Fume Cabinets. iab. Order by phone Order on-line Order by fax Website

Size: px
Start display at page:

Download "Fume Cabinets. iab. Order by phone Order on-line Order by fax Website"

Transcription

1 iab Standard bench height fume cupboards with vented storage below. 1200, 1500, 1800 and 2000mm long. Walk-in Fume cupboards - custom made Laboratory Fume Cupboards Setting the Standard A clear understanding of the British Standards, good laboratory design and air movement are essential in providing a safe laboratory environment. iab is considered to be one of the most experienced laboratory design companies in the UK with the ability to design and build laboratory environments to exacting requirements. Meeting your requirement As part of a project, fume cupboards can form a major portion of the overall design. Most fume cupboard requirements can be met using a range of standard designs and modular fume cupboard sizes. However, each project is unique and to achieve customer requirements iab realise that fume cupboards may have to be designed to suit a client s specific needs. All fume cupboards are designed and manufactured to BS 7258 (1994) Parts 1,2,3 & 4. Complete Service Bench-height fume cupboards Walk-in fume cupboards Water wash fume cupboards Custom-made fume cupboards Fixed volume fume extract systems Variable air volume extract systems Balanced air input systems Air conditioning and temperature controls CAD based design service Commissioning Annual face velocity testing service Standard Modular Fume Cupboards iab s portfolio includes a range of standard cabinets well designed to cope with a wide range of laboratory uses. Standard modules mean that iab can provide good quality cabinets at competitive prices. Walk-in Fume Cupboards Walk-in fume cupboards are mainly designed according to customer requirements to suit large static pieces of equipment. Vertical and horizontal sash arrangements are available. Water Wash Fume Cupboards Mains fed or recirculating water wash units are available in a range of standard sizes. Units are provided with rear water wash facility, mist eliminator and duct wash system. For more information on the iab range of laboratory fume cupboards please contact our Technical Office on Water wash fume cupboards - mains fed or recirculating. 386

2 Bigneat Ductless Fume Cabinets Bigneat filtration fume cabinets are a cost effective solution when fume, vapour or particulates removal is required remotely from ducted fume cupboards. The mobility of this type of cabinet ensures they can be sited in the most convenient location, locally to where the hazard containment is required Bigneat cabinets are manufactured to the highest standards and together with the latest Chemcap filters meet the world s most stringent standards: The AFNOR NFX class II and BS 7989:2001. The impregnants used in filter manufacture are hazard-free. Cabinets are manufactured from polyester coated steel. Aluminium uprights, anodised for added protection, offer exceptional structural strength to support the 8mm thick transparent acrylic panels that are easy to keep clean and offer excellent resistance to fire. No expensive ductwork necessary Operational in less than an hour Chemcap filtration efficiency is better than 99.9% Excellent access and visibility to working area Quiet operation, less than 50 db(a) and low power consumption Air velocity meter monitors the performance and face velocity After selecting the cabinet type, you then need to select the filter qualified for the type of gases or vapours that you will be handling, please see below for filter details. Bigneat cabinets are fitted with Chemcap Performance filters which have been developed following many years of research and development. They provide a filtration efficiency of 99.9% throughout the life of the filter, with no deterioration in performance. Model Air changes per min face velocity Internal dimensions 380x x x x x x520 (wxdxh), mm x580 x810 x810 x810 x810 External dimensions 410x x x x x x570 (wxdxh), mm x900 x1145 x1145 x1145 x1145 Base tray standard standard standard standard standard standard Filter size 1 x CP2 1 x CP3 1 x CP4 1 x CP4 1 x CP4 1 x CP4 Weight, kg Filter Options Filters of a predetermined type are supplied with the Bigneat cabinets. If you have any difficulty making your selection please contact our Technical Office on A chemical questionnaire will be supplied for completion once your enquiry is received, to ensure the correct selection of filter has been made. If your application generates gases or vapours, without dust and fumes or without liquid aerosols, you need to specify cabinet type C and then select a suitable CP chemical filter (see below). If your application generates gases and vapours, with dust and fumes or with liquid aerosols, you need to specify cabinet type NU and then select a suitable CP chemical filter (see below). A CP HEPA filter is also supplied. Specification Gas or vapour type Chemical filter type Polyvalent filter where organic vapours predominate OS Polyvalent filter where acid vapours predominate H+ Specifically for Formaldehyde F Specifically for Ammonia AM Specifically for radioactive Iodine RI (NU cabinets only)

3 Bigneat shown with (optional cupboard doors) Ductless Fume Cabinets (continued ) Ductless fume cabinets Ductless fume cabinets Cat. No Cabinet Type C Filter type Price Cat. No Cabinet Type NU Filter type Price C cabinet OS POA NU cabinet OS HP POA C cabinet H+ POA NU cabinet H+ HP POA C cabinet F POA NU cabinet F HP POA C cabinet AM POA NU cabinet AM HP POA NU cabinet Ri HP POA C cabinet OS POA NU cabinet OS HP POA C cabinet H+ POA NU cabinet H+ HP POA C cabinet F POA NU cabinet F HP POA C cabinet AM POA NU cabinet AM HP POA NU cabinet Ri HP POA C cabinet OS POA NU cabinet OS HP POA C cabinet H+ POA NU cabinet H+ HP POA C cabinet F POA NU cabinet F HP POA C cabinet AM POA NU cabinet AM HP POA NU cabinet Ri HP POA C cabinet OS POA NU cabinet OS HP POA C cabinet H+ POA NU cabinet H+ HP POA C cabinet F POA NU cabinet F HP POA C cabinet AM POA NU cabinet AM HP POA NU cabinet Ri HP POA C cabinet OS POA NU cabinet OS HP POA C cabinet H+ POA NU cabinet H+ HP POA C cabinet F POA NU cabinet F HP POA C cabinet AM POA NU cabinet AM HP POA NU cabinet Ri HP POA C cabinet OS POA NU cabinet OS HP POA C cabinet H+ POA NU cabinet H+ HP POA C cabinet F POA NU cabinet F HP POA C cabinet AM POA NU cabinet AM HP POA NU cabinet Ri HP POA Installation and commissioning (all models)* POA * It is a requirement of British Standard that a cabinet is installed, commissioned and a commissioning report provided. Installation and commissioning are not included in the prices above and can be priced on request. Please contact our Technical Office for more details Mobile trolley Bigneat cabinets may be placed directly on a work-surface, over a sink, or on a mobile trolley. In the latter option the cabinet is secured to the trolley and the integral base tray to ensure stability and safety. The trolley has four 130mm diameter castors, two of which are lockable. A shelf is included which is located at mid-height. It is manufactured from galvanised mild steel and protected with a white, acid resistant, anti-corrosion polyester coating. Height of the trolley is 890mm. The mobile trolley may be supplied with cupboard doors. For more details please contact our Technical Office on Cat. No Description Price Cat. No Description Price Trolley for cabinet 6003 POA Trolley for cabinet 1204 POA Trolley for cabinet 8004 POA Trolley for cabinet 1504 POA Trolley for cabinet 1004 POA Fluorescent lighting Cat. No Description Price Lighting, 11 watt fluorescent, suitable for all models* POA * Must be ordered at time of purchase. For details on the accessories above and on replacement filters. Please contact our Technical Office on

4 Astec Monair Plus and Monair Standard Fume Cupboards The Monair range is the latest recirculating fume cabinet from Astec; they offer stateof-the-art design combined with excellent value for money. The principle of filtration is simple; contaminated air is drawn through two separate filters with clean air recirculating back into the laboratory. Astec fume cabinets are used in a diverse range of applications, from standard laboratory usage, through to complex forensic applications. Translucent panels on all sides provide excellent visibility and a digital display indicates airflow velocity and other control data. All models feature a unique filter clamping system for safe and easy installation and removal of filters. Microprocessor control and monitoring system Robust construction of epoxy powder coated steel Hinged front panels for large equipment access and cleaning Profiled work tray; angled to assist cleaning Increased opening for ease of use (average width opening of 635mm on 1.0m model) Low airflow/fan failure alarm fitted on all models Monair Plus models feature filter and sash open alarms (optional on Monair Standard models) Optional safety filters are available to capture any breakthrough from the main filter Choice of filter types to remove both fumes and/or particulates Filter inspection window to confirm the correct filter is being used Conform to BS 7989: Monair - all models Controls Microprocessor control and monitoring system Alarms Plus models: low airflow/fan failure, filter breakthrough, sash open Standard models: low airflow/fan failure Construction Epoxy powder coated mild steel outer, acrylic sash, side and rear panels. Tray: GRP on Plus models, Polypropylene on Standard models Electrical supply 230V 50Hz, single phase (other voltages available on request) Unique filter clamping system Model Monair 750 Monair 1000 Monair 1250 Monair 1500 Monair 1750 Face velocity, m/s >0.5 >0.5 >0.5 >0.5 >0.5 Lighting, W 1 2x15 2x15 3x15 3x15 4x15 Noise, db(a) Fans 1x centrifugal IP44 2x centrifugal IP44 2x centrifugal IP44 2x centrifugal IP44 3x centrifugal IP44 External dimensions (wxdxh), mm 780x700x x700x x700x x700x x700x1220 Internal dimensions (wxdxh), mm 730x640x x640x x640x x640x x640x79 Working aperture (wxh), mm Plus models 410x x x x x345 Standard models 515x x x x x210 Weight 2, kg Filters Main filter size (wxdxh), mm 350x556x110 (all models) Number of main filters (10kg each) Safety filter size (wxdxh), mm 344x490x54 (all models) Number of safety filters (4kg each) Pre-filter size, mm 560x355 (95% efficiency) (all models) HEPA filter size (wxdxh), mm 350x556x110 (99.997% to 0.3 microns efficiency) (all models) Refer to filter matrix for filter choice. Carbon filters or HEPA filters may be fitted to the Monair range 1. Lighting is fitted on the Monair Plus models, but is optional on the Monair Standard models 2. Excluding filters 389

5 Astec Monair Plus and Monair Standard Fume Cupboards, continued Monair Plus 750 Fume cabinet. Fume enclosure, lighting, filter saturation alarm, low airflow/fan failure alarm, POA sash open alarm and sash closure lock, GRP spillage tray Monair Plus 1000 Fume cabinet supplied as above POA Monair Plus 1250 Fume cabinet supplied as above POA Monair Plus 1500 Fume cabinet supplied as above POA Monair Plus 1750 Fume cabinet supplied as above POA Monair Standard 750 Fume cabinet. Fume enclosure, polypropylene spillage tray and low airflow/fan failure alarm POA Monair Standard 1000 Fume cabinet supplied as above POA Monair Standard 1250 Fume cabinet supplied as above POA Monair Standard 1500 Fume cabinet supplied as above POA Monair Standard 1750 Fume cabinet supplied as above POA All units are supplied without filters, which must be ordered separately. See below for details on suitable filters. Accessories Cat. No. Description For Cabinet Price Stand with feet Monair 750, Monair Plus 750 POA Stand with feet Monair 1000, Monair Plus 1000 POA Stand with feet Monair 1250, Monair Plus 1250 POA Stand with feet Monair 1500, Monair Plus 1500 POA Stand with feet Monair 1750, Monair Plus 1750 POA Accessories for the Monair Plus models include: filter alarm (for acids); polypropylene spillage tray; gas services; water services; electrical sockets; stand with castors; electrical socket fitted to stand; Hazchem base unit; duct spigot & flange and gas detection system. Accessories for the Monair Standard models include: fluorescent lights; filter alarm (for solvents and acids); GRP spillage tray; gas services; water services; electrical sockets; stand with castors; electrical socket fitted to stand; Hazchem base unit; duct spigot & flange and gas detection system. Please contact our Technical Office on for details. Impregnated Carbon Filters Filter Choice Monair filtration fume cupboards are available with a range of filters or filter combinations to suit your requirements. Filters for older Astec fume cupboards are also available on request. Pre-filters - A Filtrete high performance filter designed to remove particulates from the air stream Main Filters - Various types of filter media are available for the main filter bed, most are impregnated activated carbon to provide a higher filter capacity for lower molecular weight organic compounds and inorganic gases and vapours. Multi layer filters are available on request. Safety Filters - These are optional on the Monair Plus and Monair Standard models. They capture any breakthrough from the main filter. Filters Filter Types Applications GP Solvent fume removal ACR Iodine, methyl iodide and radioactive materials ACM Mercury vapour AMM Dilute ammonia solutions ACI Volatile inorganic acids SUL Hydrogen sulphide and low molecular weight mercaptans CYN Cyanide type compounds FOR Formaldehyde Filter Types Applications ETH Diethyl ether MIL Solvent, acid fumes, hydrogen sulphide, cyanides, arsine OAL Odours from alkaline solutions OAC Odours from acid solutions (bacterial decay etc) HEP HEPA particulate filter (99.999%) MU Multi layer/special blended filter to cope with groups of compounds (made to order) PRF Filtrete pre-filter Filter reference Description Monair 5 Price Miniflow 8 Price Monair Main Price 4kg 8kg 10kg 001 GP General purpose filter for POA POA POA solvent fume removal 013 FOR Formaldehyde filter POA POA POA 030 HEP HEPA particulate filter POA POA POA 110 MU Multi layer filter (made to order) POA POA Pre-filters 300 PRF(6) Pre-filters, pack of POA POA 300 PRF(10) Pre-filters, pack of POA For pricing information for the other filter types, including safety filters for the Monair range please contact our Technical Office on for details. 390

6 Astec Monair 5 Bench Mounted Fume Cupboard The Monair 5 is a small bench mounted unit ideal for using or weighing small amounts of chemicals. Lighting is at the rear of the unit giving full illumination of the work surface. Carbon filters can be selected from a wide range to suit your application. The Monair 5 features a filter clamping system for safe and easy installation and removal of filters. A face velocity of >0.5 m/s ensures containment of fumes or particulates for operator safety. A visual alarm will alert the operator if the airflow falls to an unacceptable level. This compact unit can be moved to point of use and installed over existing work surfaces without the need for ducting. Spillage trays are available as an accessory. High operator protection Low airflow alarm Choice of carbon filters or HEPA filters Easy to clean work area Optional spillage tray No installation costs No ducting costs Miniflow 8 Bench Mounted Fume Cupboard The Miniflow 8 has been specifically designed to provide a ventilated work area with unrestricted access for those operations that are difficult to perform within a traditional fume cupboard. The downflow action takes contaminated air away from the operator and a visual alarm will indicate if the airflow falls to an unacceptable level. The stainless steel tray is removable for easy cleaning and access to the pre-filter. Integral lighting fully illuminates the work surface. Carbon filters can be selected from a wide range to suit your application. A filter clamping system for safe and easy installation and removal of filters is included. This unit can be moved to point of use and installed over existing work surfaces without the need for ducting. Polypropylene spillage trays are available as an accessory. Operator protection Choice of carbon filters or HEPA filters Low airflow alarm Optional polypropylene spillage tray Easy access with cutaway sides No installation costs Easy to clean removable base tray No ducting costs Model Monair 5 Miniflow 8 Airflow, m 3 /hr Face velocity, m/s >0.5 >0.4 Noise, db(a) External dimensions (wxdxh), mm 600x580x x600x800 Work area (wxd), mm 580x x430 Construction Epoxy coated mild steel Epoxy coated mild steel Clear acrylic sides/front/rear Stainless steel spillage tray Weight, kg Number of filters 1 (4kg) 1 (8kg) Electrical supply 230V/50Hz single phase 230V/50Hz single phase Monair 5 bench mounted fume cupboard with enclosure and head POA Miniflow 8 compact fume cupboard POA Units are supplied without filters, which must be ordered separately. See page 390 for details on suitable filters. Accessories for Monair Polypropylene spillage tray POA Filter saturation alarm (factory fitted) POA Accessories for Miniflow Polypropylene spillage tray POA

7 Bigneat Mini Cleantec 1/2 Mini Cleantec 2/4 Mini Cleantec Dust and Fume Containment Systems The Cleantec range of hazard containment systems is designed to remove dust and fumes at the source from your process or working environment. They are ideal for extraction at one to four points of use. Mini Cleantec Systems are extremely compact yet able to handle large volumes of dust and fumes. Apart from taking up very little space they are also easy to use and maintain. There are several features of the Mini Cleantec System that enable it to efficiently handle and absorb large volumes of chemical material. Central to this is the powerful centrifugal air-fan which incorporates automatic detection of airflow (by vacuum sensor). It is able to ensure a constant flow throughout the life of the dual filtration system and maintains containment efficiency at all times. Units can be self installed and maintained BACTIGUARD coating inhibits and destroys bacteria cells within ductwork and filters Robust, plastic construction provides excellent resistance to chemicals and acids Easy to clean (non-electronic parts are autoclavable) Quiet operation with low running costs HEPA filter with % efficiency (particles >0.3µm) Filter blocked audible alarm (optional) Filtration Stage 1 - Pre-Filter For removing large particles the Mini Cleantec System uses EU5 grade pre-filters as standard (mini-pleat pre-filters up to EU9 can be supplied, if required). The Mini Cleantec system is available in four configurations. Mini 1/2 Mini 1/ Mini 2/4 Mini 2/ Filtration Stage 2 - Combined HEPA/Carbon Filter Technology HEPA filter removes particles of 0.3µm or greater to a % efficiency. The carbon filters used (which can be tailored to your specific requirements) have highly efficient absorbance characteristics, they are chemically effective and have a high loading capability. Applications include the removal of organic and acid vapours, fine powders (for instance, during weighing), potentially radioactive vapours, smoke and fumes on the workbench or production line. The Mini Cleantec Systems are available in four configurations. Mini 1/2 may be configured for one 50mm arm or two 32mm arms. Mini 2/4 may be configured for two 50mm arms or four 32mm arms. Model Mini 1/2 Mini 2/4 Flow rate (max), m 3 /hr 100 (59cfm) 200 (118cfm) Wattage, W Voltage, V* 230 ±10% 230 ±10% Hose connection, mm 51 2x51 Sound levels, db(a) <60 <60 Controls Illuminated on/off switch (both models) Materials of construction Systems are manufactured from hi-grade acrylic-capped ABS, which is a high temperature material with an auto-ignition of 390 C. It is anti-static, corrosion resistant and has a high impact strength, high gloss surface. Dimensions (hxwxd), mm 284x275x x390x385 Weight, kg * 115V/60Hz versions are available. Please contact our Technical Office on for details. Cat. No Description Price Mini 1/2 Cleantec Systems arm option POA Supplied with: 1x50mm Flexible jointed arm, 1x50mm Pen-nib nozzle*, 1xBench clamp bracket, 1x1mtr - 50mm diameter flexible hose, 1x50mm Straight connector, 2x45-60mm Hose clip, 1x100-50mm Reducer, 1xHEPA/carbon filter*, 1xPre-filter pad arm option POA 2x32mm Flexible arm, 2xFlanged hood*, 2xBench clamp bracket, 1x50mm Equal tee, 2x50-32mm Reducers, 2x1mtr - 32mm diameter flexible hose, 2xHose cuffs, 1xHEPA/carbon filter*, 1xPre-filter pad Installation, commissioning and LEV test certificate POA Cat. No Description Price Mini 2/4 Cleantec Systems arm option POA 2x50mm Flexible jointed arm, 2x50mm Pen-nib nozzle*, 2xBench clamp bracket, 2x1mtr - 50mm diameter flexible hose, 2x50mm Straight connector, 4x45-60mm Hose clip, 2x100-50mm Reducer, 1xHEPA/carbon filter*, 1xPre-filter pad, EU arm option POA 4x32mm Flexible arm, 4xFlanged hoods*, 4xBench clamp bracket, 4x0.5mtr - 32mm diameter flexible hose, 4x50-32mm Reducers, 4x32mm Hose cuffs, 2x50mm Connectors, 2x1mtr - 50mm diameter flexible hose, 4x45-60mm Hose clip, 1x3mtr - 50mm diameter plastic pipe, 4x50mm 90 bends, 2x50mm Equal tees, 1xHEPA/carbon filter*, 1xPre-filter pad, EU