1. MECHANICAL: 2.ELECTRICAL: Dimension of fan shall be shown in the outline styling drawing attached Dimension Motor Four-pole motor.

Size: px
Start display at page:

Download "1. MECHANICAL: 2.ELECTRICAL: Dimension of fan shall be shown in the outline styling drawing attached Dimension Motor Four-pole motor."

Transcription

1

2 1. MECHANICAL: 1-01 Dimension Dimension of fan shall be shown in the outline styling drawing attached Motor Four-pole motor Frame Plastic material UL V Impeller Plastic material UL V Free drop shock In minute package condition, the fan should withstand each one drop of three faces from 30cm distance height onto 10 mm thickness of wooden board. 2.ELECTRICAL: 2-01 Rated current Rated current shall be measured after 30 minutes continuous rotation at rated voltage Start voltage The voltage that enable to start the fan by sudden switch on Rated Speed 2-04 Input Power 2-05 Lock Current Insulation resistance Dielectric strength Locked motor protection Rated speed shall be measured after 30 minutes continuous rotation at rated voltage. Input power shall be measured after 30 minutes continuous rotation at rated voltage. Locked current shall be measured Within one minute at rotor locked, after 30 minutes continuous rotation at rated voltage in clear air. More than 10M ohm at 500 V.D.C between lead and housing. Measured 5 ma(max) trip current at 700 V.A.C for 3 sec. between lead and housing. Designed to meet UL, CUL and TUV. Page.2

3 3.CHARACTERISTICS: Air Flow 3-01 & Static Pressure 3-02 Noise level The air flow data and static pressures should be determined in accordance with AMCA standard or DIM specification in a double- chamber testing with intake-side measurement. The measurement of noise level is carried out with reference to DIM in an echoic chamber with the microphone positioned 1 M from the air intake. Testing fan shall be hung in clean air. Microphone Test Fan 1M 4.ENVIRONMENTAL: Operating temperature Storage Temperature 4-03 Humidity 4-04 Thermal Shock -10 to 70 (ordinary humidity) -20 to 70 (ordinary humidity) After 96 hrs, 95% RH 40±2 per MIL-STD-202F method 103B, Humidity test, The measured data of insulation resistance & dielectric strength should meet the specification listed in attach. After thermal shock test per MIL-STD-202F method 107D, Condition D, The measured data of insulation resistance & dielectric strength should the specification Page.3

4 5.DATA-SHEET: MODEL JF0515B2H R 5-1. SPECIFICATION: NO. ITEM SPECIFICATION UNIT CONDITION Dimension 50*50*15 mm Bearing Dual ball Rated Voltage 24.0 VDC Operating Voltage 12~27.6 VDC Start Voltage 12 VDC On/off test min Speed 5500 R.P.M ±10%,At rated Speed Input Current 0.10 Amp At rated Voltage Input Power 2.40 Watt At rated Voltage Nominal Current 0.13 Amp At rated Voltage Air Flow CFM At 0 static Pressure of Rated speed Static Pressure inchh 2 O At 0 air flow of rated speed Noise 35.6 dba At rated speed Life Expectancy(L10) 75,000 Hours At 40 Bearing Motor protection Impedance protected Polarity protection It will not damage the fan while reverse input Auto Restart NO Speed Signal output NO Alarm Signal output NO Rotation direction From the label side Clockwise Weight 27 Gram Per each piece Safety Certificate UL, CUL, TUV, CE LEAD WIRE: NO. ITEM CONDITION AWG NO. & Authorize 26 AWG, UL1007(the end of wire with tin as drawing) Color Black Line Length 400±10mm Connector Notes as: Not available Tube No Red Page.4

5 JAMICON (5500RPM) FAN PERFORMANCE CURVES Air Flow (CMM) (M^3/m) Model: JF *50*15mm Pressure (mm-aq) (mm-h2o) Pressure (inch-aq) (inch-h2o) Air Flow (CFM) (ft^3/m) Page.5

6 Page.6

7 A B C D E F G H Date code K A ROT A RY DUAL BALL BEARING 24V 0.13A IM E I E DC L E F C AN T R B R O N U SH L E S S IC R C US C P. R O Date code XX X XX SCALE PRODUCT UNIT mm DESCRIPTION APPEARANCE OF FAN JF0515B2H R DWG. NO: Date Month Year 張冰冰 2013/11/01 DATE REV. Page.7

8 Page.8

9 Page.9

10 Page.10

11 Page.11

12 Page.12