Shipbuilding & Marine

Size: px
Start display at page:

Download "Shipbuilding & Marine"

Transcription

1 1 Shipbuilding & Marine Many global shipyards and shipping companies rely on STS sensors for the monitoring of water, waste water and fuel tanks - particularly in ballast tank applications. STS is a major supplier in this branch of industry due to the high reliability of its sensors and the ability to manufacture them from titanium.

2 2 Pressure transmitters ATM.1ST Accuracy: ± 0.10 / 0.05 % FS Operating temperature: C Output signal: 0 5 / 0 10 V DC, 4 20 ma Total Error Band: ± 0.30 %FS (0 70 C) High precision pressure sensor over the whole temperature range Very short response times Intrinsically safe pressure transmitters ATM.1ST/Ex Accuracy: ± 0.10 / 0.05 % FS Operating temperature: C Total Error Band: ± 0.30 %FS (0 70 C) High precision pressure sensor over the whole temperature range Very short response times

3 Submersible level transmitters ATM.1ST/N 3 Accuracy: ± 0.10 % FS Total Error Band: ± 0.30 %FS (-5 50 C) Output signal: 0 5 / 0 10 V DC, 4 20 ma High precision pressure sensor over the whole temperature range Intrinsically safe submersible level transmitters ATM.1ST/N/Ex Accuracy: ± 0.10 % FS Total Error Band: ± 0.30 %FS (-5 50 C) High precision pressure sensor over the whole temperature range

4 4 Pressure transmitters ATM.ECO Accuracy: ± 0.25 % FS Operating temperature: C Process temperature: C Output signal: 0 5 / 0 10 V DC, 4 20 ma Total Error Band: ± 0.70 %FS (0 70 C) Very short response times Intrinsically safe pressure transmitters ATM.ECO/Ex Accuracy: ± 0.25 % FS Operating temperature: C Process temperature: C Total Error Band: ± 0.70 %FS (0 70 C) Very short response times

5 Submersible level transmitters ATM.ECO/N 5 Accuracy: ± 0.25 % FS Total Error Band: ± 0.70 %FS (-5 50 C) Output signal: 0 5 / 0 10 V DC, 4 20 ma Intrinsically safe submersible level transmitters ATM.ECO/N/Ex Accuracy: ± 0.25 % FS Total Error Band: ± 0.70 %FS (-5 50 C)

6 6 Pressure transmitters ATM Accuracy: ± 0.50 / 0.25 / 0.10 % FS Operating temperature: C Output signal: 0 5 / 0 10 V DC, 0 20 / 4 20 ma connections) Manual readjustment of 'span' and 'offset' possible Available with lightning protection Short response times Intrinsically safe pressure transmitters ATM/Ex Accuracy: ± 0.50 / 0.25 / 0.10 % FS Operating temperature: C Manual readjustment of 'span' and 'offset' possible Available including lightning protection Short response times

7 Submersible level transmitters ATM/N 7 Accuracy: ± 0.50 / 0.25 / 0.10 % FS Output signal: 0 5 / 0 10 V DC, 0 20 / 4 20 ma Feature: Optional surge (lightning) protection Recalibration possible Available with lightning protection Intrinsically safe submersible level transmitters ATM/N/Ex Accuracy: ± 0.50 / 0.25 / 0.10 % FS Feature: Optional surge (lightning) protection

8 8 Programmable intrinsically safe pressure transmitters PTM/Ex Adjustable 1:4 of the nominal range within -5% to +105% Accuracy: ± 0.25 / 0.10 % FS Operating temperature: C Feature: Recalibration with software possible Scalable pressure ranges and output signals Available with surge (lightning) protection Flexibly applicable pressure sensor Modular sensor structure (Any process and electrical connections Can be combined) Programmable intrinsically submersible level transmitters PTM/N/Ex Accuracy: ± 0.25 / 0.10 % FS Adjustable 1:4 of the nominal range within -5% to +105% Feature: Recalibration with software possible Scalable pressure ranges and output signals Flexibly applicable pressure sensor

9 HEADQUARTERS STS Sensor Technik Sirnach AG SUBSIDIARIES STS France STS Germany GmbH STS Italia s.r.l. STS Great Britain Ltd. AGENTS STS Sensor Technik Sirnach AG is supported by an excellent international distribution network. Represented by Specification may change without notice. global.sensor.excellence