Test Report. No. SZARR Date: Aug. 16, 2017 Page 1 of 14

Size: px
Start display at page:

Download "Test Report. No. SZARR Date: Aug. 16, 2017 Page 1 of 14"

Transcription

1 No. SZARR Date: Aug. 16, 2017 Page 1 of 14 Applicant : Shanghai MXCHIP Information Technology Co.,Ltd Address : 9th Floor, No.5, Lane 2145 JinshaJiang Road, Putuo District, Shanghai The submitted sample and sample information was/were submitted and identified by/on the behalf of the client Sample name : EMG5062(EMG5062-PLUG/EMG5062-ESIM) Manufacturer : Shanghai MXCHIP Information Technology Co.,Ltd Country of Destination : Europe, U.S.A, Other Country of Origin : China Sample received date : Aug. 09, 2018 Testing period : Aug. 09, 2018 to Aug. 16, 2018 Test requested : 1. As specified by client, to screen Lead(Pb), Cadmium(Cd), Mercury(Hg), Chromium(Cr) and Bromine(Br) in the submitted sample(s) by XRF. 2. As specified by client, when screening results exceed the XRF screening limit in IEC :2013, further use of chemical methods are required to test the Lead(Pb), Cadmium(Cd), Mercury(Hg), Hexavalent Chromium(Cr(VI)), Polybrominated Biphenyls(PBBs), Polybrominated Diphenyl Ethers(PBDEs) in the submitted samples in accordance with the RoHS Directive 2011/65/EU. 3. As specified by client, to test the Dibutyl phthalate(dbp), Di-2-ethylhexyl phthalate(dehp), Di-isobutyl phthalate(dibp), Benzyl butyl phthalate(bbp) in the submitted sample in accordance with the RoHS Directive 2011/65/EU and amendment Commission Delegated Directive (EU) 2015/863 with effective from 22 July Test Method: Please refer to the following page(s). Test Result(s): Please refer to the following page(s). Tested by Reviewed by Approved by Liqing Yang Niki You Leo Li Test engineer Test engineer Authorized signatory

2 No. SZARR Date: Aug. 16, 2017 Page 2 of 14 Test Method: A. Screening test by XRF spectroscopy XRF screening limits in mg/kg for regulated elements according to IEC :2013. Limit of IEC :2013. Unit (mg/kg) MDL Element Other Polymers and metals Composite material Polymers material Pb BL (700-3σ) <X <(1300+3σ) BL (500-3σ)<X <(1500+3σ) OL OL 10 mg/kg 50 mg/kg Cd BL (70-3σ)<X <(130+3σ) LOD (50-3σ)<X <(150+3σ) OL OL 10 mg/kg 50 mg/kg Hg BL (700-3σ)<X <(1300+3σ) BL (500-3σ)<X <(1500+3σ) OL OL 10 mg/kg 50 mg/kg Cr BL (700-3σ)< X BL (500-3σ)< X 10 mg/kg 50 mg/kg Br BL (300-3σ)< X BL (250-3σ)< X 10 mg/kg 50 mg/kg Note: -BL = Under the XRF screening limit -OL = Further chemical test will be conducted while result is above the screening limit -X= The symbol X marks the region where further investigation is necessary -3σ= The reproducibility of analytical instruments -LOD= Detection limit B. Chemical Test Test Item(s) Test Method Measured Equipment(s) MDL Limit Lead (Pb) IEC :2013 Ed.1.0 ICP-OES 2 mg/kg 1000 mg/kg Cadmium (Cd) IEC :2013 Ed.1.0 ICP-OES 2 mg/kg 100 mg/kg Mercury (Hg) IEC :2013+AMD1:2017 ICP-OES 2 mg/kg 1000 mg/kg IEC :2015 Ed.1.0 UV-VIS / 1000 mg/kg Hexavalent Chromium Cr(VI) IEC :2017 Ed.1.0 UV-VIS 2 mg/kg 1000 mg/kg Polybrominated Biphenyls (PBBs) IEC :2015 Ed.1.0 GC-MS 5 mg/kg 1000 mg/kg Polybrominated Diphenyl Ethers (PBDEs) IEC :2015 Ed.1.0 GC-MS 5 mg/kg 1000 mg/kg Phthalates IEC :2017 Ed.1.0 GC-MS 50 mg/kg 1000 mg/kg

3 No. SZARR Date: Aug. 16, 2017 Page 3 of 14 Test Results: Sample Sample No. Description 1 Soldering tin 2 Blue PCB 3 Chip resistor 4 IC 5 Black inductor 6 IC Tested Items XRF Screening Test Chemical Test Unit (mg/kg) Unit (mg/kg) Br(PBBs&PBDEs) X N.D. Conclusion

4 No. SZARR Date: Aug. 16, 2017 Page 4 of 14 Sample Sample No. Description 7 White LED 8 Chip capacitor 9 Green PCB 10 Crystal oscillator Coppery metal 11 contact plate Black 12 component Tested Items XRF Screening Test Chemical Test Unit (mg/kg) Unit (mg/kg) Br(PBBs&PBDEs) X N.D. Conclusion

5 No. SZARR Date: Aug. 16, 2017 Page 5 of 14 Sample No. Sample Description 13 Green PCB 14 Yellow component 15 Chip resistor 16 Chip diode 17 Chip audion 18 Yellow capacitor Tested Items XRF Screening Test Chemical Test Unit (mg/kg) Unit (mg/kg) Br(PBBs&PBDEs) X N.D. Conclusion

6 No. SZARR Date: Aug. 16, 2017 Page 6 of 14 Sample No. Sample Description 19 Crystal oscillator 20 Silvery metal plate 21 Black inner plastic 22 Pin 23 White label 24 Silvery metal plate Tested Items XRF Screening Test Chemical Test Unit (mg/kg) Unit (mg/kg) Cr(Cr(VI) ) X Negative Conclusion

7 No. SZARR Date: Aug. 16, 2017 Page 7 of 14 Sample No. Sample Description 25 Pin 26 White plastic terminal Tested Items XRF Screening Test Chemical Test Unit (mg/kg) Unit (mg/kg) Conclusion Test Result(s): Tested Item(s) Di-isobutyl phthalate(dibp) CAS #: Dibutyl phthalate(dbp) CAS #: Benzylbutyl phthalate(bbp) CAS #: Di-2-ethylhexyl phthalate(dehp) CAS #: Result Unit (mg/kg)

8 No. SZARR Date: Aug. 16, 2017 Page 8 of 14 Tested Item(s) Di-isobutyl phthalate(dibp) CAS #: Dibutyl phthalate(dbp) CAS #: Benzylbutyl phthalate(bbp) CAS #: Di-2-ethylhexyl phthalate(dehp) CAS #: Result Unit (mg/kg) Tested Item(s) Di-isobutyl phthalate(dibp) CAS #: Dibutyl phthalate(dbp) CAS #: Benzylbutyl phthalate(bbp) CAS #: Di-2-ethylhexyl phthalate(dehp) CAS #: Result Unit (mg/kg) N.D. N.D. N.D. N.D. 255 N.D. Note: - The screening results are only used for reference. - When conducting the test for PBBs&PBDEs, XRF was introduced to screen Br Exclusively; When conducting the test for Hexavalent Chromium, XRF was introduced to screen Chromium exclusively. -MDL = Method Detection Limit -N.D. = Not Detected (<MDL) -mg/kg = ppm = parts per million -Negative = Absence of Cr(VI), the detected Cr(VI) concentration in the boiling water extraction solution is less than 0.10ug/cm 2. -Positive = Presence of Cr(VI), the detected Cr(VI) concentration in the boiling water extraction solution is equal to or greater than 0.13ug/cm 2.

9 No. SZARR Date: Aug. 16, 2017 Page 9 of 14 Test Process: The sample(s) had been dissolved totally tested for Lead, Cadmium, Mercury. IEC :2013 Ed.1.0 Pb/Cd Weigh the sample into a vessel Add digestion reagent Digest the sample Dry Ashing/ Alkali Fusion/ Residue Analyzed by ICP-OES Make up with deionized water Acid Dissolution Solution Filtration IEC :2013+AMD1:2017 Hg Weigh sample and place it in a microwave digestion vessel Add digestion reagent Digest sample in microwave digestion oven Analyzed by ICP-OES Make up with deionized water Alkali Fusion/ Acid Dissolution Solution Residue Filtration IEC :2015 Ed.1.0 Cr(VI) Take a portion of the sample Extracted with boiling water Filter and remove the sample Analyzed by UV-Vis Add test solution Adjust the ph value of the solution

10 No. SZARR Date: Aug. 16, 2017 Page 10 of 14 IEC :2017 Ed.1.0 Cr(VI) Weigh sample and place it in a conical flask Add digestion reagent Heat at for 3 hours Adjust the ph value of the solution Add test solution Adjust the ph value of the solution Cool and filter Make up with deionized water Analyzed by UV-Vis IEC :2015 Ed.1.0 PBBs/ PBDEs Weigh sample and place it in a thimble Extracted with organic solvent Concentrate the extract Analyzed by GC-MS Make up with organic solvent Transfer the extract into a volumetric flask IEC :2017 Ed.1.0 Phthalate Weigh sample and place it in a thimble Extracted with organic solvent Concentrate the extract Analyzed by GC-MS Make up with organic solvent Transfer the extract into a volumetric flask

11 No. SZARR Date: Aug. 16, 2017 Page 11 of 14 Photograph of Sample SZARR Photo(s) of the tested component(s)

12 No. SZARR Date: Aug. 16, 2017 Page 12 of

13 No. SZARR Date: Aug. 16, 2017 Page 13 of

14 No. SZARR Date: Aug. 16, 2017 Page 14 of ***** End of Report ***** The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer only to the sample(s) tested. Without written approval of Anbotek, this report can t be reproduced except in full.