SOFC-DA-180KN-192 G652D

Size: px
Start display at page:

Download "SOFC-DA-180KN-192 G652D"

Transcription

1 Description The design of the offered cable has been a typical structure of submarine cables which is prevailing over the world and has been approved for stable performance in submarine cable system. Loose tube/hydrogen ingression protector The protector is made from stainless steel tube, which is filled with appropriate hydrogen ingression gel to protect the optic fiber inside the tube from hydrogen affection Central strength member Stainless steel tubes and fillers are stranded over the central strength member Inner sheath The cable core is protected by a PE sheath for mechanical protection Armoring Double layers of steel wires are stranded over the inner sheath to supply the tensile strength. Interstice between armor layers is filled with asphalt or bitumen Outer serving Two layers of PP-yarn are stranded over the armor wires to protect the cable from mechanical abrasion during handling, transportation and cable deploying, and the corrosion induced by hydrogen in the seawater Cable mark For clear identification during installation, yellow yarns are inserted in the yarn layer. Length marking is carried out in line with the requirements of customer at 500m intervals with a suitable tape 1/5 Rev:31. marts 2014

2 Technical Index Cable properties Central strength member(frp) Nom. O.D 3.8mm Stainless steel tube (with 48 fibers) Nom. O.D 4*3.7mm PE inner sheath Nom. O.D 15.6mm 1st layer steel wire armour 2nd layer steel wire armour 28no./1.9mm 21no./3.3mm Outer PP-yarn serving Nom. O.D 31.5mm Physical Characteristic Weight in air Weight in sea water Ultimate tensile strength (UTS) Nominal temporary tensile strength (NTTS) Nominal operating tensile strength (NOTS) Nominal permanent tensile strength (NPTS) 2.8kg/m 2.2kg/m 300kN 180kN 120kN 75kN Min. bending radius (installing) 1.1m Min. bending radius (operating) 0.8m Crush resistance ( IEC E3 ) Impact resistance ( IEC E4 ) 15kN 200Nm Working temperature -20~+45 Temperature for storage -30~+60 2/5 Rev:31. marts 2014

3 Fiber Identification All fibers in each stainless steel tube have unique fiber coding as shown below for 48 fibers. Remark Fiber No. & Color Without Color Ring Red Black Yellow Violet Pink Aqua With S60 Color Ring With D80 Color Ring With S90 Color Ring S60:Use single black color ring on the fiber surface with 60mm alternation: 60mm 2.0mm D80: Use double black color ring on the fiber surface with 80mm alternation: 80mm 3mm S90: Use single black color ring on the fiber surface with 90mm alternation: 3/5 Rev:31. marts 2014

4 Packing 90mm 2.0mm The cable is wound on the non-returnable steel drum. Both ends of cable are securely fastened to drum and sealed with a shrinkable cap. The required marking is printed with a weather-proof material on the outsides of drum according to customer s requirement. For different length of cable, we provide different packing methods. Cable type Cable dia. length D d B b Estimated gross weight mm drum mm mm mm mm T SOFC-DA [1.9&3.3]-180KN-192G.652D km Note: Above size & weight is estimated, the final size & weight shall be confirmed before shipment. FACTORY ACCEPTANCE TEST Normal FAT only includes OTDR testing, structure checking on samples, and visual checking before delivery. Other tests can be arranged and might be charged. 4/5 Rev:31. marts 2014

5 Optical Characteristic ( G.652D ) Category Description nm 0.35 db/km 0.22 db/km Zero Dispersion Wavelength Zero Dispersion Slope 1300~1324 nm ps/nm2 km nm 3.5 ps/nm km 5.3 ps/nm km 18 ps/nm km Optical Polarization Mode Dispersion (PMD) Cable Cutoff Wavelength (λcc) Macro bending Loss (100 turns; Ф50 nm (100 turns; Ф50 nm 0.2 ps/ km 1260 nm 0.05 db 0.10 db Mode Field nm 9.2±0.4μm 10.4±0. 8μm Dimensional Fiber Curl Radius Cladding Diameter Core / Clad Concentricity Cladding Non-Circularity Coating Diameter Coating / Cladding Concentricity Coating Non-Circularity 4.0 m 125 ±1μm 0.6μm 1.0% 245±10μm 12μm 6.0% Proof Test Level 1% Mechanical Fatigue Resistance Parameter (Nd) 20 Peak Coating Strip Force 1.3~8.9 N For more information, please contact the customer service Hans Følsgaard A/S Tel: Fax: hf@hf.net Hans Følsgaard reserves the right to improve and modify the features and specifications of HF FibreCore air blown fiber cable 5/5 Rev:31. marts 2014