CLASSIC Series TRICOR Coriolis Mass Flow Meters

Size: px
Start display at page:

Download "CLASSIC Series TRICOR Coriolis Mass Flow Meters"

Transcription

1 TECHNICAL DATASHEET The CLASSIC product line meets general industrial requirements out of the box. TCE 8000 transmitters with an easy-to-use interface Economically-priced, non-calibrated but with excellent repeatability Optional custom-calibrated meters with high performance specifications

2 CONTENT Description, Principle of operation... 0 Product Overview Sensor Technical Data for Liquids Accuracy for Liquids Sensor Technical Data for Gases Accuracy for Gases Our passion is your Process TCE 8000/8100 Transmitter Technical Data TCE 6000 Transmitter Technical Data TRD 8001 Remote Display - Technical Data Dimensional Drawings Ordering Meter (TRICOR CLASSIC Series) Ordering TCE Transmitter (Series 8XXX) Process Connections TRICOR Connection Cable (TCC) for Panel-Mounted Housing... 5 Additional Accessories... 5 Contact

3 DESCRIPTION The TRICOR Coriolis Mass Flow Meters from TASI Flow are absolutely reliable and robust sensors in a variety of processes, performing multiple measurements simultaneously with customizable process parameters and multiple communication languages. The TRICOR production team mechanically balances every meter, assuring the dual tubes are dynamically aligned and in perfect balance before flow begins. The unique design and cutting edge manufacturing procedures ensure a meter with the highest resistance to external influences. PRODUCT OVERVIEW Compact version FEATURES All-in-one instrument: direct measurement of mass flow, density and temperature, calculated measurement of volumetric flow No moving parts: low maintenance, no need for recalibration Easy to install: no straight run of pipe required and multiple mounting options available Mechanically balanced tubes and superior mechanical design for best-in-class density measurement Exceptional mechanical design resists external interference API gravity reading in software Exceptional ease of use and fast setup time: we will preprogram your process parameters Frequency output up to 10,000 Hz resolution Superior meter calibration: DAkkS-Accreditation as per DIN EN ISO/IEC 1705:005 Easily accessible, integrated meter diagnostics to verify meter health & performance Hazardous area certifications: ATEX, IECEx, ccsaus, EAC (TR-CU) Customized process connections available PRINCIPLE OF OPERATION Coriolis Mass Flow Meters () operate with two tubes with coils that cause them to oscillate at their resonance frequency. Should a measurement flow enter the measuring tube, Coriolis forces are the result. Coriolis forces appear in oscillating systems when a mass moves towards or away from a rotational axis. These forces act on the inlet and outlet side in the opposite direction and minimally deform the measuring tubes. The deflection of the measurement tubes is captured by sensors on the inflow and outflow side. These two sensors measure a phase shift that is proportional to the mass flow. The resonance frequency of the tubes varies depending on the density of the medium to be measured. This effect is used to measure the density of the medium. Since the elastic properties of the flow tubes depend on the temperature, a temperature measurement is carried out for compensation. The primary characteristics such as mass flow rate, density and temperature are measured with a single flow meter. The volume flow can be determined based on the mass flow rate and density. Exd housing: Wall mounted (remote version) ADDITIONAL OPTIONS Net Oil software High pressure designs available up to 345 bar [5,000 psi] Special calibrations for an oil viscosity up to 100 mm /s Integrated pressure compensation Customizable installation length Extended warranty Version with TCE 6000 (including options) Housing: Panel mounted (remote version) t T phase shift = mass flow 4 5

4 SENSOR TECHNICAL DATA FOR LIQUIDS ACCURACY FOR LIQUIDS 035 Max. Flow Rate (kg/h) ,550 3,100 5,500 7,900 8,000 65,000 30,000 Max. Flow Rate (lb/min) ,09,388 8,450 Basic Accuracy (Mass Flow) Basic Accuracy (Volume Flow) Repeatability Zero Stability 08K ±0.3 % of flow rate (option: up to 0.1 % of flow rate) ±0.4 % of flow rate (option: up to 0.15 % of flow rate) ±0.05 % of flow rate ±0.01 % of full scale 30K Standard (Single-Point Calibration, Basic Accuracy: ±0.3 %) Custom (Five-Point-Calibration, Basic Accuracy: ±0.1 %) Density Range up to,500 kg/m³ [.5 g/cm 3 ] (higher ranges on request) Density Accuracy ±5.0 kg/m3 [±0.005 g/cm 3 ] (option: ±1.0 kg/m3 [±0.001 g/cm 3 ]) Density Repeatability ±0.5 kg/m 3 [± g/cm 3 ] Process Temperature Range Temperature Repeatability Process and Ambient Process Connections female thread 1/ adaptors for flanges, dairy and tri-clamp Max. Pressure Standard Pressure Drop at max. Flow ±1 C ±0.5 % of reading [±1.8 F ±0.5 % of reading] ±0. C [±0.36 F] 00 bar [,900 psi] option: up to 345 bar [5,000 psi] (not forasme) for detail information please contact us Process Temperature (non Ex) -40 C C [-40 F F] (standard) -40 C C [-40 F F] (option) -60 C C [-76 F F] (option) flanges EN109, ANSI B16.5, DIN51, threaded tri-clamp 100 bar [1,450 psi] Process Temperature (Ex) meter mount -40 C C [-40 F F] (T4) n/a remote version -40 C C [-40 F F] (T4) -40 C C [-40 F F] (T3) -60 C C [-76 F F] (T) Ambient Temperature -40 C C [-40 F F] Storage Temperature -40 C C [-40 F F] Electr. Connections Remote Electr. Connections Meter Mount screw type terminals none (internally connected to the electronics) Example for a standard 035 (Single-Point Calibration, Basic Accuracy: ±0.3 %) 35 kg/h * Zero Point (0.01 %) = kg/h [1 lb/min * 0.01 % = lb/min] 35 kg/h * Basic Accuracy (0.3 %) = kg/h [1 lb/min * 0.3 % = lb/min] Result: (0.035 / 0.975) * 100 = 3.33 % (10.8 kg/h) [(0.001 / 0.036) * 100 = 3.33 % (0.4 lb/min)] < Flow Rate of Full Scale Zero Point Basic Accuracy Zero Point Basic Accuracy * 100 * 100 ± Accuracy ± Basic Accuracy Zero Point Measured Value * 100 Example for a custom 035 (Five-Point Calibration, Basic Accuracy: ±0.1 %) 35 kg/h * ZeroPoint (0.01 %) = kg/h [1 lb/min * 0.01 % = lb/min] 35 kg/h * Basic Accuracy (0.1 %) = 0.35 kg/h [1 lb/min * 0.1 % = 0.01 lb/min] Result: (0.035 / 0.35) * 100 = 10 % (3.5 kg/h) [(0.001 / 0.01) * 100 = 10 % (1. lb/min)] Ingress Protection IP65 (IP66/IP67 on request) All Flow Rates 3.33 % or 10.8 kg/h (0.4 lb/min): Measured Error = Basic Accuracy All flow rates 10 % or 3.5 kg/h (1. lb/min): Measured error = Basic Accuracy General Tube Arrangement serial serial Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 8 mm 43 mm Tube Material [AISI 316L] Housing Material [AISI 316L] Dimensions see dimensional drawings (page 10-11) All Flow Rates < 3.33 % or 10.8 kg/h (0.4 lb/min): Measured Error = (Zero Point / Measured Value) * 100 All flow rates < 10 % or 3.5 kg/h (1. lb/min): Measured error = (Zero Point / Measured Value) * Calibration for Liquids and Gases: The TRICOR flowmeters are always factory calibrated with water. Calibration Conditions: Water: 0 C... 5 C [68 F F], ambient temperature: 0 C... 5 C [68 F F]. All specifications are based on above mentioned calibration reference conditions, a flow calibration protocol is attached to each instrument. Stated accuracy combines the effects of repeatability, linearity and hysteresis. Typical flow dynamics based on max. flow rate is 100:1. 7

5 SENSOR TECHNICAL DATA FOR GASES ACCURACY FOR GASES 035 Nom. Flow Rate (kg/h) 1) 3) ,430 5,100 15,650 48,900 Nom. Flow Rate (lb/min) 1) 3) ,797 Nom. Flow Rate (Nm 3 /h) 1) ) ,031 1,68 1,993 7,109 1,813 68,157 Nom. Flow Rate (SCFM) 1) ) ,173 4,184 1,838 40,115 Basic Accuracy Repeatability 08K ±1 % of flow rate (option: up to ±0.5 % of flow rate) ±0,5 % of flow rate Zero Stability (kg/h) Zero Stability (lb/min) K Standard (Single-Point Calibration, Basic Accuracy: ±1 %) Custom (Five-Point-Calibration, Basic Accuracy: ±0.5 %) Density Range see comment 3) Density Accuracy ±5.0 kg/m 3 [±0.005 g/cm 3 ] (option: ±1.0 kg/m 3 [±0.001 g/cm 3 ] Density Repeatability ±0.5 kg/m 3 [± g/cm 3 ] Process Temperature Range Temperature Repeatability Prozess-/Umgebungsbedingungen Process Connections female thread 1/ adaptors for flanges, dairy and tri-clamp Max. Pressure Standard Pressure Drop at max. Flow ±1 C ±0.5 % of reading [±1.8 F ±0.5 % of reading] ±0. C [±0.36 F] 00 bar [,900 psi] option: up to 345 bar [5,000 psi] (not for ASME) for detail information please contact us flanges EN109, ANSI B16.5, DIN51, threaded tri-clamp Process Temperature (non Ex) -40 C C [-40 F F] (standard) -40 C C [-40 F F] (option) -60 C C [-76 F F] (option) 100 b ar [1,450 psi] Process Temperature (Ex) meter mount -40 C C [-40 F F] (T4) n/a remote version -40 C C [-40 F F] (T4) -40 C C [-40 F F] (T3) -60 C C [-76 F F] (T) Ambient Temperature -40 C C [-40 F F] Storage Temperature -40 C C [-40 F F] Electr. Connections Remote Electr. Connections Meter Mount screw type terminals none (internally connected to the electronics) Example for a standard 035 (Single-Point Calibration, Basic Accuracy: ±1 %) 35 kg/h * Zero Point (0.01 %) = kg/h [1 lb/min * 0.01 % = lb/min] 35 kg/h * Basic Accuracy (1 %) = 3.5 kg/h [1 lb/min * 1 % = 0.1 lb/min] Result: (0.035 / 3.5) * 100 = 1 % (3.5 kg/h) [(0.001 / 0.1) * 100 = 1 % (0.1 lb/min)] < Flow Rate of Full Scale Zero Point Basic Accuracy Zero Point Basic Accuracy * 100 * 100 ± Accuracy ± Basic Accuracy Zero Point Measured Value * 100 Example for a custom 035 (Five-Point Calibration, Basic Accuracy: ±0.5 %) 35 kg/h * ZeroPoint (0.01 %)= kg/h [1 lb/min * 0.01 % = lb/min] 35 kg/h * Basic Accuracy (0.5 %) = 1.65 kg/h [1 lb/min * 0.5 % = 0.06 lb/min] Result: (0.035 / 1.65) * 100 = % (6.5 kg/h) [(0.001 / 0.06) * 100 = % (0.4 lb/min)] Ingress Protection IP65 (IP66/IP67 on request) All Flow Rates 1 % or 3.5 kg/h (0.1 lb/min): Measured Error = Basic Accuracy All flow rates % or 6.5 kg/h (0.4 lb/min): Measured error = Basic Accuracy General Tube Arrangement serial serial All Flow Rates < 1 % or 3.5 kg/h (0.1 lb/min): Measured Error = (Zero Point / Measured Value) * 100 All flow rates < % or 6.5 kg/h (0.4 lb/min): Measured error = (Zero Point / Measured Value) * 100 Tube Inner Diameter 4 mm 4 mm 8 mm 8 mm 7 mm 9 mm 16 mm 8 mm 43 mm Tube Material [AISI 316L] Housing Material [AISI 316L] EX CERTIFICATIONS Dimensions see dimensional drawings (page 10-11) ATEX (Ex) Zone 1: Group IIC or IIB, T...T4 ATEX (Exn) Zone : II 3G Ex na IIC T...T4 Gc IECEx (Ex) Zone 1: Group IIC or IIB, T...T4 ccsaus (Ex1) 4) Class 1, Division 1: Group A, B, C, D or C, D, T T4 8 Max. allowed flow velocity (Ma 0.5). For gas applications, flow rate and pressure drop for individual sensor sizes are dependent on operating temperature, pressure and fluid composition. Therefore, when selecting a sensor for any particular gas application, please use the the TSP (TRICOR Sizing Program) or contact us. 1) Nominal flow rates that produce approximately 3 bar [43 psi] pressure drop for natural gas at 50 bar [75 psi] operational pressure. ) Normal reference conditions (Nm 3 /h) are 1,013 bar und 0 C. Standard (SCFM) reference conditions are 14.7 psi und 60 F. 3) Flow rate and density range depend on the gas density and the pressure range. ATEX + IECEx + ccsaus triple Zone 4) 5) approval (Ex3) EAC (TR-CU) 4) 1: Group IIC or IIB, T...T4 and Class 1, Division 1: Group A, B, C, D or C, D, T T4 Group IIC or IIB, T T4 4) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing. 5) Only with remote electronics. 9

6 TCE 8000/8100 TRANSMITTER TECHNICAL DATA TCE 6000 TRANSMITTER TECHNICAL DATA General Display Supply Voltage Programming Interface back-lit LCD screen, 13 x 3 dot 4 V DC, ±0 % or V (version dependent) via front keyboard or Windows-based TRICOR configurator program (Modbus) EMV according to EN and Power Consumption ExD Housing: Wall-mounted RS485 (Modbus-RTU), option HART, Foundation Fieldbus, other options on request max. 6 W Dimensions see dimensional drawing (page 1-13) Electrical Connections Cable Glands Housing Material Protection Class cage clamp terminals for 7-13 mm cables aluminum diecast (option: [AISI 316L]) IP65 (IP66/IP67 on request) Weight with aluminum diecast housing: 3.8 kg [8.3 lb] with 3 m cable with [AISI 316L] housing: 6.15 kg [13.56 lb] Temperature ambient: -40 C C [-40 F F] storage and transport: -40 C C [-40 F F] Housing: Panel-mounted (only TCE 8000) Dimensions see dimensional drawing (page 15) Electrical Connections Housing Material Protection Class Weight cage clamp terminals Noryl front: IP50, rear: IP kg [0.88 lb] Temperature ambient: ±0 C C [3 F... + F] storage and transport: -0 C C [-4 F F] Analog Output Current Outputs (x) Resolution Linearity Temperature Drift Load Output Value Pulse Output Frequency Range Output Signal Status In- and Output Status Output Control Input Analog Input (option) Input Type Resolution Linearity Temperature Drift Supply Voltage ma passive, two-wire, isolated 14 bit ±0.05 % of full scale 0.05 % per 10 K < 60 Ω (at 4 V supply) programmable: flow, total, density, temperature ,000 Hz (in TOTAL mode: Hz) active push pull output for flow rate push pull programmable (in FREQUENCY mode: ,000 Hz) programmable ma active for two-wire passive pressure sensor 1 bit ±0.05 % of full scale 0.05 % per 10 K > 0 V (at 0 ma sensor current) General Supply Voltage 4 V DC, ±0 % Programming Interface via TRD 8001 or via interface RS485, USB (option) EMC according to EN and EN Power Consumption max. 4 W Dimensions see dimensional drawing (page 15) Electrical Connections Housing Material connectors M1 aluminum diecast Temperature ambient: : -40 C C [-40 F F] storage and transport: -40 C C [-40 F F] Protection Class Analog Output Current Output Resolution IP ma active 14 bit Linearity ±0.05 % Temperature Drift Load Output Value Pulse Output Frequency Range Output Signal Status In- and Output Status Output Control Input 0.05 % per 10 K < 800 Ω Note: For parameterization of the flow meter, the interface may be used. Prerequisite: Parameter setting is not allowed during active ESTA operation. programmable: flow, total, density, temperature ,000 Hz (for ESTA (OPTV receiver) 0.5-5,000 Hz) active push pull output for flow rate, optional: insulated optical frequency output push pull programmable (option) (in TOTAL mode: Hz) TRD 8001 REMOTE DISPLAY TECHNICAL DATA Display Supply Voltage Programming Interface to TCE programmable (standard: 1 input/option: inputs) option: insulated optical control input back-lit LCD screen, 13 x 3 dot via interface via front keyboard RS485 EMC according to EN and Dimensions see dimensional drawing (page 16) Electrical Connections Housing Material Protection Class Weight connectors M1 ABS-FR (plastic, flame retardant) IP kg [0.88 lb] Temperature operation: ±0 C C [3 F... + F] storage and transport: -0 C C [- 4 F F] Wall Mount hidden screws 10 11

7 035 TO TO L mm 0.87in G E D 70mm.76in L ID Y H H C 60mm.36in A B Sensor Type A D E G 6) H L 7) Y Sensor Type B C H L 8) I.D. Connection mm [8.43 in] M mm [0.59 in] G ½ 18 mm [7.17 in] mm [4.33 in] 16 mm [8.50 in], 61 mm [.40 in] 04 mm [8.03 in] 60 mm [10.4 in] mm [18.11 in] Ø 13 mm [Ø 0.51 in] on request 14 mm [8.43 in] M mm [0.59 in] G ½ 18 mm [7.17 in] mm [4.33 in] 16 mm [8.50 in] 08K 80 mm [3.15 in] 53 mm [9.96 in] 315 mm [1.40 in] 65 mm [4.61 in] Ø 3 mm [Ø 0.91 in] on request 151 mm [5.94 in] 387 mm [15.4 in] 480 mm [18.90 in] mm [3.68 in] Ø 40 mm [Ø 1.57 in] on request TO 30K L mm 0.87in G E D 70mm.76in 874mm 34.4in H A 59mm.3in 3mm 1.6in 974mm 38.37in 891mm 35.07in Y Sensor Type A D E G 6) H L 7) Y 350 mm [13.78 in] M mm [0.71 in] G ½ 80 mm [11.0 in] mm [5.51 in] 384 mm [15.1 in] 350 mm [13.78 in] M mm [0.71 in] G ½ 80 mm [11.0 in] mm [5.51 in] 384 mm [15.1 in] 704mm 7.73in 30mm 9.06in 1 6) Other connections on request. 7) Further lengths on request. 8) Further lengths on request. 13

8 METER-MOUNT ELECTRONICS TCE 8000/8100 METER-MOUNT ELECTRONICS TCE 8000/8100 WITH BLIND COVER 147mm 5.79in 03mm 7.99in 147mm 5.79in 184mm 7.4in mm 4.33in 166mm 6.5in mm 4.33in 166mm 6.5in 68mm.68in 118mm 4.65in 68mm.68in 99mm 3.90in WALL-MOUNT ELECTRONICS TCE 8000/8100 METER-MOUNT ELECTRONICS TCE 8000/8100 HIGH TEMPERATURE 147mm 5.79in 03mm 7.99in 147mm 5.80in 03mm 7.99in mm 4.33in 138mm 5.45in mm 4.3in 34mm 9.19in 10mm 0.39in 10,50mm 0.41in 116mm 4.57in 118mm 4.65in 68mm.68in 118mm 4.65in 14 15

9 STANDARD CONNECTION HEAD (A) PANEL-MOUNTED HOUSING 68mm.68in 115mm 4.5in 96mm 3.78in 143mm 5.64in 83mm 3.7in 88mm 3.45in 57mm.3in 96mm 3.78in 7mm.8in 96mm 3.80in 8mm 0.31in HIGH TEMPERATURE CONNECTION HEAD (H) METER-MOUNT ELECTRONICS TCE 6000 (F) 85mm 3.33in 105mm 4.14in 66mm.60in 46mm 1.81in 101mm 3.96in 77mm 3.01in 100mm 3.94in 63mm.48in 16 17

10 REMOTE DISPLAY TRD 8001 ORDERING CODE METER (TRICOR CLASSIC SERIES) XXXX - XX - X X X X - X X X X - Ex - XX 90mm 3.54in 10mm 4.7in 48mm 1.89in 16mm 0.63in Process Connections 9) see page 17 ff Mechanical Options Medium Temperature Range -40 C +100 C [-40 F +1 F] S -40 C +150 C [-40 F +30 F], Ex max : 135 C [75 F] H -40 C +70 C [-40 F +158 F], Ex, compact E -60 C +00 C [-76 F +39 F] T Pressure Range With rupture disc max. 4 bar [58 psi] Mechanical Design Standard Face to Face Length Standard (other length on request) Electronics Options Electronics Type Junction box, [316L] H Z Z S Meter mount, die cast aluminum housing for ½ NPT cable glands 10) C Meter mount, die cast aluminum housing for M0x1.5 cable glands 10) K Meter mount, stainless steel housing for ½ NPT cable glands 10) M Meter mount, stainless steel housing for M0x1.5 cable glands 10) O Meter mount electronics TCE ) F Interface 1) RS485 (Modbus RTU) RS485 (Modbus RTU) and HART RS485 (Modbus RTU) + FF (not with Ex) FF (Foundation Fieldbus ) RS485 (Modbus RTU) + USB (only TCE 6000) Not used Supply Voltage 4 V DC D V AC M Not used Options Pressure compensation, 4 0 ma input 8 pin I/O connector (TCE 6000 only) B Optical I/O (TCE 6000 only) No option EX-Protection ATEX + IECEx Zone1: Group IIC or IIB, T T4 ATEX Zone : II 3G Ex na IIC, T T4 Gc ccsaus: Class 1, Division 1: Group A, B, C, D or C, D, T T4 13) ATEX+IECEx: Zone 1: Group IIC or IIB, T T4 and ccsaus: Class 1, Division 1: Group A, B, C, D or C, D, T T413) 14) EAC (TR-CU): Group IIC or IIB, T T4 13) Special Options NOC (Net Oil Computer) 01 XX G S S S A B D F Z Z A C S Ex Exn Ex1 Ex3 ExR 18 9) For connections not indicated with installation length, please contact manufacturer. 10) For compact version with Ex-protection temperature class T4 only. 11) Ex-protection only available in the option Exn. TCE 6000 electronic is not applicable for 30K. 1) Other interfaces on request. 13) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing. 14) Only with remote electronics. 19

11 ORDERING CODE TCE TRANSMITTER (SERIES 8XXX) Housing material: Aluminum 8 0 Housing material: stainless steel [AISI 316L] 8 1 Electronics for 035 to 0 1 Electronics for 08K to 1 1 Electronics for 30K 1 Housing Wall mount (housing for ½ NPT cable glands) Wall mount (housing for M0x1.5 cable glands) Panel mount 15) Panel mount, wide, for "Ex", "associated equipment" 15) Options Interface 16) RS485 (Modbus RTU) R485 (Modbus RTU) + HART TCE 8 X X X - X - X X X X - XX - XX Supply Voltage 4 V DC V AC (only housing S+L) B 4 V DC D V AC (only housing W, I) M Electronic Options Standard S Pressure compensation, 4 0 ma input A Cable Length 3 Meters [ 10 ft.], Standard (high temperature) S (H) 6 Meters [ 0 ft.] (high temperature) B (I) 10 Meters [ 33 ft.] (high temperature) C (J) 15 Meters [ 49 ft.] (high temperature) D (O) 0 Meters [ 65 ft.] (high temperature) 3 Meters [ 10 ft.], offshore cable E (P) F D-SUB Connector, (housing L+S) seperate cable required Ex-Protection ATEX + IECEx Zone1: Group IIC or IIB, T T4 ATEX Zone : II3G Ex na IIC, T T4 Gc ccsaus: Class 1, Division 1: Group A, B, C, D or C, D, T T4 17) ATEX+IECEx, Zone 1: Group IIC or IIB, T T4 and ccsaus: Class 1, Div. 1: Group A, B, C, D or C, D, T T4 17) EAC (TR-CU): Group IIC or IIB, T T4 17) Special Options NOC (Net Oil Computer) 01 W I S L S A N Ex Exn Ex1 Ex3 ExR TRICOR CONNECTION CABLE (TCC) FOR PANEL-MOUNTED HOUSING Cable Specifications/Connections TCC X X - X X Cable Connector TCE Connector Devices Standard cable SUB-D, 9-pin cable end sleeves (8-pol.) TCE 8**1-S- 0 TCE 8**1-L- Standard cable SUB-D, 9-pin/ cable end sleeves (8-pol.) TCE 8**1-S- 0 4 Din-Rail mounting TCE 8**1-L- High temperature cable SUB-D, 9-pin cable end sleeves (8-pol.) TCE 8**1-S- 0 9 TCE 8**1-L- High temperature cable SUB-D, 9-pin/ cable end sleeves (8-pol.) TCE 8**1-S- 1 0 Din-Rail mounting TCE 8**1-L- Length 3 meter (Standard) [ 10 ft.] meter [ 0 ft.] meter [ 33 ft.] meter [ 49 ft.] meter [ 66 ft.] 0 ADDITIONAL ACCESSORIES Accessories for TCE 8* electronic USB interface cable to RS485, 1.8 m (TRICOR configurator) Model CON.USB.RS-ISO IP65 Protection for TCE-80**-L IPS 9-14 IP65 Protection for TCE-80**-S IPS 9-9 Adapter TCE-80**-S and TCE-80**-L for rail mounting HSA 96 Accessories for TCE 6000 electronic Model Remote display for TCE 6000 TRD 8001 Connection cable TRD 8001 to TCE 6000, m Connection cable TRD 8001 to TCE 6000, 5 m USB Cable, USB to mini USB M1, m RS485 to USB connector cable 3 m for TCE 6000; versions FSDS;FFDB, FSDC Pneumatic Power Gen. Plug M8, 3 pin,.5 m cable for TCE 6000 Version FSDC; 7.5 W, 4 V DC Light pulse emitter and receiver, DIN-rail for TCE 6000 Version FSDC Fiber optic cable for TCE 6000 Version FSDC for FOP 50/60, 10 m (5.5 mm) Service and calibration DAkkS-Calibration (ILAC) according to DIN EN ISO/IEC 1705:005 Oxygen cleaning Inspection certificate 3.1 according to DIN /EN 1004 TAG Plate [AISI 316L] TRD-TCE-6- TRD-TCE-6-5 KAB-USB-TCE KAB-RS485-TCE-ISO TCE 6000-FSDC-SET-PPG OPTV-0/XO LW-LA-10 Model DAkkS-Kalibrierung Reinigung Sauerstoff 3.WKZ Tag-Plate ) Only for TCE 80XX. 16) Other interfaces on request. 17) For Ex1, Ex3, EAC (TR-CU) the electronic is only available in aluminum housing. 1

12 SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. ANSI B16.5 SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. ANSI B16.5 Process connection 18) K 30K Process connection 19) K 30K ½ ANSI flange class 150 AA ANSI flange class 150 AN 65 [4.61] [3.68] ½ ANSI flange class 300 AB ANSI flange class 300 AO 65 [4.61] [3.68] ½ ANSI flange class 600 AC ANSI flange class 600 AP 65 [4.61] [3.68] ½ ANSI flange class 900 AD ANSI flange class 900 AR 65 [4.61] [3.68] ½ ANSI flange class 1500 BV ANSI flange class 1500 BU [3.68] ½ ANSI flange class 500 BE ½ ANSI flange class 150 BT [3.68] ¾ ANSI flange class 150 BA ½ ANSI flange class 300 BY [3.68] ¾ ANSI flange class 300 BB ½ ANSI flange class 600 BQ [3.68] ¾ ANSI flange class 600 BC ½ ANSI flange class 900 BW [3.68] ¾ ANSI flange class 900 BD ¾ ANSI flange class 1500 AI ANSI flange class 150 AS 3 ANSI flange class 300 AT 65 [4.61] [3.68] [3.68] [36.0] [36.0] 1 ANSI flange class 150 AE [4.61] 3 ANSI flange class 600 AU [3.68] [36.0] 1 ANSI flange class 300 AF [4.61] 3 ANSI flange class 900 AV [3.68] [36.0] 1 ANSI flange class 600 AG 1 ANSI flange class 900 AH 1 ANSI flange class 1500 AQ 1 ANSI flange class 500 BN [4.61] 65 [4.61] 4 ANSI Flange class 150 AW 4 ANSI flange class 300 AX 4 ANSI flange class 600 AY 4 ANSI flange class 900 AZ [3.68] [3.68] [3.68] [3.68] [36.0] [36.0] [36.0] [36.0] 1½ ANSI flange class 150 AJ 1½ ANSI flange class 300 AK 1½ ANSI flange class 600 AL 1½ ANSI flange class 900 AM 1½ ANSI flange class 1500 BI 65 [4.61] 65 [4.61] 65 [4.61] 65 [4.61] 5 ANSI flange class 150 BF 5 ANSI flange class 300 BG 5 ANSI flange class 600 BH 5 ANSI flange class 900 BJ [36.0] [36.0] [36.0] [36.0] 6 ANSI flange class 150 BM [36.0] 6 ANSI flange class 600 BX [36.0] 18) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 19) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 3

13 SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN FORM B SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN FORM B Process connection 0) K 30K Process connection 1) K 30K DN 10, EN flange PN 40 DS DN 40, EN flange PN 40 DE 65 [4.61] DN 10, EN flange PN 63 DZ DN 40, EN flange PN 63 EK 65 [4.61] DN 10, EN flange PN 100 EA DN 40, EN flange PN 100 DF 65 [4.61] DN 10, EN flange PN 160 EB DN 40, EN flange PN 160 EL DN 10, EN flange PN 50 EC DN 40, EN flange PN 50 EM DN 10, EN flange PN 400 ED DN 40, EN flange PN 400 EN DN 15, EN flange PN 40 DA DN 50, EN flange PN 16 EO 65 [4.61] [3.68] DN 15, EN flange PN 63 EF DN 50, EN flange PN 40 DG 65 [4.61] [3.68] DN 15, EN flange PN 100 DB DN 50, EN flange PN 63 EP 65 [4.61] [3.68] DN 15, EN flange PN 160 EG DN 50, EN flange PN 100 DH 65 [4.61] [3.68] DN 15, EN flange PN 50 DN 15, EN flange PN 400 EH EI DN 65, EN flange PN 16 DN 65, EN flange PN 40 EQ DQ [3.68] [3.68] DN 0, EN flange PN 40 DT DN 65, EN flange PN 63 ER [3.68] DN 5, EN flange PN 40 DC [4.61] DN 65, EN flange PN 100 ES [3.68] DN 5, EN flange PN 63 EJ [4.61] DN 80, EN flange PN 16 ET [3.68] [36.0] DN 5, EN flange PN 100 DD [4.61] DN 80, EN flange PN 40 DJ [3.68] [36.0] DN 5, EN flange PN 160 DW DN 80, EN flange PN 63 EU [3.68] [36.0] DN 5, EN flange PN 160 Mat.:. DW 65 [4.61] DN 80, EN flange PN 100 DK [3.68] [36.0] DN 5, EN flange PN 50 DN 5, EN flange PN 400 DP DV DN 100, EN flange PN 16 DN 100, EN flange PN 40 EV DL [3.68] [3.68] [36.0] [36.0] DN 3, EN flange PN 40 DR 65 [4.61] DN 100, EN flange PN 63 EW [3.68] [36.0] DN 100, EN flange PN 100 DM [3.68] [36.0] 4 0) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 1) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 5

14 SLIP ON, PROCESS CONNECTION DIM. + FACING ACC. EN FORM B FEMALE THREAD Process connection ) DN15, EN flange PN 16 DN15, EN flange PN 40 DN15, EN flange PN 63 DN15, EN flange PN 100 EX DN EY DO K 30K [36.0] [36.0] [36.0] [36.0] Process connection 3) ¼ NPT female thread FJ ¾ NPT female thread FL ½ NPT female thread FK NPT female thread FQ K 880 [34.65] 30K DN150, EN flange PN 16 DN150, EN flange PN 40 DI DX [36.0] [36.0] ¼ G. female thread FB ⅜ G, female thread FR ¾ G, female thread FC EN FLANGE WELD NECK ½ G, female thread FA Process connection ) K 30K DN 3, PN40 DIN [AISI 316L] Type C Face VO 65 [4.61] DN 3, PN64 DIN [AISI 316L] Type E Face VP 65 [4.61] DN 3, PN100 DIN [AISI 316L] Type E Face VQ 65 [4.61] TRICLAMP Process connection ) K 30K ½ Triclamp TA 0 [8.66] 0 [8.66] 50 [9.84] 50 [9.84] DN 5 Triclamp PN 16 DIN 3676 TL 10 [8.7] 10 [8.7] 40 [9.45] 40 [9.45] 65 [4.61] 6 ) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 3) Connections without installation length are not possible or need manufacturer release. Please contact the manufacturer. 7

15 Contact N & S AMERICA AW-Lake Company 440 W. Corporate Preserve Dr. #600 Oak Creek WI USA ASIEA/PACIFIC, MIDDLE EAST KEM Instruments SEA Pte. Ltd. 1 Magazine Road #04-01 Central Mall Office Tower Singapore CHINA KEM flow technology (Beijing) Co., Ltd. Rm. 906, Block C, Ruipu Office Bldg, No. 15 HongJunYingNan Road Chaoyang District, Beijing China REST OF WORLD KEM Küppers Elektromechanik GmbH Liebigstraße Karlsfeld Germany Original KEM/AWL Dokument: _E68_CLASSIC_D_EN_18070_E005 I Copyright KEM/AWL, Subject to change without notice