Test Report. No. TSNEC Date: 22 Nov Page 1 of 8.

Size: px
Start display at page:

Download "Test Report. No. TSNEC Date: 22 Nov Page 1 of 8."

Transcription

1 Test Report. No. TSNEC Date: 22 Nov Page 1 of 8. BEIJING DOUBLINK SOLDERS CO.,LTD. NO.40 BEIYUAN ROAD,CHAOYANG DISTRICT,BEIJING,CHINA.. The following sample(s) was/were submitted and identified on behalf of the clients as : COPPER WIRE. SGS Job No. : TP TJ. Main Substance :. COPPER(Cu). Model No. :. HC2. Client Ref. Info. :. Other Model No.:HC1-n. Date of Sample Received :. 19 Nov Testing Period :. 19 Nov Nov Test Requested :. Test Method :. Selected test(s) as requested by client.. Please refer to next page(s).. Test Results :. Conclusion :. Please refer to next page(s).. Based on the performed tests on submitted sample(s), the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP), and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.. Signed for and on behalf of SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd.. Reabeca Zhou. Approved Signatory.

2 Test Report. No. TSNEC Date: 22 Nov Page 2 of 8. Test Results :. Test Part Description :. Specimen No.. SGS Sample ID. Description. SN1. TSN coppery metal wire. Remarks :. (1) 1 mg/kg = %. (2) MDL = Method Detection Limit. (3) ND = Not Detected ( < MDL ). (4) "-" = Not Regulated. RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method :. With reference to IEC :2013, IEC :2013+AMD1:2017, IEC :2015, IEC :2015 and IEC :2017, analyzed by ICP-OES, UV-Vis and GC-MS.. Test Item(s). Limit. Unit. MDL Cadmium (Cd). 100 mg/kg. 2 ND Lead (Pb) mg/kg. 2 ND Mercury (Hg) mg/kg. 2 ND Hexavalent Chromium (Cr(VI)). -. µg/cm² ND Sum of PBBs mg/kg. - ND Monobromobiphenyl. - mg/kg. 5 ND Dibromobiphenyl. - mg/kg. 5 ND Tribromobiphenyl. - mg/kg. 5 ND Tetrabromobiphenyl. - mg/kg. 5 ND Pentabromobiphenyl. - mg/kg. 5 ND Hexabromobiphenyl. - mg/kg. 5 ND Heptabromobiphenyl. - mg/kg. 5 ND Octabromobiphenyl. - mg/kg. 5 ND Nonabromobiphenyl. - mg/kg. 5 ND Decabromobiphenyl. - mg/kg. 5 ND Sum of PBDEs mg/kg. - ND Monobromodiphenyl ether. - mg/kg. 5 ND Dibromodiphenyl ether. - mg/kg. 5 ND Tribromodiphenyl ether. - mg/kg. 5 ND Tetrabromodiphenyl ether. - mg/kg. 5 ND

3 Test Report. No. TSNEC Date: 22 Nov Page 3 of 8. Test Item(s). Limit. Unit. MDL Pentabromodiphenyl ether. - mg/kg. 5 ND Hexabromodiphenyl ether. - mg/kg. 5 ND Heptabromodiphenyl ether. - mg/kg. 5 ND Octabromodiphenyl ether. - mg/kg. 5 ND Nonabromodiphenyl ether. - mg/kg. 5 ND Decabromodiphenyl ether. - mg/kg. 5 ND Dibutyl phthalate (DBP) mg/kg. 50 ND Butyl benzyl phthalate (BBP) mg/kg. 50 ND Bis (2-ethylhexyl) phthalate (DEHP) mg/kg. 50 ND Diisobutyl Phthalates (DIBP) mg/kg. 50 ND Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. IEC series is equivalent to EN series ,25 (2) = a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm². The sample coating is considered to contain CrVI b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm²). The coating is considered a non-crvi based coating c. The result between 0.10 μg/cm² and 0.13 μg/cm² is considered to be inconclusive - unavoidable coating variations may influence the determination Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI) results represent status of the sample at the time of testing. (3) On 4 June 2015, Commission Directive (EU) 2015/863 was published in the Official Journal of the European Union (OJEU) to include the phthalates BBP, DBP, DEHP and DIBP into ANNEX II of the Rohs Recast Directive. The new law restricts each phthalate to no more than 0.1% in each homogeneous material of an electrical product. (4) The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, from 22 July (5) The restriction of DEHP, BBP, DBP and DIBP shall not apply to cables or spare parts for the repair, the reuse, the updating of functionalities or upgrading of capacity of EEE placed on the market before 22 July 2019, and of medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, placed on the market before 22 July (6) The restriction of DEHP, BBP and DBP shall not apply to toys which are already subject to the restriction of DEHP, BBP and DBP through entry 51 of Annex XVII to Regulation (EC) No 1907/ Halogen.

4 Test Report. No. TSNEC Date: 22 Nov Page 4 of 8. Test Method :. With reference to EN 14582: 2016, analysis was performed by Ion Chromatograph (IC).. Test Item(s). Unit. MDL Fluorine (F). mg/kg. 50 ND Chlorine (Cl). mg/kg. 50 ND Bromine (Br). mg/kg. 50 ND Iodine (I). mg/kg. 50 ND Perfluorooctane Sulfonates (PFOS) and Perfluorooctanoic Acid (PFOA). Test Method :. With reference to CEN/TS 15968:2010, analysis was performed by LC-MS.. Test Item(s). Limit. Unit. MDL Perfluorooctane Sulfonates (PFOS)^. 10 mg/kg. 10 ND Perfluorooctanoic Acid (PFOA). - mg/kg. 10 ND Notes :. (1) Max. limit specified by commission regulation (EU) No. 757/2010 amending Regulation (EC) No 850/2004 (previously restricted under entry 53 of Regulation (EC) No 552/2009 amending Annex XVII of REACH Regulation (EC) No 1907/2006). (2) ^: PFOS refer to Perfluorooctanesulfonic acid and its derivatives including Perfluoroctanesulfonic acid, Perfluoroctane sulfonamide, N-Methylperfluoroctane sulfonamide, N-Ethylperfluoroctane sulfonamide, N-Methylperfluoroctane sulfonamidoethanol and N-Ethylperfluoroctane sulfonamidoethanol..

5 Test Report. No. TSNEC Date: 22 Nov Page 5 of 8. ATTACHMENTS Pb/Cd/Hg/Cr 6+ /PBBs/PBDEs/Phthalates Testing Flow Chart 1) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr 6+ and PBBs/PBDEs /Phthalates test method excluded) Sample Preparation Sample Measurement Pb/Cd/Hg PBBs/PBDEs/Phthalates Cr 6+ Acid digestion with microwave / hotplate Solution Filtration Residue 1) Alkali Fusion / Dry Ashing 2) Acid to dissolve Sample solvent extraction Concentration/ Dilution of extraction solution Filtration GC-MS ABS/PC/PVC Dissolving by ultrasonication Digesting at 60 C by ultrasonication Nonmetallic material Others ph adjustment Digesting at 150~160 C Separating to get aqueous phase Metallic material Boiling water extraction Adding 1,5- diphenylcarba zide for color development UV-Vis. ICP-OES/AAS Adding 1,5- diphenylcarbazide for color development UV-Vis

6 Test Report. No. TSNEC Date: 22 Nov Page 6 of 8. ATTACHMENTS Halogen Testing Flow Chart Sample cutting/preparation Sample measurement Combustion in oxygen bomb Dissolved in an absorption solution Filtration Analyzed by ion chromatography. Double confirm by other instruments, if necessary

7 Test Report. No. TSNEC Date: 22 Nov Page 7 of 8. ATTACHMENTS PFOS/PFOA Testing Flow Chart Sample cutting/preparation Sample measurement Solvent extraction Concentration/Dilution Filtration LC-MS

8 Test Report. No. TSNEC Date: 22 Nov Page 8 of 8. Sample photo:. TSNEC TSN SGS authenticate the photo on original report only. *** End of Report ***.