CLIENT NAME: REGIONAL DISTRICT OF NORTH OKANAGAN 9848 ABERDEEN ROAD COLDSTREAM, BC V1B2K9 (250) ATTENTION TO: Keiko Parker

Size: px
Start display at page:

Download "CLIENT NAME: REGIONAL DISTRICT OF NORTH OKANAGAN 9848 ABERDEEN ROAD COLDSTREAM, BC V1B2K9 (250) ATTENTION TO: Keiko Parker"

Transcription

1 9848 ABERDEEN ROAD COLDSTREAM, BC V1B2K9 (250) SOIL ANALYSIS REVIEWED BY: Andrew Garrard, B.Sc., General Manager DATE REPORTED: Mar 09, 2016 PAGES (INCLUDING COVER): 12 VERSION*: 1 Should you require any information regarding this analysis please contact your client services representative at (778) *NOTES VERSION 1: Sample receipt temperature 1 C. All samples will be disposed of within 30 days following analysis. Please contact the lab if you require additional sample storage time. Laboratories (V1) Page 1 of 12 Member of: Association of Professional Engineers, Geologists and Geophysicists of Alberta (APEGGA) Western Enviro-Agricultural Laboratory Association (WEALA) Environmental Services Association of Alberta (ESAA) AGAT Laboratories is accredited to ISO/IEC by the Canadian Association for Laboratory Accreditation Inc. (CALA) and/or Standards Council of Canada (SCC) for specific tests listed on the scope of accreditation. AGAT Laboratories (Mississauga) is also accredited by the Canadian Association for Laboratory Accreditation Inc. (CALA) for specific drinking water tests. Accreditations are location and parameter specific. A complete listing of parameters for each location is available from and/or The tests in this report may not necessarily be included in the scope of accreditation. All reportable information as specified by ISO 17025:2005 is available from AGAT Laboratories upon request

2 DATE RECEIVED: Parameter Unit SAMPLE DESCRIPTION: SAMPLE TYPE: DATE SAMPLED: G / S RDL Aluminum µg/g 10 Arsenic µg/g 0.1 Cadmium µg/g 0.01 Chromium µg/g 1 Cobalt µg/g 0.1 Copper µg/g 0.2 Lead µg/g 0.1 Mercury µg/g 0.01 Molybdenum µg/g 0.2 Nickel µg/g 0.5 Phosphorus µg/g 5 Selenium µg/g 0.1 Zinc µg/g 1 ph 1:2 ph units 0.1 Comments: RDL - Reported Detection Limit; G / S - Guideline / Standard Results are based on the dry weight of the sample #1 Compost Certificate of Analysis British Columbia Metals Schedule 4 and 5 #2 Compost 2/29/2016 2/29/ DATE REPORTED: CERTIFICATE OF ANALYSIS (V1) Certified By: Page 2 of 12

3 DATE RECEIVED: C:N Ratio Parameter Unit SAMPLE DESCRIPTION: SAMPLE TYPE: DATE SAMPLED: G / S RDL Nitrogen - Total % 0.02 Organic Carbon-Total % 0.02 Comments: RDL - Reported Detection Limit; G / S - Guideline / Standard #1 Compost Certificate of Analysis #2 Compost 2/29/2016 2/29/ C:N Ratio DATE REPORTED: CERTIFICATE OF ANALYSIS (V1) Certified By: Page 3 of 12

4 DATE RECEIVED: Parameter Unit SAMPLE DESCRIPTION: SAMPLE TYPE: DATE SAMPLED: G / S RDL Available Ammonium (NH4 - N) mg/kg 1 Organic Matter by Loss on Ignition % 0.3 Comments: RDL - Reported Detection Limit; G / S - Guideline / Standard * Analysis performed at AGAT Laboratories Calgary. #1 Compost Certificate of Analysis #2 Compost 2/29/2016 2/29/ Analysis - Organic Matter (LOI) / Ammonium DATE REPORTED: CERTIFICATE OF ANALYSIS (V1) Certified By: Page 4 of 12

5 DATE RECEIVED: Parameter Unit SAMPLE DESCRIPTION: SAMPLE TYPE: DATE SAMPLED: G / S RDL Total Organic Carbon % 0.15 Fraction Organic Carbon in Comments: RDL - Reported Detection Limit; G / S - Guideline / Standard * Analysis performed at AGAT Laboratories Calgary. #1 Compost Certificate of Analysis #2 Compost 2/29/2016 2/29/ Analysis - Total Organic Carbon (W-B Wet Oxidation) DATE REPORTED: CERTIFICATE OF ANALYSIS (V1) Certified By: Page 5 of 12

6 DATE RECEIVED: Parameter Unit SAMPLE DESCRIPTION: SAMPLE TYPE: DATE SAMPLED: G / S RDL ph (Saturated Paste) ph units 0.1 Electrical Conductivity (Saturated Paste) ms/cm 0.01 Saturation Percentage % Comments: RDL - Reported Detection Limit; G / S - Guideline / Standard #1 Compost Certificate of Analysis ph, Electrical Conductivity - Saturate Paste #2 Compost 2/29/2016 2/29/ DATE REPORTED: CERTIFICATE OF ANALYSIS (V1) Certified By: Page 6 of 12

7 Quality Assurance Analysis RPT Date: DUPLICATE REFERENCE MATERIAL METHOD BLANK SPIKE MATRIX SPIKE PARAMETER Batch Sample Id Dup #1 Dup #2 RPD Method Blank Measured Value Acceptable Limits Lower Upper Acceptable Limits Recovery Lower Upper Acceptable Limits Recovery Lower Upper British Columbia Metals Schedule 4 and 5 Aluminum % < % 70% 130% 99% 90% 110% Arsenic % < % 70% 130% 100% 90% 110% Cadmium % < % 70% 130% 99% 90% 110% Chromium % < 1 110% 70% 130% 106% 90% 110% Cobalt % < % 70% 130% 103% 90% 110% Copper % < % 70% 130% 105% 90% 110% Lead % < % 70% 130% 98% 90% 110% Mercury % < % 70% 130% 91% 90% 110% Molybdenum % < % 70% 130% 102% 90% 110% Nickel % < % 70% 130% 106% 90% 110% Phosphorus % < 5 105% 70% 130% 94% 85% 115% Selenium % < % 90% 110% Zinc % < 1 108% 70% 130% 109% 90% 110% ph 1: % < % 90% 110% 100% 95% 105% Comments: RPDs are calculated using raw analytical data and not the rounded duplicate values reported. ph, Electrical Conductivity - Saturate Paste ph (Saturated Paste) % < % 80% 120% Electrical Conductivity (Saturated % < % 80% 120% Paste) Saturation Percentage % < 100% 80% 120% C:N Ratio Nitrogen - Total % < % 80% 120% Analysis - Total Organic Carbon (W-B Wet Oxidation) Total Organic Carbon % < % 80% 120% 91% 80% 120% Comments: If Matrix spike value is NA, the spiked analyte concentration was lower than that of the matrix contribution. If the RPD value is NA, the results of the duplicates are under 5X the RDL and will not be calculated. Analysis - Organic Matter (LOI) / Ammonium Available Ammonium (NH4 - N) % < 1 92% 80% 120% 100% 80% 120% 103% 80% 120% Organic Matter by Loss on Ignition % < 0.3 NA 80% 120% NA 80% 120% Certified By: QUALITY ASSURANCE REPORT (V1) Page 7 of 12 AGAT Laboratories is accredited to ISO/IEC by the Canadian Association for Laboratory Accreditation Inc. (CALA) and/or Standards Council of Canada (SCC) for specific tests listed on the scope of accreditation. AGAT Laboratories (Mississauga) is also accredited by the Canadian Association for Laboratory Accreditation Inc. (CALA) for specific drinking water tests. Accreditations are location and parameter specific. A complete listing of parameters for each location is available from and/or The tests in this report may not necessarily be included in the scope of accreditation.

8 Analysis Aluminum Arsenic Cadmium Chromium Cobalt Copper Lead Mercury Molybdenum Nickel Phosphorus Selenium Zinc ph 1:2 PARAMETER MET , MET , INOR Method Summary AGAT S.O.P EPA 6010C EPA 6010C BC MOE Lab Manual B (ph, Electrometric, ) LITERATURE REFERENCE ANALYTICAL TECHNIQUE ICP/OES ICP/OES PH METER C:N Ratio Nitrogen - Total INOR Modified from ASTM E COMBUSTION Available Ammonium (NH4 - N) SOIL 0630, INST 0420 SM 4500-NH3 G DISCRETE ANALYZER Organic Matter by Loss on Ignition SOIL 470 McKeague 3.81 COMBUSTION Total Organic Carbon SOIL 0480; SOIL 0110; SOIL NELSON 1996; SHEPPARD SPECTROPHOTOMETER ph (Saturated Paste) LAB BC MOE Lab Manual Section B PH METER Electrical Conductivity (Saturated Paste) LAB BC MOE Lab Manual Section B CONDUCTIVITY METER Saturation Percentage LAB BC MOE Lab Manual Section B GRAVIMETRIC METHOD SUMMARY (V1) Page 8 of 12

9 Page 9 of 12

10 Page 10 of 12

11 Page 11 of 12

12 Page 12 of 12