3867 en / f. Alternators. LSA Pole Electrical and mechanical data

Size: px
Start display at page:

Download "3867 en / f. Alternators. LSA Pole Electrical and mechanical data"

Transcription

1 3867 en / f kva - Hz kva - 6 Hz Alternators LSA Pole Electrical and mechanical data

2 SPECIALLY ADAPTED FOR APPLICATIONS The LSA 49.1 alternator is designed to be suitable for typical generator applications, such as: backup, standard production, cogeneration, marine applications, rental, telecommunications, etc. COMPLIANT WITH INTERNATIONAL STANDARDS The LSA 49.1 alternator conforms to the main international standards and regulations: IEC 634, NEMA MG 1.22, ISO 828, CSA, CSA/UL, marine regulations, etc. It can be integrated into a CE marked generator. The LSA 49.1 is designed, manufactured and marketed in an ISO 91 environment. TOP OF THE RANGE ELECTRICAL PERFORMANCE - Class H insulation. - Standard 6-wire re-connectable winding, 2/3 pitch, type no Voltage range Hz : 38V - 4V - 41V and 22V - 23V - 24V, - Voltage range 6 Hz : 38V - 416V - 44V - 48V and 22 V - 24 V. - High efficiency and motor starting capacity. - Other voltages are possible with optional adapted windings : - Hz : 44 V (no. 7), V (no. 9), 6 V (no. 22 or 23), 69 V (no. 1 or 2) - 6 Hz : 38 V and 416 V (no. 8), 6 V (no. 9). - Total harmonic content < 4 %. - R 791 interference suppression conforming to standard EN 11 group 1 class B standard for European zone (CE marking). EXCITATION AND REGULATION SYSTEM SUITED TO THE APPLICATION Excitation system Regulation options Voltage regulator AREP PMG Current transformer for paralleling Mains paralleling R phase sensing R 731 R 734 mains paralleling unbalanced Remote voltage potentiometer R 4 Std Option D 1 (digital) Optional Optional Included Included see factory Voltage regulator accuracy +/-.%. : adaptation possible. PROTECTION SYSTEM SUITED TO THE ENVIRONMENT - The LSA 49.1 is IP Standard winding protection for clean environments with relative humidity %, including indoor marine environments. Options: Filters on air inlet and air outlet (IP 44). Winding protections for harsh environments and relative humidity greater than %. Space heaters. Thermal protection for winding. REINFORCED MECHANICAL STRUCTURE USING FINITE ELEMENT MODELLING - Standard direction of rotation : clockwise when looking at the drive end view (engine side). - Compact and rigid assembly to better withstand generator vibrations. - Steel frame. - Cast iron flanges and shields. - Twin-bearing and single-bearing versions designed to be suitable for engines on the market. - Half-key balancing. - Regreasable bearings. - Standard direction of rotation : clockwise when looking at the drive end view (for anti-clockwise, derate the machine by %). ACCESSIBLE TERMINAL BOX PROPORTIONED FOR OPTIONAL EQUIPMENT - Easy access to the voltage regulator and to the connections. - Possible clusion of accessories for paralleling, protection and measurement. - Connection bar for reconnecting voltage. Copyright 24 : MOTEURS LEROY-SOMER Products and materials shown in this catalogue may, at any time, be modified in order to follow the latest technological developments, improve the design or change conditions of utilization. Their description cannot, in any case, engage LEROY-SOMER liability. The values indicated are typical values. 2

3 Common data Insulation class H Excitation system A R E P or PMG Winding pitch 2/3 ( N 6S) A.V.R. model R 4 Terminals 6 Voltage regulation (*) ±, % Drip proof IP 23 Sustained short-circuit current 3% (3 IN) : 1s Altitude 1 m Total harmonic (* *) TGH / THC at no load < 4 % - on load < 4% Overspeed 22 min -1 Waveform : NEMA = TIF - (* *) < Air flow except L11 1 m 3 /s (Hz) / 1,2 (6Hz) Wave form : C.E.I. = FHT - (* *) < 2 % Air flow L m 3 /s (Hz) / 1,4 m 3 /s (6Hz) (*) Steady state duty. (**) Total harmonic content line to line, at no load or full rated linear and balanced load. Ratings Hz - 1 R.P.M. kva / kw - Power factor =,8 Duty T C Continuous duty / 4 C Continuous duty / 4 C Stand-by / 4 C Stand-by / 27 C Class / T K H / 12 K F / 1 K H / 1 K H / 163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 4V 41V 38V 4V 41V 38V 4V 41V 38V 4V 41V Δ 22V 23V 24V 22V 23V 24V 22V 23V 24V 22V 23V 24V 49.1 S4 kva kw M6 kva kw M7 kva kw L9 kva kw L1 kva kw L11 kva kw New Ratings 6 Hz - 18 R.P.M. kva / kw - PF =,8 Duty / T C Continuous duty / 4 C Stand-by / 4 C Stand-by / 27 C Class / T K H / 12 K F / 1 K H / 1 K H / 163 K Phase 3 ph. 3 ph. 3 ph. 3 ph. Y 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V 38V 416V 44V 48V Δ 22V 24V 22V 24V 22V 24V 22V 24V 49.1 S4 kva kw M6 kva kw M7 kva kw L9 kva kw L1 kva kw L11 kva kw New 3

4 Efficiencies Hz - P.F. : 1 / P.F. :,8 LSA 49.1 S4 P.F. : P.F. :, kva LSA 49.1 M6.3 P.F. : P.F. :, kva LSA 49.1 L P.F. : P.F. :, kva LSA 49.1 L1.7 P.F. : P.F. :, kva LSA 49.1 M7.2 P.F. : P.F. :, LSA 49.1 L11 P.F. : P.F. :, kVA kva Reactances (%). Time constants (ms) - Class H / 4 V S4 M6 M7 L9 L1 L11 Kcc Short-circuit ratio,38,43,39,43,41.37 Xd Direct axis synchro.reactance unsaturated Xq Quadra. axis synchr.reactance unsaturated T do Open circuit time constant X d Direct axis transient reactance saturated 17, 14,7 16,2 14,4 14, T d Short-Circuit transient time constant X"d Direct axis subtransient reactance saturated 14 11,7 12,9 11, 11, T"d Subtransient time constant X"q Quadra. axis subtransient reactance saturated 16,3 13,1 14, 12, Xo Zero sequence reactance unsaturated,9,7,8,8,9.9 X2 Negative sequence reactance saturated 1,2 12, 13,8 12,1 12, 13.7 Ta Armature time constant Other data - Class H / 4 V io (A) No load excitation current,9,9,,9,9,9.8 ic (A) Full load excitation current 3,6 3,2 3, 3,3 3,4 3.2 uc (V) Full load excitation voltage ms Recovery time (DU = 2 % trans.) kva Motor start. (DU = 2% sust.) or (DU = % trans.) % Transient dip (rated step load) - PF :,8 LAG 13,3 1,9 11,7 1, W No load losses W Heat rejection New New 4

5 Transient voltage variation 4V - Hz 2 % Load application ( AREP or PMG system) S 4 1 M 6 M 7 % Voltage dip 1 L 9 L 1 L kva kva at,8 power factor Load rejection (AREP or PMG system) 2 % S 4 M 6 M 7 % Voltage rise 1 1 L 9 L 1 L kva kva at,8 power factor Motor starting (AREP or PMG system) 3% S 4 M 6 M 7 L 9 L 1 L 11 2 % Voltage dip % kva 88.7 Locked rotor 1) For a starting P.F. other than,6, the starting kva must be multiplied by K = Sine Ø /,8 Calculation example for a different P.F. : Starter motor kva calculated at.4 P.F. = 7 kva Sin Ø,4 =,916 K = 1,14 kva corrected = 88,7 kva Voltage dip corresponding to L11 = 12 %. 2) For voltages other than 4V (Y), 23V ( ) at Hz, then kva must be multiplied by (4/U)2 or (23/U)2.

6 Efficiencies 6 Hz - P.F. : 1 / P.F. :,8 LSA Pole % LSA 49.1 S4.9 P.F. : P.F. :, kva % LSA 49.1 M6.2 P.F. : P.F. :, kva LSA 49.1 M7.2 P.F. : P.F. :, kva LSA 49.1 L9.6 P.F. : P.F. :,8.1, kva LSA 49.1 L1.6 P.F. : P.F. :, , kva LSA 49.1 L11.4 P.F. : P.F. :, , kVA Reactances (%). Time constants (ms) - Class H / 48 V S4 M6 M7 L9 L1 L11 Kcc Short-circuit ratio,38,43,39,43,41.36 Xd Direct axis synchro.reactance unsaturated Xq Quadra. axis synchr.reactance unsaturated T do Open circuit time constant X d Direct axis transient reactance saturated 17, 14,7 16,2 14,4 14,9 17 T d Short circuit transient time constant X"d Direct axis subtransient reactance saturated 14 11,7 12,9 11, 11, T"d Subtransient time constant X"q Quadra. axis subtransient reactance saturated 16,3 13,1 14, 12, Xo Zero sequence reactance unsaturated,9,7,8,8,9.9 X2 Negative sequence reactance saturated 1,2 12, 13,8 12,1 12, 14.3 Ta Armature time constant Other data - Class H / 48 V io (A) No load excitation current,9,9,9,9,9.8 ic (A) Full load excitation current 3,6 3,2 3, 3,2 3,3 3.2 uc (V) Full load excitation voltage ms Recovery time (DU = 2 % trans.) kva Motor start. (DU = 2% sust.) or (DU = % trans.) % Transient dip (rated step load) - PF :,8 LAG 13,3 1,9 11,7 1, W No load losses W Heat rejection New New 6

7 Transient voltage variation 48V - 6 Hz Load application ( AREP or PMG system) 2 % S 4 % Voltage dip 1 1 M 6 M 7 L 9 L 1 L kva kva at,8 power factor Load rejection (AREP or PMG system) 2 % S 4 M 6 M 7 % Voltage rise 1 1 L 9 L 1 L kva kva at,8 power factor Motor starting (AREP or PMG system) 3% S 4 M 6 M 7 L 9 L 1 L 11 2 % Voltage dip % kva 88,7 Locked rotor 1) For a starting P.F. other than,6, the starting kva must be multiplied by K = Sine Ø /,8 Calculation example for a different P.F. : Starter motor kva calculated at.4 P.F. = 7 kva Sin Ø,4 =,916 K = 1,14 kva corrected = 88,7 kva Voltage dip corresponding to L11 = 1 %. 2 ) For voltages other than 48V (Y), 277V ( ), 24V (YY) at 6 Hz, then kva must be multiplied by (48/U) 2 or (277/U) 2 or (24/U) 2. 7

8 3 phase short-circuit curves at no load and rated speed (star connection Y) 1 LSA 49.1 S4 Current (A) 1 1 Symmetrical Asymmetrical time (ms) 1 LSA 49.1 M6 Current (A) 1 1 Symmetrical Asymmetrical time (ms) 1 LSA 49.1 M7 Current (A) 1 1 Symmetrical Asymmetrical time (ms) Influence due to connexion Curves shown are for star connection (Y). For other connections, use the following multiplication factors : - Series delta : Current value x 1,732 - Parallel star : Current value x 2 8

9 3 phase short-circuit curves at no load and rated speed (star connection Y) 1 LSA 49.1 L9 Symmetrical Asymmetrical Current (A) time (ms) 1 LSA 49.1 L1 Symmetrical Asymmetrical Current (A) time (ms) 1 LSA 49.1 L11 Symmetrical Asymmetrical 1 Current (A) Influence due to short-circuit. Curves are based on a three-phase short-circuit. For other types of short-circuit, use the following multiplication factors : time (ms) 3 phase 2 phase L - L. 1 phase L - N. Instantaneous (Max) 1,87 1,3 Sustained 1 1, 2,2 Max sustained duration (AREP/ PMG) 1 sec. sec. 2 sec. 9

10 Single bearing dimensions LSA Pole Detail : LSA 49.1 L11 Flange SAE : & AH 1,7 Xg CF AH 17 CF Xg L LB ,3 AVR access R Option Y DIA, X eq. sp. hole on U PCD 11 1' 7 68 Ø 883 -,127 Ø N Air outlet -, -,1 Ø BX , C Ø P -,127 Ø N -, -,1 Ø BX Air outlet 6 W 216 C Ø 742 Air inlet x 2 hole Ø 3 Ø 23 Option PMG Diode access Ø DIA, 16 eq. sp. hole on M PCD Frame dimensions (mm) Coupling TYPE L maxi without PMG LB C Xg Weight (kg) LSA 49.1 S Flex plate LSA 49.1 M Flange S.A.E. 1 * X LSA 49.1 M Flange S.A.E 1/2 * X LSA 49.1 L Flange S.A.E. X X LSA 49.1 L Flange S.A.E. X LSA 49.1 L (*) : not available for LSA 49.1 L11 Flange dimensions (mm) Flex plate dimensions (mm) S.A.E. P N M W R CF S.A.E. BX U X Y AH , ,7 438, ,4 1/ ,2 619, , 42, ,7 * ,7 679, * ,4 8,9 6 1 (*) : see the flange detail for LSA 49.1 L11 SAE &. Torsional analysis data Xr (S4, M6, M7, L9, L1) Ø 13 Ø 13 Lr Ø 1 Ø 14 Ø 1 Xr (L11) Gravity center : Xr (mm), Rotor length Lr (mm), Weight : M (kg), Moment of inertia : J (kgm 2 ) : (4J = MD 2 ) Flex plate S.A.E. 14 Flex plate S.A.E. 18 TYPE Xr Lr M J Xr Lr M J LSA 49.1 S , ,76 LSA 49.1 M , ,39 LSA 49.1 M , ,39 LSA 49.1 L , ,3 LSA 49.1 L , ,3 LSA 49.1 L Ø 13 Ø 13 Lr Ø 1 Ø 14 Ø 1 New New 1

11 Two bearing dimensions 1 hole M24x Detail : LSA 49.1 L11 Flange SAE : 16 Xg 2 1 hole M24x 16 2 Xg L LB AVR access 11 1' 7 8,3 Ø R Option 68 Ø 883 -,127 Ø 647,7 Air outlet Ø 1 m , 29 Ø 73 Ø 647,7 -,127 Ø 1 m6 Air outlet Ø 742 Ø 23 PMG option Diode access 1 Air intlet x 2 hole Ø M12 DIA,16 eq.sp. hole on M PCD Frame dimensions (mm) TYPE L maxi without PMG LB M R Xg Weight (kg) LSA 49.1 S , LSA 49.1 M , LSA 49.1 M , LSA 49.1 L , LSA 49.1 L , LSA 49.1 L11* (*) : see the flange detail for LSA 49.1 L11 SAE. Torsional analysis data 16 Ø 1 Ø 11 Xr (S4, M6, M7, L9, L1) Ø 13 Lr Ø 1 Ø 14 Ø 1 Gravity center : Xr (mm), Rotor length Lr (mm), Weight : M (kg), Moment of inertia : J (kgm 2 ) : (4J = MD 2 ) TYPE Xr Lr M J LSA 49.1 S ,4 LSA 49.1 M ,67 LSA 49.1 M ,67 LSA 49.1 L ,31 LSA 49.1 L ,31 LSA 49.1 L Ø 1 Ø 13 Ø 13 Xr (L11) Lr Ø 1 Ø 14 Ø 1 New New 11

12 MOTEURS LEROY-SOMER 161 ANGOULÊME CEDEX - FRANCE RCS ANGOULÊME

3867 en / a

3867 en / a 3867 en - 9.24 / a Alternators LSA 49.1-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 49.1 alternator is designed to be suitable for typical generator applications, such

More information

3820 en / c

3820 en / c 38 en -.6 / c Alternators LSA 44.2-4 Pole Electrical and mechanical data SPECIALLY ADAPTED FOR APPLICATIONS The LSA 44.2 alternator is designed to be suitable for typical generator applications, such as:

More information

LSA 47.2 Low Voltage Alternators - 4 pole

LSA 47.2 Low Voltage Alternators - 4 pole LSA 47.2 36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Electrical and mechanical data LSA 47.2-36 to 6 kva - Hz / 46 to 7 kva - 6 Hz Specially adapted to applications The LSA 47.2 alternator is designed to be

More information

Low Voltage Alternators - 4 pole LSA 46.2

Low Voltage Alternators - 4 pole LSA 46.2 LSA 46.2 18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Electrical and mechanical data LSA 46.2-18 to 31 kva - Hz / 228 to 381 kva - 6 Hz Specially adapted to applications The LSA 46.2 alternator is designed

More information

LSA 51.2 Low Voltage Alternators - 4 pole

LSA 51.2 Low Voltage Alternators - 4 pole LSA 1.2 Low Voltage Alternators - 4 pole 186 to 2 kva - Hz / 223 to 3 kva - 6 Hz Electrical and mechanical data Specially adapted to applications The LSA 1.2 alternator is designed to be suitable for typical

More information

LSA 42.3 Low Voltage Alternators - 4 pole

LSA 42.3 Low Voltage Alternators - 4 pole LSA 42.3 Low Voltage Alternators - 4 pole 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 42.3 alternator is designed to be suitable for

More information

Low Voltage Alternators - 4 pole LSA 46.3

Low Voltage Alternators - 4 pole LSA 46.3 LSA 46.3 180 to 365 kva - 50 Hz / 225 to 435 kva - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 46.3 alternator is designed to be suitable for typical generator applications,

More information

Low Voltage alternators - 4 pole LSA 42.3

Low Voltage alternators - 4 pole LSA 42.3 Low Voltage alternators - 4 pole LSA 42.3 2 to 60 kva - 0 Hz / 31. to 7 kva - 60 Hz Electrical and mechanical data 42en - 12.02 / c SPECIALLY ADAPTED TO APPLICATIONS The LSA 42.3 alternator is designed

More information

LSA 53.2 Low Voltage Alternator - 4 pole

LSA 53.2 Low Voltage Alternator - 4 pole LSA 53.2 Low Voltage Alternator - 4 pole 400V - 50 Hz / 480V - 60 Hz Electrical and mechanical data Specially adapted to applications The LSA 53.2 alternators are designed to be suitable for typical generator

More information

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2

Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2 Alternators single phase dedicated - 4 Pole LSA 43.2 / LSA 44.2 5 to 135 kva Electrical and mechanical data 3542 en - 12.08 / f LSA 43.2 / 44.2-4 Pole SPECIALLY ADAPTED FOR SINGLE PHASE Dedicated single

More information

3363 en / e

3363 en / e 3363 en - 03.2005 / e alternators 4 Pole range : 5-2700 kva General features and ratings ALTERNATORS Summary Page 1 - RATING DEFINITION... 3 2 - INSULATION CLASS AND TEMPERATURE RISE... 3 3 - DERATING...

More information

LSA Rating Table Low Voltage Alternators - 4 pole

LSA Rating Table Low Voltage Alternators - 4 pole LSA Rating Table Low Voltage Alternators - 10 to 3300 kva - 50 Hz / 12.5 to 3900 kva - 60 Hz General features and ratings Summary 1 - RATING DEFINITION... 3 2 - INSULATION CLASS AND TEMPERATURE RISE...

More information

ALTERNATOR. LSA 36 - single-phase to 11.5 kva

ALTERNATOR. LSA 36 - single-phase to 11.5 kva 3692 en - 2009.07 / f ALTERNATOR LSA 36 - single-phase - 3.5 to 11.5 kva LSA 36 ALTERNATOR Developed using special modelling software to give optimised electrical performance Designed to supply power to

More information

3456 en / c. 1 to 20 MW Land and offshore applications

3456 en / c. 1 to 20 MW Land and offshore applications 3456 en - 12.2005 / c 1 to 20 MW Land and offshore applications POWER ALTERNATORS Generating Progress Gas or steam turbine application There is currently an enormous increase in energy requirements throughout

More information

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) SMALL GENERATOR INTERCONNECTION REQUEST (Application Form) Attachment 2 Transmission Provider: Bluestem Electric Cooperative, Inc. Designated Contact Person: Kevin Heptig Address: P.O. Box 5, Wamego, Kansas

More information

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw) Preface: This Facility Connection Standard applies to any connection to Westar Energy's

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.0 kw -.0 kw PHRT.00 kw -.0 kw 0.0

More information

Generation Application Part B: Technical Form

Generation Application Part B: Technical Form Generation Connections Generation Application Part B: Technical Form For all applications with total installed generation capacity greater than 16A per phase (>4). 01 May 2018 How to fill out this application

More information

Interconnection Application

Interconnection Application Interconnection Application Persons interested in applying for the interconnection of a distributed energy resource to the Utility s distribution system through the Fast Track or Study Processes are to

More information

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION Designated Contact Person: Mike Avant, Engineering Manager Address (for U.S. Mail Deliveries): Garkane Energy 1802 S Highway 89A Kanab, UT 84741 Telephone Number: (435) 644-5-26 E-Mail Address: mike.avant@garkane.com

More information

Connection of generation plant to distribution networks. Guidance on completing the application form

Connection of generation plant to distribution networks. Guidance on completing the application form Connection of generation plant to distribution networks It is possible to connect almost any generation plant to the distribution network and in order for the connection to meet the requirements of a new

More information

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8

The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8 Cogeneration Content Cogeneration Content The company 2 Our vision 3 Our mission 3 Marelli Motori Group of companies 4 Core markets 6 Our commitment to quality 8 Inspired solutions 10 No compromise on

More information

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information

Marine motors. 10/2 Orientation 10/2 Overview 10/3 Benefits 10/3 Application 10/3 Technical specifications 10/5 More information /2 Orientation /2 Overview /3 Benefits /3 Application /3 Technical specifications /5 More information /6 Type approved standard motors up to frame size 315 L /6 Overview /7 Type approved explosion-proof

More information

EC medium pressure axial fans.

EC medium pressure axial fans. EC medium pressure axial fans. The efficient system solution. The engineer s choice GreenTech EC technology in a new dimension. Thanks to these new new axial axial fans, fans, our our highly highly efficient

More information

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches. PRESSURE SWITCHES 8D-LT Electro-mechanical pneumatic pressure switches 8D-LT x Electro-mechanical pneumatic pressure switches Page -0 Page -0-0 8D-LT G/, / NPT or flange Microswitch with gold plated contacts

More information

EC medium pressure axial fans. The efficient system solution.

EC medium pressure axial fans. The efficient system solution. EC medium pressure axial fans. The efficient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly efficient GreenTech EC technology is now available for

More information

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame

Environmental Product Declaration FLSES. 3-phase induction motors with cast iron frame FLSES 3-phase induction motors with cast iron frame INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world leader in industrial

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: DQKAJ Frequency: 50 Hz Fuel type: Diesel kva rating: 2500 Standby 2000 Prime Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet:

More information

Environmental Product Declaration PLSES. 3-phase induction ODP motors

Environmental Product Declaration PLSES. 3-phase induction ODP motors PLSES 3-phase induction ODP motors INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems and the world leader in industrial alternators.

More information

Zero cross function. DIN track mounting *2. Screw mounting

Zero cross function. DIN track mounting *2. Screw mounting Solid State Contactors for Heaters Three-phase CSM_Three-phase_DS_E_3_1 Compact, Slim-profile SSRs with Heat Sinks. Solid State Contactors for Three-phase Heaters Reduced Installation Work with DIN Track

More information

Emissions level: EPA NSPS Stationary Emergency Tier 2

Emissions level: EPA NSPS Stationary Emergency Tier 2 Generator set data sheet Model: DQPAA Frequency: 60 Hz Fuel type: Diesel kw rating: 600 Standby Emissions level: EPA NSPS Stationary Emergency Tier 2 Exhaust emission data sheet: Exhaust emission compliance

More information

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 410 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 60 Hz Diesel 100 Standby 410 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating

Generator set data sheet. 80 Prime Emissions level: EPA Nonroad Tier 1. Fuel consumption. Engine Standby rating Prime rating Continuous rating Generator set data sheet Model: Frequency: Fuel type: kw rating: DGDB 50 Hz Diesel 85 Standby 80 Prime Emissions level: EPA Nonroad Tier 1 Exhaust emission data sheet: Exhaust emission compliance sheet:

More information

Dated: April 16, 2002

Dated: April 16, 2002 Central Hudson Gas & Electric Corporation (CHG&E) Application Process for Distributed Generators of Greater than 300 kva Connected in Parallel with the CHG&E Electrical Delivery System Dated: April 16,

More information

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white

3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A T-XAVs 1 on white 3-Position Selector Switch Devices, Non-Illuminated (Bul. 800T only) 3-Position Cylinder Lock Operator Cat. No. 800T-J41A 800 T J41 KC1 A a b c d e f a c (cont d) e (cont d) f (cont'd) Protection Rating

More information

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame

Product Environnemental Profile LSES. 3-phase induction motors with aluminium frame Product Environnemental Profile LSES 3-phase induction motors with aluminium frame INFORMATION ABOUT THE COMPANY Leroy-Somer is one of the world leaders in electromechanical and electronic drive systems

More information

Unit Coolers SKB. 4 kw 30,5 kw.

Unit Coolers SKB. 4 kw 30,5 kw. Unit Coolers SKB 4 kw 30,5 kw www.friga-bohn.com SKB range unit coolers are suitable for chilling or low temperature storage applications. 24 basic models with capacities ranging from 4 to 30.5 kw. NOMENCLATURE...

More information

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DGGAE 60 Hz Diesel 200 Standby 180 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

NEW MICRO STEPPER CONTROL SYSTEM Each Techno CNC Plasma Cutter is equipped with micro stepper motors that deliver continuous, high-speed performance. a Available in 2' x 2', 4' x 4', 4' x 8' and 5' x 10'

More information

Cannon Trident Connector System

Cannon Trident Connector System These are low installed cost connectors rated for up to 13 A and 250 V ac. They are typically used for circuit board and internal wiring applications. Snap Together connectors facilitate easy assembly

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted) 1DIVISION 15- MECHANICAL Section 15320 Fire Pumps 1.00 PART 1 -GENERAL 1.01 DESCRIPTION OF WORK: A. Provide pumps for fire suppression. 1.02 SECTION INCLUDES: A. Single Stage, Double Suction, 9100 Series

More information

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

1400 Prime 1125 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: Frequency: Fuel type: kva : DQGAH 50 Hz Diesel 1540 1400 1125 Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

Standby rating. Turbocharged and low temperature after-cooled

Standby rating. Turbocharged and low temperature after-cooled Generator set data sheet Model: Frequency: Fuel type: kva : DQGAN 50 Hz Diesel 1400 1275 1025 Emissions level: EPA NSPS Stationary emergency tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft

1540 Prime 1250 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Generator set data sheet Model: Frequency: Fuel type: kva : DQGAG 50 Hz Diesel 1700 1540 1250 Emissions level: EPA NSPS Stationary Emergency Tier 2 2g TA Luft Exhaust emission data sheet: Exhaust emission

More information

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops.

APPLICATIONS. This circulator is suitable for drinking water only. Hot water accelerated circulation in distribution loops. OPERATING LIMITS Flow rates up to : m /h Heads up to :, m Max. operating pressure : bar Max. loop temperature : +8 C Max. circulator temperature: C Max. ambient temperature : + C Water hardness (TH) :

More information

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3

135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Generator set data sheet Model: Frequency: Fuel type: kw rating: DQGAC 60 Hz Diesel 150 Standby 135 Prime Emissions level: EPA NSPS Stationary Emergency Tier 3 Exhaust emission data sheet: Exhaust emission

More information

Low and Medium Voltage Motor Repair

Low and Medium Voltage Motor Repair Low and Medium Voltage Motor Repair Service Center (Shop) Selection and Evaluation Guide Why do we repair electric motors? To realize the benefit of added running hours without incurring the higher expense

More information

MODEL 16ASX T/S - SPECIFICATION

MODEL 16ASX T/S - SPECIFICATION MODEL 16ASX T/S - SPECIFICATION 1.0 General Specifications TM There will be furnished one (1) only Grind Hog Model 16ASX T/S Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a

More information

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION Available range Unit type IH Heat pump IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS

More information

Simple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package.

Simple operation and a built-in bypass function make the CSX series a pleasure to use with many benefits in a tidy package. AuCom s CSX soft starters provide greater control over the starting and stopping of three phase motors. There are two product ranges: the CSX for a simple soft start control device, or the CSXi for an

More information

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL The RL series of burners covers a firing range from 154 to 2700 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 CO-GENERTATION POWER PLANT CONCEPT For dimensioning, design

More information

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT SECTION 23 05 12 GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. Also delete

More information

Axial Fans - Basic principles. Expertise, performance, innovation

Axial Fans - Basic principles. Expertise, performance, innovation Axial Fans - Basic principles Expertise, performance, innovation Fans Motors Control electronics Appendix 15 The truly space-saving axial fans from ebm-papst are used to exchange hot and cold air in all

More information

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993

MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993 IPS-M-EL-136 MATERIAL AND EQUIPMENT STANDARD FOR ROTATING ELECTRICAL MACHINES DIRECT CURRENT MOTORS ORIGINAL EDITION MAY 1993 This standard specification is reviewed and updated by the relevant technical

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

R-Series. Lead Wire Length (H, mm)

R-Series. Lead Wire Length (H, mm) Carbon Film Fixed Resistor Specifications Per I E C 6 0 1 1 5-1, I E C 6 0 1 1 5-4 d L H D MIL-R-10509 Features Conformal multi-layer coating (flame proof coating available) Color code per MIL & EIA standards

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing Switch Mode Power Supply S8VM (15/30/50/100/150/300/600/1,500-W Models) Power Supply Featuring OMRON s Unique, New Function with Compact Body Contributing to Machine Downsizing New undervoltage alarm function

More information

33-SDMS-02 SPECIFICATIONS FOR

33-SDMS-02 SPECIFICATIONS FOR SPECIFICATIONS FOR MV AUTOMATIC LINE SECTIONLIZER UP TO 36 KV This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS SECTION T I T L E PAGE NO.

More information

Bulkhead Feed-throughs

Bulkhead Feed-throughs 38999 series III Bulkhead Feed-throughs Connectors and interconnect systems for harsh environments The company designs, manufactures and markets high performance interconnect solutions for severe environments

More information

Largo & Allegro. Air Compressors. Largo & Allegro

Largo & Allegro. Air Compressors. Largo & Allegro Largo & Allegro Air Compressors Largo 110-160 & Allegro 110-180 ALUP Driven by technology. Designed by experience. ALUP Kompressoren has over 85 years of industrial experience. It is our ambition to offer

More information

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw

RIELLO 40 N SERIES. One Stage Heavy Oil Burners FIRING RATES HEAVY OIL. N kw N kw One Stage Heavy Oil Burners RIELLO 40 N SERIES The Riello 40 N series of one stage heavy oil burners, is a complete range of products developed to respond to any request for the use of heavy oil in heating

More information

MAY-16 REV B2

MAY-16 REV B2 Product Specification 108-20025 06-MAY-16 REV B2 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity (TE)

More information

Applications R46 K I P0 M

Applications R46 K I P0 M Overview The R46 Series is constructed of metallized polypropylene film encapsulated with self-extinguishing resin in a box of material that meets the requirements of UL 94 V 0. Applications For worldwide

More information

Type Type 2000 Transducers. I/P & E/P Transducers

Type Type 2000 Transducers. I/P & E/P Transducers Type 2000 I/P & E/P Description Principle of Operation The Type 2000 I/P and E/P transducers utilize closed-loop pressure feedback-control for precision pressure output and minimized effects of temperature,

More information

SBX 1000 In Situ Oxygen Transmitter

SBX 1000 In Situ Oxygen Transmitter Product Data Sheet PDS 106-360.A01 July, 2005 SBX 1000 SBX 1000 In Situ Oxygen Transmitter SBX FEATURES 12-month warranty Electronics mounted to probe saves on installation and material Advanced sensor

More information

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number PART 1 GENERAL 01 02 03 04 SCOPE Furnish and install Manual Transfer Switches (MTS) and

More information

37-SDMS-01 REV. 03 SPECIFICATIONS FOR

37-SDMS-01 REV. 03 SPECIFICATIONS FOR 37-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE MOLDED CASE CIRCUIT BREAKERS FOR SERVICE CONNECTIONS This specification is property of SEC and subject to change or modification without any notice CLAUSE

More information

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm DATASHEET - CI45E-200-RAL7032 Delivery program Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm Part no. CI45E-200-RAL7032 Catalog No. 090160 EL-Nummer (Norway) 2502339 Dimensions mm Product

More information

Power Quality Improvement in Distribution System Using Distribution Static Compensator

Power Quality Improvement in Distribution System Using Distribution Static Compensator Power Quality Improvement in Distribution System Using Distribution Static Compensator Jay Kumar Sharma 1, Om Prakash Mahela 2 and Sunil Agarwal 1 1 Department of Electrical Engineering, Apex Institute

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P125-72

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P125-72 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

SUGGESTED SPECIFICATIONS Pump Frames through 64132

SUGGESTED SPECIFICATIONS Pump Frames through 64132 TYPE HBB - HORIZONTAL SOLIDS-HANDLING WASTEWATER PUMPS Pump Frames 44081 through 64132 GENERAL Furnish and install Horizontal Flexible Coupled Dry Pit Pumping Units complete with all accessories and appurtenances

More information

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox

DRUM MOTOR 138LS 138.5Ø 0.10kW kW, with steel helical gearbox 8 DRUM MOTOR DRUM MOTOR 18LS 18.5Ø 0.10kW - 1.00kW, with steel helical gearbox Product description The drum motor 18LS is a very fl exible component thanks to the wide range of powers and speeds. Characteristics

More information

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Rosemount 1152 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4235 Rev BA Rosemount 1152 Rosemount 1152 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1971 and IEEE Std 344-1975 Mild environment

More information

Problem specification

Problem specification 1 of 6 pages University of Rochester Department of Electrical & Computer Engineering ECE227/427 Take-home Exam due: 4-30-10 You are to work entirely alone on this take-home exam. NO COLLABORATION IS ALLOWED.

More information

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V Rollair Air Compressors ROLLAIR 150E-150-180-220 AND ROLLAIR 150V-180V-240V Worthington Creyssensac Driven by technology. Designed by experience. Worthington Creyssensac has over 145 years of industrial

More information

The H-25/H-15 Gas Turbine A Product of Hitachi Quality

The H-25/H-15 Gas Turbine A Product of Hitachi Quality GKKP-08-012 Rev.0 The H-25/H-15 Gas Turbine A Product of Hitachi Quality The H-25 s fuel savings will repay your investment within a few years while allowing you a range of fuels from distillate to natural

More information

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers.

SECTION A. NEC Compliance: Comply with NEC as applicable to installation and construction of electrical power/distribution transformers. N 16461 DRY TYPE TRANSFORMERS PART 1 - GENERAL 1.01 WORK INCLUDED: A. Copper-wound transformer optimized for light loading, meeting US Department of Energy proposed Candidate Standard Level (CSL) 3 efficiency,

More information

M16 M20 M25 M207 M51 M100 M200

M16 M20 M25 M207 M51 M100 M200 Metal Film Fixed Resistor Specifications Per IEC 60115-1 MIL-R-10509 d L H D Features Conformal multi-layer coating Color code per MIL & EIA standards Special tin-plated electrolytic copper lead wire Products

More information

M A N U F A C T U R I N G R A N G E S S A L E S C O N T A C T S B U S I N E S S S E C T O R S

M A N U F A C T U R I N G R A N G E S S A L E S C O N T A C T S B U S I N E S S S E C T O R S 4016 en - 02.2006/a L E R O Y - S O M E R F O U N D R Y B U S I N E S S S E C T O R S ELECTRIC MOTORS, GEARBOXES, ALTERNATORS AIR AND REFRIGERATION COMPRESSORS TEXTILE MACHINERY AGRICULTURAL MACHINERY

More information

Rosemount 1153 Series D Alphaline Nuclear Pressure Transmitter

Rosemount 1153 Series D Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4388 Rev BA INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std 323-1974 and IEEE Std 344-1975 5.0 x 10 7 rads TID gamma radiation 7 g ZPA seismic 420 F (215.6 C) steam temperature

More information

Product Specification JUL 14 Rev. A1

Product Specification JUL 14 Rev. A1 Industrial SCSI Connector 1. Scope 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions of SCSI Connector. 2. Applicable Documents

More information

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G Specifications ➊ Front of Panel (Operators) Mechanical Ratings Description Plastic (8EP/ES) Metal (8EM/EB) Vibration (assembled to panel) 1 2 Hz, 1.52 mm max./1 G max. Shock and no damage at 1 G Degree

More information

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202-203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300-301 QUANTITY FOR

More information

Advice on Power Factor and Accuracy of Temperature Dependant Outputs

Advice on Power Factor and Accuracy of Temperature Dependant Outputs Advice on Power Factor and Accuracy of Temperature Dependant Outputs REPORT WP03749-EE-RP-0001 Rev. 1 3 September 2009 Advice on Power Factor and Accuracy of Temperature Dependant Outputs REPORT WP03749-EE-RP-0001

More information

DTS-HC High-Current Connectors

DTS-HC High-Current Connectors ROBUST DTS-HC High-Current Connectors Signal and power contacts in same housing Up to four 150 A or one 300 A high-current contacts Threaded coupling with self-locking mechanism for anti-vibration 100%

More information

APDRP SCHEME, WESCO. Technical Specification for 33KV Air Break Switch PART 1: SCOPE AND CONDITIONS

APDRP SCHEME, WESCO. Technical Specification for 33KV Air Break Switch PART 1: SCOPE AND CONDITIONS PART 1: SCOPE AND CONDITIONS 1. SCOPE This specification covers the design, engineering, manufacture, testing, supply, delivery, off-loading and performance requirements of 33kV, 200 amp, triple pole Gang

More information

Design Objective

Design Objective Design Objective 108-115096 Low profile 5A battery connector 2015.03.03 REV:A 1.0 Scope: 1.1 Content: This specification covers the requirements for product performance, test methods and quality assurance

More information

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators Bulletin F. mm Push Buttons Product Overview Bulletin F Plastic and Metal Operators. mm mounting hole IP/, Type /X/ Internationally rated operators Table of Contents See below. TABLE OF CONTENTS Page Specifications...

More information

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011 100 Best Efficiency Point 90 80 70 TDH (ft) 60 50 40 30 20 10 The curve reflects maximum performance characteristics without exceeding full load (Nameplate) horsepower. Operation is recommended near the

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators (63 kv- 400 kv)

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators (63 kv- 400 kv) Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Substation Insulators

More information

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

Rosemount 1154 Alphaline Nuclear Pressure Transmitter Product Data Sheet 00813-0100-4514 Rev BA Rosemount 1154 Rosemount 1154 Alphaline Nuclear Pressure Transmitter INDUSTRY LEADING PERFORMANCE Qualified per IEEE Std. 323-1974 and IEEE Std. 344-1975 1.1 10

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING

More information

Participation in the sale of Energy Efficient Appliances

Participation in the sale of Energy Efficient Appliances Nepal Electricity Authority (A Government of Nepal Undertaking) Invitation of Proposals for Participation in the sale of Energy Efficient Appliances Issued by: Nepal Electricity Authority Energy Efficiency

More information

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH SPECIFICATIONS FOR LOAD BREAK SWITCH This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE CODES

More information

Rosemount 3154N Nuclear Qualified Pressure Transmitter

Rosemount 3154N Nuclear Qualified Pressure Transmitter Product Data Sheet Rosemount 3154N Nuclear Qualified Pressure Transmitter Rosemount 3154N INDUSTRY LEADING PERFORMANCE Qualified per: o IEEE Std 323-1974/1983/2003 o IEEE Std 344-1975/1987/2004 112 Mrad

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 CONTENTS Page - SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 40 203 PERFORMANCE CURVE 80 204 - CONSTRUCTIONS 300 SECTIONAL VIEW 300

More information