1 Corrosion characteristics of mild steel storage tanks in fluorine-containing acid by R. van der Merwe*, L.A. Cornish* and J.W. van der Merwe* The hydrofluoric acid (HF) industry in South Africa uses normalized mild steel (SA 516 Gr 70) for the storage and distribution of its technical-grade product (70% HF). The technical-grade acid is split from the anhydrous hydrogen fluoride (AHF) product during distillation just after HF is produced, in a stainless-steel-lined kiln, from the reaction of calcium fluoride (CaF 2 ) with sulphuric acid (H 2 SO 4 ). Uniform corrosion of the storage tanks is mitigated during commissioning by contacting the steel with 70% HF. A corrosive reaction takes place (2H + + 2F - + Fe H 2 + FeF 2 ) to form scale inside the tank which diminishes the attack of the steel by fresh HF, thus prolonging the service life expectancy of the vessels. This iron fluoride scale in the vessel grows continually, resulting in corrosion of the vessels continuing at a predictable rate (approx. 0.5 mm/a) since the first commissioning of the tanks at Necsa in In early 2012, an increase in the average corrosion rate of the tanks to 3 mm/a measured at and below the liquid band in the storage vessels was noted. Three months later the corrosion rate had increased to 30 mm/a, just before the first leak from the tank was detected. The tanks were decommissioned shortly afterwards and an investigation revealed that the rapid corrosion was due to the presence of increased levels (>50 ppm) of nitric acid (HNO 3 ) in the tanks, which attacked the fluoride layer protecting the steel. The oxidation characteristics of high concentrations of HNO 3 with low concentrations of HF on stainless steel surface treatment are well documented. The effects of low levels of nitric acid on the corrosion of steels in sulphuric acid are also known, but no suitable published data currently exists on corrosion by high HF concentrations with low HNO 3 concentrations. Establishing the rate and mechanism of corrosion by HNO 3 (0.1 to 1%) in 70% HF is currently a high priority for the HF industry in South Africa and will become increasingly important in the near future due to depleting fluorite reserves and cheaper, but less efficient, processes producing H 2 SO 4 with higher impurity levels, which were not anticipated in the original plant design. The aim of this study is to simulate the corrosion conditions in the plant on a laboratory scale in order to establish the corrosion characteristics of the steels used in the HF plant, which are increasingly exposed to the HNO 3 impurities that tend to concentrate in the final technical-grade HF acid product. inspections so that the service life can be safely anticipated. However, despite the regular inspections and current contingencies in the HF plant at Necsa, an isolated case of HF leakage from two mild steel vessels during operation occurred without warning (Valkenburg, 2012). The failure of both these vessels necessitated their premature decommissioning and uncovered a real need to understand the corrosion characteristics of mild steel used in the HF industry and recommend corrosion design improvements. The reason for the failure of the mild steel was traced to an excess of nitric acid (HNO 3 ) in the feedstock to the plant, which eventually concentrated in the technical-grade HF product downstream. The combined corrosion effect of HF and HNO 3 in the storage tanks led to their premature failure. A study to simulate the corrosion conditions in the laboratory was required to better estimate the service life of the steels used in the HF plant. Understanding the effect of HNO 3 contamination on the plant s steels and the determination of corrosion inhibition strategies was essential. Laboratory immersion experiments were required to establish the corrosion characteristics of the mild steel used in a HF plant, which could be exposed to >50 ppm HNO 3 impurities. Neither published, nor quantitative, corrosion data on the corrosiveness of HF in the presence of an oxidizing agent were available at the time of the failure of the two technical-grade HF hydrofluoric acid, mild steel, corrosion, nitric acid contamination. Mild steel is a relatively inexpensive material that is often effectively used for the storage and distribution of technical-grade hydrofluoric acid (70% HF). Uniform corrosion of HF storage tanks is inevitable and typically reaches 0.5 mm/a (Valkenburg, 2012). The thickness of the steel is regularly monitored ultrasonically and documented during * School of Chemical and Metallurgical Engineering, University of Witwatersrand, Johannesburg and DST- NRF Centre of Excellence in Strong Materials, hosted by the University of the Witwatersrand. Applied Chemistry Department, South African Nuclear Energy Corporation SOC Limited (Necsa). The Southern African Institute of Mining and Metallurgy, ISSN This paper was first presented at the AMI Ferrous and Base Metals Development Network Conference October 2016, Southern Sun Elangeni Maharani, KwaZulu-Natal, South Africa. VOLUME

2 storage tanks at Necsa (Valkenburg, 2012). In the absence of data, to understand the effects of the different concentrations and combinations of HF and HNO 3, the only option was to reproduce the unique corrosive environment in a laboratory. The initial step was to develop a safe method for conducting immersion corrosion tests using chemically pure HF. The results from these experiments would then be used as a reference to compare the findings from future corrosion tests where HNO 3 contamination was introduced. Moreover, these laboratory tests would serve to establish whether the approach used was suitable for predicting the corrosion rates of the steel tanks and components in the plant in its present condition. To determine the necessary duration of typical HF corrosion tests, planned interval corrosion tests (PICTs), as prescribed by Wachter and Treseder in ASTM Standard G31-72 (2004), needed to be conducted safely. This work has been reported elsewhere (van der Merwe, Cornish and van der Merwe, 2016). Since safety implications when working with fuming HF (>60% HF) were a concern, initially the PICTs were used to establish the lowest HF concentration at which laboratory-scale tests could be conducted, while producing corrosion data that could be related to the corrosive conditions experienced in industry. Next, corrosion tests using the most suitable conditions could continue in which the effect of HNO 3 concentration would be the focus. However, the effect of HF concentration on mild steel corrosion was also accessible from the PICT results, which showed that varying corrosion forms and mechanisms occur at different HF concentrations. These results differed somewhat from published data (Craig and Anderson, 1994; Hansen and Puyear, 1996; Honeywell, 2002) and were therefore examined further in this study. The material was a mild steel (SA 516 Gr 70), used as construction material for 70% HF storage tanks. The steel was initially hot-rolled to a thickness of 3 mm, then cut with a waterjet to produce coupons sized mm. A 7 mm hole was cut in the middle of each coupon, which effectively produced a surface area of cm 2. Therefore, a total of four coupons would be allowed to hang from the corrosion rack during a 500 ml experiment, effectively exceeding the minimum ASTM target requirement of 30 ml/cm 2 per immersion experiment (Baboian, 2005). Coupons were sandblasted and washed with acetone to remove mill scale prior to each experiment. All coupons were pre-passivated in HF for 24 hours at 25 C prior to each PICT. Pre-passivation was done to produce the protective scale layer essential for the use of mild steel in the HF industry (Jennings, 2007). The HF used for the PICTs was aqueous hydrogen fluoride (70% industrial grade) collected from the Pelchem SOC Ltd fluorochemical plant, situated on the site at Necsa. The 70% HF was a high-quality product (fluorosilicic acid 100 ppm, sulphuric acid 200 ppm and nitric acid <5 ppm) received in sealed 25 L bottles, which were intended for export by Protea Chemicals (Inland). The lower concentration HF solutions (40% and 48%) were analytical grade ([NO 3 - ] <5 ppm) solutions purchased from Merck (Pty) Ltd. Corrosion solutions were analysed at Pelindaba Analytical Laboratories (PAL) using volumetric titrations and inductively coupled plasma optical emission spectrometry (ICP-OES) to determine HF and metal concentrations in corrosion solution products. Each experiment was conducted in a 500 ml Teflon bottle which was placed in a water bath to maintain the acid at a constant temperature while corrosion of the coupons took place (Figure 1a). The coupons were assembled into a cylindrical rack (made of Teflon) which was placed upright in the bottle (Figure 1b). The HF was then poured into the bottle until the cylindrical rack holding the coupons (Figure 1c) had been completely covered. The bottle lid, with the 2 mm diameter drilled hole, was then screwed on. This allowed for the release of HF fumes in order to avoid pressure build-up in the Teflon container. The temperature was maintained at 25 C using an immersion cooler attached to the polypropylene lid, custom-made to cover the bath and which allowed the immersion cooler to hang freely in the water while being shielded from HF fumes by a polypropylene cylinder attached to the lid (Figure 1a). The lid over the water bath had a release valve in the open position, which channelled any HF fumes from the corrosion reaction to the extraction line of the fume cupboard, which led out to the KOH scrubber. 922 VOLUME 116

3 PICTs were allowed to run for periods of time experimentally determined by the planned interval tests of Wachter and Treseder in ASTM Standard G (ASTM, 2009). Four coupons per bottle were introduced to a maximum of 500 ml HF. Subsequently, one coupon was removed from the corrosion rack at a specified time; this continued over the entire duration of a corrosion experiment, until all coupons had been removed. This was done to establish the metal samples susceptibility to corrosion, the liquid s corrosiveness and the rate of the corrosion reaction under the simulated conditions. Following this standard method, the fourth coupon (B) was placed into the HF corrosion solution at the same time that the second coupon (A t ) was removed and allowed to corrode with the third coupon (A t + 1 ) for the remaining four days. In this way, comparing the corrosion rate measured for coupons 3 and 4, a change in the liquid corrosiveness could be compared to the criteria set out in the ASTM practice. In the same way, the susceptibility of the mild steel to the HF corrosion solution was determined by comparing the corrosion rate determined for coupon B to that of coupon A 2 (Tables I III). The mass loss for coupon A 2 was determined by subtracting the mass losses of coupons A t and A t-1 and the corrosion rate determined using the average density of the coupons in that batch (e.g. coupon 1 4 in Table I). Each time a coupon was removed from the bottle, it was rinsed with water and air-dried before storage in a desiccator. After testing, the corrosion products were removed from the coupons by ultrasonic cleaning for 30 minutes, followed by mechanical cleaning with a steel brush to ensure complete removal of the scale from the coupon prior to weighing. To calculate the corrosion rate (CR) in mm/a from metal loss the following equation was used: CR = 87.6 x (W/ At) [1] where W = weight loss (in mg), = density (in g/cm 3 ), A = area (in cm 2 ) of the coupons exposed to HF over time (in hours) based on ASTM Standard G31-72 (2004). The convention is to measure corrosion rate in mils penetration per year (MPY) (Jones, 1996). However, the constant (in this case K = 87.6) is dimensionless and changes with the conversion to the desired unit (in this case mm/a) (Davis and ASM International, 2000). In the PICTs, identical coupons were placed in the same HF solution in the 500 ml Teflon bottle. The temperature was kept constant at 25ºC for the entire time (t + 1). The symbols A 1, A t, A t+1 and B were used to represent the corrosion damage experienced in each test (ASTM, 2009). Subsequently, A 2 was calculated by subtracting A t from A t +1. The data collected from the tests at different HF concentrations is shown in Tables I IV and Figures 2 3. When HF contacts mild steel, a corrosive reaction takes place: 2H + + 2F + Fe H 2 + FeF 2 [2] whereby scale forms on the surface of the steel and inhibits further attack of the steel (Hansen and Puyear, 1996). Since this pre-passivation technique is applied in industry by allowing the storage tanks to be corroded by HF and HF fumes for 24 hours before commissioning (Jennings, 2007), the coupons in the PICT experiments were pre-passivated to represent the starting condition of the steel used in calculating the mass loss in each case. Equation [1] was used to calculate apparent density and the nominal density of 7.85 g/cm 3 for mild steel was used throughout the study. Table I 1) A ) A t ) A t ) B Calc. A mm/a < 4.0 mm/a < mm/a Liquid corrosiveness: Decreased Therefore: A 2 < B < A 1 Susceptibility to corrosion: Decreased Table II 1) A ) A t ) A t ) B Calc. A mm/a < 7.6 mm/a < mm/a Liquid corrosiveness: Decreased Therefore: A 2 < B < A 1 Susceptibility to corrosion: Decreased VOLUME

4 Table III 1) A ) A t ) A t ) B Calc. A mm/a < 1.5 mm/a < 2.1 mm/a Liquid corrosiveness: Decreased Therefore: A 2 < B < A 1 Susceptibility to corrosion: Decreased Table IV Visual appearance of Pitting corrosion visible. Severe attack of entire sample No visible corrosion. coupons after cleaning Excessive corrosion after 8 days. surface over entire period of test. Clean surface. (Figure 7, coupon 3) (Figure 8, coupons 1 3) (Figure 9, coupons 1 4) Colour of corrosion solution Dark brown Dark brown Colourless Appearance of precipitate Light brown (FeF 2 ) Light brown (FeF 2 ) None Composition of final 38.1% HF 46.7% HF 68.6% HF corrosion solution 1.98% Fe 0.71% Fe % Fe Honeywell Fluorine Products (Honeywell International Inc., 2014) is an HF supplier that documented the properties of HF to make technical and safety-related literature openly available in order to ensure safe usage of their products. From this literature, corrosion rates for carbon steel against HF concentration were provided and reported in MILS per year (1 MIL = mm). The values for average corrosion of mild steel were converted so that apparent corrosion rates from PICT tests measured after 192 hours could be compared (Figure 4). From the corrosion tests conducted with both 40% and 48% HF, the criteria set in ASTM Standard practice G indicated that the corrosion rate for the calculated A 2 value 924 VOLUME 116

5 was smaller than the rate measured for B, and therefore the metal s susceptibility to corrosion decreased during the test. Moreover, coupon B had a smaller corrosion rate than A 1, and therefore the liquid corrosiveness also decreased. This combined situation (A 2 < B < A 1 ) indicated that the 40% and 48% HF significantly decreased in corrosiveness during the test and the formation of a partially protective scale on the steel was likely (Tables I and II). The 70% HF PICT fell under the same criteria as the 40% and 48% HF tests. However, the corrosion rates determined for A 2, B, and A1 were significantly smaller (Table II). The A 2 and B values determined for the more corrosive 48% HF (Table II) were nearly five times larger than the 0.9 and 1.5 mm/a corrosion rates determined for 70% HF under the same conditions. Therefore, the corrodibility of the metal was much lower in 70% HF than in 48% and 40% HF. Similarly, the initial corrosion rate determined for 48% HF was in excess of 180 mm/a and approximately 86 times faster than the A 1 value for the 70% HF test. Therefore, the liquid corrosiveness of 70% HF was much less than was measured for the 48% and 40% HF PICTs. Irrespective of the safety risk aspects associated with 70% HF (van der Merwe, Cornish and van der Merwe., 2016), corrosion experiments with 70% HF produced slower, more steady corrosion rates and left an adequate portion of a coupon behind (<50% mass loss) for mass loss measurements after 8 days (Figure 2) to be best relatable to what was experienced in industry. The lower the concentration of HF, the faster mild steel corrodes (Honeywell, 2002). This was shown in Figure 3. Notwithstanding that 48% HF was slightly more corrosive than 40% HF, the initial corrosion rate (over the first 24 hours) was much higher than for the 70% HF (2.1 mm/a). Thus, high corrosion rates ( mm/a) were measured for HF below 50% concentration, despite the formation of the protective fluoride (FeF 2 ) scale layer during the prepassivation step. FeF 2 is soluble in water (Perry, 2011) and since there was a higher water balance in the low-concentration acids, the scale readily dissolved and the mild steel substrate was attacked by fresh HF. However, with increased time, the scale did stabilize and the corrosion rate decreased to below 25 mm/a. The 70% HF was more conducive to scale formation on the mild steel and corrosion rates did not exceed 2 mm/a over the entire 8-day test (Figure 3). The effect of HF concentration on the corrosion rate of mild steel after 192 hours (Coupon B, Tables I III) was related to average corrosion rates reported in the Honeywell (2002) special chemical edition, where hydrofluoric acid properties were summarized (Figure 4). On average, lower HF concentrations (between 5 and 50% HF) resulted in significantly higher corrosion rates (>20 mm/a), while higher HF concentrations (>50% HF) corroded mild steel significantly slower (<2 mm/a). PICTs conducted over the HF range of 40% to 70% showed a similar trend to Honeywell (2002) (Figure 4), although the peak appeared to shift to the right, with 40% to 48% HF producing the highest corrosion rates. However, corrosion experiments at HF concentrations below 40% were not conducted, therefore this peak shift could not be substantiated. Moreover, the corrosion rates measured differed significantly as the exact corrosive conditions (initial condition of the coupons, temperature, pressure and volume of HF used) were not known and therefore could not entirely be reproduced. The corrosion solutions and coupons were observed over 8 days. Of the corrosion products (scale layer on coupons, corrosion solution and precipitates collected at the bottom of the bottle), only the corrosion solution was analysed. The coupons showed a heavily oxidized surface after prepassivation (Figure 6). Iron fluoride (FeF 2 ) has a grey colour, while the ferric hydroxide (FeF 3.3H 2 O) has a recognizable yellow-brown colour (Haynes, 2016). The black colour is characteristic of oxidation (iron II/III oxide) of the steel (Haynes, 2016), as the corrosion reaction was allowed to take place in a well ventilated bottle. A combination of all these coloured substances formed the scales on the coupon surfaces and contributed to the unique colours visible when the coupons were removed and dried after pre-passivation (Figure 6). The results in Table IV and images of the cleaned coupons after each test, differed significantly depending on the initial concentration of the HF in the corrosion solution (Figures 7 9). Pitting-type corrosion was present over the entire surface of the coupons exposed to 40% HF (Figure 7). The 48% HF resulted in a visibly more aggressive attack over the entire surface of the coupons, reminiscent of uniform corrosion. The lower iron concentration (approx. 0.7% Fe) in the 48% HF corrosion products indicated that more iron was VOLUME

6 ANDERSEN, T.N., VANORDEN, N. and SCHLITT, W.J Effects of nitrogen oxides, sulfur dioxide, and ferric ions on the corrosion of mild steel in concentrated sulfuric acid. Metallurgical Transactions A,vol. 11, no. 8. pp ASTM G 31 72, standard practice for laboratory immersion corrosion testing of metals. Annual Book of ASTM Standards. ASTM International, West Conshohocken, USA. BABOIAN, R Corrosion tests and standards: application and interpretation. ASTM International, West Conshohocken, USA. NICKEL DEVELOPMENT INSTITUTE Cleaning and descaling stainless steels. Designers Handbook Series. Toronto. CRAIG, B.D. and ANDERSON, D.S Handbook of Corrosion Data. ASM present in the solid scale layer and precipitate compared to the 40% test (approx. 2% Fe). Therefore, in the 48% HF test, the HF was forming more scale on the coupon surface which broke off and fell to the bottom of the reaction bottle, allowing HF to uniformly attack the freshly exposed steel surface and form scale to repeat the corrosion process (Figure 8). In contrast, the corrosion mechanism in the 40% HF was a visible pitting action (Figure 7), which penetrated through the passivation scale and aggressively kept corroding under the scale previously formed, resulting in the highest mass loss over the entire period (Figure 3). No scales were found at the bottom of the Teflon bottles of the 70% HF tests and the colour of the corrosion solutions remaining almost unchanged from the initial HF introduced (Table IV). The iron concentration analysed in the corrosion solution was less than 0.02%, with little HF being consumed over the entire test period (<1.5% HF). Here, the scale layer formed during the pre-passivation (Figure 9) succeeded in protecting the mild steel from further corrosion and produced a surface visibly free from corrosion, once the scale had been brushed off (Figure 9). Corrosion results on SA 516 Gr 70 normalized mild steel indicated that HF concentrations below 48% were capable of producing corrosion rates above 180 mm/a. Conversely, the steel coupons placed in 70% HF corroded significantly slower (<2 mm/a after 8 days) and the corrosion rates were more closely related to those experienced in industry. The Department of Science and Technology and the National Research Foundation are thanked for financial support. The South African Nuclear Energy Corporation Ltd. is thanked for time allowed for completing this article, as well as the Nuclear Materials (NM) and the Organic Fluorine Chemistry (OFC) sections within the Applied Chemistry (AC) department, in the Research and Development Division at Necsa, for the use of their facilities. International, Materials Park, Ohio, USA. DAVIS, J.R. and ASM INTERNATIONAL (eds) Corrosion: Understanding the Basics. ASM International, Materials Park, Ohio, USA. HANSEN, D.A. and PUYEAR, R.B Materials Selection for Hydrocarbon and Chemical Plants. CRC Press, New York, USA. HAYNES, W.M CRC Handbook of Chemistry and Physics, 94th edn. CRC Press. Honeywell Hydrofluoric acid properties. portallive/docs/1/ pdf [accessed 10 May 2016]. HONEYWELL INTERNATIONAL INC Honeywell hydrofluoric acid. [accessed 3 July 2016]. JENNINGS, H Materials for storing and handling commercial grades of aqueous hydrofluoric acid and anhydrous hydrogen fluoride (no ). NACE International Publication 5A171 (2007 edn). Houston, TX. JONES, D.A Principles and Prevention of Corrosion. 2nd edn. Prentice Hall, Upper Saddle River, NJ, USA. PERRY, D.L Handbook of Inorganic Compounds. 2nd edn. CRC Press, Sound Parkway, USA. VALKENBURG, E.G HF ISO tanks corrosion evaluation. Confidential internal report: Part 1: PCM-OPSA60-REP Pelchem SOC Ltd, Pelindaba, South Africa. VAN DER MERWE, R., CORNISH, L.A. and VAN DER MERWE, J.W Corrosion safety risk assessment for testing in hydrofluoric acid. [African Corrosion Journal, in press}. 926 VOLUME 116

Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520 Corrosion Studies on GeoBrom HG520 Vapor Space Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive

More information

Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520 Corrosion Studies on GeoBrom HG520 Total Immersion Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive

More information

Corrosion of Metals. Industrial Metallurgists, LLC Northbrook, IL Copyright 2013 Industrial Metallurgists, LLC

Corrosion of Metals. Industrial Metallurgists, LLC Northbrook, IL Copyright 2013 Industrial Metallurgists, LLC Corrosion of Metals Industrial Metallurgists, LLC Northbrook, IL 60062 847.528.3467 www.imetllc.com Copyright 2013 Industrial Metallurgists, LLC Course structure Learning modules 1. Introduction to corrosion

More information

ENGINEERING MATERIALS 65 Granada Drive Pagosa Springs, CO

ENGINEERING MATERIALS 65 Granada Drive Pagosa Springs, CO ENGINEERING MATERIALS 65 Granada Drive Pagosa Springs, CO 81147 909.260.5633 Desalination Corrosion Study Municipal Water District of Orange County Final Report Submitted To: Richard B. Bell, PE Principal

More information

W ater T alk. Field Corrosion Testing using Coupons

W ater T alk. Field Corrosion Testing using Coupons W ater T alk Field Corrosion Testing using Coupons Volume 12, Issue 1 April 2012 Most Cooling Water systems are continuously in use. Therefore it is rare to have access to inspect the actual system to

More information

TITLE: Surface Decontamination of Iron Compounds (Iron (II) Chloride (FeCl 2 )) by DeconGel TM

TITLE: Surface Decontamination of Iron Compounds (Iron (II) Chloride (FeCl 2 )) by DeconGel TM TITLE: Surface Decontamination of Iron Compounds (Iron (II) Chloride (FeCl 2 )) by DeconGel TM ABSTRACT Surface decontamination efficacy determination of DeconGel TM on stainless steel, carbon steel, aluminum

More information

Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520 Corrosion Studies on GeoBrom HG520 Partial Immersion Study a Chemtura business Great Lakes Solutions: brominated derivative products for mercury control Contents Background Information 1 Objectives 1 Executive

More information

Carbon Steel and Magnesium Oxide Dissolution for H-Canyon Process Applications

Carbon Steel and Magnesium Oxide Dissolution for H-Canyon Process Applications Carbon Steel and Magnesium Oxide Dissolution for H-Canyon Process Applications KEYWORDS: Carbon Steel Dissolution Nitric Acid Fluoride Boron Robert A. Pierce January 2004 This document was prepared in

More information

Corrosion and batteries

Corrosion and batteries Corrosion and batteries Corrosion is a process of gradual destruction of metal from its surface due to its unwanted chemical or electrochemical interaction of metal. Ore of metal which is stable and is

More information

What is: (a) aqua fortis, (b) aqua regia (c) Fixation of Nitrogen?

What is: (a) aqua fortis, (b) aqua regia (c) Fixation of Nitrogen? EXERCISE.1 Question 1: What is: (a) aqua fortis, (b) aqua regia (c) Fixation of Nitrogen? Solution 1: Book Name: Selina concise (a) Aqua fortis: Nitric acid is called aqua fortis. Aqua fortis means strong

More information

Inhibitive Influence of Carica Papaya and AzadirachtaIndica Leaves Extracts on the Corrosion of Mild Steel in H 2 SO 4 Environment.

Inhibitive Influence of Carica Papaya and AzadirachtaIndica Leaves Extracts on the Corrosion of Mild Steel in H 2 SO 4 Environment. International Journal of Engineering Inventions e-issn: 2278-7461, p-issn: 2319-6491 Volume 6, Issue 6 [June. 2017] PP: 49-57 Inhibitive Influence of Carica Papaya and AzadirachtaIndica Leaves Extracts

More information

Corrosion Resistance of Heat Exchanger Fin Materials to Potassium Hydroxide Sodium Hypochlorite-Based Cleaning Chemicals and Ammonia

Corrosion Resistance of Heat Exchanger Fin Materials to Potassium Hydroxide Sodium Hypochlorite-Based Cleaning Chemicals and Ammonia By Jeremy Olberding, Vice President of Sales, Colmac Coil Manufacturing, Inc. Corrosion Resistance of Heat Exchanger Fin Materials to Potassium Hydroxide Sodium Hypochlorite-Based Cleaning Chemicals and

More information

Technical Data Sheet. Physical Specifications. ph 6-7. Storage Requirements

Technical Data Sheet. Physical Specifications. ph 6-7. Storage Requirements AUTO / Prep DS-2 Alkaline Permanganate Desmear Process Product Description AUTO/Prep DS-2 is the second step in the AUTO/Prep Desmear-Etchback Process and is designed to remove resin smear and expose interconnects,

More information

ATI 332 ATI 332. Technical Data Sheet. Stainless Steel: Austenitic GENERAL PROPERTIES TYPICAL ANALYSIS PHYSICAL PROPERTIES

ATI 332 ATI 332. Technical Data Sheet. Stainless Steel: Austenitic GENERAL PROPERTIES TYPICAL ANALYSIS PHYSICAL PROPERTIES ATI 332 Stainless Steel: Austenitic (UNS N08800) GENERAL PROPERTIES ATI 332 alloy is a nickel and chromium austenitic stainless steel designed to resist oxidation and carburization at elevated temperatures.

More information

Accelerated Crevice Corrosion of Duplex Stainless Steels in Wet Limestone FGD Environments. Deba Maitra, Special Metals Corporation PCC Energy Group

Accelerated Crevice Corrosion of Duplex Stainless Steels in Wet Limestone FGD Environments. Deba Maitra, Special Metals Corporation PCC Energy Group Accelerated Crevice Corrosion of Duplex Stainless Steels in Wet Limestone FGD Environments Deba Maitra, Special Metals Corporation PCC Energy Group Outline General comments on alloy crevice corrosion and

More information

A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO 2 CORROSION

A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO 2 CORROSION A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO CORROSION Wei Sun, Kunal Chokshi, Srdjan Nesic, and Daniel A. Gulino Institute for Corrosion and Multiphase Technology 4 West State Street Ohio

More information

TITLE: Surface Decontamination of Zinc Compounds (Elemental Zinc Powder (Zn), Zinc Oxide (ZnO), and Zinc Acetate (Zn(O 2 CCH 3 ) 2 ) by DeconGel TM

TITLE: Surface Decontamination of Zinc Compounds (Elemental Zinc Powder (Zn), Zinc Oxide (ZnO), and Zinc Acetate (Zn(O 2 CCH 3 ) 2 ) by DeconGel TM TITLE: Surface Decontamination of Zinc Compounds (Elemental Zinc Powder (Zn), Zinc Oxide (ZnO), and Zinc Acetate (Zn(O 2 CCH 3 ) 2 ) by DeconGel TM ABSTRACT Surface decontamination efficacy determination

More information

March 28, 2019 Maintaining a Clean Brewery Presenter: Richard Rench Q&A Session

March 28, 2019 Maintaining a Clean Brewery Presenter: Richard Rench Q&A Session March 28, 2019 Maintaining a Clean Brewery Presenter: Richard Rench Q&A Session 1. Does increasing caustic solution temp above 60-70ºC no longer increase effectiveness significantly, or does it just no

More information

Nominal Composition. Weight %

Nominal Composition. Weight % HASTELLOY HYBRID-BC1 Principal Features High Resistance to Hydrochloric Acid, Sulfuric Acid, Pitting, and Crevice Corrosion HASTELLOY HYBRID-BC1 (UNS N10362) alloy possesses much higher resistance to hydrochloric

More information

SurTec 609 EC Pre-Treatment prior to E-Coat

SurTec 609 EC Pre-Treatment prior to E-Coat Protection upgraded SurTec 609 EC Pre-Treatment prior to E-Coat Properties suitable as multimetal passivation prior to painting (steel, aluminium, HDG and EG zinc and zinc die cast) yields in uniform nano-size

More information

Corrosivity of Hypobromous Acid Solutions from DBDMH and Activated HB2 Towards 304 and 316L Stainless Steel and Concrete

Corrosivity of Hypobromous Acid Solutions from DBDMH and Activated HB2 Towards 304 and 316L Stainless Steel and Concrete Corrosivity of Hypobromous Acid Solutions from DBDMH and Activated HB2 Towards 304 and 316L Stainless Steel and Concrete Jonathan Howarth Ph.D Courtney Mesrobian B.A. Enviro Tech Chemical Services, Inc.

More information

Paper No Top of the Line Corrosion in H 2 S/CO 2 Environments

Paper No Top of the Line Corrosion in H 2 S/CO 2 Environments Paper No. 08470 Top of the Line Corrosion in H 2 S/CO 2 Environments Camacho A. *, Singer M., Brown B., Nesic S. Ohio University - Institute for Corrosion and Multiphase Technology 342 West State Street,

More information

Corrosion Resistance of Alternative Reinforcing Bars: An Accelerated Test

Corrosion Resistance of Alternative Reinforcing Bars: An Accelerated Test Corrosion Resistance of Alternative Reinforcing Bars: An Accelerated Test Final Report 24 July 2006 WJE No. 2006.0773 Prepared for: CRSI Prepared by: Wiss, Janney, Elstner Associates, Inc. CORROSION RESISTANCE

More information

OXIDATION-REDUCTION TITRATIONS-Permanganometry

OXIDATION-REDUCTION TITRATIONS-Permanganometry Experiment No. Date OXIDATION-REDUCTION TITRATIONS-Permanganometry INTRODUCTION Potassium permanganate, KMnO, is probably the most widely used of all volumetric oxidizing agents. It is a powerful oxidant

More information

HYDROGEN UPTAKE RATES FOR GRADE 12 TITANIUM IN HOT ALKALINE BRINE MEDIA

HYDROGEN UPTAKE RATES FOR GRADE 12 TITANIUM IN HOT ALKALINE BRINE MEDIA HYDROGEN UPTAKE RATES FOR GRADE 12 TITANIUM IN HOT ALKALINE BRINE MEDIA J. S. Grauman & D. E. Cooper TIMET Division, Titanium Metals Corporation of America P.O. Box 2128 Henderson, NV 89015 INTRODUCTION

More information

Performance of Nickel-Coated Manganese Steel in High-Chloride Low-Sulphate Seawater Environments

Performance of Nickel-Coated Manganese Steel in High-Chloride Low-Sulphate Seawater Environments Journal of Minerals & Materials Characterization & Engineering, Vol. 9, No.10, pp.879-886, 2010 jmmce.org Printed in the USA. All rights reserved Performance of Nickel-Coated Manganese Steel in High-Chloride

More information

ROTATING CYLINDER ELECTRODE CORROSION INHIBITOR EVALUATION

ROTATING CYLINDER ELECTRODE CORROSION INHIBITOR EVALUATION XYZ COMPANY ROTATING CYLINDER ELECTRODE CORROSION INHIBITOR EVALUATION Report by: Frank Hornsby Job# 14-XXX Date: 2014 Cormetrics Ltd; #4-2280 39 th Avenue NE, Calgary, AB. T2E 6P7 Phone: 403-258-2853

More information

T 619 cm-84 TENTATIVE STANDARD 1933 OFFICIAL STANDARD 1935 CORRECTED 1944 CORRECTED 1953 CLASSICAL METHOD TAPPI. Analysis of salt cake

T 619 cm-84 TENTATIVE STANDARD 1933 OFFICIAL STANDARD 1935 CORRECTED 1944 CORRECTED 1953 CLASSICAL METHOD TAPPI. Analysis of salt cake T 619 cm-8 TENTATIVE STANDARD 19 OFFICIAL STANDARD 195 CORRECTED 19 CORRECTED 195 CLASSICAL METHOD 198 198 TAPPI The information and data contained in this document were prepared by a technical committee

More information

TITLE: Surface Decontamination of Cadmium Compounds (Cadmium Chloride (CdCl 2 ) and Cadmium Oxide (CdO)) by DeconGel TM

TITLE: Surface Decontamination of Cadmium Compounds (Cadmium Chloride (CdCl 2 ) and Cadmium Oxide (CdO)) by DeconGel TM TITLE: Surface Decontamination of Cadmium Compounds (Cadmium Chloride (CdCl 2 ) and Cadmium Oxide (CdO)) by DeconGel TM OBJECTIVE The surface decontamination efficacy determination of DeconGel TM on stainless

More information

DECOMPOSITION OF HYDRAZINE IN PRESERVED BOILERS 1

DECOMPOSITION OF HYDRAZINE IN PRESERVED BOILERS 1 DECOMPOSITION OF HYDRAZINE IN PRESERVED BOILERS 1 P.C.Mayan Kutty and T.S.Thankachan, Research & Development Center, Al Jubail Abdullah Al Ajlan and Ghazzai Al Mutairi, Laboratory Dept., SWCC Al-Jubail

More information

Review of reactor containment building corrosion events and prediction corrosion rates

Review of reactor containment building corrosion events and prediction corrosion rates Review of reactor containment building corrosion events and prediction corrosion rates Andrew Ruminski Westinghouse Electric Company Materials Center of Excellence Churchill 1 Operating Experience Non-uniform,

More information

Study on the Corrosion Kinetics of Iron in Acid and Base Medium

Study on the Corrosion Kinetics of Iron in Acid and Base Medium http://www.e-journals.net ISSN: 0973-4945; CODEN ECJHAO E- Chemistry 2011, 8(S1), S358-S362 Study on the Corrosion Kinetics of Iron in Acid and Base Medium D.B. PATIL * and A.R. SHARMA * Department of

More information

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate Version 6.2 # 187396 Description TriPass ELV 1500LT is a trivalent passivate based upon trivalent chromium, for use with electroplated zinc and

More information

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process Protection upgraded SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process (Electrolyte based on Potassium) Properties for rack and barrel plating, with excellent metal distribution good covering and throwing

More information

ATI 321 /ATI 347 /ATI 348

ATI 321 /ATI 347 /ATI 348 ATI 321 /ATI 347 /ATI 348 Stainless Steel: Austenitic (UNS S32100, S34700, S34800) GENERAL INFORMATION ATI 321 (UNS S32100), ATI 347 (UNS S34700), and ATI 348 (UNS S34800) alloys are stabilized stainless

More information

WET ANALYSIS OF GOLD-SILVER ALLOYS OF HIGH GOLD CONTENT 1

WET ANALYSIS OF GOLD-SILVER ALLOYS OF HIGH GOLD CONTENT 1 WET ANALYSIS OF GOLD-SILVER ALLOYS OF HIGH GOLD CONTENT EARLE R. CALEY AND LOWELL W. SHANK Department of Chemistry, The Ohio State University, Columbus, Ohio ABSTRACT -silver alloys dissolve completely

More information

Identification. Type Analysis

Identification. Type Analysis Page 1 of 12 Unit Display: English Print Now Custom 455 Stainless E-Mail Datasheet Add to My Materials UNS Number S45500 Identification Type Analysis Carbon 0.05 % Manganese 0.50 % Phosphorus 0.040 % Sulfur

More information

Wheel Test Method Used for Evaluation of Film-Persistent Corrosion Inhibitors for Oilfield Applications

Wheel Test Method Used for Evaluation of Film-Persistent Corrosion Inhibitors for Oilfield Applications NACE Publication 1D182 Item Number 24007 ISBN 1-57590-390-3 Approved 2017-06-01 NACE Publication 1D182 Wheel Test Method Used for Evaluation of Film-Persistent Corrosion Inhibitors for Oilfield Applications

More information

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid

Background Statement for SEMI Draft Document 5134 Revision to SEMI C , Specifications for Hydrofluoric Acid Background Statement for SEMI Draft Document 5134 Revision to SEMI C28-0306, Specifications for Hydrofluoric Acid NOTICE: This background statement is not part of the balloted item. It is provided solely

More information

Scope of Work for ELECTRO CHEMICAL POLISHING OF STAINLESS STEEL TUBES

Scope of Work for ELECTRO CHEMICAL POLISHING OF STAINLESS STEEL TUBES BHARAT HEAVY ELECTRICALS LIMITED, TIRUCHIRAPPALLI 620 014 ADVANCED TECHNOLOGY PRODUCTS Scope of Work for ELECTRO CHEMICAL POLISHING OF STAINLESS STEEL TUBES Stainless Steel Tubes of size OD17 x 2t and

More information

Copper Odyssey. Chemical Reactions of Copper

Copper Odyssey. Chemical Reactions of Copper Name Lab Partner(s) Copper Odyssey Chemical Reactions of Copper Date Period Elemental copper metal will be converted into copper (II) ion and then brought through a series of compound conversions until

More information

HASTELLOY ALLOYS: SOLUTIONS TO SEVERE WET FLUE GAS DESULFURIZATION ENVIRONMENTS

HASTELLOY ALLOYS: SOLUTIONS TO SEVERE WET FLUE GAS DESULFURIZATION ENVIRONMENTS HASTELLOY ALLOYS: SOLUTIONS TO SEVERE WET FLUE GAS DESULFURIZATION ENVIRONMENTS H. J. White Haynes International 1020 West Park A venue Kokomo, Indiana 46904-9013 HASTELLOY ALLOYS: SOLUTIONS TO SEVERE

More information

Moda 410L/4003 EN , ASTM UNS S40977

Moda 410L/4003 EN , ASTM UNS S40977 Moda 410L/4003 EN 1.4003, ASTM UNS S40977 General characteristics Moda 410L/4003 is a weldable ferritic stainless steel with elevated yield strength and resistance to abrasion. Its better corrosion resistance

More information

AL 29-4C AL 29-4C. Technical Data Sheet. Stainless Steel: Superferritic INTRODUCTION (UNS S44735)

AL 29-4C AL 29-4C. Technical Data Sheet. Stainless Steel: Superferritic INTRODUCTION (UNS S44735) AL 29-4C Stainless Steel: Superferritic (UNS S44735) INTRODUCTION AL 29-4C alloy, is a superferritic stainless steel developed by ATI in the early 1980s specifically for power plant surface condenser tubing.

More information

Stress Corrosion Study of Mild Steel in Acidic Media

Stress Corrosion Study of Mild Steel in Acidic Media Stress Corrosion Study of Mild Steel in Acidic Media M. Dauda, L. S. Kuburi, E. C. Okereke, A. A. Alabi Department of Mechanical Engineering, Ahmadu Bello University Zaria, Nigeria Abstract - The research

More information

BOMBARDIER AEROSPACE LEARJET ENGINEERING SPECIFICATION

BOMBARDIER AEROSPACE LEARJET ENGINEERING SPECIFICATION Page 1 of 11 BOMBARDIER AEROSPACE LEARJET ENGINEERING SPECIFICATION NO: TITLE: CHEMICAL CLEANING OF METALS Author: John Simon Ext. 3170 Date Req d: 8/31/00 Release Date: 09-05-000 Checked By/Group Engineer

More information

SurTec 650 chromital TCP

SurTec 650 chromital TCP Protection upgraded SurTec 650 chromital TCP Properties hexavalent chromium-free passivation for aluminium suitable as post-treatment of anodic coatings 1) suitable as conversion coating of magnesium 1)

More information

1.1. Macro-etching 1.2. Etching of a sample having multi-phases structure

1.1. Macro-etching 1.2. Etching of a sample having multi-phases structure 1. ETCHING Etching is used to highlight, and sometimes identify, microstructural features or phases present. Microscopic examination of a properly polished, unetched specimen will reveal only a few structural

More information

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning Corrosion Science 48 (2006) 2660 2675 www.elsevier.com/locate/corsci Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning Rihan Omar Rihan, Srdjan NeniT The Department of

More information

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium) SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium) Properties tolerates higher temperatures superior metal distribution produces Zn/Ni alloy deposits containing 12-15

More information

ATI 332Mo. ATI 332Mo. Technical Data Sheet. Stainless Steel: Austenitic GENERAL PROPERTIES COMPOSITION PHYSICAL PROPERTIES (UNS S35125)

ATI 332Mo. ATI 332Mo. Technical Data Sheet. Stainless Steel: Austenitic GENERAL PROPERTIES COMPOSITION PHYSICAL PROPERTIES (UNS S35125) ATI 332Mo Stainless Steel: Austenitic (UNS S35125) GENERAL PROPERTIES ATI s ATI 332Mo alloy is an austenitic stainless steel intended primarily as an economical material for automotive flexible connectors.

More information

CEL212 Environmental Engineering

CEL212 Environmental Engineering Page 1 Indian Institute of Technology Delhi CEL212 Environmental Engineering Second Semester 2012-13 (Dr. Arun Kumar; arunku@civil.iitd.ac.in) Laboratory 7: Biochemical Oxygen Demand (BOD) and Chemical

More information

RAPID MACROCELL TESTS OF ENDURAMET 2304 STAINLESS STEEL BARS

RAPID MACROCELL TESTS OF ENDURAMET 2304 STAINLESS STEEL BARS RAPID MACROCELL TESTS OF ENDURAMET 2304 STAINLESS STEEL BARS By W. Joseph Sturgeon Matthew O Reilly David Darwin JoAnn Browning A Report on Research Sponsored by TALLEY METALS Structural Engineering and

More information

THE DETERMINATION OF SPECIES IN SLAGS AND OTHER MATERIALS

THE DETERMINATION OF SPECIES IN SLAGS AND OTHER MATERIALS The Southern Ajhcan Institute of Mining and Metallurgy THE DETERMINATION OF SPECIES IN SLAGS AND OTHER MATERIALS S.M.GRAHAM G.MELLIS The determination of the oxidation state(s) of an element present in

More information

Corrosion Inhibition of Stainless Steel Using Plant Extract Vernonia amygdalina and Azadirachta indica.

Corrosion Inhibition of Stainless Steel Using Plant Extract Vernonia amygdalina and Azadirachta indica. Corrosion Inhibition of Stainless Steel Using Plant Extract Vernonia amygdalina and Azadirachta indica. O.O. Obiukwu, M.Eng.*; I.O. Opara, M.Sc.; and B.C. Oyinna, B.Sc. Department of Mechanical Engineering,

More information

Tantalum Materials in the CPI for the Next Millennium

Tantalum Materials in the CPI for the Next Millennium Tantalum Materials in the CPI for the Next Millennium Paul Aimone H.C. Starck Inc. 45 Industrial Place Newton,MA 02461 Evan Hinshaw H.C. Starck Inc. 45 Industrial Place Newton,MA 02461 ABSTRACT Tantalum

More information

Case Study: Failure Analysis of Sulfuric Acid Supply Line

Case Study: Failure Analysis of Sulfuric Acid Supply Line Case Study: Failure Analysis of Sulfuric Acid Supply Line Introduction VGO Testing & Inspection Engineers was retained by an industrial client to determine the cause of failure of a 1-inch diameter carbon

More information

TECH 50 SPECIFICATION

TECH 50 SPECIFICATION for ELECTROPOLISHED TUBING AND FITTINGS FOR USE IN HIGH PURITY PIPING SYSTEMS Current Issue: Pages not including Title Page 3 Mike Pellegrini Division VP Site Manager Jim Bundschuh Engineering and QA Manager

More information

Corrosion inhibition potential of methyl-5-benzoyl-2-benzimidazole carbamate (mebendazole) for mild steel in 1.0m sulphuric acid

Corrosion inhibition potential of methyl-5-benzoyl-2-benzimidazole carbamate (mebendazole) for mild steel in 1.0m sulphuric acid International Journal of Research in Engineering and Innovation Vol-, Issue-6 (27), 9-94 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Study of the Effectiveness of the TIG Brush Process at Cleaning and Passivating an Autogeneous TIG Weld on 316L TWI Report 23027/1/13-2 Introduction

Study of the Effectiveness of the TIG Brush Process at Cleaning and Passivating an Autogeneous TIG Weld on 316L TWI Report 23027/1/13-2 Introduction Study of the Effectiveness of the TIG Brush Process at Cleaning and Passivating an Autogeneous TIG Weld on 316L TWI Report 23027/1/13-2 1 Introduction Stainless steel products are adversely affected by

More information

A STUDY OF CAUSTIC CORROSION OF CARBON STEEL WASTE TANKS

A STUDY OF CAUSTIC CORROSION OF CARBON STEEL WASTE TANKS A STUDY OF CAUSTIC CORROSION OF CARBON STEEL WASTE TANKS C. F. Jenkins Westinghouse Savannah River Company Aiken, South Carolina, USA, 29808 ABSTRACT Solution chemistry of wastes from US atomic weapons

More information

RAPID MACROCELL TESTS OF 2205 AND XM-28 REINFORCING BARS

RAPID MACROCELL TESTS OF 2205 AND XM-28 REINFORCING BARS RAPID MACROCELL TESTS OF 2205 AND XM-28 REINFORCING BARS By Matthew O Reilly David Darwin A Report on Research Sponsored by the NEW YORK STATE DEPARTMENT OF TRANSPORTAION Structural Engineering and Engineering

More information

ONLINE MONITORING OF UNDERCOATING CORROSIONS UTILIZING COUPLED MULTIELECTRODE SENSORS. Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA ABSTRACT

ONLINE MONITORING OF UNDERCOATING CORROSIONS UTILIZING COUPLED MULTIELECTRODE SENSORS. Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA ABSTRACT ONLINE MONITORING OF UNDERCOATING CORROSIONS UTILIZING COUPLED MULTIELECTRODE SENSORS Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA ABSTRACT Online monitoring of carbon steel corrosion under different

More information

Effect of Chromium and Cobalt Additions on the Corrosion Resistance of Aluminium Silicon Iron Alloy (Al-Si- Fe)

Effect of Chromium and Cobalt Additions on the Corrosion Resistance of Aluminium Silicon Iron Alloy (Al-Si- Fe) International Journal of Scientific & Engineering Research Volume 3, Issue 12, December-2012 1 Effect of Chromium and Cobalt Additions on the Corrosion Resistance of Aluminium Silicon Iron Alloy (Al-Si-

More information

Finishing Workshop. Acid Etch Alloy Response. Introduction 5/1/2017. Acid Etch Overview. Alloy Study Weight Loss Gloss Wall Thickness.

Finishing Workshop. Acid Etch Alloy Response. Introduction 5/1/2017. Acid Etch Overview. Alloy Study Weight Loss Gloss Wall Thickness. Finishing Workshop Columbus, Ohio May 16-17, 2017 Acid Etch Alloy Response Introduction Acid Etch Overview Alloy Study Weight Loss Gloss Wall Thickness Conclusion 1 Acid Etch Overview Acid etch is an alternative

More information

Correlation between Neutral Salt Spray (NSS) Test and Potentiostat Dynamic Test for Corrosion on Zinc Plated Steel

Correlation between Neutral Salt Spray (NSS) Test and Potentiostat Dynamic Test for Corrosion on Zinc Plated Steel Correlation between Neutral Salt Spray (NSS) Test and Potentiostat Dynamic Test for Corrosion on Zinc Plated Steel Prithiviraj D [1], Rajendran R [2], Venugopal [3] Department of Mechanical Engineering,

More information

Services SAMPLE SUMMARY REPORT DR. PUMP, LLC Isuzu Rodeo. Atlanta, GA 05/24/2007

Services SAMPLE SUMMARY REPORT DR. PUMP, LLC Isuzu Rodeo. Atlanta, GA 05/24/2007 SAMPLE SUMMARY REPORT 7 Portage Trail 8.48.R 7 E A L 5.6.7 Fax:.6.7 44. 57 Report Date: 5/4/7 Primay Contact: Dr. Lev Nelik, PhD 977 Four Oaks Drive 6-75 Secondary Contact: None Provided Voice: None Provided

More information

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50 DESCRIPTION Laser EX 50 Laser EX 50 is a peroxide-based chemical polishing product that will provide a high luster on brass and most copper alloys. In many cases the Laser EX 50 will give a chemical alternative

More information

SurTec 881 Trivalent Decorative Chromium Process

SurTec 881 Trivalent Decorative Chromium Process Protection upgraded SurTec 881 Trivalent Decorative Chromium Process (Anti Salts Type) Properties environmentally friendly, hexavalent chromium free plating process high corrosion protection against calcium

More information

Issued Date: Revised September 2018 Page 1 of 5

Issued Date: Revised September 2018 Page 1 of 5 Issued Date: 01.03.2017 Revised September 2018 Page 1 of 5 1. GENERAL In order to enhance the performance of powder paint coatings on aluminium or zinc and give greatly improved corrosion resistance, it

More information

Investigation into the Effects of Microstructure on the Corrosion Susceptibility of Medium Carbon Steel

Investigation into the Effects of Microstructure on the Corrosion Susceptibility of Medium Carbon Steel The International Journal Of Engineering And Science (IJES) Volume 2 Issue 6 Pages 011-26 2013 ISSN(e): 2319 1813 ISSN(p): 2319 1805 Investigation into the Effects of Microstructure on the Corrosion Susceptibility

More information

The Effect of Final Heat Treatment and Chemical Composition. on Sensitiztation, Strength and Thermal Stability of Alloy 625. M. Kohler, U.

The Effect of Final Heat Treatment and Chemical Composition. on Sensitiztation, Strength and Thermal Stability of Alloy 625. M. Kohler, U. The Effect of Final Heat Treatment and Chemical Composition on Sensitiztation, Strength and Thermal Stability of Alloy 625 M. Kohler, U. Heubner Krupp VDM GmbH Plettenberger Str. 2, D-58791 Werdohl / Germany

More information

Corrosion Behaviour of Mild Steel in Atmospheric Exposure and Immersion tests

Corrosion Behaviour of Mild Steel in Atmospheric Exposure and Immersion tests ISSN(Online) : 2319-8753 Corrosion Behaviour of Mild Steel in Atmospheric Exposure and Immersion tests Leckraj Chamane 1, Dr. B.Y.R Surnam 2 Graduate Student, School of Mechanical Engineering, Beijing

More information

HURST CORPORATION STAINLESS STEEL

HURST CORPORATION STAINLESS STEEL STAINLESS HURST CORPORATION STEEL PRIMER www www.hurstcorp.com 2007 OVERVIEW Stainless steel is an iron-based metal which contains very low carbon levels (compared to mild steel) and various levels of

More information

THE RELATION OF OXYGEN VALUE, HEAT TINT AND PITTING CORROSION IN SUPER DUPLEX PIPE

THE RELATION OF OXYGEN VALUE, HEAT TINT AND PITTING CORROSION IN SUPER DUPLEX PIPE THE RELATION OF OXYGEN VALUE, HEAT TINT AND PITTING CORROSION IN SUPER DUPLEX PIPE Adisak Aumpiem Department of Production Engineering, Faculty of Engineering, King Mongkut s University of Technology Thonburi,

More information

Corrosion Properties of Enhanced Duplex Steel UNS S32304

Corrosion Properties of Enhanced Duplex Steel UNS S32304 A CORROSION MANAGEMENT AND APPLICATIONS ENGINEERING MAGAZINE FROM OUTOKUMPU Corrosion Properties of Enhanced Duplex Steel UNS S3234 2/215 2/215 2 Corrosion Properties of Enhanced Duplex Steel UNS S3234

More information

HASTELLOY G-30 alloy Principal Features

HASTELLOY G-30 alloy Principal Features HASTELLOY G-30 alloy Principal Features 30 years of proven performance in wet process phosphoric acid HASTELLOY G-30 alloy (UNS # N06030) is a nickel-chromium-iron material highly resistant to wet process

More information

TECHNICAL BULLETIN IMMERSION SILVER - IS150

TECHNICAL BULLETIN IMMERSION SILVER - IS150 C T Florida CirTech, Inc. 1309 North 17th Avenue Greeley, CO 80631 Telephone: (970) 346-8002 Fax: (970) 346-8331 www.floridacirtech.com TECHNICAL BULLETIN IMMERSION SILVER - IS150 I. Description This is

More information

Appendix 2 System Cleaning and Passivation Treatment

Appendix 2 System Cleaning and Passivation Treatment DNA Chromatography. Douglas T. Gjerde, Christopher P. Hanna, David Hornby Copyright c 2002 Wiley-VCH Verlag GmbH & Co. KGaA ISBNs: 3-527-30244-1 (Hardback); 3-527-60074-4 (Electronic) 207 Appendix 2 System

More information

ENVIRO/Etch Replenisher

ENVIRO/Etch Replenisher ENVIRO/Etch Replenisher Copper Etchant Product Description ENVIRO/Etch (ENVIRO/Etch) is a stabilized formulation designed to provide optimum micro-roughening and cleaning of copper surfaces prior to dry

More information

Chlorimet 2 and 3. DC2 and DC3. Bulletin A/3k

Chlorimet 2 and 3. DC2 and DC3. Bulletin A/3k Chlorimet 2 and 3 DC2 and DC3 Bulletin A/3k DC2 & DC3 Introduction Chlorimet 2 Chlorimet 2 and Chlorimet 3 are Flowserve developed Mo-Ni and Cr-Mo-Ni alloys that have been in use since the early 1950s.

More information

Technical Process Bulletin

Technical Process Bulletin Technical Process Bulletin Technical Process Bulletin No. 232971 This Revision: 19-03-2002 NOVACOAT 1100 Conversion Coating Process for Aluminum 1. Introduction: NOVACOAT 1100 is a concentrated acidic

More information

Characterization of Boiler Water from Various Industries

Characterization of Boiler Water from Various Industries Asian Journal of Chemistry Vol. 22, No. 8 (2010), 5913-5918 Characterization of Boiler Water from Various Industries FAIZA HASSAN*, TAYYABA AFTAB, TAHIRA SHAFIQUE and ABIDA MUBASSHIR Department of Chemistry,

More information

Therma 310S/4845 EN , ASTM TYPE 310S / UNS S31008

Therma 310S/4845 EN , ASTM TYPE 310S / UNS S31008 Therma 310S/4845 EN 1.4845, ASTM TYPE 310S / UNS S31008 General characteristics Austenitic heat resisting 4845 grade with very good oxidation resistance. This grade 4845 belongs to austenitic chromium-

More information

NORDTEST METHOD NT BUILD NT BUILD

NORDTEST METHOD NT BUILD NT BUILD NORDTEST METHOD NT BUILD NT BUILD 492 1 492 Approved 1999 11 1(8) CONCRETE, MORTAR AND CEMENT-BASED REPAIR MATERIALS: CHLORIDE MIGRATION COEFFICIENT FROM NON-STEADY-STATE MIGRATION EXPERIMENTS UDC 691.32/691.53/691.54

More information

Lab #7: Redox Titration Lab Exercise Chemistry II 10 points Partner: USE BLUE/BLACK INK!!!! Date: Hour:

Lab #7: Redox Titration Lab Exercise Chemistry II 10 points Partner: USE BLUE/BLACK INK!!!! Date: Hour: Lab #7: Redox Titration Lab Exercise Name: _ Chemistry II 10 points Partner: USE BLUE/BLACK INK!!!! Date: Hour: Goal: The goal of this lab is to determine the molarity of an oxalic acid solution by titrating

More information

UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER

UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER Steve Vrchota Great River Energy Elk River, MN, United States Tim Peterson Great River Energy Elk River MN,

More information

A Cycle of Copper Reactions

A Cycle of Copper Reactions EXPERIMENT A Cycle of Copper Reactions PURPOSE To demonstrate a series of copper reactions: starting with copper metal, oxidizing the metal to put it into solution and then, form a copper hydroxide, an

More information

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

Metal Finishing Products and Service META-MATE ZINCATE 40 A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS Metal Chem,inc. Metal Finishing Products and Service 29 Freedom Court Greer, SC 29650 864.877.6175 Fax 864.877.6176 DATA SHEET META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT

More information

CORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101

CORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101 CORROSION IN ACID GAS INJECTION SYSTEMS - PROJECT 101 Kevin S. Fisher, P.E. and Kenneth E. McIntush, P.E. Trimeric Corporation Buda, Texas, U.S.A. Peter F. Ellis Honeywell Corrosion Solutions Houston,

More information

KINETICS OF IRON SULFIDE AND MIXED IRON SULFIDE/CARBONATE SCALE PRECIPITATION IN CO 2 /H 2 S CORROSION

KINETICS OF IRON SULFIDE AND MIXED IRON SULFIDE/CARBONATE SCALE PRECIPITATION IN CO 2 /H 2 S CORROSION KINETICS OF IRON SULFIDE AND MIXED IRON SULFIDE/CARBONATE SCALE PRECIPITATION IN CO 2 /H 2 S CORROSION Wei Sun and Srdjan Nesic Institute for Corrosion and Multiphase Technology Ohio University 342 West

More information

Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts 1

Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts 1 Designation: A 967 01 e1 Standard Specification for Chemical Passivation Treatments for Stainless Steel Parts 1 This standard is issued under the fixed designation A 967; the number immediately following

More information

SEALER 300 W CT. Clear colourless liquid

SEALER 300 W CT. Clear colourless liquid SEALER 300 W CT PHYSICAL PROPERTIES: Clear colourless liquid DESCRIPTION: SEALER 300 W CT is a water dilutable, inorganic sealing system based on silicon. SEALER 300 W CT contains no chromates in the dry

More information

Kraft Liquor Corrosion

Kraft Liquor Corrosion Pulp and Paper Corrosion Symposium Georgia Tech Renewable Bioproducts Institute November 2014 Kraft Liquor Corrosion Margaret Gorog Federal Way, WA Topics Brown Stock Corrosion Alkaline Liquor Corrosion

More information

WHAT IS THE ACTUAL COST OF YOUR COMMERCIAL WATER HEATER? LOOKING BEYOND EFFICIENCY INCREASING ROI THROUGH WATER HEATER MATERIAL SELECTION

WHAT IS THE ACTUAL COST OF YOUR COMMERCIAL WATER HEATER? LOOKING BEYOND EFFICIENCY INCREASING ROI THROUGH WATER HEATER MATERIAL SELECTION Engineered Water Heating Solutions WHAT IS THE ACTUAL COST OF YOUR COMMERCIAL WATER HEATER? LOOKING BEYOND EFFICIENCY INCREASING ROI THROUGH WATER HEATER MATERIAL SELECTION Water Heater Efficiency Water

More information

Standard Recommended Practice

Standard Recommended Practice NACE Standard RP0205-2005 Item No. 21107 Standard Recommended Practice Recommended Practice for the Design, Fabrication, and Inspection of Tanks for the Storage of Petroleum Refining Alkylation Unit Spent

More information

Corrosion of Electrical Submersible Pumps (ESP) In South Rumaila Oil Field

Corrosion of Electrical Submersible Pumps (ESP) In South Rumaila Oil Field Iraqi Journal of Chemical and Petroleum Engineering Iraqi Journal of Chemical and Petroleum Engineering Vol.16 No.1 (March 2015) 63-69 ISSN: 1997-4884 University of Baghdad College of Engineering Corrosion

More information

SULFIDATION. From Rolled Alloys Report Number 94-72

SULFIDATION. From Rolled Alloys Report Number 94-72 SULFIDATION Environments containing sulfur may rapidly attack high nickel alloys. The problem is more severe under reducing, or low oxygen, environments. The higher the nickel the more sensitive the alloy

More information

RECOVERY OF GERMANIUM FROM LEAD BLAST FURNACE SLAG

RECOVERY OF GERMANIUM FROM LEAD BLAST FURNACE SLAG RECOVERY OF GERMANIUM FROM LEAD BLAST FURNACE SLAG Hakan Cengizler 1 and R Hurman Eric 2 1 Celal Bayar University, TMYO, Turgutlu - Turkey 2 University of the Witwatersrand, Johannesburg, School of Chemical

More information

Back to Basics Stainless Steel. Tom Mackerras National Engineering Manager

Back to Basics Stainless Steel. Tom Mackerras National Engineering Manager Back to Basics Stainless Steel Tom Mackerras National Engineering Manager Winery Engineers Conference 2018 26 July 2018 1 What is Stainless Steel? Group of steels which have a minimum of 10.5% Cr Creates

More information