SITRANS P measuring instruments for pressure

Size: px
Start display at page:

Download "SITRANS P measuring instruments for pressure"

Transcription

1 Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han 7D / Han 8U plug Power supply Supply voltage 30 V AC ( %, Hz, approx. 6 VA) or 4 V AC/DC (4 V AC ± 10%, Hz, approx. 3 VA) Permissible ripple (within the specified Approx..5 V pp limits) Dimensional drawings SITRANS P pressure transmitter with supplementary electronics for 4- wire connection Direct connection of the supplementary electronics to a SITRANS P pressure transmitter from the DS III and DS III PA series produces a transmitter for four-wire connection. The supplementary electronics cannot be attached to explosionprotected pressure transmitters. The supplementary electronics is fitted in a light metal housing which is mounted on the left side of the pressure transmitter. Note on ordering: The supplementary electronics has to be be ordered through the supplementary options of the pressure transmitter in question. Technical specifications SITRANS P, supplementary electronics for 4-wire connection Output Output signal ma or ma Schematics Load Max. 750 Ω Voltage measurement Linear (square-rooting in transmitter if necessary) Terminals Electrical isolation Between power supply and input/ output Measuring accuracy Conformity error (in addition to transmitter) Influence of ambient temperature Power supply effect 0.15% of set span 0.1% per 10 K ( 0.1% per 18 F) 0.1% per 10% change in voltage or frequency 0.1% per 100% change Load effect Rated conditions Ambient temperature C ( F) Storage temperature C ( F) Degree of protection IP54 to EN 6059 Electromagnetic compatibility EN 50081, EN 5008 (EMC) SITRANS P pressure transmitters with supplementary electronics for 4-wire connection, dimension drawing, dimensions in mm (inch) 1 HAN 8U/7D plug plugs AC 30 V UC 4 V I a U H SL 6 7 SL I a - Han 7D Han 7D SL 1 Supplementary electronics for 4-wire connection, connection diagram 3 + I a - U H Han 7D Han 8U I a Output current SL Protective earth conductor U H Power supply U H Siemens FI /105

2 Supplementary electronics for 4-wire connection Selection and Ordering data Supplementary electronics for 4-wire connection of the transmitter 7MF AA. add "-Z" and Power supply Electrical connection 4 V AC/DC Terminals; Pg screwed glands, to left Han 7D/Han 8U plugs incl. mating connector, to left 1 Han 7D plug incl. mating connector, angled Terminals; 1 Pg screwed gland, downwards 1 Han 8U plug incl. mating connector, downwards (observe arrangement of plug and differential pressure line) 30 V AC Terminals; Pg screwed glands, to left Han 7D plugs incl. mating connector, to left Output current 0 to 0 ma 0 4 to 0 ma 1 Order code V Accessories Instruction Manual A5E /106 Siemens FI

3 Selection and Ordering data Replacement measuring cell for pressure for SITRANS P, bar ( psi) B bar ( psi) C bar ( psi) D bar ( psi) E bar ( psi) F bar ( psi) G Seal diaphragm Hastelloy Stainless steel B Hastelloy Hastelloy C Connection shank G½B to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel, max. span 160 bar (30 psi) - Mounting thread M10 to DIN Please add "-Z" to and specify MKII, MS, 7 M F D C 0 Selection and Ordering data Replacement measuring cell for absolute pressure (from the pressure series) for SITRANS P, 7 M F D C mbar ( psi) E) D mbar ( psi) E) F bar ( psi) E) G bar ( psi) H Seal diaphragm Hastelloy Stainless steel E) B Hastelloy Hastelloy E) C Connection shank G½B to EN Female thread ½-14 NPT 1 Oval flange made of stainless steel, max. span 160 bar (30 psi) - Mounting thread M10 to DIN Please add "-Z" to and specify E) Combinations of the versions marked with E) are subject to the export regulations AL: B30, ECCN: N. Siemens FI /107

4 MKII, MS, Replacement measuring cell for absolute pressure (from the differential pressure series) for SITRANS P, 7 M F mbar ( psi) E) D mbar ( psi) E) F bar ( psi) E) G bar ( psi) H bar ( psi) K E Hastelloy Stainless steel E) B Hastelloy Hastelloy E) C Tantalum Tantalum E Monel Monel E) H Gold Gold L Female thread ¼-18 NPT with flange connection - Mounting thread M10 to DIN Vent on side of process flange 1) - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Stainless steel process flange screws Please add "-Z" to and specify G½A D16 Remote seal flanges D0 (not together with K01, K0 and K04) Vent on side for gas measurements H0 Process flanges without with process flange made of - Hastelloy K01 - Monel K0 - Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi) max. temperature of medium 90 C (194 F) 1) Not for span " bar ( psi)" E) Combinations of the versions marked with E) are subject to the export regulations AL: B30, ECCN: N. Replacement measuring cell for differential pressure and PN 3/160 (MWP 464/30 psi) for SITRANS P, 7 M F PN 3 (MWP 464 psi) mbar 1) ( psi) B PN 160 (MWP 30 psi) mbar ( psi) C mbar ( psi) D mbar ( psi) E mbar ( psi) F mbar ( psi) G bar ( psi) H (stainless steel process flanges) Hastelloy Stainless steel B Hastelloy Hastelloy C Tantalum ) Tantalum E Monel ) Monel H Gold ) Gold L Female thread ¼-18 NPT with flange connection - Mounting thread M10 to DIN Vent on side of process flange - Mounting thread M10 to DIN Mounting thread 7 / 16-0 UNF to EN Stainless steel process flange screws Please add "-Z" to and specify Remote seal flanges D0 (not together with K01, K0 and K04) Vent on side for gas measurements H0 Stainless steel process flanges for vertical H03 differential pressure lines (not together with K01, K0 and K04) Process flanges without with process flange made of -Hastelloy K01 - Monel K0 - Stainless steel with PVDF insert K04 max. PN 10 (MWP 145 psi) max. temperature of medium 90 C (194 F) 1) Not suitable for connection of remote seal ) Only together with max. spans 50, 1600, 5000 and mbar (3.63, 3., 7.5 and 435 psi). /108 Siemens FI

5 Replacement measuring cell for differential pressure and PN 40 (MWP 609 psi) for SIT- RANS P, DS III, DS III PA and DS III FF series mbar ( psi) D mbar ( psi) E mbar ( psi) F mbar ( psi) G bar ( psi) H (stainless steel process flanges) Hastelloy Stainless steel B Gold 1) Gold L Female thread ¼-18 NPT with flange connection - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN Vent on side of process flange - Mounting thread M1 to DIN Mounting thread 7 / 16-0 UNF to EN MKII, MS, 7 M F Stainless steel process flange screws Please add "-Z" to and specify Order code. Stainless steel process flanges for vertical differential pressure lines H03 without process flanges Replacement measuring cell for level for SITRANS P, DS III, DS III PA and DS III FF series 7 M F Rated measuring range 50 mbar (3.63 psi) D 600 mbar (8.70 psi) E 1600 mbar (3. psi) F 5 bar (7.5 psi) G (stainless steel process flanges) of low-pressure side Female thread ¼-18 NPT with flange connection - Mounting thread M10 to DIN Stainless steel process flange screws Please add "-Z" to and specify Order code. to EN B without process flanges 1) Not together with max. span 600 mbar Siemens FI /109

6 MKII, MS, for pressure transmitters MKII series (7MF C.) MS series (7MF C.) (7MF C.) for absolute pressure transmitters (7MF C.) 7MF4997-1AB 7MF4997-1AH for pressure transmitters MKII series (7MF A., -1.B. and -1.D.) MS series (7MF A., -1.B. and -1.D.) (7MF A., -..B. and -..D.) for absolute pressure transmitters (7MF A., -..B. and -..D.) Made of steel 7MF4997-1AC Made of stainless steel } 7MF4997-1AJ for differential pressure transmitters with flange thread M10 (7MF and 7MF ) 7MF4997-1AD } 7MF4997-1AK for differential pressure transmitters with flange thread M1 (7MF ) 7MF4997-1AE 7MF4997-1AL for differential and absolute pressure transmitters with flange thread 7/16-0 UNF (7MF , 7MF and 7MF ) 7MF4997-1AF 7MF4997-1AM Cover Made of die-cast aluminium, including gasket, for MK II, MS, DS III, DS III PA and DS III FF series without window 7MF4997-1BB with window } 7MF4997-1BE Cover Made of stainless steel, including gasket, for without window 7MF4997-1BC with window 7MF4997-1BF Analog indicator Scale % 7MF4997-1BN Customer-specific scale divisions as specified 7MF4997-1BP-Z in plain text Y0:... Digital indicator Including mounting material 7MF4997-1BR for MS, Measuring-point label without inscription (5 off) 7MF4997-1CA with inscription (1 off) Data according to Y01 or Y0, Y15 and Y16 (see "SITRANS P pressure transmitters") Mounting screws for measuring-point label, earthing and connection terminals or for digital indicator (50 off) 7MF4997-1CB-Z Y..:... 7MF4997-1CD Sealing screws (1 set = off) for process flange 7MF4997-1CG made of Hastelloy 7MF4997-1CH Vent valves complete (1 set = off) } 7MF4997-1CP made of Hastelloy 7MF4997-1CQ Electronics for DS III series 7MF4997-1DK for DS III PA series 7MF4997-1DL for DS III FF series 7MF4997-1DM Connection board for DS III series 7MF4997-1DN for DS III PA and DS III FF series 7MF4997-1DP made of FPM (Viton) 7MF4997-DA 7MF4997-DB FEP (with silicone core, approved for food) 7MF4997-DC 7MF4997-DD 7MF4997-DE Instruction Manual 1) for MK II series - German, English C73000-B5674-C100 - French, Spanish, Italian C73000-B5650-C100 for MS series - German, English C73000-B5674-C40 - French, Spanish, Italian C73000-B5650-C40 for DS III series -German A5E English A5E French A5E Spanish A5E Italian A5E for DS III PA series -German A5E English A5E French A5E Spanish A5E Italian A5E for DS III FF series -German A5E English (planned) A5E French (planned) A5E Spanish (planned) A5E Italian (planned) A5E Brief instructions (Leporello) for MS series, German, English C79000-X5674-C41 for DS III series, German, English A5E for DS III PA series, German, English A5E for DS III FF series, German, English A5E CD with documentation A5E for MK II, MS, German, English, French, Italian, Spanish Instruction Manual for replacement of electronics, measuring cell and connection board German/English A5E HART communication HART modem } 7MF4997-1DA D) Supplementary electronics for 4-wire connection see page /106 } Available ex stock Power supply units see "SITRANS I power supply units and input isolators". 1) You can download the Instruction Manuals free-of-charge from the Internet site D) Subject to export regulations AL: N, ECCN: EAR99H. /110 Siemens FI