EC type-examination certificate UK/0126/0059 Revision 7

Size: px
Start display at page:

Download "EC type-examination certificate UK/0126/0059 Revision 7"

Transcription

1 UK/0126/059 MI-001 EC type-examination certificate UK/0126/0059 Revision 7 issued by: The National Measurement and Regulation Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Cold-water Meters) Regulations 2006 (SI 2006/1268) and the Measuring Instrumentss (Non-Prescribed Instruments) Regulations 2006 (SI 2006/1270) which implement, in the United Kingdom, Council Directive 2004/22/EC, this certificate of EC type-examination has been issued to: Arad Ltd. Dalia - Ramot Menashe POB19239 Dalia Israel in respect of a cold-water meter designated Gladiator utilising a volumetric rotary-piston measuring element, and having a rated permanent flowrate Q 3 of: 1.6m 3 /h (R315), or 2.5m 3 /h (R400), or 4.0m 3 /h (R250). The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. This Revision replaces previous versions of the certificate. Issue Date: Valid Until: Reference No: 14 January October 2020 T1132/ /0026 G Stones Technical Manager NMRO Technical Services For and on behalf of the Chief Executive National Measurement and Regulation Office I Stanton Avenue I Teddington I TW11 OJZ I United Kingdom Tel +44 (0) I Fax +44 (0) I Web The NMRO is an Executive Agency of the Department for Business Innovation and Skills 0135 MID Annex B Rev January 2016

2 Descriptive Annex 1 INTRODUCTION This pattern of a liquid measuring instrument is for measuring the volume of cold water which has passed through it. It is a concentric, semi-positive displacement cold-water meter having a Q 3 (permanent flowrate) of 1.6m 3 /h and a Q 3 /Q 1 turndown ratio of 315 (R315) or a Q 3 (permanent flowrate) of 2.5m 3 /h and a Q 3 /Q 1 turndown ratio of 400. It is not designed to measure reverse flow. The meter is shown in Figure 1 2 FUNCTIONAL DESCRIPTION It incorporates a semi-positive displacement rotary piston measuring assembly mounted in a plastic body that is fitted into a thermoplastic injection moulded body for connection to a manifold in any orientation. The rotary piston drives a magnet that couples to a non-resettable totalising display (register) that indicates up to m 3. The register is positioned on the top of the measurement chamber and secured between the plastic snap-shut register cover and meter body. The connection to the manifold is arranged via a British Pipe Thread G1½"A male threaded co-axial inlet/outlet at the base of the meter body. A cross section diagram is shown in Figure 2. 3 TECHNICAL DATA 3.1 Flow designation Meter with Q 3 = 1.6 m 3 /h Table 1 Related flowrates according to each Q 3 /Q 1 designation Q 3 /Q 1 (R) Q 2 /Q Q 1 Minimum flowrate (m 3 /h) Q 2 Transitional flowrate (m 3 /h) Q 3 Permanent flowrate (m 3 /h) Q 4 Overload flowrate (m 3 /h) Meter with Q 3 = 2.5 m 3 /h Table 2 Related flowrates according to each Q 3 /Q 1 designation Q 3 /Q 1 (R) Q 2 /Q Q 1 Minimum flowrate (m 3 /h) Q 2 Transitional flowrate (m 3 /h) Q 3 Permanent flowrate (m 3 /h) Q 4 Overload flowrate (m 3 /h)

3 3.1.3 Meter with Q 3 = 4.0 m 3 /h Table 3 Related flowrates according to each Q 3 /Q 1 designation 3.2 Other designations Q 3 /Q 1 (R) 250 Q 2 /Q Q 1 Minimum flowrate (m 3 /h) Q 2 Transitional flowrate (m 3 /h) Q 3 Permanent flowrate (m 3 /h) 4.0 Q 4 Overload flowrate (m 3 /h) 5.0 Q m 3 /h Q m 3 /h Q m 3 /h Temperature class: T50 (0.1 C 50 C) Orientation None requirements Revs/litre of measuring chamber Maximum admissible 16 bar pressure (MAP) Pressure Loss at Q 3 P16 40 Climatic environment: -10 C to 55 C Mechanical M1 environment: Electromagnetic environment: n/a Location: Open/closed, condensing/non-condensing Reverse Flow: The meter is not designed to measure reverse flow Minimum straight D0/U0 length of inlet/outlet pipe 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Mechanical register with electronic 3G unit The register is similar to the standard mechanical register but contains an electronic 3G communication device for remote reading of the measurement. The transmission of measurement data using this device is not covered by this approval. This device has three variations; one powered by A cell batteries, the second powered by AA cell batteries and a third powered by Tadiran Lithium Batteries. 3

4 5 APPROVAL CONDITIONS The certificate is issued subject to the following conditions: 5.1 Legends and inscriptions The instrument bears the following legends: CE marking Supplementary metrology marking Notified body identification number Permanent flow rate Q 3 Flowrate range Q 3 /Q 1 (R) Serial number Manufacturers mark or name Certificate number 6 LOCATION OF SEALS AND VERIFICATION MARKS 6.1 Securing method The measuring assembly is secured by locating the snap fit plastic cover to the meter body. The register is positioned between the plastic cover and the meter body. The plastic cover and meter body have integrally moulded clips and once fitted, unauthorised dismantling is not possible without leaving evidence of tampering. 6.2 Location of verification markings The verification markings identified in 5.1 are permanently etched on the top surface of the shroud. 7 AUTHORISED ALTERNATIVES 7.1 Electronic Register CZ-4000 Having an electronic register model CZ-4000 as described in Evaluation Certificate GB

5 7.2 Inline Meter Groups PD 15 and PD 20 As described in the certificate, but configured for in-line connection into the water pipe. The meter is sealed as shown in Figure 6. The meters body s length range is 110 to 190 mm, having two options of strainers (finger or basket type).the meters are dedicated for ½ and ¾ pipe lines, coupling threads inlet/outlet ¾ and 1,BSP/NPSM types, examples of the ½ are shown in Figure Inline Group PD 15 Specifications Related flowrates according to each Q 3 /Q 1 designation Q 3 /Q 1 (R) Q 2 /Q Q 1 Minimum flowrate (m³/h) Q 2 Transitional flowrate (m³/h) Q 3 Permanent flowrate (m³/h) Q 4 Overload flowrate (m³/h) Other designations Temperature class T50 (0.1 C-50 C) Orientation requirements None Revs/litre of measuring chamber Maximum admissible pressure (MAP) 16 bar Pressure Loss at Q3=2.5 [m³/h] P 63 Pressure Loss at Q3=1.6 [m³/h] P 25 Climatic environment (-)10 C (+)55 C Mechanical environment M1 Electromagnetic environment NA Location Open/closed. condensing/non condensing Reverse flow Not designed to measure reverse flow Minimum straight length of inlet/outlet pipe D0/U0 5

6 Meter options Model name Inlet φ Outlet φ Length Height Threads Connections PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP PD1/ NPSM / BSP Inline Group PD 20 Specifications Related flowrates according to each Q 3 /Q 1 designation Other designation Temperature class Orientation requirements Q 3 /Q 1 (R) Q 2 /Q Q 1 Minimum flowrate (m³/h) Q 2 Transitional flowrate (m³/h) Q 3 Permanent flowrate (m³/h) Q 4 Overload flowrate (m³/h) Register type Q m 3 /h Q m 3 /h T50 (0.1 C-50 C) None Revs/litre of measuring chamber Maximum admissible pressure (MAP) 16 bar Pressure Loss at Q 3 =2.5 [m³/h] P 40 P 63 Climatic environment (-)10 C (+)55 C Mechanical environment Electromagnetic environment Location M1 NA Open/closed condensing /non condensing 6

7 Reverse flow Minimum straight length of inlet/outlet pipe Not designed to measure reverse flow D0/U Meter options Model name Inlet φ Outlet φ Length Height Threads Connections Register type PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP PD3/ NPSM / BSP Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / Standard / AMR / Optical / 7.3 Alternative Dial Face Printing (Figures 4 and 5) As described in the certificate but having the resolution of the last dial with a minimum division of 0.02 l instead of 0.5 l, therefore the display (register) indicates up to m 3. 8 ILLUSTRATIONS Figure 1 Gladiator Concentric Meter Figure 2 Sectional view of Gladiator Concentric Meter Figure 3 Gladiator Meter dial face and markings Figure 4 Alternative Gladiator Meter dial face and markings Q 3 = 1.6 m 3 /h Figure 5 Alternative Gladiator Meter dial face and markings Q 3 = 2.5 m 3 /h Figure 5.a Gladiator Meter dial face and markings Q 3 = 4.0 m 3 /h Figure 6 Gladiator In-line meter sealing Figure 7 Sectional views of Gladiator In-line meter options 7

8 9 CERTIFICATE HISTORY ISSUE NO. DATE DESCRIPTION UK/0126/ nd October 2009 Type examination certificate first issued. UK/0126/0059 Revision 1 2 nd February 2009 Figure 3 Updated to show positioning of Certificate Number UK/0126/0059 Revision 2 25 August 2011 Section 4.1 edited to allow for 2 types of 3G register. Section 7 Authorised Alternatives added, subsequent sections renumbered Section 7.1 added, Electronic register Section 7.2 added, In line meter UK/0126/0059 Revision 3 17 January 2012 Section added, Q 3 of 2.5m 3 /h, reference to Q 3 of 2.5m 3 /h also added to front page. Section 3.2 Q 3 of 2.5 m 3 /h characteristics added. Pressure loss of Q 3 of 1.6 m 3 /h corrected to P25 from P63 Section 7.2, extra description of inline meter added, including examples in Figure 5. UK/0126/0059 Revision 4 22 March 2012 Section 7.3 added, Alternative Dial Face printing. Associated Figures 4 and 5 added, subsequent figures renumbered. UK/0126/0059 Revision 5 15 March 2013 Section 3.2 Minimum straight length of inlet/outlet pipe D0/U0 added, Pressure Losses at Q3 corrected from P25 to P16 and P63 to P 40 Section 7.2 title updated to include in line Meter Group PD 20 Sections and added UK/0126/0059 Revision 6 1 July 2014 Section Table 1 updated to include R160. Section Table 2 updated to include R200 and R160 Section 4.1 Lithium battery option added. 8

9 UK/0126/0059 Revision 7 14 January 2016 Front page and section 3.2 Q m 3 /h added. Section Table addition meter options added Section Table added Q3=4 parameters Section Table added Q3=4 parameters Section Table addition meter options added Section 8 Figure 5.a added, Figures 4 and 5 have updated new Arad Logo has added. 9

10 Figure 1 Gladiator Concentric Meter 10

11 Figure 2 Sectional view of Gladiator Concentric Meter 11

12 Figure 3 Gladiator Meter dial face and markings Figure 4 Alternative Gladiator Meter dial face and markings Q3 = 1.6 m3/h Figure 5 Alternative Gladiator Meter dial face and markings Q3 = 2.5 m3/h 12

13 Figure 5.a Gladiator Meter dial face and marking Q 3 = 4.0 m 3 /h 13

14 Seal Figure 6 Gladiator In line meter 14

15 15

16 16

17 17

18 Figure 7 Sectional views of Gladiator In-line meter options Crown Copyright 2016 National Measurement Office Department of Business, Innovation & Skills This material may be freely reproduced except for sale. 12