NFPA 1124 (2006 Edition) Compliance List. Temporary Storage

Size: px
Start display at page:

Download "NFPA 1124 (2006 Edition) Compliance List. Temporary Storage"

Transcription

1 NFPA 1124 (2006 Edition) Compliance List Temporary Storage (Multiple Items) Row Labels 7.2 Special Limits for Retail Sales of Consumer Fireworks retail sales including STORAGE shall be in accordance with this code Any building or structure or STORAGE shall comply with NFPA 101 unless modified by this code Retail sales of Display fireworks prohibited at CFRS facility or store Devices prohibited by Child Safety Act of 1966 shall be prohibited at CFRS facility or store Pest control devices shall be prohibited at CFRS facility or store An explosive device used to control animal pests (ATF controlled) Fireworks shall comply with US CPSC and US DOT General Requirements/Distance from Bulk Dispensing and Bulk Storage CFRS areas/storage shall be more than 300 ft from any aboveground bulk storage or bulk dispensing area (flam or comb liquid & gas) General Requirements/Housekeeping fireworks areas/storage kept free of accumulations of debris and rubbish Retail Sales/Source of Ignition cooking equipment of any type prohibited within 20 ft open flame cooking equipment not allowed within 50 ft Stores/Storage Rooms Temporary Storage 1 of 5

2 fireworks storage rooms protected by automatic sprinkler system OR separated from retail area by not less than 1 hour fire barrier fireworks storage room fire barriers shall be protected by self closing fire doors OR fixed fire window with not less than 1 hour rating in accordance with NFPA fireworks storage room fire barrier penetrations shall be protected per NFPA Applicability Storage of consumer fireworks shall comply with this chapter 6.1.2(1) is the storage a permanent building or structure? 6.1.2(2) is the storage a temporary facility? Does the consumer fireworks storage qualify for exempt amounts? 125#/250# or 25% rule Consumer fireworks and pyrotechnic articles defined 6.02 General Requirements for Storage of Consumer Fireworks consumer fireworks shall be tested and certified per regulations of CPSC Shipping containers shall be marked to indicate compliance with Plans site plan for fireworks storage shall include (1) Distances from public ways, buildings, facilities, magazines, motor vehicle fuledispensing stations, retail propane dispensing stations, flammable and combustible liquid aboveground tand storage, and flammable gas and flammable liquified gas bulk aboveground storage and dispensing areas withinn 100 ft of the buiding used to store or handle consumer fireworks (2) vehicle access and parking areas (3)location and type of portable fire extinguishers (4) floor plan and layout of storage and handling to indicate compliance with this chapter (5) Means of egress (6) Construction details Temporary Storage 2 of 5

3 6.3.1 where required, permit shall be obtained to construct, erect or operate any consumer fireworks storage or work building, room, or area where required, plans for consumer fireworks storage shall be submitted to the AHJ with the permit application 6.04 Construction 6.4.1(4) Temporary storage separated by at least 20 feet from any building or structure other than temporary storage 6.05 Fire Protection portable fire extinguisher installed per NFPA Means of Egress if not normally occupied, shall not be required to comply with NFPA exterior exit doors shall open outward doors used as means of egress shall be at least 36 inch wide and kept clear of obstructions dead end aisles shall not exceed 50 ft in length 6.11 Operations receiving, storing, picking from cartons, packing into cartons, packaging into retail packages and shipping shall be permitted in consumer fireworks storage buildings or areas picking, sorting, packaging, packing and similar operations shall be permitted in consumer fireworks storage buildings or areas exterior door and windows shall be locked when building not occupied or attended (1) consumer fireworks shall be stored in DOT approved packaging Temporary Storage 3 of 5

4 6.11.4(2) cartons shall be stacked neatly and in a stable manner (3) consumer fireworks returned to these buildings shall be permitted to be stored temporarily in cartons until repackaging can be performed firearms, unless carried by authorized personnel or law enforcement personnel, shall not be permitted inside consumer fireworks storage or areas within 50 ft of stored consumer fireworks smoking materials, matches, lighters or open flame devices shall not be allowed within 50 ft of any area where fireworks or other pyrotechnic materials are present authorized smoking locations shall be so marked, shall contain designated receptacles for disposal of smoking materials and shall be provided at least one approved fire extinguisher for use on Class A fires 6.12 Housekeeping housekeeping: no loose black powder or other exposed pyrotechnic composition shall be permitted. Upon discovery, shall be removed immediately and disposed of in an approved manner (1) housekeeping: interiors shall be kept clean, dry and free of grit and rubbish (2) housekeeping: tools for cleaning up loose pyrotechnic composition shall not have spark producing metal parts (3) housekeeping: sweepings shall be disposed of in an approved manner area around consumer fireworks storage and work buildings shall be kept clear of brush, dried vegetation, rubbish and similar comestibles for a distance of at least 25 ft 6.14 Trailers, Semitrailers, and Metal Shipping Containers Trailers, semitrailers, or metal shipping containers shall comply with this section Temporary Storage 4 of 5

5 trailers, semitrailers or metal shipping containers that are not normally occupied shall be permitted to be locked during operation where aisle provided, shall not be less than 28 inch in clear width at least 1 pressurized water extinguisher (2 1/2 gallon, 2 A) shall be located within 75 ft panic hardware on exit doors shall not be required trailers, semitrailers or metal shipping containers shall be permitted to be placed side by side with no minimum separation distance and stacked to a maximum height of 2 units Temporary Storage 5 of 5