ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

Size: px
Start display at page:

Download "ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features"

Transcription

1 Series Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Heater Kit Nomenclature... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagrams Accessories Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Cabinet air leakage less than 2.0% at 1.0 inch H₂O when tested in accordance with ASHRAE standard 193 Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193 AHRI certified; ETL listed Rigid SmartFrame cabinet Horizontal or vertical configuration capabilities 21" depth for easier attic access DecaBDE-free thermoplastic drain pan with secondary drain connections Screw-less sides and back helps to reduce condensation when installed in humid locations Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grain-embossed finish Glue-less cabinet insulation retention Tool-less filter access Field Installed 3 kw 25 kw electric heater kits available * Complete warranty details available from your local dealer or at To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. SS-G 1/18 Supersedes 7/17

2 Nomenclature A 1 R U F 18 B , AA 11,12 Brand Engineering * A Single- piece Major/ Minor Revisions Air Handler * Not used for inventory management Unit Application Refrigerant Charge C Ceiling Mount PSC Motor 4 = R- 410A D Downflow PSC Motor E Multi- Position Variable- Speed Motor Electrical R Multi- Position PSC Motor 1 208/240 V, 1 Phase, 60 Hz S Multi- Position EEM Motor W Wall Mount PSC Motor Cabinet Width B 17½" Cabinet Finish C 21" U Unpainted D 24½" P Painted N Uncased Nominal Capacity 13 SEER 18 1½ Tons 42 3½ Tons Expansion Device 24 2 Tons 48 4 Tons F Flowrater 30 2½ Tons 60 5 Tons T Expansion Valve 36 3 Tons HKS X 03 X A AA ,7 Unit Type Revisions HKS Heat Kit for Engineering Revisions Air Handlers Phase Circuit Breaker A Single Phase 208 V E Three Phase 240 V X No circuit breaker B Single Phase 240 V F Three Phase 208/240 V C Circuit Breaker C Single Phase 208/240 V D Three Phase 208 V G Three Phase 460 V Heating 240 Volts H Special case 208 V * kw kw Cabinet Size (MAX) kw kw wth 150F limit C C Cabinet kw kw with 170F limit D D Cabinet kw kw X All Cabinet Sizes kw *Refer S&R Plate 2 SS-G

3 Product Specifications 25B14* 29B14* 31B14* 37C14* 43C14* 49C14* 37D14* 43D14* 47D14* 49D14* 61D14* Nominal Ratings Cooling (Btu/h) 24,000 25,000 30,000 36,000 42,000 48,000 36,000 42,000 43,000 48,000 60,000 Piston Size Blower Diameter 9½" 9½" 9½" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" /16" Width 6" 6" 6" 8" 8" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" Coil Connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" Coil Drain Connect (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 208/ / / / / / / / / / /230 Min Circuit Ampacity 2.2/ / /2.2 4/4 4/4 4/4 4/4 4/4 4/4 4/4 6/6 Max. Overcurrent Device (Amps) 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 Minimum VAC Maximum VAC Blower Motor Full Load Amps (FLA) Horsepower (HP) ⅓ ⅓ ⅓ ⅓ ⅓ ½ ⅓ ½ ½ ½ ¾ Ship Weight (Lbs.) Note: For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana outdoor unit. Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed. SS-G 3

4 Dimensions 7 3/16" (18.26 cm) 6 1/8" (15.56 cm) 4 1/2" (11.43 cm) K C 2 1/8" (5.40 cm) 5/8" (1.59 cm) B 5/8" (1.59 cm) J 4 5/16" (4.31 cm) 9 1/4" (23.50 cm) 7 1/2" (19.05 cm) 5 1/8" (13.02 cm) 3 1/8" (7.94 cm) 1 3/8" (3.49 cm) 21" (55.88 cm) 11 5/16" (28.73 cm) 1/2" (1.27 cm) 1 5/8" (4.13 cm) 1 5/16" (3.33 cm) 1 3/4" (4.45 cm) HORIZONTAL DRAIN PORT DETAIL 2 11/16" (6.83 cm) 1 3/4" (4.45 cm) 3 1/16" (7.78 cm) A G SEE HORIZONTAL DRAIN PORT DETAIL SUCTION TUBE LIQUID LINE INLET TUBE 2 15/16" (7.46 cm) 3 3/4" (9.53 cm) 1 5/8" (4.13 cm) 10 3/16" (25.88 cm) E D VERTICAL DRAIN PORT DETAIL SEE VERTICAL DRAIN PORT DETAIL H 1 13/16" (4.60 cm) F INLET (FRONT VIEW) 1 13/16" (4.60 cm) 1 " (2.54 cm) 19.5" (49.53 cm) 9/16 (1.43 cm) INLET (RIGHT SIDE VIEW) Model A" B" C" D" E" F" G" H" 25B14* 45 16⅜ 17½ 15¼ 12 14⅛ 9⅛ 11⅞ 29B14* 45 16⅜ 17½ 15¼ 12 14⅛ 9⅛ 12¾ 31B14* 53 7 / 16 16⅜ 17½ / 16 20½ 14⅛ 9⅛ 7⅝ 37C14* 53 7 / 16 19⅞ / 16 18⅝ / / / 16 43C14* 53 7 / 16 19⅞ / 16 18⅝ / / / 16 49C14* 53 7 / 16 19⅞ / 16 18⅝ / / / 16 37D14* 53 7 / / 16 24½ 21½ 18 5 / / 16 12⅝ 6⅞ 43D14* 53 7 / / 16 24½ 21½ 18 5 / / 16 12⅝ 6⅞ 47D14* / 16 24½ 26⅛ 22⅞ 21 3 / 16 12⅝ 25 2 / 16 49D14* 53 7 / / 16 24½ 21½ 18 5 / / 16 12⅝ 6⅞ 61D14* / 16 24½ 26⅛ 22⅞ 21 3 / 16 12⅝ 25 2 / SS-G

5 Airflow Data Model 25B14 29B14 31B14 37C14 43C14 49C14 37D14 43D14 47D14 49D14 61D14 Motor Speed Static Pressure (in w.c) Airflow (CFM) Low Med High Low Med High Low Med High Low Med High Low Med High Low Med High Low Med High Low Med High Low Med High Low Med High Low Med High Notes Airflow data indicated is at 230V without air filter in place. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum design external static pressure. Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations SS-G 5

6 Heat Kit Data Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² 25B14AC 0/0 2.2/2.2 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V Breaker HKSC10XC V HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V Breaker HKSC10XC V B14AC 0/0 2.2/2.2 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V Breaker HKSC10XC V HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V Breaker HKSC10XC V B14AC 0/0 2.2/2.2 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V Breaker HKSC10XC V HKSC15XA V See notes on page SS-G

7 Heat Kit Data (cont.) Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V Breaker HKSC10XC V HKSC15XB V C14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC19CA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC19CB V HKSC15XF V ^ HKSC20XF V ^ D14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V See notes on page 12. SS-G 7

8 Heat Kit Data (cont.) Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC20DA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC20DB V HKSC15XF V ^ HKSC20XF V ^ C14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC19CA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V See notes on page SS-G

9 Heat Kit Data (cont.) Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC19CB V HKSC15XF V ^ HKSC20XF V ^ D14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC20DA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC20DB V HKSC15XF V ^ HKSC20XF V ^ D14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V See notes on page 12. SS-G 9

10 Heat Kit Data (cont.) Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC20DA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC20DB V HKSC15XF V ^ HKSC20XF V ^ C14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC19CA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC19CB V HKSC15XF V ^ HKSC20XF V ^ See notes on page SS-G

11 Heat Kit Data (cont.) Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² 49D14AC 0/0 4/4 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC20DA V HKSC15XF V ^ HKSC20XF V ^ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC20DB V HKSC15XF V ^ HKSC20XF V ^ D14AC 0/0 6/6 15/ HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XA V Breaker HKSC20DA V HKSC15XF V ^ HKSC20XF V ^ HKSC25DA V See notes on page 12. SS-G 11

12 Heat Kit Data (cont.) Heater Kit Model Circuit 1 Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² HKSX05XC V HKSX06XC V No Breaker HKSX08XC V HKSX10XC V HKSC08XC V HKSC10XC V HKSC15XB V Breaker HKSC20DB V HKSC15XF V ^ HKSC20XF V ^ HKSC25DB V ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps --- indicates Not Required Note : The 208 or 240 in the heat kit part number field is for clarification of the nominal voltage for this model. ^ Three Phase 3 Notation is correct as XB because technically the 240V heater kit application can be used here without any issues. Heating kw Correction Factor Supply Voltage Correction Factor Multiply the 240-volt heating capacity by correction factors SS-G

13 Wiring Diagram Air Handler SEE NOTES 2 & 6 GR TERMINAL OCK SHOWN FOR 50HZ MODELS ONLY SR L1 L2 GRND EQUIPMENT GROUND USE COPPER WIRE L1 1 PLF 208/240 VOLTS PLF L2 2 PLF PLM 3 PLM 2 PLM SEE NOTE 4 RC EM HI LO M1 M2 NC COM NO EBTDR SEE NOTE 1 TR IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. GR G R XFMR-R XFMR-C C NC SPEEDUP M1 M2 COPPER POWER SUPPLY (SEE RATING PLATE) EBTDR USE MIN. 75 C FIELD WIRE SEE NOTE 5 K1 K1 NO COM SEE NOTE 3 THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE 3 C (COM) LOW (M2) MEDIUM (M1) HIGH (TR 1) EM RC 3 SPEED V 4 SEE NOTE TR RC EM EBTDR YL COLOR CODE ACK RED YELLOW UE R C EBTDR G 4 24V 5 GR COMPONENT CODE GREEN RPLE OWN EM EVAPORATOR MOTOR RC RUN CAPACITOR SR STRAIN RELIEF R RELAY EBTDR ELECTRONIC OWER TIME DELAY RELAY 6 ITE 5 PLM 4 SEE NOTES 2 & 6 WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE TR PLF TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR PLM FL FUSE LINK TL THERMAL LIMIT GRND GROUND GR NOTES: 1. RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2. SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3. CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, UE FOR MEDIUM, AND ACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR. INACTIVE MOTOR WIRES MUST BE CONNECTED TO "M1 OR M2" ON EBTDR. 4. OWN AND ITE WIRES ARE USED WITH HEAT KITS ONLY. 5. EBTDR HAS A 7 SECOND ON DELAY EN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY EN "G" IS DE-ENERGIZED. 6. LOW VOLTAGE FIELD WIRING TO BE N.E.C CLASS 2 WIRES. 0140A00242-A Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-G 13

14 Wiring Diagram Three-Phase Heater Kit NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. PC TB L1 L2 CIRCUIT 1 1 PH V 1 HTR3 FL TL 2 L1 L2 TR HTR2 3 FL TL L3 L2 L1 CIRCUIT 2 3 PH V GND L1 L2 CC R T1 T2 L3 T3 FL HTR1 TL M1 M2 RS M3 M GR PK SR GR XFMR-R XFMR-C C SPEEDUP EBTDR RC K1 K1 M1 NO COM NC EM NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION PK AR POWER SUPPLY (CIRCUIT 1) L1 L2 RC EM TR VOLT 5 208/240 VOLTS LOW HIGH M1 C NC GR GR EBTDR COM NO EBTDR W W2 W1 PC HKR POWER SUPPLY (CIRCUIT 2) L1 L2 L3 T1 T2 T3 FL HTR3 TL FL HTR2 TL FL HTR1 M2 M 4 M1 M 3 CC RS TL HEATER CONTROL COMPONENT CODE HTR EM EBTDR RS RC TL TR TB CC PC SR FL HEAT ELEMENT EVAPORATOR MOTOR ELEC. OWER TIME DELAY RELAY RELAY/SEQUENCER RUN CAPACITOR THERMAL LIMIT TRANSFORMER TERMINAL OCK CONTACTOR 9-PIN CONNECTOR STRAIN RELIEF FUSE LINK CB CIRCUIT EAKER WIRING CODE HIGH VOLTAGE LOW VOLTAGE Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. L1 COLOR CODE ACK UE OWN GR GREEN OR ORANGE PK PINK RPLE RED ITE YL YELLOW 0140M00273-A 14 SS-G

15 Accessories Expansion Valve Kits for Air Conditioning and Heat Pump Applications Kit Number Description Application Refrigerant Tonnage: Outdoor Unit TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton Downflow Insulation Kit DFK-B DFK-C DFK-D 25B14** 37C14** 37D14** 29B14** 43C14** 43D14** 31B14** 49C14** 47D14** 49D14** 61D14** Filters Chassis Part # Size B ALFH16201E 16.0 x 20.0 C ALFH E 19.5 x 20.0 D ALFH20231E 23.0 x 20.0 SS-G 15

16 Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA SS-G