1 Prodotto Descrizione Linee guida per la stesura di capitolati tecnici Pag. 1/5 DESCRIPTION STIFERITE is an high performance insulation board manufactured from CFC or HCFC free closed cell rigid polyisocyanurate polyiso foam. It's covered on both side with multilayer facing, and bonded to one side with plasterboard. It is available on request 1 WP made with STIFERITE and a water-repellent plasterboard 12.5 mm MAIN APPLICATIONS Technical insulation and gluing panel Torch application is not recommended with this product GUIDELINE FOR DRAFTING OF TECHNICAL SPECIFICATIONS* Thermal insulation STIFERITE mades with STIFERITE in polyisocyanurate polyiso foam (PIR) of (*), covered on both sides with multilayer facing, and bonded to one side with plasterboard, has: 1 board property : B s1 d0 (EN 13950) Acoustic isolation to wall: Rw = 52 db (UNI and 717-1) Weight percentage of recycled material: % Weight percentage of renewable material: % Thermal insulation property Declareted thermal conductivity: λ D= W/mK (EN Annex A e C) Compressive strength at 10% deformation: minimum value = kpa (EN 826) Compressive strength at 2% deformation: minimum value = kg/m 2 (EN 826) Water vapour diffusion resistance factor: µ > (EN 12086) Water vapour diffusion resistance : Z > m 2 hpa/mg (EN 12086) Flatness after one-sided wetting: FW 10 mm (EN 13165) by total immersion: W lt < 1 % (EN 12087) d by partial immersion: W sp < 0.1 kg/m 2 (EN 1609) : F (EN ) Thickness: 12.5 mm or 9.5 mm Product of Company certified according to UNI EN ISO 9001:2000 specifications, with CE conformity mark on the whole range. (*)Parameters change according to panel. To determine the values corresponding to the used, please use the specifications indicated on this technical sheet. 1 board and performances [EN 13950] Adhesive fixing or solid structure as you want. Vertical and horizontal meetline not protected Euroclass B s1 d0

2 Pag. 2/5 1 board Acoustic isolation to wall [UNI EN ISO 140-3] [UNI EN ISO emission rate of volatile organic compounds [EN ] Weight percentage of recycled material Weight percentage of renewable material Stratigraphy: Brick from 25 mm STIFERITE 1: 62.5 mm (STIFERITE GTC from 60 mm and plasterboard from 12.5 mm) For 70 mm of thick R w [db] available on request % % Thermal insulation characteristics and performances Average initial thermal etermined y [EN 12667] determinad at 10 C λ 90/90,I [W/mK] 0,022 Declared thermal conductivity [UNI EN annex A e C] etermined at 10 C C λ D [W/mk] 0,023 Declared thermal trasmittance U D = λ D / d U D [W/m 2 K] Declared thermal resistance Board density Nominal [EN 823] Compressive strenght [EN 826] Compressive strenght [EN 826] Dimensional stability under specified temperature and umidity [EN 1604] R D = d / λ D Average value with facing caracteristics determinad at 10% deformation determinad at 2% deformation 48h (±1) a 70 C (±2) e 90% RH (±5) 48h (±1) a -20 C (±3) R D [m 2 K/W] ρ [Kg/m 3 ] d N [mm] σ 10 o σ m [kpa] σ 2 [kpa] DS(TH) [% dimensions] ± 1.5 production from 20 to 140 mm [% ] [% dimensions] 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 [% ]

3 Pag. 3/5 Thermal insulation characteristics and performances [EN ] [EN ] [EN (SBI)] [EN ] [EN ] [EN (SBI)] Specific heat capacity Acoustic isolation to wall [UNI EN ISO 140-3] [UNI EN ISO 717-1] Water vapor diffusion resistance factor [EN 12086] Water vapor diffusion resistance [EN 12086] Flatness after one-sided wetting [EN 13165] [EN 12087] Class Euroclass F foam Euroclass E Stratigraphy: Brick from 12 mm STIFERITE GTR from 40 mm Air from 10 mm Brick from 8 mm For 100 mm of thick Total immersion for 28 days Cp [J/kg K] R w [db] 1453 µ (MU) > Z [m 2 hpa/mg] FW [mm] 54 > W lt [%] Less than 1% w [EN 1609] Partial immersion W lp [kg/m 2 ] Less than 0.1 W dv [%] 2.1 ( 20 mm) [EN 12088] By diffusion for 28 days W dv [%] W dp [kg/m 2 ] 0.3 ( 120 mm) 0.43 ( 20 mm) emission rate of volatile organic compounds [EN ] For 80 mm of thick W dp [kg/m 2 ] 0.41 ( 120 mm) available on request

4 Pag. 4/5 Thickness [mm] 12.5 or, on request, 9.5 Density Valore medio [kg/m 3 ] 737 ± 30 Thermal conductivity [UNI ] [W/m K] 0.21 Superficial hardness [UNI 7892] [mm] < 20 Bending strenght Longitudinal Trasversal [N] 400 [N] 160 WP 12.5 Thickness [mm] 832 ± 20 Density Valore medio [kg/m 3 ] 0.23 Thermal conductivity [UNI ] [W/m K] < 20 Superficial hardness [UNI 7892] [mm] 550 Bending strenght Longitudinal Trasversal [N] 210 [N] 12.5

5 - WP Pag. 5/5 Tolerances and notes Tolerances [UNI EN 13165] Thickness Dimensions T2 [mm] < 1000 ±5 mm <50 ±2 mm from 1000 to 2000 ±7,5 mm from 50 to 75 ±3 mm from 2000 to 4000 ±10 mm >75 +5 /-2 mm > 4000 ±15 mm Notes stability to the temperature Stiferite panels are used in a range of continuous temperatures normally included between -40 C e +110 C. During short time they can resist also to temperatures till C, or corresponding to the temperature of fused bitumen, without particular problems. Long exposures to the temperatures could cause deformations to the foam or to the coats, but without causing sublimation or fusion. Resistance to the torch and some other reactions to fire are characteristics connected with the kind of used panel. Aspect Any possible little areas of non-adhesion between coats and foam are originated by the production process and don t prejudice in any way the physical-mechanical properties of the panels.