1 Communicating directly to the PLC, DCS, HMI Designed to support great flexibilities in number and type of I/O signals. Working with open-architecture networks, these products easily communicate to today s most popular HMI software packages and DCS/PLCs. ISP 9

2 3F R6 / R Series FUNCTION MODEL I/O Slot Base x=s, N or D Base ( I/O slots+ Network Module (mm wide)) R6x-BSA Base ( I/O slots+ Network Module (36.5mm wide)) R6x-BSB Base ( I/O slots for extension) R6x-BSP Power Module DC Power Supply Module R6x-PF AC Power Supply Module R6-PSM Network Module Modbus 3 ch. R6-NM 6 ch. R6-NM Modbus/TCP (Ethernet) 3 ch. R6-NE 6 ch. R6-NE DeviceNet 6 ch. R6-ND PROFIBUS-DP 6 ch. R6-NP CC-Link Ver..0; Analog 6 ch. R6-NC Ver..00; Analog 6 ch. R6-NC3 T-Link R6-NF FUNCTION CH MODEL Analog Input Module (isolated) x=s, N or D DC Voltage Input R6x-SV DC Current Input R6x-SS Thermocouple Input R6x-TS RTD Input R6x-RS -0mA Input with Excitation R6x-DS Analog Output Module (isolated) DC Voltage Output R6x-YV DC Current Output R6x-YS Discrete Input Module Discrete Input Di R6x-DA Discrete Output Module NPN Transistor Output Do R6x-DCA PNP Transistor Output Do R6x-DCB Blank Filler Module Blank Filler Module --- R6x-DM R Series R6S: tension clamp type R6N: screw terminal type R6D: euro terminal type R Series 6-UNIT Series MBC / MBD FUNCTION MODEL Universal Input Module ( points; isolated) RZMS-U Thermocouple & DC Input Module ( points; isolated) RMS-GH Thermocouple & DC Input Module (6 points) RM-GH RD-GH RC-GH RTD & Potentiometer Input Module ( points) RM-J Contact I/O Module ( totalized counter inputs, contact inputs and outputs) RM-P Contact Input Module (3 points) RM-A Contact Output Module (3 points) RM-D Data sheets available on Web in PDF. Visit M- Data Library at ISP

3 F 33 FUNCTION MODEL FLEX NETWORK Basic Module Discrete Input, 6 points R7M-DA6 R7E-DA6 R7D-DA6 R7C-DA6 R7L-DA6* R7ML-DA6 R7FN-DA6 R7HL-DA6 6 points R7M-DC6A R7E-DC6A R7D-DC6A R7C-DC6A* 5 R7L-DC6A* R7ML-DC6A R7FN-DC6A R7HL-DC6A 6 points R7M-DC6B R7E-DC6B R7D-DC6B R7C-DC6B* 5 R7L-DC6B* R7ML-DC6B R7FN-DC6B R7HL-DC6B Discrete Input & R7L-DAC6* R7FN-DAC6A R7HL-DAC6A points each Discrete Input & R7FN-DAC6B R7HL-DAC6B points each Independent I/O Common Discrete Input & R7HL-DAC6ES points each Relay Contact Output, points R7M-DCC* R7D-DCC* 6 R7C-DCC* R7FN-DCC R7HL-DCC Relay Contact Output, points R7C-DCE* Remote Control Relay Control, points Remote Control Relay Control, points R7C-RR* R7L-RR* DC Voltage / Current Input, points DC Voltage / Current Input, points (high speed, ) R7M-SV R7E-SV R7D-SV R7C-SV R7L-SV* R7ML-SV R7FN-SV R7HL-SV R7FN-SVF R7HL-SVF Thermocouple Input, points R7M-TS R7E-TS R7D-TS R7C-TS R7L-TS* R7ML-TS R7FN-TS R7HL-TS RTD Input, points R7M-RS R7E-RS R7D-RS R7C-RS R7L-RS* R7ML-RS R7FN-RS R7HL-RS Thermistor Input, points R7C-RTA Potentiometer Input, points R7M-MS R7E-MS R7D-MS R7C-MS AC Current Input, points R7M-CTE R7E-CTE R7D-CTE R7C-CTE DC Voltage Output, points R7M-YV R7E-YV R7D-YV(A) R7C-YV R7L-YV* R7ML-YV R7FN-YV R7HL-YV DC Current Output, points R7M-YS R7E-YS R7D-YS(A) R7C-YS R7L-YS* R7ML-YS R7FN-YS R7HL-YS Extension Module Discrete Input, points R7M-EA R7E-EA R7D-EA R7C-EA R7L-EA R7ML-EA Discrete Input, 6 points R7M-EA6 R7E-EA6 R7D-EA6 R7C-EA6 R7L-EA6 R7ML-EA points 6 points points 6 points R7M-ECA R7E-ECA R7D-ECA R7C-ECA R7L-ECA R7ML-ECA R7M-EC6A R7E-EC6A R7D-EC6A R7C-EC6A R7L-EC6A R7ML-EC6A R7M-ECB R7E-ECB R7D-ECB R7C-ECB R7L-ECB R7ML-ECB R7M-EC6B R7E-EC6B R7D-EC6B R7C-EC6B R7L-EC6B R7ML-EC6B Relay Contact Output, points R7C-ECC R Series 6-UNIT Series MBC / MBD Gateway Module Gateway Module R7G *: Momentary or totalized pulse input *: One-shot output available *3: Momentary or totalized pulse input, one-shot output available *: Totalized pulse input is available when input extension module is connected *5: Selectable with extension modules R7C-ECxA, R7C-ECxB, R7C-ECC *6: Not usable with extension modules HLS is the abbreviation for High-speed Link of Step Technica Co., Ltd. ISP Specifications are subject to change without notice. 33

4 3F R3 / R Series 6-UNIT Series MBC / MBD 3 Base Installation Base R3-BS R5-BS Installation Base (free I/O address) R3-BSW --- Extender Power Module Base --- R5-EX Power Module Power 750mA R3-PS --- Supply.5A --- R5-PS Module A R3-PS3 --- Network Module Modbus R3-NM R5-NM Modbus/TCP (Ethernet) R3-NE R5-NE Analog 6 ch. R3-ND R5-ND DeviceNet Analog 3 ch. R3-ND R5-ND Analog 6 ch. R3-ND3 --- DPV R3-NP --- PROFIBUS Analog 6 ch. --- R5-NP Analog 3 ch. --- R5-NP Ver..0; Analog 6 ch. R3-NC R5-NC CC-Link Ver..0; Analog 3 ch. R3-NC R5-NC Ver. R3-NC3 --- LONWORKS R3-NL --- R3-NL --- T-Link R3-NF R5-NF FL-net R3-NFL --- Network Module (gateway) Modbus (Ver..0) R3-GM --- Modbus/TCP (Ethernet) R3-GE --- DeviceNet Analog 6 ch. R3-GD --- CC-Link (Ver..0/.00) R3-GC --- FL-net (OPCN-) R3-GFL --- Analog Input Module (isolated) Universal Input R3-US R3-SV R5-SV millivolt Input R3-SVA R5T-SV DC Voltage Input wide span voltage R3-SVB R5-SV R3-SVC R5T-SV R3-SV R3Y-SV millivolt Input R3-SVA wide span voltage 6 R3-SVB R3-SVC R3-SVN R3Y-SVN R3S-SVN R3-SV6N R3Y-SV6N R3-SS R5-SS R3-SS R5T-SS R3Y-SS R5-SS DC Current Input R3-SSN R5T-SS R3Y-SSN R3S-SSN R3-SS6N R3Y-SS6N R3-TS R5-TS Thermocouple Input R3-TS R5T-TS R5-TS R5T-TS R3-RS R5-RS R3-RSA R5T-RS high accuracy R3S-RSA R5-RS RTD Input R3-RS R5T-RS R3Y-RS high resolution R5-RSA high accuracy R3-RSA high resolution R5-RSA R3-RSB R3-MS R5-MS Potentiometer Input R3-MS R5-MS R3Y-MS R3-DS R5-DS -0mA Input R3-DSA R5T-DS with Excitation R3-DSN R5-DS R3Y-DSN R5T-DS Strain Gauge Input R3-LC CT Input R3-CT R5T-CT R5T-CT Zero-phase Current Input R3-CZ R3-CTA R5T-CTA R3-CTB R5T-CTA AC Current Input R3-CTC (clamp-on current sensor use) R3-CTA R5T-CTB R3-CTB R5T-CTB R3-CTC AC Voltage Input R3-PT R5T-PT R5T-PT AC Power Input input circuits R3-WT AC Power Input R3-WTA (clamp-on current sensor use) input circuits R3-WTB Multi Power Input system R3-WT R3-WTA system Multi Power Input R3-WTB (clamp-on current sensor use) or system R3-WTU Data sheets available on Web in PDF. Visit M- Data Library at ISP

5 R3 / F 35 Analog Output Module (isolated) R3-YV R5-YV DC Voltage Output R3S-YV R5T-YV R3-YV R5-YV R3Y-YV R5T-YV R3-YS R5-YS DC Current Output R3Y-YS R5T-YS R3S-YS R5-YS R5T-YS Pulse I/O Module (isolated) R3-PA R5-PA Totalized Pulse Input Pi Pi R3S-PA R5T-PA R3-PA Pi 6 R3Y-PA High Speed Totalized Pulse Input Pi R3-PAA Low Speed Totalized Pulse Input Pi R3-PAB High Speed Pulse Input Pi R3-PA Encoder Input Pi R3-PA Pulse Output Po 6 R3-PC6A R5-PC Po R5T-PC Analog Input Module with Transmitter Output (isolated) DC Voltage Input R5-SVA DC Current Input R5-SSA Thermocouple Input R5-TSA RTD Input R5-RSA Potentiometer Input R5-MSA -0mA Input with Excitation R5-DSA Alarm Module (isolated) DC Voltage Input R3-AV R3-AV DC Current Input R3-AS R3-AS Thermocouple Input R3-AT RTD Input R3-AR mA Input with Excitation R3-AD Discrete I/O Module R3-DA6 R5-DA Di Discrete Input Di 6 R3Y-DA6 R5T-DA R3S-DA6 Di 6 R5-DA6 R3-DA6A Di 6 Discrete Input R3Y-DA6A (with excitation supply) Di 3 R3-DA3A Di 6 R3-DA6A AC Contact Input Di 6 R3-DA6B Discrete Input / Output Di, Do R3-DAC R3S-DAC Discrete Input / Output Di, Do R3-DAC6A R3S-DAC6A Relay Contact Output Do 6 R3-DC6 R5-DC Do R3Y-DC6 R5T-DC Do 6 R3-DC6A Do 6 R5-DC6 Open Collector Output (NPN transistor) Do 3 R3-DC3A Do 6 R3-DC6A Triac Output Do 6 R3-DC6B Do 6 R3-DC6C PNP Transistor Output Do 3 R3-DC3C Do 6 R3-DC6C (relay contact) Do 6 R3-PD (NPN transistor) Do 6 R3-PD6A (triac) Do 6 R3-PD6B (PNP transistor) Do 6 R3-PD6C Remote Control Relay R3-RR Do Control R3S-RR BCD Code I/O Module BCD Code Input 7-digit BCD R3-BA3A BCD Code Output 7-digit BCD R3-BC3A Blank Filler Module Blank Filler Module --- R3-DM --- R5-DM R Series 6-UNIT Series MBC / MBD ISP Specifications are subject to change without notice. 35

6 36 F Other Series Field Network Modules Interfacing analog I/O signals from/to 0-RACK or -RACK modules Palm-top size plug-in module 60-UNIT Field Network Modules 6-UNIT Series Interfacing analog I/O signals from/to Mini-M or Pico-M modules Palm-top size plug-in module 6-UNIT R Series 6-UNIT Series MBC / MBD Communication Controllers MBC / MBD Wide selection of Mini-M series signal conditioner inputs CC-Link and DeviceNet interface Direct interface of various field signals including AC energy and pneumatic to a PLC Power supply to individual modules via the backplane bus Max. 0 km Transmission via Twisted-pair Cable Simple I/O module configuration No software programming required Interfacing field signals to the host PLC via Modbus RTU or Modbus/TCP Free combination of I/O signals Multiplex Transmission Simple Setting, Masterless Configuration Simple setting by matching the station address of paired modules No total system failure thanks to the masterless configuration All-in-one unit packaging I/O, power and network interface modules 36 Data sheets available on Web in PDF. Visit M- Data Library at ISP