Schedule of Accreditation

Size: px
Start display at page:

Download "Schedule of Accreditation"

Transcription

1 As an accredited laboratory, this laboratory is entitled to use the following accreditation symbol. Valid from 27 April 24 to 26 April 27 Issued on 15 August 24 Schedule of Accreditation Accreditation Scheme for Testing / Calibration Laboratories Sri Lanka Accreditation Board for Conformity Assessment Accreditation Number: CL Calibration Laboratory SGS Lanka (Pvt) Ltd.48/1, James Peries Mawatha, Colombo 02. ISO/ IEC CL 003- Scope of Accreditation: Mechanical calibration of Calipers (Vernier, Digital & Dial), Micrometers, Circular Sample Cutters (Fabric & Paper), Calibration of Volumetric Glassware (Burettes, Single volume Pipettes, Graduated Pipettes, Measuring Cylinders & Measuring Flasks, Calibration of n- automatic Weighing Instruments ( Analytical Balances, Digital Electronic Top loading Balances, Analogue and Digital Weighing Scales, Spring Balances, Triple Beam Balances and Push pull gauges) Thermal calibration of Temperature Chambers up to three points (Ovens, Incubators, Dryers, Muffle & Tube Furnaces, Auto Clave and Liquid Baths), digital thermo meter together with sensors, Analogue Thermometer together with a sensor and Dial thermometer per the calibration methods appearing in this schedule. The laboratory is accredited for the following calibrations and details are given page two onwards. Page of 06

2 Quantity/ Instrument or Gauge CMC expressed as Expanded Uncertainty (k=2) Mechanical Calibration ( Length & Volume) Calibration of Vernier Calipers Digital Calipers Dial Calipers ISO :21 ( Part & 02) 0 mm 300 mm 0 mm 600 mm 0.0mm mm 0.mm mm 0.1mm mm 0. mm mm 0.1 mm mm 02 Calibration of Micrometer ISO 3611: 20 0 mm to 2000 mm 0.02 mm mm 0 mm 25 mm 0.0 mm mm 0 mm 300mm 0. mm mm 0 mm mm 0.02 mm 0.4 mm 03 Calibration of Circular Fabric Sample Cutter and Circular Paper Sample Cutter LCAL/TM /SOP/08: Rev 02 0 mm 300 mm NA 0.56 mm 04 Calibration of Volumetric Glassware Burettes Up to 80 ml NA 0.21 μl Single volume Pipettes Up to 80 ml NA 0.21 μl Graduated pipettes LCAL/TM/SOP/06: Rev 06 Up to 80 ml NA 0.21 μl Measuring Cylinders Up to 80 ml NA 0.21 μl 80 ml to 200 ml NA 0.30 μl 100 ml to 200 ml NA 0.55 μl Measuring Flasks Up to 80 ml NA 0.21 ml 80 ml to 200 ml NA 0.30 μl 100 ml to 200 ml NA 0.55 μl Page 02 of 06

3 Quantity/ Instrument or Gauge Method of Calibration Range Readability / CMC expressed as Expanded Uncertainty (k=2) Mechanical Calibration ( Mass) Calibration of n Automatic Weighing Instruments. (Analytical Balances, Digital Electronic Top loading Balances, Analogue Top Loading Balances, Analogue and Digital weighing scales, Spring balances, Triple beam balances and Push pull gauges.) LCAL/TM/ SOP-15 Rev g 0.1 mg 0.21 mg 1 mg 0.62 mg 0.1 mg 0.29 mg External /inhouse Up to 300 g. 1 mg 0.65 mg Up to 500 g. 0.1 mg 0.66 mg On-site 1 mg 0.74 mg External /inhouse 10 mg g Up to 600 g 1 mg 0.74 g Page 03 of 06

4 Quantity/ Instrument or Gauge CMC expressed as Expanded Uncertainty (k=2) Mechanical Calibration ( Mass) Calibration of n Automatic Weighing Instruments. (Analytical Balances, Digital Electronic Top loading Balances, Analogue Top Loading Balances, Analogue and Digital weighing scales, Spring balances, Triple beam balances and Push pull gauges.) LCAL/TM/SOP-15 Rev.00 Up to 1000 g 5 g 2.9 g On-site /Inhouse Up to 5000 g 10 mg g 5 g 2.9 g Up to g 5 g 2.9 g Up to 55 kg. 5 g 2.9 g Page 04 of 06

5 Quantity/ Instrument or Gauge CMC expressed as Expanded Uncertainty (k=2) Thermal Calibration (Calibration of Temperature Chambers -Three set points ) LCAL/TM/SOP-- Rev C 200 C NA 0.40 C Chamber 200 C 600 C NA 0.51 C Oven LCAL/TM/SOP-- Rev C 200 C NA 0.40 C ( Single site, three 200 C 600 C NA 0.51 C site and multisite) Incubator LCAL/TM/SOP-- Rev 07 ( Single site, three 0 C 90 C NA 0.24 C 02 site and multisite) Dryer LCAL/TM/SOP-- Rev C 600 C NA Liquid Bath LCAL/TM/SOP-- Rev C to -20 C -20 C to 80 C NA 0.3 C 80 C 240 C 0.7 C Industrial Retorts LCAL/TM/SOP-- Rev C 150 C NA 1.23 C Calibration of Muffle/ Tube Furnaces 0.40 C 0.1 C LCAL/TM/SOP-3 Rev to C NA 1.1 C C to C NA 2.2 C 03 Performance Test of Auto Clave C to C NA 2.3 C LCAL/TM/SOP-4 Rev C to 150 C NA 0.22 C Calibration Of Digital Thermometer together with a Sensor Calibration of Analogue Thermometer together with a Sensor LCAL/TM/SOP-1 Rev C to 140 C 140 C to 660 C LCAL/TM/SOP-2 Rev C to 140 C 140 C to 660 C 0.0 C 0. C 0. C 0. C 0.05 C 0.03 C 0.5 C 0.29 C 1 C 0.58 C 0.0 C C 0. C 0.05 C 0.05 C 0.05 C 0.5 C 0.18 C 1 C 0.34 C 0.0 C 0. C 0. C 0. C 0.05 C 0.03 C 0.5 C 0.29 C 1 C 0.58 C 0.0 C 0.05 C 0. C 0.05 C 0.05 C 0.05 C 0.5 C 0.18 C 1 C 0.34 C Page 05 of 06

6 Quantity/ Instrument or Gauge Thermal Calibration CMC expressed as Expanded Uncertainty (k=2) 06 Calibration of Dial Thermometer LCAL/TM/SOP-0 Rev C to 140 C 0.0 C 0. C 0. C 0. C 0.05 C 0.03 C 0.5 C 0.29 C 1 C 0.58 C 140 C to 660 C 0.0 C 0.05 C 0. C 0.05 C 0.05 C 0.05 C 0.5 C 0.18 C 1 C 0.34 C 07 Calibration of Microwave oven LCAL/TM/TE Rev 700 W NA 2.90 W te: Readability/ resolution values and CMC values have been calculated as per best existing devices and the use of different references for the calibration. Director /CEO Sri Lanka Accreditation Board for Conformity Assessment Page 06 of 06