Company Overview.

Size: px
Start display at page:

Download "Company Overview."

Transcription

1

2 Company Overview About DME PROLINK by ECS Global Wire & Cable ECS was founded in North America over 30 years ago with a vision for innovation and development. Experiencing tremendous growth, we opened our doors in Dubai in 2004 to establish our international presence. ECS Global Wire & Cable is leading vendor of the most comprehensive range of Structured cabling products under brand name DME PROLINK. Known for quality product, customer satisfaction, speedy delivery, and efficient and friendly customer service, ECS continues to grow its customer base across Canada, Middle East and African region. Today we have over fifteen offices internationally, with a custom-built 7,400 m² as our Middle East Headquarters located in Jebel Ali Free Zone. This high-tech, weather-safe facility is used to service the Middle East, North Africa and the Caspian Independent States markets. Our facility is Leed certified with Silver Level by the U.S Green Building Council in the Leed Green Building Rating System and verified by the Green Building Certification Institute. ECS Global Middle East Headquarters, JAFZA, UAE Advantages with ECS Global We stock an extensive array of communication cables complimented by a comprehensive collection of quality accessories. In addition to our product portfolio, we offer design, engineering and project management services to serve your every need. As a global company, we are committed to searching the globe for the most novel products and technologies.. Quality Policy & Mission Statement To deliver high quality specialty cables & application solutions and to satisfy our Customer s demands in the fast growing market. ECS will constantly strive to cultivate close working relationships with emphasis on planning, communicating & constructive feedback system, within our Company, with our Customers & our strategic Partners & seek continual improvement. ECS is and always will be committed to comply with all legal requirements. ECS maintains, and constantly upgrades highperforming and cost effective product lines. Stringent quality control procedures are in place to ensure that DME PROLINK products are inspected and/or tested to comply with strict standards whenever applicable. 1

3 Project Response Team As the world continues to develop at a record pace, projects have become more complicated and timelines more aggressive. Projects are also growing in scale, creating additional challenges and opportunities. To respond to this increasing demand, ECS Global has developed a qualified Project Response Team. The Project Response Team assists customers with rapid response, knowledgeable selection, reliable sourcing, competitive pricing and procurement expertise. This dedicated team applies a proven approach to serve as a resource for our customers, helping them to meet their each and every wire and cable needs. Cable Management ECS now offers a full cable management package involving planning, design, procurement, expediting, storage, distribution and documentation. We are key drivers in the market and through technological advancement and a network of global partners, continually search for unique, innovative and progressive products to meet the evolving needs of our customers. Value-added service Our new and enhanced Middle East Headquarters & Distribution Facility was designed to specifically assist customers with inventory management for ongoing projects. Our project experience enables us to assist clients with cost control, inventory management, and supply and delivery of products for ongoing projects. This value-added service helps to meet clients project deadlines by ensuring continuous construction operation.

4 Management System as per ISO 9001:

5 BICSI Corporate Member ECS is a proud BISCI corporate member. ECS / DME PROLINK has participated in BICSI trade shows as an exhibitor. What is BICSI? BICSI is a professional association supporting the advancement of the information and communications technology (ICT) community. ICT covers the spectrum of voice, data, electronic safety & security, project management and audio & video technologies. It encompasses the design, integration and installation of pathways, spaces, optical fiber- and copper-based distribution systems, wireless-based systems and infrastructure that supports the transportation of information and associated signaling between and among communications and information gathering devices. BICSI provides information, education and knowledge assessment for individuals and companies in the ICT industry. BICSI serves nearly 23,000 ICT professionals, including designers, installers and technicians. These individuals provide the fundamental infrastructure for telecommunications, audio/video, life safety and automation systems. Through courses, conferences, publications and professional registration programs, BICSI staff and volunteers assist ICT professionals in delivering critical products and services, and offer opportunities for continual improvement and enhanced professional stature. Headquartered in Tampa, Florida, USA, BICSI membership spans nearly 100 countries. ECS Technical team is certified by BICSI with a number of its members holding the RCDD (Registered Communication Distribution Designer) credential. The RCDD is one of the highest design credentials in the information and communications technology (ICT) industry, recognized worldwide.. The RCDD status conveys instant advantages over the competition: A professional designation of excellence A highly regarded status recognized and mandated by many private and state organizations A noted mark of design knowledge valued internationally An indication of experience and knowledge known throughout the ICT industry An RCDD is critical in the building design process. 3

6 Catalog Contents Certifications 3 rd Party Product Certification Section A: Copper Cables Category 3, 100 Pair Unscreened Twisted Pair (U/UTP) Indoor cable with PVC sheath A1 Category 3, 10 Pair Unscreened Twisted Pair (U/UTP) Outdoor cable with PE sheath A3 Category 3, 25 Pair Unscreened Twisted Pair (U/UTP) Outdoor cable with PE sheath A5 Category 6, 4-Pair Unscreened Twisted Pair (U/UTP) LSZH cable A7 Category 6, 4-Pair Unscreened Twisted Pair (U/UTP) PVC cable A11 Category 6, 4-Pair Foiled Twisted Pair (F/UTP) LSZH cable A15 Enhanced Category 6, 4-Pair Unscreened Twisted Pair (U/UTP) LSZH cable A18 Category 6A, 4-Pair Unscreened Twisted Pair (U/UTP) LSZH cable A21 Category 6A, 4-Pair Foiled Twisted Pair (F/UTP) LSZH cable A24 Category 6A, 4-Pair Screened Twisted Pair (F/FTP) LSZH cable A27 Section B: Copper Patch Leads Copper Flat Patch Lead, Category 6, Unshielded, PVC, 10cm B1 Copper Patch Lead, Category 6, Unshielded, LSZH B3 Copper Patch Lead, Category 6A, Shielded, LSZH B5 Section C: Modular Jacks Keystone Category 6, RJ45 Modular Jack, Unshielded, F-Tool Compatible C1 Keystone Category 6, RJ45 Shuttered Modular Jack, Unshielded, F-Tool Compatible C3 Keystone Category 6A, RJ45 10G Modular Jack, Shielded, Tool Less C5 Section D: Copper Patch Panel 25 Port Category 3, Voice Patch Panel, Tray Type, 1RU D1 24 Port Category 6 Unshielded, Unloaded Patch Panel, 1RU D3 24 Port Category 6 Unshielded, Loaded Patch Panel, 1RU D4 24 Port Category 6A Shielded, Unloaded Patch Panel, 1RU D6 Section E: 110 Connectivity System Category 5e / Category 3 IDC Wiring Block Base E1 Category 5e / Category 3 IDC Connecting Block E3 Section F: Male Plugs Category 6, RJ45 Unshielded Male Plug (8-Pin) F1 Section G: Line Jack Units / Feed Through Coupler Line jack Units for Terminating Telephone Lines G1 Category 6, RJ Feed Through Coupler G2 4

7 Catalog Contents Section H: Fiber Optic Cables Fiber Optic Indoor cable, Armored, MLT/MRT, Single mode, Anti Rodent, G.652D, FR-PVC, Black H1 Fiber Optic cable, Indoor/Outdoor Distribution Tight Buffered H7 Fiber Optic cable, Indoor Distribution Tight Buffered H16 Duct Fiber optic Outdoor Armored Cable, MLT, OS2, G.657A1, PE sheath H23 Duct Fiber optic Outdoor Dielectric Cable, MLT, OS2, G.652D, LSZH H33 Fiber Optic Outdoor Armored cable, MLT, with 2 Ripcords, Polyester/ AL Tape, Steel CST, OS2, G.652D, PE sheath H39 Fiber Optic Drop cable Indoor Single mode with KFRP for FTTx H45 Fiber Optic Drop cable Indoor Single mode (Steel Wire) for FTTx H49 Fiber Optic Drop cable Outdoor Single mode (Steel Wire) for FTTx H52 Fiber Optic Outdoor cable, Unarmored, MLT/MRT, Single mode, Jelly Filled G.52D, PE, Black H57 Fiber Optic Indoor/Outdoor Dielectric cable, CLT, Jelly Filled, with Glass Yarn, OS2, G.652D, LSZH H63 Fiber Optic Air Blown Micro cable, Central Tube, OS2, G.652D, HDPE H67 Fiber Optic Air Blown Mini cable, MLT, OS2, G.652D, HDPE H71 Section J: Fiber Optic Patch Panel and Splitter Panel Fiber Optic Patch Panel, 19 Rack Mount J1 Fiber Optic Patch Panel, 19 Rack Mount, Loaded (SC/APC) J3 Fiber Optic Splitter Panel, 19 Rack Mount, LC/APC, 2: J6 Fiber Optic Splitter Panel, 19 Rack Mount, SC/APC, 2: J11 Section K: Fiber Optic Patch Cord Fiber Optic Patch cord, Simplex, SC/APC-SC/APC, OS2, G.652D, LSZH K1 Fiber Optic Patch cord, Simplex, SC/PC-FC/PC, OS2, G.652D, LSZH K5 Fiber Optic Patch cord, Simplex, SC/APC-LC/APC, OS2, G57A2, LSZH K8 Fiber Optic Patch cord, Duplex, LC/APC-LC/APC, Single mode OS2, LSZH, G.652D K12 Fiber Optic Patch cord, Duplex, LC/UPC-LC/UPC, Multimode OM3/OM4, LSZH K16 Fiber Optic Patch cord, Duplex, LC/UPC-LC/UPC, Multimode OM4, LSZH K18 Section L: Optical Distribution Frame (ODF) High Density Optical Distribution Frame (HD ODF) L1 Fiber Optic Mini ODF 48 Fiber Capacity / with Splice Tray L3 Fiber Distribution Hub, High Density FDH L5 Section M: FO Enclosures Fiber Optic Outlet 2 Port, with 1 SC/APC Adapter, 1 Plastic Bush, No Pigtails M1 Fiber Optic Outlet, 2 Port, Unloaded M3 Fiber Optic Outlet, 4 Port Micro ODF (Unloaded) M4 Fiber Optic Outlet, 4 Port Micro ODF (Loaded) SC/APC and LC/APC M5 Section N: FO Accessories Fiber Optic Pigtail, SC/UPC & LC/UPC, OM3, LSZH N1 Fiber Optic Pigtail, LC/APC, OS2, G.657A1/A2, LSZH N5 Fiber Optic Pigtail, SC/APC, OS2, G.657A1, LSZH N10 Fiber Optic Adapter LC/APC, Single mode, Duplex N14 Fiber Optic Adapter, LC/UPC, Multimode, Duplex N15 Fiber Optic Adapter, SC/APC, Single mode, Simplex N16 Splice Protection Sleeves, For Single Fiber N17 Splice Protection Sleeves, For Ribbon Fiber N18 Fiber Optic Connector, SC/APC, Single mode, FIC N19 5

8 Catalog Contents Catalog Contents Section P: FO Accessories / Patch Cord Drawer Fiber Optic Splitter Modules for FDH P1 Fiber Optic Ribbon Fan out cord P3 Plastic Optical Fiber (POF) cable for Special Applications P5 Fiber Optic Patch cord Drawer, 19 Rack mount P6 Section Q: Coaxial Cables and Components Coaxial cable RG6, 75 Ohm Q1 Coaxial cable RG11, 75 Ohm Q2 RG59 + 2DC Siamese Coaxial Cable 0.81mm CCA mm FPE + Bonded AL Foil + 90% CCA Braiding + 6.0mm PVC +18AWG Power Cable (7*0.37mm CCA + 1.8mm PE Red and Black), PVC Q3 Coaxial Connector RG6, 75 Ohm Q4 Section R: Cabinets Wall Mount Cabinet R1 Floor Mount Cabinet Front Glass Door Rear Solid Metal Door R4 Floor Mount Cabinet Perforated Doors, IP R8 Wall Mount Cabinet Front Glass Door with 12 Port Patch Panel and Mounting Plate R12 Flush Mount Cabinet - Perforated Metal Door with 12-Port Patch Panel 12U, 425mm (W) x 120mm (D) R14 Flush Mount Cabinet - Front Glass Door with Mounting Plate 12U, 600mm (W) x 150mm (D) R17 Surface Mount Cabinet - Front Glass Door 12U, 600mm (W) x 150mm (D) R19 Wall Mount Cabinet - Front Glass Door with 19 Mounted Shelf 12U, 600mm (W) x 300mm (D) R21 Wall Mount Cabinet - Front Glass Door with 19 Mounted Shelf 12U, 600mm (W) x 350mm (D) R23 Section S: Multimedia Snap-In Multimedia Connector S1 Section T: Cable Management Fiber Optic Raceway System T1 19 Cable Manager, Finger Type with Metal Cover T13 19 Cable Manager, Rack Mount T14 Section U: General Accessories Face Plate, Angled Single Port with shutter U1 Face Plate, Angled Dual Port with shutter U2 French Face Plate compatible with French adapters U3 Floor Box Mount, Angled Adapter with shutter for RJ45 Modular Jacks U4 Surface Mount Box for Telecommunication outlet U5 French Angled Single Port Adapter with shutter & Icon U9 French Straight Single Port Adapter with shutter & Icon U9 Universal Face Plate Adapter Single Port with shutter U10 Power Distribution Unit (PDU), 19 Rack Mount U11 Stainless Steel Snap-In Face Plate, Unloaded U12 Section V: Industrial Solution & Tools IP67 Surface Box Quad and Dual Port V1 Copper Termination F-Tool V2 Copper Termination Punch Down Tool V3 6

9 Catalog Contents Section W: Intelligent Solution DME ProPatch Intelligent Solution for Fiber and Copper W1 DME Patch+ Intelligent RFID Patch Management W5 Section Y: Standards Y1 Section Z: Technical Reference Distance supported on Optical Fiber Z1 What is OS1 and OS2? Z2 IP Rating Z4 Section AA: Glossary Terms AA1 7

10 Certifications Certifications 3 rd Party Product Certification DME PROLINK products are tested and certified by International 3rd Party Testing laboratories like UL, Intertek and Delta. 8

11 Certifications 9

12 Certifications 10

13 Our DME PROLINK Copper solutions are fast, reliable and BUILT TO LAST

14 DME PROLINK Category 3, 100 Pair, Unscreened Twisted Pair (U/UTP) Indoor cable, with PVC sheath A B No. of Pairs Polyester Tape Ripcord PVC Jacket D C A: 1P-25P is tied up with White/Blue Identification tape B: 26P-50P is tied up with White/Orange Identification tape C: 51P-75P is tied up with White/Green Identification tape D: 76P-100P is tied up with White/Brown Identification tape Product Description DME PROLINK s Category 3 U/UTP Multi-pair cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 3 specifications. DME PROLINK s Category 3 U/UTP Multi-pair cable is designed for Voice Backbone and related applications. Each cable consists of 200 colour coded 0.50mm HDPE insulated conductors. Each conductors are twisted together to form 100 pairs. DME PROLINK s CAT3 cable is designed for quick and easy installation where no special tools are required. CAT3 cable is supplied in Drum packaging for fast, snag free installation. Features & Benefits Performance exceeding Category 3 specifications of 16MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 0.50mm, Solid Bare Copper Polyvinyl Chloride (PVC) Sheath 25 Years System Warranty Specification Overall Diameter (mm) 19.6 ± 0.3 Sheath Thickness (mm) 1.2 ± 0.2 Standards Complied and Verified for Category 3 Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 EN YD/T1019 Sheath Surface Sheath Material Insulation Material Clean, Frap, Satiation PVC (RoHS Compliant) HDPE A1

15 DME PROLINK Category 3, 100 Pair, Unscreened Twisted Pair (U/UTP) Indoor cable, with PVC sheath Insulation Overall diameter (mm) 0.88 ± 0.02 Conductor Diameter (mm) 0.50 (± 0.005) Conductor Material Impedance 1-16 MHz Delay Skew 1-16 MHz 45 Max. DC Resistance (Ω/100m) 9.5 Max. DC Conductor Resistance Unbalance (%) 5.0 Rip cord Drain Wire Shield Solid Bare Copper 100 ± 15 Ω Yes No Polyester Tensile Strength (Mpa) 13.5 Before Aging Elongation (%) 150 Aging Period ( x Hrs) After Aging Elongation (%) 125 Cold bend (-20 ± 2 x 4h) Installation Temperature Range Operating Temperature Range 100 x 24h x 7d No visible cracks -20 C to +50 C 30 C to +50 C Packing Length (Meters) 305 ± 1.5 Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100 m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay (Max. ns) Part Number D UU3PVGY 100-Pair Multicore Indoor Backbone, CAT3, U/UTP Cable, 305m, PVC Sheath, 0.50mm, Grey A2

16 DME PROLINK Category 3, 10 Pair, Unscreened Twisted Pair (U/UTP) Outdoor cable, with PE sheath BC Conductor HDPE Polyester Tape Ripcord PE Jacket Product Description DME PROLINK s Category 3 U/UTP Multi-pair cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 3 specifications. DME PROLINK s Category 3 U/UTP Multi-pair cable is designed for Voice Backbone and related applications. Each cable consists of 20 colour coded 0.50mm HDPE insulated conductors. Each conductors are twisted together to form 10 pairs. DME PROLINK s CAT3 cable is designed for quick and easy installation where no special tools are required. CAT3 cable is supplied in Drum packaging for fast, snag free installation. Features & Benefits Performance exceeding Category 3 specifications of 16MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 0.50mm, Solid Bare Annealed Copper Low Density Polyethylene (LDPE) Sheath 25 Years System Warranty Standards Complied and Verified for Category 3 Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 EN YD/T1019 Specification Overall Diameter (mm) 7.8 ± 1.0 Sheath Thickness (mm) 0.90 ± 0.2 Sheath Surface Sheath Material Insulation Material Clean, Frap, Satiation LDPE HDPE A3

17 DME PROLINK Category 3, 10 Pair, Unscreened Twisted Pair (U/UTP) Outdoor cable, with PE sheath Insulation Overall diameter (mm) 0.87 ± 0.03 Conductor Diameter (mm) 0.50 (± 0.01) Conductor Material Impedance 1-16 MHz Delay Skew 1-16 MHz 45 Max. DC Resistance (Ω/100m) 9.5 Max. DC Conductor Resistance Unbalance (%) 5.0 Rip cord Drain Wire Shield Solid Bare Annealed Copper 100 ± 15 Ω Yes No Polyester Tensile Strength (Mpa) 10.0 Before Aging Elongation (%) 350 Aging Period ( x Hrs) After Aging Elongation (%) 300 Cold bend (-20 ± 2 x 4h) Installation Temperature Range Operating Temperature Range 100 x 24h x 10d No visible cracks -20 C to +50 C 30 C to +50 C Packing Length (Meters) 305 ± 1.5 Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100 m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay (Max. ns) Part Number D UU3PEBK 10-Pair Multicore Outdoor Backbone, CAT3, U/UTP cable, 305m, PE Sheath, 0.50mm, Black A4

18 DME PROLINK Category 3, 25 Pair, Unscreened Twisted Pair (U/UTP) Outdoor cable, with PE sheath BC Conductor HDPE Polyester Tape Ripcord PE Jacket Product Description DME PROLINK s Category 3 U/UTP Multi-pair cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 3 specifications. DME PROLINK s Category 3 U/UTP Multi-pair cable is designed for Voice Backbone and related applications. Each cable consists of 50 colour coded 0.50mm HDPE insulated conductors. Each conductors are twisted together to form 25 pairs. DME PROLINK s CAT3 cable is designed for quick and easy installation where no special tools are required. CAT3 cable is supplied in Drum packaging for fast, snag free installation. Features & Benefits Performance exceeding Category 3 specifications of 16MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 0.50mm, Solid Bare Annealed Copper Low Density Polyethylene (LDPE) Sheath 25 Years System Warranty ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 EN YD/T1019 Standards Complied and Verified for Category 3 Cable Performance Specification Overall Diameter (mm) 11.6 ± 0.8 Sheath Thickness (mm) 1.0 ± 0.2 Sheath Surface Sheath Material Insulation Material Clean, Frap, Satiation LDPE HDPE A5

19 DME PROLINK Category 3, 25 Pair, Unscreened Twisted Pair (U/UTP) Outdoor cable, with PE sheath Insulation Overall diameter (mm) 0.87 ± 0.02 Conductor Diameter (mm) 0.50 (± 0.01) Conductor Material Impedance 1-16 MHz Delay Skew 1-16 MHz 45 Max. DC Resistance (Ω/100m) 9.5 Max. DC Conductor Resistance Unbalance (%) 5.0 Rip cord Drain Wire Shield Solid Bare Annealed Copper 100 ± 15 Ω Yes No Polyester Tensile Strength (Mpa) 13.5 Before Aging Elongation (%) 350 Aging Period ( x Hrs) After Aging Elongation (%) 300 Cold bend (-20 ± 2 x 4h) Installation Temperature Range Operating Temperature Range 100 x 24h x 10d No visible cracks -20 C to +50 C 30 C to +50 C Packing Length (Meters) 305 ± 1.5 Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100 m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay (Max. ns) Part Number D UU3PEBK 25-Pair Multicore Outdoor Backbone, CAT3, U/UTP cable, 305m, PE Sheath, 0.50mm, Black A6

20 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable Product Description DME PROLINK s Category 6 U/UTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6 specifications. DME PROLINK s Category 6 U/UTP cable is designed for optimal support of High-Speed data protocols delivering 1 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyethylene insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. These pairs are then put around a central X shaped polyethylene filler/separator which helps in maintaining and enhancing the cable performance. DME PROLINK s CAT6 cable is designed for quick and easy installation where no special tools are required. CAT6 cable is supplied in Reelex packaging for fast, snag free installation. Features & Benefits Performance exceeding Category 6 specifications of 250MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 Third Party Delta EC verified AWG 23, Solid Bare Annealed Copper Low Smoke Zero Halogen Fire rated to IEC Years System Warranty Standards Complied and Verified for Category 6 Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2013 A7

21 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable Supporting Applications 10G BASE-T (Length <50m) 1000BASE-T (Gigabit Ethernet) 100BASE-T (IEEE 802.3) 100BASE-VG-AnyLAN 100 Mbps TP-PMD (ANSI X3T9.5) 10BASE-T (IEEE 802.3) 1.2 Gbps ATM 55/155 Mbps ATM 4/16 Mbps TOKEN RING (IEEE 802.5) Specification Standards Complied and Verified for Category 6 Cable Flammability, Halogen acidity & Smoke Performance IEC [1,2]:2004 IEC [1,2] IEC [1,2] Overall Diameter (mm) 6.0 ± 0.4 Sheath Thickness (mm) 0.55 ± 0.05 Sheath Surface Clean, Frap, Satiation Insulation Material HDPE Insulation Overall diameter (mm) 0.98 ± 0.03 Conductor Diameter (mm) 0.55 (± 0.005) Conductor Material Solid Bare Copper Impedance MHz 100 ± 15 Ω Delay Skew MHz 45 Max. DC Resistance (Ω/100m) 9.5 Max. DC Conductor Resistance Unbalance (%) 5.0 Nominal Velocity of Propagation (NVP) 68% Rip cord Yes Drain Wire No Max. Pulling Force (N) 100 Min. Bend Radius during Installation 8xD (Overall diameter) Min. Bend Radius after Installed 4xD (Overall diameter) Installation Temperature Range -20 C to +50 C Operating Temperature Range 30 C to +50 C Packing Length (Meters) 305 ± m Reel Weight 12.5 Kg Box Dimensions 210mm wide x 420mm high x 420mm deep A8

22 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay (Max. ns) Part Number D0174-UU3LSGY Horizontal Cable, CAT6, U/UTP, 305m, LSZH Sheath, 23AWG (0.57mm), Grey A9

23 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable A10

24 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) PVC Cable Product Description DME PROLINK s Category 6 U/UTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6 specifications. DME PROLINK s Category 6 U/UTP cable is designed for optimal support of High-Speed data protocols delivering 1 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyethylene insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. These pairs are then put around a central X shaped polyethylene filler/separator which helps in maintaining and enhancing the cable performance. DME PROLINK s CAT6 cable is designed for quick and easy installation where no special tools are required. CAT6 cable is supplied in Reelex packaging for fast, snag free installation. Features & Benefits Performance exceeding Category 6 specifications of 250MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 Third Party Delta EC verified AWG 23, Solid Bare Annealed Copper PVC Poly (Vinyl Chloride) Fire rated to IEC Years System Warranty Standards Complied and Verified for Category 6 Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2013 A11

25 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) PVC Cable Supporting Applications 10G BASE-T (Length <50m) 1000BASE-T (Gigabit Ethernet) 100BASE-T (IEEE 802.3) 100BASE-VG-AnyLAN 100 Mbps TP-PMD (ANSI X3T9.5) 10BASE-T (IEEE 802.3) 1.2 Gbps ATM 55/155 Mbps ATM 4/16 Mbps TOKEN RING (IEEE 802.5) Specification Standards Complied and Verified for Category 6 Cable Flammability, Halogen acidity & Smoke Performance IEC [1,2]:2004 IEC [1,2] IEC [1,2] Overall Diameter (mm) 6.0 ± 0.4 Sheath Thickness (mm) 0.55 ± 0.05 Sheath Surface Clean, Frap, Satiation Insulation Material HDPE Insulation Overall diameter (mm) 0.98 ± 0.04 Conductor Diameter (mm) 0.55 (± 0.005) Conductor Material Solid Bare Copper Impedance MHz 100 ± 15 Ω Delay Skew MHz 45 Max. DC Resistance (Ω/100m) 9.38 Max. DC Conductor Resistance Unbalance (%) 5.0 Nominal Velocity of Propagation (NVP) 69% Rip cord Yes Drain Wire No Max. Pulling Force (N) 90 Min. Bend Radius during Installation 8xD (Overall diameter) Min. Bend Radius after Installed 4xD (Overall diameter) Installation Temperature Range -5 C to +50 C Operating Temperature Range 20 C to +70 C Packing Length (Meters) 305 ± m Reel Weight Box Dimensions 255mm wide x 415mm high x 415mm deep A12

26 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) PVC Cable Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay (Max. ns) Part Number D0174-UU3PVGY Horizontal Cable, CAT6, U/UTP, 305m, PVC Sheath, 23AWG (0.57mm), Grey A13

27 DME PROLINK Category 6 Unscreened Twisted Pair (U/UTP) PVC Cable A14

28 DME PROLINK Category 6 Foiled Twisted Pair (F/UTP) LSZH Cable Product Description DME PROLINK s Category 6 F/UTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6 specifications. DME PROLINK s Category 6 F/UTP cable is designed for optimal support of High-Speed data protocols delivering 1 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyethylene insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. These pairs are then put around a central X shaped polyethylene filler/separator which helps in maintaining and enhancing the cable performance. There is an overall foil around the pairs. DME PROLINK s CAT6 cable is designed for quick and easy installation where no special tools are required. Features & Benefits Performance exceeding Category 6 specifications of 250MHz Performance compliance to ISO/IEC 11801, ANSI/TIA-568-C2 and YD/T 1019 AWG 23, Solid Bare Annealed Copper Low Smoke Zero Halogen Fire rated to IEC Years System Warranty Standards Complied and Verified for Category 6 Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2013 A15

29 DME PROLINK Category 6 Foiled Twisted Pair (F/UTP) LSZH Cable Supporting Applications 10G BASE-T (Length <50m) 1000BASE-T (Gigabit Ethernet) 100BASE-T (IEEE 802.3) 100BASE-VG-AnyLAN 100 Mbps TP-PMD (ANSI X3T9.5) 10BASE-T (IEEE 802.3) 1.2 Gbps ATM 55/155 Mbps ATM 4/16 Mbps TOKEN RING (IEEE 802.5) Standards Complied and Verified for Category 6 Cable Flammability, Halogen acidity & Smoke Performance IEC [1,2]:2004 IEC [1,2] IEC [1,2] Specification Overall Diameter (mm) 6.8 ± 0.4 Sheath Thickness (mm) 0.60 ± 0.05 Sheath Surface Clean, Frap, Satiation Insulation Material HDPE Insulation Overall diameter (mm) 1.10 ± 0.04 Conductor Diameter (mm) (± 0.005) Conductor Material Solid Bare Copper Impedance MHz 100 ± 15 Ω Delay Skew MHz 45 Max. DC Resistance (Ω/100m) 9.38 Max. DC Conductor Resistance Unbalance (%) 5.0 Nominal Velocity of Propagation (NVP) 68% Rip cord Yes Drain Wire Yes Max. Pulling Force (N) 100 Min. Bend Radius during Installation 8xD (Overall diameter) Min. Bend Radius after Installed 4xD (Overall diameter) Installation Temperature Range -20 C to +50 C Operating Temperature Range 30 C to +50 C Packing Length (Meters) 305 ± 1.5 A16

30 DME PROLINK Category 6 Foiled Twisted Pair (F/UTP) LSZH Cable Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay (Max. ns) Part Number D0174-FU3LSGY Horizontal Cable, Cat-6, F/UTP, 305m, LSZH Sheath, AWG 23, Grey A17

31 DME PROLINK Enhanced Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable Product Description DME PROLINK s Category 6 U/UTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6 specifications. DME PROLINK s Category 6 U/UTP cable is designed for optimal support of High-Speed data protocols delivering 1 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyolefin insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. These pairs are then put around a central X shaped or cross filler/separator which helps in maintaining and enhancing the cable performance. DME PROLINK s CAT6 cable is designed for quick and easy installation where no special tools are required. CAT6 cable is supplied in Reelex packaging for fast, snag free installation. Features & Benefits Enhanced Performance exceeding Category 6 specifications up to 350 MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 Third Party Delta EC verified AWG 23, Solid Bare Annealed Copper Low Smoke Zero Halogen Fire rated to IEC Years System Warranty Standards Complied and Verified for Category 6 Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2013 A18

32 DME PROLINK Enhanced Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable Supporting Applications 10G BASE-T (Length <50m) 1.2 Gbps ATM 1000BASE-T (Gigabit Ethernet) 55/155 Mbps ATM 100BASE-T (IEEE 802.3) 100 Mbps TP-PMD (ANSI X3T9.5) 100BASE-VG-AnyLAN 4/16 Mbps TOKEN RING (IEEE 802.5) 10BASE-T (IEEE 802.3) Specification Standards Complied and Verified for Category 6 Cable Flammability, Halogen acidity & Smoke Performance EN/IEC IEC [1,2] IEC [1,2] EN [1,2] Overall Diameter (mm) 5.4 Sheath Thickness (mm) 0.5mm Sheath Surface Clean, Frap, Satiation Insulation Material HDPE Insulation Overall diameter (mm) 1 mm Conductor Diameter (mm) 0.57 (± 0.005) Conductor Material Solid Bare Annealed Copper Mean Input Impedance MHz 100 ± 5 Ω Delay Skew MHz 40 Max. Propagation delay (ns@10mhz): 518 Max. DC Resistance 20 C 93.8 Nom. Mutual Capacity (nf/km)@1khz 56 Nominal Velocity of Propagation (NVP) 65% Rip cord / Drain Wire No / No Max. Pulling Force (N) 200 Min. Bend Radius during Installation 8xD (Overall diameter) Min. Bend Radius after Installed 4xD (Overall diameter) Installation Temperature Range -5 C to +50 C Operating Temperature Range 20 C to +70 C Packing Length (Meters) 305 ± m Reel Weight 11.5Kg Box Dimensions 210mm wide x 420mm high x 420mm deep A19

33 DME PROLINK Enhanced Category 6 Unscreened Twisted Pair (U/UTP) LSZH Cable Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) ACR db/100m) * * * For information only Part Number D0178-UU3LSGY Horizontal Cable, CAT6, U/UTP, 305m, LSZH Sheath, 23AWG (0.57mm), Grey A20

34 DME PROLINK Category 6A Unshielded Twisted Pair (U/UTP) LSZH Cable Product Description DME PROLINK s Category 6A U/UTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6A specifications. DME PROLINK s Category 6A U/UTP cable is designed for optimal support of High-Speed data protocols delivering 10 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyolefin Foam-Skin insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. DME PROLINK s CAT6A cable is designed for quick and easy installation where no special tools are required. CAT6A cable is supplied in 305m Drums. Features & Benefits Enhanced Performance meeting Category 6A specifications up to 500 MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 Third Party Delta EC verified AWG 23, Solid Bare Annealed Copper Low Smoke Zero Halogen Fire rated to IEC , IEC C 25 Years System Warranty Standards Complied and Verified for Category 6A Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2012 A21

35 DME PROLINK Category 6A Unshielded Twisted Pair (U/UTP) LSZH Cable Supporting Applications 10G BASE-T 1.2 Gbps ATM 1000BASE-T (Gigabit Ethernet) 55/155 Mbps ATM 100BASE-T (IEEE 802.3) 100 Mbps TP-PMD (ANSI X3T9.5) 100BASE-VG-AnyLAN 4/16 Mbps TOKEN RING (IEEE 802.5) 10BASE-T (IEEE 802.3) Specification Standards Complied and Verified for Category 6A Cable Flammability, Halogen acidity & Smoke Performance EN/IEC IEC [1,2] IEC [1,2] Overall Diameter (mm) 6.9 ± 0.4mm Sheath Surface Clean, Frap, Satiation Sheath Material LSZH (complies RoHS) Insulation Material HDPE Insulation Diameter (mm) 1.03 ± 0.03 Conductor Diameter (mm) 0.57 (± 0.005) Conductor Material Solid Bare Copper Mean Input Impedance MHz 100 ± 5 Ω Delay Skew MHz Max 45 Max. DC Resistance 20 C 9.5 DC Conductor Resistance Unbalance(%) Max 5.0 Nominal Velocity of Propagation (NVP) 69% Ripcord / Drain Wire Yes / No Max. Pulling Force (N) 100 Min. Bend Radius during Installation 8xD (Overall diameter) Min. Bend Radius after Installed 4xD (Overall diameter) Storage Temperature Range 20 C to +70 C Operating Temperature Range 20 C to +70 C Packing Length (Meters) 305 ± 1.5 Carton Dimension (in cm) 40.5 x 40.5 x 21 A22

36 DME PROLINK Category 6A Unshielded Twisted Pair (U/UTP) LSZH Cable Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) Phase Delay ns Part Number D0184-UU3LSGY Horizontal Cable, CAT 6A, U/UTP, 305m, LSZH Sheath, AWG 23, Grey A23

37 DME PROLINK Category 6A Foiled Twisted Pair (F/UTP) LSZH Cable Construction 1 Conductor: 23AWG, Solid Bare Annealed Copper 2 Insulation: Polyolefin 3 Varying short pair lay-length (4 Pairs) 4 Cross Filler 5 Overall Aluminium/Polyester Foil 6 Tinned Copper drain wire 7 Sheath: LSZH Material Product Description DME PROLINK s Category 6A F/UTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6A specifications. DME PROLINK s Category 6A F/UTP cable is designed for optimal support of High-Speed data protocols delivering 10 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyolefin insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. An overall Aluminium/ Polyester foil wrapped around all pairs. DME PROLINK s CAT6A cable is designed for quick and easy installation where no special tools are required. CAT6A cable is supplied in 500m or 1000m spools. Features & Benefits Enhanced Performance meeting Category 6A specifications up to 500 MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 Third Party Delta EC verified AWG 23, Solid Bare Annealed Copper Low Smoke Zero Halogen Fire rated to IEC , IEC C 25 Years System Warranty Standards Complied and Verified for Category 6A Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2012 A24

38 DME PROLINK Category 6A Foiled Twisted Pair (F/UTP) LSZH Cable Supporting Applications 10G BASE-T 1.2 Gbps ATM 1000BASE-T (Gigabit Ethernet) 55/155 Mbps ATM 100BASE-T (IEEE 802.3) 100 Mbps TP-PMD (ANSI X3T9.5) 100BASE-VG-AnyLAN 4/16 Mbps TOKEN RING (IEEE 802.5) 10BASE-T (IEEE 802.3) Specification Standards Complied and Verified for Category 6A Cable Flammability, Halogen acidity & Smoke Performance EN/IEC IEC [1,2] IEC [1,2] Overall Diameter (mm) 7.8mm Sheath Surface Clean, Frap, Satiation Insulation Material Polyolefin Conductor Diameter (mm) 23WG 0.57 (± 0.005) Conductor Material Solid Bare Annealed Copper Mean Input Impedance 100 MHz 100 ± 5 Ω Delay Skew (ns/100m) Max 40 Max. Propagation delay (ns@10mhz): 518 Max. DC Resistance 20 C 95.0 Nom. Mutual Capacity 1KHz 56 Min. Coupling Att MHz 55 Min. Coupling Att MHz 55 20log(f/100) Nominal Velocity of Propagation (NVP) 70% Drain Wire Yes. Tinned Copper (TC) Max. Pulling Force (N) 100 Min. Bend Radius (mm) 32.0 Storage Temperature Range 20 C to +70 C Operating Temperature Range 20 C to +70 C Laying Temperature Range 5 C to +70 C Packing Length (Meters) 500 or 1000 ± 1.5 meters Approx. Weight (kg/km) 58.0 Calorific Value (MJ/m) A25

39 DME PROLINK Category 6A Foiled Twisted Pair (F/UTP) LSZH Cable Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100 m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) ACR db/100m) PS-ACR db/100m) 1* Part Number D0188-FU5LSWT D0188-FU10LSWT Horizontal Cable, CAT 6A, F/UTP, 500m, LSZH Sheath, AWG 23, White Horizontal Cable, CAT 6A, F/UTP, 1000m, LSZH Sheath, AWG 23, White A26

40 DME PROLINK Category 6A Screened Twisted Pair (F/FTP) LSZH Cable Product Description DME PROLINK s Category 6A F/FTP cables are manufactured and tested to the TIA/EIA 568 C2, EN and ISO/ IEC Category 6A specifications. DME PROLINK s Category 6A F/FTP cable is designed for optimal support of High-Speed data protocols delivering 10 Gbps performance to the workstation. Each cable consists of 8 colour coded 23AWG polyolefin Foam-Skin insulated conductors. Each conductors are twisted together to form 4 pairs with varying lengths. Each pairs are then wrapped with Aluminium/ Polyester foil. Then an overall Aluminium/ Polyester foil wrapped around all pairs. DME PROLINK s CAT6A cable is designed for quick and easy installation where no special tools are required. CAT6A cable is supplied in 305m Drums. Features & Benefits Enhanced Performance meeting Category 6A specifications up to 500 MHz Performance compliance to ISO/IEC and ANSI/TIA-568-C2 Third Party Delta EC verified AWG 23, Solid Bare Annealed Copper Low Smoke Zero Halogen Fire rated to IEC , IEC C 25 Years System Warranty Standards Complied and Verified for Category 6A Cable Performance ISO/IEC 11801:2011 (Ed.2.2) ANSI/TIA-568-C2:2009 IEC :2012 (Ed.2.1) EN :2011; EN :2007 including amendment A1:2010 EN :2012 A27

41 DME PROLINK Category 6A Screened Twisted Pair (F/FTP) LSZH Cable Supporting Applications 10G BASE-T 1.2 Gbps ATM 1000BASE-T (Gigabit Ethernet) 55/155 Mbps ATM 100BASE-T (IEEE 802.3) 100 Mbps TP-PMD (ANSI X3T9.5) 100BASE-VG-AnyLAN 4/16 Mbps TOKEN RING (IEEE 802.5) 10BASE-T (IEEE 802.3) Specification Standards Complied and Verified for Category 6A Cable Flammability, Halogen acidity & Smoke Performance EN/IEC IEC [1,2] IEC [1,2] Overall Diameter (mm) 7.6 ± 0.5mm Sheath Surface Clean, Frap, Satiation Insulation Material Skin Foam Skin PE Conductor Diameter (mm) 0.57 (± 0.005) Conductor Material Solid Bare Annealed Copper Mean Input Impedance MHz 100 ± 5 Ω Delay Skew (ns/100m) Max 45 Max. Propagation delay (ns@10mhz): 518 Max. DC Resistance 20 C 95.0 Capacitance (nf/100m) Max. 5.6 Nominal Velocity of Propagation (NVP) 74% Drain Wire Yes. TC 0.45mm Max. Pulling Force (N) 100 Min. Bend Radius during Installation 8xD (Overall diameter) Min. Bend Radius after Installed 4xD (Overall diameter) Storage Temperature Range 20 C to +70 C Operating Temperature Range 20 C to +70 C Packing Length (Meters) 305 ± 1.5 A28

42 DME PROLINK Category 6A Screened Twisted Pair (F/FTP) LSZH Cable Construction Technical Performance Freq. (MHz) RL db) ATTN (Max. db/100 m) NEXT db) PSNEXT db) ELFEXT (ACR-F) db/100m) PSELFEXT (PSACR-F) db/100m) ACR db/100m) PS-ACR db/100m) Part Number D0184-FF3LSGY Horizontal Cable, CAT 6A, F/FTP, 305m, LSZH Sheath, AWG 23, Grey A29

43 DME DME PROLINK Copper 24-Port Flat CAT6 Patch Lead, Loaded CAT6, Patch Unshielded, Panel, 1RU PVC, 10cm Description DME PORLINK s Category 6 Flat Patch Lead reduce crosstalk and system noise. The superior insulation around the 32 gauge (AWG) copper wires attribute to its increased performance. The CAT6 cables can transmit data at 1000 Mbps (~1 Gigabit per second) with a frequency of 250 MHz and suitable for 10BASE-T, 100BASE-TX Fast Ethernet, and 1000BASE-T / 1000BASE-TX (Gigabit Ethernet). Features & Benefits TRANSMISSION PERFROMANCE Unshielded Twisted Pair (UTP) Cable Cross-Section: 1.5mm x 6mm Conductor: 32 AWG Insulation Material: HD-PE Jacket Material: PVC Connector wiring T568B wire scheme. Fully interoperable and backwards compatible UL Listed 25 Years System Warranty Meet CAT6 Channel Requirements Specified in ANSI/TIA-568-C.2 Applications: 10BASE-T 100BASE-TX Fast Ethernet, 1000BASE-T (IEEE802.3), 100VG-AnyLAN (IEEE802.12); 150 MHz Broadband Video; Voice, T1, ISDN; 155/ 622 Mbps ATM; Power over Ethernet (POE) ELECTRICAL Insulation Resistance DC 300V / 10MΩ MIN Conductance Resistance 1Ω Max. *Cable Tested using H-350 or equivalent cable tester PHYSICAL Plug Assembly Compatible with FCC Part 68 Subpart F Body & Insert PC (Polycarbonate), UL Listed 94V-0 Natural Contact 50 micro- inches Gold Plated Cordage Jacket Dimension Construction OD. 1.5 x 6.0 ± 0.2mm CAT6 32AWG (7/0.08) * 4P + Jacket: PVC B1

44 DME DME PROLINK Copper 24-Port Flat CAT6 Patch Lead, Loaded CAT6, Patch Unshielded, Panel, 1RU PVC, 10cm Part Number D0223-UN0.1PVGY-F Copper Flat Patch Lead, CAT6, Unshielded, 10cm, PVC, Grey B2

45 DME PROLINK Copper Patch Lead, CAT6, Unshielded, LSZH Description DME PROLINK s range of Category 6 Copper Patch Leads are designed for optimal performance and manageability. Our Patch Leads are designed to offer a slim profile specifically for today s high-density environments. Snag-less plug design makes these Patch Cords an excellent choice in environments where moves, adds and changes (MAC s) are frequent. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 Low Smoke Zero Halogen Connector wiring T568B wire scheme. Fully interoperable and backwards compatible UL Listed 25 Years System Warranty B3

46 DME DME PROLINK Copper 24-Port Patch CAT6 Lead, CAT6, Loaded Unshielded, Patch Panel, LSZH1RU TRANSMISSION PERFROMANCE Near End Cross Talk Return Loss Meet all Requirements Specified in ANSI/TIA-568-C.2 Meet all Requirements Specified in ANSI/TIA-568-C.2 ELECTRICAL Continuity Dielectric Withstanding Voltage Change in Resistance <60 mili-ohms, 10VDC 1000 Volts, RMS, 60Hz, 1Min. MECHNICAL Plug Assembly Housing Compatible with FCC Part 68 Subpart F UL Listed 94V-0 Flame-Retardant PC (Polycarbonate) IDC Blades Phosphor Bronze. Contact area of blades is plated with 50 micro- inches of hard gold over 100 micro-inches of Nickel Cordage Jacket Dimension Construction Diameter <0.25 inches CAT6 UTP 24 AWG 7 stranded 4-Pair Copper wire conductor. High Density Polyethylene Insulation Material. FR-PE Low Smoke Zero Halogen Jacket. PHYSICAL Plug Assembly CAT6 Patch Cable Strain Relief Polycarbonate, 94V-0, the contact Area of blades is plated with 50 micro- inches of hard gold over 100 micro-inches of Nickel FR-PE Low Smoke Zero Halogen Jacket BASF TPU Low Smoke Zero Halogen Part Number D0225-UN1LSGY D0224-UN2LSGY D0224-UN3LSGY D0225-UN5LSGY D022x-UN10LSGY D022x-UN20LSGY Copper Patch Lead, CAT6, Unshielded, 1m, LSZH, Grey Copper Patch Lead, CAT6, Unshielded, 2m, LSZH, Grey Copper Patch Lead, CAT6, Unshielded, 3m, LSZH, Grey Copper Patch Lead, CAT6, Unshielded, 5m, LSZH, Grey Copper Patch Lead, CAT6, Unshielded, 10m, LSZH, Grey Copper Patch Lead, CAT6, Unshielded, 20m, LSZH, Grey B4

47 DME PROLINK Copper Patch Lead, CAT6A, Shielded, LSZH Description DME PROLINK s Category 6A Copper Patch Leads are designed for optimal performance and manageability. Our Patch Leads are designed to offer a slim profile specifically for today s high-density environments. Snag-less plug design makes these Patch Leads an excellent choice in environments where moves, adds and changes (MAC s) are frequent.. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 Low Smoke Zero Halogen Stranded cores for enhanced flexibility Performance exceeding Category 6A specifications of 500MHz Snag-less Plug Design Available in various lengths and colors Cable Termination as per T568B wire scheme on both ends. Fully interoperable and backwards compatible UL Listed 25 Years System Warranty B5

48 DME DME PROLINK Copper 24-Port Patch CAT6 Lead, CAT6A, Loaded Shielded, Patch Panel, LSZH 1RU TRANSMISSION PERFROMANCE Meet CAT6A Channel Requirements Specified in ANSI/TIA-568-C.2 ELECTRICAL Electrical Insulation Resistance Dielectric Withstanding Voltage 500MΩ 100 V d.c 1000V DC or AC Peak contact to contact; 1500V DC or AC Peak contact to test panel MECHNICAL Insertion / Extraction Life Tensile Strength 750 Cycles Minimum 20N per Wire PHYSICAL Plug Assembly Housing Compatible with FCC Part 68 Subpart F UL Listed 94V-0 Flame-Retardant PC (Polycarbonate) IDC Blades Phosphor Bronze. Contact area of blades is plated with 50 micro- inches of hard gold over 100 micro-inches of Nickel Shield Cordage Brass alloy plated with 100 micro inch of Nickel Jacket Dimension Construction Diameter <0.25 inches / OD. 6.0 ± 0.2mm CAT6A FTP 26 AWG 7 stranded 4-Pair Copper wire conductor. High Density Polyethylene Insulation Material. Low Smoke Zero Halogen Jacket. Part Number D0233-SH1LSGY D0233-SH2LSGY D0233-SH3LSGY Copper Patch Lead, CAT6A, Shielded, 1m, LSZH, Grey Copper Patch Lead, CAT6A, Shielded, 2m, LSZH, Grey Copper Patch Lead, CAT6A, Shielded, 3m, LSZH, Grey B6

49 DME PROLINK Keystone CAT6 RJ45 Modular Jack, Unshielded, F-Tool Compatible Description DME PROLINK s Keystone Jacks RJ45 are designed to be used with all DME PROLINK compatible products. The jack is designed in such a way that it promotes consistent performance over the life of the system. This includes unique pair separation towers allowing for quicker and easier termination. The connector is configured in a 180 configuration such that the punch field is on the rear of the jack, allowing for rear termination. DME PROLINK System components meet or exceed the requirements for channel and component level performance for the TIA/EIA Category and cul(us) Listed. Compatible with DME PROLINK s Special Termination Tool called F-Tool. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements Snap in style keystone jack; Fire Retardant Grade: UL-94V-0 The termination field is on the rear of the jack for easy access. Can accommodate Conductor diameter in the range mm (AWG 22-24). Connector wiring is universal and has installation color codes for both T568A and T568B wires schemes. 25 Years System Warranty C1

50 DME PROLINK Keystone CAT6 RJ45 Modular Jack, Unshielded, F-Tool Compatible TRANSMISSION PERFROMANCE Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements ELECTRICAL Electrical Insulation Resistance MECHNICAL 500 MΩ 100V DC Dielectric Withstanding Voltage 1000V DC or AC Peak Contact to 60Hz for 1 minute Insertion / Extraction Life IDC Wire Gauge 750 Cycles Minimum 22~24 AWG PHYSICAL Housing High-impact, Flame Retardant Plastic, UL 94V-0 Spring Wire IDC Phosphor Bronze Alloy Plated with 50 micro-inch of gold Phosphor Bronze Alloy with 100 micro-inch 100% Sn Alloy DME PROLINK Keystone Jacks can be terminated with any standard punching tool, but it is recommended to use special DME PROLINK F-Tool. Features & Benefits of DME PROLINK F-TOOL Up to 70% increase in termination speed Termination Force is reduced by70% Sealing and cutting all the wires in one click F-Tool is compatible with CAT3, CAT5e, CAT6 & CAT6A Keystone Jacks Capable of more than 1200 terminations The cutting blades and Jack support are replaceable Locking Handle design Part Number D0313-C6FF Keystone Jack, Unshielded, CAT6, Flush-mount, F-Tool Compatible C2

51 DME PROLINK Keystone CAT6 RJ45 Shuttered Modular Jack, Unshielded, F-Tool Compatible Description DME PROLINK s Shuttered Keystone Jacks RJ45 are designed to be used with all DME PROLINK compatible products. The jack is designed in such a way that it comes with self closing shutter which protects the jack from Dust ingress. This includes unique pair separation towers allowing for quicker and easier termination. The connector is configured in a 180 configuration such that the punch field is on the rear of the jack, allowing for rear termination. DME PROLINK System components meet or exceed the requirements for channel and component level performance for the TIA/EIA Category and cul(us) Listed. Compatible with DME PROLINK s Special Termination Tool called F-Tool. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements Snap in style keystone jack; Fire Retardant Grade: UL-94V-0 Comes with Shutter The termination field is on the rear of the jack for easy access. Can accommodate Conductor diameter in the range mm (AWG 22-24). Connector wiring is universal and has installation color codes for both T568A and T568B wires schemes. 25 Years System Warranty C3

52 DME PROLINK Keystone CAT6 RJ45 Shuttered Modular Jack, Unshielded, F-Tool Compatible TRANSMISSION PERFROMANCE Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements ELECTRICAL Electrical Insulation Resistance 500 MΩ 100V DC Dielectric Withstanding Voltage 1000V DC or AC Peak Contact to 60Hz for 1 minute MECHNICAL Insertion / Extraction Life IDC Wire Gauge 750 Cycles Minimum 22~24 AWG PHYSICAL Housing High-impact, Flame Retardant Plastic, UL 94V-0 Spring Wire IDC Phosphor Bronze Alloy Plated with 50 micro-inch of gold Phosphor Bronze Alloy with 100 micro-inch 100% Sn Alloy DME PROLINK Keystone Jacks can be terminated with any standard punching tool, but it is recommended to use special DME PROLINK F-Tool. Part Number Features & Benefits of DME PROLINK F-TOOL Up to 70% increase in termination speed Termination Force is reduced by70% Sealing and cutting all the wires in one click F-Tool is compatible with CAT3, CAT5e, CAT6 & CAT6A Keystone Jacks Capable of more than 1200 terminations The cutting blades and Jack support are replaceable Locking Handle design D0313-C6FF-S Keystone Jack, Shuttered, Unshielded, CAT6, Flush-mount, F-Tool Compatible C4

53 DME PROLINK Keystone CAT6A RJ45 10G Modular Jack, Shielded, Tool Less Description DME PROLINK s Category 6A Shielded Connectors meet all TIA/EIA Category 6A and ISO/IEC Class Ea performance requirements for internal and Alien Crosstalk parameters up to 500 MHz. The connector provides superior Alien Crosstalk suppression and protects critical data from EMI (electromagnetic interference) and RFI (radio frequency interference). This makes it part of a complete CAT 6A shielded system ideal for use in Healthcare, Manufacturing and other environments where EMI/RFI may be a concern. DME PROLINK System components meet or exceed the requirements for channel and component-level performance for the TIA/EIA Category 6A and is cul(us) Listed. Features & Benefits Complies to TIA/EIA 568-C.2 CAT 6A, ISO/IEC Class EA, IEEE 802.3an 10GBASE-T & FCC Part 68 connecting hardware requirements Mitigates Alien Crosstalk with industry standard density. Shielding provides EMI/RFI protection and data security Connector features robust die-cast housing. Unique design requires no punch-down tool. Connector incorporates a wide angle, hinged design for easy access & termination. Connector wiring is universal and has installation color codes for both T568A and T568B wires schemes. 25 Years System Warranty C5

54 DME PROLINK Keystone CAT6A RJ45 10G Modular Jack, Shielded, Tool Less C6

55 DME PROLINK Keystone CAT6A RJ45 10G Modular Jack, Shielded, Tool Less TRANSMISSION PERFROMANCE Meets all requirements specified in connecting hardware requirements of: ANSI/TIA-568-C.2 Category 6A Draft ISO/IEC Amendment 2, Category 6A Draft ISO/IEC ELECTRICAL Electrical Insulation Resistance MECHNICAL 500 MΩ 100V DC Dielectric Withstanding Voltage 1000V DC or AC Peak Contact to 60Hz for 1 minute, 1500V DC or AC Peak Contact to 60Hz for 1 minute Insertion / Extraction Life IDC Wire Gauge 750 Cycles Minimum 22~24 AWG PHYSICAL Housing Spring Wire IDC Zinc-Alloy Fully Shielded Phosphor Bronze Alloy Plated with 50 micro-inch of gold Phosphor Bronze Alloy with 100 micro-inch 100% Sn Alloy Part Number D0323-C6AFT Keystone Jack, Shielded, CAT6A, Flush-mount, Tool-less C7

56 DME PROLINK 25 Port CAT3 Voice Patch Panel, Tray Type, 1RU Description DME PROLINK s Category 3 Voice patch panels offer high performance and a range of installation options. This patch panel feature user-friendly termination and labeling, plus they can be mounted directly to an EIA standard 19 inch relay rack or cabinet. Features & Benefits Meets requirements of ISO/IEC 11801:2002 and TIA/EIA 568-C High-impact, Flame Retardant Plastic, UL 94V-0 Tray Type Patch Panel 19 Rack Mountable; 1U Rack Space UL Listed 25 Years System Warranty ELECTRICAL Electrical Insulation Resistance MECHNICAL 500 MΩ 100V DC Dielectric Withstanding Voltage 1000V DC or AC Peak Contact to 60Hz for 1 minute, Insertion / Extraction Life IDC Wire Gauge 750 Cycles Minimum 22~26 AWG PHYSICAL Housing High-Impact, Flame Retardant Plastic, UL94V-0 Spring Wire / Contact Blades Phosphor Bronze Alloy Plated with 50 micro-inch of gold Plating Gold Flash & 6u & 15u IDC Phosphor Bronze Alloy with 100 micro-inch 100% Sn Alloy Front Plate SPCC-SD 16G PCB Material FR4 D1

57 DME PROLINK 25 Port CAT3 Voice Patch Panel, Tray Type, 1RU DME PROLINK Voice Patch Panels will have termination field where voice cable can be terminated using 110/66 Punch Down tool. Tool has to be ordered separately. Part Number D UNFLDBK Voice Patch Panel, CAT3, 25 Port, 1RU, Unshielded, Flush, Loaded, Black D2

58 DME PROLINK 24 Port CAT6 Unshielded, Unloaded Patch Panel, 1RU Description DME PROLINK s modular Category 6 Snap-in Fit patch panels offer high performance and a range of installation options. The modular Category 6 panel utilizes the high performing DME PROLINK Snap-in keystone jack. This patch panel feature user-friendly termination, labeling, and cable management, plus they can be mounted directly to an EIA standard 19 inch relay rack or cabinet. Rear cable manager properly guides cables to point of termination. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements High-impact, Flame Retardant Plastic, UL 94V-0 Clear Cover with Labels 19 Rack Mountable; 1U Rack Space ; Removable Rear Cable Manager UL Listed 25 Years System Warranty Snap-in DME PROLINK Keystone Jacks (D0313- C6FF) compatible with this patch panel to be ordered Separately Part Number D UNFULBK Copper Patch Panel, CAT6, 24 Port, 1RU, Unshielded, Flush, Unloaded, Black D3

59 DME PROLINK 24 Port CAT6 Unshielded, Loaded Patch Panel, 1RU Description DME PROLINK s Category 6 Loaded patch panel offer Maximum throughput, reliability and performance for network. It exceeds or meet category 6 connecting hardware specifications for all pair combinations up to 250 MHz and come with third party certification. This patch panel feature user-friendly termination, labeling, and cable management, plus they can be mounted directly to an EIA standard 19 inch relay rack or cabinet. Rear cable manager properly guides cables to point of termination. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements 19 Rack Mountable; 1U Rack Space Can accommodate Conductor diameter in the range mm (AWG 22-24) Connector wiring is universal and has installation color codes for both T568A and T568B wires schemes. Fully interoperable and backwards compatible Removable Rear Cable Manager UL Listed 25 Years System Warranty D4

60 DME DME PROLINK Port CAT6 CAT6 Unshielded, Loaded Patch Loaded Panel, Patch 1RU Panel, 1RU TRANSMISSION PERFROMANCE Meets all requirements specified in ANSI/TIA-568-C.2 CAT6 connecting hardware requirements ELECTRICAL Electrical Insulation Resistance 500 MΩ 100V DC Dielectric Withstanding Voltage 1000V DC or AC Peak Contact to 60Hz for 1 minute MECHNICAL Insertion / Extraction Life IDC Wire Gauge 750 Cycles Minimum 22~24 AWG PHYSICAL Housing High-impact, Flame Retardant Plastic, UL 94V-0 Spring Wire IDC Phosphor Bronze Alloy Plated with 50 micro-inch of gold Phosphor Bronze Alloy with 100 micro-inch 100% Sn Alloy Part Number D UNFLDBK Copper Patch Panel, CAT6, 24 Port, 1RU, Unshielded, Flush, Loaded, Black D5

61 DME PROLINK 24 Port CAT6A Shielded, Unloaded Patch Panel, 1RU Description DME PROLINK s modular Category 6A Snap-in Fit patch panels offer high performance and a range of installation options. The modular Category 6A panel utilizes the high performing DME PROLINK Snap-in keystone jacks. This patch panel feature user-friendly termination, labeling, and cable management, plus they can be mounted directly to an EIA standard 19 inch relay rack or cabinet. Rear cable manager properly guides cables to point of termination. Features & Benefits Meets all requirements specified in ANSI/TIA-568-C.2 Category 6A connecting hardware requirements 19 Rack Mountable; 1U Rack Space Modular panels offer complete flexibility and high port density Expansive cable management and clear labeling Maximum throughput, reliability and performance in your network Flexibility to suit installation requirements Removable Rear Cable Manager UL Listed 25 Years System Warranty D6

62 DME DME PROLINK Port CAT6A Shielded, Loaded Unloaded Patch Panel, Patch 1RU Panel, 1RU Part Number D SHFULBK Copper Patch Panel, CAT6A, 24 Port, 1RU, Shielded, Flush, Unloaded, Black D7

63 DME PROLINK 110 Connectivity System Category 5e / Category 3 Wiring Block Base Wiring block base, 300 pair without Legs Wiring block base, 300 pair with Legs Description DME PROLINK s Category 5e 110 series is a practical choice when setting up Category 5e or CAT3 solution. 110 cabling system consists of blocks, IDCs, patch cords, 110-RJ45 patch cords and patch plugs to complete systems. Features & Benefits UL safety and Category 5e Connecting Hardware performance verified UL94V-0 fire retardant plastic Category 5e and downward compatible 110 IDC designs 1,2,3,4 and 5 pair for voice or data use 25 Years System Warranty 19 CAT 5e Rack mount 110 kit 63 E1

64 DME PROLINK 110 Connectivity System Category 5e / Category 3 Wiring Block Base Wiring block base, 100 pair without Legs Wiring block base, 100 pair with Legs Wiring block base, 50 pair without Legs Wiring block base, 50 pair with Legs Part Number D t P b t Type WL Wall Mount With Legs WNL Wall Mount Without Legs R Rack Mount (19 ) b WOB WB5 WB4 Blocks Without C5 Blocks With C5 Blocks With C4 Blocks Note: If the Wiring Base is used with only C4 blocks then 50-Pair Block capacity changes to 48-Pair 100-Pair Block capacity changes to 96-pair 300-Pair Block capacity changes to 288-Pair p Pair E2

65 DME PROLINK 110 Connectivity System Category 5e / Category 3 IDC Connecting Block 3 pair 110 Snap-on type IDC 4 pair 110 Snap-on type IDC Description DME PROLINK s Category 5e 110 series is a practical choice when setting up Category 5e or CAT3 solution. 110 cabling system consists of blocks, IDCs, patch cords, 110-RJ45 patch cords and patch plugs to complete systems. Features & Benefits UL safety and Category 5e Connecting Hardware performance verified UL94V-0 fire retardant plastic Category 5e and downward compatible 110 IDC designs 1,2,3,4 and 5 pair for voice or data use 25 Years System Warranty Part Number 5 pair 110 Snap-on type IDC D a P C a No. of Pairs E3

66 DME PROLINK CAT6, RJ45 Unshielded Male Plug (8 Pin) Description DME PROLINK s Category 6 Unshielded Plugs meet all TIA/EIA-568-C.2 CAT6 and ISO/IEC Class E performance requirements. This 8 position 8 contact (8P8C) connector is a modular connector commonly used to terminate twisted pair and multi-conductor flat cable.these connectors are commonly used for Ethernet over twisted pair, registered jacks and other telephone applications, RS- 232 serial using the EIA/TIA 561 and Yost standards, and other applications involving unshielded twisted pair and multi conductor flat cable. Features & Benefits It is 8P8C modular plug. 8P8C are commonly used in computer networking and telephone applications, where the plug on each end is an 8P8C modular plug wired according to a TIA/EIA standard. The 8P8C modular connector is also used for RS-232 serial interfaces according to the EIA/TIA-561 standard. 8P8C modular connectors can be also commonly used as a microphone connector for PMR, LMR, and radio transceivers. 25 Years System Warranty Part Number D071-C6RJ45 RJ45 Unshielded Cat-6 Male Plug (8-Pin) 66 F1

67 DME PROLINK Line Jack Units For Terminating Telephone Lines Line Jack 3 Series The Line Jack 3 series range is designed to terminate a single telephone line. They can be either flush or surfacemounted. M3.5 fixing screws are supplied to surface mount to a Plastic back box or to flush mount to a BS4662 back box. Termination is via 3-way BT 238A IDC Connectors. Complete with a fully shuttered BT 601A Jack Socket Outlet. Line Jack 4 Series The Line Jack 4 series range can be either flush or surfacemounted. M3.5 fixing screws are supplied to surface mount to a plastic back box or to flush mount to a BS4662 back box. Termination is via 3-way BT 238A IDC Connectors. Complete with two separate fully shuttered BT 601A Jack Socket Outlets they provide two independent electrically isolated circuits contained in a single housing. Part Number D LJU x / xx x/xx Specification 3/1A Master IDC Socket, with a capacitor, resistor and surge arrestor 3/2A PABX IDC Socket, with a capacitor, but no resistor or surge arrestor 3/3A Secondary (extension) IDC socket without any components fitted. 3/3C Secondary (extension) IDC Socket is as a 3A but with reverse configuration (left latching), designed to accept 430/630 plugs rather than the normal 431/631 plugs. 3/4A Master screw terminal version of LJU3/1A 3/5A PABX screw terminal version of LJU3/2A 3/6A Secondary screw terminal version of LJU3/3A 4/1A 4/3A Dual Master IDC Socket for two separate lines, with capacitors, resistors and surge arrestors Dual Secondary (extension) IDC socket for two separate lines, without any components fitted 4/4A Dual Master screw terminal version of LJU4/1A 4/6A Dual Secondary screw terminal version of LJU4/3A 67 G1

68 DME PROLINK CAT6 RJ Feed Through Coupler Description DME PORLINK s Category Feed Through Coupler is used to extend the length of CAT6 patch cords, or used in standard data wall plates to provide feed through patching. Keystone design allows the coupler to be used as a stand-alone unit, or mounted in a faceplate. Meets EIA/TIA CAT6 specifications. Features & Benefits EIA/TIA Category 6 compliant Keystone design allows multiple connection options Straight-Thru wiring Backwards compatible for use with CAT5e LANs Consists of Gold contacts Part Number D0913-UNC61801K Category 6, RJ Feed Through Coupler 68 G2

69 Our Fiber Optic Cable and Connectivity product range is as deep as Blue Ocean. start EXPLORING

70 Reference: IEC 60793, IEC 60794, ITU-T G 650, G 652D DME DME PROLINK PROLINK Duct Fiber Fiber Fiber Optic Optic Optic Drop Indoor Outdoor Cable Cable, Indoor Cable, MLT, Armored, Single OS2, mode G.652D, MLT (Steel / MRT, KFRP HDPE Wire) Single for FTTx for Mode, FTTx Anti Rodent, G652D, FR-PVC, Black Description DME PROLINK s Multi Loose tube/ Multi Ribbon Tube cable provides excellent optical transmission and physical performance. Loose tube cable is a design that has high tensile strength and flexibility in a compact cable size. Single mode fiber is manufactured by the vapour axial deposition (VAD) process to produce the highest quality glass with excellent geometry, high strength characteristics, and attenuation that approaches theoretical minimum. The single mode fiber is fully compatible with other commercially available single mode fibers and has the zero dispersion wavelength around 1310nm. The main operating wavelength region of the fiber is around 1285nm and 1625nm. Its optical properties are achieved through a germanium doped silica based core with a pure silica cladding. An acrylate protective coating is applied over glass cladding to provide the necessary maximum fiber lifetime. DME PROLINK ensure a continuing level of quality in our cable products through several quality control programs including ISO Also, it ensure product reliability through rigorous qualification testing of each product family. Both initial and periodic qualification testing are performed to assure the cable's performance and durability in the field environments. Cable Design (4 300 Core): The cable core contains single mode fibers in loose tubes and required number of filler which are stranded (S-Z stranding method) around central strength member with water blocking yarn or tape. The interstices in the loose tubes are filled with jelly compound. And then wrapping tape, glass yarn and Flame Retardant PVC sheath apply over the cable core. Cable Design ( Core): The cable core contains consist of parallel arranged 12-primary coated fiber (ribbon fiber) in loose tubes and required number of filler which are stranded (S-Z stranding method) around central strength member with water blocking yarn or tape. The interstices in the loose tubes are filled with jelly compound. And then wrapping tape, corrugated steel tape and flame retardant PVC sheath apply over the cable core H1