Split System Air Conditioner GSC13: 3-5 Tons GSC10: 7½ & 10 Tons

Size: px
Start display at page:

Download "Split System Air Conditioner GSC13: 3-5 Tons GSC10: 7½ & 10 Tons"

Transcription

1 GS ommercial Split System Air onditioner GS13: 3-5 Tons GS10: 7½ & 10 Tons ontents Nomenclature... 2 Product Specifications... 3 Performance Data... 5 Wiring Diagram... 6 Dimensions... 8 Accessories... 8 Standard Features Energy-efficient compressor Quiet operating top discharge High-efficiency copper tube/aluminum fin coil For use with R-22 refrigerant and charged with inert gas for shipping Brass liquid and suction service valves Factory-installed filter drier ontactor with lug connections Ground lug connection ETL Listed abinet Features Goodman brand sound control top design Steel louver coil guard protects the coil from damage and adds strength to unit Bottom pan rails elevate unit above slab Heavy-gauge galvanized-steel cabinet Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval When properly anchored, meets the 2001 Florida Building ode unit integrity requirements for hurricane-type winds (Anchor bracket kits available.) * omplete warranty details available from your local dealer or at SS-GS 1/17 Supersedes 10/12

2 Nomenclature G S A A ,5 6,7, Brand Engineering * G Goodman brand Minor Revision Engineering * Product ategory Major Revision S Split System Electrical Unit Type 3 = 208/230 V, 3 Phase, 60 Hz ondenser R = 460 V, 3 Phase, 60 Hz H Heat Pump R- 22 Nominal apacity Efficiency Tons 090 7½ Tons SEER Tons Tons EER Tons * Neither used for order entry 2 SS-GS

3 GS13 ommercial Product Specifications GS B* GS * GS B* GS * GS B* ooling apacities Tonnage SEER Decibels ompressor RLA / LRA 9.9/ / / / /58 Type Scroll Scroll Scroll Scroll Scroll ondenser Fan Motor Horsepower 1/4 1/4 1/4 1/4 1/4 FLA Refrigeration System Liquid Valve Size ( O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" Suction Valve Size ( O.D.) 1⅛" 1⅛" 1⅛" 1⅛" 1⅛" Refrigerant harge Valve Type Sweat Sweat Sweat Sweat Sweat Electrical Data A Volts/ Hz / / / / / 60 Min. ircuit Ampacity ¹ Max. Overcurrent Device ² Min / Max Volts 197/ / / / /506 Electrical onduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes; extensive wire runs will require larger wire sizes ² Must use time-delay fuses or HAR-type circuit breakers of the same size as noted. ³ Installer will need to supply ¾ to ⅞ adapters for suction line connections. 4 Installer will need to supply ⅞ to 1⅛ adapters for suction line connections. Notes Always check the S&R plate for electrical data on the unit being installed. Unit is charged with refrigerant for 15 of ⅜ liquid line. System charge must be adjusted per Installation Instructions Final harge Procedure. SS-GS 3

4 GS10 ommercial Product Specifications GS A* GS A GS B* GS B* ooling apacities Tonnage 7½ 7½ EER/IEER 11.2/ / / /11.2 Decibels ompressor RLA / LRA 25.6 / / / / 114 Type Scroll Scroll Scroll Scroll ondenser Fan Motor Horsepower FLA Refrigeration System Liquid Valve Size ( O.D.) ⅝" ⅝" ⅝" ⅝" Suction Valve Size ( O.D.) (7½ tons) 1⅜" 1⅜" 1⅜" 1⅜" Suction Valve Size ( O.D.) (10 tons) 1⅝" 1⅝" 1⅝" 1⅝" Refrigerant harge Valve Type Sweat Sweat Sweat Sweat Electrical Data A Volts/ Hz / / / / 60 Min. ircuit Ampacity ¹ Max. Overcurrent Device ² Min / Max Volts 197/ / / / 506 Electrical onduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" Ship Weight (lbs) ¹ Wire size should be determined in accordance with National Electrical odes; extensive wire runs will require larger wire sizes ² Must use time-delay fuses or HAR-type circuit breakers of the same size as noted. ³ Installer will need to supply ¾ to ⅞ adapters for suction line connections. ⁴ Installer will need to supply ⅞ to 1⅛ adapters for suction line connections. Notes Always check the S&R plate for electrical data on the unit being installed. Unit is charged with refrigerant for 15 of ⅜ liquid line. System charge must be adjusted per Installation Instructions Final harge Procedure. 4 SS-GS

5 Performance Data Outdoor Indoor Units ooling Ratings Unit oils/air Handlers Furnaces Total¹ Sens.¹ SEER² EER³ FM AHRI # GS130363B* A*F3642*6*+EEP 33,400 24, , GS130483* A*F4961*6A*+EEP 44,500 33, , GS130484B A*F4961*6A*+EEP 44,500 33, , GS130603* A*F4961*6A*+EEP 53,000 38, , GS130604B A*F4961*6A*+EEP 53,000 38, , ¹ Energy Efficiency 80 F/67 F Inside - 95 F ² Integrated Energy Efficiency Ratio Notes Always check the S&R plate for electrical data on the unit being installed. When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. EEP: Order from Service Dept. Part No. B or new Solid State Board B S. Part No. B is not interchangeable with B S. The Goodman Gas Furnace contains the EEP cooling time delay. Outdoor Model Indoor oil ooling apacity (BTU/h) Total Sensible EER¹ IEER² GS100903AD AR090 87,000 62, GS100904A AR090 87,000 63, GS101203B* AR ,000 82, GS101204B* AR ,000 80, ¹ Energy Efficiency 80 F/67 F Inside - 95 F ² Integrated Energy Efficiency Ratio Notes Always check the S&R plate for electrical data on the unit being installed. When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. EEP: Order from Service Dept. Part No. B or new Solid State Board B S. Part No. B is not interchangeable with B S. The Goodman Gas Furnace contains the EEP cooling time delay. SS-GS 5

6 GS13 Wiring Diagram L1 L3 L2 OMP F AUX MAIN MAIN AUX M PU BR ONTROL BOX BL L1 L2 L3 PU F OMP Wiring is subject to change. Always refer to the wiring diagram or the Warning unit for the most up-to-date wiring. LVJB OUTDOOR POWER SUPPLY SEE RATING PLATE Y NOTE 1 BL LVJB OLOR ODE BLAK BL BLUE BR BROWN OR ORANGE PU PURPLE RED WH WHITE YELLOW WIRING ODE FATORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTNAL HIGH VOLTAGE M FIELD WIRING HIGH VOLTAGE LOW VOLTAGE BR Y EQUIPMENT GROUND USE OPPER ONDUTORS ONLY OMPONENT ODE ONTATOR M OUTDOOR FAN MOTOR OMP OMPRESSOR F FAN APAITOR INTERNAL OVERLOAD LVJB LOW VOLTAGE JUNTN BOX NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOK & INDOOR THERMOSTAT. ONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITN. USE N.E.. LASS 2 WIRE 0140R00016P High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 6 SS-GS

7 GS10 Wiring Diagram Y NOTE 1 BL LVJB L1 L3 L2 OLOR ODE BLAK BL BLUE BR BROWN OR ORANGE PU PURPLE RED WH WHITE YELLOW OMP F AUX MAIN MAIN AUX M ONTROL BOX LVJB OUTDOOR POWER SUPPLY SEE RATING PLATE BL L1 L2 L3 PU WIRING ODE FATORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTNAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE M F BR Y EQUIPMENT GROUND USE OPPER ONDUTORS ONLY OMPONENT ODE ONTATOR M OUTDOOR FAN MOTOR OMP OMPRESSOR F FAN APAITOR INTERNAL OVERLOAD LVJB LOW VOLTAGE JUNTN BOX NOTES: 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOK & INDOOR THERMOSTAT. PU BR ONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITN. USE N.E.. LASS 2 WIRE OMP 0140R00016P Wiring is subject to change. Always refer to the wiring diagram or the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-GS 7

8 Dimensions W D Model Dimensions W" D" H" GS130363* ¼ GS130483* ¼ GS130484* ¼ GS130603* GS130604* GS100903* 35½ 35½ 41½ GS100904* 35½ 35½ 41½ GS101203* 35½ 35½ 41½ GS101204* 35½ 35½ 41½ Accessories A-20 FSK01A¹ Model Anchor Bracket Kit Freeze Protection Kit Description HPTD18-60 HP8-60 LAKT01 Digital room thermostat with 1-stage cool/1-stage heat Standard room thermostat with 1-stage cool/1-stage heat Low-Ambient Kit ontains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations Goodman Manufacturing ompany, L.P. Houston, Texas Printed in the USA. 8 SS-GS