Detection tubes for most common TICs. Tubes dimensions 6 x 105 mm Usable in different hand and electric pumps

Size: px
Start display at page:

Download "Detection tubes for most common TICs. Tubes dimensions 6 x 105 mm Usable in different hand and electric pumps"

Transcription

1 TICs DETECTION TUBES tubes for most common TICs Tubes dimensions 6 x 105 mm Usable in different hand and electric pumps Tube DT11 in a hand pump UNIVERSAL, CZ Tube DT12 in a hand pump Draeger, DE El. pump CHP-5, ORITEST, CZ Poštovní adresa Mail address: Nábřežní 90/ Praha 5 Česká republika Tel: Fax: oritest@oritest.cz Registrace v OR Městský soud Praha Složka C12216 IČO: DIČ: CZ GE Money Bank a.s. Praha č.ú.: /0600 CZ CZK CZ EUR Asociace obranného a bezpečnostního průmyslu ČR Defence and Security Industry of the Czech Republic Association Verze

2 TIC DETECTION TUBE DT 001 PHOSGENE DT-001 Sensitivity 0,5 mg.m -3 Interferences Temperature 0-50 C Phosgene COCl 2 DT-001 Yellowish red Phosgene and Diphosgene react with s 4-(p-nitrobenzyl)pyridine creating quartere ammonia salts. The detection tube contains one indication layer formed by silica gel impregnated with 4-(p-nitrobenzyl)pyridine and N-fenylbenzylamine. A prescribed number of strokes are executed (equivalent air volume). of the Similar colour as phosgene creates also acethylchloride, benzoyl chloride and other acylation substances. High concentration of hydrogen chloride and other strongly acid gases and vapours may interfere ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

3 TIC DETECTION TUBE DT 002 HYDROGEN CYANIDE, CYANOGEN CHLORIDE DT-002 Sensitivity 3 mg.m -3 Temperature 0-50 C Hydrogen cyanide HCN DT-002 AC: grey red - violet CK: yellowish red - violet Hydrogen cyanide reacts with 4-nitrobenzaldehyde with presence of pyridine creating coloured benzoine. Cyanogen chloride reacts according to König with pyridine and dimedone to polymethic dye. The tube contains two layers and an ampoule with detection solution. The upper layer is a silica gel impregnated by natrium hypocarbonide, lower layer is a silica gel impregnated with dimedone, and detection solution conzains 4-nitrobenzaldehyd in pyridine. First to crush the ampoule, then to provide described number of strokes (equivalent air volume. of the Tabun can be also detected (creates hydrogen cyanide). Cyanogen bromide and fosgenoxime react similarly as cyanogens chloride. ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

4 TIC DETECTION TUBE DT 003 CHLORINE DT-003 Sensitivity 3 mg.m -3 Interferences Temperature Chlorine Cl 2 DT-003 Yellow - red of chlorine with potassium bromide releases bromide that creates a red product with fluoresceine. The tube contains one indication layer, silica gel impregnated with chromogen reagents (potassium bromide and fluoresceine). To provide described number of strokes (equivalent air volume. of the The tube can detect also another strong oxidating reagents mainly bromide or natrium dioxide (in a higher concentration). Tube sensitivity is influenced presence of high concentration of acid gases and vapours o C ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

5 TIC DETECTION TUBE DT 004 NATRIUM OXIDES DT-004 Sensitivity 2 mg.m -3 Temperature 0-50 C Natrium oxides NO x DT-004 White yellow up brown of natrium dioxide with potassium iodide releasing iodide The tube contains one indication layer, silica gel impregnated with potassium iodide. To provide described number of strokes (equivalent air volume. of the The tube can detects also other strong oxidizers mainly chlorine and bromine.. ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

6 TIC DETECTION TUBE DT 005 SULPHUR DIOXIDE DT-005 Sensitivity 5 mg.m -3 Interferences Sulphur dioxide SO 2 DT-005 White yellow Temperature 0-40 C of sulphur dioxide with Ellman reagent creating coloured thiolate. The tube contains one indication layer, silica gel impregnated Ellman reagent and the buffer. To provide described number of strokes (equivalent air volume. of the Sulphide reacts similarly Presence of high concentration of acid gases and vapours. ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

7 TIC DETECTION TUBE DT 006 SULPHIDE DT-006 Sensitivity 5 mg.m -3 Interferences Temperature 0-50 C Sulphide H 2 S DT-006 Light blue - brown of sulphide with cupric ions creating colouric cooper sulphide. The tube contains one indication layer, silica gel impregnated with cooper acetate. To provide described number of strokes (equivalent air volume. of the The reaction is specific. The reaction system is very resistant to interferences. ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

8 TIC DETECTION TUBE DT 007 CARBON DISULPHIDE DT-007 Sensitivity 20 mg.m -3 Temperature 0-50 C Carbon disulphide CS 2 DT-007 Light blue yellow up brown of carbon disulphide with cupric ions and piperazine creating coloric cupric dithiocarbamate.. The tube contains one indication layer, silica gel impregnated with cupric acetate and piperazine. To provide described number of strokes (equivalent air volume. of the Sulphide creates similar colour. ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

9 TIC DETECTION TUBE DT 008 AMMONIA DT-008 Sensitivity 50 mg.m -3 Temperature 0-50 C Ammonia NH 3 DT-008 Yellow green up blue of ammonia with phosphoric acid a change of ph is indicated by acidobasic indicator with bromo-cresol greenth. The tube contains one indication layer, silica gel impregnated with bromo-cresol greenth, phosphoric acid and glycerine. To provide described number of strokes (equivalent air volume. of the Similarly react also another alcalic gases and vapours, e.g. volatile, aliphatic and cyclic amines and hydrazines.. ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

10 TIC DETECTION TUBE DT 009 HYDROGEN CHLORIDE DT-009 Sensitivity 10 mg.m -3 Hydrogen chloride HCl DT-009 Yellow - red Interferences 0-50 C of hydrogen chloride with an alkalia, a change of ph is indicated by acido basic indicator with methyl orange.. The tube contains one indication layer, silica gel, impregnated with methyl orange. To provide described number of strokes (equivalent air volume. of the Similarly react also another acid gases and vapours, e.g. phosgene, phosphor chloride, organic and mineral acids. Temperature The tube can be used in a broad range of air humidity (10 95%) Humidity ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

11 TIC DETECTION TUBE DT 010 FORMALDEHYDE DT-010 Sensitivity 0,5 mg.m -3 Formaldehyde HCHO DT-010 White - violet of formaldehyde with specific reagent creates coloured 6-merkapto-5-triazol- (4,3-b)-s-tetrazine. The tube contains one indication layer and an ampoule with solution. The layer is of Silica gel impregnated with chromogene reagent. Saturated solution of natrium perchlorate in 10% natrium hydrate. To provide described number of strokes (equivalent air volume. of the indication layer should be compared with the etalon on the label. Similar reaction is with volatile aldehydes. The colour could be different. Intervferences Acid agents in air degreses the tube sensitivity. Temperature 0-50 o C ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version

12 TIC DETECTION TUBE DT 011 CARBON MONOXIDE DT-011 Carbon Monoxide CO, DT011 Sensitivity 30 mg.m -3 Light yellow red Trivalent ferrum reduction to dixalent one. Creates a colour complex with o-fenantroline. Interferences Temperature The tubes contains one indication layer and an ampoule with solution. The layer is of Silica gel impregnated with iron chloride. Ethanol solution of o-fenatroline is in the ampoule. To provide described number of strokes (equivalent air volume. of the indication layer should be compared with the etalon on the label. Similar reaction is with another reduction compounds e.g. sulphur dioxide, sulphide, thiols etc. Sulphide creates a brown colour even before the ampoule crushing o C ORITEST spol. s r.o., Nábřežní 90/4, Praha 5, Czech Republic Tubes Specification Sheet version