Multi. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Size: px
Start display at page:

Download "Multi. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration"

Transcription

1 Multi All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration

2 ABOUT DAIKIN Daikin has a worldwide reputation based on 85 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin quality Daikin s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability. Daikin Europe N.V. environmental awareness Air conditioning enhances the indoor climate, providing pleasant working and living conditions in even the harshest climates. In recent years however, aware of the need to safeguard the environment, Daikin has taken great strides to limit negative effects associated with its production and operation. As a result, new energy saving equipment combined with innovative manufacturing techniques, minimise any impact on the environment. Commitment to the environment Concern for the environment is inherent throughout Daikin s global operations, from design and production to the everyday actions of its workforce. Daikin heat pumps in combination with in-house inverter technology offer unparallelled indoor heating comfort and process efficiency. Heat Pump Efficiency Heat pumps can extract heat energy from the outside air, even on the coldest days of winter. Daikin systems are capable of providing comfortable and efficient indoor heating as well as meeting exact industrial heating and cooling requirements. Energy efficient equipment compressor output to match precise system load requirements. Also, when linked with Daikin DC compressor motors, it allows Daikin equipment to achieve the highest COP ratings in the market. Similarly, advanced computerised control packages ensure optimum system efficiency at all times and allow remote monitoring via the internet. Reducing waste Daikin was the first European air conditioning manufacturer to gain ISO14001 environmental certification and all Daikin plants and subsidiaries are now similarly certified. The company s zero waste policy ensures that many of its manufacturing by products can be recycled, reused or recovered. Recycling materials Daikin recycles materials as a matter of course. For instance, the sludge recovered from pre treated waste water is used in cement manufacture. The recycling of other types of waste is also supported by investment in returnable packaging. Many product innovations stem from Daikin environmental awareness. Inverter control reduces unit start up time and varies 2

3 TABLE OF CONTENTS PART 1 - INTRODUCTION Combining highest efficiency and year-round comfort with a heat pump system 4 Inverter technology 4 The benefits of a Multi system 5 Multi possibilities 5 PART 2 - URURU MULTI Multi system 6 Technology 6 1. Ururu humidification 6 2. Ventilation: fresh air, even with closed windows 7 Specifications outdoor units 7 Specifications indoor units 8 Combination tables 10 Accessories outdoor units 11 Accessories indoor units 11 Control systems indoor units 11 PART 3 - MULTI AND SUPER MULTI PLUS Multi outdoor units up to 5 rooms Multi system Specifications outdoor units 13 Super Multi Plus: multi outdoor units up to 9 rooms 1. Super Multi Plus system Technology Specifications outdoor units Selection procedure 16 Indoor outdoor combination table 18 Specifications indoor units 20 Combination tables Multi outdoor units up to 5 rooms Super Multi Plus: Multi outdoor units up to 9 rooms 50 Accessories outdoor units Up to 5 rooms Super Multi Plus: up to 9 rooms 52 Accessories indoor units 53 Up to 5 and 9 rooms 53 Control systems indoor units 54 Up to 5 and 9 rooms 54 Measuring conditions 57 3

4 PART 1 - introduction Combining highest efficiency and year-round comfort with a heat pump system 3/4 kw ambient temperature + 1/4 kw electricity Did you know that... 4/4 kw energy Air to air heat pumps use 3/4th of energy from renewable sources: the ambient air. This energy source is renewable and inexhaustible*. Of course, heat pumps also use 1/4th of electricity to run the system, but increasingly this electricity can also be generated from renewable energy sources (solar energy, wind energy, hydropower, biomass). A heat pump s efficiency is measured in COP (Coefficient Of Performance) for heating and EER (Energy Efficiency Ratio) for cooling. * EU objective COM (2008)/30 Inverter technology The inverter technology, developed by Daikin is a true innovation in the area of climate control. The principle is simple: inverters adjust the power used to suit the actual requirement. No more, no less. This technology provides you with two concrete benefits: Comfort The inverter repays its investment many times over by improving comfort. An air conditioning system with an inverter continuously adjusts its cooling and heating output to suit the temperature in the room. The inverter shortens system start-up time enabling the required room temperature to be reached more quickly. As soon as that temperature is reached, the inverter ensures that it is constantly maintained. Energy efficient Because an inverter monitors and adjusts ambient temperature whenever needed, energy consumption drops by 30% compared to a traditional on/off system! (non inverter) Heating operation: Temperature / Power input Slow start Set temp. Temperature remains stable Air conditioning without Inverter Air conditioning with Inverter Time 4 PART 1 - INTRODUCTION

5 The Benefits of a Multi system Air conditioning in every room A Multi system allows up to 9 indoor units to operate from a single outdoor unit, thereby reducing installation space and costs. All indoor units can be individually controlled and do not need to be installed at the same time - extra units (up to a maximum of 9) can be added later. The widest choice Different types of indoor units wall mounted, concealed ceiling, floor standing etc - in different capacities can be mixed together in Multi system applications. Thus the ideal indoor unit can be selected for the bedroom, living room, office or wherever, according to the installation surface or personal requirements. An ideal indoor climate A single outdoor unit can heat up or cool down a complete house, office or small shop at different times. A pleasant climate can be enjoyed whilst working at the desk in the afternoon, as well as a constant temperature in the living room and cool bedrooms in the evening. Ururu humidification function (2MXU-G) For the humidification, called Ururu in Japanese, moisture is absorbed from the outdoor air. Subsequently, this humidified outdoor air streams into the indoor unit and is evenly distributed throughout the indoor areas. The Ururu Multi, therefore, works without a water reservoir and serves to evenly distribute humidified air. Multi Possibilities Ururu multi, multi up to 5 rooms or up to 9 rooms, the choice is yours! URURU MULTI MULTI SUPER MULTI PLUS HUMIDIFICATION - - FRESH AIR - - HEATING & COOLING MAX. N OF INDOOR UNITS MAX. PIPING LENGTH OPERATION RANGE IN HEATING -15 C~15.5 C -15 C~15.5 C -15 C~20 C SEE PAGE

6 PART 2 - Ururu multi Multi System The Daikin Ururu Multi heat pump system is unique in its ability to supply comfort heating, cooling humidification and fresh air ventilation. Designed primarily for two room residential use, the system comprises a visually attractive wall mounted indoor unit and a robust outdoor unit that can be installed on a balcony or against a wall. Technology 1. Ururu Humidification Humidifying rotor Humidifying heater For the humidification, called Ururu in Japanese, moisture is absorbed from the outdoor air. Subsequently, this humidified outdoor air streams into the indoor unit and is evenly distributed throughout the indoor areas. The Ururu Multi, therefore, works without a water reservoirs and serves to evenly distribute humidified air. Humid heat operation however, is only available during the heat function and switchable from one room to the other. Humidifying unit Humidifying hose Note: This illustration is for pair type. Possition of the humidifying hose is different from that of multi-system. 6 PART 2 - URURU MULTI

7 > > URURU humidification: Maintains a comfortable humidity level without any separate water supply > > Fresh air supply for healthy living > > Up to 2 indoor units can be connected to 1 Multi outdoor unit. All indoor units are individually controllable with remote control and do not need to be installed in the same room or at the same time. 2. Ventilation: fresh air, even with closed windows Unlike the conventional multi system, the Ururu Multi brings fresh, clean and conditioned air into the room. Furthermore, the temperature of the incoming air is brought to the desired level without cold or heat loss. Another benefit is that the air supply fan is accommodated in the outdoor unit, which means that you will never be bothered by any fan noises. Indoor Unit Humidifying rotor + Thermal catalyst > > Elimination of exhaust gases (NOx/SOx) > > Decomposition of bad smells > > Air supply filter: Filters out pollens and dust > > Photocatalytic air purifying filter: Decomposes odours which can not be filtered out > > Flash: formaldehyde, virus, mold fungus > > Temperature control and air intake INDOOR Fresh & clean air OUTDOOR Fresh air Specifications Outdoor units Heating & Cooling 2MXU40G 2MXU50G Dimensions HxWxD mm 675x765x285 Weight kg Casing colour Ivory White Operation range cooling min~max CDB 10~46 heating min~max CWB -15~15.5 Sound pressure level cooling H dba heating H dba Sound power level cooling dba Compressor Hermetically sealed swing compressor Refrigerant type R-410A Additional refrigerant charge kg/m 0.02 (20m or more) liquid mm ø 6.35 Piping connections gas mm ø 9.52 ø 12.7 drain mm ø 18 Maximum piping lenght for total of each room m 30 for one room m 15 Maximum level difference between indoor and outdoor m 15 between indoor units m 7.5 Power supply 1~, V, 50Hz 7

8 CTXU-G Wall Mounted Unit CTXU25-50G ARC452A5 Comfort URURU humidification: maintains a comfortable humidity level without any separate water supply Fresh air intake for healthy living Comfort mode reassures draught free operation Extremely quiet in operation 2 area intelligent eye: air flow is sent to the area in a room where no person is detected 3D air flow: guarantees draught free operation Filter Titanium apatite photocatalytic air purification filter powerfully absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses. Energy efficient ECONO mode decreases the power consumption so that other appliances that need large power consumption can be used. 8 PART 2 - URURU MULTI

9 Specifications Heating & Cooling CTXU25G CTXU35G CTXU42G CTXU50G Dimensions HxWxD mm 295x800x215 Weight kg 9 10 Casing colour White Air flow rate cooling H/M/L/SL m 3 /min 9.1 / 7.1 / 5.2 / / 7.7 / 4.8 / / 7.7 / 6.3 / / 8.6 / 7.0 / 6.0 heating H/M/L/SL m 3 /min 9.8 / 7.9 / 6.2 / / 8.5 / 6.4 / / 9.4 / 7.7 / / 9.3 / 7.6 / 6.7 Fan speed steps 5 steps, silent and auto Sound pressure level cooling H/M/L/SL dba 38 / 32 / 25 / / 34 / 26 / / 38 / 33 / / 39 / 34 / 31 heating H/M/L/SL dba 39 / 34 / 28 / / 36 / 29 / / 38 / 33 / / 39 / 34 / 31 Sound power level cooling dba heating dba Power supply V1 1~/ V/50Hz Infrared remote control ARC452A5 9

10 Combination tables Cooling OUTDOOR UNIT 2MXU40GV1B INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. EER ENERGY LABEL AEC (kwh) A A A A 495 Heating OUTDOOR UNIT 2MXU40GV1B INDOOR UNIT Note: Connected to 2.5,3.5 class of wall mounted unit CTXU-G HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max C D A A COP ENERGY LABEL Cooling OUTDOOR UNIT 2MXU50G2V1B INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. EER ENERGY LABEL AEC (kwh) A A B E A A A A A A A A 635 Heating OUTDOOR UNIT 2MXU50G2V1B INDOOR UNIT Note: Connected to 2.5,3.5,4.2,5.0 class of wall mounted unit CTXU-G HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max A C D D A A A A A A A A COP ENERGY LABEL 10 PART 2 - URURU MULTI

11 Accessories Outdoor units 2MXU-G Humidity hose (Length 10m) KPMH996A10S Humidity hose (Length 15m) KPMH996A15S Drain plug (1) KKP937A4 (1) drain plug kit is included with the unit Accessories Indoor units CTXU-G Titanium apatite photocatalytic air purification filter without frame (1) KAF970A47 Anti-theft protection for remote control KKF910A4 (1) standard accessory Control Systems Indoor units CTXU-G Wiring adapter for time clock / remote control (1) normal open contact normal open pulse contact KRP413AA1S KRP413AA1S Centralised control board up to 5 rooms (2) KRC72A Central remote control Unified ON / OFF control Schedule timer Interface adapter (3) DCS302CA51 DCS301BA51 DCT301BA51 KRP928BA2S (1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply. (2) Wiring adapter is also required for each indoor unit (3) For DIII-NET adapter 11

12 PART 3 - MULTI AND SUPER MULTI PLUS Multi outdoor units up to 5 rooms 1. Multi system Multi inverter controlled outdoor units can operate with 2, 3, 4 or even 5 indoor units. 14 PART 3 - MULTI AND SUPER MULTI PLUS

13 2. Specifications Outdoor units Heating & Cooling 2MXS40G 2MXS50G 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E Dimensions HxWxD mm 550x765x x936x x900x320 Weight kg Casing colour Ivory white Operation range cooling min~max CDB 10~46 heating min~max CWB -15~15.5 Sound pressure level cooling H / M / L dba 47 / - / / - / 44 - / 46 / - - / 48 / - - / 52 / - heating H / M / L dba 48 / - / 44 50/ - / 46 - / 47 / - - / 49 / - - / 52 / - Sound power level cooling M dba Compressor Hermetically sealed swing type Refrigerant type R-410A Additional refrigerant charge kg/m 0.02 (20m or more) 0.02 (30m or more) liquid mm 2x ø6.35 3x ø6.35 4x ø6.35 5x ø6.35 Piping connections gas mm 2x ø9.52 ø x ø ø x ø12.7 2x ø9.52-2x ø12.7 ø x ø15.9 ø2x9.52-1x ø12.7-2x ø15.9 drain mm Maximum piping lenght for total of each room m for one room m Maximum level difference between indoor and outdoor m 15 between indoor units m 7.5 Power supply 1~ / V / 50Hz 15

14 Super Multi Plus: Multi outdoor units up to 9 rooms 1. Super Multi Plus system 2. Technology Smooth air inlet bell mouth & Aero spiral fan These new features assist in significantly reducing noise. Guides are added to the bell mouth intake to reduce turbulence in the air flow generated by fan suction. The new aero spiral fan features fan blades with bent blade edges, further reducing turbulence. DC fan motor The use of a DC fan motor offers substantial improvements in operating efficiency compared to conventional AC motors, especially during low speed rotation. Super aero grille The spiral shaped ribs are aligned with the direction of discharge flow in order to minimise turbulence and reduce noise. Reluctance DC scroll compressor The reluctance brushless DC motor provides significant increases in efficiency compared to conventional AC inverter motors, simultaneously using two different forms of torque (normal and reluctance torque) to produce extra power from small electric currents. The motor comprises powerful neodymium magnets that create the reluctance torque. These magnets are approximately 12 times stronger than ferrite types and make a major contribution to its energy saving characteristics. New aero spiral fan blade tips Escaping edges are sucked in by the bent blade edges, reducing overall turbulence. Efficiency (%) DC motor efficiency (comparison with a conventional AC motor) 60 AC motor 40 Approx. 40% increase Motor speed (rpm) 0 Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory. Low pressure side High pressure side DC motor Approx. 20% increase Suction Scroll Discharge Reluctance DC motor Conventional Iron Neodymium magnet DC fan motor structure N S S N N S S N magnet N S New Rotating stator field Normal torque Reluctance torque 16 PART 3 - MULTI AND SUPER MULTI PLUS

15 SC heat exchanger Optimization of the layout path of the heat exchanger reduces refrigerant flow sound. Smooth sine wave DC inverter Optimizing the sine wave curve results in smoother motor rotation and improved motor efficiency. Night quiet mode (max. -9 dba) During the night the sound level of the outdoor unit can be reduced for a certain period: starting time and ending time can be input 2 modes *1 with low operating sound level at night: Mode 1 Automatic mode Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active 8 hours *2 after the peak temperature in the daytime and operation will return to normal after 9 hours *3. Mode 2 Customized mode Starting and ending times can be input. (External control adapter for outdoor unit, DTA104A61 or DTA104A62 and a separately ordered timer are necessary.) Notes: *1. Determine which mode to select depending on the climatic characteristics of each country. *2. Initial setting. Can be selected from 6, 8 and 10 hours. *3. Initial setting. Can be selected from 8, 9 and 10 hours. 3. Specifications Outdoor units Heating & Cooling RMXS112EV RMXS140EV RMXS160EV Maximum number of connectable indoor units (BP to be connected) Total capacity index of i / u to be connected (max. / min.) 50 / / / 182 Dimensions HxWxD mm 1,345x900x320 Weight kg 120 Casing colour Daikin white Operation range cooling CDB -5 ~ 46 heating CWB -15 ~ 20 Sound pressure level cooling M dba heating M dba Sound pressure night quiet dba Level 1: 47 Level 2: 44 Level 3: 41 Sound power level M dba Compressor type Hermetically sealed scroll type Refrigerant type R-410A liquid mm 9.52 Piping connections gas mm 19.1 drain mm 26x3 system total m Piping length total OU - BP m 55 BP - IU m room BP - IU m 15 OU - BP m 30 Maximum level difference OU - IU m 30 BP - BP / IU - IU m 15 Power supply 1N~ / V/50Hz OU = Outdoor Unit, BP = Branch Provider, IU = Indoor Unit (1): Specifications are with Indoor unit & BP-unit included. EER/COP values are based on 100% connection ratio with wall mounted units. RMXS112 : FTXS50 + FTXS60; RMXS140: 2xFTXS71; RMXS160:2xFTXS50 + FTXS60. The specifications are based on eurovent 2005 tolerances (CAP: > 95%; EER/COP: >92%). (2): The local piping length between 1st branch and indoor unit should be less than 40m. BRANCH PROVIDER BPMKS967B2 BPMKS967B3 Connectable indoor units units 1~2 1~3 Max. indoor unit connectable capacity Max. connectable combination Dimensions HxWxD mm 180x294x350 Weight kg

16 4. Selection procedure (nominal cooling capacity) STEP 1: Select the indoor sizes to match the cooling load of each room. STEP 2: Add the indoor capacity of each indoor unit to calculate the total capacity of the indoor units. Note: -- Maximum 9 indoor units per system -- The total indoor capacity should be between 50% and 130% of the outdoor capacity Indoor class System capacity (kw) STEP 3: Select an outdoor model to match the above mentioned required capacity. STEP 4: Recalculate the capacity of each indoor unit (look up the corrected values in the graph). Capacity of indoor unit = Total system capacity X nominal capacity of indoor total capacity of indoor units Example: Room 1 Room 2 Room 3 Room 4 REQUIRED COOLING CAPACITY 2.2 kw 3 kw 4.3 kw 5.2 kw STEP 1: Selection of indoor units STEP 2: Calculate the total capacity of the indoor units REQUIRED COOLING CAPACITY INDOOR UNIT NOMINAL CAPACITY Room kw FTXS kw Room 2 3 kw FTXG kw Room kw FVXS kw Room kw FBQ kw TOTAL REQUIRED CAPACITY 17.0 kw STEP 3: Selection of the outdoor unit RMXS140EV: maximum total indoor capacity 18.2 kw -> 17 kw is ok RMXS140EV: RMXS140EV - Cooling Capacity RMXS140EV - Heating Capacity RMXS140EV - Cooling Power Input RMXS140EV - Heating Power Input 18,00 16,00 15,00 14,00 System Capacity (kw) 12,00 10,00 8,00 6,00 4,00 2,00 0,00 0,00 2,00 4,00 6,00 8,00 10,00 12,00 14,00 16,00 18,00 18,2 20,00 Total indoor Unit Capacity (kw) 18 PART 3 - MULTI AND SUPER MULTI PLUS

17 STEP 4: Recalculate the capacity of each indoor unit FTXS25 = 15 X 2.5 = 2.2 kw 17 Please contact your local dealer for a complete selection, taking into account your required temperature in heating and cooling mode, pipe losses and the selection of branch boxes (BP units) and pipes. RMXS112EV: RMXS112EV - Cooling Capacity RMXS112EV - Heating Capacity RMXS112EV - Cooling Power Input RMXS112EV - Heating Power Input 16,00 14,00 12,00 System Capacity (kw) 10,00 8,00 6,00 4,00 2,00 0,00 0,00 2,00 4,00 6,00 8,00 10,00 12,00 14,00 16,00 Total indoor Unit Capacity (kw) RMXS160EV: RMXS160EV - Cooling Capacity RMXS160EV - Heating Capacity RMXS160EV - Cooling Power Input RMXS160EV - Heating Power Input 20,00 18,00 16,00 System Capacity (kw) 14,00 12,00 10,00 8,00 6,00 4,00 2,00 0,00 0,00 5,00 10,00 15,00 20,00 25,00 Total indoor Unit Capacity (kw) 19

18 Indoor - Outdoor combination table HEATING AND COOLING Possible Combinations 2MXS40G 2MXS50G 3MXS52E 3MXS68G 4MXS68F 4MXS80E 5MXS90E RMXS112EV RMXS140EV RMXS160EV Wall mounted Concealed ceiling Max n of indoor units FTXG-25JS/W FTXG-35JS/W CTXG-50JS/W FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G FDXS25E7 FDXS35E7 FDXS50C7 FDXS60C7 FDBQ25B FBQ35C FBQ50C FBQ60C FVXS25F Floor standing FVXS35F FVXS50F FLXS25B Flexi type FLXS35B FLXS50B FLXS60B Cassette FCQ35C8* FCQ50C8* FCQ60C8* FFQ25BV FFQ35BV FFQ50BV FFQ60BV FHQ35B Ceiling suspended FHQ50B FHQ60B * In combination with RMXS-EV & Multi, the auto cleaning panel cannot be connected 20 PART 3 - MULTI AND SUPER MULTI PLUS

19 21

20 FTXG-J/CTXG-J Wall Mounted Unit emura FTXG25,35J-W CTXG50J-W FTXG25,35J-S CTXG50J-W ARC466A1 Comfort & Efficiency Remarkable blend of iconic design and engineering excellence with an elegant finish in brushed aluminium or matt crystal white Weekly timer can be set to start heating or cooling anytime on a daily or weekly basis Comfort mode guarantees draught free operation by preventing that warm or cold air is directly blown on to the body Indoor unit silent operation: silent buttons on the remote control lower the operating sound of the indoor unit by 3dBA Movement sensor saves power consumption in unoccupied rooms: when the room is empty, the unit switches to economy mode after 20 minutes and restarts when a person enters the room Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode Filter Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air 22

21 Specifications FTXG-J/CTXG-J Dimensions HxWxD mm 295x915x155 Weight unit kg 11 Casing material Matt crystal white or Brushed aluminium Air flow rate cooling H / M/L / SL m 3 / min 8.8 / 6.8 / 4.7/ /7.3/4.6/ /8.7/6.9/5.9 heating H / M/L / SL m 3 / min 9.6/7.9/6.2// /8.6/6.4/ /9.8/8.1/7.1 Sound pressure level cooling H / M/L / SL dba 38 / 32/25/22 42/34/26/23 47/41/35/32 heating H / M/L / SL dba 39/34/28/25 42/36/29/26 47/41/35/32 Sound power level cooling H dba heating H dba Refrigerant type R-410A Power supply 1~, V, 50Hz Infrared remote control ARC466A41 Note: Sound pressure level measured at a certain distance from the unit Daikin Europe N.V. is proud to announce that Daikin Emura has been awarded an if Product Design Award for For 56 years, the if product design award has served as an internationally recognized trademark for outstanding design. Daikin Emura was evaluated on a range of criteria including design quality, workmanship, choice of materials, degree of innovation, environmental friendliness, functionality, ergonomics and safety. 23

22 FTXS-G Wall Mounted Unit FTXS20-50G ARC452A3 Comfort & Efficiency 2 area intelligent eye: air flow is sent to the area in a room where no person is detected Energy saving during standby mode: reduction of energy from 10W to 2W Weekly timer: allows to program the unit on a weekly basis ECONO mode decreases power consumption so that other appliances that need large power supply can be used Night set mode saves energy by preventing overcooling or overheating during night time Comfort mode guarantees draught free operation Powerful mode can be selected for rapid cooling or heating Whisper quiet operation: down to 22dBA sound pressure level Indoor unit silent operation: "Silent" buttons on the remote control lower the operation sound of the indoor unit by 3dBA 3D air flow combines vertical and horizontal auto-swing to circulate a stream of warm/cool air right to the corners of even large spaces Filter Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses 24

23 Specifications FTXS-G Dimensions HxWxD mm 295x800x x1,050x250 Weight unit kg Casing colour White Air flow rate cooling H / M / L / SL dba 9.4/7.4/5.5/ /7.1/5.2/ /7.7/4.8/ /7.7/6.3/ /8.6/7.0/ /13.8/ 11.3/ /14.5/11.5/10.5 heating H / M / L / SL dba 9.9/8.2/6.5/ /7.9/6.2/ /8.5/6.4/ /9.4/7.7/ /9.3/7.6/ /14.9/12.6/ /14.2/12.6 Sound pressure level cooling H / M / L / SL dba 38 / 32 / 25 / / 32 / 25 / / 34 / 26 / / 38 / 33 / / 39 / 34 / / 41/36/33 46 /42/ 37/34 heating H / M / L / SL dba 38 / 33 / 28 / / 34 / 28 / / 36 / 29 / / 38 / 33 / / 39 / 34 / / 40/35/32 46 /42/ 37/34 Sound power level cooling H dba heating H dba Refrigerant type R-410A Power supply 1~, V, 50Hz Infrared remote control ARC452A3 Note: Sound pressure level measured at a certain distance from the unit 25

24 FDXS-E7/C Slim Concealed Ceiling Unit FDXS25,35E7 ARC433A8 Comfort & Efficiency Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency and very low sound level Home leave operation saves energy during absence Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid cooling or heating Quiet operation: down to 29dBA sound pressure level Filter Standard suction filter: removes airborne dust particles to ensure a steady supply of clean air Flexible Installation Compact dimensions, can easily be mounted in a ceiling void of only 240mm Air filter Suction Chamber Medium external static pressure facilitates unit use with flexible ducts of varying lengths 26

25 Specifications FDXS-E/C Dimensions HxWxD mm 200x700x x1,100x620 Weight unit kg Casing material Galvanised steel plate Air flow rate cooling H / M / L / SL m 3 / min 8.7 / 8.0 / 7.3 / / 10.0 / / 13.5 / 11.2 heating H / M / L / SL m 3 / min 8.7 / 8.0 / 7.3 / / 10.0 / / 13.5 / 11.2 External static pressure max. Pa 30 - Sound power level Sound pressure level Refrigerant type Power supply Infrared remote control Note: Sound pressure level measured at a certain distance from the unit cooling H dba heating H dba cooling H / M / L / SL dba 35.0 / 33.0 /31.0 / / 35.0 / 33.0 / / 36.0 / 34.0 / 32.0 heating H / M / L / SL dba 35.0 / 33.0 / 31.0 / / 35.0 / 33.0 / / 36.0 / 34.0 / 32.0 R-410A 1~, , 50Hz ARC433A8 27

26 FDBQ-B 25 Small Concealed Ceiling Unit FDBQ-B BRC1E51A Comfort & Efficiency Designed for hotel bedrooms Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency and very low sound level Home leave operation saves energy during absence Whisper quiet operation: down to 28 dba sound pressure level Filter Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Flexible Installation Compact dimensions (230mm high & 652mm deep), can easily be mounted in a ceiling void 28

27 Specifications FDBQ-B 25 Dimensions HxWxD mm 230x652x502 Weight unit kg 17.0 Casing material Galvanised steel plate Air flow rate cooling H / L m 3 /min 6.50 / 5.20 heating H / L m 3 /min 6.95 / 5.20 External static pressure Pa - Sound power level Sound pressure level Refrigerant type Power supply Wired remote control Note: Sound pressure level measured at a certain distance from the unit cooling H / L dba 55.0 / 49.0 heating H / L dba 55.0 / 49.0 cooling H / L dba 35.0 / 28.0 heating H / L dba 35.0 / 29.0 R-410A 1~, V, 50Hz BRC1E51A / BRC1D52 / BRC2C51 / BRC3A61 29

28 FBQ-C Concealed Ceiling Unit With Inverter Driven Fan FBQ35,50C BRC1E51A Comfort & Efficiency Reduction in power consumption thanks to DC inverter fans Improved comfort thanks to 3-step airflow control Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The use of an integrated inverter control ensures maximum comfort and efficiency Home leave operation saves energy during absence Filter Standard air filter: removes airborne dust particles to ensure a steady supply of clean air Flexible Installation Maximum external static pressure (ESP) is 100Pa Possibility to change ESP through wired remote control allows optimisation of the supply air volume Easy installation thanks to automatic air flow adjustment towards nominal air flow rate 30

29 Easy installation thanks to automatic air flow adjustment towards nominal air flow: Installation made easier Reduced installation time After installation, it is possible that the actual duct resistance is lower than expected at time of designing. As a consequence the air flow will be too high. With the automatic air flow adjustment function the unit can adapt its fan speed to a lower curve, so the air flow decreases. The air flow will always be within 10% of the rated air flow because of the amount of possible fan curves (more than 8 fan curves available per model). Alternatively the installer can manually select a fan curve with the wired remote control. External static pressure (Pa) Fan characteristic curve Actual duct resistance curve Duct resistance curve at the time of designing Rated air flow Airflow without air flow automatic adjustment Actual airflow Air flow (m³/min) +/- 10% Specifications FBQ-C Dimensions HxWxD mm 300x700x x1,000x700 Weight unit kg Casing material Galvanised steel plate Air flow rate cooling H/L m 3 /min 16 / / / 15 heating H/L m 3 /min 16 / / / 15 External static pressure max. 100 Fan speed steps Sound power level cooling H dba Sound pressure level cooling H/L dba 37 / / / 29 heating H/L dba 37 / / / 29 Refrigerant type R-410A Power supply 1~, V, 50/60Hz Wired remote control BRC1E51A, BRC1D52, BRC2C51, BRC3A61 Infrared remote control BRC4C65 Decoration panel BYBS45D BYBS71D Decoration panel option EKBYSB Note: Sound pressure level measured at a certain distance from the unit 31

30 FVXS-F Floor Standing Unit FVXS-F ARC452A1 Comfort & Efficiency Weekly timer: allows to program the unit on a weekly basis Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid cooling or heating Whisper quiet operation: down to 23 dba sound pressure level Vertical auto-swing function moves the discharge flaps up and down for efficient air distribution throughout the room The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency Home leave operation saves energy during absence Filter Titanium apatite photocatalytic air purification filter absorbs microscopic particles, decomposes odours and even deactivates bacteria and viruses Flexible Installation Ideal for installation beneath a window Can be installed against a wall or recessed 32

31 Specifications FVXS-F Dimensions HxWxD mm 600x700x210 Weight unit kg 14 Casing colour White Air flow rate cooling H / M / L / SL m 3 / min 8.2 / 6.5/4.8 / / 6.7/4.9 / /9.2/ 7.8 / 6.6 heating H / M / L / SL m 3 / min 8.8 /6.9/ 5.0 / /7.3/ 5.2 / /10.1/ 8.5 / 7.1 Sound power level cooling H dba heating H dba Sound pressure level cooling H / M / L / SL dba 38 / 32/26 / / 33/27 / /40/ 36 / 32 heating H / M / L / SL dba 38 /32/ 26 / / 33/27 / /40/ 36 / 32 Refrigerant type R-410A Power supply 1~, V, 50Hz Infrared remote control ARC425A1 Note: Sound pressure level measured at a certain distance from the unit 33

32 FLXS-B Flexi Type Unit FLXS-B ARC433A6 Comfort & Efficiency Can fit on either ceiling or lower wall. Its low height enables it to fit beneath a window Night set mode saves energy by preventing overcooling or overheating during night time Powerful mode can be selected for rapid cooling or heating Whisper quiet operation: down to 28 dba sound pressure level Vertical auto-swing function moves the discharge flaps up and down for efficient air distribution throughout the room The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency Home leave operation saves energy during absence Filter Air purification filter with photocatalytic deodorising function: deodorises the air, powerfully decomposes cigarette and pet odours, removes house dust and pollen, deactivates bacteria and viruses Flexible Installation Allows both ceiling suspended as floor standing installation. 34

33 Specifications FLXS-B Dimensions HxWxD mm 490x1,050x200 Weight unit kg Casing colour colour Almond white Air flow rate cooling H /M/ L / SL m 3 / min 7.6 / 6.8/6.0 / / 7.6/6.6 / / 10.0/8.5 / / 10.7 / 9.3 / 8.3 heating H /M/ L / SL m 3 / min 9.2 / 8.3/7.4 / /8.9/ 8.0 / / 9.8/7.5 / / 10.6 / 8.4 / 7.5 Sound power level cooling H dba Sound pressure level cooling H /M/ L / SL dba 37 / 34/31 / /35/ 32 / / 43/39 / / 45 / 41 / 39 heating H /M/ L / SL dba 37 / 34/31 / / 36/33 / / 41/35 / / 42 / 37 / 34 Refrigerant type R-410A Power supply 1~, V, 50 Hz Infrared remote control ARC433A5 Notes: Sound pressure level measured at a certain distance from the unit 35

34 FCQ-C Round Flow Ceiling Mounted Cassette Standard panel in Pure White with grey louvres Standard panel in Pure White, including white louvres BRC1E51A BRC7F532 Comfort & Efficiency 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel is available in 2 different variations: Standard panel in white (RAL9010) with grey louvers, standard panel in full white (RAL9010) including white louvers The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency and very low sound level Home leave operation saves energy during absence Fresh air intake: up to 20% (optional kit required) Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air flow patterns possible 36

35 Flexible Installation & Easy Maintenance Reduced installation height: 214mm for class Standard connection to D3-net without the need of an adapter PCB Easy condensate drain check Examples of Airflow Patterns 360 radial round flow enables uniform air flow distribution Roundflow 4-Way blow 3-Way blow 2-Way blow Specifications FCQ-C Dimensions HxWxD mm 204x840x840 Weight unit kg 19 Casing material Galvanised steel Air flow rate cooling H / L m 3 /min 10.5 / / / 8.5 heating H / L m 3 /min 12.5 / / / 8.5 Fan speed steps 2 Sound power level cooling H dba Sound pressure cooling H / L dba 31 / / 28 level heating H / L dba 31 / / 28 Refrigerant type R-410A Power supply 1~, V, 50Hz model BYCQ140CW1 1 / BYCQ140CW1W 2 Decoration panel colour Pure white (RAL9010) dimensions (HxWxD) mm 50x950x950 weight kg 5.5 Wired remote control BRC1E51A / BRC1D52 Infrared remote control BRC7F532F Notes: 1 Pure white standard panel with grey louvers 2 Pure white standard panel with white louvers Sound pressure level measured at a certain distance from the unit 37

36 FFQ-BV Way Blow Ceiling Mounted Cassette 600 x 600mm FFQ-BV BRC1E51A BRC7E530W Comfort & Efficiency Modern style decoration panel in pure white (RAL9010) The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency and very low sound level Home leave operation saves energy during absence Whisper quiet operation: down to 24.5 dba sound pressure level Fresh air intake for healthy living Comfortable horizontal air discharge ensures draught free operation and prevents ceiling soiling Flexible Installation & Easy Maintenance Compact casing (575mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles 38

37 Specifications FFQ-BV Dimensions HxWxD mm 286x575x575 Weight kg 17.5 Casing unit Galvanised steel plate Air flow rate cooling H / L m 3 / min 9.0 / / / / 10.0 heating H / L m 3 / min 9.0 / / / / 10.0 Fan speed material 2 steps (direct drive) Sound power level cooling H dba heating H dba Sound pressure level cooling H / L dba 29.5 / / / / 32.0 heating H / L dba 29.5 / / / / 32.0 Refrigerant type R-410A Model BYFQ60B Decoration panel Colour Pure white (RAL9010) Dimensions (HxWxD) mm 55x700x700 Weight kg 2.7 Power supply 1~, 230V, 50Hz Wired remote control BRC1E51A / BRC1D52 Infrared remote control BRC7E530W Note: Sound pressure level measured at a certain distance from the unit 39

38 FHQ-B Ceiling Suspended Unit FHQ-B BRC1E51A BRC7EA63W Comfort & Efficiency Wider air discharge thanks to Coanda effect: up to 100 degrees Coanda effect 100 The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency Home leave operation saves energy during absence Flexible Installation & Easy Maintenance Can be installed in both new and existing buildings. Air flow distribution for ceiling heights up to 3.8m without loss of capacity The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space Lateral service space 40

39 Specifications FHQ-B Dimensions HxWxD mm 195x960x x1,160x680 Weight unit kg Casing colour White Air flow rate cooling H / L m 3 / min 13 / / / 13 heating H / L m 3 / min 13 / / / 13 Sound power level cooling H / L dba 53 / / / 49 Sound pressure level cooling H / L dba 37 / / / 33 heating H / L dba 37 / / / 33 Refrigerant type R-410A Power supply 1~, 230V, 50Hz Wired remote control BRC1E51A / BRC1D52 Infrared remote control BRC7EA63W Note: Sound pressure level measured at a certain distance from the unit 41

40 Combination tables 1. Multi outdoor units up to 5 rooms Cooling OUTDOOR UNIT 2MXS40G2V1B Heating OUTDOOR UNIT 2MXS40G2V1B INDOOR UNIT INDOOR UNIT Note: Connected to 2.0, 2.5, 3.5: wall mounted G type Cooling OUTDOOR UNIT 2MXS50G2V1B Heating OUTDOOR UNIT 2MXS50G2V1B INDOOR UNIT INDOOR UNIT Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0: wall mounted G type cooling CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. cooling CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM Min. Nom. Max. Min. Nom. Max. EER COP EER COP ENERGY LABEL ENERGY LABEL ENERGY LABEL ENERGY LABEL AEC (kwh) A A A A A A A A B C D A A A A A AEC (kwh) A A A D E 1, A A A A A A A A A A A A A A B C D D A A A A A A A A A A A A A 42 PART 3 - MULTI AND SUPER MULTI PLUS

41 Cooling OUTDOOR UNIT 3MXS52E3V1B INDOOR UNIT cooling CAPACITY (kw) Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type TOTAL CAPACITY (kw) POWER INPUT COOLING (W) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. max. EER ENERGY LABEL A A A A C A A A A A A A A A A A A A A A A A A A A A A A A 610 AEC (kwh) Heating OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY POWER INPUT HEATING (W) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. Nom. max. COP ENERGY LABEL 3MXS52E3V1B A B D E E B B B B A B B B A B B A B A A A A A A A A A A A Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type 43

42 Cooling OUTDOOR UNIT INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT COOLING (kw) A ROOM B ROOM C ROOM Min. Nom. Max. Min. Nom. Max. EER ENERGY LABEL AEC (kwh) A A A A C C 1, A A A C 1, C 1, B 1, A C 1, D 1, C 1, B 1, D 1, D 1, C 1, B 1, D 1, C 1, B 1, C 1,155 3MXS68G2V1B A 1, A A A 1, A 1, A 1, A A 1, A 1, A 1, A 1, A A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A A 1, A 1, A A 1, A 1,035 Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type 44 PART 3 - MULTI AND SUPER MULTI PLUS

43 Heating OUTDOOR UNIT INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY (kw) POWER INPUT HEATING (kw) A ROOM B ROOM C ROOM D ROOM Min. Nom. Max. Min. Nom. Max. COP ENERGY LABEL A C D D E D B C D D D B C D D D B D D D B D D B D B A A A A A 4MXS68F2V1B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: Connected to 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 wall mounted G type 45

44 Cooling OUTDOOR UNIT INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY Power input (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max A A C D D B D 1, A A B C 1, D 1, C 1, C 1, A B D 1, D 1, C 1, C 1, D 1, E 1, D 1, D 1, D 1, E 1, E 1, D 1, D 1, D 1, D 1, C 1, B 1, B 1, B 1, A 865 4MXS80E7V3B A 1, C 1, C 1, C 1, B 1, B 1, B 1, C 1, C 1, C 1, B 1, B 1, C 1, C 1, C 1, B 1, B 1, C 1, C 1, B 1, B 1, C 1, A 1, A 1, A 1, C 1, C 1, C 1, C 1, B 1, B 1, D 1, D 1, C 1, B 1, B 1, D 1,435 Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 wall mounted G type EER ENERGY LABEL AEC (kwh) 46 PART 3 - MULTI AND SUPER MULTI PLUS

45 Heating OUTDOOR UNIT 4MXS80E7V3B INDOOR UNIT HEATING CAPACITY (kw) TOTAL HEATING CAPACITY Power input (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 wall mounted G type COP ENERGY LABEL 47

46 Cooling OUTDOOR UNIT 5MXS90E7V3B INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY Power input (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max. Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0,6.0 and 7.1 wall mounted G type EER ENERGY LABEL AEC (kwh) A A B B B B D 1, A A A B C 1, B 1, C 1, A B C 1, D 1, C 1, C 1, D 1, D 1, D 1, C 1, D 1, D 1, D 1, D 1, D 1, D 1, D 1, D 1, C 1, C 1, C 1, A A B 1, B 1, C 1, B 1, B 1, A 1, B 1, C 1, C 1, B 1, C 1, C 1, C 1, C 1, C 1, C 1, D 1, D 1, C 1, C 1, D 1, B 1, B 1, A 1, A 1, B 1, C 1, C 1, C 1, B 1, C 1, C 1, D 1, C 1, C 1, C 1, D 1, D 1, PART 3 - MULTI AND SUPER MULTI PLUS

47 Cooling OUTDOOR UNIT 5MXS90E7V3B INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY Power input (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max. Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type / op 6.0 en 7.1 wall mounted F type EER ENERGY LABEL AEC (kwh) C 1, C 1, D 1, C 1, B 1, A 1, A 1, D 1, D 1, D 1, C 1, C 1, D 1, D 1, C 1, C 1, D 1, C 1, B 1, A 1, D 1, D 1, C 1, C 1, D 1, C 1, C 1, A 1, A 1, A 1, B 1, B 1, A 1, B 1, A 1, B 1, B 1, B 1, A 1, B 1, B 1, C 1, C 1, A 1, A 1, C 1, C 1, A 1, A 1, B 1, A 1, A 1, B 1, B 1, B 1, A 1, A 1, B 1, C 1, C 1, A 1, A 1, C 1, C 1, A 1, B 1, A 1, C 1, C 1, C 1, A 1, C 1, C 1, B 1, C 1,580 49

48 Cooling OUTDOOR UNIT 5MXS90E7V3B INDOOR UNIT cooling CAPACITY (kw) TOTAL CAPACITY Power input (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max. Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0 wall mounted G type / op 6.0 en 7.1 wall mounted F type EER ENERGY LABEL AEC (kwh) C 1, B 1, B 1, C 1, C 1, A 1, A 1, C 1, C 1, C 1, A 1, A 1, C 1, C 1, A 1, B 1, C 1, C 1, C 1, A 1, C 1, C 1, C 1, C 1, C 1, C 1, C 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, B 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, A 1, B 1, B 1, A 1, A 1, B 1, A 1, A 1, A 1, B 1, A 1, A 1, B 1, B 1, A 1, A 1, B 1, A 1, A 1, A 1, B 1, A 1, A 1, B 1, A 1, B 1, A 1, A 1,375 50

49 Heating OUTDOOR UNIT 5MXS90E7V3B INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY Power input HEATING (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max B C D D D D D A A C C B B C B D D B C C D D C C C E D C C D C B A A A A A A B B A A A A B B A A B C C A A C C A A B A A A A A B C C A A C C C A A C C Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 wall mounted G type COP ENERGY LABEL 51

50 Heating OUTDOOR UNIT 5MXS90E7V3B INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY Power input HEATING (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max A A B A A A A C C C A A C B A A B A A A C B A A B A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 wall mounted G type COP ENERGY LABEL 52 PART 3 - MULTI AND SUPER MULTI PLUS

51 Heating OUTDOOR UNIT 5MXS90E7V3B INDOOR UNIT HEATING CAPACITY (kw) TOTAL CAPACITY Power input HEATING (kw) A ROOM B ROOM C ROOM D ROOM E ROOM Min. Nom. Max. Min. nom. Max A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A Note: connected to 2.0, 2.5, 3.5, 4.2, 5.0, 6.0 and 7.1 wall mounted G type COP ENERGY LABEL 53

52 Accessories Outdoor units 1. Up to 5 rooms MXS-E/F/G 40 50~90 Air direction adjustment grille KPW937A4 KPW945A4 Drain plug (1) KKP937A4 KKP937A4 (1) standard accessory 2. Super multi plus: Up to 9 rooms RMXS-EV Drain plug* KKPJ5F180 REFNET Refnet joint KHRQ22M20TA BRANCH PROVIDER Branch provider (2 rooms) Branch provider (3 rooms) BPMKS967B2 BPMKS967B3 *1 drain plug kit is included with the unit *2 To be able to control the BYCQ140CGW1 the wired remote control BRC1E51A is needed. - The BYCQ140CGW1 is not compatible with RMXS-EV and multi. 54 PART 3 - MULTI AND SUPER MULTI PLUS

53 Accessories Indoor units Up to 5 and 9 rooms FTXG-J & CTXG-J Anti-theft protection for remote control KKF910A4 FTXS-G Titanium apatite photocatalytic air purification filter without frame KAF968A42 (1) KAF952B42 (1) Anti-theft protection for remote control KKF910A4 KKF917A4 (1) standard accessory FLXS-B Photocatalytic deodorising filter, with frame KAZ917B41 Photocatalytic deodorising filter, without frame KAZ917B42 Air purification filter, with frame KAF925B41 Air purification filter, without frame KAF925B42 Anti-theft protection for remote control KKF917AA4 FVXS-F Titanium apatite photocatalytic air-purifying filter without frame KAF968A42 (1) Anti-theft protection for remote control KKF936A4 (1) standard accessory FDXS-E7/C Anti-theft protection for remote control KF917AA4 KF917AA4 FBQ-C Decoration panel BYBS45D BYBS71D Decoration panel option EKBYBSD Air discharge adapter for round duct KDAJ25K56A KDAJ25K71A FCQ-C Decoration panel BYCQ140CW1 + BYCQ140CW1W (1) + BYCQ140CGW1 (2) Replacement long-life filter non-woven type KAFP551KA160 Fresh air intake kit (min. 20% fresh air) chamber type KDDQ55C140 Sealing member of air discharge outlet KDBH55C140 (1) The BYCQ140CW1W has white insulations. Be informed that formation of dirt on white insulations is visibly stronger and that it is consequently not advised to install this panel in environments exposed to concentrations of dirt. (2) To be able to control the BYCQ140CGW1 the wired remote control BRC1E51A is needed. The BYCQ140CGW1 is not compatible with RMXS-EV and multi. FFQ-BV Decoration panel BYFQ60B BYFQ60B Long-life filter KAFQ441BA60 KAFQ441BA60 Fresh air intake kit Direct installation type KDDQ44XA60 KDDQ44XA60 Sealing member of air discharge outlet KDBH44BA60 KDBH44BA60 Panel spacer KDBQ44B60 KDBQ44B60 FHQ-BV Replacement long-life filter KAF501DA56 KAF501DA80 Drain-up kit KDU50N60VE L-type piping kit (upward direction) KHFP5M35 KHFP5MA63 55

54 Control Systems Indoor units Up to 5 and 9 rooms FTXG-J & CTXG-J Wiring adapter for time clock / normal open contact KRP413A1S remote control normal open pulse contact KRP413A1S Centralised control board up to 5 rooms (2) KRC72 Central remote control DCS302C51 Unified ON / OFF control DCS301B51 Schedule timer DST301B51 Interface adapter (3) KRP928A2S Wired remote control BRC944B2 (1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply. (2) Wiring adapter is also required for each indoor unit. (3) For DIII-NET adapter FTXS-G Wired remote control BRC944B2 Centralised control board up to 5 rooms KRC72 (2) Central remote control DCS302C51 Unified ON / OFF control DCS301B51 Schedule timer DST301B51 Interface adapter KRP928B2S (3) Wiring adapter for time clock / normal open contact KRP413A1S (1) Remote control normal open pulse contact KRP413A1S (1) (1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply. (2) Wiring adapter is also required for each indoor unit. (3) For DIII-NET adapter FDBQ-B 25 Wired remote control BRC1E51A (1) / BRC1D528 Adapter for wiring (hour meter) (2) EKRP1B2 Remote ON / OFF, forced OFF EKRORO3 (1) Languages included: English, German, French, Dutch, Spanish, Italian, Greek, Portuguese, Russian and Turkish. (2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment. 56 PART 3 - MULTI AND SUPER MULTI PLUS

55 FLXS-B Wiring adapter for time clock / normal open contact KRP413A1S remote control (1) normal open pulse contact KRP413A1S Centralised control board up to 5 rooms (2) KRC72 Central remote control DCS302C51 Unified ON / OFF control DCS301B51 Schedule timer DST301B51 Interface adapter (3) KRP928A2S (1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply. (2) Wiring adapter is also required for each indoor unit. (3) For DIII-NET adapter FVXS-F Centralised control board up to 5 rooms KRC72 Wiring adapter normal open / normal normal open KRP413A1S open pulse contact normal open pulse contact KRP413A1S Interface adapter (1) KRP928B2S Central remote control DCS302C91 Unified ON / OFF control DCS301B51 Schedule timer DST301B51 (1) For DIII-NET adapter FDXS-E7/C Wiring adapter for time clock / normal open contact KRP413A1S KRP413A1S remote control (1) normal open pulse contact KRP413A1S KRP413A1S Centralised control board up to 5 rooms (2) KRC72 KRC72 Central remote control DCS302C51 DCS302C51 Unified ON / OFF control DCS301B51 DCS301B51 Schedule timer DST301B51 DST301B51 Interface adapter (3) KRP928A2S KRP928A2S (1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply. (2) Wiring adapter is also required for each indoor unit. (3) For DIII-NET adapter 57

56 FBQ-C wired BRC1D528 / BRC1E51A (4) Remote control heat pump BRC4C65 infrared cooling only BRC4C66 Centralised remote control DCS302C51 Mounting phase for adapter PCB KRP4A96 Unified ON / OFF control DCS301B51 Schedule timer DST301B51 Wiring adapter interlock for fresh air intake fan (3) KRP1C64 Wiring adapter for external electrical appendices (3) KRP4A51 Interface adapter for Sky Air DTA112BA51 Remote ON / OFF and forced OFF kit EKRORO3 Option PCB for external electrical heater, humidifier and/or hour meter (1) (3) EKRP1B2A (1) Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment (refer to installation manual of EKRP1B2A). (2) If installing an electrical heater, an option PCB for external electrical heater (EKRP1B2) for each indoor unit is required. (3) Mounting plate KRP4A96 is required for these options. Maximum 2 options PCB can be mounted. (4) Included languages: English, German, French, Dutch, Spanish, Italian, Greek, Portuguese, Russian and Turkish FCQ-C heat pump BRC7F532F infrared Remote control cooling only BRC7F533F wired BRC1D528/BRC1E51A(3) Centralised remote control DCS302C51 Unified ON / OFF control DCS301B51 Schedule timer DST301B51 Wiring adapter for electrical appendices (1) (4) KRP1BA57 Wiring adapter for electrical appendices (2) (4) KRP4A53 Wiring adapter (hour meter) EKRP1C11 (1) Installation box for adapter PCB KRP1H98 Remote ON / OFF EKRORO3 Remote sensor KRCS01-4 Electrical box with earth terminal (2 blocks) KJB212AA (1) Installation box is necessary for these adapters. (2) All options are supplied as kit. (3) Included languages: English, German, French, Dutch, Spanish, Italian, Greek, Portuguese, Russian and Turkish. (4) Options not available in combination with bycq140cgw1. FFQ-B Remote control Centralised remote control Unified ON / OFF control Schedule timer Wiring adapter for electrical appendices (1) Wiring adapter for electrical appendices (1) Wiring adapter (hour meter) Remote sensor Installation box for adapter PCB Interface adapter for Sky Air -Series Remote ON / OFF and forced OFF kit infrared heat pump cooling only BRC7E530W BRC7E531W wired BRC1D528/BRC1E51A (3) (1) Installation box for adapter PCB (KRP1B101) is necessary. (2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment. (3) Included languages: English, German, French, Dutch, Spanish, Italian, Greek, Portuguese, Russian and Turkish. DCS302C51 DCS301B51 DST301B51 KRP1B57 KRP4A53 EKRP1B2 KRCS01-1 KRP1BA101 DTA112B51 EKRORO FHQ-B Remote control Centralised remote control Unified ON / OFF control Schedule timer Wiring adapter for wiring Wiring adapter for electrical appendices Wiring adapter for wiring (hour meter) (2) Interface adapter for Sky Air -Series Installation box for adapter PCB Remote ON / OFF, forced OFF infrared heat pump cooling only BRC7E63 BRC7EA66 wired BRC1D528/BRC1E51A (3) (1) Installation box for adapter PCB (KRP1C93) is necesarry (2) Possibility to connect an hour meter (field supply). This part should not be installed inside the equipment (3) Included languages: English, German, French, Dutch, Spanish, Italian, Greek, Portuguese, Russian and Turkish. DCS302C51 DCS301B51 DST301B51 KRP1B54 KRP4A52 EKRP1B2 DTA112B51 KRP1C93 EKRORO 58 PART 3 - MULTI AND SUPER MULTI PLUS

57 Measuring conditions Heating & Cooling 1) nominal cooling capacities measured at: indoor temperature outdoor temperature equivalent piping length: outdoor-bp BP-indoor level difference 27 CDB / 19 CWB 35 CDB 5m 3m 0m 2) nominal heating capacities measured at: indoor temperature outdoor temperature equivalent piping length: outdoor-bp BP-indoor level difference 20 CDB 7 CDB / 6 CWB 5m 3m 0m 3) capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat 4) sound pressure level measured at a certain distance from the unit 59

58

59 NOTES 61

60 Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Multi units are Eurovent certified for combinations up to 2 indoor units. FSC ECPEN The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium BE RPR Oostende ECPEN XXX 01/10 Copyright Daikin The present publication supersedes ECPEN Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende