 89. Informative Appendix H (Integrated Design). Follow the steps of design optimization, as applicable, in ASHRAE 89. Section H.. (Charrette Process). Requirement Source Document(s) Executive Order 3423 and 354 LEED Credit(s) meet None Commissioning HPSB I.2 UFC para Employ commissioning practices appropriate to the size and complexity of the building and its system components in order to verify performance and ensure that design requirements are met. This must include an experienced commissioning provider. The use of contracted services or Government personnel as the commissioning provider will be determined at project level. Meet the requirements of ASHRAE 89. Section (Building Project Commissioning), with the following modifications: For buildings and systems that are less complex, commissioning can be tailored as determined by the DoD Component AHJ. For Air Force projects, the Project Delivery Team must determine the level of commissioning activities required. Schematic design is the design charrette or similar conceptual design activity. Delete the requirement to meet ASHRAE 55 Section 6.2 (Documentation). Requirement Source Document(s) Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED EA Prerequisite : Fundamental Commissioning of Building Energy Systems LEED EA Credit 3: Enhanced Commissioning LEED Credit(s) meet None 5

6 High Performance Sustainable Building Requirements, UFC , and LEED 2009 References UFC , 2-3. Promote Sustainable Location and Site Development Site selection UFC para 2-3. Meet the requirements in UFC and UFC During the site selection process, give preference to sites which posses the following characteristics when appropriate: Adaptive reuse or renovation of buildings or sites (including historic buildings), or use of previously disturbed/developed areas Building orientation to maximize energy efficiency, passive solar and daylighting potential of the building Locations in central business districts (cantonment areas) and rural town centers (remote locations) Sites well served by public or other transit if available or projected to be available Site design elements that ensure safe and convenient pedestrian access Proximity to housing Avoiding development of sensitive land resources (including greenfields and USDA Prime Farmland as defined in 7 USC 420) Consult with local Cultural Resource Manager to identify potential impacts to existing historic buildings, districts, or view sheds Parking management strategies to encourage co-use of shared parking Requirement Source Document(s) UFC para 2-3. LEED Credit(s) aligns closely with LEED SS Credits -5 (Site Selection, Development Density and Community Connectivity, Brownfield Redevelopment, Alternative Transportation, Site Development) LEED Credit(s) meet None Mitigation of Heat Island Effect UFC para For Site Hardscapes Meet the requirements in ASHRAE 89. Section (Site Hardscape) for sidewalks, courtyards and POV parking areas. For all other site hardscapes, implement to the maximum extent practical. The use of Section (e) is not allowed. For Walls Meet the requirements in ASHRAE 89. Section (Walls). For Roofs Meet the requirements in UFC Requirement Source Document(s) UFC para LEED Credit(s) aligns closely with LEED SS Credits 7. and 7.2: Heat Island Effect Roof and Non-Roof LEED Credit(s) meet None Reduction of Light Pollution Meet the requirements of UFC UFC para Requirement Source Document(s) UFC LEED Credit(s) meet LEED SS - Credit 8: Light Pollution Reduction Stormwater Management HPSB III.3-4 UFC para Requirement Source Document(s): EISA 2007 Sec 438 Meet the requirements of UFC Employ design and construction strategies that reduce storm water runoff and discharges of polluted water offsite. Per EISA Section 438, to the maximum extent technically feasible, maintain or restore the predevelopment hydrology of the site with regard to temperature, rate, volume, and duration of flow using site planning, design, construction, and maintenance strategies. This question includes both construction storm water discharge controls and stormwater design. LEED Credit(s) aligns closely with LEED SS Credit 6.: Stormwater Design - Quantity Control LEED SS Credit 6.2: Stormwater Design - Quality Control LEED Credit(s) meet LEED SS Prerequisite : Construction Activity Pollution Prevention 6

7 High Performance Sustainable Building Requirements, UFC , and LEED 2009 References HPSB II: Optimize Energy Performance (UFC , 2.4) Energy Efficiency Design the building to achieve at least 30% energy consumption reduction from ASHRAE 90. (2007) baseline or 2% energy HPSB II. consumption reduction from ASHRAE 90. (200) baseline. For Navy and Air Force projects, use ASHRAE 90. (2007) baseline, UFC para 2-4. except for the performance rating formula in G.2, which should be used as follows (from 0 CFR 433.5): Requirement Source Document(s) 0 CFR 433, EPAct 05 Percentage improvement = 00 x (Baseline building consumption Proposed building consumption) (Baseline building consumption Receptacle and process loads). This differs from the LEED calculation. Note: The Scoresheet assumes that any project with a design date after 203 will be based on ASHRAE 90. (200). Design Federal low-rise residential buildings to achieve at least 30% energy consumption reduction from International Energy Conservation Code (IECC) baseline. If a 30% reduction is not life-cycle cost-effective, the design of the proposed building must be modified so as to achieve an energy consumption level at or better than the maximum level of energy efficiency that is life-cycle cost-effective. LEED Credit(s) aligns closely with LEED EA Prerequisite 2: Minimum Energy Performance LEED EA Credit : Optimize Energy Performance LEED Credit(s) meet None On-site Renewable Energy - Solar Per the Energy Independence and Security Act (EISA) Section 523, meet at least 30% of the hot water demand through the installation Hot Water Heater System of solar hot water heaters, when lifecycle cost effective. HPSB II.3 UFC para Requirement Source Document(s): EISA Sec. 523 LEED Credit(s) aligns closely with LEED EA Credit 2: On-Site Renewable Energy LEED Credit(s) meet None On-site Renewable Energy HPSB II.4 UFC para Provide on-site renewable energy systems in accordance with ASHRAE 89. Section (On-Site Renewable Energy Systems) where life-cycle cost effective considering climate, infrastructure condition, mission compatibility, and effects on base wide electrical system (grid) power quality. Exception: Purchase of renewable energy certificates (RECs) must not be used as a substitute for the Section new building requirement. When renewable systems are provided, comply with IEEE 547 for renewable systems interface to the electrical system grid. Note: The IEEE 547 Series of Interconnection Standards are available from IEEE ( as design guides for IEEE 547 implementation. Designs must include the following requirements in order to limit the risk to energy security: a. Direct interconnection of system to installation-wide electrical system (grid): For renewable systems that include a tie-in by a direct connection to the primary distribution system, provide a cumulative renewable load analysis of both the direct connection and building renewable power systems. Evaluate the proposed systems and verify there are no adverse effects on the installation-wide electrical system frequency control, voltage regulation and power quality. See Appendix B for issues that should be considered. b. Direct interconnection of system to buildings that utilize engine generators that may operate in parallel with the renewable energy generation: Evaluate the proposed systems and verify there are no adverse effects on the generator s ability to maintain frequency control, voltage regulation and power quality. See Appendix B for issues that should be considered. If the stability of the combined systems cannot be confirmed, then design system to automatically disconnect renewable power generation when the backup generator is in operation. c. Direct interconnection of system to buildings that either do not utilize engine generators or have backup power systems that would never operate in parallel with the renewable energy generation, such as a backup generator supplying power via an automatic transfer switch: Provide analysis validating that electrical system design address the electrical characteristics (real and reactive power output) of the renewable system. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED EA Credit 2: On-Site Renewable Energy LEED Credit(s) meet None 7

8 High Performance Sustainable Building Requirements, UFC , and LEED 2009 References Measurement and Verification HPSB II.5 UFC para and A utility meter must be installed at each building, for each utility serving the building (e.g. district steam, district hot and chilled water, electricity, natural gas, fuel oil, etc.) in the normal units of the measure (i.e. kwh, kw, cf, gallons, etc.). Meters must be connected to a base wide energy and utility monitoring and control system using the installation s advanced metering protocols. The installation of meters is required per DODI 470., Installation Energy Management. Implement submetering when authorized in writing by the Installation. Utilize ASHRAE 89. Section (Energy Consumption Management) as guide for subsystem implementation. Install water meters to monitor use in buildings consuming indoor and outdoor water as required by DODI The installation of separate water meters for locations with outdoor water use is encouraged. Requirement Source Document(s): EPAct 2005 Section 03, EISA 2007 Section 434 Links Energy Policy Act of 2005 LEED Credit(s) aligns closely with LEED EA Credit 5: Measurement and Verification LEED Credit(s) meet None Indoor Water HPSB III. UFC para 2-5. HPSB III: Protect and Conserve Water Meet the requirements of ASHRAE 89. Section (Plumbing Fixtures and Fittings). Water closet replacements in major renovations may have a flush value of up to.6 GPF (6. LPF) to accommodate existing plumbing capacity. Specify EPA WaterSense-labeled products, where appropriate and available. Meet the requirements of ASHRAE 89. Section (Appliances). Requirement Source Document(s): EPAct 992 LEED Credit(s) aligns closely with LEED WE Credit 3: Water Use Reduction - Reduce by 30% (3.), 35% (3.2), 40% (3.3) LEED Credit(s) meet LEED WE Prerequisite : Water Use Reduction - 20% Reduction Outdoor Water HPSB III.2 UFC para Use water efficient landscape and irrigation strategies, such as water reuse, xeriscaping and the use of harvested rainwater, to reduce outdoor potable water consumption by a minimum of 50%. This requirement must be demonstrated by comparison to a baseline building using the EPA WaterSense landscape water budget tool version.0 or later, or a Component approved tool. Meet the requirements of UFC and the following requirements of ASHRAE 89. when life cycle cost effective: Section 6.3. (Mandatory Provisions: Site Water Use Reduction) and either Section 6.4. (Prescriptive Option: Site Water Use Reduction) or Section 6.5. (Performance Option: Site Water Use Reduction). Show preference for irrigation contractors who are certified through a WaterSense labeled program. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED WE Credit.2: Water Efficient Landscaping - No Potable Water Use or Irrigation LEED Credit(s) meet LEED WE Credit.: Water Efficient Landscaping - Reduce by 50% Water Used for Heating and Cooling HPSB III.4 UFC para Meet the requirements of the following sections of ASHRAE 89. when life cycle cost effective. Meet the requirements of Sections (a) and (b) (HVAC Systems and Equipment). Section (c) (HVAC Systems and Equipment). Condensate collection is not required if there is no practical use for the collected condensate. Section (Cooling Towers). Requirement Source Document(s): EPAct 2005, Sec. 09 LEED Credit(s) aligns closely with None LEED Credit(s) meet None Per EPAct 2005 Section 09, when potable water is used to improve a building s energy efficiency, implement lifecycle cost effective water conservation measures. 8

9 High Performance Sustainable Building Requirements, UFC , and LEED 2009 References HPSB IV: Enhance Indoor Environmental Quality (UFC , 2-6) Thermal Comfort HPSB IV. UFC para 2-6. Meet the requirements of ASHRAE 89. Section (Thermal Environmental Conditions for Human Occupancy). Documentation as described in ASHRAE 55 Section 6.2 is not required. Compliance with standards by providing passive (non-mechanical) thermal comfort methods are allowed and encouraged as described in paragraph 2-2. in the UFC. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) meet LEED EQ Credit 7: Thermal Comfort - Design Ventilation Meet the requirements of ASHRAE 89. Section 8.3. (Indoor Air Quality). HPSB IV.2 UFC para 2-6. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) meet LEED EQ Prerequisite : Minimum Indoor Air Quality Performance Moisture Control HPSB IV.3 UFC para Establish and implement a moisture control strategy for controlling moisture flows and condensation to prevent building damage, minimize mold contamination, and reduce health risks related to moisture. Meet the requirements of ASHRAE 89. Section (Moisture Control) and UFC Chapter 3, Building Envelope Requirements. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) meet None Daylighting HPSB IV.4 UFC para Meet the requirements of ASHRAE 89. Section 8.4. (Daylighting by Sidelighting) or Section 8.5. (Daylighting Simulation). Provide automated lighting controls in accordance with UFC Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED EQ Credit 8.: Daylight and Views - Daylight LEED EQ Credit 6.: Controllability of Systems - Lighting LEED Credit(s) meet None Low Emitting Materials HPSB IV.5 UFC para Specify materials and products with low pollutant emissions, including composite wood products, adhesives, sealants, interior paints and finishes, carpet systems, and furnishings. Meeting the requirements of ASHRAE 89. Sections (Prescriptive Option: Materials) or Section (Performance Option: Materials) demonstrates compliance. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED EQ Credits : Low-Emitting Materials - Adhesives and Sealants (4.), Paints and Coatings (4.2), Flooring Systems (4.3), and Composite Wood and Agrifiber Products (4.4) LEED Credit(s) meet None Protect Indoor Air Quality during Construction HPSB IV.6 UFC para Follow the recommended approach of SMACNA 008. After construction and prior to occupancy, conduct a minimum 72-hour flush-out with maximum outdoor air consistent with achieving relative humidity no greater than 60%. After occupancy, continue flush-out as necessary to minimize exposure to contaminants from new building materials. Meet the requirements of ASHRAE 89. Section (Indoor Air Quality (IAQ) Construction Management). Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED EQ Credit 3.: Construction Indoor Air Quality Management Plan - During Occupancy LEED EQ Credit 3.2: Construction Indoor Air Quality Management Plan - Before Occupancy LEED Credit(s) meet None Environmental Tobacco Smoke Control HPSB IV.7 UFC para Prohibit smoking within the building and within 25 feet (7.62 meters) of all building entrances, operable windows, and building ventilation intakes. Requirement Source Document(s): Federal Register: December 22, 2008 (Volume 73, Number 246) - EO 3058 LEED Credit(s) meet LEED EQ Prerequisite 2: Environmental Tobacco Smoke (ETS) Control 9

10 High Performance Sustainable Building Requirements, UFC , and LEED 2009 References HPSB V: Reduce Environmental Impact of Materials (UFC , 2-7) Recycled Content HPSB V. UFC para Meet the requirements of ASHRAE 89. Section (Recycled Content) when products are available. Per RCRA Section 6002, for EPA-designated products, specify products meeting or exceeding EPA's recycled content recommendations. For other products, specify materials with recycled content when practicable. EPA s recycled content product designations and recycled content recommendations are available on EPA s Comprehensive Procurement Guideline web site at Requirements will be met when products are available. Requirement Source Document(s): RCRA 2002, Sec 6002 LEED Credit(s) aligns closely with LEED MR Credit : Recycled Content - 0% of Content (4.), 20% of Content (4.2) LEED Credit(s) meet None Biologically-based Products HPSB V.2 UFC para Requirement Source Document(s): FSRIA 2002 Section 9002 Per Section 9002 of the Farm Security and Rural Investment Act, specify products composed of the highest percentage of biobased content consistent with the USDA BioPreferred Program, if products meet performance requirements and are available at a reasonable cost. USDA s biobased product designations and biobased content recommendations are available on USDA s BioPreferred web site at LEED Credit(s) aligns closely with LEED MR Credit 6: Rapidly Renewable Materials LEED MR Credit 7: Certified Wood LEED Credit(s) meet None Environmentally Preferable Products HPSB V.3 UFC para 2-7. Use products that have a lesser or reduced effect on human health and the environment. Consider product life-cycle when compared with competing products or services serving the same purpose. A number of standard and eco-labels are available in the marketplace to assist specifiers in making environmentally preferable decisions. Electronic devices, products and appliances purchased should be EPEAT certified. For a list of products and recommendations designated for Federal procurement, consult the Green Products Compilation at and the Federal Green Construction Guide for Specifiers. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) meet None Waste and Materials Management - Recycling HPSB V.4 UFC para Meet the requirements of ASHRAE 89. Section (Storage and Collection of Recyclables Recyclables), where markets or onsite recycling opportunities exist or are anticipated. Incorporate adequate space, equipment, and transport accommodations for recycling in the building design. During a project's planning stage, identify local recycling and salvage operations that could process site-related construction and demolition materials. Provide salvage, reuse and recycling services for waste generated from major renovations, where markets or onsite recycling opportunities exist. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) meet LEED MR Prerequisite : Storage and Collection of Recyclables Waste and Materials Management, Divert 50% from Disposal HPSB V.5 UFC para Meet the requirements of ASHRAE 89. Section (Construction Waste Management-Diversion), where markets or onsite recycling opportunities exist or are anticipated. During a project's planning stage, identify local recycling and salvage operations that could process site-related construction and demolition materials. Provide salvage, reuse and recycling services for waste generated from major renovations, where markets or onsite recycling opportunities exist. During construction, recycle or salvage at least 50 percent of the non-hazardous construction, demolition and land clearing materials, excluding soil, where markets or onsite recycling opportunities exist. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) meet LEED MR Credit 2.: Construction Waste Management Ozone Depleting Substances HPSB V.6 UFC para Meet the requirements of ASHRAE 89. Section (Refrigerants). Exceptions: Refer to UFC for fire system requirements. Requirement Source Document(s): Executive Order 3423 and 354 LEED Credit(s) aligns closely with LEED EA Credit 4: Enhanced Refrigerant Management LEED Credit(s) meet LEED EA Prerequisite 3: Fundamental Refrigerant Management 0

11 AF MILCON Sustainable Building Requirements Legend LEED Credits and/or Prerequisites that align closely with Federal High Performance Sustainable Buildings (HPSB) Requirements These credits and/or prerequisites align closely with the associated HPSB Guiding Principle. Green text They could be either more or less stringent or have different measurement metrics. In the case where one is more stringent than the other, achieving the more stringent one does not imply the less stringent is achieved. LEED Credits and/or Prerequisites that meet Federal High Performance Sustainable Buildings (HPSB) Requirements Blue Text These credits and/or prerequisites have the same requirements as the associated HPSB Guiding Principle. This does not guarantee achieving the LEED Credit, as some documentation methods may vary. Gray Text Light Gray Cell Light Green Cell (When used, conditional formatting changes cell to Green, Yellow, or Red depending on entry) Dark Blue Cell, White Text Light Yellow Cell Recommended (Federal Requirement not fully defined at this time) Cell is populated by other cells. User is not required to enter values. Cell provides a drop-down box for the user to select which LEED Credits and HPSB Requirements that the project is attempting. When a "Yes", "Maybe", or "No" is selected the cell follows the stoplight convention to visually represent progress. The stoplight convention is also used for "Yes", "Maybe" or "No" totals. Some light green boxes also have an option for "N/A" when used for subquestions Cell uses a drop down box and user is designating "Yes" or "N/A" when applicable Cell uses a drop down box and user is designating "Maybe" Cell uses a drop down box and user is designating "No" LEED Credits that meet USAF Energy & Water Criteria (may depend on technologies & strategies). The DoD Sustainable Buildings Policy and AF Sustainable Design and Development Memorandum require a minimum of 20 energy and water credits for all projects seeking LEED certification. SS Credits , WE Credits. - 3, EA Credits -3 and Credits 5-6, IEQ Credit and Credit 8. are always energy and water projects according to AF policy. SS Credit 8 is an energy and water credit if the project uses Option for Indoor Lighting. Innovation and Design and Regional Priority Credits must be specified as energy and water projects for inclusion. Cell is for custom entry on how the project is pursuing LEED Credits and HPSB requirements. These are subquestions and also general information questions. Boxes that appear when cell is selected give further instruction on entering data. Some cells restrict values that can be entered - which is explained if incorrectly entered

12 Federal Requirements for High Performance and Sustainable Buildings (HPSB) & UFC Instructions: Provide a common or project specific justification for an element to be non-applicable, when completed, the Scoresheet tab will allow an N/A response. Justification for Non-Applicable Answers Common Justification Project Specific Justification Complete? HPSB I: Employ Integrated Design Principles (UFC , 2-2) HPSB I. Integrated Design Applicable HPSB I.2 Commissioning Applicable UFC , 2-3. Promote Sustainable Location and Site Development UFC 2-3. Site selection Applicable UFC Mitigation of Heat Island Effect Applicable UFC Reduction of Light Pollution Applicable HPSB III.3-4 Stormwater Management Applicable HPSB II: Optimize Energy Performance (UFC , 2-4) HPSB II. Energy Efficiency Applicable HPSB II.2 On-site Renewable Energy - Solar Hot Water Heater System Applicable HPSB II.3 On-site Renewable Energy Applicable HPSB II.4 Measurement and Verification Water Metering: Select N/A if no service Applicable Electric Metering: Select N/A if no service Applicable Natural Gas Metering: Select N/A if no service Applicable Steam Metering: Select N/A if no service NA Facility does not support this service or feature Yes HPSB III: Protect and Conserve Water (UFC , 2-5) HPSB III. Indoor Water Applicable HPSB III.2 Outdoor Water Applicable HPSB III.4 Water used for heating and cooling Applicable HPSB IV: Enhance Indoor Environmental Quality (UFC , 2-6) HPSB IV. Thermal Comfort Applicable HPSB IV.2 Ventilation Applicable HPSB IV.3 Moisture Control Applicable HPSB IV.4 Daylighting Applicable HPSB IV.5 Low Emitting Materials Applicable HPSB IV.6 Protect Indoor Air Quality during Construction Applicable HPSB V: Reduce Environmental Impact of Materials (UFC , 2-7) HPSB V. Recycled Content Applicable HPSB V.2 Biologically based products Applicable HPSB V.3 Environmentally Preferable Products Applicable HPSB V.4 Waste and Materials Management - Recycling Applicable HPSB V.5 Waste and Materials Management - Divert 50% from Disposal Applicable HPSB V.6 Ozone Depleting Substances Applicable