oil standards TRUE NORTH AND ATLANTIS

Size: px
Start display at page:

Download "oil standards TRUE NORTH AND ATLANTIS"

Transcription

1 oil standards TRUE NORTH AND ATLANTIS

2 Accuracy Matters Accurate lab data is critical to sound decision making. Running certified oil standards is the ideal way to ensure the accuracy of your DGA results. Morgan Schaffer produces the world s only commercial gas-in-oil and moisture-in-oil standards. Our oil standards ensure: Credibility: A Certificate of Concentration is provided for each sample for traceability Certificate of Concentration 8300 Saint Patrick, suite 150, Lasalle, Quebec, Canada, H8N 2H1 Tel: Fax: Web: Syringe S/N: Lot No.: Expiry Date: Prepared by: QC Approved: RN RN Component Concentration* (ppm) Component Concentration* (ppm) H 2 O 2 N 2 CH 4 CO (Hydrogen) (Oxygen) (Nitrogen) (Methane) (Carbon Monoxide) CO 2 C 2 H 4 C 2 H 6 C 2 H 2 (Carbon Dioxide) (Ethylene) (Ethane) (Acetylene) (*) Milliliters of gas at 273K and 760 torr per cubic meter of oil. Concentrations are certified by the method of preparation and are verified by laboratory analysis using ASTM D3612 method as well as calibrations using NIST traceable weights. ± defined on a 9 confidence interval for true concentration. Accuracy: Validate the accuracy of your entire analytical process to ensure dependable results Efficiency: Confidence in your data eliminates the need to repeat measurements or analyses Cost savings: Preparing oil standards requires highly-skilled personnel. For most labs, it is too time-consuming and costly to do in-house CIGRÉ and IEC Round Robin Tests Morgan Schaffer s gas-in-oil standards have been used for CIGRÉ and IEC round robin tests and allowed participating labs to improve their accuracy by quantifying otherwise hard-to-detect calibration biases. True North and Atlantis: The world s only commercial oil standards.

3 True North gas-in-oil standards ensure proper calibration of gas extraction and chromatography Guaranteed shelf life: True North: 30 days from syringe filling date True North Long Life: 60 days from syringe filling date Atlantis moisture-in-oil standards allow the validation of the Karl Fischer test method to maintain traceability, precision and accuracy. Guaranteed shelf life: 30 days from syringe filling date Secure Shipment Industry-accepted glass syringes prevent loss of dissolved gases to the atmosphere and contamination by atmospheric components. Individual cardboard packages prevent generation of fault gases from exposure to light. IATA-accepted outer packaging guarantees safe, timely delivery by air, worldwide. Volume Discounts on Blanket Orders Place your annual blanket order for weekly, bi-weekly or monthly shipments of True North and/or Atlantis and enjoy significant discounts! Call or us today to learn more Toll-Free True North and Atlantis: Setting the Standards for Quality Assurance.

4 Accuracy in everything we do. Morgan Schaffer s commitment is not limited to our oil standards. We also ensure excellence in all of our activities: On-time delivery Superior technical support Responsiveness and customer service Repair services Quality assurance across the board Contact us today for more information and delivery scheduling. Head Office Morgan Schaffer USA 8300 Saint Patrick Street Suite 150 LaSalle, Quebec, Canada H8N 2H1 Tel: Fax: Henderson Drive Sharon Hill, Pennsylvania, USA Tel: Accreditations Morgan Schaffer is ISO/IEC 17025:2005 accredited in Canada by the Canadian Standards Council for the tests listed on its scope of accreditation. Morgan Schaffer USA accreditation is forthcoming. Morgan Schaffer is ISO 9001:2008 certified Morgan Schaffer Inc. All rights reserved. The Morgan Schaffer logo is a trademark of Morgan Schaffer Inc.

5 a oil standards TRUE NORTH AND ATLANTIS Technical Specifications Scope of Supply Application Standards profiles QA/QC of DGA methods D3612. IEC and IS 9434 (India) or technically validated dissolved gas-in-oil analysis methods Oil type: Type 1 Naphthenic derivative mineral oil Gases: H 2, CH 4, C 2 H 2, C 2 H 4, C 2 H 6, CO, CO 2, N 2 and O 2 True North nominal concentrations of 10, 100 and 500 ppm for each fault gas True North N 2 and O 2 concentrations are at variable levels from 50,000 to 75,000 ppm and 15,000 to 25,000 ppm respectively Atlantis nominal moisture concentrations are within the ppm range for low concentration standards and ppm for medium concentrations Container Precision and Accuracy Precision Accuracy Conformities Method of preparation Traceability Validation Degree of confidence *Most current version is used. Minimum oil volume of 25 ml per standard 30 ml glass syringe with matched serialized piston and barrel; sealed with peelable silicone 3-way valve, luer-lock and tapered tip or better or 2 ppm, whichever is greater, on entire product concentration range or better or 2 ppm, whichever is greater, on entire product concentration range; determined from theoretical preparation value for each individual component By weight, using NIST traceable gas concentrations and balances in accordance with the principles outlined in ASTM D3612 and IEC standards for the preparation of oil standards True North: ISO 17025:2005 accredited balance calibration and NIST traceable weighted preparation of the gases used in production Atlantis: NIST traceable calibration of the balances used for production True North: Analytical measurements performed according to ASTM D3612* within ISO 17025: 2005 certified QMS Atlantis: Analytical measurements performed according to ASTM D1533* within ISO 17025: 2005 certified QMS Certified values established on a 9 confidence interval with a minimum of 8 degrees of liberty within a Student-t distribution Environment and Safety Usage Ambient temperature of 15 to 30 C Light sensitive: to be used as soon as possible after opening of syringe box Guaranteed shelf life: 30 days from syringe filling date** Environmental: not regulated under WHMIS Storage Storage temperature of -25 to 30 C Safety Material Safety Data Sheets (MSDS) available upon request **Standards with extended shelf life also available - See Options section

6 Shipping Packaging Each True North or Atlantis syringe is packaged in a 31 x 5 x 5 cm / 12.2 x 2.0 x 2.0 in. inner cardboard box 1 to 6 syringes: packaged in IATA-approved 6-pack outer packaging; 32 x 15 x 12 cm / 12.6 x 5.9 x 7.7 in. 7 to 24 syringes: packaged in IATA-approved 24-pack outer packaging; 34 x 30 x 22 cm / 13.4 x 11.8 x 8.7 in. Gross Weight Options Containers Single shipments of more than 24 syringes packaged in variable outer packaging. Contact Morgan Schaffer for exact dimensions, if necessary 1 to 6 syringes: (n* 195 g) g max. 7 to 24 syringes: (n* 195 g) g max. *n = number of syringe samples 50 ml glass syringes available with matched pistons and barrels; sealed with peelable silicone Transformer concentration profile Long Life standards True North standards in Shake Test syringes for use with Myrkos Portable Gas Analyzer available True North Real Life standards feature a concentration profile typical of a North American transformer. Gas levels are adjusted to be near method detection limits to guarantee laboratory performance in measurement during routine operation True North Long Life standards guaranteed for a minimum sheif life of 60 days are available upon request Solubility coefficients Determination of solubility coefficients at both 25 C and 70 C for specific oil types or brands is available on a contractual basis. Warranty and Support True North and Atlantis samples are backed by a 30-day** warranty against loss of stability. Continuing research and improvements may result in specification changes at any time. ** 60-day warranty for True North Long Life standards. Head Office 8300 Saint-Patrick Street, Suite 150 LaSalle, Quebec, Canada H8N 2H1 Tel: Fax: Morgan Schaffer USA 101 Henderson Drive Sharon Hill, Pennsylvania, USA Tel: Accreditation Morgan Schaffer is ISO/IEC 17025:2005 accredited by the Standards Council of Canada for the tests listed on the scope of accreditation. Morgan Schaffer USA accreditation is forthcoming. Morgan Schaffer is certified ISO 9001: Morgan Schaffer Inc. All rights reserved. The MS Morgan Schaffer logo is a trademark of Morgan Schaffer Inc. Oil Standard_Spec_EN2015 rev1