MICROCOR ER DATALOGGER

Size: px
Start display at page:

Download "MICROCOR ER DATALOGGER"

Transcription

1 MICROCOR ER DATALOGGER M-200 The M-200 Microcor Electrical Resistance (ER) Data logger is ideal for use in any process media and remote locations where direct online operation is not possible. With built in technology, stored corrosion rate data may be downloaded from the M-200 from up to 32 ft. (10 m). Without any wires, connectors, or adapters, configuration and download of readings is quicker and easier than ever. Readings from the TU-500 are easily transferred to a PC running Cosasco Data Offline Corrosion Management Software. Cosasco Data Offline provides graphical displays of corrosion data for immediate identification of corrosion upsets. With Cosasco Data Offline Software multiple probes and additional corrosion related parameters can be simultaneously reviewed. Electrical Resistance Metal Loss Measurements in any Process Media Reads all Microcor Corrosion and Erosion Probes Rapid Measurement Cycle Improved resolution Communication Easy data transfer via wireless bluetooth Wireless range up to 32 ft (10m) No more cables required Hazardous Area Location Certified Intrinsically safe ( IECEx/ATEX/ C CSA US ) Certified for use in Class I, Zone 1 NEMA 4X IP66 Rated Enclosure M-200 Shown with a M4700 ER Probe

2 M-200 Specifications Operating Temperature Datalogger: -40 o C to +70 o C (-40 o F to +158 o F) Data Storage Typical Battery Life 16,000 Readings 3 years at 1 Hour Measurement Interval Resolution 18 bit (1 part in 262,144) Weight Enclosure IP 66 Probe Compatibility 6.45 lbs (2.9 kg) Roaming Details: Range: 32 ft. (10m), line of sight Communications: Class v2.0 Applications: FCC/IC/CE Antenna: 2.5 dbi Maximum All Microcor Probes Power Supply 7.2 V Lithium Power Module P/N: Hazardous Area Certifications North America Europe IECEx FM USA FM Canada FM 4.5 dia. by 6.9 high including connectors FM Certification: I/1/A Ex d [i6] IIC/T4 ta= -40 o C to +70 o C, IP66 FM 09 ATEX 0018x IECEX d[i6], Class I, Zone 1, IIC T4, Ta = -40 o C to +70 o C FM IECEx FMG IECEX d[i6], Class I, Zone 1, IIC, T4, Ta = -40 o C to +70 o C 6.38 In. (162 mm) In (294 mm) 4.40 In. (112 mm) 7.59 In. (193 mm)

3 Typical System-High Pressure Transfer Unit Microcor Datalogger Probe Adapter Pressure Retaining Cover Hollow Plug Cosasco Flarweld Access Fitting Microcor Probe Microcor ER Corrosion Monitoring Point: High Pressure (up to 6000 psi) The above diagram shows the equipment required for a typical high pressure corrosion monitoring point using electrical resistance measurement technology. A typical ER Datalogging system consists of an ER probe and probe adapter connected to a hollow plug and inserted into a Cosasco Access Fitting that has been welded onto the pipeline. The ER probe can be installed and retrieved under full operating pressure using a Cosasco Retriever and Service Valve. The TU-500 Transfer Unit communicates wirelessly with the ER-200 to download recorded Corrosion Rate readings. Collected readings on the TU-500 can be downloaded wirelessly to a PC running Cosasco Data off-line Software for graphing and analysis.

4 Transfer Unit (TU-500) Specifications Compatibility -All Cosasco ER and LPR Dataloggers -Microcor ER Datalogger -All legacy ER and LPR Remote Data Collectors and Microcor ER Dataloggers *Excludes RDC 4 Channel -ER and LPR Probe Readers -Ultracorr 2 Reader/Datalogger -Ultracorr Sensors (when used with Ultracorr 2 Reader/Datalogger) Memory Microcor ID s 1-99 and all other ID s Transfer Data Power Source 2 AA Lithium Batteries: P/N Battery Life Display 400,000 data points on 200 series instruments Four Line Liquid Crystal Display (LCD) Temperature Range Operating: -40 o F to 158 o F (-40 o C to 70 o C) Storage: -40 o F to 158 o F (-40 o C to 70 o C) Enclosure Hazardous Area Certifications USA/Canada Europe IECEx IP20 rated enclosure with sealed membrane keypad 6.24 H x 3.35 W x.91 D (15.8 cm x 8.51 cm x 2.31 cm) Range: 32 ft. (10m), line of site Communications: Class v2.0 Approvals: FCC/IC/CE 0539 Antenna: Integrated 2 dbi typical, 4 dbi maximum CSA Canda CSA Certification: CSA US AEx ia IIC T4 Ga, Class 1, Zone 0, Ta= -40 o C to +70 o C CSA USA CSA Ex ia IIC T4 Ga, Class 1, Zone 0, Ta= C -40o C to +20 o C Sira 14 ATEX 2263X Class 1, Zone 0, Ex ia IIC T4, Ga, Ta= -40 o C to +70 o C Sira IECEx SIR x Class 1, Zone 0, Ex ia IIC T4, Ga, Ta= -40 o C to +70 o C 3.35 In. (8.51 cm) 0.91 In. (2.31 cm) 6.24 In. (15.8 cm) 2.87 In. (7.29 cm) 0.88 In. (2.24 cm)

5 Ordering Information M-200 M-200 Electrical Resistance Microcor Datalogger (Includes test probe, batteries, Cosasco Data Offline software, and user manual) Code Enclosure Material 0 Aluminum Enclosure 1 Stainless Steel Enclosure M Example * Maximum cable length is 15 ft. Cables (for Remote Mounting) M-200 Remote Mounting Kit Code Cable Type 0 Cable Assembly Only (Requires Probes Adapter) 1 Retractable (unarmored) 2 Retractable (armored) 3 Retrievable (armored) 2500 PSI 4 Retrievable (unarmored) 2500 PSI 5 Retrievable (armored) 10,000 PSI 6 Retrievable (unarmored) 10,000 PSI Code Cable Length L Length in Feet (15 ft max) Example Probe Adapters Model Part Number M2000 & M3000 Probe Series M4000 & S4000 Probe Series (for permanent connection at 2500 PSI max) (for permanent connection at 10,000 PSI max when used with pressure retaining covers P/N ) Transfer Unit TU Transfer Unit, Batteries, and User Manual Accessories and Replacement Parts Part Number Description Part Number Description TU Transfer Unit Mounting Bracket Assembly for 2 Pipe AA Lithium Battery V Lithium Power Module Microcor Test Probe Installation Kit M-200 Cosasco Smith Avenue Santa Fe Springs, CA 90670, USA Tel: sales@cosasco.com Web Site: Rohrback Cosasco Systems, Inc. All rights reserved The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described wherein or their use or applicability. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Rohrback Cosasco Systems Corrosion Monitoring Equipment is manufactured and sold under one or more of the following US Patents: , , , , , , , , , , , M-200-DS revb Rev. Date 10/04/2016