15
16
17
18
19 Baffled Openings at Chain Link Fencing: Design shall consist of two end-posts set 4 feet apart, and a 10 foot wide chain-link fence panel equal in height as the adjacent fence. Chain link fence panel shall terminate at two line posts set 3 feet inside the fence line. Design shall comply with applicable Codes and M-DCPS Design Standards. November, 2017 Baffled Openings at Chain Link Fencing A02-01 Issued Design Criteria Appendix A M- DCPS
20 November, 2017 Elementary - Basketball/Volleyball Hardcourts - Combined Markings A02-02 Issued Design Criteria Appendix A M- DCPS
21 November, 2017 Elementary - Volleyball Hardcourts - Sleeves Locations A02-03 Issued Design Criteria Appendix A M- DCPS
22 November, 2017 K-8 Center - Basketball/Volleyball Hardcourts - Combined Markings A02-04 Issued Design Criteria Appendix A M- DCPS
23 November, 2017 K-8 Center - Volleyball Hardcourts - Sleeves Locations A02-05 Issued Design Criteria Appendix A M- DCPS
24 November, 2017 Middle & Senior HS - Basketball/Volleyball Hardcourts - Combined Markings A02-06 Issued Design Criteria Appendix A M- DCPS
25 November, 2017 Middle and Senior HS - Volleyball Hardcourt - Sleeves Locations A02-07 Issued Design Criteria Appendix A M- DCPS
26 November, 2017 Volleyball Standards and Ground Sleeves Details A02-08 Issued Design Criteria - Appendix M- DCPS
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66 March, 2018 Dedication Plaque Text Layout A10-01 Issued Design Criteria M- DCPS
67 NOTE: Information reflected on the sample Dedication Plaque noted above, is indicated for layout purposes only. March, 2018 Dedication Plaque Sample Layout A10-02 Issued Design Criteria M- DCPS
68
69
70
71 April, 2016 Type 4 Computer Lab Layout A13-04 Issued Design Criteria M- DCPS
72 April, 2016 Satellite Wiring Closet A13-05 Issued Design Criteria M- DCPS
73 April, 2016 Main Telephone Communications Room A13-06 Issued Design Criteria M- DCPS
74 April, 2016 Senior High School - ITV System - Distribution Room Front View A13-07 Issued Design Criteria M- DCPS
75 April, 2016 Senior High School - ITV System - Distribution Room Top View A13-08 Issued Design Criteria M- DCPS
76 April, 2016 Senior High School - ITV System - Distribution Room Wiring A13-09 Issued Design Criteria M- DCPS
77 April, 2016 Senior High School - ITV System - Control Room - Front View A13-10 Issued Design Criteria M- DCPS
78 April, 2016 Senior High School - ITV System - Control Room - Top View A13-11 Issued Design Criteria M- DCPS
79 April, 2016 Senior High School - ITV System - Production Studio A13-12 Issued Design Criteria M- DCPS
80 April, 2016 Senior High School - ITV System - Editing Rooms #1 & #2 A13-13 Issued Design Criteria M- DCPS
81 April, 2016 Senior High School - ITV System - Facility Distribution Raceways A13-14 Issued Design Criteria M- DCPS
82 February, 2017 Middle School - ITV System - CCTV Rm - Front View A13-15 Issued Design Criteria M- DCPS
83 February, 2017 Middle School - ITV System - CCTV Rm - Top View A13-16 Issued Design Criteria M- DCPS
84 February, 2017 Middle School - ITV System - CCTV Room Wiring Distribution A13-17 Issued Design Criteria M- DCPS
85 February, 2017 Middle School - ITV System Facility Distribution Raceways A13-18 Issued Design Criteria M- DCPS
86 February, 2017 Elementary Schools & K-8 Centers - ITV System - CCTV Rm - Front View A13-19 Issued Design Criteria M- DCPS
87 February, 2017 Elementary Schools & K-8 Ctrs. - ITV System - CCTV Rm. - Top View A13-20 Issued Design Criteria M- DCPS
88 February, 2017 Elementary School & K-8 Ctrs - ITV System - CCTV Rm Wiring Distribution A13-21 Issued Design Criteria M- DCPS
89 February, 2017 Elementary Schools & K-8 Ctrs - ITV System - Facility Distribution Raceways A13-22 Issued Design Criteria M- DCPS
90 February, 2017 ITV System - Parapet Mounted Mast Antenna A13-23 Issued Design Criteria M- DCPS
91 NOTE: Coordinate with the latest M-DCPS Design Criteria and Master Specifications requirements. February, 2017 Security Alarm Systems A13-24 Issued Design Criteria M- DCPS
92 CAFETORIUM at ELEMENTARY SCHOOLS and MIDDLE LEARNING CENTERS (MLC), and LANGUAGE ARTS LAB (LITTLE THEATER) at MIDDLE SCHOOLS NOTE: COORDINATE ACTUAL REQUIREMENTS WITH M-DCPS PROJECT SPECIFIC EDUCATIONAL SPECIFICATIONS, AND THE LATEST M-DCPS DESIGN CRITERIA AND MASTER SPECIFICATIONS. February, 2017 Type 1 - Sound Reinforcement System A13-25 Issued Design Criteria M- DCPS
93 CAFETORIUM at MIDDLE SCHOOLS and K-8 CENTERS, and LANGUAGE ARTS LAB (LITTLE THEATER) at SENIOR HIGH SCHOOLS NOTE: COORDINATE ACTUAL REQUIREMENTS WITH M-DCPS PROJECT SPECIFIC EDUCATIONAL SPECIFICATIONS, AND THE LATEST M-DCPS DESIGN CRITERIA AND MASTER SPECIFICATIONS. February, 2017 Type 2 - Sound Reinforcement System A13-26 Issued Design Criteria M- DCPS
94 SENIOR HIGH SCHOOL CAFETORIUM NOTE: COORDINATE ACTUAL REQUIREMENTS WITH M-DCPS PROJECT SPECIFIC EDUCATIONAL SPECIFICATIONS, AND THE LATEST M-DCPS DESIGN CRITERIA AND MASTER SPECIFICATIONS. February, 2017 Type 3 - Sound Reinforcement System A13-27 Issued Design Criteria M- DCPS
95 NOTE: COORDINATE ACTUAL REQUIREMENTS WITH M-DCPS PROJECT SPECIFIC EDUCATIONAL SPECIFICATIONS, AND THE LATEST M-DCPS DESIGN CRITERIA AND MASTER SPECIFICATIONS. February, 2017 Type 4 - Sound Reinforcement System A13-28 Issued Design Criteria M- DCPS
96 Guidelines for EMS Graphical Interface The EMS Graphical Interface shall consist of a group of interactive color graphics that record, report, and respond to real-time commands and information pertaining to the Energy Management System (EMS). These graphics shall include but not be limited to, a Log-on portal, the School Energy Management Center Portal and additional sub-graphics displaying information on the Plant Operations, Energy Usage, the Chiller Plant, all AHUs, all VAV Boxes, all Exhaust Fans, Lights, Override Panel, and Schedules. NOTES/DEFINITIONS: 1. Each graphics page shall contain, in an appropriate location, the full name of the Facility that it serves. 2. All Facility spaces shall be labeled using the Florida Inventory of School House (F.I.S.H.) numbering scheme designated by M-DCPS. 3. All temperature readings shall be indicated in F. 4. All pop-up window and all equipment and components reflected on each graphic window shall be properly identified. 4. The sample graphics enclosed in these Guidelines are to be used for general references only. These graphics may not contain all the information required by these Guidelines. The Contractor shall ensure that the graphics packaged developed for the Work accurately reflects ALL the requirements stated in these Guidelines. GRAPHIC REQUIREMENTS: Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-29 Issued Design Criteria M- DCPS
97 Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-30 Issued Design Criteria M- DCPS
98 WINDOW No. 1 : LOG-ON WINDOW - Provide a password protected log-on screen to access the EMS Energy Portal. WINDOW No. 2 : SCHOOL ENERGY MANAGEMENT CENTER (EMS) PORTAL - Graphics shall display the following: A. Facility Information: 1. Picture of the School. 2. School name. 3. Location number. 4. Phone number. 5. Address. B. Provide a visual/audible Warning signal triggered by one of the following events: Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-31 Issued Design Criteria M- DCPS
99 1. EMS set to EHPA mode. 2. Equipment set on Manual By-Pass mode. 3. Equipment set on a 24/7 Time-of-Day Schedule mode. 4. Chillers failure to run as scheduled. C. Individual pop-up display windows showing the following real-time information: 1. TIME in hh:mm AM/PM; and DATE in month/dd/yyyy. 2. HVAC Mode (ON/OFF). 3. Outdoor temperature. 4. Indoor temperature (at Administration area). 5. Energy Usage graph [Energy (KW Demand) vs. Time (Months)]. 6. Year-to-Date (YTD) Consumption in KWh/Month. 7. Demand Budget in KW/Month. 8. Actual Demand in KW. 9. To-Date Projection in %. 10. A Happy Face icon reflecting a comparison of the Demand Budget vs. the Actual Demand. A happy face will mean that the Actual Demand is below the Demand Budget, and a sad face will mean that the Actual Demand exceeds the Demand Budget. The Happy Face icon shall also be a hot-link to the Energy Usage window. Place a note under the Happy Face icon stating Click here for Energy Usage. D. Individually labeled buttons to access the following graphic windows: 1. Plant Operations. 2. Schedules. 3. Energy Usage - accessed by means of the interactive happy/sad face button. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-32 Issued Design Criteria M- DCPS
100 WINDOW No. 3 : PLANT OPERATIONS - Graphics shall display the following: A. In a table format provide the following information: 1. One (1) interactive button for each AHU and Chiller unit, each labeled with a unique tag comprising of the F.I.S.H room number and building name where the unit is located (e.g., AHU 1127 / Bldg. B - Media Ctr.; AHU 2013 / Bldg. C - 1 st Fl., or Chiller 1 / Chiller Plant). Each interactive button shall provide direct access to the AHU or Chiller graphics applicable to that equipment. 2. For each AHU and Chiller, provide a cluster of five (5) side-by-side pop-up displays reporting the following real-time information: a. Schedule Mode: Occupied / Unoccupied. b. Fan or Chiller Command ON / OFF. c. Fan or Chiller Status ON / OFF. d. Supply Air/Water Temperature. e. Return Air/Water Temperature. 3. For each AHU that contains VAV boxes in their system, provide one (1) interactive button labeled VAVs to access a Floor Plan Layout containing all VAV boxes serving that AHU. See the Floor Plan Layout section of these Guidelines for additional details and requirements. B. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Chiller Plant. 3. Exhaust Fans. 4. Lighting. 5. Override Panel. 6. Schedules. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-33 Issued Design Criteria M- DCPS
101 KWH KWH WINDOW No. 4 : ENERGY USAGE - Graphics shall display the following: Daily KWH Consumption /9 8/11 8/13 8/15 8/17 8/19 8/21 8/23 8/25 8/27 8/29 8/31 9/2 9/4 9/ Monthly KWH Consumption Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec A. Individual pop-up displays windows showing the following real-time information: 1. Instant Demand showing the following: a. KW Demand. b. Monthly KWh Consumption. c. Daily KWh Consumption. B. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. 3. Schedules. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-34 Issued Design Criteria M- DCPS
102 WINDOW No. 5 : CHILLER PLANT - Graphics shall display the following: A. Labeled graphics for each of the following systems and equipment: 1. Chillers. 2. Chilled Water Pumps. 3. Condenser Water Pumps. 4. Primary Water Pumps (If used). 5. Cooling Towers. 6. Chill water and Condenser Water Piping layout. 7. Motorized Valves. 8. Variable Frequency Drives (VFDs). B. Individual pop-up display windows showing the following real-time information: 1. Chilled Water Supply Temperature. 2. Chilled Water Return Temperature. 3. Condenser Water Supply Temperature. 4. Common Chilled Water Supply Temperature. 5. Common Chilled Water Return Temperature. 6. Common Condenser Water Supply Temperature. 7. Chillers Command Enable / Disable. 8. Chillers Status ON / OFF. 9. Chillers Capacity (Showing a range of 0-100%). 10. Pumps Command ON/OFF. 11. Pumps Status ON / OFF. 12. Cooling Towers Command Enable / Disable. 13. Cooling Towers Status ON / OFF. 14. Cooling Towers Speed. 15. Button to Enable / Disable the Chiller Plant. 16. Button for each Chiller to Start / Stop. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-35 Issued Design Criteria M- DCPS
103 C. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. 3. Schedules. WINDOW No. 6 : AIR HANDLING UNITS (AHU) and PRE-COOLING COILS - Graphics shall display the following: A. Each AHU labeled with a unique number comprising of the F.I.S.H room number and building name where the unit is located, and containing the following systems and equipment: 1. Coils, fans / blowers, dampers, valves, filters, heaters, water pipes, and supply / return ducts. B. Individual pop-up display windows showing the following real-time information: 1. Fan Command Occupied / Unoccupied (DO). 2. Fan Status (DI). 3. VFD speed (AI). 4. Supply Air Set Point (Variable Volume AHU) (AO). 5. Return Air Set Point (Constant Volume AHU) (AO). 6. Static Pressure Set Point (AO). 7. Heating Set Point (Constant Volume AHU) (AO). 8. Outside Air Set point (AO). 9. CO2 Set Point (AO). 10. Outside Air Set Point (AO). 11. Supply Air temperature (AI). 12. Return Air Temperature (AI). 13. Static Pressure (AI). 14. Outside Air CFM (AI). 15. CO2 PPM (AI). 16. Heat status ON/OFF. 17. Chill Water Valve Command (Showing range of 0-100%). 18. Chill Water Valve Position (Showing range of 0-100%). Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-36 Issued Design Criteria M- DCPS
104 19. Outside Air Damper Command (Showing range of 0-100%). 20. Outside Air Damper position (Showing range of 0-100%). 21. Filter status Clean/Dirty. C. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. 3. Schedules. WINDOW No. 7 : FLOOR PLAN LAYOUT - Graphics shall display the following: A. The Floor Plan graphics shall reflect the general footprint layout for each building and room, and shall contain the following information for each: 1. Individual Building Name/Numbers. 2. Individual Floor Numbers. 3. Individual F.I.S.H Room Number for each space. 4. Individual VAV boxes, each numbered with the F.I.S.H number of the space that it serves, and providing a direct link to their respective VAV box graphics page. B. Individual pop-up display windows showing the following real-time information: 1. Room temperature. 2. Duct System Layout with labeled buttons to access each VAV box. C. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. 3. Schedules. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-37 Issued Design Criteria M- DCPS
105 WINDOW No. 8 : VARIABLE AIR VOLUME (VAV) - Graphics shall display the following: A. Each VAV unit labeled with a unique number comprising of the F.I.S.H room number that the unit serves. For each VAV provide pop-up windows displaying the following realtime information: 1. Supply Air Set Point (AO). 2. Heating Set Point (AO). 3. Air Flow Set Point (AO). 4. Command Occupied / Unoccupied. 5. Damper Command (Showing range of 0-100%). 6. Heating Command (DO). 7. Cooling Demand (Showing range of 0-100%). 8. Supply Air Temperature (AI). 9. Space Temperature (AI). 10. Air Flow (AI). B. Individually labeled button to access the following graphic window: 1. Floor Plan of the area being served by the VAV box. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-38 Issued Design Criteria M- DCPS
106 WINDOW No. 9 : EXHAUST FANS - Graphics shall display the following: A. Each Exhaust Fan labeled with a uniquely number comprising of the F.I.S.H room number and building name of the space that it serves. For each Exhaust Fan provide pop-up display windows displaying the following: 1. Command ON/ OFF. 2. Status of each Exhaust Fan, (green for ON; red for OFF). B. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. 3. Schedules. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-39 Issued Design Criteria M- DCPS
107 WINDOW No. 10 : LIGHTING - Graphics shall display the following: A. The following Items and information shall be display on the Lighting Page: 1. Electrical Panel Name. 2. Electrical Panel Location. 3. Circuit Number. 4. Name of the Area that it serves. 5. EMS Controller Name and location. 6. Command ON / OFF. 7. Lighting Status. B. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. 3. Schedules. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-40 Issued Design Criteria M- DCPS
108 WINDOW No. 11 : OVERRIDE PANEL - Graphics shall display the following: A. The graphical interfaces for the Override Panel shall display the following information: 1. Labeled Zones. 2. One (1) labeled button per zone, to place zone in Override mode. 3. One (1) LED light per zone to indicate when the zone is in Override mode. 4. A display window for each zone, showing the remaining time in Override mode. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-41 Issued Design Criteria M- DCPS
109 B. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operation. 3. Schedules. 4. Override Panel Instructions. This window will provide a brief description on how to operate the Override Panel. On the bottom of the Override Panel Instructions page, provide a labeled button to Go Back to Override Panel. C. On the bottom half of the Override Panel graphics, provide a Facility Floor Plan layout showing each Building, each Zone and each AHU within in each Zone. WINDOW No. 12 : SCHEDULES - Graphics shall display the following: A. Graphics shall include individually labeled buttons to access for Schedules for each of the following zones: 1. Administration / Student services. 2. Food Services / Dining Room. 3. Auditorium. 4. Gymnasium. 5. Media Center. 6. Instructional Spaces. 7. Interior Corridor Lights. 8. Parking Lot Lights. 9. Exterior Lights (Comprising of all exterior lights except Parking Lot lights). B. Individually labeled buttons to access the following graphic windows: 1. School Energy Management Center Portal. 2. Plant Operations. C. Provide a minimum of one (1) Zone or Schedule per building, and no more than five (5) AHUs per Zone or Schedule. Prior to implementation of any Time of Day Schedules, the Contractor shall provide M-DCPS District Inspections, Operations, Energy Management DIOEM (Energy Management System Staff) a copy of all proposed schedules for their review and final acceptance. Ferbruary, 2017 Guidelines for Energy Management System Graphical Interface A13-42 Issued Design Criteria M- DCPS
110
111
112
113
Condenser Water Heat Recovery"
PLEASE MUTE CELL PHONES Condenser Water Heat Recovery" Julian de Bullet ASHRAE Distinguished Lecturer Director of Industry Relations McQuay International 703-395-5054 1 What Is Sustainability? sustainable
More informationExisting Building Cx: Processes & Results A Cultural Journey. Barry Abramson Senior Vice President Servidyne
Existing Building Cx: Processes & Results A Cultural Journey Barry Abramson Senior Vice President Servidyne AIA Quality Assurance Learning Objectives 1. Define the key steps in the process of retrocommissioning
More informationMarysville School District Resource Conservation Program. John Bingham Marysville S.D. Ray Burton Snohomish Co. P.U.D.
Marysville School District Resource Conservation Program John Bingham Marysville S.D. Ray Burton Snohomish Co. P.U.D. Tools Resource Conservation Program Utility budget Utility tracking Benchmarking Load
More informationThe Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma
LEED Green Building Certification The purpose of the LEED Green Building Rating is to provide a national standard that aims to improve environmental, health and economic performance of buildings using
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. Provide a building temperature control/building automation system (BAS) for the space temperature control and monitoring of defined environmental conditions. General system
More informationOptimizing Energy Use in a HealthCare Setting. Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning
Optimizing Energy Use in a HealthCare Setting Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning AIA Quality Assurance The Building Commissioning Association is a Registered
More informationExample LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal
Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal The following documentation provides an example submittal for the LEED-NC v2.1 Energy & Atmosphere Credit 1 (EAc1). This sample EAc1 submittal
More informationLow Cost Building Automation System for Small- and Medium- Sized Commercial Buildings
Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings Srinivas Katipamula, Ph.D. Staff Scientist, Pacific Northwest National Laboratory Other TAG Members: Irfan Rehmanji
More informationThe Mirenda Center for Sports, Spirituality, and Character Development
prepared by: Zachary Heilman MECHANICAL OPTION prepared for: James Freihaut, PhD Technical Report 3: (Mechanical Systems Existing Conditions Evaluation) Due Date: November 29, 2010 The Mirenda Center for
More informationRobert E. McMains Date Robert E. McMains Date
DESIGN AND CONSTRUCTION STANDARDS Title: Section 230923 Direct-Digital Control System for HVAC & Mechanical Author: Author: Date Active Version Distribution: Date Approved By: Approved By: Robert E. McMains
More informationGround-Coupled Heat Pump And Energy Storage
Ground-Coupled Heat Pump And Energy Storage By Ed Lohrenz, Member ASHRAE; and Sergio Almeida, P.Eng., Member ASHRAE Ground-coupled heat pump (GCHP) systems consume less purchased energy than an HVAC system
More informationEnergy Reduction Strategy Through 2020
Through 2020 Revised: August 2017 Executive Summary Auburn University is a land, sea and space grant university established in 1856. The university consists of 11,629,000 square feet on 1,840 acres and
More informationENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN
ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN 2014 2019 CONTENTS EXECUTIVE SUMMARY... 3 1. CENTENNIAL COLLEGE - DISTRIBUTION OF ENERGY CONSUMPTION IN 2012... 4 1.1. Overview of Centennial College
More informationLow-Hanging Fruit Simple Steps Toward Energy Effective Building Operations
Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations Roger Ebbage Northwest Water / Energy Education Institute Lane Community College May 7-9 Enzian Inn - Leavenworth, Washington
More informationCity of Fort Collins Building Automation Systems Enhances Savings and Commissioning Efficiency Works Training
City of Fort Collins Building Automation Systems Enhances Savings and Commissioning Efficiency Works Training November 18, 2015 Agenda Commissioning Monitoring Based Commissioning Building Tune up Case
More informationBanyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL
SECTION 01815 - HVAC COMMISSIONING REQUIREMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division
More informationRetro-Commissioning for Existing Facilities
Retro-Commissioning for Existing Facilities Tom Meyer Director, Technical Programs National Environmental Balancing Bureau 8575 Grovemont Circle Gaithersburg, Maryland 20877 (301) 977-3698 www.nebb.org
More informationOPTIMIZATION OF ICE THERMAL STORAGE SYSTEM DESIGN FOR HVAC SYSTEMS
OPTIMIZATION OF ICE THERMAL STORAGE SYSTEM DESIGN FOR HVAC SYSTEMS Nabil Nassif, Ph.D. P.E. Christopher Hall Dante' Freeland Assistant professor Graduate Student Graduate Student Department of Civil, Architectural,
More informationIndiana University Glick Eye Institute. LEED Measurement & Verification Plan
Indiana University Glick Eye Institute LEED Measurement & Verification Plan April 10, 2012 1 Table of Contents General Introduction... 3 Facility Description... 4 M&V Objectives... 4 M&V Approach/Option...
More informationAdvantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure
Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure Guanghua Wei, P.E. Malcolm Verdict, C.E.M Joseph T. Martinez Energy Systems Laboratory, 3581 TAMU Texas A&M University
More informationENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.
Report To: Mr. John Smith Smith Printing Company ENERGY AUDIT 123 Main Street Mississauga, Ontario January 1, 2009 120 Carlton Street, Suite 212 Toronto, Ontario M5A 4K2 Tel 416-964-3246 Toll Free 1-866-964-3246
More informationEnergy modeling in IDA ICE according to ASHRAE , app. G
Energy modeling in IDA ICE according to ASHRAE 90.1-2007, app. G About this document This document is a user s guide for a relatively experienced IDA ICE operator for using the 90.1 add-in and for performing
More informationCONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING
CONDENSING TEMPERATURE CONTROL THROUGH ENERGY MANAGEMENT SYSTEM SIMULATON FOR A LARGE OFFICE BUILDING Young-Hoon Kwak 1, Dong-Seok Kong 1, Se-Hwan Cheon 1, Ro-Yeul Kwak 2, and Jung-Ho Huh 3 1 Department
More informationUnion College Combined Cooling, Heat and Power Project
Union College Combined Cooling, Heat and Power Project Presented by: Mark Donovan, PE Union College, Assistant Director of Utilities Aaron Bolhous, PEng CHA, Project Engineer Agenda Introduction to Union
More informationa comparative study of secondary glycol and direct expansion refrigeration systems
a comparative study of secondary glycol and direct expansion refrigeration systems Second Nature Medium-Temperature secondary systems have been widely applied in commercial refrigeration since their introduction
More informationTexas Hospital. Central Plant Redesign. Central Utility Plant SECOND PLACE HEALTH CARE FACILITIES, EXISTING 2013 ASHRAE TECHNOLOGY AWARD CASE STUDIES
This article was published in ASHRAE Journal, January 2014. Copyright 2014 ASHRAE. Posted at www. ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission
More informationUse of Building Automation Systems for (Retro)Commissioning
Center for Energy and Environment Use of Building Automation Systems for (Retro)Commissioning Neal Ray, Center for Energy and Environment Gustav Brändström, Center for Energy and Environment January 17,
More informationItalcementi Center for Research and Innovation
Italcementi Center for Research and Innovation Bergamo, Italy LEED-NC v2.1 EAc1 A. Project Narrative (Viridian) analyzed the energy use of the proposed Italcementi Center for Research and Innovation located
More informationRetrocommissioning (RCx)
Retrocommissioning (RCx) Facilities & Services - Engineering Services Saving the planet, two buildings at a time. Mr. Karl Helmink Mr. Damon McFall Creating a Sustainable Campus What is Retrocommissioning
More informationA/E Design Deliverable Checklist
A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic
More informationElectricity Survey and Analysis
Electricity Survey and Analysis Prepared for: Centre in the Square Inc. 101 Queen St. North Kitchener, ON N2H 6P7 Prepared by: Stantec Consulting Ltd. 49 Frederick St. Kitchener, ON N2H 6M7 September 14,
More informationModeling and analyzing solar cooling systems in Polysun
Modeling and analyzing solar cooling systems in Polysun Seyed H. Rezaei (seyed.rezaei@velasolaris.com) 1 Andreas Witzig (andreas.witzig@velasolaris.com) 1 Michael Pfeiffer (michael.pfeiffer@velasolaris.com)
More informationElement Z General Design Requirements Existing Facilities Information
Anderson Central 100B, PART 1 - INTRODUCTION 1.01 OVERVIEW A. This Section provides general information for building systems and components. B. Refer to the Owner s Design Guideline Elements A though G
More informationUnderf loor For Schools
The following article was published in ASHRAE Journal, May 2008. Copyright 2008 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes
More informationApplication of a cooling tower model for optimizing energy use
Advances in Fluid Mechanics X 305 Application of a cooling tower model for optimizing energy use G. C. O Mary & D. F. Dyer Department of Mechanical Engineering, Auburn University, USA Abstract The overall
More informationDesignTools Software Energy Analyzer User Manual
DesignTools Software Energy Analyzer User Manual Table of Contents Introduction...1 Installing Energy Analyzer...3 Getting Started...4 General...4 Project Details (Energy Analyzer Wizard Application)...5
More informationASHRAE 62.2: What s New in 2016
ASHRAE 62.2: What s New in 2016 Rick Karg 2016 Residential Energy Dynamics, LLC What We Will Talk About Overview of mechanics of 62.2-2016. Logic behind the Standard. Sizing local ventilation (exhaust-only).
More informationEhsan Soltani. Date of Birth: 1 Sep, 1980 Nationality: Iranian Marital Status: Married Mobile :(+98)
Ehsan Soltani Date of Birth: 1 Sep, 1980 Nationality: Iranian Marital Status: Married E-mail: ehsan.soltani@gmail.com Mobile :(+98) - 912-1501764 CAREER BRIEF: Having over 15 Years Work Experience in Iran
More informationA/E Design Deliverable Checklist
A/E Design Deliverable Checklist Design deliverables for the Design Development phase shall include all items listed in the Design Development column as well as those all items listed in the Schematic
More informationRhode Island Commercial Codes FAQs
Rhode Island Commercial Codes FAQs When does the new code go into effect? The new suite of building codes (including the new state energy conservation code, SBC-8) was adopted on July 1, 2013. A brief
More informationPRESENTATION BY: Sean P. Murray Energy/Facility Use Manager St. Lucie County Public Schools. Art Munns Senior Project Engineer OCI Associates, Inc.
PRESENTATION BY: Sean P. Murray Energy/Facility Use Manager St. Lucie County Public Schools Jason Smith, PE, LEED AP BD+C, CEM Principal / Dir. of Mech. Engineering OCI Associates, Inc. Art Munns Senior
More informationNo Cost/Low Cost Energy
No Cost/Low Cost Energy Saving Strategies Randall D. Manteufel University of Texas at San Antonio Energy Efficiency in Local Government andschool Districts in the Border Region No Cost/Low Cost Relatively
More informationChilled Beams. The new system of choice?
Chilled Beams The new system of choice? Presented By: Kevin M. Pope P.E. Jason Leffingwell Hammel Green And Abrahamson, Inc. and Ken Bauer, P.E., LEED AP Butters-Fetting Co., Inc. History of Chilled Beams
More informationAdministration Division Public Works Department Anchorage: Performance. Value. Results.
Administration Division Anchorage: Performance. Value. Results. Mission Provide administrative, budgetary, fiscal, and personnel support to ensure departmental compliance with Municipal policies and procedures,
More informationHotels: Water and Energy
Hotels: Water and Energy Agenda 01 Introduction 05 Hotel System Options 02 Company Overview 06 Hotel Energy Conservation 03 Hotel Energy & Water Use 07 Hotel Project Examples 04 Design Philosophy Introduction
More informationDESIGN BASIS FOR AIR CONDITIONING AND VENTILATION SYSTEM FOR SUBSTATION AND CONTROL BUILDING HINDUSTAN PETROLEUM CORPORATION LTD.
CONDITIONING AND VENTILATION FOR SUBSTATION AND CONTROL BUILDING HINDUSTAN PETROLEUM CORPORATION LTD. VISAKH REFINERY DHT PROJECT TEIL JOB NO.: 6261 DOCUMENT NO.: 6261-HVAC-PKG-300 TEIL SPECIFICATION NO.:---
More informationYWCA 1503 S. Denver Tulsa, Oklahoma 5/18/2010 Performed By
Energy Audit for YWCA 1503 S. Denver Tulsa, Oklahoma 5/18/2010 Performed By 220 E. 8th Street Tulsa, Oklahoma 74119 918-582.0229 Fax: 918.599.0665 www.craftontullsparks.com Table of Contents Cover Page...
More informationCFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH
CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000
More informationAHU Models Using Whole Building Cooling and Heating Energy Consumption Data
Calibrating AHU Models Using Whole Building Cooling and Heating Energy Consumption Data Mingsheng Liu, Ph.D., P. E. ; Guanghua Wei; and D. E. Claridge, Ph.D., P. E. Energy Systems Laboratory Texas A&k?
More informationApplication of Advanced Energy Technologies
GLOBALCON 2002 Philadelphia, Pennsylvania March 27, 2002 Application of Advanced Energy Technologies Michael K. West, Ph.D., P.E. Building Systems Scientist Advantek Consulting, Inc. www.advantekinc.com
More informationSolar Energy Technologies
1 Solar Energy Technologies ME 430 Queen s University The Solar Energy Resource Varies over day and year, (i.e., intermittent) Generally non-dispatchable Ottawa average for year ~4 kwh/m 2 per day e.g.,
More informationPLUMMER ELEMENTARY SCHOOL
INITIAL YEAR BUILT 1959 BUILDING AREA 69,400 SF CURRENT PROGRAM CAPACITY 481 ENROLLMENT 2008 228 WARD 7 PROPOSED PROGRAM CAPACITY 325 Site Plan PLUMMER - 1 PROPOSED PROGRAM PROFILE GRADE CONFIGURATION
More informationIECC Commercial Significant Changes Summary Tier I
2009-2015 IECC Commercial Significant Changes Summary Tier I The first change is in the layout of the book. Instead of having Chapters 1-3 that applied to all projects and then having Chapter 4 Residential
More informationMcCarran International Airport Terminal 3
McCarran International Airport Terminal 3 The Pennsylvania State University Architectural Engineering Senior Thesis Final Report Evaluation of Underfloor Air Distribution and Displacement Ventilation Systems
More informationAnalysis 2: Alternative Thermal Window Design
Analysis 2: Alternative Thermal Window Design (8.1) Problem Statement: In the first analysis, the cost and environmental impacts of the addition of solar PV panels to the roof of GrandView was determined.
More information35% reduction in water use below code maximum 83% 88% 49% reduction in lighting power density 12%
Science Center Cabot Library Project LEED CI v4.0 1 Oxford Street, Cambridge, ma LEED Certified Project Profile December 2017 The Science Center Cabot Library project was comprised of renovating the entry,
More informationThesis Proposal. Park. Findlay 12/10/2010. Connor Blood
1 Park Place Corporate Center One Mechanical Senior Thesis Project Thesis Proposal Park Place Corporate Center One Findlay Township,, PA 12/10/2010 Proposal Connor Blood 2 Park Place Corporate Center One
More informationDIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT
PROJECT REPORT DIRECTIONAL-BORE GROUND SOURCE HEAT PUMP FIELD REPORT Rio Mondego, California August 214 WESTERN COOLING EFFICIENCY CENTER PREPARED FOR: Bruce Baccei Project Manager Sacramento Municipal
More informationAchieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics
Achieving acoustical standards in the classroom Study of HVAC systems and classroom acoustics Trane believes the facts and suggestions presented here to be accurate. However, final design and application
More informationVentilation. Demand-controlled ventilation (DCV) Demand-Controlled. With ASHRAE Standard Based
CO Demand-Controlled 2 -Based Ventilation With ASHRAE Standard 62.1 Though not as straightforward as it once was, remains a practical way to reduce costs Editor s note: Following is an update of the November
More informationBuilding X Retrocommissioning Final Report
Building X Retrocommissioning Final Report A study done by Portland Energy Conservation, Inc. (PECI) And Partner IMPORTANT NOTICE: This sample document is provided for instructional purposes only. CCC
More informationNew Specialty Crops for California
New Specialty Crops for California Mark Gaskell, Farm Advisor UC Cooperative Extension - Santa Maria UC Statewide Small Farm Program California Offers A Special Mix Diverse growing environments Large,
More informationA CASE STUDY IN ACTUAL BUILDING PERFORMANCE AND ENERGY MODELING WITH REAL WEATHER DATA
A CASE STUDY IN ACTUAL BUILDING PERFORMANCE AND ENERGY MODELING WITH REAL WEATHER DATA Cherag Mehta 1, and Alan S. Fung 2 1 Engineer-in-Training APEGA, MBSc and LEED GA 2 Mechanical and Industrial Engineering,
More informationCHP Case Studies. Midwest CHP Application Center (MAC) .org (312) University of Illinois at Chicago Energy Resources Center UIC
CHP Case Studies Midwest CHP Application Center (MAC) www.chpcentermw.org.org (312)413-5448 University of Illinois at Chicago Energy Resources Center CHP Case Studies Elgin Community College Presbyterian
More informationMBCx: The Next Wave of Energy Savings in Utility Incentive Programs
AABC Commissioning Group AIA Provider Number 50111116 MBCx: The Next Wave of Energy Savings in Utility Incentive Programs Course Number: CXENERGY1716 Walid Guerfali, ComEd Ben Talbot, DLR Group Ruairi
More informationGreat Ocean Rd Ice Creamery
Great Ocean Rd Ice Creamery BCA Section J - JV3 Compliance Report Revision: 01 Job No: 2171 Date: 7 July 2015 ADP Consulting Pty Ltd Level 10, 10 Queens Rd, Melbourne Vic 3004 www.adpconsulting.com.au
More informationHOLDER CONSTRUCTION COMPANY Superintendents Weekly Activity Report #92 Douthit Hills Student Community, Clemson University Project Joe Jett
SAFETY» Total Man Hours Worked This Week: 19935» Total Man Hours on Project: 689727» Crafts On Project This Week: 24» OSHA Recordable Rate: 0 November 13, 2016 Page 1 CURRENT CONSTRUCTION ACTIVITIES East
More informationEnergy Savers: Air-Source Heat Pumps
1 of 5 4/25/2009 8:55 AM U.S. Department of Energy - Energy Efficiency and Renewable Energy Energy Savers Air-Source Heat Pumps An air-source heat pump can provide efficient heating and cooling for your
More informationRecommissioning Energy Savings Persistence
Recommissioning Energy Savings Persistence Martin Selch and James Bradford, PE, PhD Nexant, Inc. Synopsis Utilities, administrators, or turnkey providers in many areas around the country offer recommissioning
More informationLECKIE ELEMENTARY SCHOOL
INITIAL YEAR BUILT 1970 BUILDING AREA 65,000 SF CURRENT PROGRAM CAPACITY 471 ENROLLMENT 2008 321 WARD 8 PROPOSED PROGRAM CAPACITY 400 Site Plan LECKIE - 1 PROPOSED PROGRAM PROFILE GRADE CONFIGURATION PK-5
More informationNEWMOA June 30, Fran Boucher LEED AP, Certified Energy Manager Senior Energy Engineer
NEWMOA June 30, 2009 Fran Boucher LEED AP, Certified Energy Manager Senior Energy Engineer Utility Incentives MA, RI, NH, VT, ME, CT, Long Island NY, Gas in NYC New construction and gas in Upstate NY.
More informationAchieving a cost optimal balance between heat supply efficiency and moderation of demand
Achieving a cost optimal balance between heat supply efficiency and moderation of demand Dr. Christian Friebe Thüga Aktiengesellschaft COGEN Europe, 25th of February 560 cities and towns, 100 companies
More informationABSTRACT I. INTRODUCTION II. METHODS AND MATERIAL
2017 IJSRSET Volume 3 Issue 2 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Chiller and AHU Design for A commercial Usage S M Azfar Hashmi, Mirza Muneer Baig,
More informationComprehensive Energy Audit For Kongiganak Health Clinic
Comprehensive Energy Audit For Kongiganak Health Clinic Prepared For Native Village of Kongiganak September 15, 2011 Prepared By: ANTHC DEHE Energy Projects Group Anchorage, Alaska 99508 1 Table of Contents
More informationHow to Reduce Energy Use in Your Labs by Up to 50%
How to Reduce Energy Use in Your Labs by Up to 50% Illinois Chapter of ASHRAE April 11, 2017 Dan Doyle, Chairman Grumman/Butkus Associates 1 Course Description Labs have high exhaust requirements and large
More informationGround Coupled Heat Pump Systems a Key for a Sustainable Development of Heating and Cooling Buildings
Ground Coupled Heat Pump Systems a Key for a Sustainable Development of Heating and Cooling Buildings GABRIEL V. BENDEA*, MARCELA F. PRADA**, CODRUTA C. BENDEA*, CALIN D.SECUI* Department of Energy Engineering
More informationInformation Delivery Manual (IDM)
Piping Engineering - Confluence http://idm.buildingsmart.no/confluence/display/idm/piping+engineering?decorator=printable 1 af 2 11-09-2011 19:21 Information Delivery Manual (IDM) Added by Jeffrey Wix,
More informationHeating, ventilation and air conditioning zone controls
Technology information leaflet ECA762 Heating, ventilation and air conditioning zone controls A guide to equipment eligible for Enhanced Capital Allowances Contents Introduction 01 Background 01 Setting
More informationIntroduction of the latest Technology of Energy Conservation
Introduction of the latest Technology of Energy Conservation --- To blue chip companies due to effective energy utilization --- September 15, 2015 Fuji Electric Co., Ltd. 1 Trends and prospects of the
More informationEnergy Report - February 2008
Energy Report - February 28 Glossary Ampere - The unit of measurement of electrical current produced in a circuit by 1 volt acting through a resistance of 1 Ohm. British thermal unit (Btu) - The quantity
More informationMSC Guidelines for Review of Ventilation System Plans
K. B. FERRIE, CDR, Chief, Hull Division Purpose: This Plan Review Guideline (PRG) explains the requirements for seeking plan approval of ventilation systems from the Marine Safety Center (MSC) for most
More informationA GUIDE TO REACH SYSTEM RELIABILITY. Commercial HVAC Buyers Guide
A GUIDE TO REACH SYSTEM RELIABILITY Commercial HVAC Buyers Guide How to confidently select your HVAC contractor, compare options and quotes, and enjoy system reliability. If you are reading this document,
More informationLEED Commissioning and Actual Energy Use. John Kokko, P.Eng. LEED A.P. Vice President Enermodal Engineering
LEED Commissioning and Actual Energy Use John Kokko, P.Eng. LEED A.P. Vice President Enermodal Engineering AIA Quality Assurance Learning Objectives 1. Why Best Practice and Fundamental Commissioning are
More informationB. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationDESIGN & CONSTRUCTION PHASE COMMISSIONING PLAN TEMPLATE
DESIGN & CONSTRUCTION PHASE COMMISSIONING PLAN TEMPLATE Based upon B3 Minnesota Sustainable Building Guidelines VERSION 2.1 Notes to the reader have been added to this document within numerous text boxes
More informationCOURSE LISTING. Courses Listed. with Business Intelligence (BI) Crystal Reports. 26 December 2017 (18:02 GMT)
with Business Intelligence (BI) Crystal Reports Courses Listed BOC345 - SAP Crystal Reports 2011: Optimizing Report Data Processing BOC320 - SAP Crystal Reports: - BOCE10 - SAP Crystal Reports for Enterprise:
More informationTransforming your Historical Metrics to a Futuristic State
Transforming your Historical Metrics to a Futuristic State Forrest W. Breyfogle III CEO, Smarter Solutions, Inc. SmarterSolutions.com +1 512.918.0280 Forrest@SmarterSolutions.com Copyright 1992 2014. All
More informationEstablishing a Baseline, Energy Audits and Energy Star s Portfolio Manager
Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager Glenn Barnes Environmental Finance Center University of North Carolina at Chapel Hill 919-962-2789 glennbarnes@sog.unc.edu Energy
More informationModeling for LEED. Refer to Additional LEED credits on page 6 90 for a list of credits TRACE 700 may help to achieve.
Modeling for LEED USGBC s Leadership in Energy and Environmental Design (LEED) program updates its products to closely align with the latest industry standards. LEED version 3, the most recent version
More informationPROJECT INFORMATION REPORT INFORMATION. Date: February 25, Owner s Rep: Alrich Lynch. 123 Project Address Drive, Savannah GA 31404
LDG Consulting Providing Orientation, Direction, and Execution to the Design, Construction, and Real Estate Industries REPORT INFORMATION Date: February 25, 2015 Owner s Rep: Alrich Lynch Electronic Copy:
More informationCase Study for Fortune 500 Telecom: Retrofitting Pneumatic Controls for Energy Efficiency
Case Study for Fortune 500 Telecom: Retrofitting Pneumatic Controls for Energy Efficiency Summary Major Fortune 500 Telecom Company Estimated 40% the corporate building portfolio still use pneumatic thermostats
More informationEnhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti. 12 May 2011
Enhance Facility Energy Management at Naval Expeditionary Base Camp Lemonnier, Djibouti 12 May 2011 Report Documentation Page Form Approved OMB No. 0704-0188 Public reporting burden for the collection
More informationPowering Michigan Agriculture with Renewable Energy
Powering Michigan Agriculture with Renewable Energy ENERGY AUDIT & RENEWABLE ENERGY ASSESSMENT ENERGY PYRAMID MICHIGAN STATE UNIVERSITY MI Agricultural Energy Use Significant MI Dairy Farms Energy Use
More informationEnergy-Efficient Passive House using thermal mass to achieve high thermal comfort
Energy-Efficient Passive House using thermal mass to achieve high thermal comfort Loa Andersson Managing Director RLI Byggdata AB rli@termodeck.com Alexander Engström Technical Director RLI Byggdata AB
More informationCompliance Certificate
REScheck Software Version 4.6.4 Compliance Certificate Project RESIDENCE Energy Code: 2009 IECC Location: Perkasie, Pennsylvania Construction Type: Single-family Project Type: New Construction Conditioned
More informationNASA Langley Research Center Administration Office Building One Hampton, VA. Project Proposal. Introduction to Proposed Design Alternatives Revision 1
NASA Langley Research Center Administration Office Building One Hampton, VA Project Proposal Introduction to Proposed Design Alternatives Revision 1 Valerie Miller Mechanical Dr. Freihaut Revised 01/16/2015
More informationNovember 28, Dear Mr. Bechtold:
4000 Hollywood Boulevard Seventh Floor, North Tower Hollywood, Florida 33021 (954) 987-0066 Fax: (954) 987-2949 November 28, 2012 Wastewater Compliance and Enforcement Section FLORIDA DEPARTMENT OF ENVIRONMENTAL
More information5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationFundamentals of Test & Balance for Engineers, Cx & Energy Providers Course Number: CXENERGY1619
AABC Commissioning Group AIA Provider Number 50111116 Fundamentals of Test & Balance for Engineers, Cx & Energy Providers Course Number: CXENERGY1619 Jim Hall, PE, TBE, CxA Systems Management & Balancing,
More informationLEED v4 Building Design and Construction Quiz #8 EQ
LEED v4 Building Design and Construction Quiz #8 EQ 1. Which of these is considered an unoccupied space? [Choose three] A. School classroom B. Mechanical room C. Meeting room D. Locker room E. Restroom
More information