Test Report. No. CANEC Date: 14 Jan Page 1 of 8.

Size: px
Start display at page:

Download "Test Report. No. CANEC Date: 14 Jan Page 1 of 8."

Transcription

1 Test Report. No. CANEC Date: 14 Jan Page 1 of 8. HANGZHOU SILAN MICROELECTRONICS CO.,LTD. NO.4 HUANGGUSHAN ROAD,HANGZHOU,ZHEJIANG CHINA.. The following sample(s) was/were submitted and identified on behalf of the clients as : (L)QFP. SGS Job No. : Model No. :. Client Ref. Info. :. CP GZ. SC51P18A16LLG. SEE REMARK. Date of Sample Received :. 07 Jan Testing Period :. 07 Jan Jan Test Requested :. Test Method :. Selected test(s) as requested by client.. Please refer to next page(s).. Test Results :. Conclusion :. Please refer to next page(s).. Based on the performed tests on submitted sample(s), the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs) and Phthalates such as Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP), and Diisobutyl phthalate (DIBP) comply with the limits as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.. Signed for and on behalf of SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch. Dongyu Xie. Approved Signatory. Zm guan. Approved Signatory.

2 Test Report. No. CANEC Date: 14 Jan Page 2 of 8. Test Results :. Test Part Description :. Specimen No.. SGS Sample ID. Description. SN1. CAN Black plastic w/ brown printing & chip. SN2. CAN Silvery metal pin. Remarks :. (1) 1 mg/kg = %. (2) MDL = Method Detection Limit. (3) ND = Not Detected ( < MDL ). (4) "-" = Not Regulated. RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method :. With reference to IEC :2013+A1:2017, IEC :2013, IEC :2017, IEC :2015 and IEC :2017, analyzed by ICP-OES, UV-Vis and GC-MS.. Test Item(s). Limit. Unit. MDL Cadmium (Cd). 100 mg/kg. 2 ND Lead (Pb). 1,000 mg/kg. 2 ND Mercury (Hg). 1,000 mg/kg. 2 ND Hexavalent Chromium (CrVI). 1,000 mg/kg. 8 ND Sum of PBBs. 1,000 mg/kg. - ND Monobromobiphenyl. - mg/kg. 5 ND Dibromobiphenyl. - mg/kg. 5 ND Tribromobiphenyl. - mg/kg. 5 ND Tetrabromobiphenyl. - mg/kg. 5 ND Pentabromobiphenyl. - mg/kg. 5 ND Hexabromobiphenyl. - mg/kg. 5 ND Heptabromobiphenyl. - mg/kg. 5 ND Octabromobiphenyl. - mg/kg. 5 ND Nonabromobiphenyl. - mg/kg. 5 ND Decabromobiphenyl. - mg/kg. 5 ND Sum of PBDEs. 1,000 mg/kg. - ND Monobromodiphenyl ether. - mg/kg. 5 ND Dibromodiphenyl ether. - mg/kg. 5 ND Tribromodiphenyl ether. - mg/kg. 5 ND Tetrabromodiphenyl ether. - mg/kg. 5 ND

3 Test Report. No. CANEC Date: 14 Jan Page 3 of 8. Test Item(s). Limit. Unit. MDL Pentabromodiphenyl ether. - mg/kg. 5 ND Hexabromodiphenyl ether. - mg/kg. 5 ND Heptabromodiphenyl ether. - mg/kg. 5 ND Octabromodiphenyl ether. - mg/kg. 5 ND Nonabromodiphenyl ether. - mg/kg. 5 ND Decabromodiphenyl ether. - mg/kg. 5 ND Dibutyl phthalate (DBP). 1,000 mg/kg. 50 ND Butyl benzyl phthalate (BBP). 1,000 mg/kg. 50 ND Bis (2-ethylhexyl) phthalate (DEHP). 1,000 mg/kg. 50 ND Diisobutyl Phthalates (DIBP). 1,000 mg/kg. 50 ND Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.IEC series is equivalent to EN series 37,25. RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU. Test Method :. With reference to IEC :2013+A1:2017, IEC :2013, IEC :2015, analyzed by ICP-OES and UV-Vis.. Test Item(s). Limit. Unit. MDL. Cadmium (Cd). 100 mg/kg. 2 ND Lead (Pb). 1,000 mg/kg Mercury (Hg). 1,000 mg/kg. 2 ND Hexavalent Chromium (Cr(VI)). -. µg/cm² ND 002. Notes :. (1) The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863. IEC series is equivalent to EN series 7,25 (2) = a. The sample is positive for CrVI if the CrVI concentration is greater than 0.13 μg/cm². The sample coating is considered to contain CrVI b. The sample is negative for CrVI if CrVI is ND (concentration less than 0.10 μg/cm²). The coating is considered a non-crvi based coating c. The result between 0.10 μg/cm² and 0.13 μg/cm² is considered to be inconclusive - unavoidable coating variations may influence the determination Information on storage conditions and production date of the tested sample is unavailable

4 Test Report. No. CANEC Date: 14 Jan Page 4 of 8. and thus Cr(VI) results represent status of the sample at the time of testing..

5 Test Report. No. CANEC Date: 14 Jan Page 5 of 8. REMARK: SC51F2832LLG/SC51P1816LL/SC9309P/SC6131B/SQ96A81LL/SC1621LL/SC51P1864LL/SC32F5832L L1G/SC51P18A16LLG/SC52F5716LL1G/SC32F5632LL1G/SC52F5732LL1G/SC9711/SC6135B/SC6138 A/SC32F19128LM1G/SC8835D/SQ96A86S/SC7001Q/SC75823W/SC6131A/SC9632/SQ96A82/SQ96B8 2/SC9659P/SC32F58128LB1G/SC6132B/SC8831B/SQ96A82L/SQ96B82L/SC75823E/SC9637B/SC6137 A/SC6136A/SC6136B/SC6137D/SQ96B89/SC8836C

6 Test Report. No. CANEC Date: 14 Jan Page 6 of 8. ATTACHMENTS Pb/Cd/Hg/Cr 6+/PBBs/PBDEs Testing Flow Chart 1) These samples were dissolved totally by pre-conditioning method according to below flow chart. (Cr 6+ and PBBs/PBDEs test method excluded). Sample Preparation Sample Measurement Pb/Cd/Hg PBBs/PBDEs Cr 6+ Acid digestion with microwave / hotplate Solution Filtration Residue 1) Alkali Fusion / Dry Ashing 2) Acid to dissolve Sample solvent extraction Concentration/ Dilution of extraction solution Filtration GC-MS ABS/PC/PVC Others Dissolving by ultrasonication Digesting at 60 C by ultrasonication Nonmetallic material Digesting at 150~160 Separating to get aqueous phase Metallic material Boiling water extraction Adding 1,5- diphenylcarba zide for color development UV-Vis. ICP-OES/AAS ph adjustment Adding 1,5- diphenylcarbazide for color development UV-Vis

7 Test Report. No. CANEC Date: 14 Jan Page 7 of 8. ATTACHMENTS Phthalates Testing Flow Chart Sample cutting / preparation Sample Measurement Solvent extraction Concentration/Dilution Filtration GC-MS

8 Test Report. No. CANEC Date: 14 Jan Page 8 of 8. Sample photo:. CANEC CAN CANEC CAN SGS authenticate the photo on original report only. *** End of Report ***.