1 Calypso TRV- (for the Nordic countries) Thermostatic radiator valves With presetting

2 IMI TA / Thermostatic heads and Radiator valves / Calypso TRV- (for the Nordic countries) Calypso TRV- (for the Nordic countries) Thermostatic radiator valve primary for radiators in heating systems and secondary for small cooling terminals. Key features > Stepless presetting Ensures accurate balancing. > Hidden presetting Eliminates the possibility of unauthorized manipulation. > Low flow charateristics Flow range from a very low fl ow up to standard level. > Low noise level Can handle high differential pressure which gives lower risk of noise. > Strong return spring High locating force ensures that the valve does not slacken off over time. > ouble O-rings Trouble free operation. Technical description Applications: Heating and cooling systems Function: Control Stepless presetting Shut-off imensions: N 0-0 Pressure class: PN 0 Max. differential pressure: Maximum differential pressure to ensure that the valve does not open against a closed thermostat: 00 kpa. Temperature: Max. working temperature: 0 C, with protection cap or actuator 00 C. Min. working temperature: -0 C. Materials: Valve body: Brass O-rings: EPM rubber Valve disc: EPM rubber Return spring: Stainless steel Valve insert: Brass, PPS (polyphenylsulphide) Spindle: Niro-steel spindle with double O-ring sealing. Surface treatment: Valve body and fi ttings are nickel-plated Marking: TA, country code, fl ow direction arrow, size and KEYMARK symbol. Red protection cap. Upper part of valve insert: Red Standards: KEYMARK certifi ed and tested according to EN. 0 Connection to thermostatic head: M0x.

3 Construction. Long-life double O-ring sealing.. Strong return spring in combination with high locating force ensures that the valve does not slacken off over time.. Precise regulating part for accurate stepless presetting.. Valve insert replaceable using the fi tting tool without draining the system. Replaceable insert The complete thermostatic insert can be replaced using the fi tting tool (with black handwheel) without draining the system. Noise The following conditions must be fulfi lled in order to avoid noise in the heating system: The maximum recommended pressure drop in order to aviod noise: 0 kpa = 0, bar. Flows correctly balanced The water in the system must have been de-aerated Circulation pumps which do not give too high differential pressure (alternative use a differential pressure controller, e.g. STAP). Setting The valve has stepless presetting which can be adjusted by the presetting tool ( ). The valve is delivered fully open valve (presetting ).. Remove the protective cap.. Set the required value using the presetting tool.. Refi t the protective cap alternatively fi t the thermostat head. *) *) Index

4 IMI TA / Thermostatic heads and Radiator valves / Calypso TRV- (for the Nordic countries) iagram Valve body with thermostatic head P-band [xp].0 K P-band [xp].0 K 0 Kv 0,009/ xp 0, K db(a) 0 db(a) 00 0 Kv 0,009/ xp 0, K db(a) 0 db(a) , 0, 0, 0, Δp [kpa] 0, 0, 0, m [kg/h] Δp [mbar] Δp [kpa] 0, 0, 0, m [kg/h] Δp [mbar] N 0,, 0 Presetting P-band [xp].0k Kv value 0,00 0,0 0,0 0,0 0,0 0, 0,0 0, P-band [xp].0k Kv value 0,00 0,0 0,0 0,09 0, 0,9 0,9 0,0 Kvs 0,00 0,0 0,0 0,09 0, 0, 0,9 0, Permitted differential pressure, during which the valve is kept closed Δp [bar] Th.- head EMO T-TM/NC EMOtec/NC EMO / EMO EIB/LON EMO T/NO EMOtec/NO,0,, Kv/Kvs = m /h at a pressure drop of bar. Flow tolerances

5 Presetting table Presetting values for various radiator performances, pressure drops, and system spread Presetting value at max. K P-band. Q = radiator performance ΔT = system spread Δp = ifferential pressure Example: Q = 000 W, ΔT = K, Δp = 0 kpa Presetting value: Tips: For an approximate determination of the preset for given radiator performance and system spread, an average differential pressure of 0 kpa is recommended. For systems that are widely extended horizontally, a differential pressure drop is necessary: eg, kpa for valves near the central unit, 0 kpa for valves at a medium range, and kpa for valves on remote radiators. An exact determination can only be carried out by making a pipe network calculation using the diagram, or with a calculation program. 0 T

6 N0 N N0 N IMI TA / Thermostatic heads and Radiator valves / Calypso TRV- (for the Nordic countries) Excluding radiator union d l SW* ) H Straight N d l H KvΔTK 0 G/ Mx, 0, 0,00-0, G/ Mx,, 0,00-0, G/ Mx,, 0,00-0, H Angle d SW * ) l I N d l l H KvΔTK 0 G/ Mx, 0,00-0, G/ M,,, 0,00-0, G/ Mx,, 0,00-0, d Reversed angle l SW* ) H N d l H KvΔTK 0 G/ Mx,,0 0,00-0, G/ Mx,, 0,00-0, H d M0x, Angle For replacement of radiator valve in manifold assemblies. N d l H H KvΔTK 0 G/ Mx,, 0,00-0, l H Including radiator union SW* ) SW* ) H Straight d l l N d l l H KvΔTK 0 G/ R/ 0, 0,00-0, G/ R/, 0,00-0, G/ R/ 0, 0,00-0, SW* ) H Angle d SW *) l l I N d l l l H KvΔTK 0 G/ R/ 0,00-0, G/ R/, 0,00-0, G/ R/, 0,00-0, d SW *) SW * ) l l H Reversed angle N d l l H KvΔTK 0 G/ R/,0 0,00-0, G/ R/, 0,00-0, Kv = m /h at Δp = bar. KvΔTK = The values are valid when used together with thermostatic head TRV 00 or TRV Nordic. All valves can be connected to smooth pipes by means of the KOMBI compression coupling. N can also be connected to Alu/PEX pipes by means of the KOMBI-MT compression coupling. - See catalogue leafl ets KOMBI and KOMBI-MT

7 Radiator connections Straight sleeve with nut (Taper connection) For heating and tap water installations N d a L L 0 R/ Mx, R/ Mx, R/ Mx, a d Straight sleeve with O-ring and nut (Taper connection) L N d a L 0 G/ Mx, G/ Mx, G/ Mx, d L H a Elbow with nut (Taper connection) N d a L L H 0 R/ Mx, R/ Mx, Elbow For manifold assemblies (Taper connection) N d a L H 0 Mx, Mx,,

8 IMI TA / Thermostatic heads and Radiator valves / Calypso TRV- (for the Nordic countries) Accessories Pre-setting tool For Calypso TRV-. Colour: Grey KOMBI compression coupling Max.: 00 C (See catalogue leafl et KOMBI.) Male pipe threads on thrust screw For pipes, diameter G/ 90-0 G/ G/ 90-0 G/ G/ G/ 90 - G/ 90 - G/ 90 - G/ 90 - G/ 90 - G/ KOMBI-MT compression coupling Max.: 9 C (See catalogue leafl et KOMBI-MT) Male pipes threads on thrust screw im MT pipe (Alu/PEX) G/ * x 90 - G/ ** x 90 - G/ ** x *) Cone with slot **) Cone without slot Fitting tool complete with case, box spanner and replacement seals, for replacing thermostatic inserts without draining off the heating system (for N 0 to N 0). Fitting tool Replacement seals Measuring spindle for fitting tool for differential pressure measurement at thermostatic valve bodies with TA-SCOPE balancing instrument Spare parts Valve insert Calypso TRV The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifi cations, please visit -- Calypso TRV- v. 0.0