3 Contents 1 Your new retail scale Most important functions Device overview Safety instructions Calibration instructions..8 2 Setting up Scope of delivery Requirements for scale s location Setting up the scale Inserting the batteries Connecting to mains power Turning scale on/off Cleaning Operation Free input Working with PLUs Using tare Zeroing By-count operation Accumulating Change function Fix unit price and/or tare Hold function Weighing with 100 g (1/2 lb / 1/4 lb) price unit Switching weighing unit between kg and lb Displaying the price to pay in EURO Backlight function Ticket printing Printing reports Operator setup Setup operation Operator setup overview Setting date and time 31 Order number OHAUS Operator Manual Aviator

4 5 What do you do if.?.32 6 Technical data and accessories Technical data Accessories.33 7 Appendix Disposal OHAUS Operator Manual Aviator 7000 Order number

5 1 Your new retail scale 1.1 Most important functions Congratulations on your new scale. This robust digital price computing scale with its hygienic design and battery operation facilitates comfortable mobile selling while maintaining the highest accuracy. POS connectivity provides external printing and/or data transfer with multiple protocols. 1.2 Device overview The scale is available in two versions: as a compact scale or as a tower version Keyboard The keyboard is divided into four sections. The advanced function keys depend on the region. 1 2a 3 4 2b 2c 1 PLU preset keys 2a Advanced function keys, Basic (rest of the world) 2b Advanced function keys, Europe 2c Advanced function keys, 2 variants for North America 3 Numeric keypad 4 Basic function keys Order number OHAUS Operator Manual Aviator

6 Display The display is laid out as follows from the customer and vendor point of view: Your new retail scale Vendor display Customer display Calibration plate 2 Weight display 3 Unit price 4 Price 5 Preset tare 6 Level indicator In addition to the weight and price, the following status messages and indicators can be displayed: ZERO Scale is at center of zero PT Keyboard tare or tare recalled from PLU NET Net value (gross minus tare); push button tare exists FIX Unit price and/or tare is fixed X Scale is in by-count mode 100 g 100 g pricing is activated 1/2 1/2 lb pricing is activated 1/4 1/4 lb pricing is activated Add Scale is in accumulation mode; data exists in the accumulation memory Total The displayed total price is added into the accumulation memory Battery is approx. full 2/3 battery power left 1/3 battery power left Battery power at a critical level 6 OHAUS Operator Manual Aviator 7000 Order number

7 1.2.2 Connections and features on the underside The following connections are located on the underside of the scale: 1 Adjustable feet 2 Tower mounting 3 Grips 4 Power supply connection 5 Power supply storage box 6 Calibration button 7 Interface connection; RS232/USB, depending on cable 8 Battery switch: NiMH D-cell Order number OHAUS Operator Manual Aviator

8 1.3 Safety instructions Your new retail scale Basic safety instructions Read these operating instructions prior to using your scale. Store these operating instructions in the vicinity of the scale for future reference. Do not open the scale. Always unplug the scale before cleaning. Safety instructions for battery operation The battery must not come into contact with chemical solvents, oil or water. Keep batteries away from heat and fire. Do not open the battery. 1.4 Calibration instructions M Scales which have been factory-calibrated have a label indicating this on the packaging. Scales with a green M on the type plate are ready for operation. M Scales which are calibrated in two stages have a label indicating this on the packaging. These scales have only been calibrated in a first stage (declaration of conformity in accordance with EN ). The second stage of the calibration must be done on-site by authorized service personnel. Please contact your local representative. Medium accuracy scales that are used in commerce, where certified calibration is required, must be calibrated and certified. Observe the respective measurement data guidelines in your country. 8 OHAUS Operator Manual Aviator 7000 Order number

9 2 Setting up 2.1 Scope of delivery Check if the delivery is complete: Scale Stainless steel weighing pan Power supply, stored in the power supply storage compartment under the scale Operating instructions Tower with mounting material, tower version only 2.2 Requirements for scale s location The right location is critical to weighing accuracy. Conditions for an ideal location No shocks and vibrations No excessive temperature fluctuations No direct sunlight No strong drafts Select a stable, vibration-free and preferably horizontal location for your scale. 2.3 Setting up the scale Levelling the scale Only a perfectly levelled scale delivers accurate weighing results. The scale is equipped with a level indicator to make it easier to level the scale. To level the scale, turn the scale s adjustable feet until the air bubble in the level indicator is in the inner circle. Order number OHAUS Operator Manual Aviator

10 2.3.2 Mounting the tower With the tower version the customer display is at eye level. The tower must be mounted first. Setting up 1. Remove the weighing pan and turn over the scale. 2. Open the tower base cover. 3. Route the cable from the tower through the tower base. 4. Put the tower on the tower base and fix it with two screws. 5. Clip the cable connectors together. 6. Put the cables and connectors in the tower base. 7. Close the tower base cover. 8. Turn over the scale and put the weighing pan back on. 2.4 Inserting the batteries 1. Make sure that the external power supply is disconnected. 2. Remove the weighing pan. 3. Remove the battery compartment cover. 4. Turn over the scale and set the battery switch as follows: for rechargeable D-cell batteries: "NiMH". for non-rechargeable D-cell batteries: "Battery" 5. Turn over the scale. 10 OHAUS Operator Manual Aviator 7000 Order number

11 WARNING Risk of explosion when the battery switch is not set correctly. Make sure that the battery switch is in the right position for the desired type of battery. 6. Place the batteries in the compartment so that the positive poles face the springs, see pole markings on cover and housing. 7. Close the battery compartment and put the weighing pan back on. 2.5 Connecting to mains power The power supply is stored in a department under the scale to support save transport. 1. Connect the supplied power supply unit to the power connection socket on the underside of the scale. 2. Plug the power supply unit into a correctly grounded power outlet. 2.6 Turning scale on/off To turn the scale on press the On/Off key. To turn the scale off press and hold the On/Off key until a long beep can be heard. After the scale is turned on, it runs through a short display test. All segments and status messages briefly light up, the software version is displayed. The scale is ready when the weight display appears. 2.7 Cleaning CAUTION Damage to the scale Turn off and unplug the device before cleaning. Do not open the device. Make sure that no fluids get inside the device. Do not use scouring powders or plastic dissolving cleaning agents for cleaning. Cleaning Remove the weighing pan and clean it with a commercially available household detergent. If heavily soiled, clean the surface of the device with a damp cloth that has been dipped in water containing a mild liquid detergent and well wrung out. Order number OHAUS Operator Manual Aviator

12 3 Operation Operation 3.1 Free input You can immediately use your scale for weighing and selling without prior configuration. 1. Place the item on the scale Enter the unit price (price/kg). The price to pay is displayed. 3. Remove the item from the scale. All displays return to 0. Enter the unit price as usual without the decimal point, but with all the decimal places. 3.2 Working with PLUs You can save the price and/or tare for frequently sold goods in the scale s PLU memory and simply call it up later. In the factory setting unit price and tare are saved in a PLU Creating a PLU Enter the unit price (price/kg). p 2. Press and hold the PLU key until a long beep can be heard. P appears in the weight display Enter the PLU number (between 1 and 9999). 4. Wait until the scale beeps twice. The PLU is stored and all displays return to OHAUS Operator Manual Aviator 7000 Order number

13 To save the tare weight in the PLU: before entering the unit price, first tare the corresponding container, see section 3.3. The scale can store 100 PLUs. If the memory is full and you want to store a new PLU the messages "Full" and "Delete" are displayed.you can either overwrite a specific PLU or delete the whole PLU memory. To overwrite an existing PLU press the C key and create a new PLU with the number you want to overwrite. To delete the whole PLU memory press the Enter (On/Off) key Calling up PLUs Depending on the setting of operator setup Step 7, there are two ways to call up PLUs. Calling up via PLU key (factory setting, operator setup Step 7 = OFF) 1. Place the item on the scale Enter the corresponding PLU number and press the PLU key. Unit price and price to pay are displayed. 3. Remove the item from the scale. All displays return to 0. Calling up PLU automatically (operator setup Step 7 = ON) 1. Place the item on the scale Enter the corresponding PLU number. The PLU is called up automatically. Unit price and price to pay are displayed. 3. Remove the item from the scale. All displays return to 0. Order number OHAUS Operator Manual Aviator

14 Operation Using PLU preset keys You can save the most important PLUs to the keys in the left-hand key field. Depending on the setting of operator setup Step 14, one or two PLUs can be assigned to a PLU preset key. PLU preset keys with one PLU (operator setup Step 14 = OFF) Storing one PLU to a preset key 1. Enter the unit price (price/kg) or recall PLU. M1 2. Press and hold the desired preset key, e.g., M1, until a long beep can be heard. Two short beeps indicate that the data has been stored. Calling up PLUs with preset keys 1. Place the item on the scale. M1 2. Press the corresponding preset key, e.g., M1. Unit price and price to pay are displayed. 3. Remove the item from the scale. All displays return to OHAUS Operator Manual Aviator 7000 Order number

15 PLU preset keys with two PLUs (factory setting, operator setup Step 14 = ON) 0 9 Storing two PLUs to a preset key 1. Enter the unit price (price/kg) or recall PLU of the first PLU to be assigned to the preset key. M1 2. Press and hold the desired preset key, e.g., M1, until a long beep can be heard. Two short beeps indicate that the data has been stored Enter the unit price (price/kg) or recall PLU of the second PLU to be assigned to the preset key. M1 M1 l2 4. Press and hold the desired preset key, e.g., M1, until a long beep can be heard. 5. Immediately press the desired preset key again, e.g., M1. L2 is displayed and two short beeps indicate that the data has been stored. Calling up PLUs with preset keys 1. Place the item on the scale. M1 2. To call up the first PLU, press the corresponding preset key once, e.g., M1. Unit price and price to pay of the first PLU are displayed. or M1 M1 To call up the second PLU, press the corresponding preset key twice, e.g., M1, M1. Unit price and price to pay of the second PLU are displayed. 3. Remove the item from the scale. All displays return to 0. Order number OHAUS Operator Manual Aviator

16 Operation 3.3 Using tare You fill containers with your products or customers bring their own container. The tare function makes sure that only the goods are entered and paid. If you know the weight of your containers, you can enter the tare weight via keyboard. So you do not have to tare the empty container. Taring an empty container 1. Place the empty container on the scale. 2. Press the Tare key. The weight display is reset to kg and the NET symbol appears. The tare weight is displayed in the bottom line of the display. 3. Fill the container with the goods to be weighed. 4. Carry out pricing as described above. 5. Remove the container from the scale. All displays return to 0. Keyboard tare Input the known tare value and press the Tare key. The input tare value is displayed in the bottom line of the display and the PT cursor is lit. The weight display shows the negative tare value. 2. Place the item with container or wrapping material onto the scale. 3. Carry out pricing as described above. 4. Remove the item with container or wrapping material from the scale. All displays return to OHAUS Operator Manual Aviator 7000 Order number

17 3.4 Zeroing Due to soiling on the weighing pan or unfavourable external influences, it is possible that the weight display of an unloaded weighing pan may no longer be kg. In such cases, the scale must be reset to zero. The maximum allowed deviation to be compensated by zeroing is kg +/- 2 % of the weighing range. Press the Zero key kg The weight display is set to zero. 3.5 By-count operation With the by-count function, you can price non-weighing items, e.g., in the bakery department Enter the unit price. x 2. Press the X key to call up the by-count function. The by-count icon is displayed Enter the number of items (1 99). The price to pay is displayed. The unit price is stored until by-count operation is ended. Use the C key to leave by-count operation. Order number OHAUS Operator Manual Aviator

18 Operation 0 9 x By-count operation (US version) With the by-count function, you can price non-weighing items, e.g., in the bakery department. Pricing can base on a deal quantity of, e.g., 3 pieces. 1. Enter the deal quantity (1 99). 2. Press the X key to call up the by-count function. The by-count icon is displayed Enter the price per deal quantity. 4. Confirm with the Enter (On/Off) key Enter the number of items (1 99). The price to pay is displayed. The unit price is stored until by-count operation is ended. Use the C key to leave by-count operation. 3.6 Accumulating This functionality is only legal in certain regions or if the weighing system is connected to an external printer. 1. Place the first item on the scale. 2. Carry out pricing as described above. TOTal 1 3. Press the Enter (On/Off) key. The total price to pay and the number of items is displayed. 4. Remove the item and press the Enter (On/Off) key again. The weight display is shown. 5. Repeat steps 1 to 4 for more items. TOTal 5 6. To finish the transaction, press the Enter (On/Off) key. The total price to pay and the number of items is displayed. 7. To clear the total, press and hold the C key. The total is cleared. If a printer is connected, a printout can be generated by pressing the Enter (On/Off) key twice. After printing, the total is cleared automatically. 18 OHAUS Operator Manual Aviator 7000 Order number

19 3.7 Change function Your scale is able to calculate the amount of change. Single item 1. Carry out pricing as described above. pay 09 chg 2. Press the Change key. The total price to pay is displayed. 3. Enter the customer s payment and press the FIX key. The amount of change is displayed. 4. Press the C key to return to normal weighing mode. Multiple items 1. Carry out accumulating as described above. pay 09 chg 2. When the total is displayed press the Change key. The total price to pay is displayed. 3. Enter the customer s payment and press the FIX key. The amount of change is displayed. 4. Press the C key to finish the change function. 5. Clear total as described above. Order number OHAUS Operator Manual Aviator

20 Operation 3.8 Fix unit price and/or tare In normal operation, unit price and tare weight if applicable arecleared when the item is removed from the scale. For weighing and pricing, several samples of the same PLU, e.g., for prepacking or sweet sales, you can fix unit price and/or tare. Fixing price and tare weight 1. Tare the container as described above. 2. Place the first sample on the scale. 3. Carry out pricing as described above. 4. Press the FIX key. When removing the item from the scale, the unit price and tare are still displayed e/kg 8,75 e 5. Place the next sample on the scale. The price to pay is displayed. 6. Remove the item from the scale. 7. Repeat steps 5 and 6 for more samples of the same unit price and tare. 8. Press the FIX key again to return to normal weighing mode. To fix the price only, just begin with step 2. To fix the tare weight only, just leave out steps 2 and OHAUS Operator Manual Aviator 7000 Order number

21 3.9 Hold function When using the hold function, the price to pay is kept in the display when the item is removed from the scale. 1. Place the item on the scale. 2. Carry out pricing as described above. 3. Press and hold the Hold (FIX) key until a long beep can be heard. Weight and unit price are cleared, the price to pay and "Hold" are displayed. 8,75 e 4. When removing the item from the scale, the price to pay is still displayed. 5. To return to normal weighing mode, press and hold the Hold key again until a long beep can be heard Weighing with 100 g (1/2 lb / 1/4 lb) price unit For many products, customers are used to a price per 100 g (1/2 lb / 1/4 lb). This function is only available if permitted by the national W & M regulations. 1. Place the item on the scale. 100 g 2. Press the 100 g (1/2 lb / 1/4 lb) key. The icon 100 g (1/2 lb / 1/4 lb) is displayed Enter the unit price per 100 g (1/2 lb / 1/4 lb). The unit price per 100 g (1/2 lb / 1/4 lb) and the price to pay are displayed. 4. Remove the item from the scale. All displays return to g (1/2 lb / 1/4 lb) mode stays active until the 100 g (1/2 lb / 1/4 lb) key is pressed again. Order number OHAUS Operator Manual Aviator

22 3.11 Switching weighing unit between kg and lb This function is only available if permitted by the national W & M regulations. Operation 1B 1. Carry out pricing as described above. 2. Press the Units key until a long beep is can be heard. The weight is displayed in the second weight unit. kg 3. Press the Units key again until a long beep can be heard to return to the first weight unit Displaying the price to pay in EURO Depending on the setting of operator setup Step 10, the price to pay can be converted, e.g., from EURO to the old local currency. This function is only available if permitted by the national W & M regulations. 1. Carry out pricing as described above. kr eur 2. Press the EUR key. The price to pay is displayed in the second currency. 3. Press the EUR key again to return to the first currency Backlight function If the light of the environment is not bright enough to get a clear reading from the display, the backlight can be switched on. Switching backlight on/off Press and hold the C key until a long beep can be heard. The backlight is switched on/off. When the scale is not used for 15 seconds, the backlight automatically switches off. When a weight is placed on the scale or when a key is pressed, the backlight switches on again. 22 OHAUS Operator Manual Aviator 7000 Order number

23 3.14 Ticket printing Your scale provides an interface to connect a printer. For ticket printing, operator setup Step 16 must be set to "1" Ticket without VAT For ticket printing without VAT, operator setup Step 21 must be set to "OFF". 1. Carry out accumulating as described above. TOTal 5 2. To finish the transaction, press the Enter (On/Off) key. The total price to pay and the number of items are displayed. 3. If desired, enter the amount of change as described above. 4. To initiate printing, press the Enter (On/Off) key twice. 5. Press the C key to cancel the transaction. Printout example TickNr : PLU TEXT kg (pcs) /kg(pcs) PLU Preset Non PLU Total Cash Change 4.92 Order number OHAUS Operator Manual Aviator

24 Ticket with VAT For ticket printing with VAT, operator setup Step 21 must be set to "ON" factory setting). Operation M9 M12 Storing VAT on a key To store a VAT on the keys M9 to M1, operator setup Step 22 must be set to "1". 1. Press and hold one of the keys M9 to M12 until a long beep can be heard Enter VAT rate and confirm with the Enter (On/Off) key. E.g., enter 7.00 for VAT rate 7%. M9 M12 TOTal 5 Printing a ticket with VAT 1. Carry out pricing as described above. 2. Press the corresponding VAT key (M9 to M12). 3. Repeat steps 1 and 2 for further items. 4. To finish the transaction, press the Enter (On/Off) key. The total price to pay and the number of items are displayed. 5. If desired, enter the amount of change as described above. 6. To initiate printing, press the Enter (On/Off) key twice. 7. Press the C key to cancel the transaction. 24 OHAUS Operator Manual Aviator 7000 Order number

25 Printout example TickNr : PLU TEXT kg (pcs) /kg(pcs) PLU Preset Non PLU Total Tax 7.00 % 0.72 Tax % 0.85 Cash 20, Change Printing reports Printing sales report M5 Press the report button M5 and confirm with the Enter (On/Off) key. The sales report is printed. delete When printing is finished you are asked if you want to delete the sales report. Sales report example Sale Report Report number 25 Start time :53 To time :02 Item kg/pcs/time By Weight By Count PLU Sales Non PLU Sales Total Tax Order number OHAUS Operator Manual Aviator

26 Printing Log report Operation M5 M5 delete 1. Press the report button M5 twice and confirm with the Enter (On/Off) key. 2. Select the range of transactions to be printed. The log report is printed. When printing is finished you are asked if you want to delete the transactions. Log report example Sale Log :10 Ticket number 25 Item kg/pcs/time PLU Preset Non PLU Sale Log :13 Ticket number 26 Item kg/pcs/time PLU Non PLU Preset OHAUS Operator Manual Aviator 7000 Order number

27 4 Operator setup 4.1 Setup operation Entering operator setup (press and hold) set 1 op step 01 off 1. Press and hold the Menu (PLU) key until a long beep can be heard. SET 1 OP is displayed for "Operator Setup" 2. Press the Enter (On/Off) key to enter operator configuration. The first operator setup step and its current setting are displayed Navigation in the setup Selecting setup step step 01 step 02 step 05 step 04 To move to another setup step, use the Arrow down (Tare) key or Arrow up (Zero) key. In the line below, the current setting of the step is displayed. Changing settings on off on To toggle between the settings of a setup step, use the Enter (On/Off) key. When moving to another setup step, the selected setting is confirmed Ending setup save set 1 op save abort kg 1. Press the Menu (PLU) key to leave operator setup steps. 2. Press the Menu (PLU) key again to leave the setup mode. SAVE is displayed. 3. If you do not want to save, use the Enter (On/Off) key to toggle between SAVE and ABORT. 4. Press the Menu (PLU) key a third time to return to the weighing mode. Order number OHAUS Operator Manual Aviator

28 4.1.4 Example: Setting digital filter to low (operator setup Step 8 = 0) Operator setup (press and hold) set 1 op step 01 off step 08 2 step Press and hold the Menu (PLU) key until a long beep can be heard. SET 1 OP is displayed for "Operator Setup". 2. Press the Enter (On/Off) key to enter operator configuration. The first operator setup step and its current setting are displayed. 3. To move to setup Step 8, press the Arrow down (Tare) key repeatedly until Step 08 with its current setting is displayed. 4. To change the setting of setup Step 8, press the Enter (On/Off) key repeatedly until the setting is kg 5. End setup by pressing the Menu (PLU) key three times. 4.2 Operator setup overview Factory settings are indicated in bold print. No. Setting Description 1 Reset ON Reset operator setup functions to factory settings OFF Do not reset operator setup functions 2 Beeper ON Beep when a key is pressed OFF No sound when a key is pressed 3 Backlighting ON Backlighting on OFF Backlighting off 4 Power off / sleep 0 Both disabled, power off and sleep function 1 No sleep funktion, automatic power off after 30 minutes of non-use 2 Sleep function after 5 minutes of non-use, no automatic power off 3 Sleep function after 5 minutes of non-use, automatic power off after 30 minutes of non-use 4 Sleep function after 15 minutes of non-use, no automatic power off 5 Sleep function after 15 minutes of non-use, automatic power off after 30 minutes of non-use 28 OHAUS Operator Manual Aviator 7000 Order number

29 No. Setting Description 5 Auto clear tare ON Automatic clearing of the tare weight when the load is removed from the platform OFF No automatic clearing of the tare weight 6 Prepack / fix mode ON Prepack / fix mode enabled OFF Prepack / fix mode disabled 7 Auto PLU ON Find PLU as soon as a number is entered OFF Find PLU after pressing the PLU key 8 Digital filter 0 Low digital filtering 1 Medium digital filtering 2 High digital filtering 9 Charging function ON Battery charging function enabled OFF Battery charging function disabled To change charging function you are asked to enter a passwort: Function keys 0 Function keys disabled 1 Function keys enabled 11 PLU ON Storing PLUs enabled OFF Storing PLUs disabled 12 By-count operation ON By-count operation enabled OFF By-count operation disabled 13 Euro 1 Only the local currency is displayed 2 You are asked to enter the conversion rate from the local currency into EUR. When pressing the EUR key, the local currency is converted into EUR. 3 You are asked to enter the conversion rate from EUR into the local currency. When pressing the EUR key, EUR is converted into the local currency. 4 Only EUR is displayed. Order number OHAUS Operator Manual Aviator

30 Operator setup No. Setting Description 14 Two PLUs in one preset key ON Two PLUs can be preset in one preset key OFF Only one PLU can be preset in a preset key 15 Communication port 0 RS232 1 USB 16 Communication type 0 Protocol transfer to a connected computer 1 Printout on a connected printer 17 Ticket language 0 English 1 French 2 German 3 Spanish 4 Italian 18 RS232 communication speed bps bps bps bps bps bps bps 19 Communication format 0 7 data bits, parity even, 1 stop bit 1 7 data bits, parity odd, 1 stop bit 2 7 data bits, no parity, 1 stop bit 3 8 data bits, no parity, 1 stop bit 4 7 data bits, parity even, 2 stop bits 5 7 data bits, parity odd, 2 stop bits 6 7 data bits, no parity, 2 stop bits 7 8 data bits, no parity, 2 stop bits 30 OHAUS Operator Manual Aviator 7000 Order number

31 No. Setting Description 20 Price computing protocol type 0 CAS 1 Avery Berkel 2 Dialog 06 3 L2 Mettler Toledo 4 Anker 5 Dialog 02/04 6 NCI Protocol 21 VAT ON Price is with VAT OFF Price is without VAT 22 VAT key 0 VAT key disabled 1 VAT key enabled 23 PLU tare ON Storing unit price and tare weight in the PLU OFF Storing unit price only in the PLU 4.3 Setting date and time (press and hold) set 1 1. Press and hold the Menu (PLU) key until a long beep can be heard. op set 5 setting 2. Press the Arrow down (Tare) key repeatedly until SET 05 SETTING is displayed. year Press the Enter (On/Off) key to set the year. 4. Use the Arrow down (Tare) key or Arrow up (Zero) key to change the year. month 5. Repeat steps 3 and 4 to set month, day, hour, minute and second kg 6. End setup by pressing the Menu (PLU) key three times. Order number OHAUS Operator Manual Aviator

32 5 What do you do if.? What do you do if.? General If the scale shows an error message, proceed as follows: 1. Turn off the scale and wait for approx. 5 seconds. 2. Turn on the scale. 3. If the error message is still displayed, refer to the error message list. Error message list Error Cause Remedy E11 RAM error Call service technician E16 ROM error Call service technician E18 EEPROM error Call service technician E34 PLU No. too high Enter PLU No. from 1 to 99 No PLU PLU not found Store PLU nnnnnn Overload Reduce load uuuuuu Load too small Re-zero the scale 32 OHAUS Operator Manual Aviator 7000 Order number

33 6 Technical data and accessories 6.1 Technical data Scale data Max. load / incrments Compact versions: 3 kg / 1 g, 12 kg / 2 g, 15 kg / 5 g, 30 kg / 10 g Tower versions: 6 kg / 2 g, 15 kg / 5 g Display Weight display 6 digits Unit price display 6 digits Total price display 6 digits Ambient conditions Operating temperature 10 C to +40 C Storage temperature 25 C to +50 C Electrical data Power supply 12 V DC Power consumption 50 ma Plug-in adapter In: 230 V AC 50 Hz Out: 12 V DC / 800 ma Charging current 500 ma NiMH battery capacity 7000 mah Interface 1 connector on the underside RS232C or USB, depending on the interface cable 6.2 Accessories The following optional accessories are available from your sales representative: Weighing platform cover Scale cover POS connector RS232 POS connector USB External printer Deep bowl Rechargeable NiMH batteries Printer cable Order number OHAUS Operator Manual Aviator

34 7 Appendix Appendix 7.1 Disposal In accordance with the requirements of European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE), this device may not be disposed of with domestic refuse. This also applies for countries outside the EU in accordance with their respective national regulations. Please dispose of this product in accordance with local regulations for the separate collection of waste electrical and electronic equipment. Should you have any questions, please contact the corresponding authorities or the dealer from whom this device was purchased. If this device is passed on (for example for further private or commercial/ industrial use), this regulation is also to be passed on. Many thanks for your contribution to the protection of the environment. Battery disposal Batteries contain heavy metals and therefore cannot be disposed of in the domestic refuse. Observe local regulations on the disposal of materials which are hazardous to the environment. 34 OHAUS Operator Manual Aviator 7000 Order number

35 Order number OHAUS Operator Manual Aviator

36 Subject to technical changes 12/2010 Ohaus Corporation Printed in Switzerland Order number