Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

Size: px
Start display at page:

Download "Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-"

Transcription

1

2 Special Marker Pens 4 2 Disposal Bags 4 I 3 Polypropylene Disposal Bags 4 I 3 Polyamide Disposal Bags 4 I 3 Mailing Container 4 I 4 Media Bottles 4 I 4 Hypodermic Needles / Syringes 4 l 5 4 l 6 HandyRack 4 l 6 CryoBox 4 l 8 CryoRack 4 l 9 BetaGuard 4 l 9 Quatro Systems 4 l 0 TempGuard 4 l Floater Rack 4 l PCR Work-Up Rack 4 l 2 Barcode Service 4 l 3 Linear Barcode Labelling of 4 l 3 Linear Barcode Labelling of Cryo.s TM 4 l 3 Datamatrix Codes on Cryo.s TM 4 l 4

3 Special Marker Pens Special Marker Pens Special Marker Pens Water-resistant, quick-drying special marker pens, ideal for labelling of all plastic articles and glassware Available in four colours and two writing thicknesses (super fine and medium) Writing thickness super fine super fine super fine super fine Writing thickness medium medium medium medium 4 2

4 Disposal Bags Disposable Bags Disposal Bags Ideal for the hygienic disposal of contaminated laboratory items Standard disposal bags made of polypropylene foil for sterilisation in the steam autoclave. Oxygen transport rate of 50 µm PP foil (23 C): 2380 cm 3 /(m 2 x 24 h x bar). Water vapour transport rate of 50 µm PP foil (23 C, 85% air humidity):.54 g/(m 2 x 24 h). BAG * polypropylene BAG 2* polypropylene BAG 3* polypropylene polypropylene Width [mm] x length [mm] Foil thickness [mm] Nominal capacity [l] 30 x x x x Suitable for steam autoclaves per case * Supplied with Biohazard label polyamide polyamide polyamide polyamide Width [mm] x length [mm] Foil thickness [mm] Nominal capacity [l] 300 x x x x Suitable for hot-air sterilisers per case

5 Mailing Container / Media Bottles Mailing Container Mailing Container Made of shock-resistant polyethylene (PE) and designed to withstand high mechanical stress Safe transport medium (delivery by post) Available with and without suction lining mailing container, angular suction lining, unprinted with screw cap (loose) optional print for ø [mm] x height [mm] per bag/case 30 x extra charge Media Bottles Media Bottles Made of polyethylene terephthalate (PET) Available in three sizes Sterilised by irradiation With graduation Free of detectable DNase, RNase, human DNA non-pyrogenic noncytotoxic Design Volume [ml] Sterile per bag/case media bottle tetragonal media bottle tetragonal media bottle tetragonal

6 Hypodermic Syringes / Needles Hypodermic Syringes / Needles Hypodermic Syringes / Needles For clinical and research use Individually packed and sterile Hypodermic Syringes SYR SYR 2 SYR 5 SYR 0 Volume [ml] Type per case Volume [ml] SYR SYR SYR SYR 50LS 50 Type per case Hypodermic Needles - Luer fitting N950 N938 N238 N236 Type per case 9g x 2" 00 9g x ¼" 00 2g x ½" 00 23g x 5 /8" 00 Type per case N g x " 00 N332 23g x ¼" 00 N256 25g x 5 /8" 00 N g x "

7 Specialised applications require specialist s - Greiner Bio-One can provide s to suit most applications and in an array of colours for easy identification. Handy position reversible for use with 0.5 and.5ml microtubes Lid needs to be orde separately TR32 NA TR32 FB TR32 FG TR32 FY TR32 FO TR32 FK TRL32 N lid Handy 64 As Handy 32 but with double the capacity Lid needs to be orde separately TR64 N TR64 B TR64 G TR64 Y TR64 O TR64 K TR64 V TR64 R TRL64 N violet lid 4 6

8 Handy 96 As Handy 32 but with triple the capacity Ideal for pipetting to and from 96-well microplates Lid needs to be orde separately TR96 N TR96 B TR96 G TR96 Y TR96 O TR96 K TR96 V TR96 R TRL96 N violet lid Handy 80 General purpose 80 position laboratory Designed for.5ml and 2ml microtubes and skirted 0.5ml microtubes TRC80 N is a container that holds loaded Handy 80 TR80 N TR80 B TR80 G TR80 Y TR80 O TR80 K TR80 V TR80 R TRC80 N violet container with lid 4 7

9 CryoBox 50 & & 50 position cryogenic storage box with hinged lid. TR50 N 50 position TR50 B 50 position TR50 G 50 position TR50 P 50 position TR50 O 50 position TR50 Y 50 position pink TR00 N TR00 B TR00 G TR00 P TR00 O TR00 Y 00 position 00 position 00 position 00 position pink 00 position 00 position CryoBox 8 8 position (9 x 9 format) Separate lid (included) TR8 N TR8 B TR8 K TR8 Y TR8 G TR8 O TR8 P pink 4 8

10 CryoRack position keyed for single handed tube removal BetaGuard 8 & 24 8 & 24 position acrylic beta protection for microtubes (lid included) RS8 C 8 position RS8 B 8 position RS8 G 8 position RS8 R 8 position RS8 Y 8 position RS24 C RS24 B RS24 G RS24 R RS24 Y 24 position 24 position 24 position 24 position 24 position 4 9

11 Quatro Systems Multi format s Ideal for a variety of sizes of containers and tubes Quatro 4 and 8 are capable of supporting vessels up to 30mm in diameter ie: 50ml centrifuge tubes Quatro 2 is capable of supporting vessels up to 25mm in diameter ie: universal containers Quatro 4 TR4 N TR4 FB TR4 FG TR4 FY TR4 FO TR4 FK TR4 FP pink Quatro 8 As Quatro 4 but with double the capacity TR8 N TR8FB TR8 FG TR8 FY TR8 FO TR8 FK TR8 FP pink Quatro 2 As Quatro 4 but with triple the capacity TR2 N TR2 B TR2 G TR2 O TR2 R TR2 V violet 4 0

12 TempGuard Racks Maintains low temperatures for up to 3 hours Options for use at 0 and -20 C CR20 / 0 white CR20 / 20 Temperature 0 C for 3 hours -20 C for 3 hours Floater Rack 24 well for use with microtubes in water baths BR24 B 4

13 PCR Work-Up Racks Designed for use in protocols to create a local workstation for PCR plates, strips and reagents PCR Reagent Rack pink PCR 96-well Rack pink 4 2

14 Barcode Service Linear Barcode Labelling of and Cryo.s TM Barcode Service When large quantities of samples and information are being processed, automated identification offers an efficient means of organisation and management. The application of individual linear barcodes on microplates or Cryo.s TM represents a rapid and easy method to facilitate identification, handling and storage of biological and medical samples. Machine-readable labels with linear barcodes can be implemented in any workflow system, thereby decreasing the risk of manual transcription errors as well as the time and cost involved with sample management. and Cryo.s TM with Linear Barcodes Cell Culture p. I ff. p. 2 I 2 ff. Cryo.s TM p. I 2 ff. Barcoded : Adhesive labels in different sizes Automated processes can be used to attach labels at given specifications on outer perimeter microplate sidewalls The product options include 96, 384 or 536 well microplates made of polypropylene, polystyrene, COC, and other materials Pre-printed barcode labels can also be supplied in rolls Labels are resistant to solvents, temperature fluctuations and smudging. Reading accuracy is ensu Low minimum order requirement! To obtain the separate order forms for microplates and Cryo.s TM with barcodes, please call us on or download them directly from our homepage /technical_information Barcoded Cryo.s TM : Direct print on Cryo.s TM suitable for storage at cryogenic temperatures (-96 C) Print is solvent-resistant to ethanol (up to 70%) and DMSO (up to 50%) Availability of all prevalent barcode symbologies (e.g. Code 28, Code 39, 2/5 interleaved, EAN, HIBC) in various tube sizes ( ml, 2 ml, 4 ml or 5 ml Cryo.s TM with internal or external thread) Screw cap colour can be chosen as desi Low minimum order requirement of one original Cryo.s TM tube box Packaging: ml and 2 ml Cryo.s TM containing 00 items/bag; 4 ml and 5 ml Cryo.s TM containing 50 items/bag Prospective number sequence on bag and box With 00 or 50 coding caps per original box F Barcode ABC F order form microplates with barcode F order form Cryo.s TM with barcode 4 3

15 Barcode Service Datamatrix Codes on Cryo.s TM Recently, the Datamatrix code has been gaining in popularity for use in ting biological and medical reagents and samples. Among the advantages of Datamatrix codes is the nearly infinite scalability of the symbol, thus providing large data capacity within a small footprint. Datamatrix codes can be scanned and decoded independent of their orientation. Moreover, they offer the Reed-Solomon method of error correction which renders high resistance to inaccuracies caused by symbol damage. Greiner Bio-One now offers a wide range of Cryo.s TM equipped with a Datamatrix tag on the tube bottom. The applied ECC200 code is the newest version of Datamatrix that supports advanced error correction algorithms with capability to decipher partially damaged codes. Datamatrix codes are laser-written, thus providing high resistance to mechanical strain and chemicals. Cryo.s TM with Datamatrix Cryo.s TM p. I 2 ff. New Cryo.s TM with Datamatrix ECC200 Datamatrix code with Reed-Solomon algorithm for error correction Readability of partially damaged Datamatrices Laser-written for improved durability and resistance to mechanical strain and chemicals White Datamatrix on background increases contrast and readability Assembly of Datamatrix on tube bottom for accelerated reading Verification of readability during production process; thus excluding incorrect, missing and duplicated codes within an orde range of numbers! The following Cryo.s TM are available with Datamatrix coding: ml and 2 ml tubes with internal thread and starfoot base 2 ml and 4 ml tubes with external thread and starfoot base The order form can be requested by telephone or directly downloaded from our website /cryos. Cryo.s TM with Datamatrix are compatible with numerous automated liquid handling and de-/re-capping systems. For further information on suppliers of compatible accessory equipment please refer to our website /cryos. F order form Cryo.s TM with Datamatrix 4 4