Mt03. Pre-qualification testing in accordance with NORSOK M-501, rev.5, system no.1 of Jotun no. J-11/N1 2007

Size: px
Start display at page:

Download "Mt03. Pre-qualification testing in accordance with NORSOK M-501, rev.5, system no.1 of Jotun no. J-11/N1 2007"

Transcription

1 Oppdragsgiver Client Jotun Coatings Postboks Sandefjord Norge Utførende enhet/lab. Department/laboratory responsible The National Institute of Technology Materials Technology Pb 2608 St.Hanshaugen NO OSLO Rapportnr. Report no. Tittel Title Pre-qualification testing in accordance with NORSOK M-501, rev.5, system no.1 of Jotun no. J-11/N Dato Date 11/ Utarbeidet av Prepared by Kristian A. Kaltenborn Godkjent av Approved by Jan Scheie Innleveringsdato for prøve Date of receipt of test object 14 Mai 2007 Revisjonsnr. Revision no. Konfig.kont. Config.contr. Antall sider No. of pages Ant. vedlegg No. of append. X Ja Yes Nei No 4 5 Kopi nr. Copy no. Akkred. test Accredited test Kundens ref. Client s ref. Bestillingsnr. Order no. Ja Yes X Nei No Odd Arntzen Fordeling Distribution Prøvingsresultater gjelder utelukkende de prøvede objekter. Utdrag av rapporten må ikke gjengis uten skriftlig godkjenning fra Teknologisk institutt as. Test results relate only to the items tested. The report shall not be reproduced except in full, without the written approval of the laboratory. SK-0016 c N/E

2 Side Page 2 av of 4 1. Summary The following paint system from Jotun Paints AS has been tested in accordance with NORSOK M-501, rev. 5, NORSOK system no 1: Jotun system no. J-11/N1 2007: Substrate Steelpanels, blast-cleaned to Sa 2½ Resist 86 1 x 75 µm Jotacote Universal Al 1 x 150 µm Hardtop PS5 1 x 60 µm Application details as exact DFT values are given in appendix 4. The ageing test was performed from July 11 th 2007 to December 3 rd The paint system is in full accordance with the requirements in NORSOK M-501, rev. 5, system no Reference documents The National Institute of Technology, Materials Technology has tested the following product: Client: Jotun Coatings Product type: Paint system according to NORSOK system no. 1 Paint system: Jotun-11/N Substrate Steelpanels, blast-cleaned to Sa 2½ Resist 86 1 x 75 µm Part A Batch no: F Part B Batch no: 2361 Jotacote Universal Al 1 x 150 µm Part A Batch no: Lab Part B Batch no: EE A Hardtop PS5 1 x 60 µm Part A Batch no: F Part B Batch no: F Comments to the measured DFT: The roughness of the panels is µm. The laboratory interprets that the requirement in the NORSOK standard for the dry film thickness to be within ± 25 % of the NDFT is referring to the total system. The total system: The measured DFT of the total system was OK for all the exposed panels.

3 Side Page 3 av of 4 3. Test methods The pre-qualification tests have been executed in accordance with the standard NORSOK M-501, rev. 5, NORSOK system no 1. All test standards are either ISO- or ASTM-standards and the testing has been executed in full accordance with the requirements given in these standards and with the quality system of the laboratory. 3.1 Test regime, Ageing procedures acc. to ISO Salt Spray ISO h Low-temperature exposure at -20±2ºC 24 h UV-A ISO h One cycle, total time 168 h Total time, 25 cycles à 168 h 4200 h Acceptance Criteria 1. Corrosion creep from scribe: less than 3 mm (average of 9 point measured across the scribe) 2. Blistering ISO Rating 0 3. Rusting ISO Rating 0 4. Cracking ISO Rating 0 5. Adhesion ISO 4624 Min 5,0 MPa, max 50% reduction from original value 6. Overcoatable without mechanical treatment obtain minimum adhesion of 5 MPa. 3 parallel panels shall be tested. Two of three panels shall fulfil the requirements. Panels dried for minimum 14 days after exposure tests before adhesion tests were executed. For the exposure test 3 parallel panels were used. The pull off testing in acc. with ISO 4624 was executed with 6 parallels. Dollies 1,57 cm 2 were used. The uncertainty of the methods (the pull off test) is 10% for adhesion values less then 20 MPa and 15% for adhesion value more than 20 MPa. The scratches were made mechanically with a machine Sajo VRF 52 M. The ageing test was performed from July 11 th 2007 to December 3 rd Results All test results are given in appendix 1 and 2. Corrosion creep is calculated from the average of 9 measurements of the maximum width of the corrosion across the scribe. The maximum width is measured in the middle of the scribe, and in four points on each side of the middle, 5mm between each point. Corrosion creep (M = (C-W)/2, where C is the average of the 9 maximum widths of corrosion across the scribe, and W is the original width of scribe. Application details are given in appendix 3 and 4. Photograph of the tested panels are given in appendix 5. The results from fingerprinting will be given in a separate report.

4 Side Page 4 av of 4 5. Comments and conclusion The ageing resistance (cyclic salt spray/low-temperature exposure/uv resistance) was in accordance with the requirements. The overcoatability after the cyclic test was in accordance with the requirements. Adhesion test results on all exposed panels were in accordance with the requirements. Adhesion test results on unexposed panels were in accordance with the requirements. The paint system is in full accordance with the requirements in NORSOK M-501, rev. 5, system no 1.

5 Vedlegg Appendix 1 NORSOK M-501, rev. 5 Coating System No.1 Test results, each parallel Report no.: Client: Jotun Coatings Paint system code: J-11/N Paint system: Substrate Steelpanels blast-cleaned to Sa 2 1/2 Resist µm Jotacote Universal Al 150 µm Hardtop PS5 60 µm Test parameter Standard Parallel Disbonding Blistering Rusting Cracking Chalking Adhesion *) Overcoatability *) Result NORSOK-std. ISO ISO ISO ISO ISO 4624 ISO 4624 mm Density(Size) Ri Density(Size) Rating MPa MPa Acc./Not acc. Panel no. Req. Res. Req. Res. Req. Res. Req. Res. Req. Res. Req. Mean res. Req. Mean res. Cyclic UVA/Salt spray ISO ,0 1,6 0(S0) 0(S0) 0 0 0(S0) 0(S0) ,1 5 15,2 Accepted 2 3,0 2,2 0(S0) 0(S0) 0 0 0(S0) 0(S0) Accepted 11 3,0 1,8 0(S0) 0(S0) 0 0 0(S0) 0(S0) Accepted Adhesion test, unexposed ISO 4624 Mean ,8 - - Accepted TOTAL EVALUATION Accepted *) The adhesion result in the table is a mean value of 6 parallels from the 3 or 2 parallel test panels for each test method

6 Vedlegg Appendix 2 NORSOK M-501, rev. 5 Coating System No.1 Adhesion test results Report no.: Client: Jotun Coatings Paint system code: J-11/N Paint system: Substrate Steelpanels blast-cleaned to Sa 2 1/2 Resist µm Jotacote Universal Al 150 µm Hardtop PS5 60 µm Test parameter Standard Panel no. Adhesion Overcoatability after exposure ISO 4624 ISO 4624 MPa MPa Cyclic UVA/Salt spray ISO Mean 21,1 15,2 Par. 1 20,0 16,0 Par. 2 21,6 15,4 Par. 3 23,0 15,0 Par. 4 20,6 14,6 Par. 5 21,2 15,0 Par. 6 20,4 15,2 Adhesion test, unexposed ISO 4624 Mean 20,8 Not tested Par. 1 18,0 - Par. 2 21,4 - Par. 3 22,6 - Par. 4 22,4 - Par. 5 22,0 Par. 6 18,4 -

7 Vedlegg Appendix 3 NORSOK M-501, rev. 5 Coating System No.1 APPLICATION OF TESTPANELS Client Jotun Coatings Report no System no J-11/N Surface Preparation: Degreasing Alkaline Date Blast-cleaning Sa 2½ Roughness µm Abrasive Grit Date Paintsystem: Paints 1. coat 2. coat 3. coat Resist 86 Jotacote Universal Al Hardtop PS5 DFT, Batch no.part A F Lab F Batch no.part B 2361 EE A F Thinner - 1. coat Thinner - 2. coat Thinner - 3. coat Thinner no. - No.17 - Thinning - 5,0 % - Conditions during application and curing: Paint 1. coat 2. coat 3. coat Date of application Method of application Airless Airless Airless Pump Wiwa Wiwa Wiwa Inlet pressure, bar Nozzle orifice Thinning - 5 % - Ambient temperature, o C Relative humidity, % Steel temperature, o C Curing of 1. coat Curing of 2. coat Induction time - - Mixing ration: Part A 101kg 4 by vol 1,8 by vol Mixing ration: Part B 23kg 1 by vol 1 by vol Mixing time 5 min 5 min 5 min Application finished 12:00 11:00 08:45 % Solids DFT WFT

8 Vedlegg Appendix 4 NORSOK M-501, rev. 5 Coating System No.1 DFT OF COATED TESTPANELS (n = 5) Client: Jotun Coatings System no J-11/N Report no Substrate: Steelpanels, blast-cleaned to Sa 2 1/2 Paint 1. coat 2. coat 3. coat Resist 86 Jotacote Universal Al Hardtop PS5 DFT Date of measuring: Panel no X Low High Std X Low High Std X Low High Std , , , , , , , , , , , , , , ,8 Accumulated Nominal DFT Accumulated DFT , , ,25 Remarks: All DFT values are reduced with 25µm Calibration on smooth surface

9 Vedlegg Appendix 5 Photo no.1. Panels after Ageing test