1 Verificati Report No SHAEC Date: 16 Jun 2017 Page 1 of 13 Shanghai MXCHIP Informati Technology Co,Ltd 9th Floor, No5, Lane 2145 Jinshajiang Road, Putuo District, Shanghai Name : SGS Job No : Tested Basic Model No : Client Ref Informati : EMW5080 SP SH Date of Received : Verificati Period : - 14 Jun 2017 EMW5080 EMW5080(BLP), EMW5080(BLE), EMW5080(BSP), EMW5080(BSE), EMW5080(CLP), EMW5080(CLE), EMW5080(CSP), EMW5080(CSE) Verificati Requested : With reference to RoHS Directive 2015/863/EU amending 2011/65/EU Verificati Method : Verificati Result : Please refer to next page(s) Please refer to next page(s) Verificati : Note : Based the verificati results of the submitted samples, the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP), and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU The test results are related ly to the tested items The report shall not be reproduced except in full without the written approval of the testing laboratory Signed for and behalf of SGS-CSTC Standards Technical Services (Shanghai) Co, Ltd Helen Liu Approved Signatory

2 Verificati Report No SHAEC Date: 16 Jun 2017 Page 2 of 13 Verificati Method : 1 With reference to IEC :2013, review was performed for the samples disjointed from the submitted articles 2 With reference to IEC :2013, tests were performed for the samples indicated by the photos in this report (1) With reference to IEC :2013, screening by EDXRF spectroscopy (2) chemical test method a With reference to IEC :2013, determinati of Cadmium by ICP-OES b With reference to IEC :2013, determinati of Lead by ICP-OES c With reference to IEC :2013, determinati of Mercury by ICP-OES d With reference to IEC :2015 & IEC 62321:2008, determinati of Hexavalent chromium by Colorimetric method using UV-Vis e With reference to IEC :2015, determinati of PBBs and PBDEs by GC-MS 3 With reference to IEC (111/321/CD) determinati of phthalates by GC-MS

3 Verificati Report No SHAEC Date: 16 Jun 2017 Page 3 of 13 Part No Part Descripti Restricted Substances 1 EMW5080-Beige plastic (bracket) (socket) (PCB) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- IN ND Comply BBP --- IN ND Comply DEHP --- IN ND Comply DIBP --- IN ND Comply Date 2 EMW5080-Silvery metal (pin) (socket) (PCB) Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs PBDEs DBP BBP DEHP DIBP

4 Verificati Report No SHAEC Date: 16 Jun 2017 Page 4 of 13 Part No Part Descripti Restricted Substances 3 EMW5080-Silvery metal (block) (socket) (PCB) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs PBDEs DBP BBP DEHP DIBP Date 4 EMW5080-White plastic (label) (shielding cover) (PCB) Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- IN ND Comply BBP --- IN ND Comply DEHP --- IN ND Comply DIBP --- IN ND Comply

5 Verificati Report No SHAEC Date: 16 Jun 2017 Page 5 of 13 Part No Part Descripti Restricted Substances 5 EMW5080-Silvery metal (shielding cover) (PCB) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs PBDEs DBP BBP DEHP DIBP Date 6 EMW5080-Black IC1 (body) (PCB) Pb IN --- ND Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- BL --- Comply BBP --- BL --- Comply DEHP --- BL --- Comply DIBP --- BL --- Comply

6 Verificati Report No SHAEC Date: 16 Jun 2017 Page 6 of 13 Part No Part Descripti Restricted Substances 7 EMW5080-Black capacitor (body) (PCB) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- BL --- Comply BBP --- BL --- Comply DEHP --- BL --- Comply DIBP --- BL --- Comply Date 8 EMW5080-Silvery crystal resator (body) (PCB) Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- BL --- Comply BBP --- BL --- Comply DEHP --- BL --- Comply DIBP --- BL --- Comply

7 Verificati Report No SHAEC Date: 16 Jun 2017 Page 7 of 13 Part No Part Descripti Restricted Substances 9 EMW5080-Black IC2 (body) (PCB) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- BL --- Comply BBP --- BL --- Comply DEHP --- BL --- Comply DIBP --- BL --- Comply Date 10 EMW5080-Black IC3 (body) (PCB) Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- BL --- Comply BBP --- BL --- Comply DEHP --- BL --- Comply DIBP --- BL --- Comply

8 Verificati Report No SHAEC Date: 16 Jun 2017 Page 8 of 13 Part No Part Descripti Restricted Substances 11 EMW5080-Black IC4 (body) (PCB) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs BL Comply PBDEs BL Comply DBP --- BL --- Comply BBP --- BL --- Comply DEHP --- BL --- Comply DIBP --- BL --- Comply Date 12 EMW5080-Silvery metal (soldering tin) (PCB) Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs PBDEs DBP BBP DEHP DIBP

9 Verificati Report No SHAEC Date: 16 Jun 2017 Page 9 of 13 Part No Part Descripti Restricted Substances 13 EMW5080-Blue PCB (body) PHTH(2) () EU RoHS Pb BL Comply Cd BL Comply Hg BL Comply Cr(VI) BL Comply PBBs IN --- ND Comply PBDEs IN --- ND Comply DBP --- IN ND Comply BBP --- IN ND Comply DEHP --- IN ND Comply DIBP --- IN ND Comply Date

10 Verificati Report No SHAEC Date: 16 Jun 2017 Page 10 of 13 Remark : (1) (a) There are the results total Br while test items restricted substances are PBBs and PBDEs There is the result total Cr while test item restricted substances is Cr(VI) (b)results are obtained by EDXRF for primary screening, and further chemical testing by ICP-OES (for Cd, Pb, Hg), UV-Vis (for Cr(VI)) and GC-MS (for PBBs, PBDEs) is recommended to be performed, if the ccentrati exceeds the below warning value according to IEC :2013 (unit: ) Element Polymer Metal Cd BL (70-3σ)< X <(130+3σ) OL BL (70-3σ)< X <(130+3σ) OL Pb BL (700-3σ)< X<(1300+3σ) OL BL (700-3σ)< X <(1300+3σ) OL Hg BL (700-3σ)< X <(1300+3σ) OL BL (700-3σ)< X <(1300+3σ) OL Br BL (300-3σ)< X -- Cr BL (700-3σ)< X BL (700-3σ)< X Composite Materials LOD < X <(150+3σ) OL BL (500-3σ)< X<(1500+3σ) OL BL (500-3σ)< X <(1500+3σ) OL BL (250-3σ)< X BL (500-3σ)< X (c) BL = Below Limit, OL = Over Limit, IN = Incclusive, LOD = Limit of Detecti, -- = Not regulated (d) The XRF screening test for RoHS elements - The reading may be different to the actual ctent in the sample be of n-uniformity compositi (2) results of PHTH are for primary screening, and further chemical testing by GC-MS (for DBP, BBP, DEHP and DIBP) are recommended to be performed if the ccentrati exceeds the below warning value (unit: ) Compound DBP BBP DEHP DIBP Polymer BL 600< X BL 600< X BL 600< X BL 600< X (3) (a) = 00001%, MDL=Method detecti Limit, ND = Not Detected (<MDL), --- = Not cducted, - = Without BOM (b) Unit and MDL in wet chemical test Test Item Unit MDL Pb 10 Cd 10 Hg 10 DBP 100 BBP 100 DEBP 100 DIBP 100

11 Verificati Report No SHAEC Date: 16 Jun 2017 Page 11 of 13 The MDL for single compound of PBBs and PBDEs is 100, MDL of Cr(VI) for polymer, composite and leather sample is 10, MDL of Cr(VI) for metal sample is 010μg/cm² (c) =Metal sample a The sample is positive for CrVI if the CrVI ccentrati is greater than 013 μg/cm² The sample coating is csidered to ctain CrVI b The sample is negative for CrVI if CrVI is ND (ccentrati less than 010 μg/cm²) The coating is csidered a n-crvi based coating c The result between 010 μg/cm² and 013 μg/cm² is csidered to be incclusive - unavoidable coating variatis may influence the determinati Informati storage cditis and producti date of the tested sample is unavailable and thus Cr(VI) results represent status of the sample at the time of testing IEC series is equivalent to EN series < 25> (4) According to the declarati from applicant, the materials of Model "EMW5080" are the same as those in Model "EMW5080(BE), EMW5080(BP), EMW5080(CE), EMW5080(CP)" and its results for support the results of Model "EMW5080(BE), EMW5080(BP), EMW5080(CE), EMW5080(CP)" The applicant will take the respsibility of all discrepancy and risk

12 Verificati Report No SHAEC Date: 16 Jun 2017 Page 12 of 13 photo: SHAEC SHAEC

13 Verificati Report No SHAEC Date: 16 Jun 2017 Page 13 of 13 SHAEC SHAEC SGS authenticate the photo original report ly *** End of Report ***