LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Size: px
Start display at page:

Download "LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO."

Transcription

1 Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from cmh O up to mh O Output signals -wire: ma -wire: 0 0 V others on request Special characteristics diameter 9.5 mm especially for sewage, viscous and pasty media Optional versions IS-protection zone 0 mounting with stainless steel pipe diaphragm 99.9 % AI O different kinds of cables different kinds of elastomers The stainless steel probe LMK 8 has been designed for continous level measurement in waste water, waste and higher viscosity media. Basic element is a robust and high overpressure capable capacitive ceramic sensor e.g. for low levels easily. Preferred areas of use are Water drinking water abstraction Sewage waste water treatment water recycling Fuel / Oil level monitoring in open tanks with low filling heights fuel storage tank farms / biogas plants

2 Input pressure range Nominal pressure gauge [bar] Level [mh O] Overpressure [bar] Output signal / Supply Standard Option IS-protection -wire: ma / V S = 9... V DC -wire: ma / V S = V DC Option -wire -wire: V / V S =.5... V DC Performance Accuracy standard: ± 0.5 % FSO option: ± 0.5 % FSO Permissible load R max = [(V S V S min ) / 0.0 A] Ω Influence effects supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Turn-on time 700 msec Mean response time < 00 msec measuring rate 5/sec Max. response time 80 msec accuracy according to IEC limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Thermal error ± 0. % FSO / 0 K in compensated range C Permissible temperatures Permissible temperatures medium: C electronics / environment: C storage: C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection (only for 4 0 ma / -wire) Cable with sheath material PVC (-5 70 C) grey PUR (-5 70 C) black FEP 4 (-5 70 C) black TPE (-5 5 C) blue shielded cable with integrated air tube for atmospheric pressure reference 4 do not use freely suspended probes with an FEP cable if effects due to highly charging processes are expected Materials (media wetted) Housing stainless steel.4404 (6 L) Seals FKM FFKM EPDM others on request Diaphragm standard: ceramics Al O 96 % Option: ceramics Al O 99.9 % Nose cone POM Explosion protection Approval DX4-LMK 8 IBExU05ATEX070 X zone 0 5 : II G Ex ia IIB T4 Ga zone 0: II D Ex ia IIIC T85 C Da Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i = 7 nf, L i = 5 µh Permissible media temperature in zone 0: C with p atm 0.8 bar up to. bar zone and higher: C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m 5 for optional stainless steel pipe following designation is valid: "II G Ex ia IIC T4 Ga" (zone 0) Miscellaneous Current consumption max. ma Weight approx. 400 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 004/08/EC pressure measurement

3 Wiring diagram -wire-system (current) -wire-system (voltage) p supply + A p supply + V S VS supply I supply U signal + V Pin configuration Electrical connection cable colours (DIN 4700) Supply + wh (white) Supply bn (brown) Signal + (only for -wire) gn (green) Shield gn/ye (green / yellow) Dimensions (in mm) LMK 8 standard LMK 8 with thread R" for stainless steel pipe LMK 8 dimensions in mm dimensions DN5 / DN40/ DN50 / DN80 / PN6 D k d b f n d

4 Technical Accessories Data Transmitter flange for Technical data LMK 8, LMK 8H, LMK 458, LMK 458H Flange material stainless steel.4404 (6L) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / D = 5, k = 85, b = 8, n = 4, d= 4. kg DN50 / D = 65, k = 5, b = 0, n = 4, d= 8.6 kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4. kg Transmitter flange DN5 / ZFS540 Transmitter flange DN50 / ZFS5040 Transmitter flange DN80 / PN6 ZFS806 Mounting flange with cable gland Technical data all probes Flange material stainless steel.4404 (6L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= kg DN5 / with cable gland brass, nickel plated ZMF540 DN50 / with cable gland brass, nickel plated ZMF5040 DN80 / PN6 with cable gland brass, nickel plated ZMF806 Terminal clamp all probes with cable mm Material standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) Z0058 Z0057 cable gland M6x.5 with seal insert (for cable mm) 04 The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. LMK8_E_0805

5 LMK 8 LMK Pressure in bar in mh O Input [mh O] [bar] Housing Diaphragm Output Seals Electrical connection C E FKM EPDM FFKM 7 PVC-cable PUR-cable FEP-cable TPE-cable 4 Accuracy standard 0.5 % option 0.5 % Cable length Special version Stainless steel.4404 (6L) Ceramics Al O 96% Ceramics Al O 99.9% 4 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire in m standard: m PVC 0 0 standard: 5 m PVC standard: 0 m PVC 0 0 standard: 5 m PVC 0 5 standard: 0 m PVC 0 0 special length PVC standard: m PUR 0 0 standard: 5 m PUR standard: 0 m PUR 0 0 standard: 5 m PUR 0 5 standard: 0 m PUR 0 0 special length PUR standard: 5 m FEP standard: 0 m FEP 0 0 special length FEP special length TPE standard prepared for mounting with stainless steel pipe cable with integrated air tube for atmospheric pressure reference stainless steel pipe is not part of the supply Standard lengths / 5 / 0 / 5 / 0 m are available from stock, special lengths are manufactured order-related, price per meter (see above) This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice.