The following sample(s) was/were submitted and identified on behalf of the clients as : TO. Please refer to next page(s)..

Size: px
Start display at page:

Download "The following sample(s) was/were submitted and identified on behalf of the clients as : TO. Please refer to next page(s).."

Transcription

1 Test Report. No. Date: 27 Feb Page 1 of 11. RIZHAO XURI ELECTRONICS CO.,LTD. NO.388 OF DALIAN ROAD DEVELOPMENT DISTRICT RIZHAO,SHANDONG CHINA.. The following sample(s) was/were submitted and identified on behalf of the clients as : TO. SGS Job No. : TP TJ. Model No. :. TO Client Ref. Info. :. Other Model No.:See Attachment. Date of Sample Received :. 22 Feb Testing Period :. 22 Feb Feb Test Requested :. Selected test(s) as requested by client.. Test Method :. Please refer to next page(s).. Test Results :. Please refer to next page(s).. Conclusion :. Based on the performed tests on submitted sample(s)(001,002), the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP), and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.. Based on the performed tests on submitted sample(s)( ), the results of Lead, Mercury, Cadmium, Hexavalent chromium comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.. Signed for and on behalf of SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd.. Reabeca Zhou. Approved Signatory.

2 Test Report. No. Date: 27 Feb Page 2 of 11. Test Results :. Test Part Description :. Specimen No.. SGS Sample ID. Description. SN1. TSN black solid. SN2. TSN brown solid. SN3. TSN silver gray metal. SN4. TSN silver gray metal. SN5. TSN silver gray metal pin. SN6. TSN gold metal pin. Remarks :. (1) 1 mg/kg = %. (2) MDL = Method Detection Limit. (3) ND = Not Detected ( < MDL ). (4) "-" = Not Regulated. RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method :. With reference to IEC :2013, IEC :2013+A1:2017, IEC :2017, IEC :2015 and IEC :2017, analyzed by ICP-OES, UV-Vis and GC-MS.. Test Item(s). Limit. Unit. MDL Cadmium (Cd). 100 mg/kg. 2 ND ND Lead (Pb) mg/kg. 2 ND ND Mercury (Hg) mg/kg. 2 ND ND Hexavalent Chromium (Cr(VI)) mg/kg. 8 ND ND Sum of PBBs mg/kg. - ND ND Monobromobiphenyl. - mg/kg. 5 ND ND Dibromobiphenyl. - mg/kg. 5 ND ND Tribromobiphenyl. - mg/kg. 5 ND ND Tetrabromobiphenyl. - mg/kg. 5 ND ND Pentabromobiphenyl. - mg/kg. 5 ND ND Hexabromobiphenyl. - mg/kg. 5 ND ND Heptabromobiphenyl. - mg/kg. 5 ND ND Octabromobiphenyl. - mg/kg. 5 ND ND Nonabromobiphenyl. - mg/kg. 5 ND ND Decabromobiphenyl. - mg/kg. 5 ND ND

3 Test Report. No. Date: 27 Feb Page 3 of 11. Test Item(s). Limit. Unit. MDL Sum of PBDEs mg/kg. - ND ND Monobromodiphenyl ether. - mg/kg. 5 ND ND Dibromodiphenyl ether. - mg/kg. 5 ND ND Tribromodiphenyl ether. - mg/kg. 5 ND ND Tetrabromodiphenyl ether. - mg/kg. 5 ND ND Pentabromodiphenyl ether. - mg/kg. 5 ND ND Hexabromodiphenyl ether. - mg/kg. 5 ND ND Heptabromodiphenyl ether. - mg/kg. 5 ND ND Octabromodiphenyl ether. - mg/kg. 5 ND ND Nonabromodiphenyl ether. - mg/kg. 5 ND ND Decabromodiphenyl ether. - mg/kg. 5 ND ND Dibutyl phthalate (DBP) mg/kg. 50 ND ND Butyl benzyl phthalate (BBP) mg/kg. 50 ND ND Bis (2-ethylhexyl) phthalate (DEHP) mg/kg. 50 ND ND Diisobutyl Phthalates (DIBP) mg/kg. 50 ND ND Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. IEC series is equivalent to EN series ,25 (2) On 4 June 2015, Commission Directive (EU) 2015/863 was published in the Official Journal of the European Union (OJEU) to include the phthalates BBP, DBP, DEHP and DIBP into ANNEX II of the Rohs Recast Directive. The new law restricts each phthalate to no more than 0.1% in each homogeneous material of an electrical product. (3) The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, from 22 July (4) The restriction of DEHP, BBP, DBP and DIBP shall not apply to cables or spare parts for the repair, the reuse, the updating of functionalities or upgrading of capacity of EEE placed on the market before 22 July 2019, and of medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, placed on the market before 22 July (5) The restriction of DEHP, BBP and DBP shall not apply to toys which are already subject to the restriction of DEHP, BBP and DBP through entry 51 of Annex XVII to Regulation (EC) No 1907/ RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method :. With reference to IEC :2013, IEC :2013+A1:2017, IEC :2015, analyzed by ICP-OES and UV-Vis..

4 Test Report. No. Date: 27 Feb Page 4 of 11. Test Item(s). Limit. Unit. MDL Cadmium (Cd). 100 mg/kg. 2 ND ND ND Lead (Pb) mg/kg. 2 ND ND ND Mercury (Hg) mg/kg. 2 ND ND ND Hexavalent Chromium (Cr(VI)). -. µg/cm² ND ND ND Test Item(s). Limit. Unit. MDL Cadmium (Cd). 100 mg/kg. 2 ND Lead (Pb) mg/kg. 2 ND Mercury (Hg) mg/kg. 2 ND Hexavalent Chromium (Cr(VI)). -. µg/cm² ND Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. IEC series is equivalent to EN series ,25 (2) = a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm². The sample coating is considered to contain CrVI b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm²). The coating is considered a non-crvi based coating c. The result between 0.10 μg/cm² and 0.13 μg/cm² is considered to be inconclusive - unavoidable coating variations may influence the determination Information on storage conditions and production date of the tested sample is unavailable and thus Cr(VI) results represent status of the sample at the time of testing..

5 Test Report. No. Date: 27 Feb Page 5 of 11. Attachment PMGI0190 TO-5-2P3LB TO39 4L PMGI0126 TO18(2+1) TO39(2+1) 2.5T PMGI0111 TO TO T PMGI0108 TO TO outer dimeter5.8 PMGI0198 TO18-1.1T TO46-(1+1)-45 PMGI0201 TO18(3+1)Au TO46(4+1) PMGI0202 TO18(1+1)-nail TO46(2+1) PMGI0147 TO18 GSB (1+1) 2.0T TO NC-23-Au TO18(1+1)38.5 TO NC-21-Au TO18(2+1) Au TO46(4+1) with tail NC-4-Ni TO18 2.5T 2+1 TO conjoined NC-4-Au TO-18GMK3 TO conjoined NC-22 TO-18GMK TO46C NC-24(Ni)-R TO-18GSB TO46S NC-21-Ni TO18 GSB-27.0 TO with cross mark NC-4(AU)-20.0-R TO18-(1+1)45 TO NC-25(Au)-R TO T 1110 TO TO inner lead 1.85 TO T TO TO inner lead 2.0 TO39(2+1) TO TO TO39(1+1)Au T TO TO39 M10030 TO TO TO39(5+1) TO72 TO TO39(4+1) KLD-2160X-1.0T TO TO39-4C inner lead 0.5 KLD-3.0 TO-5(5+1) TO KLD-2.0

6 Test Report. No. Date: 27 Feb Page 6 of 11. ATTACHMENTS Pb/Cd/Hg/Cr 6+ /PBBs/PBDEs/Phthalates Testing Flow Chart 1) Name of the person who made testing: Cathy Zhang/Crystal Wang/Ann Wang/Cyhan Chen 2) Name of the person in charge of testing: Aaron Wang/Rex Zhu 3) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr 6+ and PBBs/PBDEs /Phthalates test method excluded) Sample Preparation Sample Measurement Pb/Cd/Hg PBBs/PBDEs/Phthalates Cr 6+ Acid digestion with microwave / hotplate Solution Filtration Residue 1) Alkali Fusion / Dry Ashing 2) Acid to dissolve Sample solvent extraction Concentration/ Dilution of extraction solution Filtration GC-MS ABS/PC/PVC Dissolving by ultrasonication Digesting at 60 C by ultrasonication Nonmetallic material Others ph adjustment Digesting at 150~160 C Separating to get aqueous phase Metallic material Boiling water extraction Adding 1,5- diphenylcarba zide for color development UV-Vis. ICP-OES/AAS Adding 1,5- diphenylcarbazide for color development UV-Vis

7 Test Report. No. Date: 27 Feb Page 7 of 11. ATTACHMENTS Pb/Cd/Hg/Cr 6+ Testing Flow Chart 1) Name of the person who made testing: Cathy Zhang/Crystal Wang 2) Name of the person in charge of testing: Aaron Wang 3) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr 6+ test method excluded) Sample Preparation Sample Measurement Pb/Cd/Hg Cr 6+ Acid digestion with microwave / hotplate Solution Filtration ICP-OES/AAS Residue 1) Alkali Fusion / Dry Ashing 2) Acid to dissolve ABS/PC/PVC Dissolving by ultrasonication Digesting at 60 C by ultrasonication Nonmetallic material Others ph adjustment Digesting at 150~160 C Separating to get aqueous phase Adding 1,5- diphenylcarbazide for color development Metallic material Boiling water extraction Adding 1,5- diphenylcarba zide for color development UV-Vis. UV-Vis

8 Test Report. No. Date: 27 Feb Page 8 of 11. Sample photo:. TSN TSN

9 Test Report. No. Date: 27 Feb Page 9 of 11. TSN TSN

10 Test Report. No. Date: 27 Feb Page 10 of 11. TSN TSN

11 Test Report. No. Date: 27 Feb Page 11 of SGS authenticate the photo on original report only. *** End of Report ***.